1 Inductive positioning system PMI14V-F112

Inductive positioning system
PMI14V-F112-2EPE2-IO-V15
Technical data
General specifications
Installation
Object distance
Adjustment range
Nominal ratings
Operating voltage UB
Reverse polarity protection
Linearity error
Repeat accuracy
Resolution
Temperature drift
No-load supply current I0
Operating voltage indicator
Interface
Interface type
Mode
Value range
Switching output
Output type
Model Number
PMI14V-F112-2EPE2-IO-V15
Features
• Parameterization and diagnosis
via IO-Link
• 3 configurable switching frames
flush
max. 2.5 mm
0 ... 14 mm
10 ... 30 V
reverse polarity protected
± 0.3 mm
± 0.05 mm
33 µm
± 0.5 mm
≤ 20 mA
LED green
IO-Link
COM 2 (38.4 kBaud)
0000h ... 7000h
2 Push-pull (4 in 1) outputs , 1 switch output PNP , shortcircuit protected , reverse polarity protected , overvoltage
protected , programmable
≤ 100 mA
3-step, adjustable 0.2 m ... 0.8 mm
≤3V
pulsing
Operating current IL
Switching hysteresis
Voltage drop
Short-circuit protection
Ambient conditions
Ambient temperature
Mechanical specifications
Connection type
Housing material
Protection degree
Material
Target
Note
-25 ... 70 °C (-13 ... 158 °F)
5-pin, M12 x 1 connector
PA 66
IP67
Steel ST37 / 1.0037
The data relating to accuracy only apply to a distance to the
object to be detected of 1 ... 2.5 mm.
Compliance with standards and
directives
Standard conformity
Standards
EN 60947-5-2:2007
IEC 60947-5-2:2007
Approvals and certificates
UL approval
cULus Listed, General Purpose, Class 2 Power Source
CCC approval
CCC approval / marking not required for products rated
≤36 V
Dimensions
LED
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Pepperl+Fuchs Group
USA: +1 330 486 0001
Germany: +49 621 776 4411
fa-info@de.pepperl-fuchs.com
www.pepperl-fuchs.com
fa-info@us.pepperl-fuchs.com
44
20
30.5
M12 x 1
14
25
15
2 x ø 4.3
35
Release date: 2013-12-11 15:41 Date of issue: 2013-12-11 244396_eng.xml
25
35
Singapore: +65 6779 9091
fa-info@sg.pepperl-fuchs.com
1
Inductive positioning system
PMI14V-F112-2EPE2-IO-V15
Additional Information
Electrical Connection
1
≥1
L+
4
8
≥4
8
C/Q1
5
Q3
2
Q2
3
L-
Pinout
1
5
4
2
3
Wire colors in accordance with EN 60947-5-2
(brown)
(white)
(blue)
(black)
(gray)
10
BN
WH
BU
BK
GY
≥
1
2
3
4
5
Accessories
V15-G-2M-PVC
Female cordset, M12, 5-pin, PVC cable
V15-W-2M-PVC
Female cordset, M12, 5-pin, PVC cable
BT-F90-W
Damping element; lateral screw holes
IO-Link-Master01-USB
IO-Link master, supply via USB port or separate power supply, LED indicators, M12
plug for sensor connection
≤ 2.5
IO-Link-Master-USB DTM
Communication DTM for use of IO-Link-Master
Release date: 2013-12-11 15:41 Date of issue: 2013-12-11 244396_eng.xml
Description of Sensor Functions
Additional Functions and Parameters (IO-Link)
Additional functions
Sensor temperature indicator
Measuring range overrun and underrun indicator
Measuring range
Scalable measuring range
Invertible measuring range
Switching outputs
Switching point can be parameterized/taught in
Switching window can be parameterized/taught in
Switching hysteresis can be parameterized
Invertible switching output
Selectable output type (high or low switched)
2
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Pepperl+Fuchs Group
USA: +1 330 486 0001
Germany: +49 621 776 4411
fa-info@de.pepperl-fuchs.com
www.pepperl-fuchs.com
fa-info@us.pepperl-fuchs.com
Singapore: +65 6779 9091
fa-info@sg.pepperl-fuchs.com
Inductive positioning system
PMI14V-F112-2EPE2-IO-V15
Information on Installation and Operation
Safety Information
This product must not be used in applications in which the safety of persons depends on the function of the device.
This product is not a safety component as specified in the EU Machinery Directive.
Warnung
Actuator
The linear position measurement system is optimally aligned to the geometry of Pepperl+Fuchs actuators.
Using Your Own Actuators
Generally speaking, it is possible for you to use your own actuators. The specified measurement accuracy of the sensor will be achieved
only if the actuator has the following properties:
• Material: construction steel such as S235JR+AR (previously St37)
• Dimensions (L x W x H): > 18 mm x 8 mm x > 4 mm
• The active surface of the actuator must protrude across the entire sensor width.
Note:
The width of the actuator must be precisely 8 mm. If the width of the actuator deviates from this value, the position values will differ.
Installation
• It is possible to flush mount the device.
• The distance between the center of the measurement field (framed area on the front panel of the sensor) and the fixing base or fixing
elements (e.g., protruding screw heads) of the actuator must be at least 10 mm.
Operating Instructions
The specified measurement accuracy is achieved if the distance of the actuator from the sensor surface is max. 2.5 mm.
Definition of the Measuring Range/Measured Position
The measured position of the actuator is based on half of the width (center of the actuator).
The measuring range starts and ends when the actuator covers the measurement field marked on the sensor with half of its width in the
course of its longitudinal movement.
start of measuring range
measured position
end of measuring range
w/2
width w of actuator
labeled measuring area
actuator
Release date: 2013-12-11 15:41 Date of issue: 2013-12-11 244396_eng.xml
motion direction of actuator
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Pepperl+Fuchs Group
USA: +1 330 486 0001
Germany: +49 621 776 4411
fa-info@de.pepperl-fuchs.com
www.pepperl-fuchs.com
fa-info@us.pepperl-fuchs.com
Singapore: +65 6779 9091
fa-info@sg.pepperl-fuchs.com
3
Inductive positioning system
PMI14V-F112-2EPE2-IO-V15
Supported IO-Link device parameters
Index
Subindex
Name
Smart sensor profile parameters
0x3A
Teach-In Channel
0x3B
Teach-In Status
0x3C
1, 2
0x3D
1, 2, 3
BD1_SPV, Switching signal 1
BD1_SPV, Switching signal 1 configuration
0x3E
1, 2
BD2_SPV, Switching signal 2
0x3F
1, 2, 3
BD2_SPV, Switching signal 2 configuration
0x4000
1, 2
BD3_SPV, Switching signal 3
0x4001
1, 2, 3
BD3_SPV, Switching signal 3 configuration
Device specific operation parameters
0x40
1, 2, 3
Centered Window Width
0x42
1, 2
AD_SPC, Analog signal setpoint value
0x43
1, 2, 3
AD_SPC, Analog signal configuration
0x5F
1, 2, 3, 4, 5
Measurement data collection
Standard operation control
0x70
1, 2, 3, 4, 5, 6, 7, 8
Output configuration
0x74
Event configuration
0x7F
Locator indication control
User information
0xC0
UT1, User tag 1
0xC1
UT2, User tag 2
Special function
0xE2
0xE8
Operating temperature
1, 2
Device characteristics
Release date: 2013-12-11 15:41 Date of issue: 2013-12-11 244396_eng.xml
Details of the listed device parameters can be found in the manual.
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Pepperl+Fuchs Group
USA: +1 330 486 0001
Germany: +49 621 776 4411
fa-info@de.pepperl-fuchs.com
www.pepperl-fuchs.com
fa-info@us.pepperl-fuchs.com
Singapore: +65 6779 9091
fa-info@sg.pepperl-fuchs.com
4
Open as PDF
Similar pages