STANDBY GENERATORS
17 kW
Air-Cooled Gas Engine Generator Sets
Includes:
• True Power® Electrical Technology
• Two Line LCD Digital Controller
Continuous Standby Power Rating
Model 05504 (Steel - Bisque) - 17 kW 60Hz
Model 05505 (Aluminum - Gray) - 17 kW 60Hz
•A
utomatic Transfer Switch
with Built-In Priority Load Center
• Electronic Governor
• Pre-wired External Connection Box
•E
xternal Main Circuit Breaker,
System Status & Maintenance Interval LED's
and GFCI Duplex Outlet
• Flexible Fuel Line Connector
• Composite Mounting Pad
• Pre-wired conduits
• Natural Gas or LP Gas Operation
• UL 2200 Listed
FEATURES
¡INNOVATIVE DESIGN & PROTOTYPE TESTING are key components
of GENERAC’S success in “IMPROVING POWER BY DESIGN.”
But it doesn’t stop there. Total commitment to component testing,
reliability testing, environmental testing, destruction and life testing,
plus testing to applicable CSA, NEMA, EGSA, and other standards,
allows you to choose GENERAC POWER SYSTEMS with the
confidence that these systems will provide superior performance.
¡ T RUE POWER® ELECTRICAL TECHNOLOGY: Superior harmonics
and sine wave form produce less than 5% Total Harmonic Distortion for
utility quality power. This allows confident operation of sensitive electronic
equipment and micro-chip based appliances, such as variable speed HVAC.
¡ TEST CRITERIA:

PROTOTYPE TESTED
 SYSTEM TORSIONAL TESTED
 NEMA MG1-22 EVALUATION
 MOTOR STARTING ABILITY
¡SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION.
This state-of-the-art power maximizing regulation system is standard on
all Generac models. It provides optimized FAST RESPONSE to changing
load conditions and MAXIMUM MOTOR STARTING CAPABILITY by
electronically torque-matching the surge loads to the engine.
¡SINGLE SOURCE SERVICE RESPONSE from Generac’s dealer network
provides parts and service know-how for the entire unit, from the engine
to the smallest electronic component. You are never on your own when
you own a GENERAC POWER SYSTEM.
¡GENERAC TRANSFER SWITCHES. Long life and reliability are
synonymous with GENERAC POWER SYSTEMS. One reason for this
confidence is that the GENERAC product line includes its own transfer
systems and controls for total system compatibility.
INSTALLATION
SYSTEM
UNIT
CONTROLS
TRANSFER
SWITCH
GENERATOR
ENGINE
SPECIFICATIONS Home Standby - 17 kW
•Generac (OHVI) Design
Maximizes engine “breathing” for increased fuel efficiency. Plateau honed cylinder walls and plasma
molly rings help engine run cooler, reducing oil consumption. Because heat is the primary cause of
engine wear, the OHVI has a significantly longer life than competitive engines.
•”Spiny-lok” cast iron cylinder walls
Rigid construction and added durability provide long engine life. ,
•Electronic ignition, spark advance and
compression release
These features combine to assure smooth, quick starting every time.
•Full pressure lubrication system
Superior lubrication to all vital bearings means better performance, less maintenance and
significantly longer engine life. Now featuring a 2 year/200 hour oil change interval.
•Low oil pressure shutdown system
Superior shutdown protection prevents catastrophic engine damage due to low oil.
•High temperature shutdown
Prevents damage due to overheating.
•Revolving field
Allows for smaller, light weight unit that operates 25% more efficiently than a revolving armature generator.
•Skewed stator
Produces a smooth output waveform for compatibility with electronic equipment.
•Displaced phase excitation
Maximizes motor starting capability. Provides more surge capability than brushless generator designs.
•Automatic voltage regulation
Regulates the output voltage to ±2% prevents damaging voltage spikes.
•UL 2200 Listed
For your safety
•Fully Automatic
Transfers your vital electrical loads to the energized source of power.
•Remote Mounting
Mounts near your existing distribution panel for simple, low cost installation.
•UL Listed
For your safety-
•Manual/Auto/Off switch
Selects the operating mode.
•Utility voltage sensing
Constantly monitors utility voltage, setpoints 65% dropout, 75% pick-up, of standard voltage.
•Utility interrupt delay
Prevents nuisance start-ups of the engine, adjustable 10-30 seconds.
•Engine warm-up
Ensures engine is ready to assume the load, setpoint approximately 10 seconds.
•Engine cool-down
Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
•Seven day exerciser
Operates engine to prevent oil seal drying and damage between power outages.
•Timed Trickle Battery charger
Maintains battery amperage to insure starting.
•Main Line Circuit Breaker
Protects generator from overload.
•Weather protective enclosure
Ensures protection against mother nature. Hinged key locking roof panel for security.
Lift-out front for easy access to all routine maintenance items. Electrostatically applied
textured epoxy paint for added durability. Model 05505 has an aluminum enclosure.
•Enclosed critical grade muffler
Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
•Small, compact, attractive
Makes for an easy, eye appealing installation.
•Pre-wired External Connection Box
Easy Installation - Virtually all hardware included, plus step-by-step photographed Installation Guide.
•1’ Flexible Fuel Line Connector
•Composite Mounting Pad
•Pre-wired conduits
•UL Listed wire nuts
Home Standby - 17 kW
GENERATOR
Rated Maximum Continuous Power Capacity (LP)
Rated Maximum Continuous Power Capacity (NG)
Rated Voltage
Rated Maximum Continuous Load Current
120 Volts
240 Volts
Total Harmonic Distortion
Main Line Circuit Breaker
Phase
Number of Rotor Poles
Rated AC Frequency
Power Factor
Battery Requirement (not included)
Unit Weight
Dimensions (L” x W” x H”)
Sound output in dB(A) at 23 ft. with generator operating at normal load
Sound output in dB(A) at 23 ft. with generator in Whisper-Test™ low speed exercise mode
Model 05504 (17 kW)
Model 05505 (17 kW)
17,000 Watts*
16,000 Watts*
120/240
17,000 Watts*
16,000 Watts*
120/240
141.6 LP/133.3 NG
70.8 LP/66.6 NG
Less than 5%
65 Amp
1
2
60Hz
1
Group 26
12 Volts and
525 Cold-cranking
Amperes Minimum
445 Pounds
48 x 25 x 29
66
60
141.6 LP/133.3 NG
70.8 LP/66.6 NG
Less than 5%
65 Amp
1
2
60Hz
1
Group 26
12 Volts and
525 Cold-cranking
Amperes Minimum
414 Pounds
48 x 25 x 29
66
60
ENGINE
Model 05504 (17 kW)
Model 05505 (17 kW)
Type of Engine
Number of Cylinders
Rated Horsepower
Displacement
Cylinder Block
GENERAC OHVI V-TWIN
2
32 @ 3,600 rpm
992cc
Aluminum w/Cast
Iron Sleeve
Overhead Valve
Solid-state w/Magneto
Electronic
9.5:1
12 Vdc
Approx. 1.7 Qts.
3,600
GENERAC OHVI V-TWIN
2
32 @ 3,600 rpm
992cc
Aluminum w/Cast
Iron Sleeve
Overhead Valve
Solid-state w/Magneto
Electronic
9.5:1
12 Vdc
Approx. 1.7 Qts.
3,600
Valve Arrangement
Ignition System
Governor System
Compression Ratio
Starter
Oil Capacity Including Filter
Operating RPM
Fuel Consumption
Natural Gas cu.ft./hr.
1/2 Load
183
183
Full Load
261
261
Liquid Propane
ft3/hr (gal/hr)
1/2 Load
59 (1.61)
59 (1.61)
Full Load
94 (2.57)
94 (2.57)
Required fuel pressure to generator fuel inlet at all load ranges - 5 to 7 inches of water column for natural gas, 11 to 14 inches of water column for LP gas
CONTROLS
2-Line Plain Text LCD Display
Mode Switch
-Auto
-Off
-Manual/Test (start)
Engine Start Sequence
Engine Warm-up
Engine Cool-Down
Starter Lock-out
2.5 Amp Timed Trickle Battery Charger
Automatic Voltage Regulator w/Overvoltage Protection
Automatic Low Oil Pressure Shutdown
Overspeed Shutdown
High Temperature Shutdown
Overcrank Protection
Safety Fuse
Simple user interface for ease of operation
Automatic Start on Utility failure. 7 day exerciser
Stops unit. Power is removed. Control and charger still operate.
Start with starter control, unit stays on. If utility fails, transfer to load takes place.
Cyclic cranking: 7 sec. on, 7 rest (90 sec. maximum duration)
10 seconds
1 minute
Starter cannot re-engage until 5 sec. after engine has stopped.
Standard
Standard
Standard
Standard, 72Hz
Standard
Standard
Standard
Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with
BS5514, ISO3046 and DIN6271). * Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc. Maximum
power decreases about 3.5 percent for each 1,000 feet above sea level; and also will decrease about 1 percent for each 12° C (10° F) above 15.5° C (60°F).
Home Standby - 17 kW
TRANSFER SWITCH & PRIORITY LOAD CENTER
No. of Poles
Current Rating (amps)
Voltage Rating (VAC)
Utility Voltage Monitor (fixed)
-Pick-up
-Dropout
Return to Utility
Exerciser weekly for 12 minutes
UL Listed
Dimensions (H” x W” x D”)
Total of Pre-wired Circuits
No. 15A 120V
No. 20A 120V
No. 20A 240V
No. 40A 240V
W2
No. 50A 240V
Circuit Breaker Protected
Available RMS Symmetrical
Fault Current @ 250 Volts
Model 05504 (17 kW)
Model 05505 (17 kW)
2
100
250
2
100
250
75%
65%
approx. 13 sec.
Standard
Standard
26.5 x 12.5 x 7
16
5
5
1
1
1
75%
65%
approx. 13 sec.
Standard
Standard
26.5 x 12.5 x 7
16
5
5
1
1
1
10,000
10,000
H2
H1
Mechanical Dimensions (in inches)
Height
Current
No. of
H1
Rating
Poles
H1
H2
100 UL Listed
2
26.5
29.25
W2
H2
Width
W1
8.14
• Electrically operated,
mechanically-held contacts for
fast, positive connections.
• Rated for all classes of load,
100% equipment rated, both
inductive and resistive.
• 2 pole, 250 VAC contactors.
• 160 millisecond transfer time.
• Dual coil design.
• Main contacts are silver plated
or silver alloy to resist welding
and sticking.
Depth
W2
12.5
Transfer Switch Features
• NEMA 1 (indoor rated)
enclosure is standard on the 100
amp switch.
7
H2
Terminal Wire Ranges
ATS Rated Amps
Switch Terminal
100A 2-Pole UL
1 x 1/0-12
H1
W1
H1
H2
Neutral Lug/Stud
1 x 3/8-16 Stud
Ground Lug
1 x 2/0-14
W1
W2
TRANSFER
SWITCH
8KW - 17KW
(IF SUPPLIED)
TRANSFER
SWITCH
20KW
(IF SUPPLIED)
W1
W1
W2
Design and specifications subject to change without notice. Dimensions shown are approximate. Contact your Generac dealer for certified drawings. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES.
TRANSFER
SWITCH
8KW - 17KW 637.6
[25.1]
(IF SUPPLIED)
731.9
[28.8]
731.9
[28.8]
TRANSFER
SWITCH
20KW
(IF SUPPLIED)
637.6
[25.1]
642
[25.3]
1218
[47.9]
1218
[47.9]
76.2 [3.0]
PEA GRAVEL
MINIMUM
LEFT SIDE VIEW
1226
[48.3]
FRONT VIEW
GENERAC POWER SYSTEMS, INC. • P.O. BOX 297 • WHITEWATER, WI
642
WEBSITE: www.guardiangenerators.com
76.2 [3.0]
[25.3]
1226
Bulletin 0176760SBY / Printed in U.S.A. 03.08
LEFT SIDE VIEW
PEA GRAVEL
MINIMUM
© 2008
[48.3]
53190
Generac Power Systems, Inc. All rights reserved.All specifications are subject to change without notice.
FRONT VIEW
Open as PDF