D-Link DGS-3426 network switch User manual

Add to my manuals
246 Pages

advertisement

D-Link DGS-3426 network switch User manual | Manualzz

User Manual

TM

Product Model: DGS-3400 Series

Layer 2 Gigabit Managed Switch

Release 1

©Copyright 2005. All rights reserved.

xStack DGS-3400 Series Fast Ethernet Switch

______________________________________________

Information in this document is subject to change without notice.

© 2005 D-Link Computer Corporation. All rights reserved.

Reproduction in any manner whatsoever without the written permission of D-Link Computer Corporation is strictly forbidden.

Trademarks used in this text: D-Link and the D-LINK logo are trademarks of D-Link Computer Corporation; Microsoft and Windows are registered trademarks of Microsoft Corporation.

Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. D-Link

Computer Corporation disclaims any proprietary interest in trademarks and trade names other than its own.

December 2005 P/N 651GS3400015G ii

Table of Contents

Intended Readers ............................................................................................................................................................. viii

Typographical Conventions............................................................................................................................................................ viii

Notes, Notices, and Cautions........................................................................................................................................... viii

Safety Instructions..............................................................................................................................................................ix

Safety Cautions................................................................................................................................................................................. ix

General Precautions for Rack-Mountable Products ........................................................................................................................... x

Protecting Against Electrostatic Discharge....................................................................................................................................... xi

Introduction............................................................................................................................................ 1

Switch Description ....................................................................................................................................................................... 1

Features.............................................................................................................................................................................................. 2

Ports................................................................................................................................................................................................... 3

Front-Panel Components .............................................................................................................................................................. 4

LED Indicators .................................................................................................................................................................................. 5

Rear Panel Description ................................................................................................................................................................. 7

Side Panel Description ................................................................................................................................................................. 8

Installation .............................................................................................................................................. 9

Package Contents ......................................................................................................................................................................... 9

Installation Guidelines.................................................................................................................................................................. 9

Installing the Switch without the Rack ....................................................................................................................................... 10

Installing the Switch in a Rack ................................................................................................................................................... 10

Mounting the Switch in a Standard 19" Rack............................................................................................................................. 11

Power On ......................................................................................................................................................................................... 11

Power Failure ............................................................................................................................................................................. 11

Installing the SFP ports .............................................................................................................................................................. 12

The Optional Module ................................................................................................................................................................. 13

Install the Module....................................................................................................................................................................... 14

External Redundant Power System.................................................................................................................................................. 15

Connecting the Switch ......................................................................................................................... 17

Switch to End Node.................................................................................................................................................................... 17

Switch to Switch......................................................................................................................................................................... 17

Connecting To Network Backbone or Server .................................................................................................................................. 17

Introduction to Switch Management.................................................................................................. 18

Management Options.................................................................................................................................................................. 18

Connecting the Console Port (RS-232 DCE).............................................................................................................................. 19

Managing the Switch for the First Time..................................................................................................................................... 20

Password Protection ................................................................................................................................................................... 22

IP Address Assignment .............................................................................................................................................................. 24

Web-based Switch Configuration....................................................................................................... 26

Introduction .......................................................................................................................................................................26

Logging in to the Web Manager ...................................................................................................................................................... 27

Web-based User Interface................................................................................................................................................................ 28

Areas of the User Interface......................................................................................................................................................... 28

Web Pages ....................................................................................................................................................................................... 29

Configuring the Switch........................................................................................................................ 30

Device Information.......................................................................................................................................................................... 30

IP Address ....................................................................................................................................................................................... 33

Setting the Switch's IP Address using the Console Interface...................................................................................................... 34

Port Configuration ........................................................................................................................................................................... 35

Port Description.......................................................................................................................................................................... 36

User Accounts.................................................................................................................................................................................. 37

Port Mirroring.................................................................................................................................................................................. 38

System Log Host ............................................................................................................................................................................. 39

System Severity Settings ............................................................................................................................................................ 41

SNTP Settings.................................................................................................................................................................................. 42

Time Settings.............................................................................................................................................................................. 42

Time Zone and DST ................................................................................................................................................................... 43

MAC Notification Settings .............................................................................................................................................................. 45

Global Settings ........................................................................................................................................................................... 45

Port Settings ............................................................................................................................................................................... 45

TFTP Services ................................................................................................................................................................................. 46

Multiple Image Services .................................................................................................................................................................. 47

Firmware Information ................................................................................................................................................................ 47

Ping Test.......................................................................................................................................................................................... 48

Safeguard Engine............................................................................................................................................................................. 48

Static ARP Settings.......................................................................................................................................................................... 51

Static IPv6 ARP Settings............................................................................................................................................................ 52

Routing Table .................................................................................................................................................................................. 53

Static/Default IP Route Settings ................................................................................................................................................. 53

Static IPv6 Route Settings ............................................................................................................................................................... 55

DHCP Auto Configuration Settings ........................................................................................................................................... 56

SNMP Settings ................................................................................................................................................................................ 57

SNMP User Table ...................................................................................................................................................................... 58

SNMP View Table ..................................................................................................................................................................... 59

SNMP Group Table.................................................................................................................................................................... 60

SNMP Community Table Configuration.................................................................................................................................... 62

SNMP Host Table ...................................................................................................................................................................... 64

SNMP Engine ID........................................................................................................................................................................ 65

IP-MAC Binding ............................................................................................................................................................................. 66

IP-MAC Binding per Port .......................................................................................................................................................... 66

IP-MAC Binding Table .............................................................................................................................................................. 67

IP-MAC Binding Blocked.......................................................................................................................................................... 67

Single IP Management (SIM) Overview ...........................................................................................................................68

SIM Using the Web Interface..................................................................................................................................................... 70

Topology.......................................................................................................................................................................................... 71

Tool Tips .................................................................................................................................................................................... 73

Menu Bar.................................................................................................................................................................................... 77

Single IP Management Firmware Upgrade...................................................................................................................................... 78

Single IP Management Configuration File Backup/Restore ....................................................................................................... 79

Single IP Management Log Files ............................................................................................................................................... 79

Layer 2 Features................................................................................................................................... 80

VLANs ..............................................................................................................................................................................80

Understanding IEEE 802.1p Priority .......................................................................................................................................... 80

VLAN Description........................................................................................................................................................................... 80

Notes about VLANs on the DGS-3400 Series............................................................................................................................ 81

IEEE 802.1Q VLANs ...................................................................................................................................................................... 81

802.1Q VLAN Tags ................................................................................................................................................................... 82

Port VLAN ID............................................................................................................................................................................ 83

Tagging and Untagging .............................................................................................................................................................. 83

Ingress Filtering.......................................................................................................................................................................... 84

Default VLANs .......................................................................................................................................................................... 84

Port-based VLANs ..................................................................................................................................................................... 85

VLAN Segmentation.................................................................................................................................................................. 85

VLAN and Trunk Groups........................................................................................................................................................... 85

Static VLAN Entry .......................................................................................................................................................................... 85

GVRP Setting .................................................................................................................................................................................. 88

Trunking .......................................................................................................................................................................................... 90

Understanding Port Trunk Groups.............................................................................................................................................. 90

Link Aggregation............................................................................................................................................................................. 91

LACP Port Setting ........................................................................................................................................................................... 93

IGMP ............................................................................................................................................................................................... 94

IGMP Snooping............................................................................................................................................................................... 94

Static Router Ports Entry ................................................................................................................................................................. 95

Spanning Tree ...................................................................................................................................................................97

802.1s MSTP.............................................................................................................................................................................. 97

802.1w Rapid Spanning Tree ..................................................................................................................................................... 97

Port Transition States ................................................................................................................................................................. 97

Edge Port.................................................................................................................................................................................... 98

P2P Port...................................................................................................................................................................................... 98

802.1d/802.1w/802.1s Compatibility ......................................................................................................................................... 98

STP Bridge Global Settings........................................................................................................................................................ 99

MST Configuration Identification ................................................................................................................................................. 102

MSTP Port Information ................................................................................................................................................................. 105

STP Instance Settings .................................................................................................................................................................... 106

STP Port Settings........................................................................................................................................................................... 107

Forwarding & Filtering ...................................................................................................................................................109

Unicast Forwarding .................................................................................................................................................................. 109

Static Multicast Forwarding ..................................................................................................................................................... 109

Multicast Filtering Mode.......................................................................................................................................................... 110

QoS..................................................................................................................................................................................112

The Advantages of QoS................................................................................................................................................................. 112

Understanding QoS........................................................................................................................................................................ 113

Bandwidth Control......................................................................................................................................................................... 114

QoS Scheduling Mechanism.......................................................................................................................................................... 115

QoS Output Scheduling ................................................................................................................................................................. 116

Configuring the Combination Queue........................................................................................................................................ 117

802.1p Default Priority .................................................................................................................................................................. 118

802.1p User Priority....................................................................................................................................................................... 119

Access Profile Table........................................................................................................................................................120

Configuring the Access Profile Table....................................................................................................................................... 120

CPU Interface Filtering.................................................................................................................................................................. 131

CPU Interface Filtering State Settings...................................................................................................................................... 131

CPU Interface Filtering Table .................................................................................................................................................. 132

Security ............................................................................................................................................... 142

Traffic Control............................................................................................................................................................................... 143

Port Security............................................................................................................................................................................. 146

Port Lock Entries ........................................................................................................................................................................... 147

Configure 802.1x Authenticator .................................................................................................................................................... 148

RADIUS Server............................................................................................................................................................................. 150

Trusted Host .................................................................................................................................................................................. 151

Access Authentication Control ...................................................................................................................................................... 152

Authentication Policy & Parameters.............................................................................................................................................. 153

Application's Authentication Settings............................................................................................................................................ 153

Authentication Server Group.................................................................................................................................................... 154

Authentication Server Host ...................................................................................................................................................... 155

Login Method Lists .................................................................................................................................................................. 156

Enable Method Lists................................................................................................................................................................. 158

Local Enable Password............................................................................................................................................................. 160

Enable Admin........................................................................................................................................................................... 160

Traffic Segmentation ..................................................................................................................................................................... 161

Secure Socket Layer (SSL) .............................................................................................................................................162

Download Certificate..................................................................................................................................................................... 162

SSL Configuration ......................................................................................................................................................................... 163

Secure Shell (SSH)..........................................................................................................................................................165

SSH Configuration......................................................................................................................................................................... 165

SSH Algorithm......................................................................................................................................................................... 166

SSH User Authentication Mode..................................................................................................................................................... 168

Save, Reset and Reboot...................................................................................................................... 169

Save Changes ..................................................................................................................................................................169

Reset................................................................................................................................................................................170

Reboot System.................................................................................................................................................................170

Logout .............................................................................................................................................................................170

Monitoring .......................................................................................................................................... 171

Device Status............................................................................................................................................................................ 172

Module Information.................................................................................................................................................................. 172

CPU Utilization ........................................................................................................................................................................ 173

Port Utilization ......................................................................................................................................................................... 174

Packets Statistics............................................................................................................................................................................ 175

Received (RX).......................................................................................................................................................................... 175

UMB Cast (RX)........................................................................................................................................................................ 176

Transmitted (TX)...................................................................................................................................................................... 177

Packet Errors.................................................................................................................................................................................. 177

Received (RX).......................................................................................................................................................................... 177

Transmitted (TX)...................................................................................................................................................................... 179

Packet Size..................................................................................................................................................................................... 180

Browse Router Port........................................................................................................................................................................ 181

VLAN Status ................................................................................................................................................................................. 181

MAC Address Table ...................................................................................................................................................................... 182

Switch History Log........................................................................................................................................................................ 183

IGMP Snooping Group............................................................................................................................................................. 184

Port Access Control Information ................................................................................................................................................... 185

RADIUS Account Client.......................................................................................................................................................... 185

RADIUS Auth Client..................................................................................................................................................................... 187

Browse ARP Table ........................................................................................................................................................................ 189

Technical Specifications .................................................................................................................... 190

Appendix B ......................................................................................................................................... 192

Cables and Connectors ............................................................................................................................................................. 192

Appendix C ......................................................................................................................................... 193

Cable Lengths........................................................................................................................................................................... 193

Glossary............................................................................................................................................... 194

Warrenties/Registration .................................................................................................................... 196

Tech Support ...................................................................................................................................... 206

Intenational Offices .................................................................................................................................................................. 233

xStack DGS-3400 Series Fast Ethernet Switch

Intended Readers

The xStack DGS-3400 series Manual contains information for setup and management of the Switch. This manual is intended for network managers familiar with network management concepts and terminology.

Typographical Conventions

Convention

[ ]

Description

In a command line, square brackets indicate an optional entry. For example: [copy filename] means that optionally you can type copy followed by the name of the file.

Do not type the brackets.

Bold font

Boldface Typewriter Indicates commands and responses to prompts that must be typed exactly as

Font printed in the manual.

Initial capital letter Indicates a window name. Names of keys on the keyboard have initial capitals. For example: Click Enter.

Italics

Indicates a button, a toolbar icon, menu, or menu item. For example: Open the File menu and choose Cancel. Used for emphasis. May also indicate system messages or prompts appearing on screen. For example: You have mail. Bold font is also used to represent filenames, program names and commands. For example: use the copy command.

Menu Name > Menu

Option

Indicates a window name or a field. Also can indicate a variables or parameter that is replaced with an appropriate word or string. For example: type filename means that the actual filename should be typed instead of the word shown in italic.

Menu Name > Menu Option Indicates the menu structure. Device > Port > Port

Properties means the Port Properties menu option under the Port menu option that is located under the Device menu.

Notes, Notices, and Cautions

A NOTE indicates important information that helps make better use of the device.

A NOTICE indicates either potential damage to hardware or loss of data and tells how to avoid the problem.

A CAUTION indicates a potential for property damage, personal injury, or death. viii

xStack DGS-3400 Series Fast Ethernet Switch

Safety Instructions

Use the following safety guidelines to ensure your own personal safety and to help protect your system from potential damage. Throughout this safety section, the caution icon ( ) is used to indicate cautions and precautions that need to be reviewed and followed.

Safety Cautions

To reduce the risk of bodily injury, electrical shock, fire, and damage to the equipment, observe the following precautions.

• Observe and follow service markings.

Do not service any product except as explained in the system documentation.

Opening or removing covers that are marked with the triangular symbol with a lightning bolt may expose the user to electrical shock.

Only a trained service technician should service components inside these compartments.

If any of the following conditions occur, unplug the product from the electrical outlet and replace the part or contact your trained service provider:

Damage to the power cable, extension cable, or plug.

An object has fallen into the product.

The product has been exposed to water.

The product has been dropped or damaged.

The product does not operate correctly when the operating instructions are correctly followed.

Keep your system away from radiators and heat sources. Also, do not block cooling vents.

Do not spill food or liquids on system components, and never operate the product in a wet environment. If the system gets wet, see the appropriate section in the troubleshooting guide or contact your trained service provider.

Do not push any objects into the openings of the system. Doing so can cause fire or electric shock by shorting out interior components.

Use the product only with approved equipment.

Allow the product to cool before removing covers or touching internal components.

Operate the product only from the type of external power source indicated on the electrical ratings label. If unsure of the type of power source required, consult your service provider or local power company.

To help avoid damaging the system, be sure the voltage selection switch (if provided) on the power supply is set to match the power available at the Switch’s location:

115 volts (V)/60 hertz (Hz) in most of North and South America and some Far Eastern countries such as South

Korea and Taiwan

100 V/50 Hz in eastern Japan and 100 V/60 Hz in western Japan

230 V/50 Hz in most of Europe, the Middle East, and the Far East

Also, be sure that attached devices are electrically rated to operate with the power available in your location.

Use only approved power cable(s). If you have not been provided with a power cable for your system or for any ACpowered option intended for your system, purchase a power cable that is approved for use in your country. The power cable must be rated for the product and for the voltage and current marked on the product's electrical ratings label.

The voltage and current rating of the cable should be greater than the ratings marked on the product. ix

xStack DGS-3400 Series Fast Ethernet Switch

To help prevent electric shock, plug the system and peripheral power cables into properly grounded electrical outlets.

These cables are equipped with three-prong plugs to help ensure proper grounding. Do not use adapter plugs or remove the grounding prong from a cable. If using an extension cable is necessary, use a 3-wire cable with properly grounded plugs.

Observe extension cable and power strip ratings. Make sure that the total ampere rating of all products plugged into the extension cable or power strip does not exceed 80 percent of the ampere ratings limit for the extension cable or power strip.

To help protect the system from sudden, transient increases and decreases in electrical power, use a surge suppressor, line conditioner, or uninterruptible power supply (UPS).

Position system cables and power cables carefully; route cables so that they cannot be stepped on or tripped over. Be sure that nothing rests on any cables.

Do not modify power cables or plugs. Consult a licensed electrician or your power company for site modifications.

Always follow your local/national wiring rules.

When connecting or disconnecting power to hot-pluggable power supplies, if offered with your system, observe the following guidelines:

Install the power supply before connecting the power cable to the power supply.

Unplug the power cable before removing the power supply.

If the system has multiple sources of power, disconnect power from the system by unplugging all power cables from the power supplies.

Move products with care; ensure that all casters and/or stabilizers are firmly connected to the system. Avoid sudden stops and uneven surfaces.

General Precautions for Rack-Mountable Products

Observe the following precautions for rack stability and safety. Also, refer to the rack installation documentation accompanying the system and the rack for specific caution statements and procedures.

• Systems are considered to be components in a rack. Thus, "component" refers to any system as well as to various peripherals or supporting hardware.

CAUTION: Installing systems in a rack without the front and side stabilizers installed could cause the rack to tip over, potentially resulting in bodily injury under certain circumstances.

Therefore, always install the stabilizers before installing components in the rack. After installing system/components in a rack, never pull more than one component out of the rack on its slide assemblies at one time. The weight of more than one extended component could cause the rack to tip over and may result in serious injury.

Before working on the rack, make sure that the stabilizers are secured to the rack, extended to the floor, and that the full weight of the rack rests on the floor. Install front and side stabilizers on a single rack or front stabilizers for joined multiple racks before working on the rack.

Always load the rack from the bottom up, and load the heaviest item in the rack first.

Make sure that the rack is level and stable before extending a component from the rack.

Use caution when pressing the component rail release latches and sliding a component into or out of a rack; the slide rails can pinch your fingers.

After a component is inserted into the rack, carefully extend the rail into a locking position, and then slide the component into the rack. x

xStack DGS-3400 Series Fast Ethernet Switch

Do not overload the AC supply branch circuit that provides power to the rack. The total rack load should not exceed

80 percent of the branch circuit rating.

Ensure that proper airflow is provided to components in the rack.

Do not step on or stand on any component when servicing other components in a rack.

NOTE: A qualified electrician must perform all connections to DC power and to safety grounds. All electrical wiring must comply with applicable local or national codes and practices.

CAUTION: Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if uncertain that suitable grounding is available.

CAUTION: The system chassis must be positively grounded to the rack cabinet frame.

Do not attempt to connect power to the system until grounding cables are connected.

Completed power and safety ground wiring must be inspected by a qualified electrical inspector. An energy hazard will exist if the safety ground cable is omitted or disconnected.

Protecting Against Electrostatic Discharge

Static electricity can harm delicate components inside the system. To prevent static damage, discharge static electricity from your body before touching any of the electronic components, such as the microprocessor. This can be done by periodically touching an unpainted metal surface on the chassis.

The following steps can also be taken prevent damage from electrostatic discharge (ESD):

1. When unpacking a static-sensitive component from its shipping carton, do not remove the component from the antistatic packing material until ready to install the component in the system. Just before unwrapping the antistatic packaging, be sure to discharge static electricity from your body.

2. When transporting a sensitive component, first place it in an antistatic container or packaging.

3. Handle all sensitive components in a static-safe area. If possible, use antistatic floor pads, workbench pads and an antistatic grounding strap. xi

xStack DGS-3400 Series Fast Ethernet Switch

Section 1

Introduction

Ethernet Technology

Switch Description

Features

Ports

Front-Panel Components

Side Panel Description

Rear Panel Description

Gigabit Combo Ports

Ethernet Technology

Fast Ethernet Technology

The DGS-3400 Gigabit Ethernet switches are members of the D-Link xStack family. Ranging from 10/100Mbps edge switches to core gigabit switches, the xStack switch family has been future-proof designed to deliver a system with fault tolerance, flexibility, port density, robust security and maximum throughput with a user-friendly management interface for the networking professional.

This manual describes the installation, maintenance and configurations concerning members of the xStack DGS-3400

Switch Series. These switches include: the DGS-3426, DGS-3427 and the DGS-3450. The DGS-3400 Series switches are similar in configurations and basic hardware and consequentially, most of the information in this manual will be universal to the whole xStack DGS-3400 Series. Corresponding screen pictures of the web manager may be taken from any one of these switches but the configuration will be identical, except for varying port counts.

Switch Description

D-Link's next-generation xStack DGS-3400 series switches are high port-density stackable switches that combine the ultimate performance with fault tolerance, security, management functions with flexibility and ease-of-use. All these features, typically found in the more expensive chassis-based solutions, are available from the xStack DGS-3400 switch series at the price of a stackable switch!

All xStack DGS-3400 Series switches have some combination of 1000BASE-T ports, SFP ports and 10-Gigabit ports that may be used in uplinking various network devices to the Switch, including PCs, hubs and other switches to provide a gigabit Ethernet uplink in full-duplex mode. The SFP (Small Form Factor Portable) combo ports are used with fiber-optical transceiver cabling in order to uplink various other networking devices for a gigabit link that may span great distances.

These SFP ports support full-duplex transmissions, have auto-negotiation and can be used with DEM-310GT (1000BASE-

LX), DEM-311GT (1000BASE-SX), DEM-314GT (1000BASE-LH) and DEM-315GT (1000BASE-ZX) transceivers. The rear panel of the DGS-3400 Series Switches include spaces for optional single-port module inserts for single port 10GE

XFP or 10GBASE-CX4 modules used for backbone uplink or STACKING connection to another xStack DGS-3400 Series

Switch.

1

xStack DGS-3400 Series Fast Ethernet Switch

Features

The list of features below highlights the significant freatures of the xStack DGS-3400 Series.

• IEEE 802.3z compliant

IEEE 802.3x Flow Control in full-duplex compliant

IEEE 802.3u compliant

IEEE 802.3ab compliant

IEEE 802.3ae compliant (for optional XFP module)

IEEE 802.1p Priority Queues

IEEE 802.3ad Link Aggregation Control Protocol support.

IEEE 802.1x Port-based and MAC-based Access Control

IEEE 802.1Q VLAN

IEEE 802.1D Spanning Tree, IEEE 802.1W Rapid Spanning Tree and IEEE 802.1s Multiple Spanning Tree support

STACKING support in either Ring or Star topology

Access Control List (ACL) support

IP Multinetting support

Protocol VLAN support

Single IP Management support

Access Authentication Control utilizing TACACS, XTACACS, TACACS+ and RADIUS protocols

Dual Image Firmware

Simple Network Time Protocol support

MAC Notification support

System and Port Utilization support

System Log Support

High performance switching engine performs forwarding and filtering at full wire speed up to 128Gbps.

• Full- and half-duplex for all gigabit ports. Full duplex allows the switch port to simultaneously transmit and receive data. It only works with connections to full-duplex-capable end stations and switches. Connections to a hub must take place at half-duplex.

Support broadcast storm filtering

Non-blocking store and forward switching scheme capability to support rate adaptation and protocol conversion

Supports by-port Egress/Ingress rate control

Efficient self-learning and address recognition mechanism enables forwarding rate at wire speed

Support port-based enable and disable

Address table: Supports up to 8K MAC addresses per device

Supports a packet buffer of up to 3 Mbits

Supports Port-based VLAN Groups

Port Trunking with flexible load distribution and fail-over function

IGMP Snooping support

• IGMP version 3

2

xStack DGS-3400 Series Fast Ethernet Switch

SNMP support

Secure Sockets Layer (SSL) and Secure Shell (SSH) support

System Severity control

Port Mirroring support

MIB support for:

RFC1213 MIB II

RFC1493 Bridge

RFC1757 RMON

RFC1643 Ether-like MIB

RFC2233 Interface MIB

IF MIB

Private MIB

RFC2674 for 802.1p

IEEE 802.1x MIB

RS-232 DCE console port for Switch management

Provides parallel LED display for port status such as link/act, speed, etc.

Ports

The DGS-3400 Series Switches have port options as listed by device.

DGS-3426

Twenty-four

10/100/1000BASE-T Gigabit ports

Four Combo SFP Ports

Two slots open for single port

10GE XFP or 10GBASE-CX4 modules

One RS-232 DB-9 console port

DGS-3427

Gigabit ports

Four Combo SFP Ports

Three slots open for single port

10GE XFP or 10GBASE-CX4 modules

One RS-232 DB-9 console port

DGS-3450

• Forty-eight 10/100/1000BASE-

T Gigabit ports

Four Combo SFP Ports

Two slots open for single port

10GE XFP or 10GBASE-CX4 modules

• One RS-232 DB-9 console port

NOTE: For customers interested in D-View, D-Link Corporation's proprietary SNMP management software, go to the D-Link Website and download the software and manual.

3

xStack DGS-3400 Series Fast Ethernet Switch

Front-Panel Components

The front panel of the Switch consists of LED indicators for Power, Master, Console, RPS, and for Link/Act for each port on the Switch including 10GE Ports for optional modules and SFP port LEDs. The front panel includes a seven-segment

LED indicating the Stack ID number*. A seperate table below describes LED indicators in more detail.

* Note that Stacking in the DGS-3400 Series is not yet supported in this firmware release.

DGS-3426

DGS-3427

Figure 2- 1. Front Panel View of the DGS-3426 as shipped

DGS-3450

Figure 2- 2. Front Panel View of the DGS-3427 as shipped

Figure 2- 3. Front Panel View of the DGS-3450 as shipped

4

xStack DGS-3400 Series Fast Ethernet Switch

LED Indicators

The Switch supports LED indicators for Power, Console, RPS and Port LEDs including 10GE port LEDs for optional module inserts..

Figure 2- 4. LED Indicators on DGS-3450

Figure 2- 5. LED Indicators on DGS-3427

Figure 2- 6. LED Indicators on DGS-3426

5

xStack DGS-3400 Series Fast Ethernet Switch

LED Description

Power

Console

RPS

Port LEDs

10GE Ports

Combo SFP Ports

This LED will light green after powering the Switch on to indicate the ready state of the device. The indicator is dark when the Switch is no longer receiving power

(i.e powered off).

This LED will blink green during the Power-On Self Test (POST). When the

POST is finished, the LED goes dark. The indicator will light steady green when an active console link is in session via RS-232 console port.

This LED will light when the internal power has failed and the RPS has taken over the power supply to the Switch. Otherwise, it will remain dark.

One row of LEDs for each port is located above the ports on the front panel. The indicator above the left side of a port corresponds to the port below the indicator in the upper row of ports. The indicator above the right side of a port corresponds to the port below the indicator in the lower row of ports. A steady green light denotes a valid 1000Mbps link on the port while a blinking green light indicates activity on the port (at 1000Mbps). A steady orange light denotes a valid 10 or

100Mbps link on the port while a blinking orange light indicates activity on the port

(at 100Mbps). These LEDs will remain dark if there is no link/activity on the port.

A steady green light denotes a valid link on the port while a blinking green light indicates activity on the port. These LEDs will remain dark if there is no link/activity on the port.

LED indicators for the Combo ports are located above the ports and numbered

1 – 4 for Comb 1, Combo 2, etc. ports. A steady green light denotes a valid link on the port while a blinking green light indicates activity on the port. These LEDs will remain dark if there is no link/activity on the port.

Stack ID*

These two seven segment LEDs display the current switch stack order of the

Switch while in use.

* Note that Stacking in the DGS-3400 Series is not yet supported in this firmware release.

6

xStack DGS-3400 Series Fast Ethernet Switch

Rear Panel Description

DGS-3426

The rear panel of the DGS-3426 contains an AC power connector, a redundant power supply connector and two empty slots for optional module inserts.

Figure 2- 7. Rear panel view of DGS-3426

DGS-3427

The rear panel of the DGS-3427 contains an AC power connector, a redundant power supply connector and three empty slots for optional module inserts.

Figure 2- 8. Rear panel view of DGS-3427

DGS-3450

The rear panel of the DGS-3450 contains an AC power connector, two empty slots for optional module inserts, a redundant power supply connector, a RS-232 DCE console port for Switch management and a system fan vent.

Figure 2- 9. Rear panel view of DGS-3450

The AC power connector is a standard three-pronged connector that supports the power cord. Plug-in the female connector of the provided power cord into this socket, and the male side of the cord into a power outlet. The Switch automatically adjusts its power setting to any supply voltage in the range from 100 ~ 240 VAC at 50 ~ 60 Hz.

The rear panel also includes an outlet for an optional external power supply. When a power failure occurs, the optional external RPS will immediately and automatically assume the power supply for the Switch.

7

xStack DGS-3400 Series Fast Ethernet Switch

Side Panel Description

DGS-3426 & DGS-3450

The system fans and heat vents located on each side dissipate heat. Do not block these openings. Leave at least 6 inches of space at the rear and sides of the Switch for proper ventilation. Be reminded that without proper heat dissipation and air circulation, system components might overheat, which could lead to system failure and severely damage components.

Figure 2- 10. Side Panels (DGS-3450)

Figure 2- 11. Side Panels (DGS-3426 and DGS-3427)

8

xStack DGS-3400 Series Fast Ethernet Switch

Section 2

Installation

Package Contents

Installation Guidelines

Installing the Switch without the Rack

Rack Installation

Power On

The Optional Module

Redundant Power System

Package Contents

Open the shipping carton of the Switch and carefully unpack its contents. The carton should contain the following items:

1. One xStack Stackable Switch

2. One AC power cord

3. Mounting kit (two brackets and screws)

4. Four rubber feet with adhesive backing

5. RS-232 console cable

6. One CD Kit for User’s Guide/CLI/D-View module

7. One CD Kit for D-View 5.1 Standard version(for Europe only)

8. Registration card & China Warranty Card (for China only)

If any item is missing or damaged, please contact your local D-Link Reseller for replacement.

Installation Guidelines

Please follow these guidelines for setting up the Switch:

• Install the Switch on a sturdy, level surface that can support at least 6.6 lb. (3 kg) of weight. Do not place heavy objects on the Switch.

• The power outlet should be within 1.82 meters (6 feet) of the Switch.

Visually inspect the power cord and see that it is fully secured to the AC power port.

Make sure that there is proper heat dissipation from and adequate ventilation around the Switch. Leave at least 10 cm

(4 inches) of space at the front and rear of the Switch for ventilation.

Install the Switch in a fairly cool and dry place for the acceptable temperature and humidity operating ranges.

Install the Switch in a site free from strong electromagnetic field generators (such as motors), vibration, dust, and direct exposure to sunlight.

• When installing the Switch on a level surface, attach the rubber feet to the bottom of the device. The rubber feet cushion the Switch, protect the casing from scratches and prevent it from scratching other surfaces.

9

xStack DGS-3400 Series Fast Ethernet Switch

Installing the Switch without the Rack

First, attach the rubber feet included with the Switch if installing on a desktop or shelf. Attach these cushioning feet on the bottom at each corner of the device. Allow enough ventilation space between the Switch and any other objects in the vicinity.

Figure 2- 12. Prepare Switch for installation on a desktop or shelf

Installing the Switch in a Rack

The Switch can be mounted in a standard 19" rack. Use the following diagrams as a guide.

Figure 2- 13. Fasten mounting brackets to Switch

Fasten the mounting brackets to the Switch using the screws provided. With the brackets attached securely, the Switch can be mounted in a standard rack as shown below.

10

xStack DGS-3400 Series Fast Ethernet Switch

Mounting the Switch in a Standard 19" Rack

Figure 2- 14. Installing Switch in a rack

Power On

1. Plug one end of the AC power cord into the power connector of the Switch and the other end into the local power source outlet.

2. After powering on the Switch, the LED indicators will momentarily blink. This blinking of the LED indicators represents a reset of the system.

Power Failure

As a precaution, in the event of a power failure, unplug the Switch. When power is resumed, plug the Switch back in.

11

xStack DGS-3400 Series Fast Ethernet Switch

Installing the SFP ports

The xStack DGS-3400 series switches are equipped with SFP (Small Form Factor Portable) ports, which are to be used with fiber-optical transceiver cabling in order to uplink various other networking devices for a gigabit link that may span great distances. These SFP ports support full-duplex transmissions, have auto-negotiation and can be used with DEM-

310GT (1000BASE-LX), DEM-311GT (1000BASE-SX), DEM-314GT (1000BASE-LH) and DEM-315GT (1000BASE-

ZX) transceivers. See the figure below for installing the SFP ports in the Switch.

Figure 2- 15. Inserting the fiber-optic transceivers into the DGS-3426

12

xStack DGS-3400 Series Fast Ethernet Switch

The Optional Module

The rear panel of the DGS-3426, DGS-3427 and DGS-3450 include open slots that may be equipped with the DEM-410X

1-port 10GE XFP uplink module, or a DEM-410CX 1-port 10GBASE-CX4 uplink module, both sold separately.

Adding the DEM-410X optional module will allow the administrator to transmit data at a rate of ten gigabits a second. The module port(s) are compliant with standard IEEE 802.3ae, support full-duplex transmissions only and must be used with

XFP MSA compliant transceivers.

The DEM-410CX uses copper wire medium, not optic fiber and therefore has a transmit length limit up to 1 meters.

Compliant with the IEEE802.3ak standard, this module uses a 4-laned copper connector for data transfer in full-duplex mode.

To install these modules in the DGS-3400 Series Switch, follow the simple steps listed below.

CAUTION: Before adding the optional module, make sure to disconnect all power sources connected to the Switch. Failure to do so may result in an electrical shock, which may cause damage, not only to the individual but to the Switch as well.

At the back of the Switch to the left is the slot for the optional module. This slot must be covered with the faceplate if the slot is not being used. If a module will be installed in an available slot, the faceplate is easily removed by loosening the screws and pulling off the plate.

The front panels of the available modules are shown here:

Figure 2- 16. Front Panel of the DEM-410X

Figure 2- 17. Front Panel of the DEM-410CX

13

xStack DGS-3400 Series Fast Ethernet Switch

Install the Module

Unplug the Switch before removing the faceplate covering the empty slot. To install the module, slide it in to the available slot at the rear of the Switch until it reaches the back, as shown in the following figure. Gently, but firmly push in on the module to secure it to the Switch. The module should fit snugly into the corresponding receptors.

Figure 2- 18. Inserting the optional module into the Switch (DGS-3450)

Now tighten the two screws at adjacent ends of the module into the available screw holes on the Switch. The upgraded

Switch is now ready for use.

Figure 2- 19. DGS-3450 with optional DEM-410X module installed

14

xStack DGS-3400 Series Fast Ethernet Switch

External Redundant Power System

The Switch supports an external redundant power system. The diagrams below illustrate a proper RPS power connection to the Switch. Please consult the documentation for information on power cabling and connectors and setup procedure.

Figure 2- 20. The DGS-3450 with the DPS-500 chassis RPS

15

xStack DGS-3400 Series Fast Ethernet Switch

Figure 2- 21. The DGS-3450 with the DPS-500 Redundant External Power Supply

NOTE: See the DPS-500 documentation for more information.

CAUTION: Do not use the Switch with any redundant power system other than the DPS-500.

16

xStack DGS-3400 Series Fast Ethernet Switch

Section 3

Connecting the Switch

Switch To End Node

Switch to Switch

Connecting To Network Backbone or Server

NOTE: All high-performance N-Way Ethernet ports can support both MDI-II and MDI-X connections.

Switch to End Node

End nodes include PCs outfitted with a 10, 100 or 1000 Mbps RJ-45 Ethernet Network Interface Card (NIC) and routers.

An end node connects to the Switch via a twisted-pair UTP/STP cable. Connect the end node to any of the 1000BASE-T ports of the Switch.

The Link/Act LEDs for each UTP port will light green or amber when the link is valid. A blinking LED indicates packet activity on that port.

Switch to Switch

There is a great deal of flexibility on how connections are made using the appropriate cabling.

• Connect a 10BASE-T hub or switch to the Switch via a twisted-pair Category 3, 4 or 5 UTP/STP cable.

Connect a 100BASE-TX hub or switch to the Switch via a twisted-pair Category 5 UTP/STP cable.

Connect 1000BASE-T switch to the Switch via a twisted pair Category 5e UTP/STP cable.

• Connect switch supporting a fiber-optic uplink to the Switch’s SFP ports via fiber-optic cabling. See cabling guidelines in Appendix B for more information.

Figure 3- 1. Connect the Switch to a port on a switch with straight or crossover cable

Connecting To Network Backbone or Server

The combo SFP ports and the 1000BASE-T ports are ideal for uplinking to a network backbone, server or server farm. The copper ports operate at a speed of 1000, 100 or 10Mbps in full or half duplex mode. The fiber-optic ports can operate at

1000Mbps in full duplex mode only.

Connections to the Gigabit Ethernet ports are made using a fiber-optic cable or Category 5e copper cable, depending on the type of port. A valid connection is indicated when the Link LED is lit.

17

xStack DGS-3400 Series Fast Ethernet Switch

Section 4

Introduction to Switch Management

Management Options

Connecting the Console Port (RS-232 DCE)

First Time Connecting to the Switch

Password Protection

SNMP Settings

IP Address Assignment

Connecting Devices to the Switch

Management Options

This system may be managed out-of-band through the console port on the front panel or in-band using Telnet. The user may also choose the web-based management, accessible through a web browser.

1. Web-based Management Interface

After successfully installing the Switch, the user can configure the Switch, monitor the LED panel, and display statistics graphically using a web browser, such as Netscape Navigator (version 6.2 and higher) or Microsoft®

Internet Explorer (version 5.0).

The Switch can be managed with an SNMP-compatible console program. The Switch supports SNMP version 1.0, version 2.0 and version 3.0. The SNMP agent decodes the incoming SNMP messages and responds to requests with MIB objects stored in the database. The SNMP agent updates the MIB objects to generate statistics and counters.

3. Command Line Console Interface through the Serial Port

The user can also connect a computer or terminal to the serial console port to access the Switch. The commandline-driven interface provides complete access to all Switch management features.

18

xStack DGS-3400 Series Fast Ethernet Switch

Connecting the Console Port (RS-232 DCE)

The Switch provides an RS-232 serial port that enables a connection to a computer or terminal for monitoring and configuring the Switch. This port is a female DB-9 connector, implemented as a data terminal equipment (DTE) connection.

To use the console port, the following equipment is needed:

• A terminal or a computer with both a serial port and the ability to emulate a terminal.

• A null modem or crossover RS-232 cable with a female DB-9 connector for the console port on the Switch.

To connect a terminal to the console port:

Connect the female connector of the RS-232 cable directly to the console port on the Switch, and tighten the captive retaining screws.

Connect the other end of the cable to a terminal or to the serial connector of a computer running terminal emulation software. Set the terminal emulation software as follows:

Select the appropriate serial port (COM port 1 or COM port 2).

Set the data rate to 115200 baud.

Set the data format to 8 data bits, 1 stop bit, and no parity.

Set flow control to none.

Under Properties, select VT100 for Emulation mode.

Select Terminal keys for Function, Arrow and Ctrl keys. Make sure to use Terminal keys (not Windows keys) are selected.

NOTE: When using HyperTerminal with the Microsoft® Windows® 2000 operating system, ensure that Windows 2000 Service Pack 2 or later is installed. Windows 2000 Service Pack 2 allows use of arrow keys in HyperTerminal's VT100 emulation. See www.microsoft.com for information on

Windows 2000 service packs.

• After you have correctly set up the terminal, plug the power cable into the power receptacle on the back of the Switch.

The boot sequence appears in the terminal.

• After the boot sequence completes, the console login screen displays.

• If the user has not logged into the command line interface (CLI) program, press the Enter key at the User name and password prompts. There is no default user name and password for the Switch. The administrator must first create user names and passwords. If user accounts have been previously set up, log in and continue to configure the Switch.

• Enter the commands to complete desired tasks. Many commands require administrator-level access privileges. Read the next section for more information on setting up user accounts. See the xStack DGS-3400 series CLI Manual on the documentation CD for a list of all commands and additional information on using the CLI.

• To end a management session, use the logout command or close the emulator program.

If problems occur in making this connection on a PC, make sure the emulation is set to VT-100. The emulation settings can be configured by clicking on the File menu in the HyperTerminal window by clicking on Properties in the drop-down menu, and then clicking the Settings tab. This is where you will find the Emulation options. If you still do not see anything, try rebooting the Switch by disconnecting its power supply.

19

xStack DGS-3400 Series Fast Ethernet Switch

Once connected to the console, the screen below will appear on the console screen. This is where the user will enter commands to perform all the available management functions. The Switch will prompt the user to enter a user name and a password. Upon the initial connection, there is no user name or password and therefore just press enter twice to access the command line interface.

Figure 4- 1. Boot up display in console screen (DGS-3427)

Managing the Switch for the First Time

The Switch supports user-based security that can allow prevention of unauthorized users from accessing the Switch or changing its settings. This section tells how to log onto the Switch via out-if-band console connection.

NOTE: The passwords used to access the Switch are case-sensitive; for example,

"S" is not the same as "s."

Upon initial connection to the Switch, the login screen appears (see example below).

NOTE: Press Ctrl+R to refresh the screen. This command can be used at any time to force the console program in the Switch to refresh the console screen.

20

xStack DGS-3400 Series Fast Ethernet Switch

Figure 4- 2. Initial screen, first time connecting to the Switch

Press Enter in both the Username and Password fields. Then access will be given to enter commands after the command prompt DGS-3426:4#, DGS-3427:4# or DGS-3450:4# as shown below:

There is no initial username or password. Leave the Username and Password fields blank.

Figure 4- 3. Command Prompt

NOTE: The first user automatically gets Administrator level privileges. ItAt least one Admin-level user account must be created for the Switch.

21

xStack DGS-3400 Series Fast Ethernet Switch

Password Protection

The xStack DGS-3400 Series switches do not have a default user name and password. One of the first tasks when settings up the Switch is to create user accounts. Logging in using a predefined administrator-level user name will give the user privileged access to the Switch's management software.

After the initial login, define new passwords for both default user names to prevent unauthorized access to the Switch, and record the passwords for future reference.

To create an administrator-level account for the Switch, do the following:

1. At the CLI login prompt, enter create account admin followed by the <user name> and press the Enter key.

2. The Switch will then prompt the user to provide a password. Type the <password> used for the administrator account being created and press the Enter key.

3. Once entered, the Switch will again ask the user to enter the same password again to verify it. Type the same password and press the Enter key.

4. A “Success” response by the Switch will verify the creation of the new administrator.

NOTE: Passwords are case sensitive. User names and passwords can be up to 15 characters in length.

The sample below illustrates a successful creation of a new administrator-level account with the user name "newmanager".

DGS-34xx:4#create account admin newmanager

Command: create account admin newmanager

Enter a case-sensitive new password:********

Enter the new password again for confirmation:********

Success.

DGS-34xx:4#

NOTICE: CLI configuration commands only modify the running configuration file and are not saved when the Switch is rebooted. To save all configuration changes in non-volatile memory, use the save command to copy the running configuration file to the startup configuration.

22

xStack DGS-3400 Series Fast Ethernet Switch

SNMP Settings

Simple Network Management Protocol (SNMP) is an OSI Layer 7 (Application Layer) designed specifically for managing and monitoring network devices. SNMP enables network management stations to read and modify the settings of gateways, routers, switches and other network devices. Use SNMP to configure system features for proper operation, monitor performance and detect potential problems in the Switch, switch group or network.

Managed devices that support SNMP include software (referred to as an agent), which runs locally on the device. A defined set of variables (managed objects) is maintained by the SNMP agent and used to manage the device. These objects are defined in a Management Information Base (MIB), which provides a standard presentation of the information controlled by the on-board SNMP agent. SNMP defines both the format of the MIB specifications and the protocol used to access this information over the network.

The xStack DGS-3400 series switches support SNMP versions 1, 2c, and 3. The administrator may specify which version of SNMP to use to monitor and control the Switch. The three versions of SNMP vary in the level of security provided between the management station and the network device.

In SNMP v.1 and v.2, user authentication is accomplished using 'community strings', which function like passwords. The remote user SNMP application and the Switch SNMP must use the same community string. SNMP packets from any station that has not been authenticated are ignored (dropped).

The default community strings for the Switch used for SNMP v.1 and v.2 management access are:

• public - Allows authorized management stations to retrieve MIB objects.

• private - Allows authorized management stations to retrieve and modify MIB objects.

SNMP v.3 uses a more sophisticated authentication process that is separated into two parts. The first part is to maintain a list of users and their attributes that are allowed to act as SNMP managers. The second part describes what each user on that list can do as an SNMP manager.

The Switch allows groups of users to be listed and configured with a shared set of privileges. The SNMP version may also be set for a listed group of SNMP managers. Thus, a group of SNMP managers can be created to view read-only information or receive traps using SNMP v.1 while assigning a higher level of security to another group, granting read/write privileges using SNMP v.3.

Using SNMP v.3 individual users or groups of SNMP managers can be allowed to perform or be restricted from performing specific SNMP management functions. The functions allowed or restricted are defined using the Object

Identifier (OID) associated with a specific MIB. An additional layer of security is available for SNMP v.3 in that SNMP messages may be encrypted. To read more about how to configure SNMP v.3 settings for the Switch read the section entitled Management.

Traps

Traps are messages that alert network personnel of events that occur on the Switch. The events can be as serious as a reboot (someone accidentally turned OFF the Switch), or less serious like a port status change. The Switch generates traps and sends them to the trap recipient (or network manager). Typical traps include trap messages for Authentication Failure,

Topology Change and Broadcast\Multicast Storm.

MIBs

The Switch in the Management Information Base (MIB) stores management and counter information. The Switch uses the standard MIB-II Management Information Base module. Consequently, values for MIB objects can be retrieved from any

SNMP-based network management software. In addition to the standard MIB-II, the Switch also supports its own proprietary enterprise MIB as an extended Management Information Base. The proprietary MIB may also be retrieved by specifying the MIB Object Identifier. MIB values can be either read-only or read-write.

23

xStack DGS-3400 Series Fast Ethernet Switch

IP Address Assignment

An IP Address must be assigned to each switch, which is used for communication with an SNMP network manager or other TCP/IP application (for example BOOTP, TFTP). The Switch's default IP address is 0.0.00 (i.e. no default IP address). The user may change the default Switch IP address to meet the specification of your networking address scheme.

The Switch is also assigned a unique MAC address by the factory. This MAC address cannot be changed, and can be found by entering the command "show switch" into the command line interface, as shown below.

Figure 4- 4. “show switch” command

The Switch's MAC address also appears in Switch Information menu of the web-based management interface.

The IP address for the Switch must be set beforeusing the Web-based manager. The Switch IP address can be automatically set using BOOTP or DHCP protocols, in which case the actual address assigned to the Switch must be known.

The IP address may be set using the Command Line Interface (CLI) over the console serial port as follows:

Starting at the command line prompt, enter the command:

config ipif System ipaddress xxx.xxx.xxx.xxx/yyy.yyy.yyy.yyy

Where the x's represent the IP address to be assigned to the IP interface named System and the y's represent the corresponding subnet mask.

Alternatively, the user can enter config ipif System ipaddress xxx.xxx.xxx.xxx/z. Where the x's represent the IP address to be assigned to the IP interface named System and the z represents the corresponding number of subnets in CIDR notation.

The IP interface named System on the Switch can be assigned an IP address and subnet mask, which can then be used to connect a management station to the Switch's Telnet or Web-based management agent.

24

xStack DGS-3400 Series Fast Ethernet Switch

Figure 4- 5. Assigning the Switch an IP Address

In the above example, the Switch was assigned an IP address of 10.34.27.100 with a subnet mask of 255.0.0.0. The system message Success indicates that the command was executed successfully. The Switch can now be configured and managed via Telnet and the CLI or via the Web-based management.

25

xStack DGS-3400 Series Fast Ethernet Switch

Section 5

Web-based Switch Configuration

Introduction

Logging on to the Web Manager

Web-Based User Interface

Basic Setup

Reboot

Basic Switch Setup

Network Management

Switch Utilities

Network Monitoring

IGMP Snooping Status

Introduction

All software functions of the xStack DGS-3400 switch series can be managed, configured and monitored via the embedded web-based (HTML) interface. Manage the Switch from remote stations anywhere on the network through a standard browser. The browser acts as a universal access tool and can communicate directly with the Switch using the HTTP protocol.

The Web-based management module and the Console program (and Telnet) are different ways to access the same internal switching software and configure it. Thus, all settings encountered in web-based management are the same as those found in the console program.

26

xStack DGS-3400 Series Fast Ethernet Switch

Logging in to the Web Manager

To begin managing the Switch, simply run the browser installed on your computer and point it to the IP address you have defined for the device. The URL in the address bar should read something like: http://123.123.123.123, where the numbers

123 represent the IP address of the Switch.

NOTE: There is no factory default IP address.

In the page that opens, click on the Login hyperlink:

Figure 5- 1. Click on Login hyperlink

This opens the management module's user authentication window, as seen below.

Figure 5- 2. Enter Network Password window

Leave both the User Name field and the Password field blank and click OK. This will open the Web-based user interface.

The Switch management features available in the web-based manager are explained below.

27

xStack DGS-3400 Series Fast Ethernet Switch

Web-based User Interface

The user interface provides access to various Switch configuration and management screens, allows the user to view performance statistics, and permits graphical monitoring of the system status.

Areas of the User Interface

The figure below shows the user interface. Three distinct areas divide the user interface, as described in the table.

Area 2

Area 1

Area 3

Figure 5- 3. Main Web-Manager Screen

Area Function

Area 1

Area 2

Area 3

Select the menu or window to display. Open folders and click the hyperlinked menu buttons and subfolders contained within them to display menus. Click the D-Link logo to go to the D-Link website.

Presents a graphical near real-time image of the front panel of the Switch. This area displays the Switch's ports and expansion modules, showing port activity, duplex mode, or flow control, depending on the specified mode.

Some management functions, including port configuration are accessable here.

Presents switch information based on user selection and the entry of configuration data.

28

xStack DGS-3400 Series Fast Ethernet Switch

Web Pages

When connecting to the management mode of the Switch with a web browser, a login screen is displayed. Enter a user name and password to access the Switch's management mode.

Below is a list of the main folders available in the web interface:

Adminstration – Contains the following menu pages and sub-directories: IP Address, Port Configuration, User

Accounts, Port Mirroring, System Log Settings, System Severity Settings, SNTP Settings, MAC Notification

Settings, TFTP Services, Multiple Image Services, Ping Test, Safeguard Engine, Static ARP Settings, Routing

Table, DHCP Auto Configuration, SNMP Manager, IP-MAC Binding and Single IP Management.

L2 Features – Contains the following menu pages and sub-directories: VLAN, Trunking, IGMP Snooping,

Spanning Tree and Forwarding & Filtering.

QoS – Contains the following menu pages and sub-directories: Bandwidth Control, QoS Output Scheduling,

802.1p Default Priority and 802.1p Uer Priority.

ACL – Contains the following menu pages and sub-directories: Access Profile Table and CPU Interface

Filtering.

Security – Contains the following menu pages and sub-directories: Traffic Control, Port Security, Port Lock

Entries, 802.1x, Trusted Host, Access Authentication Control, Traffic Segmentation, SSL and SSH.

Monitoring – Contains the following menu pages and sub-directories: Device Status, Module Information, CPU

Utilization, Port Utilization, Packets, Errors, Packet Size, Browse Router Port, VLAN Status, Port Access

Control, MAC Address Table, IGMP Snooping Group, Switch Log, Browse ARP Table, Browse IPv6 ARP Table and Session Table.

Save Services – Contains the following menu pages and sub-directories: Save Changes, Configure

Information and Config Current Setting.

Reset, Reboot System and Logout menu links are displayed in the main directory.

NOTE: Be sure to configure the user name and password in the User

Accounts menu before connecting the Switch to the greater network.

29

xStack DGS-3400 Series Fast Ethernet Switch

Section 6

Configuring the Switch

Device Informatin

IP Address

Port Configuration

Port Description

User Accounts

Port Mirroring

System Log Host / System Severity Settings

SNTP / Time Zone Settings

MAC Notification TFTP / Multiple Image Services

Safeguard Engine

Static ARP

DHCP Auto Configuration

SNMP Settings

Single IP Management Settings

Device Information

The Device Information window contains the main settings for all major functions for the Switch. It appears automatically when you log on to the Switch. To return to the Device Information window after viewing other windows, click the DGS-

3400 Web Management Tool folder. The Device Information window shows the Switch’s MAC Address (assigned by the factory and unchangeable), the Boot PROM, Firmware Version, and Hardware Version. This information is helpful to keep track of PROM and firmware updates and to obtain the Switch's MAC address for entry into another network device's address table, if necessary. The user may also enter a System Name, System Location and System Contact to aid in defining the Switch, to the user's preference. In addition, this screen displays the status of functions on the Switch to quickly assess their current global status. Some Functions are hyper-linked for easy access from the Device Information window.

Many miscellaneous functions are enabled and disabled in the Device Information menu.

30

xStack DGS-3400 Series Fast Ethernet Switch

Figure 6- 1. Device Information and general settings

31

xStack DGS-3400 Series Fast Ethernet Switch

Device Information menu configurable parameters include those described in the table below.

Parameter Description

Serial Port Auto

Logout Time

Serial Baud Rate This field specifies the baud rate for the serial port on the Switch. This fields menu is set at

115200 and cannot be changed.

MAC Address

Aging Time

This field specifies the length of time a learned MAC Address will remain in the forwarding table without being accessed (that is, how long a learned MAC Address is allowed to remain idle). To change this, type in a different value representing the MAC address age-out time in seconds.

The MAC Address Aging Time can be set to any value between 10 and 1,000,000 seconds.

The default setting is 300 seconds.

IGMP Snooping

Select the logout time used for the console interface. This automatically logs the user out after an idle period of time, as defined. Choose from the following options: 2 Minutes, 5 Minutes, 10

Minutes, 15 Minutes or Never. The default setting is 10 minutes.

Multicast Router

Only

To enable system-wide IGMP Snooping capability select Enabled. IGMP snooping is Disabled by default. Enabling IGMP snooping allows you to specify use of a multicast router only (see below). To configure IGMP Snooping for individual VLANs, use the IGMP Snooping window under the IGMP folder.

This field specifies that the Switch should only forward all multicast traffic to a multicast-enabled router, if enabled. Otherwise, the Switch will forward all multicast traffic to any IP router. The default is Disabled.

GVRP Status

Telnet Status

Telnet TCP Port

Number (1-65535)

Web Status

Web TCP Port

Number (1-65535)

RMON Status

Link Aggregation

Algorithm

Use this pull-down menu to enable or disable GVRP on the Switch.

Telnet configuration is Enabled by default. If you do not want to allow configuration of the system through Telnet choose Disabled.

The TCP port number used for Telnet management of the Switch. The "well-known" TCP port for the Telnet protocol is 23.

Web-based management is Enabled by default. If you choose to disable this by selecting

Disabled, you will lose the ability to configure the system through the web interface as soon as these settings are applied.

The TCP port number used for Web-based management of the Switch. The "well-known" TCP port for the Telnet protocol is 80.

Remote monitoring (RMON) of the Switch is Enabled or Disabled here.

Switch 802.1x

Authentication

Protocol

HOL Prevention

Jumbo Frame

The algorithm that the Switch uses to balance the load across the ports that make up the port trunk group is defined by this definition. Choose MAC Source, MAC Destination, MAC Src &

Dest, IP Source, IP Destination or IP Src & Dest (See the Link Aggregation section of this manual).

MAC Address may enable by port or the Switch’s 802.1x function; the default is Disabled. This field must be enabled to view and configure certain windows for 802.1x. More information regarding 802.1x, its functions and implementation can be found later in this section, under the

Port Access Entity folder.

Port-Based 802.1x specifies that ports configured for 802.1x are initialized based on the port number only and are subject to any authorization parameters configured.

MAC-based Authorization specifies that ports configured for 802.1x are initialized based on the port number and the MAC address of the computer being authorized and are then subject to any authorization parameters configured.

The user may use the pull-down menu to choose between radius eap and radius pap for the

802.1x authentication protocol on the Switch. The default setting is radius eap.

If this option is enabled it prevents the forwarding of data to a port that is blocked. Traffic that would normally be sent to the buffer memory of the Switch’s TX queue is dropped so that memory usage is conserved and performance across all ports remains high.

This field will enable or disable the Jumbo Frame function on the Switch. The default is

Disabled. Max. Jumbo frame size = 9216 bytes if this is enabled.

32

xStack DGS-3400 Series Fast Ethernet Switch

IP Address

The IP Address may initially be set using the console interface prior to connecting to it through the Ethernet. If the Switch

IP address has not yet been changed, read the introduction of the xStack DGS-3400 Series CLI Manual or return to Section

4 of this manual for more information. To change IP settings using the web manager you must access the IP Address menu located in the Administration folder.

To configure the Switch's IP address:

Open the Administration folder and click the IP Address menu link. The web manager will display the Switch's current

IP settings in the IP configuration menu, as seen below.

Figure 6- 2. IP Address Settings window

To manually assign the Switch's IP address, subnet mask, and default gateway address:

2. Enter the appropriate IP Address and Subnet Mask.

3. If accessing the Switch from a different subnet from the one it is installed on, enter the IP address of the Default

Gateway. If managing the Switch from the subnet on which it is installed, the user may leave the default address

(0.0.0.0) in this field.

4. If the Switch has no previously configured VLANs, the user can use the default VLAN Name. The default VLAN contains all of the Switch ports as members. If the Switch has previously configured VLANs, the user will need to enter the VLAN ID of the VLAN that contains the port connected to the management station that will access the

Switch. The Switch will allow management access from stations with the same VID listed here.

NOTE: The Switch's factory default IP address is 0.0.0.0 with a subnet mask of 255.0.0.0 and a default gateway of 0.0.0.0.

To use the BOOTP or DHCP protocols to assign the Switch an IP address, subnet mask, and default gateway address:

Use the Get IP From: pull-down menu to choose from BOOTP or DHCP. This selects the method the Switch assigns an

IP address on the next reboot.

33

xStack DGS-3400 Series Fast Ethernet Switch

The IP Address Settings options are:

Parameter Parameter

BOOTP

DHCP

Manual

Subnet Mask

Default

Gateway

VLAN Name

The Switch will send out a BOOTP broadcast request when it is powered up. The BOOTP protocol allows IP addresses, network masks, and default gateways to be assigned by a central BOOTP server. If this option is set, the Switch will first look for a BOOTP server to provide it with this information before using the default or previously entered settings.

The Switch will send out a DHCP broadcast request when it is powered up. The DHCP protocol allows IP addresses, network masks, and default gateways to be assigned by a DHCP server. If this option is set, the Switch will first look for a DHCP server to provide it with this information before using the default or previously entered settings.

Allows the entry of an IP address, Subnet Mask, and a Default Gateway for the Switch.

These fields should be of the form xxx.xxx.xxx.xxx, where each xxx is a number

(represented in decimal form) between 0 and 255. This address should be a unique address on the network assigned for use by the network administrator.

A Bitmask that determines the extent of the subnet that the Switch is on. Should be of the form xxx.xxx.xxx.xxx, where each xxx is a number (represented in decimal) between 0 and

255. The value should be 255.0.0.0 for a Class A network, 255.255.0.0 for a Class B network, and 255.255.255.0 for a Class C network, but custom subnet masks are allowed.

IP address that determines where packets with a destination address outside the current subnet should be sent. This is usually the address of a router or a host acting as an IP gateway. If your network is not part of an intranet, or you do not want the Switch to be accessible outside your local network, you can leave this field unchanged.

This allows the entry of a VLAN Name from which a management station will be allowed to manage the Switch using TCP/IP (in-band via web manager or Telnet). Management stations that are on VLANs other than the one entered here will not be able to manage the

Switch in-band unless their IP addresses are entered in the Security IP Management menu.

If VLANs have not yet been configured for the Switch, the default VLAN contains all of the

Switch's ports. There are no entries in the Security IP Management table, by default, so any management station that can connect to the Switch can access the Switch until a management VLAN is specified or Management Station IP Addresses are assigned.

Click Apply to implement changes made.

Setting the Switch's IP Address using the Console Interface

Each Switch must be assigned its own IP Address, which is used for communication with an SNMP network manager or other TCP/IP application (for example BOOTP, TFTP). The Switch's default IP address is 0.0.0.0. The default Switch IP address can be changed to meet the specification of your networking address scheme.

The IP address for the Switch must be set before the Web-based manager can manage the switch. The Switch IP address can be automatically set using BOOTP or DHCP protocols, in which case the actual address assigned to the Switch must be known. The IP address may be set using the Command Line Interface (CLI) over the console serial port as follows:

Starting at the command line prompt, enter the commands config ipif System ipaddress xxx.xxx.xxx.xxx/

yyy.yyy.yyy.yyy. Where the x's represent the IP address to be assigned to the IP interface named System and the y's represent the corresponding subnet mask.

Alternatively, the user can enter config ipif System ipaddress xxx.xxx.xxx.xxx/z. Where the x's represent the

IP address to be assigned to the IP interface named System and the z represents the corresponding number of subnets in CIDR notation.

The IP interface named System on the Switch can be assigned an IP address and subnet mask, which can then be used to connect a management station to the Switch's Telnet or Web-based management agent.

Successful entry of the command will produce a “Success” message, indicating that the command execution was correctly.

The user may now utilize this address to configure or manage the Switch through Telnet, the Command Line Interface

(CLI) or the Web-based management (GUI).

34

xStack DGS-3400 Series Fast Ethernet Switch

Port Configuration

Click Administration > Port Configuration > Port Configuration to display the following window:

To configure switch ports:

1. Choose the port or sequential range of ports using the From…To… port pull-down menus.

2. Use the remaining pull-down menus to configure the parameters described below:

Figure 6- 3. Port Configuration window

The following parameters can be configured:

Parameter

State <Enabled>

Description

Toggle the State field to either enable or disable a given port or group of ports.

Speed/Duplex <Auto> Toggle the Speed/Duplex field to either select the speed and duplex/halfduplex state of the port. Auto denotes auto-negotiation between 10 and 100

Mbps devices, in full- or half-duplex. The Auto setting allows the port to automatically determine the fastest settings the device the port is connected to can handle, and then to use those settings. The other options are Auto,

10M/Half, 10M/Full, 100M/Half, 100M/Full and 1000/full. There is no automatic adjustment of port settings with any option other than Auto.

Flow Control

Learn

Displays the flow control scheme used for the various port configurations.

Ports configured for full-duplex use 802.3x flow control, half-duplex ports use backpressure flow control, and Auto ports use an automatic selection of the two. The default is Disabled.

Enable or disable MAC address learning for the selected ports. When Enabled, destination and source MAC addresses are automatically listed in the forwarding table. When learning is Disabled, MAC addresses must be manually entered into the forwarding table. This is sometimes done for reasons of security or efficiency. See the section on Forwarding/Filtering for information on entering MAC addresses into the forwarding table. The default setting is Disabled.

Media Type For the Combo ports, if configuring the Combo ports this defines the type of tranport medium used.

Click Apply to implement the new settings on the Switch.

35

xStack DGS-3400 Series Fast Ethernet Switch

Port Description

The Switch supports a port description feature where the user may name various ports on the Switch. To assign names to various ports, click Administration > Port Configuration > Port Description to view the following window:

Figure 6- 4. Port Description Setting window

Use the From and To pull down menu to choose a port or range of ports to describe, and then enter a description of the port(s). Click Apply to set the descriptions in the Port Description Table.

36

xStack DGS-3400 Series Fast Ethernet Switch

User Accounts

Use the User Account Management window to control user privileges. To view existing User Accounts, open the

Administration folder and click on the User Accounts link. This will open the User Account Management window, as shown below.

Figure 6- 5. User Accounts Management window

To add a new user, click on the Add button. To modify or delete an existing user, click on the Modify button for that user.

Figure 6- 6. User Accounts - Add

Add a new user by typing in a User Name, and New Password and retype the same password in the Confirm New

Password. Choose the level of privilege (Admin or User) from the Access Right drop-down menu.

Figure 6- 7. User Accounts Modify Table window - Modify

Modify or delete an existing user account in the User Account Modify Table. To delete the user account, click on the

Delete button. To change the password, type in the New Password and retype it in the Confirm New Password entry field.

The level of privilege (Admin or User) can be viewed in the Access Right field.

37

xStack DGS-3400 Series Fast Ethernet Switch

Port Mirroring

The Switch allows you to copy frames transmitted and received on a port and redirect the copies to another port. You can attach a monitoring device to the mirrored port, such as a sniffer or an RMON probe, to view details about the packets passing through the first port. This is useful for network monitoring and troubleshooting purposes. To view the Port

Mirroring window, click Port Mirroring in the Administration folder.

Figure 6- 8. Setup Port Mirroring window

To configure a mirror port: the source port.

2. Select the Source Direction, Ingress, Egress, or Both and change the Status drop-down menu to Enabled.

3. Click Apply to let the changes take effect.

NOTE: You cannot mirror a fast port onto a slower port. For example, if you try to mirror the traffic from a 100 Mbps port onto a 10 Mbps port, this can cause throughput problems. The port you are copying frames from should always support an equal or lower speed than the port to which you are sending the copies. Also, the target port for the mirroring cannot be a member of a trunk group. Please note a target port and a source port cannot be the same port.

38

xStack DGS-3400 Series Fast Ethernet Switch

System Log Host

The Switch can send Syslog messages to up to four designated servers using the System Log Server. In the

Administration folder, click System Log Setting, to view the window shown below.

Figure 6- 9. System Log Host list

The parameters configured for adding and editing System Log Server settings are the same. See the table below for a description.

Figure 6- 10. System Log Server menu – Edit

Figure 6- 11. System Log Server menu– Add

39

xStack DGS-3400 Series Fast Ethernet Switch

Configure the parameters listed below:

Parameter

Index

Server IP

Severity

Facility

UDP Port (514 or 6000-

65535)

Status

Description

Syslog server settings index (1-4).

The IP address of the Syslog server.

This drop-down menu allows you to select the level of messages that will be sent. The options are Warning, Informational, and All.

Some of the operating system daemons and processes have been assigned

Facility values. Processes and daemons that have not been explicitly assigned a

Facility may use any of the "local use" facilities or they may use the "user-level"

Facility. Those Facilities that have been designated are shown in the following:

Bold font means the facility values that the Switch currently now.

Numerical Facility

Code

8

9

10

11

12

13

14

15

4

5

7

0

1

2

3

16

17

18

19

20

21

22

23 kernel messages user-level messages mail system system daemons security/authorization messages messages generated internally by syslog line printer subsystem network news subsystem

UUCP subsystem clock daemon security/authorization messages

FTP daemon

NTP subsystem log audit log alert clock daemon local use 0 (local0) local use 1 (local1) local use 2 (local2) local use 3 (local3) local use 4 (local4) local use 5 (local5) local use 6 (local6)

local use 7 (local7)

Type the UDP port number used for sending Syslog messages. The default is

514.

Choose Enabled or Disabled to activate or deactivate.

To set the System Log Server configuration, click Apply. To delete an entry from the System Log Server window, click the corresponding X under the Delete heading of the entry you wish to delete. To return to the Current System Log

Servers window, click the Show All System Log Servers link .

40

xStack DGS-3400 Series Fast Ethernet Switch

System Severity Settings

The Switch can be configured to allow alerts be logged or sent as a trap to an SNMP agent or both. The level at which the alert triggers either a log entry or a trap message can be set as well. Use the System Severity Settings menu to set the criteria for alerts. The current settings are displayed below the Settings menu. In the Administration folder, click System

Severity Settings, to view the window shown below.

Figure 6- 12. System Severity Settings

Use the drop-down menus to configure the parameters described below.

Click Apply to implement the new System Severity Settings.

Parameter

System Severity

Severity Level

Description

Choose how the alerts are used from the drop-down menu. Select log to send the alert of the Severity Type configured to the Switch’s log for analysis.

Choose trap to send it to an SNMP agent for analysis. Or select all to send the chosen alert type to an SNMP agent and the Switch’s log for analysis.

Choose what level of alert will trigger sending the log entry or trap message as defined by the Severity Name. Select critical to send only critical events to the

Switch’s log or SNMP agent. Choose warning to send critical and warning events to the Switch’s log or SNMP agent. Select information send informational, warning and critical events to the Switch’s log or SNMP agent.

41

xStack DGS-3400 Series Fast Ethernet Switch

SNTP Settings

Time Settings

To configure the time settings for the Switch, open the Administration folder.

Then the SNTP Settings folder and click on the Time

Settings link, revealing the following window for the user to configure.

The following parameters can be set or are displayed:

Figure 6- 13. Current Time: Status window

Parameter Description

System Boot Time

Current Time

Time Source

Current Time: Status

Displays the time when the Switch was initially started for this session.

Displays the Current Time.

Displays the time source for the system.

SNTP State

Current Time: SNTP Settings

Use this pull-down menu to Enabled or Disabled SNTP.

SNTP Primary Server This is the IP address of the primary server the SNTP information will be taken from.

This is the IP address of the secondary server the SNTP information will be taken from.

SNTP Secondary

Server

SNTP Poll Interval in

Seconds (30-99999)

This is the interval, in seconds, between requests for updated SNTP information.

Current Time: Set Current Time

Year

Month

Day

Time in HH MM SS

Enter the current year, if you want to update the system clock.

Enter the current month, if you would like to update the system clock.

Enter the current day, if you would like to update the system clock.

Enter the current time in hours, minutes, and seconds.

Click Apply to implement your changes.

42

xStack DGS-3400 Series Fast Ethernet Switch

Time Zone and DST

The following are windows used to configure time zones and Daylight Savings time settings for SNTP. Open the

Administration folder, then the SNTP Settings folder and click on the Time Zone and DST link, revealing the following window.

Figure 6- 14. Time Zone and DST Settings window

43

xStack DGS-3400 Series Fast Ethernet Switch

The following parameters can be set:

Parameter

Time Zone and DST Settings

Description

Daylight Saving

Time State

Daylight Saving

Time Offset in

Minutes

Use this pull-down menu to enable or disable the DST Settings.

Use this pull-down menu to specify the amount of time that will constitute your local DST offset - 30, 60, 90, or 120 minutes.

Time Zone Offset from GMT in +/-

HH:MM

Use these pull-down menus to specify your local time zone's offset from Greenwich

Mean Time (GMT.)

DST Repeating Settings - Using repeating mode will enable DST seasonal time adjustment. Repeating mode requires that the DST beginning and ending date be specified using a formula. For example, specify to begin

DST on Saturday during the second week of April and end DST on Sunday during the last week of October.

From: Which Day Enter the week of the month that DST will start.

From: Day of Week Enter the day of the week that DST will start on.

From: Month Enter the month DST will start on.

From: time in

HH:MM

Enter the time of day that DST will start on.

To: Which Day

To: Day of Week

Enter the week of the month the DST will end.

Enter the day of the week that DST will end.

To: Month Enter the month that DST will end.

To: time in HH:MM Enter the time DST will end.

DST Annual Settings - Using annual mode will enable DST seasonal time adjustment. Annual mode requires that the DST beginning and ending date be specified concisely. For example, specify to begin DST on April 3 and end DST on October 14.

From: Month

From: Day

Enter the month DST will start on, each year.

Enter the day of the week DST will start on, each year.

Enter the time of day DST will start on, each year. From: Time in

HH:MM

To: Month Enter the month DST will end on, each year.

To: Day Enter the day of the week DST will end on, each year.

To: Time in HH:MM Enter the time of day that DST will end on, each year.

Click Apply to implement changes made to the Time Zone and DST window.

44

xStack DGS-3400 Series Fast Ethernet Switch

MAC Notification Settings

MAC Notification is used to monitor MAC addresses learned and entered into the forwarding database. To globally set MAC notification on the Switch, open the following window by opening the MAC

Notification Settings in the Administration folder.

Global Settings

The following parameters may be viewed and modified:

Figure 6- 15. MAC Notification Settings

Parameter

State

Interval (sec)

History size

Description

Enable or disable MAC notification globally on the Switch

The time in seconds between notifications.

The maximum number of entries listed in the history log used for notification.

Up to 500 entries can be specified.

Port Settings

To change MAC notification settings for a port or group of ports on the Switch, configure the following parameters.

Parameter

From…To

State

Description

Select a port or group of ports to enable for MAC notification using the pulldown menus.

Enable MAC Notification for the ports selected using the pull-down menu.

Click Apply to implement changes made.

45

xStack DGS-3400 Series Fast Ethernet Switch

TFTP Services

Trivial File Transfer Protocol (TFTP) services allow the Switch's firmware to be upgraded by transferring a new firmware file from a TFTP server to the Switch. A configuration file can also be loaded into the Switch from a TFTP server. Switch configuration settings can be saved to the TFTP server, and a history log can be uploaded from the Switch to the TFTP server. The Switch supports dual image storage for configuration and firmware. The firmware and configuration images are indexed by ID number 1 or 2. To change the boot firmware image, use the Config Firmware Image menu Multiple

Image Services sub-directory. The default Switch settings will use Image ID 1 as the boot configuration or firmware. To update the Switch's firmware or configuration file, open the TFTP Services hyperlink, located in the Administration folder.

.

Figure 6- 16. TFTP Services menu

Configure the following parameters:

Parameter

Active

Image ID

Configuration ID

Server IP Address

File Name

Description

Select a service for the TFTP server to perform from the drop down window:

Download Firmware - Enter the IP address of the TFTP server and specify the location of the new firmware on the TFTP server. Click Start to record the IP address of the TFTP server and to initiate the file transfer.

Download Configuration - Enter the IP address of the TFTP server, and the path and filename for the Configuration file on the TFTP server. Click Start to record the IP address of the TFTP server and to initiate the file transfer.

Upload Configuration - Enter the IP address of the TFTP server and the path and filename for the switch settings on the TFTP server. Click Start to record the IP address of the TFTP server and to initiate the file transfer.

Upload Log - Enter the IP address of the TFTP server and the path and filename for the history log on the TFTP server. Click Start to record the IP address of the TFTP server and to initiate the file transfer.

For firmware downloads, select the Image ID of the firmware. The Switch can hold two firmware images in its memory. Image ID 1 will always be the boot up firmware for the Switch unless specified by the user. Choosing Active will download the firmware to the Boot Up Image ID, depending on the user’s configuration. Information on configuring Image IDs can be found in this section, under the heading Multiple Image Services.

For configuration downloads, select the Image ID of the configuration. The

Switch can hold two configuration images in its memory. Image ID 1 will always be the boot up configuration for the Switch unless specified by the user. Choosing Active will download the configuration to the Boot Up Image ID, depending on the user’s configuration. Information on configuring Image IDs can be found in this section, under the heading Multiple Image Services.

Enter the IP address of the server from which you wish to download firmware.

Enter the path and filename of the firmware or configuration file that you wish to upload or download.

46

xStack DGS-3400 Series Fast Ethernet Switch

Multiple Image Services

The Multiple Image Services folder allows users of the Switch to configure and view information regarding firmware located on the Switch. The Switch allows two firmware images to be stored in its memory and either can be configured to be the boot up firmware for the Switch. For information regarding firmware images located on the Switch, open the

Firmware Information link. The default setting for the Switch’s firmware will have the boot up firmware stored in Image

1, but the user may set either firmware stored to be the boot up firmware by using the Config Firmware Image menu.

Firmware Information

The following screen allows the user to view information about current firmware images stored on the Switch. To access the following screen, click Administration > Multiple Image Services.

Figure 6- 17. Firmware Information window

This window holds the following information:

Parameter

ID

Version

Size

Update Time

From

User

Description

States the image ID number of the firmware in the Switch’s memory. The

Switch can store 2 firmware images for use. Image ID 1 will be the default boot up firmware for the Switch unless otherwise configured by the user.

States the firmware version.

States the size of the corresponding firmware, in bytes.

States the specific time the firmware version was downloaded to the Switch.

States the IP address of the origin of the firmware. There are five ways firmware may be downloaded to the Switch.

R – If the IP address has this letter attached to it, it denotes a firmware upgrade through the Console Serial Port (RS-232).

T - If the IP address has this letter attached to it, it denotes a firmware upgrade through Telnet.

S - If the IP address has this letter attached to it, it denotes a firmware upgrade through the Simple Network Management Protocol (SNMP).

W - If the IP address has this letter attached to it, it denotes a firmware upgrade through the web-based management interface.

SIM – If the IP address has this letter attached to it, it denotes a firmware upgrade through the Single IP Management feature.

States the user who downloaded the firmware. This field may read

“Anonymous” or “Unknown” for users that are not identified.

47

xStack DGS-3400 Series Fast Ethernet Switch

Ping Test

Ping is a small program that sends ICMP Echo packets to the IP address you specify. The destination node then responds to or "echoes" the packets sent from the Switch. This is very useful to verify connectivity between the Switch and other nodes on the network.

Figure 6- 18. Ping Test window

The user may use Infinite times radio button, in the Repeat Pinging for field, which will tell the ping program to keep sending ICMP Echo packets to the specified IP address until the program is stopped. The user may opt to choose a specific number of times to ping the Target IP Address by clicking its radio button and entering a number between 1 and 255. Click

Start to initiate the Ping program.

Safeguard Engine

Periodically, malicious hosts on the network will attack the Switch by utilizing packet flooding (ARP Storm) or other methods. These attacks may increase the CPU utilization beyond its capability. To alleviate this problem, the Safeguard

Engine function was added to the Switch’s software.

Safeguard Engine can help the overall operability of the Switch by minimizing the workload of the Switch while the attack is ongoing, thus making it capable to forward essential packets over its network in a limited bandwidth. When the Switch either (a) receives too many packets to process or (b) exerts too much memory, it will enter an Exhausted mode. When in this mode, the Switch will perform the following tasks to mimimize the CPU usage:

1. It will limit bandwidth of receiving ARP packets. The user may implement this in two ways, by using the Mode pull down menu in the screen below: eliminate all unnecessary ARP packets while allowing the essential ARP packets to pass through to the

Switch’s CPU.

Fuzzy is chosen, the Switch will mimimze the ARP packet bandwidth received by the switch by adjusting the bandwidth for all ARP packets, whether destined for the Switch or not. The Switch uses an internal algorithm to filter ARP packets through, with a higher percentage set aside for ARP packets destined for the Switch.

2. It will limit the bandwidth of IP packets received by the Switch. The user may implement this in two ways, by using the Mode pull down menu in the screen below:

Strict is chosen, the Switch will stop receiving all unnecessary broadcast IP packets, even if the high CPU utilization is not caused by the high receival rate of broadcast IP packets.

Fuzzy is chosen, the Switch will mimimze the IP packet bandwidth received by the Switch by adjusting the bandwidth for all IP packets, by setting a acceptable bandwidth for both unicast and broadcast IP packets. The Switch uses an internal algorithm to filter IP packets through while adjusting the bandwidth dynamically.

48

xStack DGS-3400 Series Fast Ethernet Switch

IP packets may also be limited by the Switch by configuring only certain IP addresses to be accepted. This method can be accomplished through the CPU Interface Filtering mechanism explained in the previous section. Once the user configures these acceptable IP addresses, other packets containing different IP addresses will be dropped by the Switch, thus limiting the bandwidth of IP packets. To keep the process moving fast, be sure not to add many conditions on which to accept these acceptable IP addresses and their packets, this limiting the CPU utilization.

Once in Exhausted mode, the packet flow will decrease by half of the level that caused the Switch to enter Exhausted mode. After the packet flow has stabilized, the rate will initially increase by 25% and then return to a normal packet flow.

NOTICE: When Safeguard Engine is enabled, the Switch will allot bandwidth to various traffic flows (ARP, IP) using the FFP (Fast Filter Processor) metering table to control the

CPU utilization and limit traffic. This may limit the speed of routing traffic over the network.

Safeguard Engine Status

To view the current Safeguard Engine Status for the Switch, click Administration > Safeguard Engine > Safeguard

Engine Status

Figure 6- 19. Safeguard Engine Status display

The Safeguard Engine Status window is a read-only field that will state the current Safeguard Engine mode of the Switch.

This field may read “normal mode” or “exhausted mode”.

Enable/Disable Safeguard Engine

To enable Safeguard Engine or configure advanced Safeguard Engine settings for the Switch, click Configuration >

Safeguard Engine > Safeguard Engine Settings, which will open the following window.

Figure 6- 20. Safeguard Engine State menu

To enable the Safeguard Engine option, select Enabled with the drop-down State menu and click the Apply button.

49

xStack DGS-3400 Series Fast Ethernet Switch

To configure the advanced settings for Safeguard Engine, click the Advanced Settings button to view the following menu.

Figure 6- 21. Safeguard Engine (Advanced) Settings menu

To configure, set the following parameters and click Apply.

Parameter

State

Rising

Falling

Trap / Log

Mode

Description

Use the pull-down menu to globally enable or disable Safeguard Engine settings for the Switch.

Used to configure the acceptable level of CPU utilization before the Safeguard

Engine mechanism is enabled. Once the CPU utilization reaches this percentage level, the Switch will move into Safeguard Engine state, based on the parameters provided in this window.

Used to configure the acceptable level of CPU utilization as a percentage, where the Switch leaves the Safeguard Engine state and returns to normal mode.

Use the pull-down menu to enable or disable the sending of messages to the device’s SNMP agent and switch log once the Safeguard Engine has been activated by a high CPU utilization rate.

Used to select the type of Safeguard Engine to be activated by the Switch when the CPU utilization reaches a high rate. The user may select:

Fuzzy – If selected, this function will instruct the Switch to minimize the IP and ARP traffic flow to the CPU by dynamically allotting an even bandwidth to all traffic flows.

Strict – If selected, this function will stop accepting all ARP packets not intended for the Switch, and will stop receiving all unnecessary broadcast IP packets, until the storm has subsided.

The default setting is Fuzzy mode.

50

xStack DGS-3400 Series Fast Ethernet Switch

Static ARP Settings

The Address Resolution Protocol (ARP) is a TCP/IP protocol that converts IP addresses into physical addresses. This table allows network managers to view, define, modify and delete ARP information for specific devices.

Static entries can be defined in the ARP Table. When static entries are defined, a permanent entry is entered and is used to translate IP address to MAC addresses.

To open the Static ARP Table open the Administration folder, and then open the Static ARP folder and click on the

Static ARP Settings link.

Figure 6- 22. Static ARP Settings window

To add a new entry, click the Add button, revealing the following screen to configure:

Figure 6- 23. Static ARP Settings – Add window

To modify a current entry, click the corresponding Modify button of the entry to be modified, revealing the following screen to configure:

Figure 6- 24. Static ARP Settings – Edit window

The following fields can be set or viewed:

Parameter

IP Address

Description

The IP address of the ARP entry. This field cannot be edited in the Static ARP

Settings – Edit window.

The MAC address of the ARP entry. MAC Address

After entering the IP Address and MAC Address of the Static ARP entry, click Apply to implement the new entry. To completely clear the Static ARP Settings, click the Clear All button.

51

xStack DGS-3400 Series Fast Ethernet Switch

Static IPv6 ARP Settings

Static ARP entries can be defined for IPv6 addresses. This will create a permanent entry is entered and is used to translate

IPv6 address to MAC addresses.

To open the Static IPv6 ARP Table open the Administration folder, and then open the Static ARP folder and click on the Static IPv6 ARP Settings link.

Figure 6- 25. Static IPv6 ARP Settings table

To remove an entry, click the Delete button for the entry being removed. To completely clear the Static IPv6 ARP

Settings, click the Clear All button. To add a new entry, click the Add button, revealing the following screen to configure:

Figure 6- 26. Static IPv6 ARP Settings – Add menu

The following fields can be set or viewed:

Parameter

IPv6 Address

Description

The IPv6 address of the ARP entry. Specify the address using the format as ipv6address (ipv6address is hexadecimal number, for example

1234::5D7F/32).

The MAC address of the IPv6 ARP entry. MAC Address

After entering the IPv6 Address and MAC Address of the Static IPv6 ARP entry, click Apply to implement the new entry.

52

xStack DGS-3400 Series Fast Ethernet Switch

Routing Table

The Switch supports static routing for IP and IPv6 formated addressing. Access both menus in the Routing Table folder.

Static/Default IP Route Settings

Entries into the Switch’s forwarding table can be made using both MAC addresses and IP addresses. Static IP forwarding is accomplished by the entry of an IP address into the Switch’s Static IP Routing Table. To view the following window, click Administration > Routing Table > Static/Default Route.

Figure 6- 27. Static/Default Route Settings window

This window shows the following values:

Parameter

IP Address

Subnet Mask

Gateway

Metric

Protocol

Backup State

Description

The IP address of the Static/Default Route.

The corresponding Subnet Mask of the IP address entered into the table.

The corresponding Gateway of the IP address entered into the table.

Represents the metric value of the IP interface entered into the table. This field may read a number between 1-65535.

Represents the protocol used for the Routing Table entry of the IP interface.

Represents the Backup state that this IP interface is configured for. This field may read Primary or Backup.

Delete

Click the button if you would like to delete this entry from the Static/Default

Route Settings table.

53

xStack DGS-3400 Series Fast Ethernet Switch

To enter an IP Interface into the Switch’s Static/Default Route Settings window, click the Add button, revealing the following window to configure.

Figure 6- 28. Static/Default Route Settings – Add window

The following fields can be set:

Parameter

IP Address

Subnet Mask

Gateway

Metric (1-65535)

Backup State

Description

Allows the entry of an IP address that will be a static entry into the Switch’s Routing

Table.

Allows the entry of a subnet mask corresponding to the IP address above.

Allows the entry of an IP address of a gateway for the IP address above.

Allows the entry of a routing protocol metric representing the number of routers between the Switch and the IP address above.

The user may choose between Primary and Backup. If the Primary Static/Default

Route fails, the Backup Route will support the entry. Please take note that the

Primary and Backup entries cannot have the same Gateway.

Click Apply to implement changes made.

54

xStack DGS-3400 Series Fast Ethernet Switch

Static IPv6 Route Settings

A static entry of an IPv6 address can be entered into the Switch’s routing table for IPv6 formatted addresses. To view the following window, click Administration > Routing Table > IPv6 Static Route.

Figure 6- 29. IPv6 Static Route Settings list

This window shows the following values:

Parameter Description

IPv6 Address/Netmask The IPv6 address and corresponding Subnet Mask of the IPv6 static route entry.

Gateway

Metric (1-65535)

Protocol

Delete

The corresponding IPv6 address for the next hop Gateway address in IPv6 format.

The metric of the IPv6 interface entered into the table representing the number of routers between the Switch and the IPv6 address above. Metric values allowed are between 1-65535.

Represents the status (default or static) for the IPv6 routing table entry.

Click the button if you would like to delete this entry from the list.

55

xStack DGS-3400 Series Fast Ethernet Switch

To enter an IPv6 Interface into the IPv6 Static Route list, click the Add button, revealing the following window to configure.

Figure 6- 30. Static/Default Route Settings – Add menu

Click to select the default option if this will be the default IPv6 route. Choosing this option will allow the user to configure the default gateway for the next hop router only.

The following fields can be set:

Parameter Description

IPv6 Address/Netmask Specify the address and mask information using the format as ipv6address / prefix length (ipv6address is hexadecimal number, prefix length is decimal number, for example 1234::5D7F/32).

Next Hop Address

Metric (1-65535)

Enter the IPv6 address for the next hop Gateway address in IPv6 format. default

The metric representing the number of routers between the Switch and the IPv6 address above.

Select the default option to define the entry as a 1 hop IPv6 default route.

Click Apply to implement changes made.

DHCP Auto Configuration Settings

This window is used to enable the DHCP Autoconfiguration feature on the Switch. When enabled, the Switch is instructed to receive a configuration file from a TFTP server, which will set the Switch to become a DHCP client automatically on boot up. To employ this method, the DHCP server must be set up to deliver the TFTP server Ip address and configuration file name information in the DHCP reply packet. The TFTP server must be up and running and hold the necessary configuration file stored in its base directory when the request is received from the Switch. For more information about loading a configuration file for use by a client, see the DHCP server and/or TFTP server software instructions. The user may also cunsult the Upload screen description located in the Maintenance section of this manual.

If the Switch is unable to complete the DHCP auto configuration, the previously saved configuration file present in the

Switch’s memory will be used.

Figure 6- 31. DHCP Auto Configuration Settings window

To enable the DHCP Auto Configuration State, use the pull-down menu to choose Enable and click the Apply button.

56

xStack DGS-3400 Series Fast Ethernet Switch

SNMP Settings

Simple Network Management Protocol (SNMP) is an OSI Layer 7 (Application Layer) designed specifically for managing and monitoring network devices. SNMP enables network management stations to read and modify the settings of gateways, routers, switches, and other network devices. Use SNMP to configure system features for proper operation, monitor performance and detect potential problems in the Switch, switch group or network.

Managed devices that support SNMP include software (referred to as an agent), which runs locally on the device. A defined set of variables (managed objects) is maintained by the SNMP agent and used to manage the device. These objects are defined in a Management Information Base (MIB), which provides a standard presentation of the information controlled by the on-board SNMP agent. SNMP defines both the format of the MIB specifications and the protocol used to access this information over the network.

The DGS-3400 Series supports the SNMP versions 1, 2c, and 3. The three versions of SNMP vary in the level of security provided between the management station and the network device.

In SNMP v.1 and v.2, user authentication is accomplished using 'community strings', which function like passwords. The remote user SNMP application and the Switch SNMP must use the same community string. SNMP packets from any station that has not been authenticated are ignored (dropped).

The default community strings for the Switch used for SNMP v.1 and v.2 management access are:

public - Allows authorized management stations to retrieve MIB objects.

private - Allows authorized management stations to retrieve and modify MIB objects.

SNMPv3 uses a more sophisticated authentication process that is separated into two parts. The first part is to maintain a list of users and their attributes that are allowed to act as SNMP managers. The second part describes what each user on that list can do as an SNMP manager.

The Switch allows groups of users to be listed and configured with a shared set of privileges. The SNMP version may also be set for a listed group of SNMP managers. Thus, you may create a group of SNMP managers that are allowed to view read-only information or receive traps using SNMPv1 while assigning a higher level of security to another group, granting read/write privileges using SNMPv3.

Using SNMPv3 individual users or groups of SNMP managers can be allowed to perform or be restricted from performing specific SNMP management functions. The functions allowed or restricted are defined using the Object Identifier (OID) associated with a specific MIB. An additional layer of security is available for SNMPv3 in that SNMP messages may be encrypted. To read more about how to configure SNMPv3 settings for the Switch read the next section.

Traps

Traps are messages that alert network personnel of events that occur on the Switch. The events can be as serious as a reboot (someone accidentally turned OFF the Switch), or less serious like a port status change. The Switch generates traps and sends them to the trap recipient (or network manager). Typical traps include trap messages for Authentication Failure,

Topology Change and Broadcast\Multicast Storm.

MIBs

The Switch in the Management Information Base (MIB) stores management and counter information. The Switch uses the standard MIB-II Management Information Base module. Consequently, values for MIB objects can be retrieved from any

SNMP-based network management software. In addition to the standard MIB-II, the Switch also supports its own proprietary enterprise MIB as an extended Management Information Base. Specifying the MIB Object Identifier may also retrieve the proprietary MIB. MIB values can be either read-only or read-write.

The DGS-3400 Series incorporates a flexible SNMP management for the switching environment. SNMP management can be customized to suit the needs of the networks and the preferences of the network administrator. Use the SNMP V3 menus to select the SNMP version used for specific tasks.

The DGS-3400 Series supports the Simple Network Management Protocol (SNMP) versions 1, 2c, and 3. The administrator can specify the SNMP version used to monitor and control the Switch. The three versions of SNMP vary in the level of security provided between the management station and the network device.

SNMP settings are configured using the menus located on the SNMP V3 folder of the web manager. Workstations on the network that are allowed SNMP privileged access to the Switch can be restricted with the Management Station IP Address menu.

57

xStack DGS-3400 Series Fast Ethernet Switch

SNMP User Table

The SNMP User Table displays all of the SNMP User's currently configured on the Switch.

In the SNMP Manager folder, located in the Administration folder, click on the SNMP User Table link. This will open the SNMP User Table window, as shown below.

Figure 6- 32. SNMP User Table window

To delete an existing SNMP User Table entry, click the X below the Delete heading corresponding to the entry you wish to delete.

To display the detailed entry for a given user, click on the View button. This will open the SNMP User Table Display window, as shown below.

Figure 6- 33. SNMP User Table Display

The following parameters are displayed:

Parameter

User Name

Group Name

SNMP Version

Auth-Protocol

Priv-Protocol

Description

An alphanumeric string of up to 32 characters. This is used to identify the

SNMP users.

This name is used to specify the SNMP group created can request SNMP messages.

V1 - Indicates that SNMP version 1 is in use.

V2 - Indicates that SNMP version 2 is in use.

V3 - Indicates that SNMP version 3 is in use.

None - Indicates that no authorization protocol is in use.

MD5 - Indicates that the HMAC-MD5-96 authentication level will be used.

SHA - Indicates that the HMAC-SHA authentication protocol will be used.

None - Indicates that no authorization protocol is in use.

DES - Indicates that DES 56-bit encryption is in use based on the CBC-DES

(DES-56) standard.

58

xStack DGS-3400 Series Fast Ethernet Switch

To return to the SNMP User Table, click the Show All SNMP User Table Entries link. To add a new entry to the SNMP

User Table Configuration window, click on the Add button on the SNMP User Table window. This will open the

SNMP User Table Configuration window, as shown below.

Figure 6- 34. SNMP User Table Configuration window

To implement changes made, click Apply. To return to the SNMP User Table, click the Show All SNMP User Table

Entries link.

SNMP View Table

The SNMP View Table is used to assign views to community strings that define which MIB objects can be accessed by a remote SNMP manager. To view the SNMP View Table window, open the SNMP Manager folder under

Administration and click the SNMP View Table entry. The following window should appear:

Figure 6- 35. SNMP View Table window

To delete an existing SNMP View Table entry, click the X in the Delete column corresponding to the entry you wish to delete. To create a new entry, click the Add button and a separate window will appear.

59

xStack DGS-3400 Series Fast Ethernet Switch

Figure 6- 36. SNMP View Table Configuration window

The SNMP Group created with this table maps SNMP users (identified in the SNMP User Table) to the views created in the previous window.

The following parameters can set:

Parameter

View Name

Subtree OID

View Type

Description

Type an alphanumeric string of up to 32 characters. This is used to identify the new SNMP view being created.

Type the Object Identifier (OID) Subtree for the view. The OID identifies an object tree (MIB tree) that will be included or excluded from access by an

SNMP manager.

Select Included to include this object in the list of objects that an SNMP manager can access. Select Excluded to exclude this object from the list of objects that an SNMP manager can access.

To implement your new settings, click Apply. To return to the SNMP View Table, click the Show All SNMP View Table

Entries link.

SNMP Group Table

An SNMP Group created with this table maps SNMP users (identified in the SNMP User Table) to the views created in the previous menu. To view the SNMP Group Table window, open the SNMP Manager folder in the Administration folder and click the SNMP Group Table entry. The following window should appear:

Figure 6- 37. SNMP Group Table window

To delete an existing SNMP Group Table entry, click the corresponding X under the Delete heading.

60

xStack DGS-3400 Series Fast Ethernet Switch

To display the current settings for an existing SNMP Group Table entry, click the hyperlink for the entry under the Group

Name.

Figure 6- 38. SNMP Group Table Configuration window

To add a new entry to the Switch's SNMP Group Table, click the Add button in the upper left-hand corner of the SNMP

Group Table window. This will open the SNMP Group Table Configuration window, as shown below.

Figure 6- 39. SNMP Group Table Configuration window

61

xStack DGS-3400 Series Fast Ethernet Switch

The following parameters can set:

Parameter

Group Name

Read View Name

Write View Name

Notify View Name

Security Model

Security Level

Description

Type an alphanumeric string of up to 32 characters. This is used to identify the new SNMP group of SNMP users.

This name is used to specify the SNMP group created can request SNMP messages.

Specify a SNMP group name for users that are allowed SNMP write privileges to the Switch's SNMP agent.

Specify a SNMP group name for users that can receive SNMP trap messages generated by the Switch's SNMP agent.

SNMPv1 - Specifies that SNMP version 1 will be used.

SNMPv2 - Specifies that SNMP version 2c will be used. The SNMPv2 supports both centralized and distributed network management strategies. It includes improvements in the Structure of Management Information (SMI) and adds some security features.

SNMPv3 - Specifies that the SNMP version 3 will be used. SNMPv3 provides secure access to devices through a combination of authentication and encrypting packets over the network.

The Security Level settings only apply to SNMPv3.

NoAuthNoPriv - Specifies that there will be no authorization and no encryption of packets sent between the Switch and a remote SNMP manager.

AuthNoPriv - Specifies that authorization will be required, but there will be no encryption of packets sent between the Switch and a remote SNMP manager.

AuthPriv - Specifies that authorization will be required, and that packets sent between the Switch and a remote SNMP manger will be encrypted.

To implement your new settings, click Apply. To return to the SNMP Group Table, click the Show All SNMP Group

Table Entries link.

SNMP Community Table Configuration

Use this table to create an SNMP community string to define the relationship between the SNMP manager and an agent.

The community string acts like a password to permit access to the agent on the Switch. One or more of the following characteristics can be associated with the community string:

An Access List of IP addresses of SNMP managers that are permitted to use the community string to gain access to the

Switch's SNMP agent.

Any MIB view that defines the subset of all MIB objects will be accessible to the SNMP community.

Read/write or read-only level permission for the MIB objects accessible to the SNMP community.

To configure SNMP Community entries, open the SNMP Manager folder, (located in the Administration folder) and click the SNMP Community Table link, which will open the following window:

62

xStack DGS-3400 Series Fast Ethernet Switch

Figure 6- 40. SNMP Community Table Configuration window

The following parameters can set:

Parameter

Community Name

View Name

Access Right

Description

Type an alphanumeric string of up to 32 characters that is used to identify members of an SNMP community. This string is used like a password to give remote SNMP managers access to MIB objects in the Switch's SNMP agent.

Type an alphanumeric string of up to 32 characters that is used to identify the group of MIB objects that a remote SNMP manager is allowed to access on the Switch. The view name must exist in the SNMP View Table.

Read Only - Specifies that SNMP community members using the community string created can only read the contents of the MIBs on the Switch.

Read Write - Specifies that SNMP community members using the community string created can read from, and write to the contents of the MIBs on the

Switch.

To implement the new settings, click Apply. To delete an entry from the SNMP Community Table, click the under the Delete heading, corresponding to the entry you wish to delete.

63

xStack DGS-3400 Series Fast Ethernet Switch

SNMP Host Table

Use the SNMP Host Table window to set up SNMP trap recipients. Open the SNMP Manager folder, (located in the

Adminstation folder) and click on the SNMP Host Table link. This will open the SNMP Host Table window, as shown below. To delete an existing SNMP Host Table entry, click the corresponding X under the Delete heading. To display the current settings for an existing SNMP Group Table entry, click the blue link for the entry under the Host IP Address heading.

Figure 6- 41. SNMP Host Table window

To add a new entry to the Switch's SNMP Host Table, click the Add button in the upper left-hand corner of the window.

This will open the SNMP Host Table Configuration window, as shown below.

Figure 6- 42. SNMP Host Table Configuration window

The following parameters can set:

Parameter

Host IP Address

SNMP Version

Description

Type the IP address of the remote management station that will serve as the

SNMP host for the Switch.

V1 - To specifies that SNMP version 1 will be used.

V2 - To specify that SNMP version 2 will be used.

V3-NoAuth-NoPriv - To specify that the SNMP version 3 will be used, with a

NoAuth-NoPriv security level.

V3-Auth-NoPriv - To specify that the SNMP version 3 will be used, with an

Auth-NoPriv security level.

V3-Auth-Priv - To specify that the SNMP version 3 will be used, with an Auth-

Priv security level.

Type in the community string or SNMP V3 user name as appropriate. Community String or SNMP

V3 User Name

To implement your new settings, click Apply. To return to the SNMP Host Table, click the Show All SNMP Host Table

Entries link.

64

xStack DGS-3400 Series Fast Ethernet Switch

SNMP Engine ID

The Engine ID is a unique identifier used for SNMP V3 implementations. This is an alphanumeric string used to identify the SNMP engine on the Switch. To display the Switch's SNMP Engine ID, open the SNMP Manger folder, (located in the Administration) folder and click on the SNMP Engine ID link. This will open the SNMP Engine ID Configuration window, as shown below.

Figure 6- 43. SNMP Engine ID Configuration window

To change the Engine ID, type the new Engine ID in the space provided and click the Apply button.

65

xStack DGS-3400 Series Fast Ethernet Switch

IP-MAC Binding

The IP-MAC binding feature is a security measure that restricts access to a Switch to authorized users. Only the authorized client can access a Switch’s port by comparing a pre-configured IP/MAC matching database to the IP/MAC match extracted form ARP request or acknowledgement packets. If the comparison test fails, the user is not authorized, the packet is dropped and the user is effectively blocked from access. IP-MAC binding may be enabled on a per port basis. IP-MAC binding is useful for preventing IP spoofing and other abuses.

IP-MAC Binding per Port

The IP-MAC Ports Settings menu is used to enable IP-MAC binding on a per port basis. Ports that are enabled will apply the IP-MAC check to ingress packets for the port. The IP-MAC database used for the check must be set up with the IP-

MAC Binding Table (see below).

To enable or disable IP-MAC binding on specific ports, click IP-MAC Binding Port in the IP-MAC Binding folder on the Administration Menu to open the IP-MAC Binding Ports Setting window. Select a port or a range of ports with the

From and To fields. Enable or disable the port with the State field. Click Apply to save changes.

Figure 6- 44. IP-MAC Binding Ports

66

xStack DGS-3400 Series Fast Ethernet Switch

IP-MAC Binding Table

The window shown below can be used to create IP-MAC binding entries. Click the IP-MAC Binding Table on the

IP-MAC Binding folder on the Configuration menu to view the IP-MAC Binding Setting window. Enter the IP and

MAC addresses of the authorized users in the appropriate fields and click Add. To modify either the IP address or the

MAC address of the binding entry, make the desired changes in the appropriate field and Click Modify. To find an IP-

MAC binding entry, enter the IP and MAC addresses and click Find. To delete an entry click Delete. To clear all the entries from the table click Delete All.

Figure 6- 45. IP-MAC Binding Table and Setting menu

Figure 6- 46. IP-MAC Blocked Table and configuration menu

IP-MAC Binding Blocked

To view unauthorized devices that have been blocked by IP-MAC binding restrictions open the IP-MAC Binding Blocked window show below. Click IP-MAC Binding Blocked in the IP-MAC Blocked folder in the Administration menu to open the IP-MAC Binding Blocked window.

67

xStack DGS-3400 Series Fast Ethernet Switch

Single IP Management (SIM) Overview

Simply put, D-Link Single IP Management is a concept that will stack switches together over Ethernet instead of using stacking ports or modules. There are some advantages in implementing the "Single IP Management" feature:

1. SIM can simplify management of small workgroups or wiring closets while scaling the network to handle increased bandwidth demand.

2. SIM can reduce the number of IP address needed in your network.

3. SIM can eliminate any specialized cables for stacking connectivity and remove the distance barriers that typically limit your topology options when using other stacking technology.

Switches using D-Link Single IP Management (labeled here as SIM) must conform to the following rules:

SIM is an optional feature on the Switch and can easily be enabled or disabled through the Command Line Interface or

Web Interface. SIM grouping has no effect on the normal operation of the Switch in the user's network.

There are three classifications for switches using SIM. The Commander Switch (CS), which is the master switch of the group, Member Switch (MS), which is a switch that is recognized by the CS a member of a SIM group, and a Candidate

Switch (CaS), which is a Switch that has a physical link to the SIM group but has not been recognized by the CS as a member of the SIM group.

A SIM group can only have one Commander Switch (CS).

All switches in a particular SIM group must be in the same IP subnet (broadcast domain). Members of a SIM group cannot cross a router.

A SIM group accepts up to 32 switches (numbered 1-31), not including the Commander Switch (numbered 0).

There is no limit to the number of SIM groups in the same IP subnet (broadcast domain), however a single switch can only belong to one group.

If multiple VLANs are configured, the SIM group will only utilize the default VLAN on any switch.

SIM allows intermediate devices that do not support SIM. This enables the user to manage switches that are more than one hop away from the CS.

The SIM group is a group of switches that are managed as a single entity. The xStack DGS-3400 Series switch may take on three different roles:

1. Commander Switch (CS) - This is a switch that has been manually configured as the controlling device for a group, and takes on the following characteristics:

It has an IP Address.

It is not a command switch or member switch of another Single IP group.

It is connected to the member switches through its management VLAN.

2. Member Switch (MS) - This is a switch that has joined a single IP group and is accessible from the CS, and it takes on the following characteristics:

It is not a CS or MS of another IP group.

It is connected to the CS through the CS management VLAN.

3. Candidate Switch (CaS) - This is a switch that is ready to join a SIM group but is not yet a member of the SIM group. The Candidate Switch may join the SIM group of the xStack DGS-3400 Series switch by manually configuring it to be a MS of a SIM group. A switch configured as a CaS is not a member of a SIM group and will take on the following characteristics:

It is not a CS or MS of another Single IP group.

It is connected to the CS through the CS management VLAN

The following rules also apply to the above roles:

• Each device begins in a Candidate state.

• CS's must change their role to CaS and then to MS, to become a MS of a SIM group. Thus, the CS cannot directly be converted to a MS.

68

xStack DGS-3400 Series Fast Ethernet Switch

The user can manually configure a CS to become a CaS.

A MS can become a CaS by:

Being configured as a CaS through the CS.

If report packets from the CS to the MS time out.

The user can manually configure a CaS to become a CS

• The CaS can be configured through the CS to become a MS.

After configuring one switch to operate as the CS of a SIM group, additional xStack DGS-3400 Series switch may join the group by manually configuring the Switch to be a MS. The CS will then serve as the in band entry point for access to the

MS. The CS's IP address will become the path to all MS's of the group and the CS's Administrator's password, and/or authentication will control access to all MS's of the SIM group.

With SIM enabled, the applications in the CS will redirect the packet instead of executing the packets. The applications will decode the packet from the administrator, modify some data, then send it to the MS. After execution, the CS may receive a response packet from the MS, which it will encode and send it back to the administrator.

When a CaS becomes a MS, it automatically becomes a member of the first SNMP community (include read/write and read only) to which the CS belongs. However, if a MS has its own IP address, it can belong to SNMP communities to which other switches in the group, including the CS, do not belong.

69

xStack DGS-3400 Series Fast Ethernet Switch

SIM Using the Web Interface

All xStack DGS-3400 Series Switches are set as Candidate (CaS) switches as their factory default configuration and Single

IP Management will be disabled. To enable SIM for the Switch using the Web interface, go to the Single IP Management folder and click the SIM Settings link, revealing the following window.

Figure 6- 47. SIM Settings window (disabled)

Change the SIM State to Enabled using the pull down menu and click Apply. The screen will then refresh and the SIM

Settings window will look like this:

Figure 6- 48. SIM Settings window (enabled)

Parameter

SIM State

Role State

Discovery Interval

Holdtime

Description

Use the pull-down menu to either enable or disable the SIM state on the

Switch. Disabled will render all SIM functions on the Switch inoperable.

Use the pull-down menu to change the SIM role of the Switch. The two choices are:

Candidate - A Candidate Switch (CaS) is not the member of a SIM group but is connected to a Commander Switch. This is the default setting for the SIM role of the DGS-3400 Series.

Commander - Choosing this parameter will make the Switch a Commander

Switch (CS). The user may join other switches to this Switch, over Ethernet, to be part of its SIM group. Choosing this option will also enable the Switch to be configured for SIM.

The user may set the discovery protocol interval, in seconds that the Switch will send out discovery packets. Returning information to a Commander Switch will include information about other switches connected to it. (Ex. MS, CaS).

The user may set the Discovery Interval from 30 to 90 seconds.

This parameter may be set for the time, in seconds; the Switch will hold information sent to it from other switches, utilizing the Discovery Interval. The user may set the hold time from 100 to 255 seconds.

Click Apply to implement the settings changed. After enabling the Switch to be a Commander Switch (CS), the Single IP

Management folder will then contain three added links to aid the user in configuring SIM through the web, including

Topology, Firmware Upgrade and Configuration Backup/Restore.

70

xStack DGS-3400 Series Fast Ethernet Switch

Topology

The Topology window will be used to configure and manage the Switch within the SIM group and requires Java script to function properly on your computer.

The Java Runtime Environment on your server should initiate and lead you to the topology window, as seen below.

Figure 6- 49. Single IP Management window - Tree View

The Tree View window holds the following information under the Data tab:

Parameter

Device Name

Local Port

Speed

Remote Port

MAC Address

Model Name

Description

This field will display the Device Name of the switches in the SIM group configured by the user. If no device is configured by the name, it will be given the name default and tagged with the last six digits of the MAC Address to identify it.

Displays the number of the physical port on the CS that the MS or CaS is connected to. The CS will have no entry in this field.

Displays the connection speed between the CS and the MS or CaS.

Displays the number of the physical port on the MS or CaS that the CS is connected to. The CS will have no entry in this field.

Displays the MAC Address of the corresponding Switch.

Displays the full Model Name of the corresponding Switch.

71

xStack DGS-3400 Series Fast Ethernet Switch

To view the Topology Map, click the View menu in the toolbar and then Topology, which will produce the following screen. The Topology View will refresh itself periodically (20 seconds by default).

Figure 6- 50. Topology view

This screen will display how the devices within the Single IP Management Group connect to other groups and devices.

Possible icons in this screen are as follows:

Icon Description

Group

Layer 2 commander switch

Layer 3 commander switch

Commander switch of other group

Layer 2 member switch.

Layer 3 member switch

Member switch of other group

Layer 2 candidate switch

Layer 3 candidate switch

Unknown device

Non-SIM devices

72

xStack DGS-3400 Series Fast Ethernet Switch

Tool Tips

In the Topology view window, the mouse plays an important role in configuration and in viewing device information.

Setting the mouse cursor over a specific device in the topology window (tool tip) will display the same information about a specific device as the Tree view does. See the window below for an example.

Figure 6- 51. Device Information Utilizing the Tool Tip

Setting the mouse cursor over a line between two devices will display the connection speed between the two devices, as shown below.

Figure 6- 52. Port Speed Utilizing the Tool Tip

73

xStack DGS-3400 Series Fast Ethernet Switch

Right Click

Right clicking on a device will allow the user to perform various functions, depending on the role of the Switch in the SIM group and the icon associated with it.

Group Icon

Figure 6- 53. Right Clicking a Group Icon

The following options may appear for the user to configure:

Collapse - to collapse the group that will be represented by a single icon.

Expand - to expand the SIM group, in detail.

Property - to pop up a window to display the group information.

Figure 6- 54. Property window

74

xStack DGS-3400 Series Fast Ethernet Switch

Commander Switch Icon

Figure 6- 55. Right Clicking a Commander Icon

The following options may appear for the user to configure:

Collapse - to collapse the group that will be represented by a single icon.

Expand - to expand the SIM group, in detail.

Property - to pop up a window to display the group information.

Member Switch Icon

Figure 6- 56. Property window

Figure 6- 57. Right Clicking a Member icon

The following options may appear for the user to configure:

75

xStack DGS-3400 Series Fast Ethernet Switch

Collapse - to collapse the group that will be represented by a single icon.

Expand - to expand the SIM group, in detail.

Remove from group - remove a member from a group.

Configure - launch the web management to configure the Switch.

Property - to pop up a window to display the device information.

Candidate Switch Icon

Figure 6- 58. Property window

Figure 6- 59. Right Clicking a Candidate icon

The following options may appear for the user to configure:

Collapse - to collapse the group that will be represented by a single icon.

Expand - to expand the SIM group, in detail.

Add to group - add a candidate to a group. Clicking this option will reveal the following screen for the user to enter a password for authentication from the Candidate Switch before being added to the SIM group. Click OK to enter the password or Cancel to exit the window.

Figure 6- 60. Input password window.

Property - to pop up a window to display the device information, as shown below.

76

xStack DGS-3400 Series Fast Ethernet Switch

Figure 6- 61. Device Property window.

This window holds the following information:

Parameter

Device Name

Module Name

MAC Address

Remote Port No.

Local Port No.

Description

This field will display the Device Name of the switches in the SIM group configured by the user. If no Device Name is configured by the name, it will be given the name default and tagged with the last six digits of the MAC Address to identify it.

Displays the full module name of the switch that was right-clicked.

Displays the MAC Address of the corresponding Switch.

Displays the number of the physical port on the MS or CaS that the CS is connected to. The CS will have no entry in this field.

Displays the number of the physical port on the CS that the MS or CaS is connected to. The CS will have no entry in this field.

Displays the connection speed between the CS and the MS or CaS Port Speed

Click Close to close the Property window.

Menu Bar

The Single IP Management window contains a menu bar for device configurations, as seen below.

Figure 6- 62. Menu Bar of the Topology View

The five menus on the menu bar are as follows.

77

xStack DGS-3400 Series Fast Ethernet Switch

File

Print Setup - will view the image to be printed.

Print Topology - will print the topology map.

Preference - will set display properties, such as polling interval, and the views to open at SIM startup.

Group

Add to group - add a candidate to a group. Clicking this option will reveal the following screen for the user to enter a password for authentication from the Candidate Switch before being added to the SIM group. Click OK to enter the password or Cancel to exit the window.

Figure 6- 63. Input password window.

Remove from Group - remove an MS from the group.

Device

Configure - will open the web manager for the specific device.

View

Refresh - update the views with the latest status.

Topology - display the Topology view.

Help

About - Will display the SIM information, including the current SIM version.

Single IP Management Firmware Upgrade

The Comander Switch may be used for firmware upgrades of emeber switches. To access the following window, click

Single IP Management > Firmware Upgrade. Member Switches will be listed in the table and will be specified by Port

(port on the CS where the MS resides), MAC Address, Model Name and Version. To specify a certain Switch for firmware download, click its corresponding check box under the Port heading. To update the firmware, enter the Server IP

Address where the firmware resides and enter the Path/Filename of the firmware. Click Download to initiate the file transfer.

Figure 6- 64. Single IP Management Firmware Upgrade menu

78

xStack DGS-3400 Series Fast Ethernet Switch

Single IP Management Configuration File Backup/Restore

The Commander Switch can instruct configuration file backup and restore to the Member Switch using a TFTP server.

Member Switches will be listed in the table and will be specified by Port (port on the CS where the MS resides), MAC

Address, Model Name and Version. To specify a certain Switch for upgrading configuration files, click its corresponding radio button under the Port heading. To update the configuration file, enter the Server IP Address where the file resides and enter the Path/Filename of the configuration file. Click Download to initiate the file transfer from a TFTP server to the Switch. Click Upload to backup the configuration file to a TFTP server.

Figure 6- 65. Single IP Management Configuration File Backup and Restore

Single IP Management Log Files

The Commander Switch can order a log file from a member switch sent to a server. Provide the Server IP address for storing the log and the log file path and filename on the member switch. Click Upload to send the log file to a TFTP server.

Figure 6- 66. Single IP Management Upload Log menu

79

xStack DGS-3400 Series Fast Ethernet Switch

Section 7

Layer 2 Features

VLANs

Trunking

IGMP Snooping

Spanning Tree

Forwarding and Filtering

The following section will aid the user in configuring security functions for the Switch. The Switch includes various functions for VLAN, Trunking, IGMP Snooping, Spanning Tree, and Forwarding, all discussed in detail in the following section.

VLANs

Understanding IEEE 802.1p Priority

Priority tagging is a function defined by the IEEE 802.1p standard designed to provide a means of managing traffic on a network where many different types of data may be transmitted simultaneously. It is intended to alleviate problems associated with the delivery of time critical data over congested networks. The quality of applications that are dependent on such time critical data, such as video conferencing, can be severely and adversely affected by even very small delays in transmission.

Network devices that are in compliance with the IEEE 802.1p standard have the ability to recognize the priority level of data packets. These devices can also assign a priority label or tag to packets. Compliant devices can also strip priority tags from packets. This priority tag determines the packet's degree of expeditiousness and determines the queue to which it will be assigned.

Priority tags are given values from 0 to 7 with 0 being assigned to the lowest priority data and 7 assigned to the highest.

The highest priority tag 7 is generally only used for data associated with video or audio applications, which are sensitive to even slight delays, or for data from specified end users whose data transmissions warrant special consideration.

The Switch allows you to further tailor how priority tagged data packets are handled on your network. Using queues to manage priority tagged data allows you to specify its relative priority to suit the needs of your network. There may be circumstances where it would be advantageous to group two or more differently tagged packets into the same queue.

Generally, however, it is recommended that the highest priority queue, Queue 7, be reserved for data packets with a priority value of 7. Packets that have not been given any priority value are placed in Queue 0 and thus given the lowest priority for delivery.

Strick mode and weighted round robin system are employed on the Switch to determine the rate at which the queues are emptied of packets. The ratio used for clearing the queues is 4:1. This means that the highest priority queue, Queue 7, will clear 4 packets for every 1 packet cleared from Queue 0.

Remember, the priority queue settings on the Switch are for all ports, and all devices connected to the Switch will be affected. This priority queuing system will be especially beneficial if your network employs switches with the capability of assigning priority tags.

VLAN Description

A Virtual Local Area Network (VLAN) is a network topology configured according to a logical scheme rather than the physical layout. VLANs can be used to combine any collection of LAN segments into an autonomous user group that appears as a single LAN. VLANs also logically segment the network into different broadcast domains so that packets are forwarded only between ports within the VLAN. Typically, a VLAN corresponds to a particular subnet, although not necessarily.

VLANs can enhance performance by conserving bandwidth, and improve security by limiting traffic to specific domains.

80

xStack DGS-3400 Series Fast Ethernet Switch

A VLAN is a collection of end nodes grouped by logic instead of physical location. End nodes that frequently communicate with each other are assigned to the same VLAN, regardless of where they are physically on the network.

Logically, a VLAN can be equated to a broadcast domain, because broadcast packets are forwarded to only members of the

VLAN on which the broadcast was initiated.

Notes about VLANs on the DGS-3400 Series

No matter what basis is used to uniquely identify end nodes and assign these nodes VLAN membership, packets cannot cross VLANs without a network device performing a routing function between the VLANs.

The DGS-3400 Series supports IEEE 802.1Q VLANs and Port-Based VLANs. The port untagging function can be used to remove the 802.1Q tag from packet headers to maintain compatibility with devices that are tag-unaware.

The Switch's default is to assign all ports to a single 802.1Q VLAN named "default."

The "default" VLAN has a VID = 1.

The member ports of Port-based VLANs may overlap, if desired.

IEEE 802.1Q VLANs

Some relevant terms:

Tagging - The act of putting 802.1Q VLAN information into the header of a packet.

Untagging - The act of stripping 802.1Q VLAN information out of the packet header.

Ingress port - A port on a switch where packets are flowing into the Switch and VLAN decisions must be made.

Egress port - A port on a switch where packets are flowing out of the Switch, either to another switch or to an end station, and tagging decisions must be made.

IEEE 802.1Q (tagged) VLANs are implemented on the Switch. 802.1Q VLANs require tagging, which enables them to span the entire network (assuming all switches on the network are IEEE 802.1Q-compliant).

VLANs allow a network to be segmented in order to reduce the size of broadcast domains. All packets entering a VLAN will only be forwarded to the stations (over IEEE 802.1Q enabled switches) that are members of that VLAN, and this includes broadcast, multicast and unicast packets from unknown sources.

VLANs can also provide a level of security to your network. IEEE 802.1Q VLANs will only deliver packets between stations that are members of the VLAN.

Any port can be configured as either tagging or untagging. The untagging feature of IEEE 802.1Q VLANs allows VLANs to work with legacy switches that don't recognize VLAN tags in packet headers. The tagging feature allows VLANs to span multiple 802.1Q-compliant switches through a single physical connection and allows Spanning Tree to be enabled on all ports and work normally.

The IEEE 802.1Q standard restricts the forwarding of untagged packets to the VLAN the receiving port is a member of.

The main characteristics of IEEE 802.1Q are as follows:

Assigns packets to VLANs by filtering.

Assumes the presence of a single global spanning tree.

Uses an explicit tagging scheme with one-level tagging.

802.1Q VLAN Packet Forwarding

Packet forwarding decisions are made based upon the following three types of rules:

Ingress rules - rules relevant to the classification of received frames belonging to a VLAN.

Forwarding rules between ports - decides whether to filter or forward the packet.

Egress rules - determines if the packet must be sent tagged or untagged.

81

xStack DGS-3400 Series Fast Ethernet Switch

Figure 7- 1. IEEE 802.1Q Packet Forwarding

802.1Q VLAN Tags

The figure below shows the 802.1Q VLAN tag. There are four additional octets inserted after the source MAC address.

Their presence is indicated by a value of 0x8100 in the EtherType field. When a packet's EtherType field is equal to

0x8100, the packet carries the IEEE 802.1Q/802.1p tag. The tag is contained in the following two octets and consists of 3 bits of user priority, 1 bit of Canonical Format Identifier (CFI - used for encapsulating Token Ring packets so they can be carried across Ethernet backbones), and 12 bits of VLAN ID (VID). The 3 bits of user priority are used by 802.1p. The

VID is the VLAN identifier and is used by the 802.1Q standard. Because the VID is 12 bits long, 4094 unique VLANs can be identified.

The tag is inserted into the packet header making the entire packet longer by 4 octets. All of the information originally contained in the packet is retained.

Figure 7- 2. IEEE 802.1Q Tag

82

xStack DGS-3400 Series Fast Ethernet Switch

The EtherType and VLAN ID are inserted after the MAC source address, but before the original EtherType/Length or

Logical Link Control. Because the packet is now a bit longer than it was originally, the Cyclic Redundancy Check (CRC) must be recalculated.

Figure 7- 3. Adding an IEEE 802.1Q Tag

Port VLAN ID

Packets that are tagged (are carrying the 802.1Q VID information) can be transmitted from one 802.1Q compliant network device to another with the VLAN information intact. This allows 802.1Q VLANs to span network devices (and indeed, the entire network, if all network devices are 802.1Q compliant).

Unfortunately, not all network devices are 802.1Q compliant. These devices are referred to as tag-unaware. 802.1Q devices are referred to as tag-aware.

Prior to the adoption of 802.1Q VLANs, port-based and MAC-based VLANs were in common use. These VLANs relied upon a Port VLAN ID (PVID) to forward packets. A packet received on a given port would be assigned that port's PVID and then be forwarded to the port that corresponded to the packet's destination address (found in the Switch's forwarding table). If the PVID of the port that received the packet is different from the PVID of the port that is to transmit the packet, the Switch will drop the packet.

Within the Switch, different PVIDs mean different VLANs (remember that two VLANs cannot communicate without an external router). So, VLAN identification based upon the PVIDs cannot create VLANs that extend outside a given switch

(or switch stack).

Every physical port on a switch has a PVID. 802.1Q ports are also assigned a PVID, for use within the Switch. If no

VLANs are defined on the Switch, all ports are then assigned to a default VLAN with a PVID equal to 1. Untagged packets are assigned the PVID of the port on which they were received. Forwarding decisions are based upon this PVID, in so far as VLANs are concerned. Tagged packets are forwarded according to the VID contained within the tag. Tagged packets are also assigned a PVID, but the PVID is not used to make packet-forwarding decisions, the VID is.

Tag-aware switches must keep a table to relate PVIDs within the Switch to VIDs on the network. The Switch will compare the VID of a packet to be transmitted to the VID of the port that is to transmit the packet. If the two VIDs are different, the

Switch will drop the packet. Because of the existence of the PVID for untagged packets and the VID for tagged packets, tag-aware and tag-unaware network devices can coexist on the same network.

A switch port can have only one PVID, but can have as many VIDs as the Switch has memory in its VLAN table to store them.

Because some devices on a network may be tag-unaware, a decision must be made at each port on a tag-aware device before packets are transmitted - should the packet to be transmitted have a tag or not? If the transmitting port is connected to a tag-unaware device, the packet should be untagged. If the transmitting port is connected to a tag-aware device, the packet should be tagged.

Tagging and Untagging

Every port on an 802.1Q compliant switch can be configured as tagging or untagging.

Ports with tagging enabled will put the VID number, priority and other VLAN information into the header of all packets that flow into and out of it. If a packet has previously been tagged, the port will not alter the packet, thus keeping the

83

xStack DGS-3400 Series Fast Ethernet Switch

VLAN information intact. Other 802.1Q compliant devices on the network to make packet-forwarding decisions can then use the VLAN information in the tag.

Ports with untagging enabled will strip the 802.1Q tag from all packets that flow into and out of those ports. If the packet doesn't have an 802.1Q VLAN tag, the port will not alter the packet. Thus, all packets received by and forwarded by an untagging port will have no 802.1Q VLAN information. (Remember that the PVID is only used internally within the

Switch). Untagging is used to send packets from an 802.1Q-compliant network device to a non-compliant network device.

Ingress Filtering

A port on a switch where packets are flowing into the Switch and VLAN decisions must be made is referred to as an ingress port. If ingress filtering is enabled for a port, the Switch will examine the VLAN information in the packet header

(if present) and decide whether or not to forward the packet.

If the packet is tagged with VLAN information, the ingress port will first determine if the ingress port itself is a member of the tagged VLAN. If it is not, the packet will be dropped. If the ingress port is a member of the 802.1Q VLAN, the Switch then determines if the destination port is a member of the 802.1Q VLAN. If it is not, the packet is dropped. If the destination port is a member of the 802.1Q VLAN, the packet is forwarded and the destination port transmits it to its attached network segment.

If the packet is not tagged with VLAN information, the ingress port will tag the packet with its own PVID as a VID (if the port is a tagging port). The switch then determines if the destination port is a member of the same VLAN (has the same

VID) as the ingress port. If it does not, the packet is dropped. If it has the same VID, the packet is forwarded and the destination port transmits it on its attached network segment.

This process is referred to as ingress filtering and is used to conserve bandwidth within the Switch by dropping packets that are not on the same VLAN as the ingress port at the point of reception. This eliminates the subsequent processing of packets that will just be dropped by the destination port.

Default VLANs

The Switch initially configures one VLAN, VID = 1, called "default." The factory default setting assigns all ports on the

Switch to the "default." As new VLANs are configured in Port-based mode, their respective member ports are removed from the "default."

Packets cannot cross VLANs. If a member of one VLAN wants to connect to another VLAN, the link must be through an external router.

NOTE: If no VLANs are configured on the Switch, then all packets will be forwarded to any destination port. Packets with unknown source addresses will be flooded to all ports.

Broadcast and multicast packets will also be flooded to all ports.

An example is presented below:

Table 1. VLAN Example - Assigned Ports

VLAN Name

System (default)

Engineering

Marketing

Finance

Sales

3

4

5

VID

1

2

Switch Ports

5, 6, 7, 8, 21, 22, 23, 24

9, 10, 11, 12

13, 14, 15, 16

17, 18, 19, 20

1, 2, 3, 4

84

xStack DGS-3400 Series Fast Ethernet Switch

Port-based VLANs

Port-based VLANs limit traffic that flows into and out of switch ports. Thus, all devices connected to a port are members of the VLAN(s) the port belongs to, whether there is a single computer directly connected to a switch, or an entire department.

On port-based VLANs, NICs do not need to be able to identify 802.1Q tags in packet headers. NICs send and receive normal Ethernet packets. If the packet's destination lies on the same segment, communications take place using normal

Ethernet protocols. Even though this is always the case, when the destination for a packet lies on another switch port,

VLAN considerations come into play to decide if the packet gets dropped by the Switch or delivered.

VLAN Segmentation

Take for example a packet that is transmitted by a machine on Port 1 that is a member of VLAN 2. If the destination lies on another port (found through a normal forwarding table lookup), the Switch then looks to see if the other port (Port 10) is a member of VLAN 2 (and can therefore receive VLAN 2 packets). If Port 10 is not a member of VLAN 2, then the packet will be dropped by the Switch and will not reach its destination. If Port 10 is a member of VLAN 2, the packet will go through. This selective forwarding feature based on VLAN criteria is how VLANs segment networks. The key point being that Port 1 will only transmit on VLAN 2.

Network resources such as printers and servers however, can be shared across VLANs. This is achieved by setting up overlapping VLANs. That is ports can belong to more than one VLAN group. For example, setting VLAN 1 members to ports 1, 2, 3, and 4 and VLAN 2 members to ports 1, 5, 6, and 7. Port 1 belongs to two VLAN groups. Ports 8, 9, and 10 are not configured to any VLAN group. This means ports 8, 9, and 10 are in the same VLAN group.

VLAN and Trunk Groups

The members of a trunk group have the same VLAN setting. Any VLAN setting on the members of a trunk group will apply to the other member ports.

NOTE: In order to use VLAN segmentation in conjunction with port trunk groups, you can first set the port trunk group(s), and then you may configure VLAN settings. If you wish to change the port trunk grouping with VLANs already in place, you will not need to reconfigure the VLAN settings after changing the port trunk group settings. VLAN settings will automatically change in conjunction with the change of the port trunk group settings.

Static VLAN Entry

In the Layer 2 Features folder, click VLAN > Static VLAN Entry to open the following window:

Figure 7- 4. Current 802.1Q Static VLANs Entries window

The Current 802.1Q Static VLAN Entries window lists all previously configured VLANs by VLAN ID and VLAN

Name. To delete an existing 802.1Q VLAN, click the corresponding X button under the Delete heading.

To create a new 802.1Q VLAN, click the Add button in the 802.1Q Static VLANs window. A new window will appear, as shown below, to configure the port settings and to assign a unique name and number to the new VLAN. See the table below for a description of the parameters in the new window.

85

xStack DGS-3400 Series Fast Ethernet Switch

Figure 7- 5. 802.1Q Static VLAN window - Add

To return to the Current 802.1Q Static VLANs Entries window, click the Show All Static VLAN Entries link. To change an existing 802.1Q VLAN entry, click the Modify button of the corresponding entry you wish to modify. A new menu will appear to configure the port settings and to assign a unique name and number to the new VLAN. See the table below for a description of the parameters in the new menu.

NOTE: The Switch supports up to 4k static VLAN entries.

86

xStack DGS-3400 Series Fast Ethernet Switch

Figure 7- 6. 802.1Q Static VLAN window - Modify

The following fields can then be set in either the Add or Modify 802.1Q Static VLANs windows:

Parameter

VID (VLAN ID)

VLAN Name

Advertisement

Port Settings

Tag

None

Egress

Forbidden

Description

Allows the entry of a VLAN ID in the Add window, or displays the VLAN ID of an existing VLAN in the Modify window. VLANs can be identified by either the

VID or the VLAN name.

Allows the entry of a name for the new VLAN in the Add window, or for editing the VLAN name in the Modify window.

Enabling this function will allow the Switch to send out GVRP packets to outside sources, notifying that they may join the existing VLAN.

Allows an individual port to be specified as member of a VLAN.

Specifies the port as either 802.1Q tagging or 802.1Q untagged. Checking the box will designate the port as Tagged.

Allows an individual port to be specified as a non-VLAN member.

Select this to specify the port as a static member of the VLAN. Egress member ports are ports that will be transmitting traffic for the VLAN. These ports can be either tagged or untagged.

Select this to specify the port as not being a member of the VLAN and that the port is forbidden from becoming a member of the VLAN dynamically.

Click Apply to implement changes made.

87

xStack DGS-3400 Series Fast Ethernet Switch

GVRP Setting

In the Administration menu, open the VLAN folder and click GVRP Settings. The 802.1Q Port Settings window, shown below, allows you to determine whether the Switch will share its VLAN configuration information with other

GARP VLAN Registration Protocol (GVRP) enabled switches. In addition, Ingress Checking can be used to limit traffic by filtering incoming packets whose PVID does not match the PVID of the port. Results can be seen in the table under the configuration settings, as seen below.

Figure 7- 7. 802.1Q Port Settings window

Click Apply to implement changes made. See table below for description of parameters.

88

xStack DGS-3400 Series Fast Ethernet Switch

The following fields can be set:

Parameter

From/To

PVID

GVRP

Ingress Check

Acceptable Frame Type

Description

These two fields allow you to specify the range of ports that will be included in the Port-based VLAN that you are creating using the 802.1Q Port Settings window.

The read-only field in the 802.1Q Port Table shows the current PVID assignment for each port, which may be manually assigned to a VLAN when created in the 802.1Q Port Settings table. The Switch's default is to assign all ports to the default VLAN with a VID of 1.The PVID is used by the port to tag outgoing, untagged packets, and to make filtering decisions about incoming packets. If the port is specified to accept only tagged frames - as tagging, and an untagged packet is forwarded to the port for transmission, the port will add an 802.1Q tag using the PVID to write the VID in the tag. When the packet arrives at its destination, the receiving device will use the PVID to make VLAN forwarding decisions. If the port receives a packet, and Ingress filtering is enabled, the port will compare the VID of the incoming packet to its PVID. If the two are unequal, the port will drop the packet. If the two are equal, the port will receive the packet.

The Group VLAN Registration Protocol (GVRP) enables the port to dynamically become a member of a VLAN. GVRP is Disabled by default.

This field can be toggled using the space bar between Enabled and Disabled.

Enabled enables the port to compare the VID tag of an incoming packet with the PVID number assigned to the port. If the two are different, the port filters

(drops) the packet. Disabled disables ingress filtering. Ingress Checking is

Disabled by default.

This field denotes the type of frame that will be accepted by the port. The user may choose between Tagged Only, which means only VLAN tagged frames will be accepted, and Admit_All, which mean both tagged and untagged frames will be accepted. Admit_All is enabled by default.

Click Apply to implement changes made.

89

xStack DGS-3400 Series Fast Ethernet Switch

Trunking

Understanding Port Trunk Groups

Port trunk groups are used to combine a number of ports together to make a single high-bandwidth data pipeline. DGS-

3400 Series supports up to 32 port trunk groups with 2 to 8 ports in each group. A potential bit rate of 8000 Mbps can be achieved.

Figure 7- 8. Example of Port Trunk Group

The Switch treats all ports in a trunk group as a single port. Data transmitted to a specific host (destination address) will always be transmitted over the same port in a trunk group. This allows packets in a data stream to arrive in the same order they were sent.

NOTE: If any ports within the trunk group become disconnected, packets intended for the disconnected port will be load shared among the other unlinked ports of the link aggregation group.

Link aggregation allows several ports to be grouped together and to act as a single link. This gives a bandwidth that is a multiple of a single link's bandwidth.

Link aggregation is most commonly used to link a bandwidth intensive network device or devices, such as a server, to the backbone of a network.

The Switch allows the creation of up to 32 link aggregation groups, each group consisting of 2 to 8 links (ports). The aggregated links must be contiguous (they must have sequential port numbers) except the four (optional) Gigabit ports, which can only belong to a single link aggregation group. All of the ports in the group must be members of the same

VLAN, and their STP status, static multicast, traffic control; traffic segmentation and 802.1p default priority configurations must be identical. Port locking, port mirroring and 802.1X must not be enabled on the trunk group. Further, the aggregated links must all be of the same speed and should be configured as full duplex.

The Master Port of the group is to be configured by the user, and all configuration options, including the VLAN configuration that can be applied to the Master Port, are applied to the entire link aggregation group.

90

xStack DGS-3400 Series Fast Ethernet Switch

Load balancing is automatically applied to the ports in the aggregated group, and a link failure within the group causes the network traffic to be directed to the remaining links in the group.

The Spanning Tree Protocol will treat a link aggregation group as a single link, on the switch level. On the port level, the

STP will use the port parameters of the Master Port in the calculation of port cost and in determining the state of the link aggregation group. If two redundant link aggregation groups are configured on the Switch, STP will block one entire group; in the same way STP will block a single port that has a redundant link.

Link Aggregation

To configure port trunking, click on the Link Aggregation hyperlink in the Trunking folder under Administration to bring up the following window:

Figure 7- 9. Port Link Aggregation Group table

To configure port trunk groups, click the Add button to add a new trunk group and use the Link Aggregation Group

Configuation window (see example below) to set up trunk groups. To modify a port trunk group, click the Hyperlinked

Group ID. To delete a port trunk group, click the corresponding X under the Delete heading in the Current Link Aggregation Group Entries table.

Figure 7- 10. Link Aggregation Settings – Add

91

xStack DGS-3400 Series Fast Ethernet Switch

Figure 7- 11. Link Aggregation Settings window - Modify

The user-changeable parameters are as follows:

Parameter

Group ID

State

Master Port

Member Ports

Flooding Port

Active Port

Type

Description

Select an ID number for the group, between 1 and 32.

Trunk groups can be toggled between Enabled and Disabled. This is used to turn a port trunking group on or off. This is useful for diagnostics, to quickly isolate a bandwidth intensive network device or to have an absolute backup aggregation group that is not under automatic control.

Choose the Master Port for the trunk group using the pull-down menu.

Choose the members of a trunked group. Up to eight ports per group can be assigned to a group.

A trunking group must designate one port to allow transmission of broadcasts and unknown unicasts.

Shows the port that is currently forwarding packets.

This pull-down menu allows you to select between Static and LACP (Link

Aggregation Control Protocol). LACP allows for the automatic detection of links in a Port Trunking Group.

After setting the previous parameters, click Apply to allow your changes to be implemented. Successfully created trunk groups will be show in the Current Link Aggregation Group Entries.

92

xStack DGS-3400 Series Fast Ethernet Switch

LACP Port Setting

The LACP Port Setting window is used in conjunction with the Link Aggregation window to create port trunking groups on the Switch. Using the following window, the user may set which ports will be active and passive in processing and sending LACP control frames.

Figure 7- 12. LACP Port Settings window

The user may set the following parameters:

Parameter

From/To

Mode

Description

A consecutive group of ports may be configured starting with the selected port.

Active - Active LACP ports are capable of processing and sending LACP control frames. This allows LACP compliant devices to negotiate the aggregated link so the group may be changed dynamically as needs require.

In order to utilize the ability to change an aggregated port group, that is, to add or subtract ports from the group, at least one of the participating devices must designate LACP ports as active. Both devices must support LACP.

Passive - LACP ports that are designated as passive cannot initially send

LACP control frames. In order to allow the linked port group to negotiate adjustments and make changes dynamically, one end of the connection must have "active" LACP ports (see above).

After setting the previous parameters, click Apply to allow your changes to be implemented. The LACP Port Table shows which ports are active and/or passive.

93

xStack DGS-3400 Series Fast Ethernet Switch

IGMP

Internet Group Management Protocol (IGMP) snooping allows the Switch to recognize IGMP queries and reports sent between network stations or devices and an IGMP host. When enabled for IGMP snooping, the Switch can open or close a port to a specific device based on IGMP messages passing through the Switch.

In order to use IGMP Snooping it must first be enabled for the entire Switch (see Device Information). You may then fine-tune the settings for each VLAN using the IGMP Snooping Settings link in the Administration folder. When enabled for IGMP snooping, the Switch can open or close a port to a specific multicast group member based on IGMP messages sent from the device to the IGMP host or vice versa. The Switch monitors IGMP messages and discontinues forwarding multicast packets when there are no longer hosts requesting that they continue.

IGMP Snooping

To view the IGMP Snooping Settings window, click Use the Current IGMP Snooping Group Entries window to view

IGMP Snooping settings. To modify the settings, click the Modify button of the VLAN ID you want to change.

Figure 7- 13. Current IGMP Snooping Group Entries window

Clicking the Modify button will open the IGMP Snooping Settings window, shown below:

Figure 7- 14. IGMP Snooping Settings window

94

xStack DGS-3400 Series Fast Ethernet Switch

The following parameters may be viewed or modified:

Parameter Description

VLAN ID

VLAN Name

Query Interval

Max Response Time

This is the VLAN ID that, along with the VLAN Name, identifies the VLAN the user wishes to modify the IGMP Snooping Settings for.

This is the VLAN Name that, along with the VLAN ID, identifies the VLAN the user wishes to modify the IGMP Snooping Settings for.

The Query Interval field is used to set the time (in seconds) between transmitting IGMP queries. Entries between 1 and 65535 seconds are allowed.

Default = 125.

This determines the maximum amount of time in seconds allowed before sending an IGMP response report. The Max Response Time field allows an entry between 1 and 25 (seconds). Default = 10.

Robustness Variable Adjust this variable according to expected packet loss. If packet loss on the

VLAN is expected to be high, the Robustness Variable should be increased to accommodate increased packet loss. This entry field allows an entry of 1 to

255. Default = 2.

Last Member Query Interval This field specifies the maximum amount of time between group-specific query messages, including those sent in response to leave group messages. Default

= 1.

Host Timeout This is the maximum amount of time in seconds allowed for a host to continue membership in a multicast group without the Switch receiving a host membership report. Default = 260.

Route Timeout

Leave Timer

Querier State

State

Fast Leave

This is the maximum amount of time in seconds a route is kept in the forwarding table without receiving a membership report. Default = 260.

This specifies the maximum amount of time in seconds between the Switch receiving a leave group message from a host, and the Switch issuing a group membership query. If no response to the membership query is received before the Leave Timer expires, the (multicast) forwarding entry for that host is deleted.

Choose Enabled to enable transmitting IGMP Query packets or Disabled to disable. The default is Disabled.

Select Enabled to implement IGMP Snooping. This field is Disabled by default.

The Fast Leave option may be enabled or disabled (default). This allows an interface to be pruned without sending group-specific queries.

Click Apply to implement the new settings. Click the Show All IGMP Group Entries link to return to the Current IGMP

Snooping Group Entries window.

Static Router Ports Entry

A static router port is a port that has a multicast router attached to it. Generally, this router would have a connection to a

WAN or to the Internet. Establishing a router port will allow multicast packets coming from the router to be propagated through the network, as well as allowing multicast messages (IGMP) coming from the network to be propagated to the router.

A router port has the following behavior:

• All IGMP Report packets will be forwarded to the router port.

• IGMP queries (from the router port) will be flooded to all ports.

95

xStack DGS-3400 Series Fast Ethernet Switch

All UDP multicast packets will be forwarded to the router port. Because routers do not send IGMP reports or implement

IGMP snooping, a multicast router connected to the router port of a Layer 3 switch would not be able to receive UDP data streams unless the UDP multicast packets were all forwarded to the router port.

A router port will be dynamically configured when IGMP query packets, RIPv2 multicast, DVMRP multicast or PIM-DM multicast packets are detected flowing into a port.

Open the IGMP Snooping folder and the click on the Static Router Ports Entry link to open the Current Static Router

Ports Settings page, as shown below.

Figure 7- 15. Current Static Router Ports Entries window

The Current Static Router Ports Entries window displays all of the current entries to the Switch's static router port table.

To modify an entry, click the Modify button. This will open the Static Router Ports Settings window, as shown below.

Figure 7- 16. Static Router Ports Settings window

The following parameters can be set:

Parameter

VID (VLAN ID)

VLAN Name

Member Ports

Description

This is the VLAN ID that, along with the VLAN Name, identifies the VLAN where the multicast router is attached.

This is the name of the VLAN where the multicast router is attached.

Ports on the Switch that will have a multicast router attached to them.

Click Apply to implement the new settings.

96

xStack DGS-3400 Series Fast Ethernet Switch

Spanning Tree

This Switch supports three versions of the Spanning Tree Protocol; 802.1d STP, 802.1w Rapid STP and 802.1s MSTP.

802.1d STP will be familiar to most networking professionals. However, since 802.1w RSTP and 802.1s MSTP has been recently introduced to D-Link managed Ethernet switches, a brief introduction to the technology is provided below followed by a description of how to set up 802.1d STP, 802.1w RSTP and 802.1s MSTP.

802.1s MSTP

Multiple Spanning Tree Protocol, or MSTP, is a standard defined by the IEEE community that allows multiple VLANs to be mapped to a single spanning tree instance, which will provide multiple pathways across the network. Therefore, these

MSTP configurations will balance the traffic load, preventing wide scale disruptions when a single spanning tree instance fails. This will allow for faster convergences of new topologies for the failed instance. Frames designated for these VLANs will be processed quickly and completely throughout interconnected bridges utilizing any of the three spanning tree protocols (STP, RSTP or MSTP).

This protocol will also tag BDPU packets so receiving devices can distinguish spanning tree instances, spanning tree regions and the VLANs associated with them. An MSTI ID will classify these instances. MSTP will connect multiple spanning trees with a Common and Internal Spanning Tree (CIST). The CIST will automatically determine each MSTP region, its maximum possible extent and will appear as one virtual bridge that runs a single spanning tree. Consequentially, frames assigned to different VLANs will follow different data routes within administratively established regions on the network, continuing to allow simple and full processing of frames, regardless of administrative errors in defining VLANs and their respective spanning trees.

Each switch utilizing the MSTP on a network will have a single MSTP configuration that will have the following three attributes:

1. A configuration name defined by an alphanumeric string of up to 32 characters (defined in the STP Bridge

Global Settings window in the Configuration Name field).

2. A configuration revision number (named here as a Revision Level and found in the STP Bridge Global Settings window) and;

3. A 4096-element table (defined here as a VID List in the MST Configuration Table window), which will associate each of the possible 4096 VLANs supported by the Switch for a given instance.

To utilize the MSTP function on the Switch, three steps need to be taken:

1. The Switch must be set to the MSTP setting (found in the STP Bridge Global Settings window in the STP

Version field)

2. The correct spanning tree priority for the MSTP instance must be entered (defined here as a Priority in the MST

Configuration Table window when configuring an MSTI ID settings).

3. VLANs that will be shared must be added to the MSTP Instance ID (defined here as a VID List in the MST

Configuration Table window when configuring an MSTI ID settings).

802.1w Rapid Spanning Tree

The Switch implements three versions of the Spanning Tree Protocol, the Multiple Spanning Tree Protocol (MSTP) as defined by the IEEE 802.1s, the Rapid Spanning Tree Protocol (RSTP) as defined by the IEEE 802.1w specification and a version compatible with the IEEE 802.1d STP. RSTP can operate with legacy equipment implementing IEEE 802.1d, however the advantages of using RSTP will be lost.

The IEEE 802.1w Rapid Spanning Tree Protocol (RSTP) evolved from the 802.1d STP standard. RSTP was developed in order to overcome some limitations of STP that impede the function of some recent switching innovations, in particular, certain Layer 3 functions that are increasingly handled by Ethernet switches. The basic function and much of the terminology is the same as STP. Most of the settings configured for STP are also used for RSTP. This section introduces some new Spanning Tree concepts and illustrates the main differences between the two protocols.

Port Transition States

An essential difference between the three protocols is in the way ports transition to a forwarding state and in the way this transition relates to the role of the port (forwarding or not forwarding) in the topology. MSTP and RSTP combine the transition states disabled, blocking and listening used in 802.1d and creates a single state Discarding. In either case, ports do not forward packets. In the STP port transition states disabled, blocking or listening or in the RSTP/MSTP port state

97

xStack DGS-3400 Series Fast Ethernet Switch discarding, there is no functional difference, the port is not active in the network topology. Table 6-1 below compares how the three protocols differ regarding the port state transition.

All three protocols calculate a stable topology in the same way. Every segment will have a single path to the root bridge.

All bridges listen for BPDU packets. However, BPDU packets are sent more frequently - with every Hello packet. BPDU packets are sent even if a BPDU packet was not received. Therefore, each link between bridges is sensitive to the status of the link. Ultimately this difference results in faster detection of failed links, and thus faster topology adjustment. A drawback of 802.1d is this absence of immediate feedback from adjacent bridges.

Table 2. Comparing Port States

802.1d MSTP 802.1w RSTP 802.1d STP Forwarding

Disabled Disabled Disabled No

Learning

No

Discarding Discarding Blocking No No

Discarding Discarding Listening No No

Learning Learning Learning No

Forwarding Forwarding Forwarding Yes

Yes

Yes

RSTP is capable of a more rapid transition to a forwarding state - it no longer relies on timer configurations - RSTP compliant bridges are sensitive to feedback from other RSTP compliant bridge links. Ports do not need to wait for the topology to stabilize before transitioning to a forwarding state. In order to allow this rapid transition, the protocol introduces two new variables: the edge port and the point-to-point (P2P) port.

Edge Port

The edge port is a configurable designation used for a port that is directly connected to a segment where a loop cannot be created. An example would be a port connected directly to a single workstation. Ports that are designated as edge ports transition to a forwarding state immediately without going through the listening and learning states. An edge port loses its status if it receives a BPDU packet, immediately becoming a normal spanning tree port.

P2P Port

A P2P port is also capable of rapid transition. P2P ports may be used to connect to other bridges. Under RSTP/MSTP, all ports operating in full-duplex mode are considered to be P2P ports, unless manually overridden through configuration.

802.1d/802.1w/802.1s Compatibility

MSTP or RSTP can interoperate with legacy equipment and is capable of automatically adjusting BPDU packets to 802.1d format when necessary. However, any segment using 802.1d STP will not benefit from the rapid transition and rapid topology change detection of MSTP or RSTP. The protocol also provides for a variable used for migration in the event that legacy equipment on a segment is updated to use RSTP or MSTP.

The Spanning Tree Protocol (STP) operates on two levels:

1. On the switch level, the settings are globally implemented.

2. On the port level, the settings are implemented on a per user-defined group of ports basis.

98

xStack DGS-3400 Series Fast Ethernet Switch

STP Bridge Global Settings

To open the following window, open the Spanning Tree folder in the Layer 2 Features menu and click the STP Bridge

Global Settings link. Use the STP Status pull-down selector to enable or disable STP globally, and choose the STP method used with the STP Version menu.

Figure 7- 17. STP Bridge Global Settings window – RSTP (default)

Figure 7- 18. STP Bridge Global Settings window - MSTP

99

xStack DGS-3400 Series Fast Ethernet Switch

Figure 7- 19. STP Bridge Global Settings – STP Compatible

See the table below for descriptions of the STP versions and corresponding setting options.

NOTE: The Hello Time cannot be longer than the Max. Age. Otherwise, a configuration error will occur. Observe the following formulas when setting the above parameters:

Max. Age <= 2 x (Forward Delay - 1 second)

Max. Age <= 2 x (Hello Time + 1 second)

100

xStack DGS-3400 Series Fast Ethernet Switch

Configure the following parameters for STP:

Parameter Description

STP Status

STP Version

Hello Time (1 - 10 Sec) <2>

Max Age (6 - 40 Sec) <20>

Forward Delay (4 - 30 sec)

<15 >

Max Hops (1-20) <20>

Use the pull-down menu to globally enable or disable STP.

Use the pull-down menu to choose the desired version of STP:

STP - Select this parameter to set the Spanning Tree Protocol (STP) globally on the switch.

RSTP - Select this parameter to set the Rapid Spanning Tree Protocol (RSTP) globally on the Switch.

MSTP - Select this parameter to set the Multiple Spanning Tree Protocol

(MSTP) globally on the Switch.

The Hello Time can be set from 1 to 10 seconds. This is the interval between two transmissions of BPDU packets sent by the Root Bridge to tell all other switches that it is indeed the Root Bridge. This field will only appear here when

STP or RSTP is selected for the STP Version. For MSTP, the Hello Time must be set on a port per port basis. See the MST Port Settings section for further details.

The Max Age may be set to ensure that old information does not endlessly circulate through redundant paths in the network, preventing the effective propagation of the new information. Set by the Root Bridge, this value will aid in determining that the Switch has spanning tree configuration values consistent with other devices on the bridged LAN. If the value ages out and a

BPDU has still not been received from the Root Bridge, the Switch will start sending its own BPDU to all other switches for permission to become the Root

Bridge. If it turns out that your switch has the lowest Bridge Identifier, it will become the Root Bridge. The user may choose a time between 6 and 40 seconds. The default value is 20.

The Forward Delay can be from 4 to 30 seconds. Any port on the Switch spends this time in the listening state while moving from the blocking state to the forwarding state.

Used to set the number of hops between devices in a spanning tree region before the BPDU (bridge protocol data unit) packet sent by the Switch will be discarded. Each switch on the hop count will reduce the hop count by one until the value reaches zero. The Switch will then discard the BDPU packet and the information held for the port will age out. The user may set a hop count from 1 to 20. The default is 20.

TX Hold Count (1-10) <3>

Forwarding BPDU

<Enabled>

This field can be Enabled or Disabled. When Enabled, it allows the forwarding of STP BPDU packets from other network devices. The default is Enabled.

Loopback Guard <Enabled> When enabled, the Switch will temporarily block STP switch-wide when a

BDPU packet has looped back. If the Switch detects its own BDPU packet coming back, it signifies a loop on the network – STP is automatically blocked and an alert is sent to the administrator. The default is Enabled.

LBD Auto Recover <60>

Used to set the maximum number of Hello packets transmitted per interval.

The count can be specified from 1 to 10. The default is 3.

Time allowed (in seconds) for recovery when an STP loopback is detected.

After the timer has expired the Switch checks for an STP loopback, if no loopback detected, STP is resumed. Entering 0 will disable LDB recovery.

Click Apply to implement changes made.

101

xStack DGS-3400 Series Fast Ethernet Switch

MST Configuration Identification

The following screens in the MST Configuration Identification window allow the user to configure a MSTI instance on the Switch. These settings will uniquely identify a multiple spanning tree instance set on the Switch. The Switch initially possesses one CIST or Common Internal Spanning Tree of which the user may modify the parameters for but cannot change the MSTI ID for, and cannot be deleted. To view the Current MST Configuration Identification window, click

Layer 2 Features > Spanning Tree > MST Configuration Identification:

Figure 7- 20. Current MST Configuration Identification menu

The window above contains the following information:

Parameter

Configuration Name

Revision Level

MSTI ID

Description

A previously configured name set on the Switch to uniquely identify the MSTI

(Multiple Spanning Tree Instance). If a configuration name is not set, this field will show the MAC address to the device running MSTP. This field can be set in the STP Bridge Global Settings window.

This value, along with the Configuration Name will identify the MSTP region configured on the Switch.

This field shows the MSTI IDs currently set on the Switch. This field will always have the CIST MSTI, which may be configured but not deleted. Clicking the hyperlinked name will open a new window for configuring parameters associated with that particular MSTI.

This field displays the VLAN IDs associated with the specific MSTI. VID List

Clicking the Add button will reveal the following window to configure:

102

xStack DGS-3400 Series Fast Ethernet Switch

Figure 7- 21. Instance ID Settings window – Add

The user may configure the following parameters to create a MSTI in the Switch.

Parameter

MSTI ID

Type

VID List (1-4094)

Description

Enter a number between 1 and 15 to set a new MSTI on the Switch.

Create is selected to create a new MSTI. No other choices are available for this field when creating a new MSTI.

This field is used to specify the VID range from configured VLANs set on the

Switch. Supported VIDs on the Switch range from ID number 1 to 4094.

Click Apply to implement changes made.

To configure the settings for the CIST, click on its hyperlinked name in the Current MST Configuration Identification window, which will reveal the following window to configure:

Figure 7- 22. Instance ID Settings window - CIST modify

The user may configure the following parameters to configure the CIST on the Switch.

Parameter

MSTI ID

Type

VID List (1-4094)

Description

The MSTI ID of the CIST is 0 and cannot be altered.

This field allows the user to choose a desired method for altering the MSTI settings. The user has 2 choices.

Add VID - Select this parameter to add VIDs to the MSTI ID, in conjunction with the VID List parameter.

Remove VID - Select this parameter to remove VIDs from the MSTI ID, in conjunction with the VID List parameter.

This field is used to specify the VID range from configured VLANs set on the

Switch. Supported VIDs on the Switch range from ID number 1 to 4094. This field is inoperable when configuring the CIST.

Click Apply to implement changes made.

103

xStack DGS-3400 Series Fast Ethernet Switch

To configure the parameters for a previously set MSTI, click on its hyperlinked MSTI ID number, which will reveal the following window for configuration.

Figure 7- 23. Instance ID Settings window – modify

The user may configure the following parameters for a MSTI on the Switch.

Parameter

MSTI ID

Type

VID List (1-4094)

Description

Displays the MSTI ID previously set by the user.

This field allows the user to choose a desired method for altering the MSTI settings. The user has four choices.

Add - Select this parameter to add VIDs to the MSTI ID, in conjunction with the

VID List parameter.

Remove - Select this parameter to remove VIDs from the MSTI ID, in conjunction with the VID List parameter.

This field is used to specify the VID range from configured VLANs set on the

Switch that the user wishes to add to this MSTI ID. Supported VIDs on the

Switch range from ID number 1 to 4094. This parameter can only be utilized if the Type chosen is Add or Remove.

Click Apply to implement changes made.

104

xStack DGS-3400 Series Fast Ethernet Switch

MSTP Port Information

This window displays the current MSTP Port Information and can be used to update the port configuration for an MSTI ID.

If a loop occurs, the MSTP function will use the port priority to select an interface to put into the forwarding state. Set a higher priority value for interfaces to be selected for forwarding first. In instances where the priority value is identical, the

MSTP function will implement the lowest MAC address into the forwarding state and other interfaces will be blocked.

Remember that lower priority values mean higher priorities for forwarding packets. To view the following window, click

Layer 2 Features > Spanning Tree > MSTP Port Information:

Figure 7- 24. MSTP Port Information

To view the MSTI settings for a particular port, select the Port number, located in the top left hand corner of the screen and click Apply. To modify the settings for a particular MSTI Instance, click on its hyperlinked MSTI ID, which will reveal the following window.

Figure 7- 25. MSTI Settings

Parameter

Instance ID

Internal cost (0=Auto)

Priority

Description

Displays the MSTI ID of the instance being configured. An entry of 0 in this field denotes the CIST (default MSTI).

This parameter is set to represent the relative cost of forwarding packets to specified ports when an interface is selected within a STP instance. The default setting is 0 (auto). There are two options:

0 (auto) - Selecting this parameter for the internalCost will set quickest route automatically and optimally for an interface. The default value is derived from the media speed of the interface.

value 1-200000000 - Selecting this parameter with a value in the range of 1-

200000000 will set the quickest route when a loop occurs. A lower Internal cost represents a quicker transmission.

Enter a value between 0 and 240 to set the priority for the port interface. A higher priority will designate the interface to forward packets first. A lower number denotes a higher priority.

Click Apply to implement changes made.

105

xStack DGS-3400 Series Fast Ethernet Switch

STP Instance Settings

The following window displays MSTIs currently set on the Switch. To view the following table, click Layer 2 Features >

Spanning Tree > STP Instance Settings:

The following information is displayed:

Figure 7- 26. STP Instance Table

Parameter

Instance Type

Instance Status

Instance Priority

Description

Displays the instance type(s) currently configured on the Switch. Each instance type is classified by a MSTI ID. CIST refers to the default MSTI configuration set on the Switch.

Displays the current status of the corresponding MSTI ID

Displays the priority of the corresponding MSTI ID. The lowest priority will be the root bridge.

Click Apply to implement changes made.

Click the Modify button to change the priority of the MSTI. This will open the Instance ID Settings window to configure.

Figure 7- 27. STP Instance Settings Modify

Parameter

MSTI ID

Type

Priority (0-61440)

Description

Displays the MSTI ID of the instance being Modified. An entry of 0 in this field denotes the CIST (default MSTI).

The Type field in this window will be permanently set to Set Priority Only.

Enter the new priority in the Priority field

Click Apply to implement the new priority setting.

106

xStack DGS-3400 Series Fast Ethernet Switch

STP Port Settings

STP can be set up on a port per port basis. To view the STP Port Settings window click Layer 2 Features > Spanning

Tree > STP Port Settings:

Figure 7- 28. STP Port Settings window

In addition to setting Spanning Tree parameters for use on the switch level, the Switch allows for the configuration of groups of ports, each port-group of which will have its own spanning tree, and will require some of its own configuration settings. An STP Group will use the switch-level parameters entered above, with the addition of Port Priority and Port

Cost. An STP Group spanning tree works in the same way as the switch-level spanning tree, but the root bridge concept is replaced with a root port concept. A root port is a port of the group that is elected based on port priority and port cost, to be the connection to the network for the group. Redundant links will be blocked, just as redundant links are blocked on the switch level. The STP on the switch level blocks redundant links between switches (and similar network devices). The port level STP will block redundant links within an STP Group.

It is advisable to define an STP Group to correspond to a VLAN group of ports.

107

xStack DGS-3400 Series Fast Ethernet Switch

The following STP Port Settings fields can be set:

Parameter

From/To <Port 1>

External Cost < 0 = Auto>

Hello Time

Migration <Yes>

Edge <False>

P2P <True>

Forward BPDU

State

LBD

Click Apply to implement changes made.

Description

A consecutive group of ports may be configured starting with the selected port.

This defines a metric that indicates the relative cost of forwarding packets to the specified port list. Port cost can be set automatically or as a metric value.

The default value is 0 (auto).

0 (auto) - Setting 0 for the external cost will automatically set the speed for forwarding packets to the specified port(s) in the list for optimal efficiency.

Default port cost: 100Mbps port = 200000. Gigabit port = 20000. value 1-200000000 - Define a value between 1 and 200000000 to determine the external cost. The lower the number, the greater the probability the port will be chosen to forward packets.

The time interval between transmissions of configuration messages by the designated port, to other devices on the bridged LAN. The user may choose a time between 1 and 10 seconds. The default is 2 seconds. This field is only operable when the Switch is enabled for MSTP.

When operating in RSTP mode, selecting yes forces the port that has been selected to transmit RSTP BPDUs.

Choosing the True parameter designates the port as an edge port. Edge ports cannot create loops, however an edge port can lose edge port status if a topology change creates a potential for a loop. An edge port normally should not receive BPDU packets. If a BPDU packet is received, it automatically loses edge port status. Choosing the False parameter indicates that the port does not have edge port status.

Choosing the True parameter indicates a point-to-point (P2P) shared link. P2P ports are similar to edge ports, however they are restricted in that a P2P port must operate in full duplex. Like edge ports, P2P ports transition to a forwarding state rapidly thus benefiting from RSTP. A p2p value of False indicates that the port cannot have p2p status. Auto allows the port to have p2p status whenever possible and operate as if the p2p status were true. If the port cannot maintain this status, (for example if the port is forced to half-duplex operation) the p2p status changes to operate as if the p2p value were false.

The default setting for this parameter is true.

This drop-down menu allows you to enable or disable STP for the selected group of ports. The default is Enabled.

This drop-down menu allows you to enable or disable STP for the selected group of ports. The default is Enabled.

Use the pull-down menu to enable or disable the loop-back detection function on the switch for the ports configured above.

108

xStack DGS-3400 Series Fast Ethernet Switch

Forwarding & Filtering

Unicast Forwarding

Open the Forwarding & Filtering folder in the Layer 2 Features menu and click on the Unicast Forwarding link.

Figure 7- 29. Setup Static Unicast Forwarding Table window

To add or edit an entry, define the following parameters and then click Add/Modify:

Parameter

VLAN ID (VID)

MAC Address

Port

Description

The VLAN ID number of the VLAN on which the above Unicast MAC address resides.

The MAC address to which packets will be statically forwarded. This must be a unicast MAC address.

Allows the selection of the port number on which the MAC address entered above resides.

Click Add to implement the changes made. To delete an entry in the Static Unicast Forwarding Table, click the corresponding X under the Delete heading.

Static Multicast Forwarding

The following figure and table describe how to set up Multicast Forwarding on the Switch. Open the Forwarding

Filtering folder and click on the Multicast Forwarding link to see the entry screen below:

Figure 7- 30. Static Multicast Forwarding Settings window

The Static Multicast Forwarding Settings window displays all of the entries made into the Switch's static multicast forwarding table. Click the Add button to open the Setup Static Multicast Forwarding Table window, as shown below:

109

xStack DGS-3400 Series Fast Ethernet Switch

Figure 7- 31. Setup Static Multicast Forwarding Table window

The following parameters can be set:

Parameter

VID

Multicast MAC Address

Port Settings

Description

The VLAN ID of the VLAN the corresponding MAC address belongs to.

The MAC address of the static source of multicast packets. This must be a multicast MAC address.

Allows the selection of ports that will be members of the static multicast group and ports that are either forbidden from joining dynamically, or that can join the multicast group dynamically, using GMRP. The options are:

None - No restrictions on the port dynamically joining the multicast group.

When None is chosen, the port will not be a member of the Static Multicast

Group.

Egress - The port is a static member of the multicast group.

Click Apply to implement the changes made. To delete an entry in the Static Multicast Forwarding Table, click the corresponding X under the Delete heading. Click the Show All Multicast Forwarding Entries link to return to the Static

Multicast Forwarding Settings window.

Multicast Filtering Mode

Open the Forwarding Filtering folder and click on the Multicast Filtering Mode link to see the entry screen below:

Figure 7- 32. Multicast Filtering Mode

110

Parameter

VLAN Name

Filtering Mode xStack DGS-3400 Series Fast Ethernet Switch

Description

The VLAN to which the specified filtering action applies. Select the All option to apply the action to all VLANs on the Switch.

This drop-down menu allows you to select the action the Switch will take when it receives a multicast packet that requires forwarding to a port in the specified

VLAN.

Forward All Groups – This will instruct the Switch to forward a multicast packet to all multicast groups residing within the range of ports specified above.

Forward Unregistered Groups – This will instruct the Switch to forward a multicast packet whose destination is an unregistered multicast group residing within the range of ports specified above.

Filter Unregistered Groups – This will instruct the Switch to filter any multicast packets whose destination is an unregistered multicast group residing within the range of ports specified above.

111

xStack DGS-3400 Series Fast Ethernet Switch

QoS

The xStack DGS-3400 switch series supports 802.1p priority queuing Quality of Service. The following section discusses the implementation of QoS (Quality of Service) and benefits of using 802.1p priority queuing.

The Advantages of QoS

QoS is an implementation of the IEEE 802.1p standard that allows network administrators a method of reserving bandwidth for important functions that require a large bandwidth or have a high priority, such as VoIP (voice-over Internet

Protocol), web browsing applications, file server applications or video conferencing. Not only can a larger bandwidth be created, but other less critical traffic can be limited, so excessive bandwidth can be saved. The Switch has separate hardware queues on every physical port to which packets from various applications can be mapped to, and, in turn prioritized. View the following map to see how the xStack DGS-3400 switch series implements basic 802.1P priority queuing.

Figure 7- 33. An Example of the Default QoS Mapping on the Switch

The picture above shows the default priority setting for the Switch. Class-6 has the highest priority of the seven priority classes of service on the Switch. In order to implement QoS, the user is required to instruct the Switch to examine the header of a packet to see if it has the proper identifying tag. Then the user may forward these tagged packets to designated classes of service on the Switch where they will be emptied, based on priority.

For example, lets say a user wishes to have a video conference between two remotely set computers. The administrator can add priority tags to the video packets being sent out, utilizing the Access Profile commands. Then, on the receiving end, the administrator instructs the Switch to examine packets for this tag, acquires the tagged packets and maps them to a class queue on the Switch. Then in turn, the administrator will set a priority for this queue so that will be emptied before any other packet is forwarded. This results in the end user receiving all packets sent as quickly as possible, thus prioritizing the queue and allowing for an uninterrupted stream of packets, which optimizes the use of bandwidth available for the video conference.

112

xStack DGS-3400 Series Fast Ethernet Switch

Understanding QoS

The DGS-3400 Series supports 802.1p priority queuing. The Switch has 8 priority queues. These priority queues are numbered from 7 (Class 6) — the highest priority queue — to 0 (Class 0) — the lowest priority queue. The eight priority tags specified in IEEE 802.1p (p0 to p7) are mapped to the Switch’s priority queues as follows:

• Priority 0 is assigned to the Switch’s Q2 queue.

• Priority 1 is assigned to the Switch’s Q0 queue.

• Priority 2 is assigned to the Switch’s Q1 queue.

• Priority 3 is assigned to the Switch’s Q3 queue.

• Priority 4 is assigned to the Switch’s Q4 queue.

• Priority 5 is assigned to the Switch’s Q5 queue.

• Priority 6 is assigned to the Switch’s Q6 queue.

• Priority 7 is assigned to the Switch’s Q7 queue.

For strict priority-based scheduling, any packets residing in the higher priority classes of service are transmitted first.

Multiple strict priority classes of service are emptied based on their priority tags. Only when these classes are empty, are packets of lower priority transmitted.

For weighted round-robin queuing, the number of packets sent from each priority queue depends upon the assigned weight.

For a configuration of 8 CoS queues, A~H with their respective weight value: 8~1, the packets are sent in the following sequence: A1, B1, C1, D1, E1, F1, G1, H1, A2, B2, C2, D2, E2, F2, G2, A3, B3, C3, D3, E3, F3, A4, B4, C4, D4, E4, A5,

B5, C5, D5, A6, B6, C6, A7, B7, A8, A1, B1, C1, D1, E1, F1, G1, H1.

For weighted round-robin queuing, if each CoS queue has the same weight value, then each CoS queue has an equal opportunity to send packets just like round-robin queuing.

For weighted round-robin queuing, if the weight for a CoS is set to 0, then it will continue processing the packets from this

CoS until there are no more packets for this CoS. The other CoS queues that have been given a nonzero value, and depending upon the weight, will follow a common weighted round-robin scheme.

Remember that the xStack DGS-3400 switch series has 7 configurable priority queues (and seven Classes of Service) for each port on the Switch.

NOTICE: The Switch contains eight classes of service for each port on the Switch. One of these classes is reserved for internal use on the Switch and is therefore not configurable. All references in the following section regarding classes of service will refer to only the seven classes of service that may be used and configured by the administrator.

113

xStack DGS-3400 Series Fast Ethernet Switch

Bandwidth Control

The bandwidth control settings are used to place a ceiling on the transmitting and receiving data rates for any selected port.

In the QoS folder, click Bandwidth Control, to view the screen shown below.

Figure 7- 34. Bandwidth Settings and Port Bandwidth Table window

The following parameters can be set or are displayed:

Parameter

From/To

Type

No Limit

Rate

Description

A consecutive group of ports may be configured starting with the selected port.

This drop-down menu allows a selection between RX (receive,) TX (transmit,) and Both. This setting will determine whether the bandwidth ceiling is applied to receiving, transmitting, or both receiving and transmitting packets.

This drop-down menu allows the user to specify that the selected port will have no bandwidth limit. Enabled disables the limit.

This field allows the input of the data rate, in Mbit/s, that will be the limit for the selected port. The user may choose a rate between 1 and 9999 Mbit/s.

Click Apply to set the bandwidth control for the selected ports. Results of configured Bandwidth Settings will be displayed in the Port Bandwidth Table.

114

xStack DGS-3400 Series Fast Ethernet Switch

QoS Scheduling Mechanism

This drop-down menu allows a selection between a Weight Fair and a Strict mechanism for emptying the priority classes.

In the Configuration menu open the QoS folder and click QoS Scheduling Mechanism, to view the screen shown below.

Figure 7- 35. QoS Scheduling Mechanism menu and table

The Scheduling Mechanism has the following parameters.

Parameter

Strict

Weight fair

Description

The highest class of service is the first to process traffic. That is, the highest class of service will finish before other queues empty.

Use the weighted round-robin (WRR) algorithm to handle packets in an even distribution in priority classes of service.

Click Apply to let your changes take effect.

115

xStack DGS-3400 Series Fast Ethernet Switch

QoS Output Scheduling

QoS can be customized by changing the output scheduling used for the hardware classes of service in the Switch. As with any changes to QoS implementation, careful consideration should be given to how network traffic in lower priority classes of service is affected. Changes in scheduling may result in unacceptable levels of packet loss or significant transmission delay. If choosing to customize this setting, it is important to monitor network performance, especially during peak demand, as bottlenecks can quickly develop if the QoS settings are not suitable. In the Configuration folder open the QoS folder and click QoS Output Scheduling , to view the screen shown below.

Figure 7- 36. QoS Output Scheduling Configuration window

The following values may be assigned to the QoS classes to set the scheduling.

Parameter

Max. Packets

Description

Specifies the maximum number of packets the above specified hardware priority class of service will be allowed to transmit before allowing the next lowest priority queue to transmit its packets. A value between 0 and 15 can be specified.

Click Apply to implement changes made.

NOTE: Entering a 0 for the Max Packets field in the QoS Output Scheduling Configuration window above will create a Combination Queue. For more information on implementation of this feature, see the next section, Configuring the Combination Queue.

116

xStack DGS-3400 Series Fast Ethernet Switch

Configuring the Combination Queue

Utilizing the QoS Output Scheduling Configuration window shown above, the xStack DGS-3400 series can implement a combination queue for forwarding packets. This combination queue allows for a combination of strict and weight-fair

(weighted round-robin WRR) scheduling for emptying given classes of service. To set the combination queue, enter a 0 for the Max Packets entry of the corresponding priority classes of service listed in the window above. Priority classes of service that have a 0 in the Max Packet field will forward packets with strict priority scheduling. The remaining classes of service, that do not have a 0 in their Max Packet field, will follow a weighted round-robin (WRR) method of forwarding packets — as long as the priority classes of service with a 0 in their Max Packet field are empty. When a packet arrives in a priority class with a 0 in its Max Packet field, this class of service will automatically begin forwarding packets until it is empty. Once a priority class of service with a 0 in its Max Packet field is empty, the remaining priority classes of service will reset the weighted round-robin (WRR) cycle of forwarding packets, starting with the highest available priority class of service. Priority classes of service with an equal level of priority and equal entries in their Max Packet field will empty their fields based on hardware priority scheduling. The Max Packet parameter allows the maximum number of packets a given priority class of service can transmit per weighted round-robin (WRR) scheduling cycle to be selected. This provides for a controllable CoS behavior while allowing other classes to empty as well. A value between 0 and 15 packets can be specified per priority class of service to create the combination queue.

The example window below displays an example of the combination queue where Class-1 will have a strict priority for emptying its class, while the other classes will follow a weight fair scheduling.

Figure 7- 37. QoS Output Scheduling window – Combination queue example

117

xStack DGS-3400 Series Fast Ethernet Switch

802.1p Default Priority

The Switch allows the assignment of a default 802.1p priority to each port on the Switch. In the Configuration folder open the QoS folder and click 802.1p Default Priority, to view the screen shown below.

Figure 7- 38. 802.1p Default Priority window

This page allows the user to assign a default 802.1p priority to any given port on the Switch. The priority tags are numbered from 0, the lowest priority, to 7, the highest priority. To implement a new default priority, choose a port range by using the From and To pull-down menus and then insert a priority value, from 0-7 in the Priority field. Click Apply to implement settings made.

118

xStack DGS-3400 Series Fast Ethernet Switch

802.1p User Priority

The xStack DGS-3400 switch series allows the assignment of a class of service to each of the 802.1p priorities. In the

Configuration folder open the QoS folder and click 802.1p User Priority, to view the screen shown below.

Figure 7- 39. 802.1p User Priority window

Once a priority has been assigned to the port groups on the Switch, then a Class may be assigned to each of the eight levels of 802.1p priorities. Click Apply to set changes made.

119

xStack DGS-3400 Series Fast Ethernet Switch

Access Profile Table

Configuring the Access Profile Table

Access profiles allow you to establish criteria to determine whether the Switch will forward packets based on the information contained in each packet's header. These criteria can be specified on a basis of VLAN, MAC address or IP address.

Creating an access profile is divided into two basic parts. The first is to specify which part or parts of a frame the Switch will examine, such as the MAC source address or the IP destination address. The second part is entering the criteria the

Switch will use to determine what to do with the frame. The entire process is described below in two parts.

To display the currently configured Access Profiles on the Switch, open the Configuration folder and click on the Access

Profile Table link. This will open the Access Profile Table page, as shown below.

Figure 7- 40. Access Profile Table

To add an entry to the Access Profile Table, click the Add button. This will open the Access Profile Configuration page, as shown below. There are four Access Profile Configuration pages; one for Ethernet (or MAC address-based) profile configuration, one for IP address-based profile configuration, one for the Packet Content Mask and one for IPv6. You can switch between the three Access Profile Configuration pages by using the Type drop-down menu. The page shown below is the Ethernet Access Profile Configuration page.

Figure 7- 41. Access Profile Configuration (Ethernet)

120

xStack DGS-3400 Series Fast Ethernet Switch

The following parameters can be set, for the Ethernet type:

Parameter

Profile ID (1-6)

Type

VLAN

Source MAC

Destination MAC

802.1p

Ethernet type

Description

Type in a unique identifier number for this profile set. This value can be set from 1 - 6.

Select profile based on Ethernet (MAC Address), IP or IPv6 address. This will change the menu according to the requirements for the type of profile.

Select Ethernet to instruct the Switch to examine the layer 2 part of each packet header.

Select IP to instruct the Switch to examine the IP address in each frame's header.

Select IPv6 to instruct the Switch to examine the IPv6 address in each frame's header.

Selecting this option instructs the Switch to examine the VLAN identifier of each packet header and use this as the full or partial criterion for forwarding.

Source MAC Mask - Enter a MAC address mask for the source MAC address.

Destination MAC Mask - Enter a MAC address mask for the destination MAC address.

Selecting this option instructs the Switch to examine the 802.1p priority value of each packet header and use this as the, or part of the criterion for forwarding.

Selecting this option instructs the Switch to examine the Ethernet type value in each frame's header.

The page shown below is the IP Access Profile Configuration page.

Figure 7- 42. Access Profile Configuration (IP)

121

xStack DGS-3400 Series Fast Ethernet Switch

The following parameters can be set, for IP:

Parameter

Profile ID (1-6)

Type

Source IP Mask

Destination IP Mask

DSCP

Protocol

Description

Type in a unique identifier number for this profile set. This value can be set from 1 -6.

Select profile based on Ethernet (MAC Address), IP or IPv6 address. This will change the menu according to the requirements for the type of profile.

Select Ethernet to instruct the Switch to examine the layer 2 part of each packet header.

Select IP to instruct the Switch to examine the IP address in each frame's header.

Select IPv6 to instruct the Switch to examine the IPv6 address in each frame's header.

Enter an IP address mask for the source IP address.

Enter an IP address mask for the destination IP address.

Selecting this option instructs the Switch to examine the DiffServ Code part of each packet header and use this as the, or part of the criterion for forwarding.

Selecting this option instructs the Switch to examine the protocol type value in each frame's header. You must then specify what protocol(s) to include according to the following guidelines:

Select ICMP to instruct the Switch to examine the Internet Control Message

Protocol (ICMP) field in each frame's header.

Select Type to further specify that the access profile will apply an ICMP type value, or specify Code to further specify that the access profile will apply an

ICMP code value.

Select IGMP to instruct the Switch to examine the Internet Group Management

Protocol (IGMP) field in each frame's header.

Select Type to further specify that the access profile will apply an IGMP type value

Select TCP to use the TCP port number contained in an incoming packet as the forwarding criterion. Selecting TCP requires that you specify a source port mask and/or a destination port mask. The user may also identify which flag bits to filter. Flag bits are parts of a packet that determine what to do with the packet. The user may filter packets by filtering certain flag bits within the packets, by checking the boxes corresponding to the flag bits of the TCP field.

The user may choose between urg (urgent), ack (acknowledgement), psh

(push), rst (reset), syn (synchronize), fin (finish). src port mask - Specify a TCP port mask for the source port in hex form (hex

0x0-0xffff), which you wish to filter. dest port mask - Specify a TCP port mask for the destination port in hex form

(hex 0x0-0xffff) which you wish to filter.

Select UDP to use the UDP port number contained in an incoming packet as the forwarding criterion. Selecting UDP requires that you specify a source port mask and/or a destination port mask. src port mask - Specify a TCP port mask for the source port in hex form (hex

0x0-0xffff). dest port mask - Specify a TCP port mask for the destination port in hex form

(hex 0x0-0xffff). protocol id - Enter a value defining the protocol ID in the packet header to mask. Specify the protocol ID mask in hex form (hex 0x0-0xffffffff).

122

xStack DGS-3400 Series Fast Ethernet Switch

The page shown below is the IPv6 configuration window.

Figure 7- 43. Access Profile Configuration window (IPv6)

The following parameters can be set, for IP:

Parameter

Profile ID (1-6)

Type

Class

Flowlabel

Source IPv6 Mask

Destination IPv6 Mask

Click Apply to implement changes made.

Description

Type in a unique identifier number for this profile set. This value can be set from 1 - 6.

Select profile based on Ethernet (MAC Address), IP or IPv6 address. This will change the menu according to the requirements for the type of profile.

Select Ethernet to instruct the Switch to examine the layer 2 part of each packet header.

Select IP to instruct the Switch to examine the IP address in each frame's header.

Select IPv6 to instruct the Switch to examine the IPv6 address in each frame's header.

Checking this field will instruct the Switch to examine the class field of the IPv6 header. This class field is a part of the packet header that is similar to the Type of Service (ToS) or Precedence bits field in IPv4.

Checking this field will instruct the Switch to examine the flow label field of the

IPv6 header. This flow label field is used by a source to label sequences of packets such as non-default quality of service or real time service packets.

The user may specify an IP address mask for the source IPv6 address by checking the corresponding box and entering the IP address mask.

The user may specify an IP address mask for the destination IPv6 address by checking the corresponding box and entering the IP address mask.

123

xStack DGS-3400 Series Fast Ethernet Switch

To establish the rule for a previously created Access Profile:

In the Configuration folder, click the Access Profile Table link opening the Access Profile Table. Under the heading

Access Rule, clicking Modify, will open the following window.

Figure 7- 44. Access Rule Table window – IP

To create a new rule set for an access profile click the Add button. A new window is displayed. To remove a previously created rule, click the corresponding button.

Figure 7- 45. Access Rule Configuration window (IP)

124

xStack DGS-3400 Series Fast Ethernet Switch

Configure the following Access Rule Configuration settings for IP:

Parameter

Profile ID

Mode

Access ID

Type

Priority (0-7)

Replace Dscp (0-63)

Source IP

Destination IP

Dscp (0-63)

Protocol

Port

Rx rate

Description

This is the identifier number for this profile set.

Select Permit to specify that the packets that match the access profile are forwarded by the Switch, according to any additional rule added (see below).

Select Deny to specify that packets that do not match the access profile are not forwarded by the Switch and will be filtered.

Type in a unique identifier number for this access. This value can be set from 1

- 128.

Selected profile based on Ethernet (MAC Address), IP address or IPv6 address

Ethernet instructs the Switch to examine the layer 2 part of each packet header.

IP instructs the Switch to examine the IP address in each frame's header.

IPv6 instructs the Switch to examine the IPv6 address in each frame's header.

This parameter is specified if you want to re-write the 802.1p default priority previously set in the Switch, which is used to determine the CoS queue to which packets are forwarded to. Once this field is specified, packets accepted by the Switch that match this priority are forwarded to the CoS queue specified previously by the user.

Replace priority with − Click the corresponding box if you want to re-write the

802.1p default priority of a packet to the value entered in the Priority field, which meets the criteria specified previously in this command, before forwarding it on to the specified CoS queue. Otherwise, a packet will have its incoming 802.1p user priority re-written to its original value before being forwarded by the Switch.

For more information on priority queues, CoS queues and mapping for 802.1p, see the QoS section of this manual.

Select this option to instruct the Switch to replace the DSCP value (in a packet that meets the selected criteria) with the value entered in the adjacent field.

Source IP Address - Enter an IP Address mask for the source IP address.

Destination IP Address- Enter an IP Address mask for the destination IP address.

This field allows the user to enter a DSCP value in the space provided, which will instruct the Switch to examine the DiffServ Code part of each packet header and use this as the, or part of the criterion for forwarding. The user may choose a value between 0 and 63.

This field allows the user to modify the protocol used to configure the Access

Rule Table; depending on which protocol the user has chosen in the Access

Profile Table.

The Access Rule may be configured on a per-port basis by entering the port number of the switch.

A limit may be set on the incoming rate for the access rule.

125

xStack DGS-3400 Series Fast Ethernet Switch

To view the settings of a previously correctly configured rule, click in the Access Rule Table to view the following screen:

Figure 7- 46. Access Rule Display window (IP)

To configure the Access Rule for Ethernet, open the Access Profile Table and click Modify for an Ethernet entry. This will open the following screen:

Figure 7- 47. Access Rule Table

To remove a previously created rule, select it and click the button. To add a new Access Rule, click the Add button:

126

xStack DGS-3400 Series Fast Ethernet Switch

Figure 7- 48. Access Rule Configuration window - Ethernet

127

xStack DGS-3400 Series Fast Ethernet Switch

To set the Access Rule for Ethernet, adjust the following parameters and click Apply.

Parameter

Profile ID

Mode

Access ID

Type

Priority (0-7)

VLAN Name

Source MAC

Destination MAC

802.1p (0-7)

Ethernet Type

Port

Rx rate

Description

This is the identifier number for this profile set.

Select Permit to specify that the packets that match the access profile are forwarded by the Switch, according to any additional rule added (see below).

Select Deny to specify that packets that do not match the access profile are not forwarded by the Switch and will be filtered.

Type in a unique identifier number for this access. This value can be set from 1 -

128.

Selected profile based on Ethernet (MAC Address), IP address or IPv6 address

Ethernet instructs the Switch to examine the layer 2 part of each packet header.

IP instructs the Switch to examine the IP address in each frame's header.

IPv6 instructs the Switch to examine the IPv6 address in each frame's header.

This parameter is specified if you want to re-write the 802.1p default priority previously set in the Switch, which is used to determine the CoS queue to which packets are forwarded to. Once this field is specified, packets accepted by the

Switch that match this priority are forwarded to the CoS queue specified previously by the user. replace priority − Click the corresponding box if you want to re-write the 802.1p default priority of a packet to the value entered in the Priority field, which meets the criteria specified previously in this command, before forwarding it on to the specified CoS queue. Otherwise, a packet will have its incoming 802.1p user priority re-written to its original value before being forwarded by the Switch.

For more information on priority queues, CoS queues and mapping for 802.1p, see the QoS section of this manual.

Allows the entry of a name for a previously configured VLAN.

Source MAC Address - Enter a MAC Address for the source MAC address.

Destination MAC Address - Enter a MAC Address mask for the destination MAC address.

Enter a value from 0-7 to specify that the access profile will apply only to packets with this 802.1p priority value.

Specifies that the access profile will apply only to packets with this hexadecimal

802.1Q Ethernet type value (hex 0x0-0xffff) in the packet header. The Ethernet type value may be set in the form: hex 0x0-0xffff, which means the user may choose any combination of letters and numbers ranging from a-f and from 0-9999.

The Access Rule may be configured on a per-port basis by entering the port number of the switch.

A limit may be set on the incoming rate for the access rule.

128

xStack DGS-3400 Series Fast Ethernet Switch

To view the settings of a previously correctly configured rule, click screen:

in the Access Rule Table to view the following

Figure 7- 49. Access Rule Display window (Ethernet)

To configure the Access Rule for IPv6, open the Access Profile Table and click Modify for an IPv6 entry. This will open the following screen:

Figure 7- 50. Access Rule Table

Click Add to open the next screen to configure the IPv6 entry for an access rule.

Figure 7- 51. Access Rule Configuration – IPv6

129

xStack DGS-3400 Series Fast Ethernet Switch

To set the Access Rule for the Packet Content Mask, adjust the following parameters and click Apply.

Parameter Description

Profile ID

Mode

Access ID

Type

Priority

This is the identifier number for this profile set.

Select Permit to specify that the packets that match the access profile are forwarded by the Switch, according to any additional rule added (see below).

Select Deny to specify that packets that match the access profile are not forwarded by the Switch and will be filtered.

Type in a unique identifier number for this access rule. This value can be set from 1

- 128.

Selected profile based on Ethernet (MAC Address), IP address or IPv6 address

Ethernet instructs the Switch to examine the layer 2 part of each packet header.

IP instructs the Switch to examine the IP address in each frame's header.

IPv6 instructs the Switch to examine the IPv6 address in each frame's header.

This parameter is specified to re-write the 802.1p default priority previously set in the Switch, which is used to determine the CoS queue to which packets are forwarded to. Once this field is specified, packets accepted by the Switch that match this priority are forwarded to the CoS queue specified previously by the user.

Replace priority with − Click the corresponding box to re-write the 802.1p default priority of a packet to the value entered in the Priority field, which meets the criteria specified previously in this command, before forwarding it on to the specified CoS queue. Otherwise, a packet will have its incoming 802.1p user priority re-written to its original value before being forwarded by the Switch.

For more information on priority queues, CoS queues and mapping for 802.1p, see the QoS section of this manual.

Class

Flowlabel

Source IPv6 Address

Entering a value between 0 and 255 will instruct the Switch to examine the class field of the IPv6 header. This class field is a part of the packet header that is similar to the Type of Service (ToS) or Precedence bits field of IPv4.

Configuring this field, in hex form, will instruct the Switch to examine the flow label field of the IPv6 header. This flow label field is used by a source to label sequences of packets such as non-default quality of service or real time service packets.

The user may specify an IP address mask for the source IPv6 address by entering the IP address mask, in hex form.

Destination IPv6 Address The user may specify an IP address mask for the destination IPv6 address by and entering the IP address mask, in hex form.

Port

Rx rate

The Access Rule may be configured on a per-port basis by entering the port number of the switch.

A limit may be set on the incoming rate for the access rule.

130

xStack DGS-3400 Series Fast Ethernet Switch

To view the settings of a previously correctly configured rule, click screen:

in the Access Rule Table to view the following

Figure 7- 52. Access Rule Display (IPv6)

CPU Interface Filtering

Due to a chipset limitation and needed extra switch security, the xStack DGS-3400 Series switch incorporates CPU

Interface filtering. This added feature increases the running security of the Switch by enabling the user to create a list of access rules for packets destined for the Switch’s CPU interface. Employed similarly to the Access Profile feature previously mentioned, CPU interface filtering examines Ethernet, IP and Packet Content Mask packet headers destined for the CPU and will either forward them or filter them, based on the user’s implementation. As an added feature for the CPU

Filtering, the xStack DGS-3400 Series switch allows the CPU filtering mechanism to be enabled or disabled globally, permitting the user to create various lists of rules without immediately enabling them.

Creating an access profile for the CPU is divided into two basic parts. The first is to specify which part or parts of a frame the Switch will examine, such as the MAC source address or the IP destination address. The second part is entering the criteria the Switch will use to determine what to do with the frame. The entire process is described below.

CPU Interface Filtering State Settings

In the following window, the user may globally enable or disable the CPU Interface Filtering mechanism by using the pulldown menu to change the running state. To access this window, click Configuration > CPU Interface Filtering > CPU

Interface Filtering State. Choose Enabled to enable CPU packets to be scrutinized by the Switch and Disabled to disallow this scrutiny.

Figure 7- 53. CPU Interface Filtering State Settings window

131

xStack DGS-3400 Series Fast Ethernet Switch

CPU Interface Filtering Table

The CPU Interface Filtering Table displays the CPU Access Profile Table entries created on the Switch. To view the configurations for an entry, click the hyperlinked Profile ID number.

Figure 7- 54. CPU Interface Filtering Table

To add an entry to the CPU Interface Filtering Table, click the Add button. This will open the CPU Interface Filtering

Configuration page, as shown below. There are three Access Profile Configuration pages; one for Ethernet (or MAC address-based) profile configuration, one for IP address-based profile configuration and one for the Packet Content

Mask. You can switch between the three Access Profile Configuration pages by using the Type drop-down menu. The page shown below is the Ethernet CPU Interface Filtering Configuration page.

Figure 7- 55. CPU Interface Filtering Configuration window – Ethernet

132

xStack DGS-3400 Series Fast Ethernet Switch

Parameter

Profile ID (1-5)

Type

VLAN

Source MAC

Destination MAC

Ethernet type

Description

Type in a unique identifier number for this profile set. This value can be set from

1 - 5.

Select profile based on Ethernet (MAC Address), IP address or packet content mask. This will change the menu according to the requirements for the type of profile.

Select Ethernet to instruct the Switch to examine the layer 2 part of each packet header.

Select IP to instruct the Switch to examine the IP address in each frame's header.

Select Packet Content Mask to specify a mask to hide the content of the packet header.

Selecting this option instructs the Switch to examine the VLAN identifier of each packet header and use this as the full or partial criterion for forwarding.

Source MAC Mask - Enter a MAC address mask for the source MAC address.

Destination MAC Mask - Enter a MAC address mask for the destination MAC address.

Selecting this option instructs the Switch to examine the Ethernet type value in each frame's header.

Click Apply to set this entry in the Switch’s memory.

The page shown below is the IP Access Profile Configuration page.

Figure 7- 56. CPU Interface Filtering Configuration window- IP

133

xStack DGS-3400 Series Fast Ethernet Switch

Parameter

Profile ID (1-5)

Type

VLAN

Source IP Mask

Destination IP Mask

DSCP

Protocol

Description

Type in a unique identifier number for this profile set. This value can be set from 1 -

5.

Select profile based on Ethernet (MAC Address), IP address or Packet Content

Mask. This will change the menu according to the requirements for the type of profile.

Select Ethernet to instruct the Switch to examine the layer 2 part of each packet header.

Select IP to instruct the Switch to examine the IP address in each frame's header.

Select Packet Content Mask to specify a mask to hide the content of the packet header.

Selecting this option instructs the Switch to examine the VLAN part of each packet header and use this as the, or part of the criterion for forwarding.

Enter an IP address mask for the source IP address.

Enter an IP address mask for the destination IP address.

Selecting this option instructs the Switch to examine the DiffServ Code part of each packet header and use this as the, or part of the criterion for forwarding.

Selecting this option instructs the Switch to examine the protocol type value in each frame's header. You must then specify what protocol(s) to include according to the following guidelines:

Select ICMP to instruct the Switch to examine the Internet Control Message

Protocol (ICMP) field in each frame's header.

Select Type to further specify that the access profile will apply an ICMP type value, or specify Code to further specify that the access profile will apply an ICMP code value.

Select IGMP to instruct the Switch to examine the Internet Group Management

Protocol (IGMP) field in each frame's header.

Select Type to further specify that the access profile will apply an IGMP type value

Select TCP to use the TCP port number contained in an incoming packet as the forwarding criterion. Selecting TCP requires that you specify a source port mask and/or a destination port mask. The user may also identify which flag bits to filter.

Flag bits are parts of a packet that determine what to do with the packet. The user may filter packets by filtering certain flag bits within the packets, by checking the boxes corresponding to the flag bits of the TCP field. The user may choose between urg (urgent), ack (acknowledgement), psh (push), rst (reset), syn

(synchronize), fin (finish). src port mask - Specify a TCP port mask for the source port in hex form (hex 0x0-

0xffff), which you wish to filter. dest port mask - Specify a TCP port mask for the destination port in hex form (hex

0x0-0xffff) which you wish to filter.

Select UDP to use the UDP port number contained in an incoming packet as the forwarding criterion. Selecting UDP requires that you specify a source port mask and/or a destination port mask. src port mask - Specify a TCP port mask for the source port in hex form (hex 0x0-

0xffff). dest port mask - Specify a TCP port mask for the destination port in hex form (hex

0x0-0xffff). protocol id - Enter a value defining the protocol ID in the packet header to mask.

Specify the protocol ID mask in hex form (hex 0x0-0xffffffff).

Click Apply to set this entry in the Switch’s memory.

134

xStack DGS-3400 Series Fast Ethernet Switch

The page shown below is the Packet Content Mask configuration window.

Figure 7- 57. CPU Interface Filtering Configuration window- Packet Content

This screen will aid the user in configuring the Switch to mask packet headers beginning with the offset value specified.

The following fields are used to configure the Packet Content Mask:

Parameter

Profile ID (1-5)

Type

Offset

Description

Type in a unique identifier number for this profile set. This value can be set from 1

- 5.

Select profile based on Ethernet (MAC Address), IP address or packet content mask. This will change the menu according to the requirements for the type of profile.

Select Ethernet to instruct the Switch to examine the layer 2 part of each packet header.

Select IP to instruct the Switch to examine the IP address in each frame's header.

Select Packet Content Mask to specify a mask to hide the content of the packet header.

This field will instruct the Switch to mask the packet header beginning with the offset value specified:

value (0-15) - Enter a value in hex form to mask the packet from the beginning of the packet to the 15th byte.

value (16-31) – Enter a value in hex form to mask the packet from byte 16 to byte

31.

value (32-47) – Enter a value in hex form to mask the packet from byte 32 to byte

47.

value (48-63) – Enter a value in hex form to mask the packet from byte 48 to byte

63.

value (64-79) – Enter a value in hex form to mask the packet from byte 64 to byte

79.

Click Apply to implement changes made.

135

xStack DGS-3400 Series Fast Ethernet Switch

To establish the rule for a previously created CPU Access Profile:

In the Configuration folder, click the CPU Interface Filtering > CPU Interface Filtering State to open the CPU

Interface Filtering Table.

Figure 7- 58. CPU Interface Filtering Table

In this window, the user may add a rule to a previously created CPU access profile by clicking the corresponding Modify button of the entry to configure, Ethernet, IP or Packet Content. Each entry will open a new and unique window, as shown in the examples below.

Figure 7- 59. CPU Interface Filtering Table – Ethernet

To create a new rule set for an access profile click the Add button. A new window is displayed. To remove a previously created rule, click the corresponding button. The following window is used for the Ethernet Rule configuration.

136

xStack DGS-3400 Series Fast Ethernet Switch

Figure 7- 60. CPU Interface Filtering Rule Configuration – Ethernet

To set the Access Rule for Ethernet, adjust the following parameters and click Apply.

Parameter

Profile ID

Mode

Access ID

Type

VLAN Name

Source MAC

Destination MAC

802.1p (0-7)

Ethernet Type

Port

Description

This is the identifier number for this profile set.

Select Permit to specify that the packets that match the access profile are forwarded by the Switch, according to any additional rule added (see below).

Select Deny to specify that packets that do not match the access profile are not forwarded by the Switch and will be filtered.

Type in a unique identifier number for this access and priority. This value can be set from 1 - 100.

Selected profile based on Ethernet (MAC Address), IP address or Packet Content.

Ethernet instructs the Switch to examine the layer 2 part of each packet header.

IP instructs the Switch to examine the IP address in each frame's header.

Packet Content Mask instructs the Switch to examine the packet header.

Allows the entry of a name for a previously configured VLAN.

Source MAC Address - Enter a MAC Address for the source MAC address.

Destination MAC Address - Enter a MAC Address mask for the destination MAC address.

Specify the rule be based on 802.1p priority.

Specifies that the access profile will apply only to packets with this hexadecimal

802.1Q Ethernet type value (hex 0x0-0xffff) in the packet header. The Ethernet type value may be set in the form: hex 0x0-0xffff, which means the user may choose any combination of letters and numbers ranging from a-f and from 0-9999.

The rule may be configured on a per-port basis by entering the port number of the switch.

137

xStack DGS-3400 Series Fast Ethernet Switch

To view the settings of a previously correctly configured rule, click screen:

in the Access Rule Table to view the following

Figure 7- 61. CPU Interface Filtering Rule Display – Ethernet

The following window is the CPU Interface Filtering Rule Table for IP.

Figure 7- 62. CPU Interface Filtering Rule Table – IP

To create a new rule set for an access profile click the Add button. A new window is displayed. To remove a previously created rule, click the corresponding button. The following window is used for the IP Rule configuration.

Figure 7- 63. CPU Interface Filtering Rule Configuration – IP

138

xStack DGS-3400 Series Fast Ethernet Switch

Configure the following Access Rule Configuration settings for IP:

Parameter

Profile ID

Mode

Access ID

Type

VLAN Name

Source IP

Destination IP

Port

Description

This is the identifier number for this profile set.

Select Permit to specify that the packets that match the access profile are forwarded by the Switch, according to any additional rule added (see below).

Select Deny to specify that packets that do not match the access profile are not forwarded by the Switch and will be filtered.

Type in a unique identifier number for this access. This value can be set from 1 -

100.

Selected profile based on Ethernet (MAC Address), IP address or Packet Content.

Ethernet instructs the Switch to examine the layer 2 part of each packet header.

IP instructs the Switch to examine the IP address in each frame's header.

Packet Content Mask instructs the Switch to examine the packet header.

Allows the entry of a name for a previously configured VLAN.

Source IP Address - Enter an IP Address mask for the source IP address.

Destination IP Address- Enter an IP Address mask for the destination IP address.

The rule may be configured on a per-port basis by entering the port number of the switch.

To view the settings of a previously correctly configured rule, click screen:

in the Access Rule Table to view the following

Figure 7- 64. CPU Interface Filtering Rule Display - IP

139

xStack DGS-3400 Series Fast Ethernet Switch

The following window is the CPU Interface Filtering Rule Table for Packet Content.

Figure 7- 65. CPU Interface Filtering Rule Table – Packet Content

To remove a previously created rule, select it and click the button. To add a new Access Rule, click the Add button:

Figure 7- 66. CPU Interface Filtering Rule Configuration - Packet Content

140

xStack DGS-3400 Series Fast Ethernet Switch

To set the Access Rule for Ethernet, adjust the following parameters and click Apply.

Parameter

Profile ID

Mode

Access ID

Type

Offset

Port

Description

This is the identifier number for this profile set.

Select Permit to specify that the packets that match the access profile are forwarded by the Switch, according to any additional rule added (see below).

Select Deny to specify that packets that do not match the access profile are not forwarded by the Switch and will be filtered.

Type in a unique identifier number for this access. This value can be set from 1 -

100.

Selected profile based on Ethernet (MAC Address), IP address or Packet Content.

Ethernet instructs the Switch to examine the layer 2 part of each packet header.

IP instructs the Switch to examine the IP address in each frame's header.

Packet Content Mask instructs the Switch to examine the packet header.

This field will instruct the Switch to mask the packet header beginning with the offset value specified:

value (0-15) - Enter a value in hex form to mask the packet from the beginning of the packet to the 15th byte.

value (16-31) - Enter a value in hex form to mask the packet from byte 16 to byte

31.

value (32-47) - Enter a value in hex form to mask the packet from byte 32 to byte

47.

value (48-63) - Enter a value in hex form to mask the packet from byte 48 to byte

63.

value (64-79) - Enter a value in hex form to mask the packet from byte 64 to byte

79.

The rule may be configured on a per-port basis by entering the port number of the switch.

To view the settings of a previously correctly configured rule, click screen:

in the Access Rule Table to view the following

Figure 7- 67. CPU Interface Filtering Rule Display – Packet Content

141

xStack DGS-3400 Series Fast Ethernet Switch

Security

Traffic Control

Port Security

Port Lock Entities

802.1x

Access Authentication Control

Traffic Segmentation

SSL

SSH

142

Section 8

xStack DGS-3400 Series Fast Ethernet Switch

Traffic Control

On a computer network, packets such as Multicast packets and Broadcast packets continually flood the network as normal procedure. At times, this traffic may increase do to a malicious endstation on the network or a malfunctioning device, such as a faulty network card. Thus, switch throughput problems will arise and consequently affect the overall performance of the switch network. To help rectify this packet storm, the Switch implements two methods to monitor and control the situation.

Hardware: The packet storm is monitored using the Switch’s hardware to determine if too many packets are flooding the network, based on the threshold level provided by the user. Once a packet storm has been detected, the Switch will drop packets coming into the Switch until the storm has subsided. This method can be utilized by selecting the Drop option of the Action field in the window below.

Software: The device’s software will scan and monitor packets coming into the Switch by monitoring the

Switch’s chip counter. This method is only viable for Broadcast and Multicast storms because the chip only has counters for these two types of packets. Once a storm has been detected (that is, once the packet threshold set below has been exceeded), the Switch will shutdown the port to all incoming traffic with the exception of STP

BPDU packets for a time period, specified using the CountDown field. If this field times out and the packet storm continues, the port will be placed in a Shutdown Forever mode which will produce a warning message to be sent to the Trap Receiver. Once in Shutdown Forever mode, the only method of recovering this port is to manually recoup it using the Storm Control Recover setting seen in the figure below. To utilize the Software method of

Storm Control, choose the Shutdown option of the Action field in the window below.

Use the Traffic Control menu to enable or disable storm control and adjust the threshold for multicast and broadcast storms, as well as DLF (Destination Look Up Failure). To view the following window, click Security > Traffic Control:

Figure 8- 1. Traffic Control Settings and Traffic Control Table window

To configure Traffic Control, enable or disable the Broadcast Storm, Multicast Storm and DLF using their corresponding pull-down menus. Click Apply to implement changes made.

143

xStack DGS-3400 Series Fast Ethernet Switch

Parameter Description

Traffic Control Recover

From… To

Traffic Trap Configuration

Select the ports to be shutdown.

Traffic Trap Enable sending of Storm Trap messages when the type of action taken by the Traffic Control function in handling a Traffic Storm is one of the following:

None – Will send no Storm trap warning messages regardless of action taken by the Traffic

Control mechanism.

Storm Occurred – Will send Storm Trap warning messages upon the occurrence of a Traffic

Storm only.

Storm Cleared – Will send Storm Trap messages when a Traffic Storm has been cleared by the Switch only.

Both – Will send Storm Trap messages when a Traffic Storm has been both detected and cleared by the Switch.

This function cannot be implemented in the Hardware mode. (When Drop is chosen in the

Action field.

Storm Control Settings

Select the ports of this Switch to configure for Storm Control. From…To

Broadcast

Multicast

DLF

Enables or disable Broadcast Storm Control.

Enables or disables Multicast Storm Control.

Action

Threshold

Count Down

Interval

Enables or disables Destination Lookup Failure (DLF) storm control. (Not available for

Software based Traffic Control {Shutdown}).

Select the method of traffic Control from the pull down menu. The choices are:

Drop – Utilizes the hardware Traffic Control mechanism, which means the Switch’s hardware will determine the Packet Storm based on the Threshold value stated and drop packets until the issue is resovled.

Shutdown – Utilizes the Switch’s software Traffic Control mechanism to determine the

Packet Storm occurring. Once detected, the port will deny all incoming traffic to the port except STP BPDU packets, which are essential in keeping the Spanning Tree operational on the Switch. If the Countdown timer has expired and yet the Packet Storm continues, the port will be placed in Shutdown Forever mode and is no longer operational until the user manually resets the port using the Storm Control Recover setting at the top of this window.

Choosing this option obligates the user to configure the Interval setting as well, which will provide packet count samplings from the Switch’s chip to determine if a Packet Storm is occurring.

Specifies the maximum number of packets per second that will trigger the Traffic Control function to commence. This entry should be made in multiples of 128. Other entries will be set internally closest to the multiple of 128. The configurable threshold range is from 0-2047 with a default setting of 1024.

The Count Down timer is set to determine the amount of time, in minutes, that the Switch will wait before shutting down the port that is experiencing a traffic storm. This parameter is only useful for ports configured as Shutdown in their Action field and therefore will not operate for

Hardware based Traffic Control implementations. The possible time settings for this field are

0, 5-30 minutes. 0 is the default setting for this field and 0 will denote that the port will never shutdown.

The Interval will set the time between Multicast and Broadcast packet counts sent from the

Switch’s chip to the Traffic Control function. These packet counts are the determining factor in deciding when incoming packets exceed the Threshold value. The Interval may be set between 5 and 30 seconds with the default setting of 5 seconds.

Click Apply to implemet the settings of each field.

144

xStack DGS-3400 Series Fast Ethernet Switch

NOTE: Traffic Control cannot be implemented on ports that are set for

Link Aggregation (Port Trunking).

NOTE: Ports that are in the Shutdown forever mode will be seen as

Discarding in Spanning Tree windows and implementations though these ports will still be forwarding BDPUs to the Switch’s CPU.

NOTE: Ports that are in Shutdown Forever mode will be seen as link down in all windows and screens until the user recovers these ports.

145

xStack DGS-3400 Series Fast Ethernet Switch

Port Security

A given ports’ (or a range of ports') dynamic MAC address learning can be locked such that the current source MAC addresses entered into the MAC address forwarding table can not be changed once the port lock is enabled. The port can be locked by using the Admin State pulldown menu to Enabled, and clicking

Apply.

Port Security is a security feature that prevents unauthorized computers (with source MAC addresses) unknown to the

Switch prior to locking the port (or ports) from connecting to the Switch's locked ports and gaining access to the network. To view the following window, click Security

> Port Security.

Figure 8- 2. Port Security Settings and Table

The following parameters can be set:

Parameter

From/To

Admin State

Max. Learning Addr. (0-16)

Mode

Description

A consecutive group of ports may be configured starting with the selected port.

This pull-down menu allows the user to enable or disable Port Security

(locked MAC address table for the selected ports).

The number of MAC addresses that will be in the MAC address forwarding table for the selected switch and group of ports.

This pull-down menu allows the option of how the MAC address table locking will be implemented on the Switch, for the selected group of ports. The options are:

Permanent – The locked addresses will only age out after the Switch has been reset.

DeleteOnTimeout – The locked addresses will age out after the aging timer expires.

DeleteOnReset – The locked addresses will not age out until the Switch has been reset or rebooted.

Click Apply to implement changes made.

146

xStack DGS-3400 Series Fast Ethernet Switch

Port Lock Entries

The Port Lock Entry Delete window is used to remove an entry from the port security entries learned by the Switch and entered into the forwarding database. To view this window, click Security > Port Lock Entries.

This function is only operable if the Mode in the Port Security window is selected as

Permanent or DeleteOnReset, or in other words, only addresses that are permanently learned by the Switch can be deleted. Once the entry has been defined by entering the correct information into the window above, click the

under the Delete heading of the corres ponding MAC address to be deleted.

Click the Next button to view the next page of entries listed in this table.

Figure 8- 3. Port Lock Entries Table

This window displays the following information:

Parameter

VID

VLAN NAME

MAC Address

Port

Type

Description

The VLAN ID of the entry in the forwarding database table that has been permanently learned by the Switch.

The VLAN Name of the entry in the forwarding database table that has been permanently learned by the Switch.

The MAC address of the entry in the forwarding database table that has been permanently learned by the Switch.

The ID number of the port that has permanently learned the MAC address.

The type of MAC address in the forwarding database table. Only entries marked

Secured_Permanent can be deleted.

Delete

Click the in this field to delete the corresponding MAC address that was permanently learned by the Switch.

147

xStack DGS-3400 Series Fast Ethernet Switch

Configure 802.1x Authenticator

To configure the 802.1X authenticator settings, click Configuration > Port Access Entity > Configure 802.1x Authenti-

cator Parameter:

Figure 8- 4. Configure 802.1X Authenticator Parameter window

To view the 802.1X authenticator settings on a different switch in the switch STACK, use the UNIT pull-down menu to select that switch by its ID number in the switch STACK. To configure the settings by port, click on the hyperlinked port number under the Port heading, which will display the following table to configure:

Figure 8- 5. 802.1X Authenticator Settings – Modify

This screen allows setting of the following features:

148

xStack DGS-3400 Series Fast Ethernet Switch

Parameter

From [ ] To [ ]

AdmCtrlDir

PortControl

TxPeriod

QuietPeriod

SuppTimeout

ServerTimeout

MaxReq

ReAuthPeriod

ReAuth

Description

Enter the port or ports to be set.

Sets the administrative-controlled direction to either in or both.

If in is selected, control is only exerted over incoming traffic through the port selected in the first field.

If both is selected, control is exerted over both incoming and outgoing traffic through the controlled port selected in the first field.

This allows the user to control the port authorization state.

Select forceAuthorized to disable 802.1X and cause the port to transition to the authorized state without any authentication exchange required. This means the port transmits and receives normal traffic without 802.1X-based authentication of the client.

If forceUnauthorized is selected, the port will remain in the unauthorized state, ignoring all attempts by the client to authenticate. The Switch cannot provide authentication services to the client through the interface.

If Auto is selected, it will enable 802.1X and cause the port to begin in the unauthorized state, allowing only EAPOL frames to be sent and received through the port. The authentication process begins when the link state of the port transitions from down to up, or when an EAPOL-start frame is received. The Switch then requests the identity of the client and begins relaying authentication messages between the client and the authentication server.

The default setting is Auto.

This sets the TxPeriod of time for the authenticator PAE state machine. This value determines the period of an EAP Request/Identity packet transmitted to the client.

The default setting is 30 seconds.

This allows the user to set the number of seconds that the Switch remains in the quiet state following a failed authentication exchange with the client. The default setting is 60 seconds.

This value determines timeout conditions in the exchanges between the

Authenticator and the client. The default setting is 30 seconds.

This value determines timeout conditions in the exchanges between the

Authenticator and the authentication server. The default setting is 30 seconds.

The maximum number of times that the Switch will retransmit an EAP Request to the client before it times out of the authentication sessions. The default setting is 2.

A constant that defines a nonzero number of seconds between periodic reauthentication of the client. The default setting is 3600 seconds.

Determines whether regular reauthentication will take place on this port. The default setting is Disabled.

Click Apply to implement your configuration changes. To view configurations for the 802.1X Authenticator Settings on a port-by-port basis, see the 802.1X Authenticator Settings table.

149

xStack DGS-3400 Series Fast Ethernet Switch

RADIUS Server

The RADIUS feature of the Switch allows the user to facilitate centralized user administration as well as providing protection against a sniffing, active hacker. The Web Manager offers three windows.

Click Configuration > Port Access Entity > RADIUS Server > Authentic RADIUS Server to open the Authentic

RADIUS Server Setting window shown below:

Figure 8- 6. Authentic RADIUS Server and Current RADIUS Server Settings Table window

This window displays the following information:

Parameter

Succession

RADIUS Server

Authentic Port

Accounting Port

Key

Confirm Key

Status

Description

Choose the desired RADIUS server to configure: First, Second or Third.

Set the RADIUS server IP.

Set the RADIUS authentic server(s) UDP port. The default port is 1812.

Set the RADIUS account server(s) UDP port. The default port is 1813.

Set the key the same as that of the RADIUS server.

Confirm the shared key is the same as that of the RADIUS server.

This allows the user to set the RADIUS Server as Valid (Enabled) or Invalid

(Disabled).

150

xStack DGS-3400 Series Fast Ethernet Switch

Trusted Host

Up to four trusted-host secure IP addresses may be configured and used for remote Switch management. It should be noted that if one or more trusted hosts are enabled, the Switch will immediately accept remote instructions from only the specified IP address or addresses. If you enable this feature be sure to first enter the IP address of the station you are currently using.

Figure 8- 7. Security IP menu for Trusted Host configuration

To configure secure IP addresses for trusted host management of the Switch, type the IP address of the station you are currently using in the first field as well as up to three additional IP addresses of trusted hosts. Click the Apply button to assigen trusted host status to the IP addresses. This goes into effect immediately.

151

xStack DGS-3400 Series Fast Ethernet Switch

Access Authentication Control

The TACACS / XTACACS / TACACS+ / RADIUS commands let you secure access to the Switch using the TACACS /

XTACACS / TACACS+ / RADIUS protocols. When a user logs in to the Switch or tries to access the administrator level privilege, he or she is prompted for a password. If TACACS / XTACACS / TACACS+ / RADIUS authentication is enabled on the Switch, it will contact a TACACS / XTACACS / TACACS+ / RADIUS server to verify the user. If the user is verified, he or she is granted access to the Switch.

There are currently three versions of the TACACS security protocol, each a separate entity. The Switch's software supports the following versions of TACACS:

TACACS (Terminal Access Controller Access Control System) - Provides password checking and authentication, and notification of user actions for security purposes utilizing via one or more centralized TACACS servers, utilizing the UDP protocol for packet transmission.

Extended TACACS (XTACACS) - An extension of the TACACS protocol with the ability to provide more types of authentication requests and more types of response codes than TACACS. This protocol also uses UDP to transmit packets.

TACACS+ (Terminal Access Controller Access Control System plus) - Provides detailed access control for authentication for network devices. TACACS+ is facilitated through Authentication commands via one or more centralized servers. The TACACS+ protocol encrypts all traffic between the Switch and the TACACS+ daemon, using the TCP protocol to ensure reliable delivery

In order for the TACACS / XTACACS / TACACS+ / RADIUS security function to work properly, a TACACS /

XTACACS / TACACS+ / RADIUS server must be configured on a device other than the Switch, called an Authentication

Server Host and it must include usernames and passwords for authentication. When the user is prompted by the Switch to enter usernames and passwords for authentication, the Switch contacts the TACACS / XTACACS / TACACS+ / RADIUS server to verify, and the server will respond with one of three messages:

The server verifies the username and password, and the user is granted normal user privileges on the Switch.

The server will not accept the username and password and the user is denied access to the Switch.

The server doesn't respond to the verification query. At this point, the Switch receives the timeout from the server and then moves to the next method of verification configured in the method list.

The Switch has four built-in Authentication Server Groups, one for each of the TACACS, XTACACS, TACACS+ and

RADIUS protocols. These built-in Authentication Server Groups are used to authenticate users trying to access the Switch.

The users will set Authentication Server Hosts in a preferable order in the built-in Authentication Server Groups and when a user tries to gain access to the Switch, the Switch will ask the first Authentication Server Hosts for authentication. If no authentication is made, the second server host in the list will be queried, and so on. The built-in Authentication Server

Groups can only have hosts that are running the specified protocol. For example, the TACACS Authentication Server

Groups can only have TACACS Authentication Server Hosts.

The administrator for the Switch may set up six different authentication techniques per user-defined method list (TACACS

/ XTACACS / TACACS+ / RADIUS / local / none) for authentication. These techniques will be listed in an order preferable, and defined by the user for normal user authentication on the Switch, and may contain up to eight authentication techniques. When a user attempts to access the Switch, the Switch will select the first technique listed for authentication. If the first technique goes through its Authentication Server Hosts and no authentication is returned, the

Switch will then go to the next technique listed in the server group for authentication, until the authentication has been verified or denied, or the list is exhausted.

Please note that users granted access to the Switch will be granted normal user privileges on the Switch. To gain access to administrator level privileges, the user must access the Enable Admin window and then enter a password, which was previously configured by the administrator of the Switch.

NOTE: TACACS, XTACACS and TACACS+ are separate entities and are not compatible. The Switch and the server must be configured exactly the same, using the same protocol. (For example, if the Switch is set up for TACACS authentication, so must be the host server.)

152

xStack DGS-3400 Series Fast Ethernet Switch

Authentication Policy & Parameters

This command will enable an administrator-defined authentication policy for users trying to access the Switch. When enabled, the device will check the Login Method List and choose a technique for user authentication upon login.

To access the following window, click Security > Access Authentication Control > Authentication Policy &

Parameter Settings:

Figure 8- 8. Authentication Policy and Parameter Settings window

The following parameters can be set:

Parameter

Authentication Policy

Response Timeout (1-

255)

User Attempts (1-255)

Description

Use the pull down menu to enable or disable the Authentication Policy on the

Switch.

This field will set the time the Switch will wait for a response of authentication from the user. The user may set a time between 1 and 255 seconds. The default setting is 30 seconds.

This command will configure the maximum number of times the Switch will accept authentication attempts. Users failing to be authenticated after the set amount of attempts will be denied access to the Switch and will be locked out of further authentication attempts. Command line interface users will have to wait 60 seconds before another authentication attempt. TELNET and web users will be disconnected from the Switch. The user may set the number of attempts from 1 to

255. The default setting is 3.

Click Apply to implement changes made.

Application's Authentication Settings

This window is used to configure switch configuration applications (console, Telnet, SSH, web) for login at the user level and at the administration level (Enable Admin) utilizing a previously configured method list. To view the following window, click Security Management > Access Authentication Control > Application Authentication Settings:

Figure 8- 9. Application's Authentication Settings window

The following parameters can be set:

153

xStack DGS-3400 Series Fast Ethernet Switch

Parameter

Application

Login Method List

Enable Method List

Description

Lists the configuration applications on the Switch. The user may configure the

Login Method List and Enable Method List for authentication for users utilizing the

Console (Command Line Interface) application, the Telnet application, SSH and the

Web (HTTP) application.

Using the pull down menu, configure an application for normal login on the user level, utilizing a previously configured method list. The user may use the default

Method List or other Method List configured by the user. See the Login Method

Lists window, in this section, for more information.

Using the pull down menu, configure an application for normal login on the user level, utilizing a previously configured method list. The user may use the default

Method List or other Method List configured by the user. See the Enable Method

Lists window, in this section, for more information

Click Apply to implement changes made.

Authentication Server Group

This window will allow users to set up Authentication Server Groups on the Switch. A server group is a technique used to group TACACS/XTACACS/TACACS+/RADIUS server hosts into user-defined categories for authentication using method lists. The user may define the type of server group by protocol or by previously defined server group. The Switch has three built-in Authentication Server Groups that cannot be removed but can be modified. Up to eight authentication server hosts may be added to any particular group.

To view the following window, click Security Management > Access Authentication Control > Authentication Server

Group:

Figure 8- 10. Authentication Server Group window

This screen displays the Authentication Server Groups on the Switch. The Switch has four built-in Authentication Server

Groups that cannot be removed but can be modified. To modify a particular group, click its hyperlinked Group Name, which will then display the following window.

Figure 8- 11. Add a Server Host to Server Group (XTACACS) window.

To add an Authentication Server Host to the list, enter its IP address in the IP Address field, choose the protocol associated with the IP address of the Authentication Server Host and click Add to add this Authentication Server Host to the group.

154

xStack DGS-3400 Series Fast Ethernet Switch

To add a server group other than the ones listed, click the add button, revealing the following window to configure.

Figure 8- 12. Authentication Server Group Table Add Settings window

Enter a group name of up to 15 characters into the Group Name field and click Apply. The entry should appear in the

Authentication Server Group Settings window, as shown in Figure 8-12 (Trinity).

NOTE: The user must configure Authentication Server Hosts using the Authentication Server

Hosts window before adding hosts to the list. Authentication Server Hosts must be configured for their specific protocol on a remote centralized server before this function can work properly.

NOTE: The three built in server groups can only have server hosts running the same TACACS daemon. TACACS/XTACACS/TACACS+ protocols are separate entities and are not compatible with each other.

Authentication Server Host

This window will set user-defined Authentication Server Hosts for the TACACS / XTACACS / TACACS+ / RADIUS security protocols on the Switch. When a user attempts to access the Switch with Authentication Policy enabled, the

Switch will send authentication packets to a remote TACACS / XTACACS / TACACS+ / RADIUS server host on a remote host. The TACACS / XTACACS / TACACS+ / RADIUS server host will then verify or deny the request and return the appropriate message to the Switch. More than one authentication protocol can be run on the same physical server host but, remember that TACACS / XTACACS / TACACS+ / RADIUS are separate entities and are not compatible with each other. The maximum supported number of server hosts is 16.

To view the following window, click Security Management > Access Authentication Control > Authentication Server

Host:

Figure 8- 13. Authentication Server Host window

To add an Authentication Server Host, click the Add button, revealing the following window:

155

xStack DGS-3400 Series Fast Ethernet Switch

Figure 8- 14. Authentication Server Host Setting - Add window

Configure the following parameters to add an Authentication Server Host:

Parameter

IP Address

Protocol

Port (1-65535)

Timeout (1-255)

Retransmit (1-255)

Key

Description

The IP address of the remote server host to add.

The protocol used by the server host. The user may choose one of the following:

TACACS - Enter this parameter if the server host utilizes the TACACS protocol.

XTACACS - Enter this parameter if the server host utilizes the XTACACS protocol.

TACACS+ - Enter this parameter if the server host utilizes the TACACS+ protocol.

RADIUS - Enter this parameter if the server host utilizes the RADIUS protocol.

Enter a number between 1 and 65535 to define the virtual port number of the authentication protocol on a server host. The default port number is 49 for

TACACS/XTACACS/TACACS+ servers and 1813 for RADIUS servers but the user may set a unique port number for higher security.

Enter the time in seconds the Switch will wait for the server host to reply to an authentication request. The default value is 5 seconds.

Enter the value in the retransmit field to change how many times the device will resend an authentication request when the TACACS server does not respond.

Authentication key to be shared with a configured TACACS+ or RADIUS servers only. Specify an alphanumeric string up to 254 characters.

Click Apply to add the server host.

NOTE: More than one authentication protocol can be run on the same physical server host but, remember that TACACS/XTACACS/TACACS+ are separate entities and are not compatible with each other

Login Method Lists

This command will configure a user-defined or default Login Method List of authentication techniques for users logging on to the Switch. The sequence of techniques implemented in this command will affect the authentication result. For example, if a user enters a sequence of techniques, for example TACACS - XTACACS- local, the Switch will send an authentication request to the first TACACS host in the server group. If no response comes from the server host, the Switch will send an authentication request to the second TACACS host in the server group and so on, until the list is exhausted. At that point, the Switch will restart the same sequence with the following protocol listed, XTACACS. If no authentication takes place using the XTACACS list, the local account database set in the Switch is used to authenticate the user. When the local method is used, the privilege level will be dependant on the local account privilege configured on the Switch.

156

xStack DGS-3400 Series Fast Ethernet Switch

Successful login using any of these techniques will give the user a "User" privilege only. If the user wishes to upgrade his or her status to the administrator level, the user must use the Enable Admin window, in which the user must enter a previously configured password, set by the administrator. (See the Enable Admin part of this section for more detailed information concerning the Enable Admin command.)

To view the following screen click Security Management > Access Authentication Control > Login Method Lists:

Figure 8- 15. Login Method List Settings window

The Switch contains one Method List that is set and cannot be removed, yet can be modified. To delete a Login Method

List defined by the user, click the under the Delete heading corresponding to the entry desired to be deleted. To modify a Login Method List, click on its hyperlinked Method List Name. To configure a new Method List, click the Add button.

Both actions will result in the same screen to configure:

Figure 8- 16. Login Method List - Edit window (default)

Figure 8- 17. Login Method List – Add window

To define a Login Method List, set the following parameters and click Apply:

157

xStack DGS-3400 Series Fast Ethernet Switch

Parameter

Method List Name

Method 1, 2, 3, 4

Description

Enter a method list name defined by the user of up to 15 characters.

The user may add one, or a combination of up to four (4) of the following authentication methods to this method list:

tacacs - Adding this parameter will require the user to be authenticated using the

TACACS protocol from a remote TACACS server.

xtacacs - Adding this parameter will require the user to be authenticated using the

XTACACS protocol from a remote XTACACS server.

tacacs+ - Adding this parameter will require the user to be authenticated using the

TACACS+ protocol from a remote TACACS+ server.

radius - Adding this parameter will require the user to be authenticated using the

RADIUS protocol from a remote RADIUS server.

server_group - Adding this parameter will require the user to be authenticated using a user-defined server group previously configured on the Switch.

local - Adding this parameter will require the user to be authenticated using the local user account database on the Switch. none - Adding this parameter will require no authentication to access the Switch.

Enable Method Lists

The Enable Method Lists window is used to set up Method Lists to promote users with user level privileges to

Administrator (Admin) level privileges using authentication methods on the Switch. Once a user acquires normal user level privileges on the Switch, he or she must be authenticated by a method on the Switch to gain administrator privileges on the

Switch, which is defined by the Administrator. A maximum of eight (8) Enable Method Lists can be implemented on the

Switch, one of which is a default Enable Method List. This default Enable Method List cannot be deleted but can be configured.

The sequence of methods implemented in this command will affect the authentication result. For example, if a user enters a sequence of methods like TACACS - XTACACS - Local Enable, the Switch will send an authentication request to the first

TACACS host in the server group. If no verification is found, the Switch will send an authentication request to the second

TACACS host in the server group and so on, until the list is exhausted. At that point, the Switch will restart the same sequence with the following protocol listed, XTACACS. If no authentication takes place using the XTACACS list, the

Local Enable password set in the Switch is used to authenticate the user.

Successful authentication using any of these methods will give the user an "Admin" privilege.

NOTE: To set the Local Enable Password, see the next section, entitled Local Enable Password.

To view the following table, click Security Management > Access Authentication Control > Enable Method Lists:

Figure 8- 18. Enable Method List Settings window

To delete an Enable Method List defined by the user, click the under the Delete heading corresponding to the entry desired to be deleted. To modify an Enable Method List, click on its hyperlinked Method List Name. To configure a

Method List, click the Add button.

158

xStack DGS-3400 Series Fast Ethernet Switch

Both actions will result in the same screen to configure:

Figure 8- 19. Enable Method List - Edit window

Figure 8- 20. Enable Method List - Add window

To define an Enable Login Method List, set the following parameters and click Apply:

Parameter

Method List Name

Method 1, 2, 3, 4

Description

Enter a method list name defined by the user of up to 15 characters.

The user may add one, or a combination of up to four (4) of the following authentication methods to this method list:

local_enable - Adding this parameter will require the user to be authenticated using the local enable password database on the Switch. The local enable password must be set by the user in the next section entitled Local Enable Password.

none - Adding this parameter will require no authentication to access the Switch.

radius - Adding this parameter will require the user to be authenticated using the

RADIUS protocol from a remote RADIUS server.

tacacs - Adding this parameter will require the user to be authenticated using the

TACACS protocol from a remote TACACS server.

xtacacs - Adding this parameter will require the user to be authenticated using the

XTACACS protocol from a remote XTACACS server.

tacacs+ - Adding this parameter will require the user to be authenticated using the

TACACS protocol from a remote TACACS server. server_group - Adding a previously configured server group will require the user to be authenticated using a user-defined server group previously configured on the

Switch.

159

xStack DGS-3400 Series Fast Ethernet Switch

Local Enable Password

This window will configure the locally enabled password for the Enable Admin command. When a user chooses the

"local_enable" method to promote user level privileges to administrator privileges, he or she will be prompted to enter the password configured here that is locally set on the Switch.

To view the following window, click Security Management > Access Authentication Control > Local Enable

Password:

Figure 8- 21. Configure Local Enable Password window

To set the Local Enable Password, set the following parameters and click Apply.

Parameter

Old Local Enable

New Local Enable

Confirm Local Enable

Description

If a password was previously configured for this entry, enter it here in order to change it to a new password

Enter the new password that you wish to set on the Switch to authenticate users attempting to access Administrator Level privileges on the Switch. The user may set a password of up to 15 characters.

Confirm the new password entered above. Entering a different password here from the one set in the New Local Enabled field will result in a fail message.

Click Apply to implement changes made.

Enable Admin

The Enable Admin window is for users who have logged on to the Switch on the normal user level, and wish to be promoted to the administrator level. After logging on to the Switch, users will have only user level privileges. To gain access to administrator level privileges, the user will open this window and will have to enter an authentication password.

Possible authentication methods for this function include TACACS/XTACACS/TACACS+/RADIUS, user defined server groups, local enable (local account on the Switch), or no authentication (none). Because XTACACS and TACACS do not support the enable function, the user must create a special account on the server host, which has the username "enable", and a password configured by the administrator that will support the "enable" function. This function becomes inoperable when the authentication policy is disabled.

To view the following window, click Security > Access Authentication Control > Enable Admin:

Figure 8- 22. Enable Admin Screen

When this screen appears, click the Enable Admin button revealing a window for the user to enter authentication

(password, username), as seen below. A successful entry will promote the user to Administrator level privileges on the

Switch.

160

xStack DGS-3400 Series Fast Ethernet Switch

Traffic Segmentation

Traffic segmentation is used to limit traffic flow from a single port to a group of ports. This method of segmenting the flow of traffic is similar to using VLANs to limit traffic, but is more restrictive. It provides a method of directing traffic that does not increase the overhead of the Master switch CPU.

Open the Security folder and click Traffic Segmentation, to view the screen shown below.

Figure 8- 23. Current Traffic Segmentation Table

Click on the Setup button to open the Setup Forwarding ports menu, as shown below.

Figure 8- 24. Setup Forwarding Ports

Configuring traffic segmentation on the xStack DGS-3400 switch series is accomplished in two parts. First, specify a port from the switch, using the Port pull-down menu. Then specify which ports on the switch that are able to receive packets from the switch and port specified in the first part.

Clicking the Apply button will enter the combination of transmitting port and allowed receiving ports into the Switch’s

Traffic Segmentation table.

161

xStack DGS-3400 Series Fast Ethernet Switch

Secure Socket Layer (SSL)

Secure Sockets Layer or SSL is a security feature that will provide a secure communication path between a host and client through the use of authentication, digital signatures and encryption. These security functions are implemented through the use of a ciphersuite, which is a security string that determines the exact cryptographic parameters, specific encryption algorithms and key sizes to be used for an authentication session and consists of three levels: utilizes the Rivest Shamir Adleman (RSA) public key algorithm and the Digital Signature Algorithm (DSA), specified here as the DHE DSS Diffie-Hellman (DHE) public key algorithm. This is the first authentication process between client and host as they “exchange keys” in looking for a match and therefore authentication to be accepted to negotiate encryptions on the following level.

2. Encryption: The second part of the ciphersuite that includes the encryption used for encrypting the messages sent between client and host. The Switch supports two types of cryptology algorithms:

Stream Ciphers – There are two types of stream ciphers on the Switch, RC4 with 40-bit keys and RC4 with 128-bit keys.

These keys are used to encrypt messages and need to be consistent between client and host for optimal use.

CBC Block Ciphers – CBC refers to Cipher Block Chaining, which means that a portion of the previously encrypted block of encrypted text is used in the encryption of the current block. The Switch supports the 3DES EDE encryption code defined by the Data Encryption Standard (DES) to create the encrypted text. determine a Message Authentication Code. This Message Authentication Code will be encrypted with a sent message to provide integrity and prevent against replay attacks. The Switch supports two hash algorithms, MD5

(Message Digest 5) and SHA (Secure Hash Algorithm).

These three parameters are uniquely assembled in four choices on the Switch to create a three-layered encryption code for secure communication between the server and the host. The user may implement any one or combination of the ciphersuites available, yet different ciphersuites will affect the security level and the performance of the secured connection. The information included in the ciphersuites is not included with the Switch and requires downloading from a third source in a file form called a certificate. This function of the Switch cannot be executed without the presence and implementation of the certificate file and can be downloaded to the Switch by utilizing a TFTP server. The Switch supports

SSLv3. Other versions of SSL may not be compatible with this Switch and may cause problems upon authentication and transfer of messages from client to host.

Download Certificate

This window is used to download a certificate file for the SSL function on the Switch from a TFTP server. The certificate file is a data record used for authenticating devices on the network. It contains information on the owner, keys for authentication and digital signatures. Both the server and the client must have consistent certificate files for optimal use of the SSL function. The Switch only supports certificate files with .der file extensions. Currently, all xStack DGS-3400

Series switch come with a certificate pre-loaded though the user may need to download more, depending on user circumstances.

162

xStack DGS-3400 Series Fast Ethernet Switch

To view the following window, click Security Management > SSL at the top of the window:

Figure 8- 25. Download Certificate menu

To download certificates, set the following parameters and click Apply.

Parameter

Certificate Type

Server IP

Certificate File Name

Key File Name

Description

Select Local or ??????????? to specifiy certificate type.

Enter the IP address of the TFTP server where the certificate files are located.

Enter the path and the filename of the certificate file to download. This file must have a .der extension. (Ex. c:/cert.der)

Enter the path and the filename of the key file to download. This file must have a .der extension (Ex. c:/pkey.der)

Click Apply to implement changes made.

SSL Configuration

This screen will allow the user to enable SSL on the Switch and implement any one or combination of listed ciphersuites on the Switch. A ciphersuite is a security string that determines the exact cryptographic parameters, specific encryption algorithms and key sizes to be used for an authentication session. The Switch possesses four possible ciphersuites for the

SSL function, which are all enabled by default. To utilize a particular ciphersuite, disable the unwanted ciphersuites, leaving the desired one for authentication.

When the SSL function has been enabled, the web will become disabled. To manage the Switch through the web based management while utilizing the SSL function, the web browser must support SSL encryption and the header of the URL must begin with https://. (Ex. https://xx.xx.xx.xx) Any other method will result in an error and no access can be authorized for the web-based management.

163

xStack DGS-3400 Series Fast Ethernet Switch

To view the following window, click Security > SSL:

Figure 8- 26. SSL Configuration and Ciphersuite menu

To set up the SSL function on the Switch, configure the following parameters and click Apply.

Parameter Description

SL Configuration

SSL Status

Cache Timeout (60-

86400)

Use the pull down menu to enable or disable the SSL status on the switch. The default is Disabled.

This field will set the time between a new key exchange between a client and a host using the SSL function. A new SSL session is established every time the client and host go through a key exchange. Specifying a longer timeout will allow the SSL session to reuse the master key on future connections with that particular host, therefore speeding up the negotiation process. The default setting is 600 seconds.

SSL Ciphersuite

RSA with RC4 128 MD5 This ciphersuite combines the RSA key exchange, stream cipher RC4 encryption with 128-bit keys and the MD5 Hash Algorithm. Use the pull down menu to enable or disable this ciphersuite. This field is Enabled by default.

RSA with 3DES EDE

CBC SHA

DHS DSS with 3DES EDE

CBC SHA

This ciphersuite combines the RSA key exchange, CBC Block Cipher 3DES_EDE encryption and the SHA Hash Algorithm. Use the pull down menu to enable or disable this ciphersuite. This field is Enabled by default.

This ciphersuite combines the DSA Diffie Hellman key exchange, CBC Block

Cipher 3DES_EDE encryption and SHA Hash Algorithm. Use the pull down menu to enable or disable this ciphersuite. This field is Enabled by default.

RSA EXPORT with RC4

40 MD5

This ciphersuite combines the RSA Export key exchange and stream cipher RC4 encryption with 40-bit keys. Use the pull down menu to enable or disable this ciphersuite. This field is Enabled by default.

NOTE: Certain implementations concerning the function and configuration of SSL are not available on the web-based management of this Switch and need to be configured using the command line interface.

NOTE: Enabling the SSL command will disable the web-based switch management.

To log on to the Switch again, the header of the URL must begin with https://. Entering anything else into the address field of the web browser will result in an error and no authentication will be granted.

164

xStack DGS-3400 Series Fast Ethernet Switch

Secure Shell (SSH)

SSH is an abbreviation of Secure Shell, which is a program allowing secure remote login and secure network services over an insecure network. It allows a secure login to remote host computers, a safe method of executing commands on a remote end node, and will provide secure encrypted and authenticated communication between two non-trusted hosts. SSH, with its array of unmatched security features is an essential tool in today’s networking environment. It is a powerful guardian against numerous existing security hazards that now threaten network communications.

The steps required to use the SSH protocol for secure communication between a remote PC (the SSH client) and the

Switch (the SSH server) are as follows:

1. Create a user account with admin-level access using the User Accounts window in the Security Management folder. This is identical to creating any other admin-level User Account on the Switch, including specifying a password. This password is used to logon to the Switch, once a secure communication path has been established using the SSH protocol.

2. Configure the User Account to use a specified authorization method to identify users that are allowed to establish

SSH connections with the Switch using the SSH User Authentication window. There are three choices as to the method SSH will use to authorize the user, which are Host Based, Password and Public Key.

3. Configure the encryption algorithm that SSH will use to encrypt and decrypt messages sent between the SSH client and the SSH server, using the SSH Algorithm window.

4. Finally, enable SSH on the Switch using the SSH Configuration window.

After completing the preceding steps, a SSH Client on a remote PC can be configured to manage the Switch using a secure, in band connection.

SSH Configuration

The following window is used to configure and view settings for the SSH server and can be opened by clicking Security

Management > Secure Shell (SSH) > SSH Configuration:

Figure 8- 27. Current SSH Configuration and SSH Seerver Configuration Settings menu

165

xStack DGS-3400 Series Fast Ethernet Switch

To configure the SSH server on the Switch, modify the following parameters and click Apply:

Parameter

SSH Server Status

Max Session (1-8)

Connection TimeOut

(120-600)

Auth. Fail (2-20)

Session Rekeying

Port

Description

Use the pull-down menu to enable or disable SSH on the Switch. The default is

Disabled.

Enter a value between 1 and 8 to set the number of users that may simultaneously access the Switch. The default setting is 8.

Allows the user to set the connection timeout. The use may set a time between 120 and 600 seconds. The default setting is 120 seconds.

Allows the Administrator to set the maximum number of attempts that a user may try to log on to the SSH Server utilizing the SSH authentication. After the maximum number of attempts has been exceeded, the Switch will be disconnected and the user must reconnect to the Switch to attempt another login. The number of maximum attempts may be set between 2 and 20. The default setting is 2.

This field is used to set the time period that the Switch will change the security shell encryptions by using the pull-down menu. The available options are Never, 10 min,

30 min, and 60 min. The default setting is Never.

Enter the virtual port number to be used with this feature. The common port number for SSH is 22.

SSH Algorithm

The SSH Algorithm window allows the configuration of the desired types of SSH algorithms used for authentication encryption. There are three categories of algorithms listed and specific algorithms of each may be enabled or disabled by using their corresponding pull-down menus. All algorithms are enabled by default. To open the following window, click

Security > SSH > SSH Authentication Mode and Algorithm Settings:

Figure 8- 28. SSH Algorithms window

The following algorithms may be set:

166

xStack DGS-3400 Series Fast Ethernet Switch

Parameter Description

Authentication Algorithm

Password

Public Key

Host-based

This field may be enabled or disabled to choose if the administrator wishes to use a locally configured password for authentication on the Switch. This field is Enabled by default.

This field may be enabled or disabled to choose if the administrator wishes to use a publickey configuration set on a SSH server, for authentication. This field is

Enabled by default.

This field may be enabled or disabled to choose if the administrator wishes to use a host computer for authentication. This parameter is intended for Linux users requiring SSH authentication techniques and the host computer is running the

Linux operating system with a SSH program previously installed. This field is

Enabled by default.

Encryption Algorithm

3DES-CBC

Blow-fish CBC

AES128-CBC

Use the pull-down to enable or disable the Triple Data Encryption Standard encryption algorithm with Cipher Block Chaining. The default is Enabled.

Use the pull-down to enable or disable the Blowfish encryption algorithm with

Cipher Block Chaining. The default is Enabled.

Use the pull-down to enable or disable the Advanced Encryption Standard AES128 encryption algorithm with Cipher Block Chaining. The default is Enabled.

AES192-CBC

AES256-CBC

ARC4

Cast128-CBC

Twofish128

Twofish192

Twofish256

Use the pull-down to enable or disable the Advanced Encryption Standard AES192 encryption algorithm with Cipher Block Chaining. The default is Enabled.

Use the pull-down to enable or disable the Advanced Encryption Standard AES-

256 encryption algorithm with Cipher Block Chaining. The default is Enabled.

Use the pull-down to enable or disable the Arcfour encryption algorithm with Cipher

Block Chaining. The default is Enabled.

Use the pull-down to enable or disable the Cast128 encryption algorithm with

Cipher Block Chaining. The default is Enabled.

Use the pull-down to enable or disable the twofish128 encryption algorithm. The default is Enabled.

Use the pull-down to enable or disable the twofish192 encryption algorithm. The default is Enabled.

Use the pull-down to enable or disable the twofish256 encryption algorithm. The default is Enabled.

Data Integrity Algorithm

HMAC-RSA

HMAC-DSA

Use the pull-down to enable or disable the HMAC (Hash for Message

Authentication Code) mechanism utilizing the RSA encryption algorithm. The default is Enabled.

Use the pull-down to enable or disable the HMAC (Hash for Message

Authentication Code) mechanism utilizing the Digital Signature Algorithm (DSA) encryption. The default is Enabled.

Click Apply to implement changes made.

167

xStack DGS-3400 Series Fast Ethernet Switch

SSH User Authentication Mode

The following windows are used to configure parameters for users attempting to access the Switch through SSH. To access the following window, click Security Management > Secure Shell > SSH User Authentication.

Figure 8- 29. Current Accounts window

In the example screen above, the User Account “Darren” has been previously set using the User Accounts window in the

Security Management folder. A User Account MUST be set in order to set the parameters for the SSH user. To configure the parameters for a SSH user, click on the hyperlinked User Name in the Current Accounts window, which will reveal the following window to configure.

NOTE: To set the

SSH User

Authentication parameters on the

Switch, a User

Account must be previously configured.

Figure 8- 30. SSH User menu

The user may set the following parameters:

Parameter

User Name

Auth. Mode

Host Name

Host IP

Description

Enter a User Name of no more than 15 characters to identify the SSH user. This

User Name must be a previously configured user account on the Switch.

The administrator may choose one of the following to set the authorization for users attempting to access the Switch.

Host Based – This parameter should be chosen if the administrator wishes to use a remote SSH server for authentication purposes. Choosing this parameter requires the user to input the following information to identify the SSH user.

Host Name – Enter an alphanumeric string of no more than 32 characters to identify the remote SSH user.

Host IP – Enter the corresponding IP address of the SSH user.

Password – This parameter should be chosen if the administrator wishes to use an administrator-defined password for authentication. Upon entry of this parameter, the Switch will prompt the administrator for a password, and then to re-type the password for confirmation.

Public Key – This parameter should be chosen if the administrator wishes to use the publickey on a SSH server for authentication.

Enter an alphanumeric string of no more than 32 characters to identify the remote

SSH user. This parameter is only used in conjunction with the Host Based choice in the Auth. Mode field.

Enter the corresponding IP address of the SSH user. This parameter is only used in conjunction with the Host Based choice in the Auth. Mode field.

Click Apply to implement changes made.

168

xStack DGS-3400 Series Fast Ethernet Switch

Section 9

Save, Reset and Reboot

Saving Changes

Reboot System

Reset Configuration

Save Changes

The Switch has two levels of memory, normal RAM and non-volatile or NV-RAM. Configuration changes are made effective clicking the Save button. When this is done, the settings will be immediately applied to the switching software in

RAM, and will immediately take effect.

Some settings, though, require you to restart the Switch before they will take effect. Restarting the Switch erases all settings in RAM and reloads the stored settings from the NV-RAM. Thus, it is necessary to save all setting changes to NV-

RAM before rebooting the switch.

To retain any configuration changes permanently, click on the Save button in the Save Changes menu. The save optionas allow one alternative configuration image to be stored.

Figure 9- 1. Save Changes menu

The Save Changes options include:

Save Configuration_ID_1 to save the configuration file indexed as Image file 1. To use this file for configuration it must be designated as the Boot configuration using the Config Currnet Setting menu (Save Services > Config

Current Setting)

Save Configuration_ID_2 to save the configuration file indexed as Image file 2. To use this file for configuration it must be designated as the Boot configuration using the Config Currnet Setting menu (Save Services > Config

Current Setting)

Save Log to save only the current log.

Save All to save the current configuration file indexed as Image file 1 and save the current log.

169

xStack DGS-3400 Series Fast Ethernet Switch

Reset

The Reset function has several options when resetting the Switch. Some of the current configuration parameters can be retained while resetting all other configuration parameters to their factory defaults.

NOTE: Only the Reset System option will enter the factory default parameters into the

Switch’s non-volatile RAM, and then restart the Switch. All other options enter the factory defaults into the current configuration, but do not save this configuration. Reset System will return the Switch’s configuration to the state it was when it left the factory

Figure 9- 2. Reset options

Reboot System

The following menu is used to restart the Switch.

Figure 9- 3. Reboot System

Clicking the Yes click-box will instruct the Switch to save the current configuration to non-volatile RAM before restarting the Switch.

Clicking the No click-box instructs the Switch not to save the current configuration before restarting the Switch. All of the configuration information entered from the last time Save Changes was executed, will be lost.

Click the Restart button to restart the Switch.

Logout

Use the Logout page to logout of the Switch’s Web-based management agent by clicking on the Log Out button.

170

xStack DGS-3400 Series Fast Ethernet Switch

Section 10

Monitoring

Device Status

Module Information

CPU Utilization

Port Utilization

Packets

Errors

Packet Size

Browse Router Port

VLAN Status

Port Access Control

MAC Address Table

Switch Log

IGMP Snooping Group

IGMP Snooping Forward

Browse ARP Table

Session Table

171

xStack DGS-3400 Series Fast Ethernet Switch

Device Status

The Device Status window can be found in the Monitoring menu by clicking the Device Status link. This window shows the status of the physical attributes of the Switch, including power sources and fans.

Figure 10- 1. Device Status window

The following fields may be viewed in this window:

Parameter

Internal Power

External Power

(RPS)

Side Fan

Back Fan

Description

Displays Active if the internal power supply is powering the system.

Displays Active if the RPS is powering the system.

Indicates fan status.

Indicates fan status.

Module Information

The Module Information display in the Monitoring menu shows information about any installed modules.

Figure 10- 2. Module Information

Module information displayed:

Parameter

ID

Module Name

Rev. No.

Serial

Description

Description

The slot number where the module is installed.

The full name of the module installed.

The version of the installed module.

The serial number of the module.

A brief description of the type of module.

172

xStack DGS-3400 Series Fast Ethernet Switch

CPU Utilization

The CPU Utilization displays the percentage of the CPU being used, expressed as an integer percentage and calculated as a simple average by time interval. To view the CPU Utilization window, open the Monitoring folder and click the CPU

Utilization link.

Figure 10- 3. CPU Utilization graph

To view the CPU utilization by port, use the real-time graphic of the Switch and/or switch stack at the top of the web page by simply clicking on a port. Click Apply to implement the configured settings. The window will automatically refresh with new updated statistics.

Change the view parameters as follows:

Parameter

Time Interval [1s ]

Record Number [200]

Description

Select the desired setting between 1s and 60s, where "s" stands for seconds. The default value is one second.

Select number of times the Switch will be polled between 20 and 200. The default value is 200.

173

xStack DGS-3400 Series Fast Ethernet Switch

Port Utilization

The Port Utilization page displays the percentage of the total available bandwidth being used on the port.

To view the port utilization, open the Monitoring folder and then the Port Utilization link:

Figure 10- 4. Port Utilization window

To select a port to view these statistics for, first select the line card slot in the chassis switch by using the Unit pull-down menu and then select the port by using the Port pull down menu. The user may also use the real-time graphic of the Switch and/or switch stack at the top of the web page by simply clicking on a port.

Change the view parameters as follows:

Parameter

Time Interval [1s ]

Record Number [200]

Description

Select the desired setting between 1s and 60s, where "s" stands for seconds. The default value is one second.

Select number of times the Switch will be polled between 20 and 200. The default value is 200.

174

xStack DGS-3400 Series Fast Ethernet Switch

Packets Statistics

The Web Manager allows various packet statistics to be viewed as either a line graph or a table. Six windows are offered.

Received (RX)

Click the Received (RX) link in the Packets folder of the Monitoring menu to view the following graph of packets received on the Switch. Select the port by using the Port pull down menu. The user may also use the real-time graphic of the Switch and/or switch stack at the top of the web page by simply clicking on a port.

Rx Packets Analysis (line graph for Bytes and Packets)

To view the Received Packets Table, click the link View Table .

175

xStack DGS-3400 Series Fast Ethernet Switch

UMB Cast (RX)

Click the UMB Cast (RX) link in the Packets folder of the Monitoring menu to view the following graph of UMB cast packets received on the Switch. To select a port to view these statistics for, first select the Switch in the switch stack by using the Unit pull-down menu and then select the port by using the Port pull down menu. The user may also use the realtime graphic of the Switch and/or switch stack at the top of the web page by simply clicking on a port.

Figure 10- 5. Packets Analysis (line graph for Unicast, Multicast, and Broadcast Packets)

To view the UMB Cast Table, click the View Table link.

176

xStack DGS-3400 Series Fast Ethernet Switch

Transmitted (TX)

Click the Transmitted (TX) link in the Packets folder of the Monitoring menu to view the following graph of packets transmitted from the Switch. To select a port to view these statistics for, first select the Switch in the switch stack by using the Unit pull-down menu and then select the port by using the Port pull down menu. The user may also use the real-time graphic of the Switch and/or switch stack at the top of the web page by simply clicking on a port.

Figure 10- 6. Tx Packets Analysis window (line graph for Bytes and Packets)

To view the Transmitted (TX) Table, click the link View Table .

Packet Errors

The Web Manager allows port error statistics compiled by the Switch's management agent to be viewed as either a line graph or a table. Four windows are offered.

Received (RX)

Click the Received (RX) link in the Error folder of the Monitoring menu to view the following graph of error packets received on the Switch. To select a port to view these statistics for, first select the Switch in the switch stack by using the

Unit pull-down menu and then select the port by using the Port pull down menu. The user may also use the real-time graphic of the Switch and/or switch stack at the top of the web page by simply clicking on a port.

177

xStack DGS-3400 Series Fast Ethernet Switch

Figure 10- 7. Rx Error Analysis window (line graph)

To view the Received Error Packets Table, click the link View Table, which will show the following table:

178

xStack DGS-3400 Series Fast Ethernet Switch

Transmitted (TX)

Click the Transmitted (TX) link in the Error folder of the Monitoring menu to view the following graph of error packets received on the Switch. To select a port to view these statistics for, first select the Switch in the switch stack by using the

Unit pull-down menu and then select the port by using the Port pull down menu. The user may also use the real-time graphic of the Switch and/or switch stack at the top of the web page by simply clicking on a port.

Figure 10- 8. Tx Error Analysis (line graph)

To view the Transmitted Error Packets Table, click the link View Table , which will show the following table:

179

xStack DGS-3400 Series Fast Ethernet Switch

Packet Size

The Web Manager allows packets received by the Switch, arranged in six groups and classed by size, to be viewed as either a line graph or a table. Two windows are offered. To select a port to view these statistics for, first select the Switch in the switch stack by using the Unit pull-down menu and then select the port by using the Port pull down menu. The user may also use the real-time graphic of the Switch and/or switch stack at the top of the web page by simply clicking on a port.

Figure 10- 9. Rx Size Analysis window (line graph)

To view the Packet Size Analysis Table, click the link View Table , which will show the following table:

180

xStack DGS-3400 Series Fast Ethernet Switch

Browse Router Port

This displays which of the Switch’s ports are currently configured as router ports. A router port configured by a user (using the console or Web-based management interfaces) is displayed as a static router port, designated by S. A router port that is dynamically configured by the Switch is designated by D and a Forbidden port is designated by F.

VLAN Status

Figure 10- 10. Browse Router Port

Figure 10- 11. VLAN Status

181

xStack DGS-3400 Series Fast Ethernet Switch

MAC Address Table

This allows the Switch's dynamic MAC address forwarding table to be viewed. When the Switch learns an association between a MAC address and a port number, it makes an entry into its forwarding table. These entries are then used to forward packets through the Switch.

To view the MAC Address forwarding table, from the Monitoring menu, click the MAC Address link:

Figure 10- 12. MAC Address Table

The functions are used in the MAC address table:

Parameter

VLAN Name

MAC Address

Find

VID

VLAN Name

MAC Address

Port

Type

Next

View All Entry

Delete All Entry

Description

Enter a VLAN Name for the forwarding table to be browsed by.

Enter a MAC address for the forwarding table to be browsed by.

Allows the user to move to a sector of the database corresponding to a user defined port, VLAN, or MAC address.

The VLAN ID of the VLAN of which the port is a member.

The VLAN Name of the VLAN of which the port is a member.

The MAC address entered into the address table.

The port to which the MAC address above corresponds.

Describes the method which the Switch discovered the MAC address. The possible entries are Dynamic, Self, and Static.

Click this button to view the next page of the address table.

Clicking this button will allow the user to view all entries of the address table.

Clicking this button will allow the user to delete all entries of the address table.

182

xStack DGS-3400 Series Fast Ethernet Switch

Switch History Log

The Web manager allows the Switch's history log, as compiled by the Switch's management agent, to be viewed. To view the Switch history log, open the Maintenance folder and click the Switch History Log link.

Figure 10- 13. Switch History Log window

The Switch can record event information in its own logs, to designated SNMP trap receiving stations, and to the PC connected to the console manager. Click Next to go to the next page of the Switch History Log. Clicking Clear will allow the user to clear the Switch History Log.

The information in the table is categorized as:

Parameter

Sequence

Time

Log Text

Description

A counter incremented whenever an entry to the Switch's history log is made. The table displays the last entry (highest sequence number) first.

Displays the time in days, hours, and minutes since the Switch was last restarted.

Displays text describing the event that triggered the history log entry.

183

xStack DGS-3400 Series Fast Ethernet Switch

IGMP Snooping Group

This window allows the Switch’s IGMP Snooping Group Table to be viewed. IGMP Snooping allows the Switch to read the Multicast Group IP address and the corresponding MAC address from IGMP packets that pass through the Switch. The number of IGMP reports that were snooped is displayed in the Reports field.

To view the IGMP Snooping Group Table, click IGMP Snooping Group on the Monitoring menu:

Figure 10- 14. IGMP Snooping Group Table

The user may search the IGMP Snooping Group Table by VID by entering it in the top left hand corner and clicking

Search.

The following field can be viewed:

Parameter

VLAN Name

Multicast Group

MAC Address

Reports

Description

The VLAN ID of the multicast group.

The IP address of the multicast group.

The MAC address of the multicast group.

The total number of reports received for this group.

NOTE: To configure IGMP snooping for the xStack DGS-3400 Series switch, go to the Configuration folder and select IGMP Snooping.

Configuration and other information concerning IGMP snooping may be found in Section 6 of this manual under IGMP Snooping.

184

xStack DGS-3400 Series Fast Ethernet Switch

Port Access Control Information

The following screens are used to monitor 802.1x statistics of the Switch, on a per port basis. To view the Port Access

Control screens, open the monitoring folder and click the Port Access Control folder. There are six screens to monitor.

RADIUS Account Client

This window shows managed objects used for managing RADIUS accounting clients, and the current statistics associated with them. To view the RADIUS Accounting, click Monitoring > Port Access Control > RADIUS Account Client.

Figure 10- 15. RADIUS Account Client information

The user may also select the desired time interval to update the statistics, between 1s and 60s, where “s” stands for seconds. The default value is one second. To clear the current statistics shown, click the Clear button in the top left hand corner.

185

xStack DGS-3400 Series Fast Ethernet Switch

The following information is displayed:

Parameter Description

ClientInvalidServerAddresses The number of RADIUS Accounting-Response packets received from unknown addresses.

ClientIdentifier The NAS-Identifier of the RADIUS accounting client. (This is not necessarily the same as sysName in MIB II.)

ServerIndex

ServerAddress

ServerPortNumber

ClientRoundTripTime

ClientRequests

ClientRetransmissions

ClientResponses

The time interval between the most recent Accounting-Response and the

Accounting-Request that matched it from this RADIUS accounting server.

The number of RADIUS Accounting-Request packets sent. This does not include retransmissions.

The number of RADIUS Accounting-Request packets retransmitted to this

RADIUS accounting server. Retransmissions include retries where the

Identifier and Acct-Delay have been updated, as well as those in which they remain the same.

The number of RADIUS packets received on the accounting port from this server.

ClientMalformedResponses The number of malformed RADIUS Accounting-Response packets received from this server. Malformed packets include packets with an invalid length.

Bad authenticators and unknown types are not included as malformed accounting responses.

ClientBadAuthenticators The number of RADIUS Accounting-Response packets, which contained invalid authenticators, received from this server.

ClientPendingRequests

ClientTimeouts

The number of RADIUS Accounting-Request packets sent to this server that have not yet timed out or received a response. This variable is incremented when an Accounting-Request is sent and decremented due to receipt of an

Accounting-Response, a timeout or a retransmission.

The number of accounting timeouts to this server. After a timeout the client may retry to the same server, send to a different server, or give up. A retry to the same server is counted as a retransmit as well as a timeout. A send to a different server is counted as an Accounting-Request as well as a timeout.

ClientUnknownTypes

ClientPacketsDropped

The identification number assigned to each RADIUS Accounting server that the client shares a secret with.

The (conceptual) table listing the RADIUS accounting servers with which the client shares a secret.

The UDP port the client is using to send requests to this server.

The number of RADIUS packets of unknown type which were received from this server on the accounting port.

The number of RADIUS packets, which were received from this server on the accounting port and dropped for some other reason.

Note: To configure 802.1x features for the xStack switch, go to the

Administration folder and select Port Access Entity.

186

xStack DGS-3400 Series Fast Ethernet Switch

RADIUS Auth Client

This table contains information concerning the activity of the RADIUS authentication client on the client side of the

RADIUS authentication protocol. To view the RADIUS Authentication, click Monitoring > Port Access Control >

RADIUS Auth Client.

Figure 10- 16. RADIUS Authentication information

The user may also select the desired time interval to update the statistics, between 1s and 60s, where “s” stands for seconds. The default value is one second. To clear the current statistics shown, click the Clear button in the top left hand corner.

187

xStack DGS-3400 Series Fast Ethernet Switch

The following information is displayed:

Parameter

InvalidServerAddresses

Identifier

ServerIndex

AuthServerAddress

ServerPortNumber

RoundTripTime

AccessRequests

AccessRetransmissions

AccessAccepts

AccessRejects

AccessChallenges

AccessResponses

BadAuthenticators

PendingRequests

Timeouts

UnknownTypes

PacketsDropped

Description

The number of RADIUS Access-Response packets received from unknown addresses.

The NAS-Identifier of the RADIUS authentication client. (This is not necessarily the same as sysName in MIB II.)

The identification number assigned to each RADIUS Authentication server that the client shares a secret with.

The (conceptual) table listing the RADIUS authentication servers with which the client shares a secret.

The UDP port the client is using to send requests to this server.

The time interval (in hundredths of a second) between the most recent

Access-Reply/Access-Challenge and the Access-Request that matched it from this RADIUS authentication server.

The number of RADIUS Access-Request packets sent to this server. This does not include retransmissions.

The number of RADIUS Access-Request packets retransmitted to this

RADIUS authentication server.

The number of RADIUS Access-Accept packets (valid or invalid) received from this server.

The number of RADIUS Access-Reject packets (valid or invalid) received from this server.

The number of RADIUS Access-Challenge packets (valid or invalid) received from this server.

The number of malformed RADIUS Access-Response packets received from this server. Malformed packets include packets with an invalid length. Bad authenticators or Signature attributes or known types are not included as malformed access responses.

The number of RADIUS Access-Response packets containing invalid authenticators or Signature attributes received from this server.

The number of RADIUS Access-Request packets destined for this server that have not yet timed out or received a response. This variable is incremented when an Access-Request is sent and decremented due to receipt of an

Access-Accept, Access-Reject or Access-Challenge, a timeout or retransmission.

The number of authentication timeouts to this server. After a timeout the client may retry to the same server, send to a different server, or give up. A retry to the same server is counted as a retransmit as well as a timeout. A send to a different server is counted as a Request as well as a timeout.

The number of RADIUS packets of unknown type which were received from this server on the authentication port

The number of RADIUS packets of which were received from this server on the authentication port and dropped for some other reason.

188

xStack DGS-3400 Series Fast Ethernet Switch

Browse ARP Table

The Browse ARP Table window may be found in the Monitoring menu in the Layer 3 Feature folder. This window will show current ARP entries on the Switch. To search a specific ARP entry, enter an interface name into the Interface Name or an IP address and click Find. To clear the ARP Table, click Clear All.

Browse ARP Table window

189

xStack DGS-3400 Series Fast Ethernet Switch

Appendix A

Technical Specifications

Sepecifications listed here apply to all Switches in the DGS-3400 series except where otherwise noted.

General

Standards IEEE 802.3 10BASE-T Ethernet

IEEE 802.3u 100BASE-TX Fast Ethernet

IEEE 802.3ab 1000BASE-T Gigabit Ethernet

IEEE 802.3z 1000BASE-T (SFP “Mini GBIC”)

IEEE 802.3ae (10G Optional Modules)

IEEE 802.1D Spanning Tree

IEEE 802.1W Rapid Spanning Tree

IEEE 802.1 P/Q VLAN

IEEE 802.1p Priority Queues

IEEE 802.3ad Link Aggregation Control

IEEE 802.3x Full-duplex Flow Control

IEEE 802.3 Nway auto-negotiation

IEEE 802.3af Power over Ethernet

CSMA/CD Protocols

Data Transfer Rates:

Ethernet

Fast Ethernet

Gigabit Ethernet

Fiber Optic

Half-duplex Full-duplex

10 Mbps 20Mbps

100Mbps 200Mbps n/a 2000Mbps

SFP (Mini GBIC) Support

IEEE 802.3z 1000BASE-LX (DEM-310GT transceiver)

IEEE 802.3z 1000BASE-SX (DEM-311GT transceiver)

IEEE 802.3z 1000BASE-LH (DEM-314GT transceiver)

IEEE 802.3z 1000BASE-ZX (DEM-315GT transceiver)

Topology

Network Cables

Star

Cat.5 Enhanced for 1000BASE-T

UTP Cat.5, Cat. 5 Enhanced for 100BASE-TX

UTP Cat.3, 4, 5 for 10BASE-T

EIA/TIA-568 100-ohm screened twisted-pair (STP)(100m)

190

Internal power supply

Redundant Power Supply

Power Consumption

DC fans:

Operating Temperature

Storage Temperature

Humidity

Dimensions

Weight

EMI:

Safety: xStack DGS-3400 Series Fast Ethernet Switch

Physical and Environmental

AC Input: 100 - 240 VAC, 50-60 Hz

DGS-3400 Series Switch

DGS-3426 (70.8 Watts)

DGS-3427 (71.6 Watts)

DGS-3450 (131.34 Watts)

12 v fans

0 - 40°C

-40 - 70°C

5 - 95% non-condensing

441mm x 389mm x 44mm

DGS-3400 Series Switch

DGS-3426 (5.42 kg)

DGS-3427 (5.51 kg)

DGS-3450 (5.74 kg)

CE class A, FCC Class A

CSA International, CB Report

Module Inserts

DEM-410CX (0.015 Watts)

DEM-410X (6.16 Watts)

Module Inserts

DEM-410CX (0.16 kg)

DEM-410X (0.18 kg)

Transmission Method

Packet Buffer

Packet Filtering / Forwarding Rate

MAC Address Learning

Priority Queues

Forwarding Table Age Time

Performance

Store-and-forward

0.75 MB per device

Full-wire speed for all connections

1,488,095 pps per port (for 1000Mbps)

Automatic update. Supports 8K MAC address.

8 Priority Queues per port.

Max age: 10-1000000 seconds. Default = 300.

191

xStack DGS-3400 Series Fast Ethernet Switch

Appendix B

Cables and Connectors

When connecting the Switch to another switch, a bridge or hub, a normal cable is necessary. Please review these products for matching cable pin assignment.

The following diagrams and tables show the standard RJ-45 receptacle/connector and their pin assignments.

6

7

4

5

8

2

3

Contact

1

MDI-X Port

RD+ (receive)

RD- (receive)

TD+ (transmit)

Not used

Not used

TD- (transmit)

Not used

Not used

Appendix 1- 1. The standard RJ-45 port and connector

RJ-45 Pin Assignments

MDI-II Port

TD+ (transmit)

TD- (transmit)

RD+ (receive)

Not used

Not used

RD- (receive)

Not used

Not used

Appendix 1- 2. The standard RJ-45 pin assignments

192

xStack DGS-3400 Series Fast Ethernet Switch

Appendix C

100BASE-TX

10BASE-T

Cable Lengths

Use the following table to as a guide for the maximum cable lengths.

Standard

Mini-GBIC

1000BASE-T

Media Type

1000BASE-LX, Single-mode fiber module

1000BASE-SX, Multi-mode fiber module

1000BASE-LHX, Single-mode fiber module

1000BASE-ZX, Single-mode fiber module

Category 5e UTP Cable

Category 5 UTP Cable (1000 Mbps)

Category 5 UTP Cable (100 Mbps)

Category 3 UTP Cable (10 Mbps)

Maximum Distance

10km

550m

40km

80km

100m

100m

100m

193

Glossary

1000BASE-LX: A short laser wavelength on multimode fiber optic cable for a maximum length of 550 meters

1000BASE-SX: A long wavelength for a "long haul" fiber optic cable for a maximum length of 10 kilometers

100BASE-FX: 100Mbps Ethernet implementation over fiber.

100BASE-TX: 100Mbps Ethernet implementation over Category 5 and Type 1 Twisted Pair cabling.

10BASE-T: The IEEE 802.3 specification for Ethernet over Unshielded Twisted Pair (UTP) cabling.

ageing: The automatic removal of dynamic entries from the Switch Database which have timed-out and are no longer valid.

ATM: Asynchronous Transfer Mode. A connection oriented transmission protocol based on fixed length cells (packets). ATM is designed to carry a complete range of user traffic, including voice, data and video signals.

auto-negotiation: A feature on a port which allows it to advertise its capabilities for speed, duplex and flow control. When connected to an end station that also supports auto-negotiation, the link can self-detect its optimum operating setup.

backbone port: A port which does not learn device addresses, and which receives all frames with an unknown address. Backbone ports are normally used to connect the Switch to the backbone of your network. Note that backbone ports were formerly known as designated downlink ports.

backbone: The part of a network used as the primary path for transporting traffic between network segments.

bandwidth: Information capacity, measured in bits per second, that a channel can transmit. The bandwidth of Ethernet is 10Mbps, the bandwidth of Fast Ethernet is 100Mbps.

baud rate: The switching speed of a line. Also known as line speed between network segments.

BOOTP: The BOOTP protocol allows automatic mapping of an IP address to a given MAC address each time a device is started.

In addition, the protocol can assign the subnet mask and default gateway to a device.

bridge: A device that interconnects local or remote networks no matter what higher level protocols are involved. Bridges form a single logical network, centralizing network administration.

broadcast: A message sent to all destination devices on the network.

broadcast storm: Multiple simultaneous broadcasts that typically absorb available network bandwidth and can cause network failure.

console port: The port on the Switch accepting a terminal or modem connector. It changes the parallel arrangement of data within computers to the serial form used on data transmission links. This port is most often used for dedicated local management.

CSMA/CD: Channel access method used by Ethernet and IEEE 802.3 standards in which devices transmit only after finding the data channel clear for some period of time. When two devices transmit simultaneously, a collision occurs and the colliding devices delay their retransmissions for a random amount of time.

data center switching: The point of aggregation within a corporate network where a switch provides high-performance access to server farms, a high-speed backbone connection and a control point for network management and security.

Ethernet: A LAN specification developed jointly by Xerox, Intel and Digital Equipment Corporation. Ethernet networks operate at 10Mbps using CSMA/CD to run over cabling.

Fast Ethernet: 100Mbps technology based on the Ethernet/CD network access method.

Flow Control: (IEEE 802.3z) A means of holding packets back at the transmit port of the connected end station. Prevents packet loss at a congested switch port.

forwarding: The process of sending a packet toward its destination by an internetworking device.

full duplex: A system that allows packets to be transmitted and received at the same time and, in effect, doubles the potential throughput of a link.

half duplex: A system that allows packets to be transmitted and received, but not at the same time. Contrast with full duplex.

IP address: Internet Protocol address. A unique identifier for a device attached to a network using TCP/IP. The address is written as four octets separated with full-stops (periods), and is made up of a network section, an optional subnet section and a host section.

IPX: Internetwork Packet Exchange. A protocol allowing communication in a NetWare network.

194

LAN - Local Area Network: A network of connected computing resources (such as PCs, printers, servers) covering a relatively small geographic area (usually not larger than a floor or building). Characterized by high data rates and low error rates.

latency: The delay between the time a device receives a packet and the time the packet is forwarded out of the destination port.

line speed: See baud rate.

main port: The port in a resilient link that carries data traffic in normal operating conditions.

MDI - Medium Dependent Interface: An Ethernet port connection where the transmitter of one device is connected to the receiver of another device.

MDI-X - Medium Dependent Interface Cross-over: An Ethernet port connection where the internal transmit and receive lines are crossed.

MIB - Management Information Base: Stores a device's management characteristics and parameters. MIBs are used by the

Simple Network Management Protocol (SNMP) to contain attributes of their managed systems. The Switch contains its own internal MIB.

multicast: Single packets copied to a specific subset of network addresses. These addresses are specified in the destinationaddress field of the packet.

protocol: A set of rules for communication between devices on a network. The rules dictate format, timing, sequencing and error control.

resilient link: A pair of ports that can be configured so that one will take over data transmission should the other fail. See also main port and standby port.

RJ-45: Standard 8-wire connectors for IEEE 802.3 10BASE-T networks.

RMON: Remote Monitoring. A subset of SNMP MIB II that allows monitoring and management capabilities by addressing up to ten different groups of information.

RPS - Redundant Power System: A device that provides a backup source of power when connected to the Switch.

server farm: A cluster of servers in a centralized location serving a large user population.

SLIP - Serial Line Internet Protocol: A protocol which allows IP to run over a serial line connection.

SNMP - Simple Network Management Protocol: A protocol originally designed to be used in managing TCP/IP internets.

SNMP is presently implemented on a wide range of computers and networking equipment and may be used to manage many aspects of network and end station operation.

Spanning Tree Protocol (STP): A bridge-based system for providing fault tolerance on networks. STP works by allowing the user to implement parallel paths for network traffic, and ensure that redundant paths are disabled when the main paths are operational and enabled if the main paths fail.

STACK: A group of network devices that are integrated to form a single logical device.

standby port: The port in a resilient link that will take over data transmission if the main port in the link fails.

switch: A device which filters, forwards and floods packets based on the packet's destination address. The switch learns the addresses associated with each switch port and builds tables based on this information to be used for the switching decision.

TCP/IP: A layered set of communications protocols providing Telnet terminal emulation, FTP file transfer, and other services for communication among a wide range of computer equipment.

telnet: A TCP/IP application protocol that provides virtual terminal service, letting a user log in to another computer system and access a host as if the user were connected directly to the host.

TFTP - Trivial File Transfer Protocol: Allows the user to transfer files (such as software upgrades) from a remote device using your switch's local management capabilities.

UDP - User Datagram Protocol: An Internet standard protocol that allows an application program on one device to send a datagram to an application program on another device.

VLAN - Virtual LAN: A group of location- and topology-independent devices that communicate as if they are on a common physical LAN.

VLT - Virtual LAN Trunk: A Switch-to-Switch link which carries traffic for all the VLANs on each Switch.

VT100: A type of terminal that uses ASCII characters. VT100 screens have a text-based appearance.

195

Warrenties/Registration

LIMITED WARRANTY

D-Link provides this limited warranty for its product only to the person or entity who originally purchased the product from D-

Link or its authorized reseller or distributor. D-Link would fulfill the warranty obligation according to the local warranty policy in which you purchased our products.

Limited Hardware Warranty: D-Link warrants that the hardware portion of the D-Link products described below (“Hardware”) will be free from material defects in workmanship and materials from the date of original retail purchase of the Hardware, for the period set forth below applicable to the product type (“Warranty Period”) if the Hardware is used and serviced in accordance with applicable documentation; provided that a completed Registration Card is returned to an Authorized D-Link Service Office within ninety (90) days after the date of original retail purchase of the Hardware. If a completed Registration Card is not received by an authorized D-Link Service Office within such ninety (90) period, then the Warranty Period shall be ninety (90) days from the date of purchase.

Product Type

Product (including Power Supplies and Fans)

Spare parts and pare kits

Warranty Period

One (1) Year

Ninety (90) days

D-Link’s sole obligation shall be to repair or replace the defective Hardware at no charge to the original owner. Such repair or replacement will be rendered by D-Link at an Authorized D-Link Service Office. The replacement Hardware need not be new or of an identical make, model or part; D-Link may in its discretion may replace the defective Hardware (or any part thereof) with any reconditioned product that D-Link reasonably determines is substantially equivalent (or superior) in all material respects to the defective Hardware. The Warranty Period shall extend for an additional ninety (90) days after any repaired or replaced

Hardware is delivered. If a material defect is incapable of correction, or if D-Link determines in its sole discretion that it is not practical to repair or replace the defective Hardware, the price paid by the original purchaser for the defective Hardware will be refunded by D-Link upon return to D-Link of the defective Hardware. All Hardware (or part thereof) that is replaced by D-Link, or for which the purchase price is refunded, shall become the property of D-Link upon replacement or refund.

Limited Software Warranty: D-Link warrants that the software portion of the product (“Software”) will substantially conform to

D-Link’s then current functional specifications for the Software, as set forth in the applicable documentation, from the date of original delivery of the Software for a period of ninety (90) days (“Warranty Period”), if the Software is properly installed on approved hardware and operated as contemplated in its documentation. D-Link further warrants that, during the Warranty Period, the magnetic media on which D-Link delivers the Software will be free of physical defects. D-Link’s sole obligation shall be to replace the non-conforming Software (or defective media) with software that substantially conforms to D-Link’s functional specifications for the Software. Except as otherwise agreed by D-Link in writing, the replacement Software is provided only to the original licensee, and is subject to the terms and conditions of the license granted by D-Link for the Software. The Warranty

Period shall extend for an additional ninety (90) days after any replacement Software is delivered. If a material non-conformance is incapable of correction, or if D-Link determines in its sole discretion that it is not practical to replace the non-conforming

Software, the price paid by the original licensee for the non-conforming Software will be refunded by D-Link; provided that the non-conforming Software (and all copies thereof) is first returned to D-Link. The license granted respecting any Software for which a refund is given automatically terminates.

What You Must Do For Warranty Service:

Registration Card. The Registration Card provided at the back of this manual must be completed and returned to an Authorized D-

Link Service Office for each D-Link product within ninety (90) days after the product is purchased and/or licensed. The

196

addresses/telephone/fax list of the nearest Authorized D-Link Service Office is provided in the back of this manual. FAILURE TO

PROPERLY COMPLETE AND TIMELY RETURN THE REGISTRATION CARD MAY AFFECT THE WARRANTY FOR

THIS PRODUCT.

Submitting A Claim. Any claim under this limited warranty must be submitted in writing before the end of the Warranty Period to an Authorized D-Link Service Office. The claim must include a written description of the Hardware defect or Software nonconformance in sufficient detail to allow D-Link to confirm the same. The original product owner must obtain a Return

Material Authorization (RMA) number from the Authorized D-Link Service Office and, if requested, provide written proof of purchase of the product (such as a copy of the dated purchase invoice for the product) before the warranty service is provided.

After an RMA number is issued, the defective product must be packaged securely in the original or other suitable shipping package to ensure that it will not be damaged in transit, and the RMA number must be prominently marked on the outside of the package. The packaged product shall be insured and shipped to Authorized D-Link Service Office with all shipping costs prepaid.

D-Link may reject or return any product that is not packaged and shipped in strict compliance with the foregoing requirements, or for which an RMA number is not visible from the outside of the package. The product owner agrees to pay D-Link’s reasonable handling and return shipping charges for any product that is not packaged and shipped in accordance with the foregoing requirements, or that is determined by D-Link not to be defective or non-conforming.

What Is Not Covered:

This limited warranty provided by D-Link does not cover:

Products that have been subjected to abuse, accident, alteration, modification, tampering, negligence, misuse, faulty installation, lack of reasonable care, repair or service in any way that is not contemplated in the documentation for the product, or if the model or serial number has been altered, tampered with, defaced or removed;

Initial installation, installation and removal of the product for repair, and shipping costs;

Operational adjustments covered in the operating manual for the product, and normal maintenance;

Damage that occurs in shipment, due to act of God, failures due to power surge, and cosmetic damage; and Any hardware, software, firmware or other products or services provided by anyone other than D-Link.

Disclaimer of Other Warranties: EXCEPT FOR THE LIMITED WARRANTY SPECIFIED HEREIN, THE PRODUCT IS

PROVIDED “AS-IS” WITHOUT ANY WARRANTY OF ANY KIND INCLUDING, WITHOUT LIMITATION, ANY

WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT. IF

ANY IMPLIED WARRANTY CANNOT BE DISCLAIMED IN ANY TERRITORY WHERE A PRODUCT IS SOLD, THE

DURATION OF SUCH IMPLIED WARRANTY SHALL BE LIMITED TO NINETY (90) DAYS. EXCEPT AS EXPRESSLY

COVERED UNDER THE LIMITED WARRANTY PROVIDED HEREIN, THE ENTIRE RISK AS TO THE QUALITY,

SELECTION AND PERFORMANCE OF THE PRODUCT IS WITH THE PURCHASER OF THE PRODUCT.

Limitation of Liability: TO THE MAXIMUM EXTENT PERMITTED BY LAW, D-LINK IS NOT LIABLE UNDER ANY

CONTRACT, NEGLIGENCE, STRICT LIABILITY OR OTHER LEGAL OR EQUITABLE THEORY FOR ANY LOSS OF

USE OF THE PRODUCT, INCONVENIENCE OR DAMAGES OF ANY CHARACTER, WHETHER DIRECT, SPECIAL,

INCIDENTAL OR CONSEQUENTIAL (INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS OF GOODWILL,

WORK STOPPAGE, COMPUTER FAILURE OR MALFUNCTION, LOSS OF INFORMATION OR DATA CONTAINED IN,

STORED ON, OR INTEGRATED WITH ANY PRODUCT RETURNED TO D-LINK FOR WARRANTY SERVICE)

RESULTING FROM THE USE OF THE PRODUCT, RELATING TO WARRANTY SERVICE, OR ARISING OUT OF ANY

BREACH OF THIS LIMITED WARRANTY, EVEN IF D-LINK HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH

DAMAGES. THE SOLE REMEDY FOR A BREACH OF THE FOREGOING LIMITED WARRANTY IS REPAIR,

REPLACEMENT OR REFUND OF THE DEFECTIVE OR NON-CONFORMING PRODUCT.

197

GOVERNING LAW: This Limited Warranty shall be governed by the laws of the state of California.

Some states do not allow exclusion or limitation of incidental or consequential damages, or limitations on how long an implied warranty lasts, so the foregoing limitations and exclusions may not apply. This limited warranty provides specific legal rights and the product owner may also have other rights which vary from state to state.

Trademarks

Copyright .2002 D-Link Corporation. Contents subject to change without prior notice. D-Link is a registered trademark of D-Link

Corporation/D-Link Systems, Inc. All other trademarks belong to their respective proprietors.

Copyright Statement

No part of this publication may be reproduced in any form or by any means or used to make any derivative such as translation, transformation, or adaptation without permission from D-Link Corporation/D-Link Systems Inc., as stipulated by the United

States Copyright Act of 1976.

FCC Warning

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC

Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this manual, may cause harmful interfe rence to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

198

Subject to the terms and conditions set forth herein, D-Link Systems, Inc. (“D-Link”) provides this Limited Warranty:

Only to the person or entity that originally purchased the product from D-Link or its authorized reseller or distributor, and

Only for products purchased and delivered within the fifty states of the United States, the District of Columbia, U.S. Possessions or

Protectorates, U.S. Military Installations, or addresses with an APO or FPO.

Limited Warranty: D-Link warrants that the hardware portion of the D-Link product described below (“Hardware”) will be free from material defects in workmanship and materials under normal use from the date of original retail purchase of the product, for the period set forth below (“Warranty

Period”), except as otherwise stated herein.

• Hardware (excluding power supplies and fans): Five (5) Years

• Power supplies and fans: One (1) Year

• Spare parts and spare kits: Ninety (90) days

The customer's sole and exclusive remedy and the entire liability of D-Link and its suppliers under this Limited Warranty will be, at D-Link’s option, to repair or replace the defective Hardware during the Warranty Period at no charge to the original owner or to refund the actual purchase price paid. Any repair or replacement will be rendered by D-Link at an Authorized D-Link Service Office. The replacement hardware need not be new or have an identical make, model or part. D-Link may, at its option, replace the defective Hardware or any part thereof with any reconditioned product that D-Link reasonably determines is substantially equivalent (or superior) in all material respects to the defective Hardware. Repaired or replacement hardware will be warranted for the remainder of the original Warranty Period or ninety (90) days, whichever is longer, and is subject to the same limitations and exclusions. If a material defect is incapable of correction, or if D-Link determines that it is not practical to repair or replace the defective Hardware, the actual price paid by the original purchaser for the defective Hardware will be refunded by D-Link upon return to D-Link of the defective Hardware. All

Hardware or part thereof that is replaced by D-Link, or for which the purchase price is refunded, shall become the property of D-Link upon replacement or refund.

Limited Software Warranty: D-Link warrants that the software portion of the product (“Software”) will substantially conform to D-Link’s then current functional specifications for the Software, as set forth in the applicable documentation, from the date of original retail purchase of the Software for a period of ninety (90) days (“Software Warranty Period”), provided that the Software is properly installed on approved hardware and operated as contemplated in its documentation. D-Link further warrants that, during the Software Warranty Period, the magnetic media on which D-Link delivers the

Software will be free of physical defects. The customer's sole and exclusive remedy and the entire liability of D-Link and its suppliers under this Limited

Warranty will be, at D-Link’s option, to replace the non-conforming Software (or defective media) with software that substantially conforms to D-Link’s functional specifications for the Software or to refund the portion of the actual purchase price paid that is attributable to the Software. Except as otherwise agreed by D-Link in writing, the replacement Software is provided only to the original licensee, and is subject to the terms and conditions of the license granted by D-Link for the Software. Replacement Software will be warranted for the remainder of the original Warranty Period and is subject to the same limitations and exclusions. If a material non-conformance is incapable of correction, or if D-Link determines in its sole discretion that it is not practical to replace the non-conforming Software, the price paid by the original licensee for the non-conforming Software will be refunded by D-Link; provided that the non-conforming Software (and all copies thereof) is first returned to D-Link. The license granted respecting any Software for which a refund is given automatically terminates.

Non-Applicability of Warranty: The Limited Warranty provided hereunder for Hardware and Software portions of D-Link's products will not be applied to and does not cover any refurbished product and any product purchased through the inventory clearance or liquidation sale or other sales in which D-Link, the sellers, or the liquidators expressly disclaim their warranty obligation pertaining to the product and in that case, the product is being sold "As-Is" without any warranty whatsoever including, without limitation, the Limited Warranty as described herein, notwithstanding anything stated herein to the contrary.

Submitting A Claim: The customer shall return the product to the original purchase point based on its return policy. In case the return policy period has expired and the product is within warranty, the customer shall submit a claim to D-Link as outlined below:

• The customer must submit with the product as part of the claim a written description of the Hardware defect or Software nonconformance in sufficient detail to allow D-Link to confirm the same, along with proof of purchase of the product (such as a copy of the dated purchase invoice for the product) if the product is not registered.

• The customer must obtain a Case ID Number from D-Link Technical Support at 1-877-453-5465, who will attempt to assist the customer in resolving any suspected defects with the product. If the product is considered defective, the customer must obtain a Return Material

Authorization (“RMA”) number by completing the RMA form and entering the assigned Case ID Number at https://rma.dlink.com/ .

• After an RMA number is issued, the defective product must be packaged securely in the original or other suitable shipping package to ensure that it will not be damaged in transit, and the RMA number must be prominently marked on the outside of the package. Do not include any manuals or accessories in the shipping package. D-Link will only replace the defective portion of the product and will not ship back any accessories.

• The customer is responsible for all in-bound shipping charges to D-Link. No Cash on Delivery (“COD”) is allowed. Products sent COD will either be rejected by D-Link or become the property of D-Link. Products shall be fully insured by the customer and shipped to D-Link

Systems, Inc., 17595 Mt. Herrmann, Fountain Valley, CA 92708. D-Link will not be held responsible for any packages that are lost in transit to D-Link. The repaired or replaced packages will be shipped to the customer via UPS Ground or any common carrier selected by D-

Link. Return shipping charges shall be prepaid by D-Link if you use an address in the United States, otherwise we will ship the product to you freight collect. Expedited shipping is available upon request and provided shipping charges are prepaid by the customer.

D-Link may reject or return any product that is not packaged and shipped in strict compliance with the foregoing requirements, or for which an RMA number is not visible from the outside of the package. The product owner agrees to pay D-Link’s reasonable handling and return shipping charges for any product that is not packaged and shipped in accordance with the foregoing requirements, or that is determined by D-Link not to be defective or nonconforming.

What Is Not Covered: The Limited Warranty provided herein by D-Link does not cover: Products that, in D-Link’s judgment, have been subjected to abuse, accident, alteration, modification, tampering, negligence, misuse, faulty installation, lack of reasonable care, repair or service in any way that is not contemplated in the documentation for the product, or if the model or serial number has been altered, tampered with, defaced or removed; Initial installation, installation and removal of the product for repair, and shipping costs; Operational adjustments covered in the operating manual for the product, and normal maintenance; Damage that occurs in shipment, due to act of God, failures due to power surge, and cosmetic damage; Any hardware, software, firmware or other products or services provided by anyone other than D-Link; and Products that have been purchased from inventory clearance or liquidation sales or other sales in which D-Link, the sellers, or the liquidators expressly disclaim their warranty obligation pertaining to the product.

While necessary maintenance or repairs on your Product can be performed by any company, we recommend that you use only an Authorized D-Link

Service Office. Improper or incorrectly performed maintenance or repair voids this Limited Warranty.

Disclaimer of Other Warranties: EXCEPT FOR THE LIMITED WARRANTY SPECIFIED HEREIN, THE PRODUCT IS PROVIDED “AS-IS”

WITHOUT ANY WARRANTY OF ANY KIND WHATSOEVER INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF

MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT. IF ANY IMPLIED WARRANTY CANNOT BE

199

DISCLAIMED IN ANY TERRITORY WHERE A PRODUCT IS SOLD, THE DURATION OF SUCH IMPLIED WARRANTY SHALL BE LIMITED

TO THE DURATION OF THE APPLICABLE WARRANTY PERIOD SET FORTH ABOVE. EXCEPT AS EXPRESSLY COVERED UNDER THE

LIMITED WARRANTY PROVIDED HEREIN, THE ENTIRE RISK AS TO THE QUALITY, SELECTION AND PERFORMANCE OF THE

PRODUCT IS WITH THE PURCHASER OF THE PRODUCT.

Limitation of Liability: TO THE MAXIMUM EXTENT PERMITTED BY LAW, D-LINK IS NOT LIABLE UNDER ANY CONTRACT,

NEGLIGENCE, STRICT LIABILITY OR OTHER LEGAL OR EQUITABLE THEORY FOR ANY LOSS OF USE OF THE PRODUCT,

INCONVENIENCE OR DAMAGES OF ANY CHARACTER, WHETHER DIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL

(INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS OF GOODWILL, LOSS OF REVENUE OR PROFIT, WORK STOPPAGE,

COMPUTER FAILURE OR MALFUNCTION, FAILURE OF OTHER EQUIPMENT OR COMPUTER PROGRAMS TO WHICH D-LINK’S

PRODUCT IS CONNECTED WITH, LOSS OF INFORMATION OR DATA CONTAINED IN, STORED ON, OR INTEGRATED WITH ANY

PRODUCT RETURNED TO D-LINK FOR WARRANTY SERVICE) RESULTING FROM THE USE OF THE PRODUCT, RELATING TO

WARRANTY SERVICE, OR ARISING OUT OF ANY BREACH OF THIS LIMITED WARRANTY, EVEN IF D-LINK HAS BEEN ADVISED OF

THE POSSIBILITY OF SUCH DAMAGES. THE SOLE REMEDY FOR A BREACH OF THE FOREGOING LIMITED WARRANTY IS REPAIR,

REPLACEMENT OR REFUND OF THE DEFECTIVE OR NON-CONFORMING PRODUCT. THE MAXIMUM LIABILITY OF D-LINK UNDER

THIS WARRANTY IS LIMITED TO THE PURCHASE PRICE OF THE PRODUCT COVERED BY THE WARRANTY. THE FOREGOING

EXPRESS WRITTEN WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ANY OTHER WARRANTIES OR REMEDIES,

EXPRESS, IMPLIED OR STATUTORY.

Governing Law: This Limited Warranty shall be governed by the laws of the State of California. Some states do not allow exclusion or limitation of incidental or consequential damages, or limitations on how long an implied warranty lasts, so the foregoing limitations and exclusions may not apply.

This Limited Warranty provides specific legal rights and you may also have other rights which vary from state to state.

Trademarks: D-Link is a registered trademark of D-Link Systems, Inc. Other trademarks or registered trademarks are the property of their respective owners.

Copyright Statement: No part of this publication or documentation accompanying this product may be reproduced in any form or by any means or used to make any derivative such as translation, transformation, or adaptation without permission from D-Link Corporation/D-Link Systems, Inc., as stipulated by the United States Copyright Act of 1976 and any amendments thereto. Contents are subject to change without prior notice. Copyright 2004 by D-Link Corporation/D-Link Systems, Inc. All rights reserved.

CE Mark Warning: This is a Class A product. In a residential environment, this product may cause radio interference, in which case the user may be required to take adequate measures.

FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC

Rules. These limits are designed to provide reasonable protection against harmful interference in a commercial installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communication. However, there is no guarantee that interference will not occur in a particular installation. Operation of this equipment in a residential environment is likely to cause harmful interference to radio or television reception. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and receiver.

• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.

For detailed warranty information applicable to products purchased outside the United States, please contact the corresponding local D-Link office.

200

Product Registration:

Register online your D-Link product at http://support.dlink.com/register/

Product registration is entirely voluntary and failure to complete or return this form will not

diminish your warranty rights.

201

202

D-Link Europe Limited Lifetime Warranty

Dear Customer, please read below to understand the details of the warranty coverage you have.

Warranty terms for D-LINK xStack products:

All D-Link xStack products* are supplied with a 5 year warranty as standard. To enable the

Limited Lifetime Warranty on this product you must register the product, within the first three months of purchase**, on the following website: http://www.dlink.biz/productregistration/

D-Link will then provide you with a Limited Lifetime Warranty reference number for this product. Please retain your original dated proof of purchase with a note of the serial number, and Limited Lifetime Warranty reference number together with this warranty statement and place each document in a safe location. When you make a warranty claim on a defective product, you may be asked to provide this information.

Nothing in this Limited Lifetime Warranty affects your statutory rights as a consumer. The following are special terms applicable to your Limited Lifetime hardware warranty.

Warranty beneficiary

The warranty beneficiary is the original end user. The original end user is defined as the person that purchases the product as the first owner.

Duration of Limited Lifetime Warranty

As long as the original end-user continues to own or use the product with the following conditions:

- fan and power supplies are limited to a five (5) year warranty only

- in the event of discontinuance of product manufacture, D-Link warranty support is limited to five (5) years from the announcement of discontinuance. If a product is no longer available for replacement, D-Link will issue a product comparable or better to the one originally purchased.

Replacement, Repair or Refund Procedure for Hardware

D-Link or its service center will use commercially reasonable efforts to ship a replacement part within ten (10) working days after receipt of the RMA request. Actual delivery times may vary depending on customer location. D-Link reserves the right to refund the purchase price as its exclusive warranty remedy.

2

203

To Receive a Return Materials Authorization (RMA) Number, please visit: http://service.dlink.biz

and for Italy and Spain, please use: http://rma.dlink.es

or http://rma.dlink.it

.

D-Link Limited Lifetime Warranty

Hardware: D-Link warrants the D-Link hardware named above against defects in materials and workmanship for the period specified above. If D-Link receives notice of such defects during the warranty period, D-Link will, at its option, either repair or replace products proving to be defective. Replacement products may be either new or like-new.

Software. D-Link warrants that D-Link software will not fail to execute its programming instructions, for the period specified above, due to defects in material and workmanship when properly installed and used. If D-Link receives notice of such defects during the warranty period,

D-Link will replace software media that does not execute its programming instructions due to such defects.

Warranty exclusions

This warranty does not apply if the software, product or any other equipment upon which the software is authorized to be used (a) has been altered, except by D-Link or its authorized representative, (b) has not been installed, operated, repaired, or maintained in accordance with instructions supplied by D-Link (improper use or improper maintenance), (c) has been subjected to abnormal physical or electrical stress, misuse, negligence, or accident; (d) is licensed, for beta, evaluation, testing or demonstration purposes for which D-Link does not charge a purchase price or license fee or (e) defects are caused by force majeure (lightning, floods, war, etc.), soiling, by extraordinary environmental influences or by other circumstances of which D-Link is not responsible.

Disclaimer of warranty

Please note, some countries do not allow the disclaimer of implied terms in contracts with consumers and the disclaimer below may not apply to you.

To the extend allowed by local law, the above warranties are exclusive and no other warranty, condition or other term, whether written or oral, is expressed or implied. D-Link specifically disclaims any implied warranties, conditions and terms of merchantability, satisfactory quality, and fitness for a particular purpose.

To the extent allowed by local law, the remedies in this warranty statement are customer’s sole and exclusive remedies. Except as indicated above, in no event will D-Link or its suppliers be liable for loss of data or for indirect, special, incidental, consequential (including lost profit or data), or other damage, whether based in a contract, tort, or otherwise.

To the extent local law mandatorily requires a definition of “Lifetime Warranty” different from that provided here, then the local law definition will supersede and take precedence.

204

Valid law

The warranty is subject to the valid laws in the country of purchase and is to be interpreted in the warranty terms with the said laws. You may have additional legal rights that are not restricted by this warranty. Nothing in this Limited Lifetime Warranty affects your statutory rights as a consumer.

* DES-6500 series is excluded from the Limited Lifetime Warranty offering and will be supplied with a standard 5 year warranty.

** Failure to register this product within the first three months of purchase [by the first user only] will invalidate the Limited Lifetime Warranty.

205

Tech Support

Technical Support

You can find software updates and user documentation on the

D-Link website.

Tech Support for customers within Australia:

D-Link Technical Support over the Telephone:

1300-766-868

Monday to Friday 8:00am to 8:00pm EST

Saturday 9:00am to 1:00pm EST

D-Link Technical Support over the Internet: http://www.dlink.com.au email:[email protected]

Tech Support for customers within New Zealand:

D-Link Technical Support over the Telephone:

0800-900-900

Monday to Friday 8:30am to 8:30pm

Saturday 9:00am to 5:00pm

206

Technical Support

You can find software updates and user documentation on the D-Link website.

Tech Support for customers within South Eastern

Asia and Korea:

D-Link South Eastern Asia and Korea Technical

Support over the Telephone:

+65-6895-5355

Monday to Friday 9:00am to 12:30pm, 2:00pm-6:00pm

Singapore Time

D-Link Technical Support over the Internet: email:[email protected]

207

Technical Support

You can find software updates and user documentation on the

D-Link website.

Tech Support for customers within India

D-Link Technical Support over the Telephone:

+91-22-26526741

+91-22-26526696 –ext 161 to 167

Monday to Friday 9:30AM to 7:00PM

D-Link Technical Support over the Internet: http://ww.dlink.co.in http://www.dlink.co.in/dlink/drivers/support.asp

208

Technical Support

You can find software updates and user documentation on the D-Link website.

D-Link provides free technical support for customers for the duration of the warranty period on this product.

Customers can contact D-Link technical support through our web site or by phone.

Tech Support for customers within the Russia

D-Link Technical Support over the Telephone:

(095) 744-00-99

Monday to Friday 10:00am to 6:30pm

209

Technical Support

You can find software updates and user documentation on the D-Link website.

Tech Support for customers within the U.A.E & North Africa:

D-Link Technical Support over the Telephone:

(971) 4-391-6480 (U.A.E)

Sunday to Wednesday 9:00am to 6:00pm GMT+4

Thursday 9:00am to 1:00pm GMT+4

D-Link Middle East & North Africa

D-Link Technical Support over the Internet: http://support.dlink-me.com

email:[email protected]

Tech Support for customers within Israel:

D-Link Technical Support over the Telephone:

(972) 971-5701

Sunday to Thursday 9:00am to 5:00pm

D-Link Technical Support over the Internet: http://www.dlink.co.il/forum e-mail: [email protected]

Tech Support for customers within Turkey:

D-Link Technical Support over the Telephone:

(+90) 212-289 56 59

Monday to Friday 9:00am to 6:00pm

D-Link Technical Support over the Internet: http://www.dlink.com.tr e-mail: [email protected]

Tech Support for customers within Egypt:

D-Link Technical Support over the Telephone:

(202) 414-4295

Sunday to Thursday 9:00am to 5:00pm

D-Link Technical Support over the Internet: http://support dlink-me com

210

Technical Support

You can find software updates and user documentation on the D-Link website.

Tech Support for customers within South Africa and

Sub Sahara Region:

D-Link South Africa and Sub Sahara Technical Support over the Telephone:

+27-12-665-2165

08600 DLINK ( For South Africa only )

Monday to Friday 8:30am to 9:00pm South Africa Time

D-Link Technical Support over the Internet: http://www.d-link.co.za email:[email protected]

211

Technical Support

You can find updates and user documentation on the D-Link website

Tech Support for Latin America customers:

D-Link Technical Support over the followings Telephones:

Argentina: 0800-666 1442 Monday to Friday 09:00am to 22:00pm

Chile: 800-214 422 Monday to Friday 08:00am to 21:00pm

Colombia: 01800-700 1588 Monday to Friday 07:00am to 20:00pm

Ecuador: 1800-777 711 Monday to Friday 07:00am to 20:00pm

El Salvador: 800-6137 Monday to Friday 06:00am to 19:00pm

Guatemala:1800-300 0017 Monday to Friday 06:00am to 19:00pm

Panama: 0800-560 0193 Monday to Friday 07:00am to 20:00pm

Peru: 0800-52049 Monday to Friday 07:00am to 20:00pm

Venezuela: 0800-100 3470 Monday to Friday 08:00am to 21:00pm

D-Link Technical Support over the Internet: www.dlinkla.com www.dlinklatinamerica.com email:[email protected]

Tech Support for customers within Brazil:

212

Техническая поддержка

Обновления программного обеспечения и документация доступны на Интернет-сайте D-Link.

D-Link предоставляет бесплатную поддержку для клиентов в течение гарантийного срока.

Клиенты могут обратиться в группу технической поддержки

D-Link по телефону или через Интернет.

Техническая поддержка D-Link:

(095) 744-00-99

Техническая поддержка через Интернет http://www.dlink.ru email: [email protected]

213

Asistencia Técnica

D-Link Latin América pone a disposición de sus clientes, especificaciones, documentación y software mas reciente a través de nuestro Sitio Web

www.dlinklatinamerica.com

El servicio de soporte técnico tiene presencia en numerosos países de la

Región Latino América, y presta asistencia gratuita a todos los clientes de

D-Link, en forma telefónica e internet, a través de la casilla [email protected]

Soporte Técnico Help Desk Argentina:

Teléfono: 0800-6661442 Lunes a Viernes 09:00 am a 22:00 pm

Soporte Técnico Help Desk Chile:

Teléfono: 800-214422 Lunes a Viernes 08:00 am a 21:00 pm

Soporte Técnico Help Desk Colombia:

Teléfono: 01800-7001588 Lunes a Viernes 07:00 am a 20:00 pm

Soporte Técnico Help Desk Ecuador:

Teléfono: 1800-777 711 Lunes a Viernes 07:00 am a 20:00 pm

Soporte Técnico Help Desk El Salvador:

Teléfono: 800-6137 Lunes a Viernes 06:00 am a 19:00 pm

Soporte Técnico Help Desk Guatemala:

Teléfono: 1800-300 0017 Lunes a Viernes 06:00 am a 19:00 pm

Soporte Técnico Help Desk Panamá:

Teléfono: 0800-560 0193 Lunes a Viernes 07:00 am a 20:00 pm

Soporte Técnico Help Desk Perú:

Teléfono: 0800-52049 Lunes a Viernes 07:00 am a 20:00 pm

Soporte Técnico Help Desk Venezuela:

Teléfono: 0800-1003470 Lunes a Viernes 08:00 am a 21:00 pm

214

Suporte Técnico

Você pode encontrar atualizações de software e documentação de usuário no site da D-Link Brasil www.dlinkbrasil.com.br.

A D-Link fornece suporte técnico gratuito para clientes no

Brasil durante o período de vigência da garantia deste produto.

Suporte Técnico para clientes no Brasil:

Telefone

São Paulo (11) 2185-9301

Segunda à sexta

Das 8h30 às 18h30

Demais Regiões do Brasil 0800 70 14 104

E-mail:

email:[email protected]

215

216

Technical Support

You can find software updates and user documentation on the D-Link website.

D-Link provides free technical support for customers within the United

States and within Canada for the duration of the warranty period on this product.

U.S. and Canadian customers can contact D-Link technical support through our website, or by phone.

Tech Support for customers within the United States:

D-Link Technical Support over the Telephone:

(888) 843-6100

Hours of Operation: 8:00AM to 6:00PM PST

D-Link Technical Support over the Internet: http://support.dlink.com email:[email protected]

Tech Support for customers within Canada:

D-Link Technical Support over the Telephone:

(800) 361-5265

Monday to Friday 7:30am to 12:00am EST

D-Link Technical Support over the Internet:

217

Technical Support

You can find software updates and user documentation on the D-Link websites.

D-Link provides free technical support for customers within Canada, the United Kingdom, and Ireland.

Customers can contact D-Link technical support through our websites, or by phone.

For Customers within

The United Kingdom & Ireland:

D-Link UK & Ireland Technical Support over the Telephone:

08456 12 0003 (United Kingdom)

+44 8456 12 0003 (Ireland)

Lines Open

8.00am-10.00pm Mon-Fri

10.00am-7.00pm Sat & Sun

D-Link UK & Ireland Technical Support over the Internet: http://www.dlink.co.uk ftp://ftp.dlink.co.uk

For Customers within Canada:

D-Link Canada Technical Support over the Telephone:

1-800-361-5265 (Canada)

Monday to Friday 7:30 am to 3:00 am ET

Saturday and Sunday 9:00am to 12:00am ET

D-Link Canada Technical Support over the Internet:

218

Technische Unterstützung

Aktualisierte Versionen von Software und Benutzerhandbuch finden Sie auf der Website von D-Link.

D-Link bietet kostenfreie technische Unterstützung für Kunden innerhalb

Deutschlands, Österreichs, der Schweiz und Osteuropas.

Unsere Kunden können technische Unterstützung über unsere Website, per E-Mail oder telefonisch anfordern.

Web: http://www.dlink.de

E-Mail: [email protected]

Telefon: +49 (1805)2787

0,12€/Min aus dem Festnetz der Deutschen Telekom.

Telefonische technische Unterstützung erhalten Sie Montags bis Freitags von 09.00 bis 17.30 Uhr.

Unterstützung erhalten Sie auch bei der Premiumhotline für D-Link

Produkte unter der Rufnummer 09001-475767

Montag bis Freitag von 6-22 Uhr und am Wochenende von 11-18 Uhr.

1,75€/Min aus dem Festnetz der Deutschen Telekom.

219

Assistance technique

Vous trouverez la documentation et les logiciels les plus récents sur le site web D-Link.

Ceux-ci peuvent contacter le service technique de

D-Link par notre site internet ou par téléphone.

Support technique destiné aux clients établis en France:

Assistance technique D-Link par téléphone :

0 820 0803 03

Assistance technique D-Link sur internet : http://www.dlink.fr e-mail : [email protected]

Support technique destiné aux clients établis au

Canada :

Assistance technique D-Link par téléphone :

(800) 361-5265

Lun.-Ven. 7h30 à 21h00 HNE.

Assistance technique D-Link sur internet : http ://support.dlink.ca e-mail : [email protected]

220

Asistencia Técnica

Puede encontrar el software más reciente y documentación para el usuario en el sitio web de

D-Link . D-Link ofrece asistencia técnica gratuita para clientes dentro de España durante el periodo de garantía del producto. Los clientes españoles pueden ponerse en contacto con la asistencia técnica de D-Link a través de nuestro sitio web o por teléfono.

Asistencia Técnica de D-Link por teléfono:

902 304545 de lunes a viernes desde las 9:00 hasta las14:00 y de las

15:00 hasta las 18:00

Asistencia Técnica de D-Link a través de Internet:

http://www.dlink.es email: [email protected]

221

Supporto tecnico

Gli ultimi aggiornamenti e la documentazione sono disponibili sul sito D-Link.

Supporto tecnico per i clienti residenti in Italia

D-Link Mediterraneo S.r.L.

Via N. Bonnet 6/B 20154 Milano

Supporto Tecnico dal lunedì al venerdì dalle ore

9.00 alle ore 19.00 con orario continuato

Telefono: 02-39607160

URL : http://www.dlink.it/supporto.html

Email: [email protected]

222

Technical Support

You can find software updates and user documentation on the D-Link website.

D-Link provides free technical support for customers within Benelux for the duration of the warranty period on this product.

Benelux customers can contact D-Link technical support through our website, or by phone.

Tech Support for customers within the Netherlands:

D-Link Technical Support over the Telephone:

0900 501 2007

Monday to Friday 8:00 am to 10:00 pm

D-Link Technical Support over the Internet: www.dlink.nl

Tech Support for customers within Belgium:

D-Link Technical Support over the Telephone:

+32(0)2 717 3248

Monday to Friday 8:00 am to 10:00 pm

D-Link Technical Support over the Internet: www.dlink.be

Tech Support for customers within

Luxemburg:

D-Link Technical Support over the Telephone:

+352 342 080 82 13

Monday to Friday 8:00 am to 10:00 pm

D-Link Technical Support over the Internet: www.dlink.be

223

Pomoc techniczna

Najnowsze wersje oprogramowania i dokumentacji użytkownika można znaleźć w serwisie internetowym firmy D-Link.

D-Link zapewnia bezpłatną pomoc techniczną klientom w Polsce w okresie gwarancyjnym produktu.

Klienci z Polski mogą się kontaktować z działem pomocy technicznej firmy D-Link za pośrednictwem Internetu lub telefonicznie.

Telefoniczna pomoc techniczna firmy D-Link:

(+48 12) 2-999-333

Pomoc techniczna firmy D-Link świadczona przez

Internet:

URL: http://www.dlink.pl e-mail: [email protected]

224

Technická podpora

Aktualizované verze software a uživatelských příruček najdete na webové stránce firmy D-Link.

D-Link poskytuje svým zákazníkům bezplatnou technickou podporu

Zákazníci mohou kontaktovat oddělení technické podpory přes webové stránky, mailem nebo telefonicky

Web: http://www.dlink.cz/suppport/

E-mail: [email protected]

Telefon: 0224247500

Telefonická podpora je v provozu:

225

Technikai Támogatás

Meghajtó programokat és frissítéseket a D-Link

Magyarország weblapjáról tölthet le.

Telefonon technikai segítséget munkanapokon hétfőtőlcsütörtökig 9.00 – 16.00 óráig és pénteken 9.00 – 14.00

óráig kérhet a (1) 461-3001 telefonszámon vagy a [email protected] emailcímen.

Magyarországi technikai támogatás :

D-Link Magyarország

1074 Budapest, Alsóerdősor u. 6. – R70 Irodaház 1 em.

Tel. : 06 1 461-3001

Fax : 06 1 461-3004 email : [email protected]

URL : http://www.dlink.hu

226

Teknisk Support

Du kan finne programvare oppdateringer og bruker dokumentasjon på D-Links web sider.

D-Link tilbyr sine kunder gratis teknisk support under produktets garantitid.

Kunder kan kontakte D-Links teknisk support via våre hjemmesider, eller på tlf.

Teknisk Support:

D-Link Teknisk telefon Support:

800 10 610

(Hverdager 08:00-20:00)

D-Link Teknisk Support over Internett:

http://www.dlink.no

227

Teknisk Support

Du finder software opdateringer og bruger- dokumentation på D-Link’s hjemmeside.

D-Link tilbyder gratis teknisk support til kunder i Danmark i hele produktets garantiperiode.

Danske kunder kan kontakte D-Link’s tekniske support via vores hjemmeside eller telefonisk.

D-Link teknisk support over telefonen:

Tlf. 7026 9040

Åbningstider: kl. 08:00 – 20:00

D-Link teknisk support på Internettet:

http://www.dlink.dk

228

Teknisk Support

På vår hemsida kan du hitta mer information om mjukvaru uppdateringar och annan användarinformation.

D-Link tillhandahåller teknisk support till kunder i Sverige under hela garantitiden för denna produkt.

Teknisk Support för kunder i Sverige:

D-Link Teknisk Support via telefon:

0770-33 00 35

Vardagar 08.00-20.00

D-Link Teknisk Support via Internet:

http://www.dlink.se email:[email protected]

229

Teknistä tukea asiakkaille

Suomessa:

D-Link tarjoaa teknistä tukea asiakkailleen.

Tuotteen takuun voimassaoloajan.

Tekninen tuki palvelee seuraavasti:

Arkisin klo. 9 - 21

numerosta

0800-114 677

Internetin kautta

Ajurit ja lisätietoja tuotteista. http://www.dlink.fi

Sähköpostin kautta voit myös tehdä kyselyitä.

230

Teknisk Support

På vår hemsida kan du hitta mer information om mjukvaru uppdateringar och annan användarinformation.

D-Link tillhandahåller teknisk support till kunder i Sverige under hela garantitiden för denna produkt.

Teknisk Support för kunder i Sverige:

D-Link Teknisk Support via telefon:

0770-33 00 35

Vardagar 08.00-20.00

D-Link Teknisk Support via Internet:

http://www.dlink.se

231

Ver 1.00

232

Intenational Offices

U.S.A

17595 Mt. Herrmann Street

Fountain Valley, CA. 92708

TEL: 714-885-6000

Fax 866-743-4905

URL: www.dlink.com

Canada

2180 Winston Park Drive

Oakville, Ontario, L6H 5W1

Canada

TEL: 1-905-8295033

FAX: 1-905-8295223

URL: www.dlink.ca

Europe (U. K.)

4th Floor, Merit House

Edgware Road, Colindale

London NW9 5AB

U.K.

TEL: 44-20-8731-5555

FAX: 44-20-8731-5511

URL: www.dlink.co.uk

Germany

Schwalbacher Strasse 74

D-65760 Eschborn

Germany

TEL: 49-6196-77990

FAX: 49-6196-7799300

URL: www.dlink.de

France

Le Florilege #.2, Allee de la Fresnerie

78330 Fontenay le Fleury

France

TEL: 33-1-30238688

FAX: 33-1-30238689

URL: www.dlink-france.fr

Netherlands

Weena 290

3012 NJ Rotterdam

Netherlands

Tel: +31-10-282-1445

Fax: +31-10-282-1331

URL: www.dlink-benelux.com

Belgium

Rue des Colonies 11

B-1000 Brussels

Belgium

Tel: +32(0)2 517 7111

Fax: +32(0)2 517 6500

URL: www.dlink-benelux.com

Italy

Via Nino Bonnet n. 6/b

20154 – Milano,

Italy

TEL: 39-02-2900-0676

FAX: 39-02-2900-1723

URL: www.dlink.it

Sweden

P.O. Box 15036, S-167 15 Bromma

Sweden

TEL: 46-(0)8564-61900

FAX: 46-(0)8564-61901

URL: www.dlink.se

Denmark

Naverland 2, DK-2600

Glostrup, Copenhagen,

TEL: 45-43-969040

FAX: 45-43-424347

URL:www.dlink.dk

Norway

Karihaugveien 89

1086 Oslo

Norway

TEL: 47-23-897189

FAX: 47-22-309085

URL: www.dlink.no

Iberia

C/Sabino De Arana,

56 Bajos

08028 Barcelona

TEL: 34 93 4090770

FAX: 34 93 4910795

URL: www.dlinkiberia.es

Singapore

1 International Business Park

#03-12 The Synergy

Singapore 609917

TEL: 65-6774-6233

FAX: 65-6774-6322

URL: www.dlink-intl.com

Australia

1 Giffnock Avenue,

North Ryde, NSW 2113

Australia

TEL: 61-2-8899-1800

FAX: 61-2-8899-1868

URL: www.dlink.com.au

India

D-Link House, Kurla Bandra Complex Road,

Off CST Road, Santacruz (East), Mumbai - 400098.

India

TEL: 91-022-26526696/56902210

FAX: 91-022-26528914

URL: www.dlink.co.in

Middle East (Dubai)

P.O.Box: 500376

Office No.:103, Building:3

Dubai Internet City

Dubai, United Arab Emirates

Tel:+971-4-3916480

Fax:+971-4-3908881

URL: www.dlink-me.com

Turkey

Maslak Ayazaga Yolu

No: 2 Kat :5

Ayazaga-Istanbul

TURKEY

TEL: 0090 212 289 56 59

FAX: 0090 212 289 76 06

URL: www.dlink.com.tr

Egypt

19 El-Shahed Helmy, El Masri

Al-Maza, Heliopolis

Cairo,Egypt.

TEL:+202 414 4295

FAX:+202 415 6704

URL: www.dlink-me.com

Israel

11 Hamanofim Street

Ackerstein Towers, Regus Business Center

P.O.B 2148, Hertzelia-Pituach 46120.

Israel

TEL: +972-9-9715700

FAX: +972-9-9715601

URL: www.dlink.co.il

Latin America

Isidora Goyeechea 2934 of 702,

Las Condes

Santiago – Chile S.A.

TEL: 56-2-232-3185

FAX: 56-2-232-0923

URL: www.dlink.cl

Brasil

Av das Nacoes Unidas,

11857 - 14 - andar - cj 141/142

Brooklin Novo

Sao Paulo - SP - Brazil

CEP 04578-000

TEL: +55 11 55039320

FAX: +55 11 55039322

URL: www.dlinkbrasil.com.br

South Africa

Einstein Park II

Block B

102-106 Witch-Hazel Avenue

Highveld Technopark

Centurion

Gauteng

Republic of South Africa

TEL: 27-12-665-2165

FAX: 27-12-665-2186

URL: www..d-link.co.za

Russia

Grafsky per., 14, floor 6

Moscow

129626 Russia

TEL: 7-095-744-0099

FAX: 7-095-744-0099 #350

URL: www.dlink.ru

China

No.202,C1 Building, Huitong Office Park,

No.71, Jianguo Road, Chaoyang District, Beijing,

100025, China.

TEL +86-10-58635800

FAX: +86-10-58635799

URL: www.dlink.com.cn

Taiwan

2F, No. 119, Pao-Chung Rd.

Hsin-Tien, Taipei

Taiwan

TEL: 886-2-2910-2626

FAX: 886-2-2910-1515

URL: www.dlinktw.com.tw

Headquarters

2F, No. 233-2, Pao-Chiao Rd.

Hsin-Tien, Taipei

Taiwan

TEL: 886-2-2916-1600

FAX: 886-2-2914-6299

URL:www.dlink.com

Registration Card

(All Countries and Regions excluding USA)

Print, type or use block letters.

Your name: Mr./Ms _____________________________________________________________________________

Organization: ________________________________________________ Dept. ____________________________

Your title at organization: ________________________________________________________________________

Telephone: _______________________________________ Fax:________________________________________

Organization's full address: ______________________________________________________________________

____________________________________________________________________________________________

Country: _____________________________________________________________________________________

Date of purchase (Month/Day/Year): _______________________________________________________________

Product Model Product Serial

No.

* Product installed in type of computer (e.g., Compaq 486)

* Product installed in computer serial No.

(* Applies to adapters only)

Product was purchased from:

Reseller's name: ______________________________________________________________________________

Telephone: _______________________________________ Fax:________________________________________

Reseller's full address: _________________________________________________________________________

_________________________________________________________________________

_________________________________________________________________________

Answers to the following questions help us to support your product:

1. Where and how will the product primarily be used?

† Home †Office †Travel †Company Business †Home Business †Personal Use

2. How many employees work at installation site?

† 1 employee †2-9 †10-49 †50-99 †100-499 †500-999 †1000 or more

3. What network protocol(s) does your organization use ?

† XNS/IPX †TCP/IP †DECnet †Others_____________________________

4. What network operating system(s) does your organization use ?

† D-Link LANsmart †Novell NetWare †NetWare Lite †SCO Unix/Xenix †PC NFS †3Com 3+Open

† Banyan Vines †Windows NT †Windows ME †Windows 2000 †Windows XP

† Others__________________________________________

5. What network management program does your organization use ?

† D-View †HP OpenView/Windows †HP OpenView/Unix †SunNet Manager †Novell NMS

† NetView 6000 †Others________________________________________

6. What network medium/media does your organization use ?

† Fiber-optics †Thick coax Ethernet †Thin coax Ethernet †10BASE-T UTP/STP

† 100BASE-TX †100BASE-T4 †100VGAnyLAN †Others_________________

7. What applications are used on your network?

† Desktop publishing †Spreadsheet †Word processing †CAD/CAM

† Database management †Accounting †Others_____________________

8. What category best describes your company?

† Aerospace †Engineering †Education †Finance †Hospital †Legal †Insurance/Real Estate †Manufacturing

† Retail/Chainstore/Wholesale †Government †Transportation/Utilities/Communication †VAR

† System house/company †Other________________________________

9. Would you recommend your D-Link product to a friend?

† Yes †No †Don't know yet

10.Your comments on this product?

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Key Features

  • Managed Web-based management
  • Quality of Service (QoS) support
  • Basic switching RJ-45 Ethernet ports quantity: 24
  • Stackable

Related manuals