Unitech MS120 Manual
Add to my manuals35 Pages
Unitech MS120 is a versatile data collection tool designed to optimize your business operations. With its user-friendly interface and advanced capabilities, the MS120 empowers you to capture and transmit data accurately and efficiently. Whether you're in retail, healthcare, logistics, or any other industry, the MS120 offers a range of features to meet your specific needs. From 1D and 2D barcode scanning to data storage and transfer, the MS120 streamlines your workflow and improves productivity.
advertisement
Contents
Setup Procedures …………… 2
Batch Setup …………… 3
Bar Code Setup Menu …………… 4
1 Device Selection and Default
…………… 4
2 Beep and Delay …………… 6
3 Keyboard Wedge …………… 8
4 RS232 Serial Setting …. 10
5 Scanner ………….. 12
6 Data Format ………..… 14
7 Symbologies(I): Code 39/I2 of 5/
S2 of 5/Delta Distance
Code/Code 32 ..………… 16
1
8 Symbologies(II): Code 128 /
MSI / Code 93 / Codabar /Label
Code ………….. 18
9 Symbologies(III): UPC/EAN
………….. 20
Function Code for PC .… 22
Function Code for MAC …. 24
Function Code for IBM Terminal
………..… 26
Full ASCII Table ………….. 28
Test Chart …………………... 34
Setup Procedures
1) Locate a group that contains the parameters to be changed.
2) Scan the “Enter Group” label. The
Reader will sound 3 beeps to indicate that setup is in progress.
3) Scan the label representing the parameter to be changed.
4) Scan the labels representing the parameter values.
2
5) Repeat the above two steps, if necessary, to change the parameters in the same group.
6) Scan the “Exit” label to end the group currently selected. The Reader will sound 2 beeps.
7) Repeat the procedure for other groups, if needed, which include the parameters to be changed.
Batch Setup
Having configured a scanner, you may duplicate the settings of the scanner
(master) to the others. You can do this by producing a set of custom setup labels derived from the master scanner and scanning these labels by other scanners.
The following label is called “dump settings” label. Scan that label, the settings of a scanner will dump to the screen as one or several ASCII string(s). Printing the string(s) into bar code labels in Code 39, you get the batch setup labels to duplicate other scanner.
Dump Settings
3
Bar Code Setup Menu
1 Device Selection and Default
Enter Group 1
Group Default
0 1
2 3
4 5
6
8
Factory Default
Exit
4
7
9
Device
ID
Keyboard Wedge Reader
Device Type
00 IBM PC/XT
01 IBM PC/AT, PS/2 mod 40, 60,
80 etc.
02 IBM PS/2 MOD 25, 56, 70, 90
19 IBM 5550-5P
20 IBM 5550-6P
08 IBM 3196/3197 122 Keys
10 IBM 3476/3477 122 Keys
09 IBM 3179/3471/3472
11 IBM 3486/3487
06 Keyboardless Wedge
03 Macintosh ADB bus
Device
ID
RS-232 Reader
Device Type
04 RS232 Serial Decoder
Device
ID
Wand Emulation Reader
Device Type
05 Wand Emulation (Native Mode)
07 Wand Emulation (Code 39 Mode)
5
2 Beep and Delay
Enter Group 2
Group Default
0 1
2 3
4 5
6 7
8 9
F5 (%VE)
Exit
6
Beep Tone
(On Decoding):
0 None
1 Low
2 Medium
Beep Tone
(On ACK):
0 None
1 Low
2 Medium
A1
3 High
4 Low to High
5 High to Low
A2
3 High
4 Low to High
5 High to Low
Inter-Character
Delay:
0 1 ms
1 5 ms
2 10 ms
A3
3 20 ms
4 50 ms
5 100 ms
Inter-Block Delay:
0 10 ms
1 50 ms
2 100 ms
A4
3 500 ms
4 1 second
5 5 seconds
7
3 Keyboard Wedge
Enter Group 3
Group Default
0 1
2 3
4 5
6 7
8 9
Review
Exit
8
Function Code:
B1
0 Off 1 On
Upper/Lower
Case:
B2
0 Lower Case 1 Upper Case
Function Code:
B3
0 US
1 UK
2 Swiss
3 Swedish
4 Spanish
5 Norwegian
6 Italian
7 German
8 French
9 Alt Key Mode
9
4 RS232 Serial Setting
Enter Group 4
Group Default
0 1
2 3
4 5
6 7
8 9
Review
Exit
10
Baud Rate:
0 300
1 600
2 1200
3 2400
Parity:
C1
4 4800
5 9600
6 19200
0 Even
1 Odd
2 Mark
Data Bit:
C2
3 Space
4 None
C3
0 7
BCC character:
1 8
1 On
C4
0 Off
Time Out:
0 1 second
1 3 seconds
C5
2 10 seconds
3 No limit
11
5 Scanner
0
2
4
6
8
Enter Group 5
Group Default
1
3
5
7
9
Review
Exit
12
Double
verification:
0 Off 1 On
D1
Label Type:
D4
0 Positive 1 Positive and Negative
Output of Wand:
D5
0 Bar High / Space Low
1 Bar Low / Space High
Level Duration:
0 200 us
D6
1 600 us
13
6 Data Format
Enter Group 6
Group Default
0
2
1
Review
Exit
Default Code ID Table
Sym- bology
UPC-A
UPC-E
EAN-13
EAN-8
I 2 OF 5
S 2 OF 5
Code 39
Codabar
Code93
Code 128
MSI
Code 11
Set1 Set2
A A
E C
F A
FF B
I I
H H
M Y
N N
L L
K K
O M
J J
If the “User Defined” option is selected, the default ID is Set1.
Data Format:
4
5
6
7
8
9
3
Preamble Code ID Length Data
Terminator Postamble BCC
14
Terminator:
E1
0 Enter (CR/LF) 2 Return(LF)
1 Field Exit(CR) 3 None
Code ID:
E2
0 None 2 Default Set I
1 User Defined 3 Default Set II
Define Code ID:
E3
00 Code 39 Full ASCII 07 Codabar
01 Code 39 Standard 08 Code128
02 EAN-13 09 Code 93
03 UPC-A
04 EAN-8
05 UPC-E
06 I 2 of 5
10 S 2 of 5
11 MSI
12 Code 11
13
Data Length:
0 Exclude
E4
1 Include
PP
Preamble:
Scan “PP” to program preamble. Scan characters from Full ASCII table to define preamble.
Maximum 16 characters.
Scan “PP” to end.
OO
Postamble:
Scan “OO” to program preamble. Scan characters from Full ASCII table to define preamble.
Maximum 16 characters.
Scan “OO” to end.
15
7 Symbologies(I): Code 39/I2 of 5/
S2 of 5/Delta Distance Code/Code 32
0
Enter Group 7
Group Default
1
2 3
4 5
6 7
8 9
MM Minimum Length NN Maximum Length
Review
Code 32:
Exit
F5
0/1 Disable/Enable
2/3 Leading Character Send / No Send
4/5 Trailing Character Send /No Send
16
Code 39:
0/1 Disable/Enable
4 Check Digit Calculate and Send
F1
2/3 Full ASCII/Standard
5 Check Digit Calculate but Not Send
6 Check Digit Not Calculate
7/8 Send/Not Send Start & Stop
0~48 Min 0 / Max 48
Interleaved
2 of 5:
F2
0/1 Disable/Enable
2/3 Fix Length On/Off (by first three reads)
4 Check Digit Calculate and Send
5 Check Digit Calculate but Not Send
6 Check Digit Not Calculate
7 First Digit Suppressed.
8 Last Digit Not Suppressed.
9 Not Suppressed.
4~64 Min 10 / Max 64
Standard 2 of 5 /
Toshiba:
F3
0/1 Disable/Enable
2/3 Fix Length On/Off
4 Check Digit Calculate and Send
5 Check Digit Calculate but Not Send
6 Check Digit Not Calculate
4~48 Min 8 / Max 48
Delta Distance
Code:
F4
0/1 Disable/Enable
2/3 Check Digit Not Send / Send
4/5 Check Digit Calculate/Not Calculate
17
8 Symbologies(II): Code 128 / MSI /
Code 93 / Codabar /Label Code
0
Enter Group 8
Group Default
1
2 3
4 5
6 7
8 9
MM Minimum Length NN Maximum Length
Review Exit
18
Code 128 / Label
Code:
G1
0/1 Disable/Enable 1~64 Min 1 / Max 64
MSI / Plessey
Code:
G2
0/1 Disable/Enable 2/3 CD Send / No Send
4 CD Double Module 10
5 CD Double Module 11 Plus 10
6 CD Module 10 or 11
1-16 Min 1 / Max 16
Code 93:
G3
0/1 Disable/Enable 1~48 Min 1 / Max 48
Code 11:
G4
0/1 Disable/Enable 2/3 One/Two CD
4/5 CD Send / No Send
1-48 Min 1 / Max 48
Codabar:
G5
0/1 Disable/Enable 2/3 S & S Send / No Send
4 CD Check & Send
5 CD Check but not Send
6 CD not Check
7/8 CLSI Format On / Off
3-48 Min 3 / Max 48
19
9 Symbologies(III): UPC/EAN
0
Enter Group 9
Group Default
1
2 3
4 5
6 7
8 9
Review
Exit
20
UPC-A:
0/1 Disable/Enable
2/3 First Digit Send / No Send
4/5 CD Send / No Send
UPC-E:
0/1 Disable/Enable
2/3 First Digit Send / No Send
4/5 CD Send / No Send
6/7 Zero Expansion On / Off
EAN-13:
0/1 Disable/Enable
2/3 First Digit Send / No Send
4/5 CD Send / No Send
6/7 ISBN Enable / Disable
EAN-8:
0/1 Disable/Enable
2/3 First Digit Send / No Send
4/5 CD Send / No Send
Supplement Code:
0/1 2 Add-on Code Off / On
2/3 5 Add-on Code Off / On
4 Transmitted if Present
5 Must Present.
6/7 Space Added / Not Added
H1
H2
H3
H4
H5
21
Function Code for PC
F1 (%VA) F2 (%VB)
F3 (%VC) F4 (%VD)
F5 (%VE) F6 (%VF)
F7 (%VG) F8 (%VH)
F9 (%VI) F10 (%VJ)
F11 (%VK) F12 (%VL)
Cursor Right (/FC) Cursor Left (/FD)
Cursor Up (/FE) Cursor Down (/FF)
PgUp (/FG)
TAB (/FI)
ESC (/FK)
Back Tab (/FJ)
PgDn (/FH)
Enter (/FL)
Right Ctrl (/FO) Right Enter(/FM)
22
Del (/FX) Ins (/FW)
23
Function Code for MAC
F1 (%VA)
F3 (%VC)
F5 (%VE)
F7 (%VG)
F9 (%VI)
F11 (%VK)
F13 (%VM)
F15 (%VO)
F2 (%VB)
F4 (%VD)
F6 (%VF)
F8 (%VH)
F10 (%VJ)
F12 (%VL)
F14 (%VN)
Cursor Left (/FD)
Cursor Right (/FC) Cursor Down (/FF)
Cursor Up (/FE) Page down (/FH) page up (/FG) ins (/FJ)
Ttab (/FI) Enter (/FL)
24
Esc (/FK) return (/FM)
Option Make (%VP) Option Break (%VQ)
Control Make (%VR) Control Break (%VS)
Shift Make (%VT) Shift Break (%VU)
Apple Make (%VV) Apple Break (%VW)
25
Function Code for IBM Terminal
F1 (%VA)
F3 (%VC)
F5 (%VE)
F7 (%VG)
F9 (%VI)
F11 (%VK)
F13 (%VM)
F15 (%VO)
F17 (%VQ)
F19 (%VS)
F21 (%VU)
F23 (%VW)
F2 (%VB)
F4 (%VD)
F6 (%VF)
F8 (%VH)
F10 (%VJ)
F12 (%VL)
F14 (%VN)
F16 (%VP)
F18 (%VR)
F20 (%VT)
F22 (%VV)
F24 (%VX)
26
Home (/FA)
TAB (/FI)
Return (/FM)
Field + (/FP)
End (/FB)
Enter (/FL)
Field Exit (/FO)
Field - (/FQ)
RESET (/FV)
27
Full ASCII Table
NUL (%U)
STX ($B)
EOT ($D)
ACK ($F)
BS ($H)
LF ($J)
FF ($L)
SO ($N)
DLE ($P)
DC2 ($R)
DC4 ($T)
SYN ($V)
28
SOH ($A)
ETX ($C)
ENQ ($E)
BEL ($G)
HT ($I)
VT ($K)
CR ($M)
SI ($O)
DC1 ($Q)
DC3 ($S)
NAK ($U)
ETB ($W)
CAN ($X)
SUB ($Z)
FS (%B)
RS (%D)
SP
” (/B)
$
& (/F)
( (/H)
* (/J)
, (/L)
.
29
EM ($Y)
ESC (%A)
GS (%C)
US (%E)
! (/A)
# (/C)
%
’ (/G)
) (/I)
+
-
/
0
2
4
6
8
: (/Z)
< (%G)
> (%I)
@ (%V)
B
D
F
30
1
3
5
7
9
; (%F)
= (%H)
? (%J)
A
C
E
G
H
J
L
N
P
R
T
V
X
Z
\ (%L)
^ (%N)
31
I
K
M
O
Q
S
U
W
Y
[ (%K)
] (%M)
_ (%O)
` (%W) b (+B) d (+D) f (+F) h (+H) j (+J) l (+L) n (+N) p (+P) r (+R) t (+T) v (+V)
32 a (+A) c (+C) e (+E) g (+G) i (+I) k (+K) m (+M) o (+O) q (+Q) s (+S) u (+U) w (+W)
x (+X) z (+Z)
| (%Q)
~ (%S) y (+Y)
{(%P)
} (%R)
DEL (%T)
33
Test Chart
EAN-13
3 0 4 5 2 1 4 8 3 4 1 2 3
EAN-8
8 0 1 2 3 4 5 3
UPC-A
0 4 7 6 6 9 1 3 7 1 6
UPC-E
9 9
6
0 1 2 3 4 5 7 2
ISBN 957-630-239-0
0 0 2 7 0
9 7 8 9 5 7 6 3 0 2 3 9 8
34
W+ E + D + G + E
Code 39 with C/D
UNI T E C H- E
Interleaved 2 of 5
0987654321
Codabar
A2 2 3 5 7 0 0 0 5 9 9 8 7 6 B
MSI
12345- 5
35
advertisement