N ET K EY
NETWORK COMPONENTS
CONTRACTOR GRADE
© Panduit Corp. 2008
N ET K EY
Category 5e & 6 Jack Modules
Part Number: NKP5E88M**, NK688M**
INSTALLATION INSTRUCTIONS NK406A
Retention
Cap
1
Orient jack as shown
Label
Notch
Puck
(NKSPB)
2
CWST
3
P4
T568B
P3 P4
T568A
P2
4
Trim pair separator and/or filler if present.
Option 1 Option 2 5
P1 P2
(T568B shown)
P1 P3
(T568B shown)
** Denotes color.
T568 BA BA
Do not untwist more then 1/8" from the IDC tower
T568 BA BA
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 1 of 2
PDT110
Tool
7
8
10
INSTALLATION INSTRUCTIONS NK406A
9
11
T568 BA BA
Notes:
1. For specified performance, follow TIA/EIA 568-B installation guidelines.
2. Jack Modules can terminate PVC or Plenum rated 22-26 AWG solid or stranded IWC cable with 0.048 inch (1.2 mm) maximum insulated conductor outside diameter.
3. Jack Modules may be re-terminated a minimum of 20 times.
4. For technical and performance information, consult PANDUIT Technical Support.
As with all Communication Components, the following statements apply:
1. Never install communications wiring during a lightning storm.
2. Never install communications wiring in wet locations unless the jack is specifically designed for use in wet locations.
3. Never touch uninsulated communications wiring or terminals unless the communication line has been disconnected at the network interface.
4. Use caution when installing or modifying communication wiring.
For Instructions in Local Languages and Technical Support: www.panduit.com/resources/install_maintain.asp