Digitus DN-15023 User manual


Add to my manuals
23 Pages

advertisement

Digitus DN-15023 User manual | Manualzz

POWERLINE HIGH SPEED

NETWORK BRIDGE

User Manual

Contents

1 Introduction ........................................................................................................ 1

1.1

System Requirements ........................................................................... 1

1.2

Packing List ........................................................................................... 1

2 Safety Precautions ............................................................................................. 2

3 Adapter ............................................................................................................... 3

3.1

Ethernet Interface .................................................................................. 3

3.2

Buttons .................................................................................................. 3

3.3

LEDs ...................................................................................................... 4

4 Utility Installation ................................................................................................ 6

5 How to Use the Utility ......................................................................................... 9

5.1

Main Tab ................................................................................................ 9

5.2

Privacy Tab .......................................................................................... 12

5.3

Diagnostics Tab ................................................................................... 13

5.4

About Tab ............................................................................................ 15

6 How to Use the NMK Pushbutton .................................................................... 16

6.1

Forming a HomePlug AV Logical Network ........................................... 16

6.2

Joining a Network ................................................................................ 17

6.3

Leaving a Network ............................................................................... 18

Appendix A Specifications ................................................................................. 19

Appendix B Acronyms and Abbreviations ......................................................... 20

Appendix C About QoS ...................................................................................... 21 i

1 Introduction

The Powerline Adapter (also called “the device” hereinafter) is a low power consumption PLC device developed based on the master chip of INT6400. It can transmit the network data in the power line. The device is compatible with the latest requirements of the EUP Directive. When the device enters the lower power consumption mode, the consumption is less than 1W.

The device can detect 200 Mbps PLC-Ethernet bridge devices in the power line network, measure data rate performance, ensure the security of the powering network, and perform system diagnosis.

1.1 System Requirements

Operating System

CPU

RAM

Screen Resolution

Free Disk Space

Network Interface

Windows 7, Vista, XP

Intel Pentium III or higher and clock rate faster than 2.0 GHz are recommended.

At least 128 MB

Any resolution

At least 20 MB

At least one fast Ethernet (100 Mbps) network interface card (NIC) and one

Ethernet cord

1.2 Packing List

 200 Mbps Powerline Adapter(s)

 CD-ROM

 Quick Installation Guide

 RJ45 Ethernet cable(s)

1

2 Safety Precautions

This device is used for to connect to the AC power line. Before using the device, read the instructions carefully, in order to use the device correctly and safely. For the installation instructions, refer to the installation section of this guide.

 Follow all the warnings and instructions marked on the product.

 Before cleaning the device, unplug it from the wall outlet. Use a dry cloth for cleaning. Do not use liquid cleaners or aerosol cleaners.

 Do not place the device near water.

 Do not place the device near or over a radiator or heat register.

 Do not use an extension cord between the device and the AC power source.

 Only professional technicians should service the device. Opening or removing covers may result in exposure to dangerous voltage points or other risks.

 Unplug the device from the wall outlet and refer to professional service personnel for the following conditions:

– If liquid has been spilled into the product

– If the device has been exposed to rain or water

– If the device does not operate normally when following the operation instructions

– If the device exhibits a distinct change in performance

2

3 Adapter

3.1 Ethernet Interface

Use one end of a network cable to connect the Ethernet interface. Use the other end of the cable to connect the Ethernet interface of the computer or another

Ethernet-enabled network device.

3.2 Buttons

Figure 1 Side panel of the device

Reset: Restore the factory defaults.

Security: Join a secured network.

 Pressing and holding the button for more than 10 seconds randomizes the security.

 Pressing and holding the button for more than 3 seconds makes the adapter a member of the existing security (the button of the other device must be pushed as well).

3

3.3 LEDs

There are 3 LEDs on the front panel to indicate the status of the adapter.

Figure 2 Top view

The following table describes the LEDs on the device.

LED Color

Green

Behavior

On

Description

Power is on

 System enters the power save mode.

Power Green Blink

- Off

Ethernet Green On

 System is resetting.

 System is in the process of security setup.

Power is off.

The device is connecting to other devices via the Ethernet interface

4

LED

Data

Behavior Color

Green Blink

Description but not communicating with them.

The device is receiving or transmitting data via the Ethernet interface.

The device is not connecting to

Green/Red On interface.

The device has connected to the power line network. The Data LED color will vary according to the physical rate.

 Green: Link Rate > 40 Mbps

 Orange: 20 Mbps< Link Rate

<40 Mbps

 Red: Link Rate< 20 Mbps

When the device is scanning other blink quickly.

The adapter has not found any encryption key.

Note:

The Power, Ethernet and Data indicators blink quickly when the device is powered on.

At that moment, the Power and Ethernet indicators are green, and the Data indicator is orange.

5

4 Utility Installation

Note:

Before installing the PLC utility software, make sure that there is no any other power line utility installed on your computer. If there is another utility installed, please uninstall it and restart your computer.

Follow the steps below to install the utility. No password or CD-Key is needed.

Step1 Please insert the utility CD into the computer’s CD-ROM drive. Select the

PLC 200AV Utility Installation folder and then double-click the setup.exe.

A page for installing the utility appears.

Figure 3 Opening the setup wizard

Step2 Click Next > to display the following page.

6

Figure 4 Selecting the installation folder

Step3 Click Browse… to select the installation folder, and then click Next > to continue.

7

Figure 5 Completing the installation

Step4 Click Close to complete the installation.

8

5 How to Use the Utility

5.1 Main Tab

The Main screen provides a list of all power line devices logically connected to the computer when the utility is running.

The top panel shows local HomePlug devices connected to the network interface card (NIC) of the computer. Click Connect. The utility automatically scans the power line periodically for other HomePlug devices when it is connected to the local device.

If no local HomePlug device is discovered, the status bar displays NO HOMEPLUG

ADAPTERS DETECTED.

Figure 6 Main tab

The lower panel displays all the HomePlug remote devices, which are discovered in the current logical network. The total number of remote devices connected in the same network is displayed above the remote device panel. Network type (Public or

Private) depends on the network status of the local device. Autoscan shows whether the autoscan function is on. The following information is displayed for all devices that appear in the lower panel.

9

Device Name

This column shows the default device name, which may be modified. To change the name, click Rename or click the name and edit it in the list.

MAC Address

This column shows the MAC addresses of the remote devices.

Password

By default, this column is blank. You can click Enter Password to change it. The procedure for setting the password of the device (required when creating a private network) is as follows:

Step1 Click the device name to select the device in the lower panel.

Step2 Click Enter Password. A dialog box appears, showing the device name and password. See Figure 7.

Figure 7 Setting a device password

10

Step3 Click OK to verify the password. The password field accepts the device password in any case formats, with or without dash.

A confirmation box appears if the password is entered correctly. If a device is not found, a message appears, providing suggestions to solve the common problems.

This process takes a few seconds.

Add

This button is used to add a remote device to the existing network by entering the device password of the device. A dialog box appears. See Figure 8. You can enter a device name and the password.

If the device is found and the password is entered correctly, a confirmation box appears. If a device is not found, a message appears, providing suggestions to solve the common problems.

Figure 8 Adding a remote device

Note:

The device must be in the power line (plugged in), so that you can confirm the password and add the device to the network. If the device is not located, a warning message appears.

11

Scan

This button is used to perform an immediate search for HomePlug devices connected to the Power line network. By default, the utility automatically scans every a few seconds and updates the displayed information.

5.2 Privacy Tab

In the Privacy screen, you can maintain security for the logical network and select the device included in the network. See Figure 9.

All HomePlug devices are loaded using a default logical network (network name), which is normally “HomePlug”. In the Privacy screen, you can modify a private network by changing network names and passwords of devices.

Click Use Default or enter HomePlug as the network name, to reset to the

HomePlug network (Public).

Figure 9 Privacy tab

Note:

If the network name changes to anything other than HomePlug, the network type in the main screen is displayed as Private.

12

Set Local Device Only

This button is used to change the network name and password of the local device. If a new network password is entered, all the devices appeared in the Main panel prior to this are no longer present in the new network, effectively making the local devices not to communicate to the devices which are in the old logical network. Click Set

Local Dive Only, the devices previously set up with the same logical network (same network name) appears in the device list.

Set All Devices

This button is used to change the logical network of all devices that appear in the main panel. If these devices whose passwords have been entered for the same logical network, a dialog box appears, indicating successful operation. For devices whose passwords are not entered, a dialog box appears indicating operation failure.

5.3 Diagnostics Tab

The Diagnostics screen shows the system information and history of all remote devices appeared over a period of time. See Figure 10.

The Upper panel shows technical data concerning software and hardware on the host computer that are used to communicate through HomePlug on the power line network. It includes the following:

 Operating platform/version

 Host network name

 User

 MAC address of all NICs (Network interface card) connected to the host

 Identify versions of all Driver DLLs and Libraries used (NDIS) and optionally

 HomePlug chipset manufacturer name (Turbo Only devices)

 MAC Firmware Version (Turbo Only devices)

 MAC addresses of all devices connected locally to the host

 Version of the Configuration Utility

 Vendor

13

Figure 10 Diagnostics tab

The Lower panel displays the history of all remote devices appeared on the computer over a certain period of time. All the devices and the parameters of the devices on the power line network are listed. Devices that are active on the current logical network show a transfer rate in the rate column. Devices on other networks, or devices that no longer exist are shown with a “?” in the rate column. The following remote device information is available from the diagnostics screen:

 Device alias name

 MAC

 Password

 Device last known rate

 Device last known network name

 HomePlug manufacturer name

 Date device last seen on the network

 MAC version

14

The diagnostics information displayed can be saved to a text file for later use, or be printed for reference for a technical support call. Click delete to delete the devices which are no longer part of the network. A dialog window pops up with a confirmation message if the user wants to delete a device whose password has been entered.

5.4 About Tab

The About screen shows the software version and provides a html link to a website, such as www.PowerPacket.com. Clicking the web address, it enters into the web site.

Figure 11 About tab

Preferences

The lower part of the panel displays options for turning the autoscan function on or off.

15

6 How to Use the Security Pushbutton

This section describes how to add new devices or remove old devices from a

HomePlug AV logical network (AVLN) by using a Security (called NMK) pushbutton.

Power LED status indicates the operation progress and result.

6.1 Forming a HomePlug AV Logical Network

When two devices with different NMK values are connected to the same power line, and the user wants them to form a logical network.

Step1 Press the NMK button on device A for less than 3 seconds.

Step2 Press the NMK button on device B for less than 3 seconds. The button on B must be pressed within 1 minute

Step3 Wait for the connection to complete.

The Power LED on both devices blinks evenly at 1-second intervals until the operation succeeds or fails. If the connection succeeds, it illuminates steadily. If an error occurs, the Power LED on the ‘adder’ blinks unevenly until the pushbutton on the ‘adder’ is pressed again or the ‘joiner’ is reset by holding the pushbuttons down for more than 10 seconds.

C

PLC

Figure 12 Forming a HomePlug AV logical network

16

6.2 Joining a Network

In this scenario a network exists, a new device, the ‘joiner’, wants to join the network.

Any device on the existing network can become the ‘adder’.

Step1 Press the pushbutton on the ‘joiner’ for at least 3 seconds.

Step2 Press the pushbutton on any network device for less than 3 seconds, making it the ‘adder’. Please press this pushbutton within 1 minute.

Step3 Wait for the connection to complete.

The Power LED on both devices blinks at 1-second intervals until the process succeeds or fails. It illuminates steadily on success connection. If an error occurs, the

Power LED on the ‘adder’ blinks unevenly until the pushbutton on the ‘adder’ is pressed again or the ‘joiner’ is reset by pressing the pushbutton for more than 10 seconds.

Figure 13 Joining a network

17

6.3 Leaving a Network

A network exists. The user wants to remove one device, the ‘leaver’, from that network. The user wants to remove the device from service altogether or have it join another logical network.

Step1 Press the pushbutton on the ‘leaver’ for at least 10 seconds. The device resets and restarts with a random NMK.

Step2 Wait for the reset to complete.

The Power LED on the ‘leaver’ momentarily extinguishes during reset, blinks during restart, then illuminates steadily. No error occurs.

The user can disconnect the device from the medium or join it to another logical network on the same medium when it is completed.

Figure 14 Leaving a network

18

Appendix A Specifications

Chipset Intellon INT6400

Protocol

System Support

Compliant with HomePlug AV 1.1

Co-existing with existing HomePlug 1.0

Windows 7, Vista, XP

PLC Rate

Modulation Band

200 Mbps

2MHz~30MHz

Modulation Schemes

Encryption

LED Indicators

Buttons

Consumption

Support QAM 1024/256/64/16/8, QPSK, BPSK and ROBO

128 AES

Power :Power on and off

Ethernet: Ethernet link and activity

Data: PLC link and activity

Reset: Restore the default factory settings

Security: Set the membership state

3.5 W

Operating Temperature 0ºC~40ºC

Storage Temperature

Operating Humidity

Storage Humidity

Power Supply

Certifications

Green Standard

Physical

Characteristics

Weight

-10ºC~70ºC

10%~90%, non-condensing

5%~95%, non-condensing

100 V~240 V AC, 50Hz~60Hz

CE, UL, FCC Part 15 Class B

RoHS

L×W×H: 90 mm × 55 mm × 34 mm

108 g

19

Appendix B Acronyms and Abbreviations

AVLN

CCo

CSMA/CA

DAK

DM

IGMP

NEK

NID

NMK

PLC

PIB

STA

TDMA

TEI

TOS

VLAN

AV In-home Logical Network, the AVLAN is the set of STAs that possess the same network

Membership key, every AVLN is managed by a single CCo

Central Coordinator, the CCo is a superset of a

STA which includes terminal equipment identifiers and global link identifiers

Carrier Sense Multiple Access / Collision

Avoidance

Device Access Key

Device Manager

Internet Group Management Protocol

Network Encryption Key

Network ID (Identification)

Network Membership Key

Power Line Communication

Parameter Information Block

Station, a STA in the network with a connection to the power line and being able to source or sink traffic

Time Division Multiple Access

Terminal Equipment Identifier

Type of Service

Virtual Local Area Network

20

Appendix C About QoS

PLC 200AV allows 4 levels of Channel Access Priority (CAP (0 – 3)). The 8 levels of

VLAN Ethernet tags must be mapped to the 4 levels of CAP priority, where CAP 3 is the highest priority and CAP 0 is the lowest. CAP 3 priority is used for voice and network management frames. CAP 2 is used for streaming video and music while

CAP 1 and CAP 0 are used for data.

Default CAP

The Default CAP group allows default priority mapping of packets that do not have a

VLAN tag. Settings are available for unicast (directed to a host).

 IGMP - (default CAP 3) - set the channel access priority for IGMP frames - these are the group management frames, not the stream data.

 Unicast - (default CAP 1) - set the default channel access priority for unicast frames not matching any other classification or mapping.

 IGMP managed Multicast Stream (Fixed to CAP 2) - set the default channel access priority for stream data belonging to a snooped IGMP multicast group.

 Multicast/Broadcast - set the default CAP for multicast frames not in a snooped group and for broadcast frames.

The following are the factory default settings for VLAN Tags and TOS Bits:

VLAN Tag

User priority

Default CAP

Priority

TOS Bit User

Priority

Default CAP

Priority

21

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project