Pricelist

Heating
Pricelist
2014
→ Table of contents
→ Daikin Altherma low temperature split
System Introduction
4
Technical Specifications
6
Pricelist
8
→ Daikin Altherma low temperature monobloc
System Introduction
11
Technical Specifications
12
Pricelist
14
→ Daikin Altherma high temperature
System Introduction
16
Technical Specifications
18
Pricelist
20
→ Daikin Altherma Flex Type
System Introduction
22
Technical Specifications
24
Pricelist
26
→ Daikin heat pump convector
System Introduction
28
Technical Specifications
29
Pricelist
29
→ Daikin solar system
System Introduction
30
Technical Specifications
32
Pricelist
33
▪ NOTES
The pricelist is valid from 1. April 2014. All prior pricelists are not valid anymore. All prices are list prices in Euro and excl. VAT. The Daikin Commercial Terms
and Conditions apply (see last page or http://www.daikin-ce.com). We reserve the right for printing errors and model changes.
2
You and your customer have decided to switch to an energy-efficient heating
system that produces low CO2 emissions. Daikin Altherma is a total heating
and domestic hot water system based on air source heat pump technology.
One that represents a flexible and cost-effective alternative to a fossil fuel boiler.
It also has an option for cooling.*
The inherent energy-efficiency characteristics of Daikin Altherma make it
an ideal solution for reduced energy consumption and low CO2
emissions. Its high- and low-temperature heating systems provide optimal
comfort. Highly energy-efficient heat pumps with advanced compressor
technology transform unused and inexhaustible heat from the surrounding air
into usable heat, either as part of the overall climate-control system or to
heat domestic hot water. Moreover, the system is easy to install.
*The Daikin Altherma cooling option is available for low-temperature heating systems (under floor heating system, heat pump convectors).
3
→ Daikin Altherma low temperature split
COP
up to 4,02
A2/W35
(according to
EN14511)
Best season al
efficiencies,
Perfect fit
providing the highest savings on
running costs and CO2 emissions.
for new builds,
as well as for low-energy houses
High heat pump efficiencies at all outdoor and water
temperatures guarantee low running costs and low CO2
emissions.
NEW: Optimised unit for low heat loads available
The new-build house market in Europe is moving towards
smaller heat loads, due to:
– Growing importance of low-energy houses
– Strengthened legislation on energy consumption in
new residential constructions (e.g. EPBD regulations)
– Decreasing size of new-build houses
– EU member states planning to reach their
20-20-20 targets
High heating capacities enable best efficiencies down to low
outside temperature. The electrical back-up heater assistance is
no longer required or only very limited.
Daikin inverter compressors with high modulation range
provide:
– Higher compressor efficiency in partial load operation.
– Delivered capacities exactly matching the actual heating
demand of the building.
– Obtaining the capacities needed with minimum energy
consumption.
– Less on/off operation, increasing the operation life cycle
of the compressor.
The new Daikin Altherma low temperature is designed to
meet the requirements of newly built and low-energy houses
characterised by low heat loads.
With capacities from 4 to 16kW Daikin Altherma covers 90%
of all new built applications.
Limiting electrical inputs of auxiliary components
contribute to the high seasonal efficiencies:
– Factory-mounted high efficiency circulating pump
already qualifying for future regulations (ErP2015) with
an A-energy label (EEI ≤ 0.23)
– No standby losses of inverter drive PCB, lowering
electricity consumption during standby mode
– No bottom plate heater needed on 4-8kW class
– Low-capacity bottom plate heater on 11-16kW class
(ERLQ-C series), only operating during defrost cycles.
All types of heat emitters are possible:
– Under-floor heating: 25°C  35°C
– Heat pump convector: 35°C  45°C
– Low temperature radiators: 40°C  50°C
Daikin Altherma is suitable for all climates, even
withstanding severe winter conditions.
4
→ Daikin Altherma low temperature split
Integrated
indoor unit:
User interface:
best solution for domestic
hot water for installer & customer
high functionalities, easy to use
Minimised installation space, both in terms of footprint
and height:
– Small footprint with a width
of only 60cm and a depth of 74cm
– The required installation height is
less than 2m
– Sleek design and modern look
74 cm
Easiest and fastest installation, domestic hot water tank included
– Fast installation: the stainless steel domestic hot water
tank is included in the unit, with all connections between
heat pump module and tank factory made.
– All hydraulic components are included.
– Lower installation footprint.
60 cm
Best solution for domestic hot water
heating with high efficiency and high comfort
– 50% less heat loss compared to a standard insulated tank.
– High hot water volumes: 300l at 40°C, enough for
6 showers without any electrical assistance.
Quick and easy commissioning:
– Quick configuration wizard to guide installer through
commissioning process
– Menu-based navigation to fine-tune the basic parameters
– Parameters are up- and downloadable from/to PC
– Actuator test mode to activate all wired components
one by one
– Automatic screed-drying function
Room temperature control functionality:
The user interface itself is equipped with a temperature sensor
and can be directly used as a rom thermostat, resulting in more
stable room temperatures, increased efficiency and operation
life cycle.
User-friendly with intuitive control:
– The large graphical interface allows an intuitive and
self-explanatory menu
– Provides additional information such as the energy
consumption and heat production of the system
Graphical screen with backlight
Wall-mounted indoor unit including all hydraulic components.
On/Off
Error info
Home
Menu back
Confirm
5
Navigational buttons
→ Daikin Altherma low temperature split
▪ Technical specifications
OUTDOOR UNIT
ERLQ004CV3
ERLQ006CV3
ERLQ008CV3
Heating capacity Min.
kW
1,80 1
1,801
1,801
Nom.
Max.
Cooling capacity Nom.
COP nom.
EER nom.
Dimensions
Unit
Operation range Heating
Cooling
Domestic hot water
Sound pressure Heating
level*
Cooling
Power supply (phase/voltage)
kW
kW
kW
4,401 / 3,272
5,121
5,003 / 4,174
5,041 / 4,022
3,373 / 2,324
735x832x307
-25~25
10~43
-25~35
48
48
1~/230V
6,001 / 4,582
8,351
6,763 / 4,844
4,741 / 3,682
3,453 / 2,344
735x832x307
-25~25
10~43
-25~35
48
49
1~/230V
7,401 / 5,802
10,021
6,863 / 5,364
4,451 / 3,532
3,423 / 2,294
735x832x307
-25~25
10~43
-25~35
49
50
1~/230V
H xW xD
Min.~Max.
Min.~Max.
Min.~Max.
Nom.
Nom.
mm
°C
°C
°C
dBA
dBA
HEATING ONLY
INDOOR UNIT - WALL MOUNTED
EHBH04C3V
EHBH08C3V
EHBH08C9W
Dimensions
Unit
H xW xD
mm
Operation range Heating
Water side Min.~Max. °C
Domestic hot water Water side Min.~Max. °C
Sound pressure level* Nom.
dBA
Power supply (phase/voltage)
890x480x344
15~55
25~80
26
1~/230V
890x480x344
15~55
25~80
26
1~/230V / 3~/400V
EHBX04C3V
EHBX08C3V
EHBX08C9W
890x480x344
15~55
5~22
25~80
26
1~/230V
890x480x344
15~55
5~22
25~80
26
1~/230V / 3~/400V
EHVH04S18C3V
EHVH08S18C3V
EHVH08S26C9W
1.732x600x728
15~55
25~80
28
1~/230V
1.732x600x728
15~55
25~80
28
1~/230V / 3~/400V
EHVX04S18C3V
EHVX08S18C3V
EHVX08S26C9W
1.732x600x728
15~55
5~22
25~80
28
1~/230V
1.732x600x728
15~55
5~22
25~80
28
1~/230V / 3~/400V
HEATING & COOLING
INDOOR UNIT - WALL MOUNTED
Dimensions
Unit
Operation range Heating
Cooling
Domestic hot water
Sound pressure level* Nom.
Power supply (phase/voltage)
H xW xD
mm
Water side Min.~Max. °C
Water side Min.~Max. °C
Water side Min.~Max. °C
dBA
HEATING ONLY
INDOOR UNIT - FLOORSTANDING
Dimensions
Unit
H xW xD
mm
Operation range Heating
Water side Min.~Max. °C
Domestic hot water Water side Min.~Max. °C
Sound pressure level* Nom.
dBA
Power supply (phase/voltage)
HEATING & COOLING
INDOOR UNIT - FLOORSTANDING
Dimensions
Unit
Operation range Heating
Cooling
Domestic hot water
Sound pressure level* Nom.
Power supply (phase/voltage)
H xW xD
mm
Water side Min.~Max. °C
Water side Min.~Max. °C
Water side Min.~Max. °C
dBA
6
→ Daikin Altherma low temperature split
ERLQ11CV3 / ERLQ11CW1
ERLQ14CV3 / ERLQ14CW1
ERLQ16CV3 / ERLQ16CW1
–
11,201 / 8,562
11,381
15,053 / 11,724
4,601 / 3,602
3,323 / 2,724
1.345x900x320
-25~35
10~46
-20~35
51
50
1~/230V / 3~/400V
–
14,501 / 10,302
14,551
16,063 / 12,554
4,301 / 3,452
2,963 / 2,474
1.345x900x320
-25~35
10~46
-20~35
51
52
1~/230V / 3~/400V
–
16,001 / 11,102
16,101
16,763 / 13,124
4,251 / 3,352
2,723 / 2,294
1.345x900x320
-25~35
10~46
-20~35
52
54
1~/230V / 3~/400V
EHBH16C3V
EHBH16C9W
890x480x344
25~55
25~80
33
1~/230V
890x480x344
25~55
25~80
33
3~/400V
EHBX16C3V
EHBX16C9W
890x480x344
15~55
5~22
25~80
33
1~/230V
890x480x344
15~55
5~22
25~80
33
3~/400V
EHVH16S18BC3V
EHVH16S26C9W
1.732x600x728
15~55
25~80
33
1~/230V
1.732x600x728
15~55
25~80
33
3~/400V
EHVX16S18C3V
EHVX16S26C9W
1.732x600x728
15~55
5~22
25~80
33
1~/230V
1.732x600x728
15~55
5~22
25~80
33
3~/400V
*Measured in 1m distance from the unit.
(1) EW 30°C; LW 35°C; ambient conditions: 7°CDB/6°CWB
(2) EW 30°C; LW 35°C; ambient conditions: 2°CDB/1°CWB
(3) EW 23°C; LW18°C; ambient conditions: 35°C
(4) EW 12°C; LW 7°C; ambient conditions 35°C
7
→ Daikin Altherma low temperature split
▪ Pricelist
Daikin Altherma is a low temperature, inverter driven air to water split heat pump system. The outdoor unit is connected
to the indoor unit (wallmounted or floorstanding) with refrigerant piping. The heat pump system can be used for space
heating, space cooling and domestic hot water production.
Daikin Altherma Low Temperature Outdoor Unit
Inverter Split Heat pump outdoor unit with nominal capacities from 4 to 8 kW. Nominal capacity is measured at A7/W35**.
PRICE HUF
Daikin Altherma 4 kW outdoor unit*
Daikin Altherma 6 kW outdoor unit
Daikin Altherma 8 kW outdoor unit
447.300,–
469.500,–
641.400,–
ERLQ004CV3
ERLQ006CV3
ERLQ008CV3
Power Supply 1~ 230V
Power Supply 1~ 230V
Power Supply 1~ 230V
Daikin Altherma wallmounted indoor unit for heating only applications.
All basic necessary hydraulic components included.
Wallmounted indoor unit 4kW with 3kW BUH*
Wallmounted indoor unit 6-8 kW with 3kW BUH
Wallmounted indoor unit 6-8kW with 3-9 kW BUH
EHBH04C3V
EHBH08C3V
EHBH08C9W
PRICE HUF
Electrical Backup Heater 1~ 230V
Electrical Backup Heater 1~ 230V
Electrical Backup Heater 1~ 230V or 3~ 400V
Daikin Altherma wallmounted indoor unit for heating & cooling applications.
All basic necessary hydraulic components included.
Wallmounted indoor unit 4kW with 3kW BUH*
Wallmounted indoor unit 6-8 kW with 3kW BUH
Wallmounted indoor unit 6-8kW with 3-9 kW BUH
EHBX04C3V
EHBX08C3V
EHBX08C9W
726.100,–
762.500,–
799.500,–
PRICE HUF
Electrical Backup Heater 1~ 230V
Electrical Backup Heater 1~ 230V
Electrical Backup Heater 1~ 230V or 3~ 400V
789.500,–
829.000,–
865.700,–
Daikin Altherma Indoor unit (floorstanding with domestic hot water tank) for heating only applications.
All basic necessary hydraulic components included.
PRICE HUF
Floorstanding indoor unit 4kW with 3kW BUH & 180L Tank*
EHVH04S18C3V
Floorstanding indoor unit 6-8 kW with 3kW BUH & 180L Tank EHVH08S18C3V
Floorstanding indoor unit 6-8kW with 3-9 kW BUH & 260L Tank EHVH08S26C9W
1.041.900,–
1.078.300,–
1.156.100,–
Electrical Backup Heater 1~ 230V
Electrical Backup Heater 1~ 230V
Electrical Backup Heater 1~ 230V or 3~ 400V
Daikin Altherma Indoor unit (floorstanding with domestic hot water tank) for heating & cooling applications.
All basic necessary hydraulic components included.
PRICE HUF
Floorstanding indoor unit 4kW with 3kW BUH & 180L Tank*
Floorstanding indoor unit 6-8 kW with 3kW BUH & 180L Tank
Floorstanding indoor unit 6-8kW with 3-9 kW BUH & 260L Tank
1.105.300,–
1.144.800,–
1.222.300,–
EHVX04S18C3V
EHVX08S18C3V
EHVX08S26C9W
Electrical Backup Heater 1~ 230V
Electrical Backup Heater 1~ 230V
Electrical Backup Heater 1~ 230V or 3~ 400V
Daikin Altherma Low Temperature Outdoor Unit
Inverter Split Heat pump outdoor unit with nominal capacities from 11 to 16 kW. Nominal capacity is measured at A7/W35**
PRICE HUF
Daikin Altherma 11 kW outdoor unit
Daikin Altherma 14 kW outdoor unit
Daikin Altherma 16 kW outdoor unit
850.300,–
1.016.500,–
1.154.500,–
ERLQ011CV3
ERLQ014CV3
ERLQ016CV3
Power Supply 1~ 230V
Power Supply 1~ 230V
Power Supply 1~ 230V
Daikin Altherma Low Temperature Outdoor Unit
Inverter Split Heat pump outdoor unit with nominal capacities from 11 to 16 kW. Nominal capacity is measured at A7/W35**.
PRICE HUF
Daikin Altherma 11 kW outdoor unit
Daikin Altherma 14 kW outdoor unit
Daikin Altherma 16 kW outdoor unit
943.800,–
1.115.300,–
1.271.500,–
ERLQ011CW1
ERLQ014CW1
ERLQ016CW1
Power Supply 3~ 400V
Power Supply 3~ 400V
Power Supply 3~ 400V
Daikin Altherma wallmounted indoor unit for heating only applications.
All basic necessary hydraulic components included.
Wallmounted indoor unit 11-16 kW with 3 kW BUH
Wallmounted indoor unit 11-16 kW with 3-9 kW BUH
EHBH16C3V
EHBH16C9W
PRICE HUF
Electrical Backup Heater 1~ 230V
Electrical Backup Heater 1~ 230V or 3~ 400V
Daikin Altherma wallmounted indoor unit for heating & cooling applications.
All basic necessary hydraulic components included.
Wallmounted indoor unit 11-16 kW with 3 kW BUH
Wallmounted indoor unit 11-16 kW with 3-9 kW BUH
EHBX16C3V
EHBX16C9W
873.800,–
916.500,–
PRICE HUF
Electrical Backup Heater 1~ 230V
Electrical Backup Heater 1~ 230V or 3~ 400V
950.000,–
992.400,–
Daikin Altherma Indoor unit (floorstanding with domestic hot water tank) for heating only applications.
All basic necessary hydraulic components included.
PRICE HUF
Floorstanding indoor unit 11-16 kW with 3kW BUH & 180L Tank EHVH16S18C3V
Floorstanding indoor unit 11-16 kW with 3-9 kW BUH & 260 L Tank EHVH16S26C9W
1.189.700,–
1.273.100,–
Electrical Backup Heater 1~ 230V
Electrical Backup Heater 1~ 230V or 3~ 400V
Daikin Altherma Indoor unit (floorstanding with domestic hot water tank) for heating & cooling applications.
All basic necessary hydraulic components included.
PRICE HUF
Floorstanding indoor unit 11-16 kW with 3kW BUH & 180L Tank EHVX16S18C3V
Floorstanding indoor unit 11-16 kW with 3-9 kW BUH & 260 L Tank EHVX16S26C9W
1.265.900,–
1.349.000,–
Electrical Backup Heater 1~ 230V
Electrical Backup Heater 1~ 230V or 3~ 400V
* The 4kW outdoor ERLQ004CV3 unit can only be combined with a 4kW indoor unit (either wallmounted or floorstanding)!
** Ta DB/WB 7°C / 6°C - LWC 35°C (DT = 5K)
8
→ Daikin Altherma low temperature split
Applicable for:
Additional controllers
4-8kW
EKRUCL1
EKRUCL2
Controller
Controller
●
●
User interface with languages EN, CZ, TU, PT, SW, NO
User interface with languages EN, FR, DE, IT, NL, ES
●
●
4-8kW
Drainpan for outdoor unit
(exl. drainpan heater)
Heater tape for outdoor unit drainpan
Remote temperature sensor for outdoor unit
U-beams for outdoor unit
Remote indoor sensor
PC cable
Drain pan kit for indoor unit
Wired room thermostat
Wireless room thermostat
Thermostat external sensor
Digital I/O PCB
Demand PCB
Demand PCB
Solar Kit
Electricity meter
Electricity meter
Domestic hot water connection kit for EKHWP300B H/O
Domestic hot water connection kit for EKHWP500B H/O
Domestic hot water connection kit for EKHWP500B H/C
Electrical Booster Heater
EKDP008C
EKDPH008C
EKRSC1
EKFT008CA
KRCS01-1
EKPCCAB2
EKHBDPC2
EKRTWA
EKRTR
EKRTETS
EKRP1HBA
EKRP1AHT
KRP58M51
EKSOLHW
K.ELECMETV
K.ELECMETW
EKDVCPLT3H/X
EKDVCPLT5H
EKDVCPLT5X
EKBH3S
●
Collect water from defrost cycle and drain via central hole to remote location.
If installed additional heater tape EKDPH00bC is mandatory!
Heater tape to install in central hole of drain pan to prevent ice blockage
Ambient temperature measurement remotely from outdoor unit
Beams to mount outdoor unit on (height 25cm)
Temperature measurement remotely from user interface
Cable to upload field settings from PC to unit
Collect and drain condensate during cooling operation
Wired Digital Room Thermostat
Wireless Digital Room Thermostat
Temperature measurement remotely from wireless room thermostat (e.g. floor temperature)
Remote alarm / operation status
Power consumption limitation with 4 digital inputs on hydrobox
Power consumption limitation via outdoor unit
Heat exchanger to connect Daikin solar system to EKHWS and EKHWE DHW tank
Single phase electricity meter
Three phase electricity meter
Connection kit for LT 4-8kW in combination with EKHWP300B
Connection kit for LT 4-16kW heating only in combination with EKHWP500B
Connection kit for LT 4-16kW heating & cooling in combination with EKHWP500B
Electrical booster heat for EKHWP-B tanks
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
4-8kW
Stainless Steel Domestic Hot Water Tank 150L
Wallbracket for 150L stainless steel tank
Stainless Steel Domestic Hot Water Tank 200L
Stainless Steel Domestic Hot Water Tank 200L
Stainless Steel Domestic Hot Water Tank 300L
Stainless Steel Domestic Hot Water Tank 300L
Enameled Domestic Hot Water Tank 150L
Enameled Domestic Hot Water Tank 150L (wallmounted)
Enameled Domestic Hot Water Tank 200L
Enameled Domestic Hot Water Tank 200L
Enameled Domestic Hot Water Tank 300L
Enameled Domestic Hot Water Tank 300L
Pressureless 300L Domestic Hot Water Tank
Pressureless 500L Domestic Hot Water Tank
EKHWS150B3V3
EKWBSWW150
EKHWS200B3V3
EKHWS200B3Z2
EKHWS300B3V3
EKHWS300B3Z2
EKHWE150A3V3
EKHWET150A3V3
EKHWE200A3V3
EKHWE200A3Z2
EKHWE300A3V3
EKHWE300A3Z2
EKHWP300B
EKHWP500B
●
●
●
●
●
●
●
●
●
●
●
●
●
●
incl. 3kW booster heater 1~ 230V, height 900mm, diameter 580mm, weight 37kg
incl. 3kW booster heater 1~ 230V, height 1150mm, diameter 580mm, weight 45kg
incl. 3kW booster heater 2~ 400V, height 1150mm, diameter 580mm, weight 45kg
incl. 3kW booster heater 1~ 230V, height 1600mm, diameter 580mm, weight 59kg
incl. 3kW booster heater 2~ 400V, height 1600mm, diameter 580mm, weight 59kg
incl. 3kW booster heater 1~ 230V, height 1205mm, diameter 545mm, weight 80kg
incl. 3kW booster heater 1~ 230V, height 1205mm, diameter 545mm, weight 82kg
incl. 3kW booster heater 1~ 230V, height 1580mm, diameter 545mm, weight 104kg
incl. 3kW booster heater 2~ 400V, height 1580mm, diameter 545mm, weight 104kg
incl. 3kW booster heater 1~ 230V, height 1572mm, diameter 660mm, weight 140kg
incl. 3kW booster heater 2~ 400V, height 1572mm, diameter 660mm, weight 140kg
Pressureless hygienic domestic hot water tank with solar option for 4-8 kW LT heat pumps
Pressureless hygienic domestic hot water tank with solar option for 4-16kW LT heat pumps
PRICE HUF
11-16kW
47.700,–
71.800,–
24.800,–
33.200,–
23.500,–
71.800,–
43.000,–
38.000,–
71.700,–
4.700,–
41.100,–
41.100,–
56.900,–
230.500,–
49.300,–
103.100,–
76.300,–
149.900,–
198.900,–
97.600,–
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Applicable for:
Domestic Hot Water Tanks (can be used for solar option)
PRICE HUF
38.300,–
38.300,–
Applicable for:
Options & Accessories
▪
11-16kW
PRICE HUF
11-16kW
●
●
●
●
●
●
●
●
●
●
●
●
305.500,–
84.400,–
315.800,–
315.800,–
356.600,–
356.600,–
255.000,–
276.600,–
262.800,–
262.800,–
297.000,–
297.000,–
546.000,–
664.200,–
●
Combinations
INDOOR UNIT
Wallmounted
OUTDOOR UNIT
EHBH04C3V
EHBX04C3V
ERLQ004CV3
ERLQ006CV3
ERLQ008CV3
ERLQ011CV3
ERLQ014CV3
ERLQ016CV3
ERLQ011CW1
ERLQ014CW1
ERLQ016CW1
●
–
–
–
–
–
–
–
–
Floorstanding
Wallmounted
EHBH08C3V
EHBX08C3V
EHBH08C9W
EHBX08C9W
EHVH04S18C3V EHVH08S18C3V EHVH08S26C9W
EHVX04S18C3V EHVX08S18C3V EHVX08S26C9W
EHBH16C3V
EHBX16C3V
EHBH16C9W
EHBX16C9W
–
●
●
–
–
–
–
–
–
–
●
●
–
–
–
–
–
–
–
●
●
–
–
–
–
–
–
–
–
–
●
●
●
●
●
●
–
–
–
●
●
●
●
●
●
●
–
–
–
–
–
–
–
–
9
–
●
●
–
–
–
–
–
–
Floorstanding
EHVH16S18C3V EHVH16S26C9W
EHVX16S18C3V EHVX16S26C9W
–
–
–
●
●
●
●
●
●
–
–
–
●
●
●
●
●
●
10
→ Daikin Altherma low temperature monobloc
Monobloc system
Everything combined in one outdoor unit
In addition to Daikin Altherma split systems, Daikin has introduced a monobloc
version in which all hydraulic parts are located within the outdoor unit.
In this system, the water pipes, rather than the refrigerant pipes, run indoors
from the outdoor unit, making installation much quicker and easier
for the domestic installer.
Available capacities for monobloc: 11, 14, 16 kW
Domestic hot water
Solar connection (optional)
Heat pump convector
Outdoor unit:
11, 14 and 16 kW
Under floor heating
11
→ Daikin Altherma low temperature monobloc
▪ Technical specifications
HEATING ONLY
EDLQ011BB6V3
Heating capacity
Power input
COP
Dimensions
Weight
Hydraulic
component
SINGLE
PHASE
Nom.
Heating
Nom.
Unit
Height X Width X Depth
Unit
Back-up
Type
heater current Power
Phase/Frequency/
supply
Voltage
Operation range
Heating
Ambient
Min.~Max.
Water side Min.~Max.
Domestic hot Ambient
Min.~Max.
water
Water side Min.~Max.
Refrigerant
Type
Charge
Sound power level Heating
Nom.
Sound pressure level Heating
Nom.
Compressor
Main power
Name
component
supply
Phase
Frequency
Voltage
EDLQ014BB6V3
11,201 / 8,112
2,561 / 2,572
4,381 / 3,162
kW
kW
14,001 / 9,722
3,291 / 3,122
4,251 / 3,122
1.418 X 1.435 X 382
180
6V3
mm
kg
~/Hz/V
16,001 / 10,692
3,881 / 3,442
4,121 / 3,112
1~/50/230
°C
°C
°C
°C
kg
dBA
dBA
EDLQ016BB6V3
-20~35
15 ~55
-20~43
25~80
R-410A
2,95
65
64
51
66
52
V3
1~
50
230
Hz
V
(1) cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (nom. values according to EN14511)
(2) cooling Ta 35°C - LWE 7°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) (nom. values according to EN14511)
HEATING ONLY
EDLQ011BB6W1
Heating capacity
Power input
COP
Dimensions
Weight
Hydraulic
component
THREE
PHASE
Nom.
Heating
Nom.
Unit
Height X Width X Depth
Unit
Back-up
Type
heater current Power
Phase/Frequency/
supply
Voltage
Operation range
Heating
Ambient
Min.~Max.
Water side Min.~Max.
Domestic hot Ambient
Min.~Max.
water
Water side Min.~Max.
Refrigerant
Type
Charge
Sound power level Heating
Nom.
Sound pressure level Heating
Nom.
Compressor
Main power
Name
component
supply
Phase
Frequency
Voltage
11,201 / 8,112
2,601 / 2,612
4,311 / 3,112
kW
kW
mm
kg
~/Hz/V
Hz
V
14,001 / 9,722
3,301 / 3,132
4,241 / 3,112
1.418 X 1.435 X 382
180
6W1
64
49
-25~35
15 ~55
-25~43
25~80
R-410A
2,95
65
51
W1
3N~
50
400
(1) cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (nom. values according to EN14511)
(2) cooling Ta 35°C - LWE 7°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) (nom. values according to EN14511)
12
EDLQ016BB6W1
16,001 / 10,692
3,811 / 3,442
4,201 / 3,112
3~/50/400
°C
°C
°C
°C
kg
dBA
dBA
EDLQ014BB6W1
66
53
→ Daikin Altherma low temperature monobloc
HEATING & COOLING
Heating capacity
Cooling capacity
Power input
Nom.
Nom.
Cooling
Heating
Nom.
Nom.
COP
EER
Dimensions
Weight
Hydraulic
component
SINGLE
PHASE
Unit
Height X Width X Depth
Unit
Back-up
Type
heater current Power
Phase/Frequency/
supply
Voltage
Operation range Heating
Ambient
Min.~Max.
Water side Min.~Max.
Cooling
Ambient
Min.~Max.
Water side Min.~Max.
Domestic hot Ambient
Min.~Max.
water
Water side Min.~Max.
Refrigerant
Type
Charge
Sound power level Heating
Nom.
Cooling
Nom.
Sound pressure
Heating
Nom.
level
Cooling
Nom.
Compressor
Main power
Name
component
supply
Phase
Frequency
Voltage
kW
kW
kW
kW
EBLQ011BB6V3
EBLQ014BB6V3
EBLQ016BB6V3
11,201 / 8,112
12,851 / 10,002
3,871 / 3,692
2,561 / 2,572
4,381 / 3,162
3,321 / 2,712
14,001 / 9,722
15,991 / 12,502
5,751 / 5,392
3,291 / 3,122
4,251 / 3,122
2,781 / 2,322
1.418 X 1.435 X 382
180
6V3
16,001 / 10,692
16,731 / 13,102
6,361 / 5,932
3,881 / 3,442
4,121 / 3,112
2,631 / 2,212
mm
kg
~/Hz/V
1~/50/230
°C
°C
°C
°C
°C
°C
kg
dBA
dBA
dBA
dBA
-20~35
15~55
10~46
5~22
-20~43
25~80
R-410A
2,95
65
66
64
65
5
50
Hz
V
52
V3
1~
50
230
66
69
52
54
(1) cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)(nom. values according to EN14511)
(2) cooling Ta 35°C - LWE 7°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) (nom. values according to EN14511)
HEATING & COOLING
Heating capacity
Cooling capacity
Power input
COP
EER
Dimensions
Weight
Hydraulic
component
THREE
PHASE
Nom.
Nom.
Cooling
Heating
Nom.
Nom.
Unit
Height X Width X Depth
Unit
Back-up
Type
heater current Power
Phase/Frequency/
supply
Voltage
Operation range Heating
Ambient
Min.~Max.
Water side Min.~Max.
Cooling
Ambient
Min.~Max.
Water side Min.~Max.
Domestic hot Ambient
Min.~Max.
water
Water side Min.~Max.
Refrigerant
Type
Charge
Sound power level Heating
Nom.
Cooling
Nom.
Sound pressure
Heating
Nom.
level
Cooling
Nom.
Compressor
Main power
Name
component
supply
Phase
Frequency
Voltage
kW
kW
kW
kW
EBLQ011BB6W1
EBLQ014BB6W1
EBLQ016BB6W1
11,201 / 8,112
12,851 / 10,002
3,871 / 3,692
2,601 / 2,612
4,311 / 3,112
3,321 / 2,712
14,001 / 9,722
15,991 / 12,502
5,401 / 5,062
3,301 / 3,132
4,241 / 3,112
2,961 / 2,472
1.418 X 1.435 X 382
180
6W1
16,001 / 10,692
16,731 / 13,102
6,151 / 5,752
3,811 / 3,442
4,201 / 3,112
2,721 / 2,282
mm
kg
~/Hz/V
3~/50/400
°C
°C
°C
°C
°C
°C
kg
dBA
dBA
dBA
dBA
Hz
V
64
65
49
50
-25~35
15~55
10~46
5~22
-25~43
25~80
R-410A
2,95
65
66
51
52
W1
3N~
50
400
(1) cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (nom. values according to EN14511)
(2) cooling Ta 35°C - LWE 7°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) (nom. values according to EN14511)
13
66
69
53
54
→ Daikin Altherma low temperature monobloc
▪ Pricelist
Daikin Altherma monobloc is designed as a compact unit, including
refrigeration cycle and all necessary parts of the water cycle in the units
casing.
Daikin Altherma monobloc simply has to be connected to water pipings,
without the need for refrigeration piping done by the installer.
Beside hydraulic parts such as water pump, expansion vessel, safety valve,
water filter and flow switch monobloc also includes a 6 kW factory mounted
backup heater, which can be reduced during commissioning to a minimum
of 2 kW (400V heater) or 3 kW (230V heater).
Daikin Altherma low temperature monobloc heating only
Inverter monobloc heat pump with nominal capacities from 11 to 16 kW. Nominal capacity is measured at A7/W35.
PRICE HUF
Daikin
Daikin
Daikin
Daikin
Daikin
Daikin
1.862.800,–
2.045.600,–
2.198.100,–
2.027.400,–
2.222.500,–
2.400.000,–
Altherma
Altherma
Altherma
Altherma
Altherma
Altherma
11kW Monobloc 230V
14kW Monobloc 230V
14kW Monobloc 230V
11kW Monobloc 400V
14kW Monobloc 400V
14kW Monobloc 400V
EDLQ011BB6V3
EDLQ014BB6V3
EDLQ016BB6V3
EDLQ011BB6W1
EDLQ014BB6W1
EDLQ016BB6W1
6kW
6kW
6kW
6kW
6kW
6kW
BUH, Power
BUH, Power
BUH, Power
BUH, Power
BUH, Power
BUH, Power
Supply
Supply
Supply
Supply
Supply
Supply
1~ 230V
1~ 230V
1~ 230V
3~ 400V
3~ 400V
3~ 400V
Daikin Altherma low temperature monobloc heating & cooling
Inverter monobloc heat pump with nominal capacities from 11 to 16 kW. Nominal capacity is measured at A7/W35.
PRICE HUF
Daikin
Daikin
Daikin
Daikin
Daikin
Daikin
1.942.400,–
2.125.300,–
2.277.400,–
2.107.100,–
2.301.900,–
2.479.400,–
Altherma
Altherma
Altherma
Altherma
Altherma
Altherma
11kW Monobloc 230V
14kW Monobloc 230V
14kW Monobloc 230V
11kW Monobloc 400V
14kW Monobloc 400V
14kW Monobloc 400V
EBLQ011BB6V3
EBLQ014BB6V3
EBLQ016BB6V3
EBLQ011BB6W1
EBLQ014BB6W1
EBLQ016BB6W1
14
6kW
6kW
6kW
6kW
6kW
6kW
BUH, Power
BUH, Power
BUH, Power
BUH, Power
BUH, Power
BUH, Power
Supply
Supply
Supply
Supply
Supply
Supply
1~ 230V
1~ 230V
1~ 230V
3~ 400V
3~ 400V
3~ 400V
→ Daikin Altherma low temperature monobloc
Applicable for:
11-16kW
Options & accessories
Wired room thermostat
Wireless room thermostat
Digital I/O PCB
Thermostat external sensor
EKRTWA
EKRTR
EKRP1HBA
EKRTETS
Solar Kit
Domestic hot water connection kit for
EKHWP500B H/O
Domestic hot water connection kit for
EKHWP500B H/C
Electrical Booster Heater
EKSOLHW
EKDVCPLT5H
EKDVCPLT5X
EKBH3S
Wired Digital Room Thermostat
Wireless Digital Room Thermostat
Remote alarm / operation status / …
Temperature measurement remotely from wireless
room thermostat (e.g. floor temperature)
Heat exchanger to connect Daikin solar system to EKHWS and EKHWE DHW tank
Connection kit for EDLQ heating only models
in combination with EKHWP500B
Connection kit for EBLQ heating & cooling models
in combination with EKHWP500B
Electrical booster heat for EKHWP-B tanks
●
●
Applicable for:
11-16kW
Domestic hot water tanks (can be used for solar option)
Stainless Steel Domestic Hot Water Tank 150L
Wallbracket for 150L stainless steel tank
Stainless Steel Domestic Hot Water Tank 200L
Stainless Steel Domestic Hot Water Tank 200L
Stainless Steel Domestic Hot Water Tank 300L
Stainless Steel Domestic Hot Water Tank 300L
Enameled Domestic Hot Water Tank 150L
Enameled Domestic Hot Water Tank 150L
(wallmounted)
Enameled Domestic Hot Water Tank 200L
Enameled Domestic Hot Water Tank 200L
Enameled Domestic Hot Water Tank 300L
Enameled Domestic Hot Water Tank 300L
Pressureless 500L Domestic Hot Water Tank
●
●
●
●
●
●
EKHWS150B3V3
EKWBSWW150
EKHWS200B3V3
EKHWS200B3Z2
EKHWS300B3V3
EKHWS300B3Z2
EKHWE150A3V3
EKHWET150A3V3
incl. 3kW booster heater 1~ 230V, height 900mm, diameter 580mm, weight 37kg
EKHWE200A3V3
EKHWE200A3Z2
EKHWE300A3V3
EKHWE300A3Z2
EKHWP500B
incl. 3kW booster heater 1~ 230V, height 1580mm, diameter 545mm, weight 104kg
incl. 3kW booster heater 2~ 400V, height 1580mm, diameter 545mm, weight 104kg
incl. 3kW booster heater 1~ 230V, height 1572mm, diameter 660mm, weight 140kg
incl. 3kW booster heater 2~ 400V, height 1572mm, diameter 660mm, weight 140kg
Pressureless hygienic domestic hot water tank with solar option
incl. 3kW booster
incl. 3kW booster
incl. 3kW booster
incl. 3kW booster
incl. 3kW booster
incl. 3kW booster
heater 1~ 230V, height 1150mm, diameter
heater 2~ 400V, height 1150mm, diameter
heater 1~ 230V, height 1600mm, diameter
heater 2~ 400V, height 1600mm, diameter
heater 1~ 230V, height 1205mm, diameter
heater 1~ 230V, height 1205mm, diameter
15
580mm, weight 45kg
580mm, weight 45kg
580mm, weight 59kg
580mm, weight 59kg
545mm, weight 80kg
545mm, weight 82kg
●
●
●
●
●
●
●
●
●
●
●
●
●
PRICE HUF
38.000,–
71.700,–
41.100,–
4.700,–
230.500,–
149.900,–
198.900,–
97.600,–
PRICE HUF
305.500,–
84.400,–
315.800,–
315.800,–
356.600,–
356.600,–
255.000,–
276.600,–
262.800,–
262.800,–
297.000,–
297.000,–
664.200,–
→ Daikin Altherma high temperature
For replacement
of traditional boilers
Daikin Altherma high temperature system offers heating and domestic hot
water for your home. This system can perfectly replace a traditional boiler and
connect to the existing piping. Daikin Altherma high temperature is therefore
the ideal solution for renovations. The split system consists of an outdoor unit and
an indoor unit and can be completed with solar connection.
Solar connection (optional)
Domestic hot
water tank
Outdoor unit
Indoor unit
16
→ Daikin Altherma high temperature
Split system
A split system consists of an outdoor unit and an indoor unit
The Daikin Altherma outdoor unit includes a heat pump that extracts heat from the outside air resulting in nearly 2/3 of all
usable heat coming from a sustainable and free source.
The outdoor unit extracts heat from the ambient outdoor air. This heat is transferred to the indoor unit via refrigerant piping.
The indoor unit receives the heat from the outdoor unit and further increases the temperature, allowing water temperatures
up to 80°C for heating through radiators and for domestic hot water use. Daikin’s unique cascade compressor approach
to the heat pumps (one in the outdoor unit/one in the indoor unit) means optimum comfort at even the coldest outdoor
temperatures, without the need for an electric back-up heater.
Daikin Altherma high temperature heats up to 3 times more efficiently than a traditional heating system based on fossil
fuels or electricity. A lower running cost is thus achieved, while you can still enjoy a stable and pleasant level of comfort.*
* COP (Coefficient of Performance) of up to 3.08
Domestic hot water tank
Daikin Altherma’s high water temperature is ideal for heating domestic hot water without the need for an additional electric
heater. Rapid heating of domestic hot water also means smaller heaters are needed. For a family of approximately 4 people,
the standard tank is the best solution. Should you require more hot water, a larger tank is also available.
Heat emitters
Solar connection
The Daikin Atherma high temperature system is designed
to work with high-temperature radiators, which come in
various sizes and formats to suit the interior design as well as
the heating requirement. The radiators can be individually
controlled or they can be regulated by the central heating
control programme.
The Daikin Altherma high temperature heating system can
optionally use solar energy for hot water production.
If the solar energy is not required immediately, the purposebuilt hot water tank (EKHWP) can store large quantities of
heated water for up to a day for later use as domestic hot
water or for heating.
17
→ Daikin Altherma high temperature
▪ Technical specifications
OUTDOOR UNIT
ERRQ011AV1
Heating capacity Nom.
Power input
Heating
Nom.
COP
Dimensions
Unit
H xW xD
Weight
Unit
Operation
Heating
Min.~Max.
range
Domestic hot water Min.~Max.
Refrigerant
Type
Charge
Sound power level Heating
Nom.
Sound pressure level Heating
Nom.
Power supply
Name/Phase/Frequency/Voltage
Current
Recommended fuses
kW
kW
1
2
ERRQ014AV1
1
2
11 / 11
3,57 1 / 4,40 2
3,08 1 / 2,50 2
14 / 14
4,66 1 / 5,65 2
3,00 1 / 2,48 2
68
52
69
53
1~/50/220-440
25
mm
kg
°CWB
°CDB
kg
dBA
dBA
Hz/V
A
ERRQ016AV1
1
ERRQ011AY1
2
1
2
16 / 16
11 / 11
5,57 1 / 6,65 2
3,57 1 / 4,402
2,88 1 / 2,41 2
3,08 1 / 2,50 2
1.345x900x320
120
-20~20
-20~35
R-410A
4,5
71
68
55
52
ERRQ014AY1
1
2
ERRQ016AY1
14 / 14
4,66 1 / 5,65 2
3,00 1 / 2,48 2
16 1 / 16 2
5,57 1 / 6,65 2
2,88 1 / 2,41 2
69
53
3~/50/380-415
16
71
55
(1) EW 55ºC; LW 65ºC; Dt 10ºC; ambient conditions: 7ºCDB/6ºCWB
(2) EW 70ºC; LW 80ºC; Dt 10ºC; ambient conditions: 7ºCDB/6ºCWB
INDOOR UNIT - floor standing
Casing
Dimensions
Weight
Operation
range
EKHBRD011ACV1 EKHBRD014ACV1 EKHBRD016ACV1 EKHBRD011ACY1 EKHBRD014ACY1 EKHBRD016ACY1
Colour
Material
Unit
Unit
Heating
Metallic grey
H xW xD
Ambient
Water side
Domestic hot Ambient
water
Water side
Refrigerant
Type
Charge
Sound pressure Nom.
level
Night quiet mode Level 1
Power supply
Name
Phase
Frequency
Voltage
Current
Recommended fuses
Min.~Max.
Min.~Max.
Min.~Max.
Min.~Max.
mm
kg
°C
°C
°CDB
°C
kg
dBA
dBA
Hz
V
A
Precoated sheet metal
705x600x695
144,25
147,25
-20~20
25~80
-20~35
25~80
R-134a
3,2
43 / 46 45 / 46 46 / 46 43 / 46 45 / 46 46 / 46 43 / 46 45 / 46 46 / 46 43 / 46 45 / 46 46 / 46
40
43
45
40
43
45
40
43
45
40
43
45
V1
Y1
1~
3~
50
220-240
380-415
25
16
18
→ Daikin Altherma high temperature
Solar collector
Dimensions
Weight
Volume
Surface
Coating
Absorber
Glazing
Allowed roof angle
Operating pressure
Stand still temperature
Thermal performance
EKSH26P
Unit
Unit
H xW xD
Outer
Aperture
Absorber
mm
kg
l
m²
m²
m²
Min.~Max.
Max.
Max.
Zero loss collector efficiency η0
°
bar
°C
%
EKSV21P
EKSV26P
1.300x2.000x85
2.000x1.006x85
2.000x1.300x85
42
35
42
2,1
1,3
1,7
2,6
2,01
2,6
2,350
1,79
2,35
2,360
1,8
2,36
Micro-therm (absorption max.96%, Emission ca. 5% +/-2%)
Harp-shaped copper pipe register with laser-welded highly selective coated aluminium plate
Single pane safety glass, transmission +/- 92%
15~80
6
200
-
Solar controller
EKSRPS3
Mounting
Dimensions
Unit
H xW xD
mm
Thermal performance Zero loss collector efficiency η0 %
Control
Type
Power consumption
W
Sensor
Solar panel temperature sensor
Storage tank sensor
Return flow sensor
Feed temperature and flow sensor
Power supply
Voltage
V
On side of tank
815x230x142
Digital temperature difference controller with plain text display
2
Pt1000
PTC
PTC
Voltage signal (3,5V DC)
230
Domestic hot water tank
EKHTS200AC
Casing
Colour
Metallic grey
Material
Dimensions
Unit
H xW xD
Weight
Unit
Empty
Tank
Water volume
Material
Maximum water temperature
Insulation
Heat loss
Heat exchanger Quantity
Tube material
Face area
Internal coil volume
Galvanised steel (precoated sheet metal)
2.010x600x695
2.285x600x695
70
78
200
260
Stainless steel (EN 1.4521)
75
1,2
1,5
1
Duplex steel (EN 1.4162)
1,56
7,5
mm
kg
l
°C
kWh/24h
m²
l
Domestic hot water tank
Dimensions
Weight
Tank
Unit
EKHTS260AC
Height
mm
Width
Depth
Empty
mm
mm
kg
l
°C
kWh/24h
Unit
Water volume
Maximum water temperature
Insulation
Heat loss
Heat exchanger Domestic hot Tube material
water
Face area
Internal coil volume
Operating pressure
Average specifc thermal output
Charging
Tube material
Face area
Internal coil volume
Operating pressure
Average specifc thermal output
Auxiliary solar Tube material
heating
Face area
Internal coil volume
Operating pressure
Average specifc thermal output
EKHWP300B
EKHWP500B
1.640
1.640
595
615
59
300
790
790
93
500
85
1,3
1,4
Stainless steel
m²
l
bar
W/K
5,8
27,9
6
29
6
2.790
2.900
Stainless steel
m²
l
bar
W/K
2,7
13,2
3,8
18,5
3
1.300
1.800
Stainless steel
m²
l
bar
W/K
-
0,5
2,3
3
-
19
280
→ Daikin Altherma high temperature
▪ Pricelist
Daikin Altherma cascade technology
High performance in 3 steps:
Daikin Altherma HT represents the most innovative solution for refurbishment
projects. Equipped with a double inverter cascade system, it can produce
leaving water temperatures up to 80°C, reached purely on thermodynamic
principles – without an additional direct electrical heater.
1
The outdoor unit extracts heat
from the ambient outdoor air. This
heat is transferred to the indoor unit
via R-410A refrigerant.
Change a boiler directly to Daikin Altherma HT - your radiators can stay, no
additional investments are necessary.
▪
Daikin Altherma high temperature outdoor units
Inverter Split Heat pump System with nominal capacities from 11 to 16 kW. Nominal capacity is measured at A7/W65, delta T 5K.
Can only be combined with an indoor unit of the same capacity class and power supply.
PRICE HUF
Daikin
Daikin
Daikin
Daikin
Daikin
Daikin
860.400,–
1.028.000,–
1.167.600,–
954.800,–
1.128.200,–
1.286.300,–
Altherma
Altherma
Altherma
Altherma
Altherma
Altherma
HT 11kW outdoor unit
HT 14kW outdoor unit
HT 16kW outdoor unit
HT 11kW outdoor unit
HT 14kW outdoor unit
HT 16kW outdoor unit
ERRQ011AV1
ERRQ014AV1
ERRQ016AV1
ERRQ011AY1
ERRQ014AY1
ERRQ016AY1
Power Supply 1~ 230V
Power Supply 1~ 230V
Power Supply 1~ 230V
Power Supply 3~400V
Power Supply 3~400V
Power Supply 3~400V
Daikin Altherma high temperature indoor units (floorstanding) for heating only applications.
All basic necessary hydraulic components included. Domestic Hot water tank can be mounted on top of or next to the indoor unit
as an option. Can only be combined with an outdoor unit of the same capacity class and power supply.
PRICE HUF
Daikin
Daikin
Daikin
Daikin
Daikin
Daikin
1.369.300,–
1.421.600,–
1.465.200,–
1.398.500,–
1.452.900,–
1.502.100,–
Altherma
Altherma
Altherma
Altherma
Altherma
Altherma
HT 11kW indoor unit
HT 14kW indoor unit
HT 16kW indoor unit
HT 11kW indoor unit
HT 14kW indoor unit
HT 16kW indoor unit
EKHBRD011ACV1
EKHBRD014ACV1
EKHBRD016ACV1
EKHBRD011ACY1
EKHBRD014ACY1
EKHBRD016ACY1
Floorstanding unit, power supply 1~ 230V
Floorstanding unit, power supply 1~ 230V
Floorstanding unit, power supply 1~ 230V
Floorstanding unit, power supply 3~ 400V
Floorstanding unit, power supply 3~ 400V
Floorstanding unit, power supply 3~ 400V
Combinations
INDOOR UNIT
230V
400V
OUTDOOR UNIT
EKHBRD011ACV1
ERRQ011AV1
ERRQ014AV1
ERRQ016AV1
ERRQ011AY1
ERRQ014AY1
ERRQ016AY1
●
–
–
–
–
–
EKHBRD014ACV1
EKHBRD016ACV1
EKHBRD011ACY1
230V
-
●
–
–
–
–
EKHBRD014ACY1
EKHBRD016ACY1
400V
–
–
●
–
–
–
20
–
–
–
●
–
–
–
–
–
–
●
–
–
–
–
–
–
●
→ Daikin Altherma high temperature
Outdoor
Step
Indoor
1
Step
2
Step
3
2
The indoor unit receives the heat
and further increases the temperature
with R-134a refrigerant.
3
The heat is transferred from the R-134a
refrigerant circuit to the water circuit.
Thanks to the unique cascade compressor
approach, water temperatures of 80°
C can be reached without using an
additional back-up heater.
Applicable for:
11-16kW
Options & accessories
Wired room thermostat
Wireless room thermostat
Digital I/O PCB
Modbus PCD
Sequencing Controller
EKRTWA
EKRTR
EKRP1HBA
RTD-W
EKCC-W
Thermostat external sensor
EKRTETS
Demand PCB for connection of room
thermostat or backup heater
Remote user interface
EKRP1AHT
In-line backup heater 1~, 230V, 6kW
In-line backup heater 3~, 400V, 6kW
Option kit for standalone tank
Domestic hot water connection kit for
EKHWP300B
Domestic hot water connection kit for
EKHWP500B
EKBUHA6V3
EKBUHA6W1
EKFMAHTB
EKEPHT3H
Wired Digital Room Thermostat
Wireless Digital Room Thermostat
Remote alarm / operation status / …
Monitoring and control ModBus interface
Master/slave control kit that can control and monitor up
to 16 hydroboxes, connected through RTD-W
Temperature measurement remotely from wireless
room thermostat (e.g. floor temperature)
Required when EKRTWA or EKRTR is used as a room
thermostat or if a backup heater is installed
Can be used as a second user interface (master/slave)
besides the one delivered with the indoor unit
Electrical backup heater for space heating support only
Electrical backup heater for space heating support only
Kit required when EKHTS tanks are to be placed next to the indoor unit
Connection kit for HT in combination with EKHWP300B
EKEPHT5H
Connection kit for HT in combination with EKHWP500B
EKRUAHTB
Domestic hot water tanks
Stainless steel domestic hot water tank
200L
Stainless steel domestic hot water tank
260L
Pressureless 300L domestic hot water tank
Pressureless 500L domestic hot water tank
EKHTS200AC
EKHTS260AC
EKHWP300B
EKHWP500B
Domestic hot water tank 200L, Dimensions HxBxT = 1.335x600x695,
height increases to 2.010 mm if mounted on top of indoor unit
Domestic hot water tank 260L, Dimensions HxBxT = 1.610x600x695,
height increases to 2.285 mm if mounted on top of indoor unit
Pressureless hygienic domestic hot water tank with solar option
Pressureless hygienic domestic hot water tank with solar option
21
●
●
●
●
●
PRICE HUF
38.000,–
71.700,–
41.100,–
111.400,–
305.100,–
●
4.700,–
●
41.100,–
●
●
●
●
●
181.600,–
181.600,–
164.600,–
●
140.100,–
Applicable for:
11-16kW
PRICE HUF
●
448.300,–
●
●
●
61.700,–
78.000,–
506.500,–
546.000,–
664.200,–
→ Daikin Altherma Flex Type
Efficient climate control for
residential applications
Outdoor
1
2
3
Hot water
Heating
Cooling
One or more outdoor units
+ several indoor units
>> a modular system
2
Outdoor unit
3
Heating/Cooling
=
1
Indoor installation
+
Indoor unit
Domestic hot
water tank
Commercial applications
Fit for purpose &
Hot water on demand
The challenges for a fitness center:
•
•
Large exercise rooms with high levels
of heat being generated requiring
rigorous climate control throughout
the space
High ‘on demand’ hot water usage
in the changing rooms
The solution:
•
Daikin Altherma Flex
Type with its modular
and flexible
approach.
32
→ Daikin Altherma Flex Type
3-IN-1 SYSTEM
Daikin Altherma Flex Type heats, cools and produces domestic hot water:
• Heating: leaving water temperatures up to 80° C
• Cooling: leaving water temperatures down to 5° C
• Hot water: tank temperatures up to 75° C
Thanks to the heat recovery function, the system can heat up the hot water tank up to 60°C with rejected heat from
cooling operation.
ENERGY EFFICIENT HEAT PUMP TECHNOLOGY
Compared to an oil boiler, this results in:
• Up to 36% less running costs*
• Up to 71% reduction of CO2 emissions*
• Up to 35% reduction in primary energy use*
* Data calculated taking in account Belgian conditions: SCOP of 3, average energy prices 2007-2010, CO2 emission factor for electricity production
MODULAR SYSTEM
One or more inverter-controlled outdoor heat pump units can provide heating, cooling and hot water. Outdoor units
between 23 and 45 kW extract the heat from the outdoor air, raise it to an intermediate temperature and transfer this heat
energy to the individual indoor units.
Indoor units are available in several classes (6, 9, 11 ,14 and 16 kW ), ensuring optimum efficiency. One outdoor unit can be
combined with up to ten indoor units. Multiple outdoor units can be installed for larger applications.
1 Commercial space /
1 Apartment
6kW
5kW
9kW
11kW
14kW
Total building
16kW
22kW
45kW
20kW
8kW
40kW
Install separate
outdoor units to reach higher
capacities
(Separate system:
the outdoor units are not
connected to each other)
Note:
Heating capacities 7°C ambient
temperature, cooling capacities
35°C ambient temperature
1P, 230V
33
3P, 400V
→ Daikin Altherma Flex Type
▪ Technical specifications
OUTDOOR UNIT
Heating capacity
Cooling capacity
Dimensions
Weight
Operation
range
Refrigerant
Piping
connections
Nom.
Nom.
Unit
Unit
Heating
Domestic hot water
Cooling
Type
Liquid
Suction
High and low pressure gas
Piping length
kW
kW
HxWxD
mm
kg
Min.~Max.
°CWB
Ambient Min.~Max. °CDB
Min.~Max.
°CDB
OD
OD
OD
OU - IU Max.
System Equivalent
Total piping length System Actual
Sound power level Heating
Nom.
Sound pressure level Heating
Nom.
Power supply
Phase/Voltage
mm
mm
mm
m
m
m
dBA
dBA
V
EMRQ8A
EMRQ10A
EMRQ12A
EMRQ14A
EMRQ16A
22,4
20
28
25
33,6
30
1.680x1.300x765
39,2
35
44,8
40
331
339
-15~20
-15~35
10~43
R-410A
9,52
19,1
15,9
19,1
78
58
Heating conditions: Ta = 7°CDB / 6°CWB, 100% connection ratio
Cooling conditions: Ta = 35°CDB, 100% connection ratio
* Capacity not guaranteed between -20°C and -15°C
34
12,7
28,6
22,2
22,2
100
120
300
80
60
3~/380-415
83
62
84
63
→ Daikin Altherma Flex Type
INDOOR UNIT
Casing
Dimensions
Weight
Operation
range
EKHVMRD50A
Material
Unit
Unit
Heating
HxWxD
EKHVMYD80A
Min.~Max.
Min.~Max.
Min.~Max.
Min.~Max.
Min.~Max.
Min.~Max.
Precoated sheet metal
705x600x695
mm
kg
°C
°C
°CDB
°C
°CDB
°C
kg
dBA
dBA
92
120
-15~20
25~80
-~-~-
10~43
5~20
-15~35
45~75
R-134a
2
40 1 / 43 2
42 1 / 43 2
40 1 / 43 2
42 1 / 43 2
38 1
V1
1~
50
220-240
20
Hz
V
A
INDOOR UNIT
Dimensions
Weight
Operation
range
EKHVMYD50A
Metallic grey
Ambient
Water side
Cooling
Ambient
Water side
Domestic hot Ambient
water
Water side
Refrigerant
Type
Charge
Sound pressure Nom.
level
Night quiet mode Level 1
Power supply
Name
Phase
Frequency
Voltage
Current
Recommended fuses
Casing
EKHVMRD80A
Colour
EKHBRD011ACV1 EKHBRD014ACV1 EKHBRD016ACV1 EKHBRD011ACY1 EKHBRD014ACY1 EKHBRD016ACY1
Colour
Material
Unit
Unit
Heating
Metallic grey
HxWxD
Ambient
Water side
Cooling
Ambient
Water side
Domestic hot Ambient
water
Water side
Refrigerant
Type
Charge
Sound pressure Nom.
level
Night quiet mode Level 1
Power supply
Name
Phase
Frequency
Voltage
Current
Recommended fuses
Min.~Max.
Min.~Max.
Min.~Max.
Min.~Max.
Min.~Max.
Min.~Max.
Precoated sheet metal
705x600x695
mm
kg
°C
°C
°CDB
°C
°CDB
°C
kg
dBA
dBA
144,25
147,25
-20~20
25~80
-~-~-20~35
25~80
R-134a
3,2
43 1 / 46 2
40 1
Hz
V
A
45 1 / 46 2
43 1
V1
1~
46 1 / 46 2
45 1
43 1 / 46 2
40 1
45 1 / 46 2
43 1
Y1
3~
50
220-240
25
(1) Sound levels are measured at: EW 55°C; LW 65°C (2) Sound levels are measured at: EW 70°C; LW 80°C
35
380-415
16
46 1 / 46 2
45 1
→ Daikin Altherma Flex Type
▪ Pricelist
Daikin Altherma Flex Type for residential and commercial applications is a
3-in-1 system offering heating, domestic hot water and cooling all-in-one
highly efficient.
Daikin Altherma Flex Type achieves a typical seasonal COP of 3 in the
moderate Western and central European climate. Further more, Daikin
Altherma Flex Type is a modular system. Depending from your project one
or more outdoor units can be combined with up to ten indoor units per
outdoor unit.
Daikin Altherma Flex Type outdoor units.
Nominal heating capacity is measured at Ta 7°C and nominal cooling capacity at Ta 35°C with a 100% connection ratio.
PRICE HUF
Daikin Altherma Flex outdoor unit 8HP
EMRQ8A
2.332.900,–
Daikin Altherma Flex outdoor unit 10HP
EMRQ10A
Daikin Altherma Flex outdoor unit 12HP
EMRQ12A
Daikin Altherma Flex outdoor unit 14HP
EMRQ14A
Daikin Altherma Flex outdoor unit 16HP
EMRQ16A
Outdoor unit with 22,4kW heating and 20kW
cooling capacity, power suppy 3~ 400V
Outdoor unit with 28 kW heating and 25kW cooling
capacity, power suppy 3~ 400V
Outdoor unit with 33,6kW heating and 30kW
cooling capacity, power suppy 3~ 400V
Outdoor unit with 39,2kW heating and 35kW
cooling capacity, power suppy 3~ 400V
Outdoor unit with 44,8kW heating and 40kW
cooling capacity, power suppy 3~ 400V
Daikin Altherma Flex Type indoor units (floorstanding) for heating& cooling and heating only applications.
All basic necessary hydraulic components included.
Daikin Altherma Flex 5kW indoor unit
heating only
Daikin Altherma Flex 5kW indoor unit
heating & cooling
Daikin Altherma Flex 8kW indoor unit
heating
Daikin Altherma Flex 8kW indoor unit
heating & cooling
Daikin Altherma Flex 11kW indoor unit
heating only
Daikin Altherma Flex 14kW indoor unit
heating only
Daikin Altherma Flex 16kW indoor unit
heating only
Daikin Altherma Flex 11kW indoor unit
heating only
Daikin Altherma Flex 14kW indoor unit
heating only
Daikin Altherma Flex 16kW indoor unit
heating only
2.472.800,–
2.706.100,–
3.266.000,–
3.732.600,–
PRICE HUF
EKHVMRD50A
Power Supply 1~ 230V
1.259.500,–
EKHVMYD50A
Power Supply 1~ 230V
1.396.400,–
EKHVMRD80A
Power Supply 1~ 230V
1.300.400,–
EKHVMYD80A
Power Supply 1~ 230V
1.437.900,–
EKHBRD011ACV1
Power Supply 1~ 230V
1.369.300,–
EKHBRD014ACV1
Power Supply 1~ 230V
1.421.600,–
EKHBRD016ACV1
Power Supply 1~ 230V
1.465.200,–
EKHBRD011ACY1
Power Supply 3~400V
1.398.500,–
EKHBRD014ACY1
Power Supply 3~400V
1.452.900,–
EKHBRD016ACY1
Power Supply 3~400V
1.502.100,–
36
→ Daikin Altherma Flex Type
Applicable for:
11-16kW
Options & accessories
Wired room thermostat
Wireless room thermostat
Digital I/O PCB
Modbus Interface
Sequencing Controller
EKRTWA
EKRTR
EKRP1HBA
RTD-W
EKCC-W
Thermostat external sensor
EKRTETS
Demand PCB for connection of room
thermostat or backup heater
Remote user interface
EKRP1AHT
In-line backup heater 1~, 230V, 6kW
In-line backup heater 3~, 400V, 6kW
Option kit for standalone tank
Optionional billing kit
Central drainpan kit for outdoor unit
Domestic hot water connection kit for
EKHWP300B
Domestic hot water connection kit for
EKHWP500B
EKBUHA6V3
EKBUHA6W1
EKFMAHTB
EKMBIL1
KWC25C450
EKEPHT3H
Wired Digital Room Thermostat
Wireless Digital Room Thermostat
Remote alarm / operation status
monitoring and control ModBus interface
master/slave control kit that can control and monitor up
to 16 hydroboxes, connected through RTD-W
Temperature measurement remotely from wireless
room thermostat (e.g. floor temperature)
required when EKRTWA or EKRTR is used as a room
thermostat or if a backup heater is installed
can be used as a second user interface (master/slave)
besides the one delivered with the indoor unit
Electrical backup heater for space heating support only
Electrical backup heater for space heating support only
Kit required when EKHTS tanks are to be placed next to the indoor unit
Option kit for billing of tank mounted on indoor unit
drain pan kit to collect the condensate after defrost operation
connection kit for HT in combination with EKHWP300B
EKEPHT5H
connection kit for HT in combination with EKHWP500B
EKRUAHTB
Domestic hot water tanks
Stainless steel domestic hot water tank
200L
Stainless steel domestic hot water tank
260L
Pressureless 300L domestic hot water tank
Pressureless 500L domestic hot water tank
EKHTS200AC
EKHTS260AC
EKHWP300B
EKHWP500B
Domestic hot water tank 200L, Dimensions HxBxT = 1335x600x695,
height increases to 2010 if mounted on top of indoor unit
Domestic hot water tank 200L, Dimensions HxBxT = 1610x600x695,
height increases to 2285 if mounted on top of indoor unit
pressureless hygienic domestic hot water tank with solar option
pressureless hygienic domestic hot water tank with solar option
Refrigerant branch kits for outdoor units
Outdoor unit capacity type (HP)
8 + 10
Price
12 ~ 16
Price
3 pipes
HUF
HUF
imperial
KHRQ23M29T9
52.100,–
KHRQ23M64T
82.900,–
Refnet joints for indoor units
Indoor unit capacity index
< 200
Price
200 ≤ x < 290
Price
290 ≤ x < 520
Price
HUF
HUF
Refnet headers for indoor units
Indoor unit capacity index
<200 and 200 ≤ x < 290
Price
290 ≤ x < 520
Price
HUF
HUF
4.700,–
●
41.100,–
●
●
●
●
●
●
●
181.600,–
181.600,–
164.600,–
42.800,–
341.700,–
●
140.100,–
Applicable for:
11-16kW
PRICE HUF
●
448.300,–
●
●
●
61.700,–
78.000,–
506.500,–
546.000,–
664.200,–
metric
KHRQM22M29T
46.300,–
KHRQM22M64T
55.600,–
3 pipes
metric
KHRQM23M20T
44.400,–
KHRQM23M29T
52.100,–
KHRQM23M64T
82.900,–
imperial
KHRQ22M20T
34.100,–
KHRQ22M29T9
46.300,–
KHRQ22M64T
55.600,–
metric
KHRQM23M29H
90.700,–
KHRQM23M64H
110.600,–
imperial
KHRQ22M29H
64.600,–
KHRQ22M64H
80.100,–
3 pipes
imperial
KHRQ23M29H
90.700,–
KHRQ23M64H
110.600,–
305.100,–
●
imperial
KHRQ22M29T9
46.300,–
KHRQ22M64T
55.600,–
3 pipes
HUF
38.000,–
71.700,–
41.100,–
111.400,–
3 pipes
metric
KHRQM23M29T
52.100,–
KHRQM23M64T
82.900,–
imperial
KHRQ23M20T
44.400,–
KHRQ23M29T9
52.100,–
KHRQ23M64T
82.900,–
●
●
●
●
●
PRICE HUF
metric
KHRQM22M20T
34.100,–
KHRQM22M29T
46.300,–
KHRQM22M64T
55.600,–
3 pipes
37
metric
KHRQM22M29H
64.600,–
KHRQM22M64H
80.100,–
→ Heat pump convector
Heat pump convector
The heat pump convector unit
can provide both
heating and cooling
if required, since the heat
pump convector is more than just a fan coil unit.
The heat pump convector also has a very low noise
level.
38
When combining under floor heating and fan coil units, the
low leaving water temperatures, important for efficiency,
are adequate for under floor heating, but the fan coil units
then need to be oversized in order to emit the proper levels
of heat at these low water temperatures. The heat pump
convector solves this problem.
The heat pump convector is able to emit the required
levels of heat at low leaving water temperatures, while
retaining a modest size.
Instead of the leaving water circuit being switched on
and off via a thermostat in a single master room, each
heat pump convector can be directly wired to the Daikin
Altherma indoor unit, the system’s intelligence centre. This
allows all rooms to have heat when required, regardless of
the state of the other rooms.
The heat pump convector saves on running
costs thanks to the improved efficiency by approximately
25% compared to a heating system that combines underfloor heating and regular fan coil units. The heat pump
convector can easily replace existing heat emitters, thanks
to its plug and play installation.
→ Heat pump convector
→ Heat pump convector
▪ Technical specifications
INDOOR UNITS
Heating capacity
Cooling capacity
Total capacity Nom.
Total capacity Nom.
Sensible
Nom.
capacity
Power input
Heating
Nom.
Cooling
Nom.
Dimensions
Unit
H xW xD
Weight
Unit
Piping connections Drain/OD/Inlet/Outlet
Sound pressure
level
Power supply
Heating
Nom.
Cooling
Nom.
Phase/Frequency/Voltage
kW
kW
kW
kW
kW
mm
kg
mm/
inch
dBA
dBA
Hz/V
FWXV20A
FWXV15A
2,0
1,7
1,4
1,5
1,2
0,98
0,015
0,015
0,013
0,013
600/700/210
15
18/G 1/2/G 1/2
29
29
19
19
1~/50/60/220-240/220
(1) Cooling: indoor temp. 27°CDB, 19°CWB; entering water temp. 7°C, water temperature rise 5K.
(2) Heating: room temperature 20°CDB and entering water temperature 45°C, water temperature drop 5K.
▪ Pricelist
Daikin‘s Heat pump convector with interlink function is another heating
innovation coming from the Daikin internal product development. Perfectly
suitable for low temperature applications, e.g. in combination with underfloor
heating, the Heat pump convector is a stylish, compact, intelligent and very
silent solution for quick heating or cooling of residential areas.
Daikin Altherma Heat pump Convector
Daikin Altherma
Heat pump Convector 1,5kW
Daikin Altherma
Heat pump Convector 2,0kW
FWXV15A
FWXV20A
PRICE HUF
Heat pump convector with 1,5kW* heating capacity
and 1,2kW** and 0,3kW*** cooling capacity
Heat pump convector with 2,0kW* heating capacity
and 1,7kW** and 0,4kW*** cooling capacity
Options & Accessories
2 way valve kit
190.400,–
206.500,–
PRICE HUF
EKVKHPC
needs to be used in all cooling and high temperature applications, where
watertemperatures of below 18°C and/or 60°C or above can occur
* water inlet temperature 45°C and water outlet temperature 40°C, room temperature 20°C DB - medium fanspeed
**water inlet temperature 7°C and water outlet temperature 12°C, room temperature 27°C DB / 19°C WB - medium fanspeed
***water inlet temperature 18°C and water outlet temperature 23°C, room temperature 27°C DB / 19°C WB - medium fanspeed
39
26.000,–
→ Daikin solar system
Solar connection
Daikin offers two types of solar
systems in combination with
their heat pumps.
1
Pressureless system
The system is filled with pure water which is transferred
from the pressureless energy storage tank, whenever the
sun is out. If no sun is out and thus no energy is needed, the
water is drained back into the pressureless energy storage
tank.
2
3
Pressurised system
The system is filled with heat transfer fluid with the correct
amount of of antifreeze to avoid freezing in winter. The
whole system is then pressurised and sealed.
Solar kit
1- Solar collector
The solar kit provides the transfer of solar heat to the Daikin
Altherma hot water tank via an external heat exchanger.
In contrast to tanks with two heat exchangers, this system
allows the entire content of the tank to be efficiently heated
with solar heat and, if necessary, with heat pump energy.
2- Solar pump station
Solar collector
The high-efficiency collectors transfer all the short-wave
solar radiation into heat as a result of their highly selective
coating. The collectors can be mounted on the roof tiles.
What do you need?
•
•
•
•
•
Solar collector
Plumbing network and solar pump station
Supply tank: standard Daikin Altherma domestic hot
water tank
Solar kit
Re-heater (Daikin Altherma heat pump unit which also
provides the home with heating)
40
3- Solar kit available in combination with stand alone
(EKHWS - EKHWE) domestic hot water tank
→ Daikin solar system
Solar collector
Solar collectors
Averaged over an entire year, the sun
delivers half of the energy we need to bring
our domestic hot water up to the desired
temperature. High-efficiency collectors
with highly selective coating transfer all the
short-wave solar radiation into heat. The
collectors can be mounted on roof tiles.
Operation
The solar collectors are only filled with
water when sufficient heat is provided by
the sun. In this case, both pumps in the
control and pump unit switch on briefly
and fill the collectors with storage tank
water. After filling, which takes less than
a minute, one of the pumps switches off
and water circulation is maintained by the
remaining pump.
Indoor unit and
domestic hot water tank
EKHWP: domestic hot water tank
The domestic hot water tank has two sections: The upper, always hot, section – the
lower, colder section – the solar zone.
1.
2.
active water zone – and the
The active water
is heated in the upper section of the storage tank. The high temperature of this zone
ensures that sufficient hot water is always available.
Solar collectors work more efficiently when colder water flows through the solar collectors. Therefore, the water
that is fed directly to the solar collectors in solar operation is stored in the solar zone.
13
2 3
1 4 14
12
6
5
7
10
1. Cold water connection
12. Fill level indicator
2. Hot water connection
13. Connection for booster heater
10
3. Storage tank charging flow
14. Electric immersion booster heater
8
4. Storage tank charging return flow
15. Sensor pocket for tank temperature
sensor
18
5. Heating support flow
21
6. Heating support return
7. Drain Back solar flow
16
9
8. Storage tank (polypropylene double
walled jacket with PUR hard foam heat
insulation)
9
24
17
9. Mount for solar R3 controller / handle
10. Safety overflow connection
11
20
11. Drain-back solar - return flow / Filling
and draining connection for storage
tank water
23
19
15
41
16. Domestic hot water heat exchanger
17. Charging heat exchanger
18. Inlet from solar collector
19. Pressure-free storage tank water
20. Solar zone
21. Hot water zone
→ Daikin solar system
▪ Technical specifications
SOLAR CONNECTION
EKSOLHWAV1
Dimensions
Unit
H xW xD
Weight
Unit
Operation
Ambient
Min,~Max,
range
temperature
Sound pressure Nom,
level
Zero loss collector efficiency η0
Thermal
performance
Power supply
Phase/Frequency/Voltage
Power supply intake
mm
kg
°C
770x305x270
8
1~35
dBA
27
%
-
Hz/V
1~/50/220-240
Indoor unit
ACCESSORY
Mounting
Dimensions
Thermal
performance
Control
Sensor
Power supply
EKSR3PA
Unit
H xW xD
Zero loss collector efficiency η0
On wall
332x230x145
mm
%
-
Type
Power consumption
W
Solar panel temperature sensor
Storage tank sensor
Return flow sensor
Feed temperature and flow sensor
Frequency/Voltage
Hz/V
Digital temperature difference controller with plain text display
2
Pt1000
PTC
PTC
Voltage signal (3,5V DC)
50/230
SOLAR COLLECTOR
Dimensions
Weight
Volume
Surface
Coating
Absorber
Glazing
Allowed roof
angle
Operating
pressure
Stand still
temperature
Thermal
performance
Unit
Unit
H xW xD
Outer
Aperture
Absorber
mm
kg
l
m²
m²
m²
Min,~Max,
°C
Max,
bar
Max,
°C
Zero loss collector efficiency η0
Heat loss coefficient a1
Temperature dependence of
the heat loss coefficient a2
Thermal capacity
Incident
AM at 50°
angle
modifier
%
W/m²,K
W/
m²,K²
kJ/K
6
200
Vertical
Unit
H xW xD
Type
Power consumption
EKSV21P
15~80
SOLAR CONNECTION
Mounting
Sensor
EKSH26P
1,300x2,000x85
2,000x1,006x85
42
35
1,7
2,1
1,3
2,601
2,01
2,364
1,795
2,354
1,791
Micro-therm (absorption max,96%, Emission ca, 5% +/-2%)
Harp-shaped copper pipe register with laser-welded highly selective coated aluminium plate
Single pane safety glass, transmission +/- 92%
Installed position
Dimensions
Control
EKSV26P
2,000x1,300x85
78,7
4,270
78,3
4,25
0,0070
0,0057
6,5
-
0,94
Horizontal
Vertical
EKSRPS3B
mm
Digital temperature difference controller with plain text display
On side of tank
Pt1000
PTC
PTC
Voltage signal (3,5V DC)
W
Solar panel temperature sensor
Storage tank sensor
Return flow sensor
Feed temperature and flow sensor
42
→ Daikin solar system
▪ Pricelist
For Daikin Altherma LT, HT and Flex units a pressurised and pressureless solar system is available. Main components are
the standard Daikin tanks as well as pressureless hygienic domestic hot water tanks, combined with Daikin‘s solar kits and
controllers and solar panels for on-roof, in-roof and flat roof installations.
Material
Solar Panel
Daikin hot water tanks & accessories
Solar Controlers & Pump Stations
Solar priority PCB + cable
Solar panel installation accessories
Description
Price per unit HUF
EKSV26P
Vertical big solar panel 2000 x 1300 mm
EKSH26P
Horizontal big solar panel 2000 x 1300 mm
EKSV21P
Vertical small solar panel 2000 x 1006 mm
EKHWS*
EKHWE*
EKSOLHW
EKHWP300B
EKHWP500B
165070
164102-RTX
156015
156016
162070
162050
162051-RTX
EKSRPS3B
EKSR3PA
EKSRDS1A
164116
EKRP1HBA
164110-RTX
164732
164733
164261-RTX
164262-RTX
164263
164264
162073
162071
162074
162072
162075
162076
EKSRCRP
EKSRCAP
EKSRCP
162037-RTX
162038-RTX
164709
162016-RTX
162035-RTX
162045
162066
162067
162068
164245
162036-RTX
162069
164723
164703-RTX
164704-RTX
162017
162018
162019
162020
164616-RTX
162058
162059
162060
162061
162029-RTX
162052-RTX
Stainless steel tank
Enameled tank
Solar heat exchanger kit
Hygienic Domestic hot water tank, 300l
Hygienic Domestic hot water tank, 500l
Set of 2 gravity brakes
FLG - flow regulating valve with flow rate indicator
Thermostatic antiscald mixing valve
1“ screw connection set for VTA32
Solar Expansion Vessel 12L
Solar Expansion Vessel 25L
Solar Expansion Vessel 35L
Solar controller for drain back applications
Solar controller for pressurized applications
Solar pump station
Flow sensor for a pressurized system
PCB kit to disable hot water mode through HP during solar water heating
Solar priority cable / connection cable to disable heatpump
Pressureless Connection piping between solar panel & pump station: 15m
Pressureless Connection piping between solar panel & pump station: 20m
Pressureless elongation pipe 2,5m including couplings
Pressureless elongation pipe 5m including couplings
Pressureless elongation pipe 10m including couplings
Pressureless elongation for inlet pipe 8m
Pressure solar pipe DN16 - 15m
Connectors DN16
Pressure solar pipe DN20 - 15m
Connectors DN20
Pressure solar connection set DN 16
Pressure solar connection set DN 20
Connection kit, incl. red roof tile
Connection kit, incl. anthracite roof tile
Connection kit ON ROOF
Mounting kit IN-ROOF
Mounting kit FLAT ROOF
Additional roof breakthrough for opposite side connection
Connection kit between 2 solar panels
Connection kit between 2 rows of collectors
Connection kit between 2 rows of collectors
Mounting rail for V21
Mounting rail for V26P
Mounting rail for H26P
Suporting shell for pressureless connection pipe
Variable height mounting set for on-roof mounting suitable for roof tiles
Standard mounting set for on-roof mounting suitable for roof tiles
Mounting set for on-roof mounting suitable for flat tiles e.g. shingles
Mounting set for on-roof mounting suitable for corrugated plates
Mounting set for on-roof mounting suitable for metal roofs
Basic IN ROOF installation kit for 2 EKSV21P
Extension IN ROOF installation kit for 1 additional EKSV21P
Basic IN ROOF installation kit for 2 EKSV26P
Extension IN ROOF installation kit for 1 additional EKSV26P
IN ROOF covering slate complementing kit
Basic FLAT ROOF support frame for 2 EKSV26P
Extension FLAT ROOF support frame for additional EKSV26P
Basic FLAT ROOF support frame for 1 EKSH26P
Extension FLAT ROOF support frame for additional EKSH26P
Release tool
20l ready to use glycol Tmin = -28°C
FLG
VTA32
MAGS12
MAGS25
MAGS35
BSKK
CON15
CON20
CONX25
CONX50
CONX100
CONXV80
CON15P16
CONXP16
CON15P20
CONXP20
CONCP16
CONCP20
RCIP
RCFP
CONFE
FIXVBP
CONRVP
CONLCP
FIXMP100
FIXMP130
FIXMP200
TS
FIXADP
FIXADD
FIXADS
FIXWD
FIXBD
IBV21P
IEV21P
IBV26P
IEV26P
FIXIES
FBV26P
FEV26P
FBH26P
FEH26P
FIXLP
GFL
43
209.800,–
215.800,–
182.900,–
see page 9
see page 9
230.500,–
546.000,–
664.200,–
3.500,–
17.700,–
22.500,–
8.900,–
42.100,–
41.400,–
63.800,–
228.200,–
101.600,–
151.100,–
50.800,–
41.100,–
5.300,–
40.800,–
48.500,–
25.400,–
29.000,–
37.800,–
32.500,–
146.600,–
3.500,–
181.400,–
5.300,–
22.500,–
32.300,–
81.300,–
81.300,–
58.800,–
40.200,–
76.800,–
23.600,–
16.500,–
21.300,–
32.500,–
11.800,–
13.000,–
17.700,–
2.400,–
29.000,–
7.200,–
17.100,–
16.500,–
19.500,–
146.600,–
65.600,–
156.600,–
68.600,–
38.400,–
176.100,–
70.300,–
83.300,–
54.400,–
2.400,–
27.800,–
→ Daikin solar system
▪
Drain back combination tables
EKSV21P Drain back
# of panels
Material
EKSV21P
FIXVBP
FIXMP100
FIXADP
FIXADS
FIXWD
FIXDB
IBV21P
IEV21P
EKHWP***B
EKSRPS3B
EKRP1HBA
BSKK
FLG
TS
CON15
EKSRCAP/EKSRCRP
RCIP
EKSH26P Drain back
2
3
4
5
On
roof
2
1
2
In
roof
2
1
2
On
roof
3
2
3
In
roof
3
2
3
On
roof
4
3
4
In
roof
4
3
4
On
roof
5
4
5
In
roof
5
4
5
2
0
3
0
4
0
5
0
0
0
1
1
1
1
1*
1
1
1
0
1
0
1
1
1
1
1*
1
1
0
1
0
0
1
1
1
1
1*
1
1
1
0
1
1
1
1
1
1
1*
1
1
0
1
0
0
1
1
1
1
1*
1
1
1
0
1
2
1
1
1
1
1*
1
1
0
1
0
0
1
1
1
1
1*
1
1
1
0
1
3
1
1
1
1
1*
1
1
0
1
# of panels
Material
EKSH21P
FIXVBP
FIXMP200
FIXADP
FIXADS
FIXWD
FIXDB
FBH26P
FEH26P
EKHWP***B
EKSRPS3B
EKRP1HBA
BSKK
FLG
TS
CON15
EKSRCAP/EKSRCRP
RCFP
* : optional (recommended)
1
2
On Flat On
roof roof roof
1
1
2
0
0
1
1
1
2
3
4
5
Flat On Flat On Flat On
roof roof roof roof roof roof
2
3
3
4
4
5
1
2
2
3
3
4
2
3
3
4
4
5
Flat
roof
5
4
5
1
0
2
0
3
0
4
0
5
0
0
0
1
1
1
1
1*
1
1
1
0
1
0
1
1
1
1
1*
1
1
0
1
0
0
1
1
1
1
1*
1
1
1
0
1
1
1
1
1
1
1*
1
1
0
1
0
0
1
1
1
1
1*
1
1
1
0
1
2
1
1
1
1
1*
1
1
0
1
0
0
1
1
1
1
1*
1
1
1
0
1
3
1
1
1
1
1*
1
1
0
1
0
0
1
1
1
1
1*
1
1
1
0
1
4
1
1
1
1
1*
1
1
0
1
* : optional (recommended)
EKSV26P Drain back
# of panels
Material
EKSV26P
FIXVBP
FIXMP130
FIXADP
FIXADS
FIXWD
FIXDB
IBV26P
IEV26P
FBV26P
FEV26P
EKHWP***B
EKSRPS3B
EKRP1HBA
BSKK
FLG
TS
CON15
EKSRCAP/EKSRCRP
RCIP
RCFP
2
3
4
5
On
In Flat On
In Flat On
In Flat On
In Flat
roof roof roof roof roof roof roof roof roof roof roof Roof
2
2
2
3
3
3
4
4
4
5
5
5
1
1
1
2
2
2
3
3
3
4
4
4
2
2
2
3
3
3
4
4
4
5
5
5
2
0
0
3
0
0
4
0
0
5
0
0
0
0
0
0
1
1
1
1
1*
1
1
1
0
0
1
0
0
0
1
1
1
1
1*
1
1
0
1
0
0
0
1
0
1
1
1
1
1*
1
1
0
0
1
0
0
0
0
1
1
1
1
1*
1
1
1
0
0
1
1
0
0
1
1
1
1
1*
1
1
0
1
0
0
0
1
1
1
1
1
1
1*
1
1
0
0
1
0
0
0
0
1
1
1
1
1*
1
1
1
0
0
1
2
0
0
1
1
1
1
1*
1
1
0
1
0
0
0
1
2
1
1
1
1
1*
1
1
0
0
1
0
0
0
0
1
1
1
1
1*
1
1
1
0
0
1
3
0
0
1
1
1
1
1*
1
1
0
1
0
0
0
1
3
1
1
1
1
1*
1
1
0
0
1
* : optional (recommended)
▪
Additional items drain back in function of installation
Material
Description
Required quantity
165070
CONX25
CONX100
CONX50
CONXV80
CONRVP
Gravity brakes
1 set per tank heat exchanger adviced if piping from heat exchanger is not making downward bend at the tank
Elongation sets
Depending on required elongation
Elongation pipe with couplings for inlet 8 m
Connection pipe between solar panel rows
Only required if rooftransit of outlet pipe collector can not be located next to outlet connection of solar collector
Number of rows - 1; Remove 1 FIXVBP per CONRVP
44
→ Daikin solar system
▪
Pressurised combination tables
EKSV21P Pressurised
# of panels
Material
EKSV21P
FIXVBP
FIXMP100
FIXADD
FIXADP
FIXWD
FIXDB
IBV21P
IEV21P
EKHWS / EKHWE
EKSOLHWAV1
EKSRDS1A
164116
EKSR3PA
FLG
CON15P16
CONCP16
CON15P20
CONCP20
MAGS12
MAGS25
MAGS35
EKSRCP
GFL
EKSV26P Pressurised
2
3
4
On
roof
2
1
2
6
In
roof
2
1
2
0
On
roof
3
2
3
10
In
roof
3
2
3
0
On
roof
4
3
4
12
2
0
3
0
4
0
0
1
1
1
1
1
1*
1
1
0
0
1
0
0
1
# of panels
Material
In
roof
4
3
4
0
standard roof tiles
0
1
0
1
0
0
0
1
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1*
1*
1*
1*
1
1
1
0
1
1
1
0
0
0
0
1
0
0
0
1
1
0
0
0
0
1
1
0
0
0
0
1
1
1
1
1
Depending on system volume
1
2
3
On In Flat On In Flat On In Flat
roof roof roof roof roof roof roof roof roof
1
2
2
2
3
3
3
0
1
1
1
2
2
2
1
2
2
2
3
3
3
4
6
10
standard roof tiles
EKSV26P
FIXVBP
FIXMP130
FIXADD
FIXADP
FIXWD
1
FIXDB
IBV26P
0
IEV26P
0
FBV26P
0
FEV26P
0
EKHWS / EKHWE 1
EKSOLHWAV1
1
EKSRDS1A
1
164116
1
EKSR3PA
1
FLG
1*
CON15P16
1
CONCP16
1
MAGS12
1
MAGS25
0
EKSRCP
1
GFL
other roof types
1
2
1
1
1
1
1
1*
0
0
1
1
0
0
1
1
* : optional (recommended)
* : optional (recommended)
EKSH26P Pressurised
# of panels
Material
EKSH21P
FIXVBP
FIXMP200
FIXADD
FIXADP
FIXWD
FIXDB
FBH26P
FEH26P
EKHWS / EKHWE
EKSOLHWAV1
EKSRDS1A
164116
EKSR3PA
FLG
CON15P16
CONCP16
MAGS25
EKSRCP
GFL
1
2
3
On
roof
Flat
roof
On
roof
Flat
roof
On
roof
Flat
roof
1
0
1
4
1
0
1
0
2
1
2
6
2
1
2
0
3
2
3
10
3
2
3
0
standard roof tiles
1
0
2
0
3
0
other roof types
0
0
1
1
1
1
1
1*
1
1
1
1
1
0
1
0
0
0
1
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1*
1*
1*
1*
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Depending on system volume
1
2
1
1
1
1
1
1*
1
1
1
1
* : optional (recommended)
▪
Additional items pressurised in function of installation
Material
Description
Required quantity
CONLCP
CONXP16
CONXP20
Connection pipe between solar panel rows
Connection between 2 CON15P16
Connection between 2 CON15P20
Number of rows - 1; Remove 1 FIXVBP per CONLCP
Additional CON15P16 needed
Additional CON15P20 needed
45
2
0
0
3
0
1
0
0
0
0
0
0
0
0
1
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1*
1*
1*
1*
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
1
1
1
1
1
Depending on system volume
0
0
1
1
0
0
1
1
1
1
1
1*
1
1
0
1
1
0
0
1
1
1
1
1
1
1
1*
1
1
0
1
1
other roof
types
→ Notes
46
→ Commercial terms and conditions
I. GENERAL
Our deliveries and services are exclusively subject to the following terms and conditions of sale and delivery, even
if the customer provides otherwise. The ordering party’s counter-confirmations in reliance on his commercial
terms and conditions or his terms and conditions of purchase apply only if they are consistent with these terms
and conditions of delivery. Acceptance of the goods is in any event deemed to constitute an acknowledgment of
our terms and conditions of sale and delivery. Any deviating modifications and amendments require our express
consent and must be made in writing to be legally valid. Our commercial terms and conditions can be found at
www.daikin-ce.com.
II. OFFER
Our offers are without engagement and non-binding. Any information about dimensions, weights, technical data,
quantities and delivery times is non-binding.
III. PLACING OF AN ORDER, CHANGE OF THE DELIVERABLE
1. Orders must be placed in writing (by letter, fax or email). We are deemed to have accepted an order not until
after we have confirmed in writing or actually executed that order. Any arrangement and agreement reached
verbally and by phone must be confirmed in writing.
2. We reserve the right to rescind the contract even after having accepted an order if information we have
obtained about the customer’s liquidity in the meantime suggests that the customer will not be able to pay for
the entire or for part of the order.
3. Having accepted an order, we also reserve the right to change and improve the service or deliverable, e.g. in
respect of its type and design, to the extent the customer can be reasonably expected to accept such changes
and improvements in consideration of our interests (e.g. delivery of an equivalent or more sophisticated
device). Such changes and improvements are deemed approved in advance.
4. The customer’s cancellation or change of an entire or of part of an order requires our written consent
and entitles us to charge the customer - in addition to the services already provided and costs accrued
- a (cancellation) fee equal to 20 % of the order value and at least € 250. For certain product
groups (e.g. multiple scroll, screw chiller), separate cancellation rules apply which can be found at
www.daikin-ce.com.
IV. PRICES AND TERMS OF PAYMENT
1. Prices are based on the price list, as amended from time to time, which is usually issued once a year. We reserve
the right to change prices also during a year.
2. Prices are understood to be net prices without any taxes, duties or charges in the quoted currency, including
packaging, ex our forwarding warehouse, unless otherwise indicated. We will not take back packaging and
packing material.
3. We will not accept any objections to invoices which are received more than two weeks after receipt of an
invoice. Unless otherwise indicated, invoices are due net 30 days from the invoice date; the payment date is
the date on which a payment is received by us. In case of late payment, we will charge default interest at a rate
of 12% p.a. In case of default, we may also demand all costs related to the collection of our claim, including,
without limitation, dunning and collection charges.
4. If payment by instalments has been agreed, the maturity date will be accelerated if the customer is in default
in respect of only one instalment.
5. We may make deliveries dependent on advance payment.
6. The customer may not withhold or set off payments in reliance on warranty or other claims.
V. DELIVERY TIME
1. Indicated delivery times are non-binding and reference times only, although we endeavour to meet indicated
deadlines. The customer has no right to insist on compliance with a certain delivery time. As a consequence,
delays in delivery will not entail any claims for damages and do not entitle the customer to rescind the contract.
The same holds true if delivery deadlines are not met due to force majeure, strike or other events outside our
control.
2. We will not accept penalty claims asserted by the customer under any circumstances.
3. Partial deliveries are permitted.
4. If the ordering party is in arrears on an earlier delivery, Daikin may withhold deliveries pending payment of the
earlier delivery and is not required to pay to the ordering party any damages in this respect.
VI. ACCEPTANCE OF DELIVERIES, TRANSFER OF RISK, DELAYED ACCEPTANCE
1. Unless otherwise agreed, deliveries are made CIP (Incoterms 2010) to the named destination
2. In principle, delivery CIP covers only minimum transport insurance. Additional transport insurance will be
purchased only if explicitly requested by customer and subject to a separate agreement and at the customer’s
cost and expense.
3. The customer must immediately check deliverables received by him or directly by his customers for any
transport damage, and he must record any damage to the packaging or the device in the delivery note and
shall refuse delivery towards the forwarding agent. If the customer finds out only later that goods are damaged,
the customer shall report any such damage to us, immediately, in no case later than three working days after
delivery; otherwise, any insurance claim may expire.
4. If the customer accepts goods with delay, we - notwithstanding our other rights - may charge the goods as
delivered or may otherwise dispose of them without setting a time limit. If we otherwise dispose of the goods,
the delivery time will recommence on the day we receive the customer’s written request calling for delivery
of the goods.
5. We may charge the customer for any costs incurred due to late acceptance, including, without limitation, any
storage costs.
VII. RESERVATION OF TITLE
1. We will retain title to goods delivered pending full payment of all claims arising from our business relationship
with the customer, even if the purchase price for specifically designated claims was paid. If our conditional
goods are processed, we will acquire title to the new item without consideration. If the goods delivered by us
are mixed, processed or combined with other items, the customer hereby assigns to us in proportion of the
value of our invoices an ownership or co-ownership right of the combined or new item, both in respect of the
interim and the final products.
2. The customer may resell goods delivered by us and the items created by processing, mixing or combining
these only in the ordinary course of business. The customer hereby assigns to us any claims arising from such
resale or from any other legal ground toward third parties, including, ancillary rights, in order to secure our future - claims that may arise from our business relationship. The customer must record the assignment of these
claims in his books not later than when the goods are resold.
3.
4.
5.
Before having paid the purchase price of an item, the customer may resell that item only if he simultaneously
informs the second buyer (end customer) that the resale proceeds have previously been assigned.
The customer may collect the assigned claims as long as he fulfils his payment obligations towards us according
to the terms of the contract. The customer may not otherwise dispose of the conditional goods (e.g.: transfer
of property by way of security, pledging).
The customer must immediately inform us of any attachment or other impairment of the conditional goods
and/or the assigned claims and explain to the third party that we have retained title to those goods. Any related
cost will be borne by the customer.
VIII. WARRANTY AND LIABILITY
A. Unless otherwise agreed and to the exclusion of any further claims, we are liable for any defects and the absence
of warranted qualities as follows:
1. Unless other wise indicated below, the warranty period is 36 months of the delivery date (delivery to the
forwarding agent). This does not affect the applicability of Section 924 of the Austrian Civil Code.
2. The customer may assert a warranty claim only if the equipment is both installed and put into operation
by Daikin or a company trained by Daikin according to the Daikin installation instructions and regularly
maintained according to the Daikin service notes. Refrigerating machines featuring screw-type compressors
include a 12-month warranty claim only if the machine was put into operation by Daikin itself. In case of
products designated “J&E Hall International for Daikin” the customer may assert an 18-month warranty claim.
For “Rotex” branded products generally a 24-month warranty period is valid except for following variations: 10
years for underfloor heating pipes and system plates, VA-piping and variosafe oil storage tanks. 5 years for solar
panels, variosystem and highcube oil tanks and variocistern rainwater tanks. 3 years for HPSU heat pump solar
unit and hot water storage tanks HYC, SCS and SC.
3. In a warranty event, we undertake, at our election, to replace or repair the defective goods or components. The
customer may not assert other warranty or guarantee claims whatsoever. Labour cost, travel times or other
costs will not be reimbursed.
4. No warranty and/or liability is accepted, unless the customer reports visible defects by giving written notice
within 3 working days of delivery and other defects without delay after these have been discovered.
5. In addition to paragraphs 2 and 4, no warranty and/or liability is accepted for defects that have been caused by
inadequate or improper use or treatment, failure to observe operating conditions or maintenance guideless,
excessive use or inadequate operating facilities or substitute materials.
6. Unless we are granted the required time and opportunity to take all necessary warranty measures, we are
released from any warranty claims and damages. If the customer continues to use defective goods, we warrant
and/or are liable only for the original defect. We will not reimburse any cost of repairs which are carried out
without our express prior consent. We disclaim any liability for the consequences of such repairs.
7. The warranty period for spare parts and other improvements is 6 months of delivery (delivery to the forwarding
agent).
8. If a defect is remedied, the warranty period will not recommence for the replaced or repaired components.
9. We may refuse to remedy defects as long as the customer is in default with his payment obligations. The
customer has no right to withhold payments, even if he gave justified notice of defects.
10. If third-party products are delivered and installed, warranty is restricted to assigning the warranty claims we
may assert against the supplier of the third-party product. The customer may not assert any other warranty
claims and may particularly not claim a price reduction.
B. We are liable for damage only if we demonstrably acted with intent or gross negligence. We disclaim any
liability for slight negligence. We are particularly not liable for consequential damage (e.g. idle times due to wrong
deliveries) and financial loss, lost profit, unachieved savings, loss of interest and any damage suffered from thirdparty claims against the customer, unless the foregoing is attributable to our intent or gross negligence. If damage
is attributable to the defective condition of goods delivered by us, we are liable only to the extent the producer
or upstream supplier is liable to us. Our liability does in any case not exceed the invoice value of the incriminated
goods.
IX. RETURNED GOODS
1. Goods can be returned and exchanged only upon our express and written consent. We accept returned goods
only with a minimum net value of € 100 and a maximum net value of € 50.000 per return item quantity and
only provided that those goods are not damaged, have not been used, are in original packaging and are fit for
resale. In particular, returns of already installed units (including chillers) and returns of any made to order units
as well as spare parts are not permitted.
2. The customer shall complete the “Request for Goods Return”-form (available at the DENV Extranet,
http:¥¥extranet.daikineurope.com) and send it to us to the fax number or email address provided by us within
10 calendar days after delivery, otherwise we will not accept the return.
3. Goods must be returned freight paid at the risk of customer to the destination indicated by us.
4.
In every case of a return, a maximum of 80% of the net price charged by us to the customer will
be credited. All standard returns will be subject to a restocking / administration charge of 20 % of the net price.
5. All returns will be inspected by us. If goods are returned wrongly (i.e. not in compliance with paragraph 1.
above), we may refuse the returns and have them returned back to the customer at the customer’s risk and
costs. Alternatively, we may charge a higher restocking / administration fee than the above mentioned 20%.
6. Any credit notes whatsoever will exclusively be set off against future deliveries.
X. PLACE OF JURISDICTION, APPLICABLE LAW
1. All disputes arising from or in connection with this Agreement shall be exclusively referred to the courts in
Vienna.
2. All contracts concluded by us and all disputes arising in connection with those contracts shall be governed
by and construed in accordance with Austrian law without giving effect to its conflict of law rules and the UN
Sales Convention.
XI. SEVERABILITY
Should any term of these commercial terms and conditions or of the contract concluded between us and the
customer be invalid or ineffective, this shall not affect the remaining terms hereof or thereof. Invalid terms shall be
replaced by lawful terms which closest reflect the parties’ intent.
The Daikin Commercial Terms & Conditions are also available at www.daikin-ce.com
Campus 21, Europaring F12/402 · A-2345 Brunn am Gebirge, Austria
phone +43 2236 32557, fax +43 2236 32557-900, office@daikin-ce.com, www.daikin-ce.com
47