- Computers & electronics
- Computer components
- System components
- Internal hard drives
- Seagate
- 2TB SAS 3.5"
- Product Manual
advertisement
Product Manual
Constellation
®
ES.2 SAS
Standard Model
ST33000650SS
ST32000645SS
Self-Encrypting Drive Model
ST33000651SS
ST32000646SS
SED FIPS 140-2 Model
ST33000652SS
ST32000647SS
100628615
Rev. G
February 2012
Revision
Rev. A
Rev. B
Rev. C
Rev. D
Rev. E
Rev. F
Rev. G
Date
11/29/10
02/23/11
03/23/11
04/28/11
08/11/11
09/22/11
02/09/12
Revision history
Sheets affected or comments
Initial release
6-8, 10, 22, 27, 32 42 & 46-48.
8-9, 13-14, 35-36 & 40.
fc, 2, 23 & 47.
2, 11, 34-35, 48 & back cover.
54.
fc, 2, 9-11, 23-24, 27, 30, 37-38, 40-42, 52, 55 & 59.
© 2012, Seagate Technology LLC All rights reserved.
Publication number: 100628615, Rev. G February 2012
Seagate, Seagate Technology and the Wave logo are registered trademarks of Seagate Technology
LLC in the United States and/or other countries. Constellation ES.2 and SeaTools are either trademarks or registered trademarks of Seagate Technology LLC or one of its affiliated companies in the
United States and/or other countries. The FIPS logo is a certification mark of NIST, which does not imply product endorsement by NIST, the U.S., or Canadian governments. All other trademarks or registered trademarks are the property of their respective owners.
No part of this publication may be reproduced in any form without written permission of Seagate
Technology LLC. Call 877-PUB-TEK1 (877-782-8351) to request permission.
One gigabyte, or GB, equals one billion bytes and one terabyte, or TB, equals one trillion bytes.
Your computer's operating system may use a different standard of measurement and report a lower capacity. In addition, some of the listed capacity is used for formatting and other functions, and thus will not be available for data storage. Seagate reserves the right to change, without notice, product offerings or specifications.
Contents
European Union Restriction of Hazardous Substances (RoHS) . . . . . . . . . . . . . 5
China Restriction of Hazardous Substances (RoHS) Directive . . . . . . . . . . . . . 5
Format command execution time for 512-byte sectors (minutes) . . . . . . . . . . . 11
Annualized Failure Rate (AFR) and Mean Time Between Failure (MTBF) . . . . 15
7.1
TM power management. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
7.3.3
Constellation ES.2 SAS Product Manual, Rev. G i
Setting and determining the current Type Level. . . . . . . . . . . . . . . . . . . . . . . . . 46
12.3.2
ii Constellation ES.2 SAS Product Manual, Rev. G
12.7
Constellation ES.2 SAS Product Manual, Rev. G iii
iv Constellation ES.2 SAS Product Manual, Rev. G
List of Figures
Figure 16.
Constellation ES.2 SAS Product Manual, Rev. G v
vi Constellation ES.2 SAS Product Manual, Rev. G
1.0
Seagate Technology support services
SEAGATE ONLINE SUPPORT and SERVICES
For information regarding products and services, visit http://www.seagate.com/www/en-us/about/contact_us/
Available services include:
Presales & Technical support
Global Support Services telephone numbers & business hours
Authorized Service Centers
For information regarding Warranty Support, visit http://www.seagate.com/www/en-us/support/warranty_&_returns_assistance
For information regarding Data Recovery Services, visit http://www.i365.com
For Seagate OEM & Distribution partner portal, visit https://direct.seagate.com/portal/system
For Seagate reseller portal, visit http://spp.seagate.com
Constellation ES.2 SAS Product Manual, Rev. G 1
2.0
Scope
This manual describes Seagate Technology ® LLC, Constellation ® ES.2 SAS (Serial Attached SCSI) disk drives.
Constellation ES.2 drives support the SAS Protocol specifications to the extent described in this manual. The
SAS Interface Manual (part number 100293071) describes the general SAS characteristics of this and other
Seagate SAS drives. The Self-Encrypting Drive Reference Manual, part number 100515636, describes the interface, general operation, and security features available on Self-Encrypting Drive models.
Product data communicated in this manual is specific only to the model numbers listed in this manual. The data listed in this manual may not be predictive of future generation specifications or requirements. If you are designing a system which will use one of the models listed or future generation products and need further assistance, please contact your Field Applications Engineer (FAE) or our global support services group as
Unless otherwise stated, the information in this manual applies to standard and Self-Encrypting Drive models.
Model Number
ST33000650SS
ST33000651SS
ST33000652SS
ST32000645SS
ST32000646SS
ST32000647SS
Self-Encrypting Drive (SED)
No
Yes
Yes
No
Yes
Yes
FIPS 140-2 Level 2
No
No
Yes
No
No
Yes
Note.
Previous generations of Seagate Self-Encrypting Drive models were called Full Disk Encryption
(FDE) models before a differentiation between drive-based encryption and other forms of encryption was necessary.
Note.
The Self-Encrypting Drive models indicated on the cover of this product manual have provisions for
“Security of Data at Rest” based on the standards defined by the Trusted Computing Group (see www.trustedcomputinggroup.org).
For more information on FIPS 140-2 Level 2 certification see Section 8.0 on page 38.
2 Constellation ES.2 SAS Product Manual, Rev. G
3.0
Applicable standards and reference documentation
The drives documented in this manual have been developed as system peripherals to the highest standards of design and construction. The drives depends on host equipment to provide adequate power and environment for optimum performance and compliance with applicable industry and governmental regulations. Special attention must be given in the areas of safety, power distribution, shielding, audible noise control, and temperature regulation. In particular, the drive must be securely mounted to guarantee the specified
performance characteristics. Mounting by bottom holes must meet the requirements of Section 11.3.
3.1
Standards
The Constellation ES.2 family complies with Seagate standards as noted in the appropriate sections of this manual and the Seagate SAS Interface Manual, part number 100293071.
The drives are recognized in accordance with UL 60950-1 as tested by UL, CSA 60950-1 as tested by CSA, and EN60950-1 as tested by TUV.
The security features of Self-Encrypting Drive models are based on the “TCG Storage Architecture Core
Specification” and the “TCG Storage Workgroup Security Subsystem Class: Enterprise_A” specification with additional vendor-unique features as noted in this product manual.
3.1.1
Electromagnetic compatibility
The drive, as delivered, is designed for system integration and installation into a suitable enclosure prior to use. The drive is supplied as a subassembly and is not subject to Subpart B of Part 15 of the FCC Rules and
Regulations nor the Radio Interference Regulations of the Canadian Department of Communications.
The design characteristics of the drive serve to minimize radiation when installed in an enclosure that provides reasonable shielding. The drive is capable of meeting the Class B limits of the FCC Rules and Regulations of the Canadian Department of Communications when properly packaged; however, it is the user’s responsibility to assure that the drive meets the appropriate EMI requirements in their system. Shielded I/O cables may be required if the enclosure does not provide adequate shielding. If the I/O cables are external to the enclosure, shielded cables should be used, with the shields grounded to the enclosure and to the host controller.
3.1.1.1
Electromagnetic susceptibility
As a component assembly, the drive is not required to meet any susceptibility performance requirements. It is the responsibility of those integrating the drive within their systems to perform those tests required and design their system to ensure that equipment operating in the same system as the drive or external to the system does not adversely affect the performance of the drive. See Table 2, DC power requirements.
Constellation ES.2 SAS Product Manual, Rev. G 3
3.1.2
Electromagnetic compliance
Seagate uses an independent laboratory to confirm compliance with the directives/standards for CE Marking and C-Tick Marking. The drive was tested in a representative system for typical applications. The selected system represents the most popular characteristics for test platforms. The system configurations include:
• Typical current use microprocessor
• Keyboard
• Monitor/display
• Printer
• Mouse
Although the test system with this Seagate model complies with the directives/standards, we cannot guarantee that all systems will comply. The computer manufacturer or system integrator shall confirm EMC compliance and provide the appropriate marking for their product.
Electromagnetic compliance for the European Union
If this model has the CE Marking it complies with the European Union requirements of the Electromagnetic
Compatibility Directive 2004/108/EC as put into place on 20 July 2007.
Australian C-Tick
If this model has the C-Tick Marking it complies with the Australia/New Zealand Standard AS/NZ CISPR22 and meets the Electromagnetic Compatibility (EMC) Framework requirements of Australia’s Spectrum
Management Agency (SMA).
Korean KCC
If these drives have the Korean Communications Commission (KCC) logo, they comply with paragraph 1 of
Article 11 of the Electromagnetic Compatibility control Regulation and meet the Electromagnetic Compatibility
(EMC) Framework requirements of the Radio Research Laboratory (RRL) Communications Commission,
Republic of Korea.
These drives have been tested and comply with the Electromagnetic Interference/Electromagnetic
Susceptibility (EMI/EMS) for Class B products. Drives are tested in a representative, end-user system by a
Korean-recognized lab.
• Family name:
• Certificate number:
Constellation ES SAS
STX-ST33000650SS
• Manufacturing date: July 2, 2010 (Date of Certification)
• Manufacturer/nationality: USA, Singapore and China
Taiwanese BSMI
If this model has two Chinese words meaning “EMC certification” followed by an eight digit identification number, as a Marking, it complies with Chinese National Standard (CNS) 13438 and meets the
Electromagnetic Compatibility (EMC) Framework requirements of the Taiwanese Bureau of Standards,
Metrology, and Inspection (BSMI).
4 Constellation ES.2 SAS Product Manual, Rev. G
3.1.3
European Union Restriction of Hazardous Substances (RoHS)
The European Union Restriction of Hazardous Substances (RoHS) Directive, restricts the presence of chemical substances, including Lead, Cadmium, Mercury, Hexavalent Chromium, PBB and PBDE, in electronic products, effective July 2006. This drive is manufactured with components and materials that comply with the RoHS Directive.
A number of parts and materials in Seagate products are procured from external suppliers. We rely on the representations of our suppliers regarding the presence of RoHS substances in these parts and materials. Our supplier contracts require compliance with our chemical substance restrictions, and our suppliers document their compliance with our requirements by providing material content declarations for all parts and materials for the disk drives documented in this publication. Current supplier declarations include disclosure of the inclusion of any RoHS-regulated substance in such parts or materials.
Seagate also has internal systems in place to ensure ongoing compliance with the RoHS Directive and all laws and regulations which restrict chemical content in electronic products. These systems include standard operating procedures that ensure that restricted substances are not utilized in our manufacturing operations, laboratory analytical validation testing, and an internal auditing process to ensure that all standard operating procedures are complied with.
3.1.4
China Restriction of Hazardous Substances (RoHS) Directive
This product has an Environmental Protection Use Period (EPUP) of 20 years. The following table contains information mandated by China's "Marking Requirements for Control of Pollution
Caused by Electronic Information Products" Standard.
"O" indicates the hazardous and toxic substance content of the part (at the homogenous material level) is lower than the threshold defined by the China RoHS MCV Standard.
"X" indicates the hazardous and toxic substance content of the part (at the homogenous material level) is over the threshold defined by the China RoHS MCV Standard.
Constellation ES.2 SAS Product Manual, Rev. G 5
3.2
Reference documents
SAS Interface Manual
Seagate part number: 100293071
SCSI Commands Reference Manual
Seagate part number: 100293068
Self-Encrypting Drives Reference Manual
Seagate part number: 100515636
ANSI SAS Documents
SFF-8323
SFF-8460
SFF-8470
SFF-8482
3.5” Drive Form Factor with Serial Connector
HSS Backplane Design Guidelines
Multi Lane Copper Connector
SAS Plug Connector
ANSI INCITS.xxx
Serial Attached SCSI (SAS-2) Standard (T10/1562-D)
ISO/IEC 14776-xxx SCSI Architecture Model-3 (SAM-4) Standard (T10/1561-D)
ISO/IEC 14776-xxx SCSI Primary Commands-3 (SPC-4) Standard (T10/1416-D)
ISO/IEC 14776-xxx SCSI Block Commands-2 (SBC-3) Standard (T10/1417-D)
ANSI Small Computer System Interface (SCSI) Documents
X3.270-1996 (SCSI-3) Architecture Model
Trusted Computing Group (TCG) Documents (apply to Self-Encrypting Drive models only)
TCG Storage Architecture Core Specification, Rev. 1.0
TCG Storage Security Subsystem Class Enterprise Specification, Rev. 1.0
Specification for Acoustic Test Requirement and Procedures
Seagate part number: 30553-001
In case of conflict between this document and any referenced document, this document takes precedence.
6 Constellation ES.2 SAS Product Manual, Rev. G
4.0
General description
Constellation ES.2 drives provide high performance, high capacity data storage for a variety of systems including engineering workstations, network servers, mainframes, and supercomputers. The Serial Attached
SCSI interface is designed to meet next-generation computing demands for performance, scalability, flexibility and high-density storage requirements.
Constellation ES.2 drives are random access storage devices designed to support the Serial Attached SCSI
Protocol as described in the ANSI specifications, this document, and the SAS Interface Manual (part number
100293071) which describes the general interface characteristics of this drive. Constellation ES.2 drives are classified as intelligent peripherals and provide level 2 conformance (highest level) with the ANSI SCSI-1 standard. The SAS connectors, cables and electrical interface are compatible with Serial ATA (SATA), giving future users the choice of populating their systems with either SAS or SATA hard disk drives. This allows you to continue to leverage your existing investment in SCSI while gaining a 6Gb/s serial data transfer rate.
The Self-Encrypting Drive models indicated on the cover of this product manual have provisions for “Security of Data at Rest” based on the standards defined by the Trusted Computing Group
(see www.trustedcomputinggroup.org).
The head and disk assembly (HDA) is sealed at the factory. Air recirculates within the HDA through a nonreplaceable filter to maintain a contamination-free HDA environment.
Note.
Never disassemble the HDA and do not attempt to service items in the sealed enclosure (heads, media, actuator, etc.) as this requires special facilities. The drive does not contain user-replaceable parts. Opening the HDA for any reason voids your warranty.
Constellation ES.2 drives use a dedicated load/unload zone at the outermost radius of the media to eliminate the possibility of destroying or degrading data by landing in the data zone. The heads automatically go to the ramp load/unload when power is removed from the drive.
An automatic shipping lock prevents potential damage to the heads and discs that results from movement during shipping and handling. The shipping lock disengages and the head load process begins when power is applied to the drive.
Constellation ES.2 drives decode track 0 location data from the servo data embedded on each surface to eliminate mechanical transducer adjustments and related reliability concerns.
The drives also use a high-performance actuator assembly with a low-inertia, balanced, patented, straight arm design that provides excellent performance with minimal power dissipation.
Note.
Seagate recommends validating your configuration with the selected HBA/RAID controller manufacturer to ensure full 3TB capacity capabilities.
Constellation ES.2 SAS Product Manual, Rev. G 7
4.1
Standard features
Constellation ES.2 drives have the following standard features:
• Perpendicular recording technology
• 1.5 / 3.0 / 6.0
Gb Serial Attached SCSI (SAS) interface
• Integrated dual port SAS controller supporting the SCSI protocol
• Support for SAS expanders and fanout adapters
• Firmware downloadable using the SAS interface
• 128 - deep task set (queue)
• Supports up to 32 initiators
• Jumperless configuration.
• User-selectable logical block size (512, 520 or 528 bytes per logical block).
• Industry standard 3.5-inch dimensions
• Programmable logical block reallocation scheme
• Flawed logical block reallocation at format time
• Programmable auto write and read reallocation
• Reallocation of defects on command (Post Format)
• ECC maximum burst correction length of 400 bits
• No preventive maintenance or adjustments required
• Embedded servo design
• Dedicated head load/unload zone
• Self diagnostics performed when power is applied to the drive
• Vertical, horizontal, or top down mounting
• 64 MB data buffer (see Section 5.5).
• Drive Self Test (DST)
• Background Media Scan (BMS)
• Idle Read After Write (IRAW)
• Power Save
Constellation ® ES.2 SAS Self-Encrypting Drive models have the following additional features:
• Automatic data encryption/decryption
• Controlled access
• Random number generator
• Drive locking
• 16 independent data bands
• Cryptographic erase of user data for a drive that will be repurposed or scrapped
• Authenticated firmware download
4.2
Media description
The media used on the drive has a aluminum substrate coated with a thin film magnetic material, overcoated with a proprietary protective layer for improved durability and environmental protection.
4.3
Performance
• Programmable multi-segmentable cache buffer
• 600MB/s maximum instantaneous data transfers.
• 7200 RPM spindle. Average latency = 4.16ms
• Background processing of queue
• Supports start and stop commands (spindle stops spinning)
• Adaptive seek velocity; improved seek performance
Note.
There is no significant performance difference between Self-Encrypting Drive and standard (non-
Self-Encrypting Drive) models.
8 Constellation ES.2 SAS Product Manual, Rev. G
4.4
Reliability
• Annualized Failure Rate (AFR) of 0.73%
• Mean time between failures (MTBF) of 1,200,000 hours
• Balanced low mass rotary voice coil actuator
• Incorporates industry-standard Self-Monitoring Analysis and Reporting Technology (S.M.A.R.T.)
4.5
Formatted capacities
Standard OEM models are formatted to 512 bytes per block. The block size is selectable at format time and must be a multiple of 4 bytes. Users having the necessary equipment may modify the data block size before issuing a format command and obtain different formatted capacities than those listed.
To provide a stable target capacity environment and at the same time provide users with flexibility if they choose, Seagate recommends product planning in one of two modes:
1. Seagate designs specify capacity points at certain block sizes that Seagate guarantees current and future products will meet. We recommend customers use this capacity in their project planning, as it ensures a stable operating point with backward and forward compatibility from generation to generation. The current guaranteed operating points for this product are:
Capacity (Blocks)
ST33000650SS
ST33000651SS
ST33000652SS
Sector Size Decimal
512 5,860,533,168
520
5,736,538,480
528 5,578,747,784
Hex
15D50A3B0h
155ECA170h
14C84EF88h
ST32000645SS
ST32000646SS
ST32000647SS
Decimal
3,907,029,168
3,824,358,992
3,719,165,192
Hex
E8E088B0h
E3F31650h
DDADF508h
4.6
Programmable drive capacity
Using the Mode Select command, the drive can change its capacity to something less than maximum. See the
Mode Select (6) parameter list table in the SAS Interface Manual, part number 100293071. A value of zero in the Number of Blocks field indicates that the drive will not change the capacity it is currently formatted to have.
A number other than zero and less than the maximum number of LBAs in the Number of Blocks field changes the total drive capacity to the value in the Number of Blocks field. A value greater than the maximum number of
LBAs is rounded down to the maximum capacity.
4.7
Factory-installed options
You may order the following items which are incorporated at the manufacturing facility during production or packaged before shipping. Some of the options available are (not an exhaustive list of possible options):
• Other capacities can be ordered depending on sparing scheme and sector size requested.
• Single-unit shipping pack. The drive is normally shipped in bulk packaging to provide maximum protection against transit damage. Units shipped individually require additional protection as provided by the single unit shipping pack. Users planning single unit distribution should specify this option.
• The Safety and Regulatory Agency Specifications, part number 75789512, is usually included with each standard OEM drive shipped, but extra copies may be ordered.
Constellation ES.2 SAS Product Manual, Rev. G 9
5.0
Performance characteristics
This section provides detailed information concerning performance-related characteristics and features of
Constellation ES.2 drives.
5.1
Internal drive characteristics
ST33000650SS
ST33000651SS
Drive capacity
Read/write data heads
Bytes per track
Bytes per surface
ST33000652SS
3
10
1,419,776
300,000
Tracks per surface (total) 284,399
Tracks per inch
Peak bits per inch
270,000
1,638,000
Areal density
Internal data rate disk rotation speed
Avg rotational latency
444
68.7 - 155
7200
4.16
ST32000645SS
ST32000646SS
ST32000647SS
2
7/8
1,419,776
300,000
284,399
270,000
1,638,000
444
68.7 - 155
7200
4.16
TB (formatted, rounded off value)
Bytes (average, rounded off values)
MB (unformatted, rounded off value)
Tracks (user accessible)
TPI (average)
BPI
Gb/in
2
MB/s (variable with zone) rpm ms
5.2
Seek performance characteristics
and SAS Interface Manual (part number
100293071) for additional timing details.
5.2.1
Access time
Not including controller overhead
1
,
2
(ms)
Read
Average Typical
3
,
4
8.3
Single track Typical 3,4 0.5
Full stroke Typical 3,4 15.5
Write
9.3
0.5
16.2
Including controller overhead
Read
8.5
0.7
15.7
Write
9.5
0.7
16.4
1, 2 (ms)
1.
Execution time measured from receipt of the Command to the Response.
2.
Assumes no errors and no sector has been relocated.
3.
Typical access times are measured under nominal conditions of temperature, voltage, and horizontal orientation as measured on a representative sample of drives.
4.
Access time = controller overhead + average seek time and applies to all data transfer commands.
Access to data = access time + latency time.
10 Constellation ES.2 SAS Product Manual, Rev. G
5.2.2
Format command execution time for 512-byte sectors (minutes)
Maximum (with verify)
Maximum (without verify)
3TB models
827
402
2TB models
561
270
Execution time measured from receipt of the last byte of the Command Descriptor Block (CDB) to the request for a Status Byte Transfer to the Initiator (excluding connect/disconnect).
When changing sector sizes, the format times shown above may need to be increased by 30 minutes.
5.2.3
General performance characteristics
Minimum sector interleave
Data buffer to/from disk media (one 512-byte logical block)*
Sustained transfer rate
SAS Interface maximum instantaneous transfer rate
1 to 1
113 to 239 MB/s
68.7 to 155 MB/s
600MB/s* per port
(dual port = 1200MB/s*)
Logical block sizes
512 (default), 520 or 528.
Read/write consecutive sectors on a track
Flaw reallocation performance impact (for flaws reallocated at format time using the spare sectors per sparing zone reallocation scheme.)
Average rotational latency
Yes
Negligible
4.16ms
*Assumes no errors and no relocated logical blocks. Rate measured from the start of the first logical block transfer to or from the host.
5.3
Start/stop time
The drive accepts the commands listed in the SAS Interface Manual less than 3 seconds after DC power has been applied.
If the drive receives a NOTIFY (ENABLE SPINUP) primitive through either port and has not received a START
STOP UNIT command with the START bit equal to 0, the drive becomes ready for normal operations within 30 seconds (excluding the error recovery procedure).
If the drive receives a START STOP UNIT command with the START bit equal to 0 before receiving a NOTIFY
(ENABLE SPINUP) primitive, the drive waits for a START STOP UNIT command with the START bit equal to 1.
After receiving a START STOP UNIT command with the START bit equal to 1, the drive waits for a NOTIFY
(ENABLE SPINUP) primitive. After receiving a NOTIFY (ENABLE SPINUP) primitive through either port, the drive becomes ready for normal operations within 30 seconds (excluding the error recovery procedure).
If the drive receives a START STOP UNIT command with the START bit and IMMED bit equal to 1 and does not receive a NOTIFY (ENABLE SPINUP) primitive within 5 seconds, the drive fails the START STOP UNIT command.
The START STOP UNIT command may be used to command the drive to stop the spindle. Stop time is 20 seconds (maximum) from removal of DC power. SCSI stop time is 20 seconds. There is no power control switch on the drive.
Constellation ES.2 SAS Product Manual, Rev. G 11
5.4
Prefetch/multi-segmented cache control
The drive provides a prefetch (read look-ahead) and multi-segmented cache control algorithms that in many cases can enhance system performance. Cache refers to the drive buffer storage space when it is used in cache operations. To select this feature, the host sends the Mode Select command with the proper values in the applicable bytes in page 08h. Prefetch and cache operations are independent features from the standpoint that each is enabled and disabled independently using the Mode Select command; however, in actual
All default cache and prefetch mode parameter values (Mode Page 08h) for standard OEM versions of this
drive family are given in Table 9.
5.5
Cache operation
Note.
Refer to the SAS Interface Manual for more detail concerning the cache bits.
Of the 64MB physical buffer space in the drive, approximately 30,000 kbytes can be used as a cache. The buffer is divided into logical segments from which data is read and to which data is written.
The drive keeps track of the logical block addresses of the data stored in each segment of the buffer. If the cache is enabled (see RCD bit in the SAS Interface Manual ), data requested by the host with a read command is retrieved from the buffer, if possible, before any disk access is initiated. If cache operation is not enabled, the buffer is still used, but only as circular buffer segments during disk medium read operations (disregarding
Prefetch operation for the moment). That is, the drive does not check in the buffer segments for the requested read data, but goes directly to the medium to retrieve it. The retrieved data merely passes through some buffer segment on the way to the host. All data transfers to the host are in accordance with buffer-full ratio rules. See the explanation provided with the information about Mode Page 02h (disconnect/reconnect control) in the SAS
Interface Manual .
The following is a simplified description of the prefetch/cache operation:
Case A —read command is received and all of the requested logical blocks are already in the cache:
1. Drive transfers the requested logical blocks to the initiator.
Case B —A Read command requests data, and at least one requested logical block is not in any segment of the cache:
1. The drive fetches the requested logical blocks from the disk and transfers them into a segment, and then from there to the host in accordance with the Mode Select Disconnect/Reconnect parameters, page 02h.
2. If the prefetch feature is enabled, refer to section 5.5.2 for operation from this point.
Each cache segment is actually a self-contained circular buffer whose length is an integer number of logical blocks. The drive dynamically creates and removes segments based on the workload. The wrap-around capability of the individual segments greatly enhances the cache’s overall performance.
Note.
The size of each segment is not reported by Mode Sense command page 08h, bytes 14 and 15.
The value 0XFFFF is always reported regardless of the actual size of the segment. Sending a size specification using the Mode Select command (bytes 14 and 15) does not set up a new segment size. If the STRICT bit in Mode page 00h (byte 2, bit 1) is set to one, the drive responds as it does for any attempt to change an unchangeable parameter.
12 Constellation ES.2 SAS Product Manual, Rev. G
5.5.1
Caching write data
Write caching is a write operation by the drive that makes use of a drive buffer storage area where the data to be written to the medium is stored while the drive performs the Write command.
If read caching is enabled (RCD=0), then data written to the medium is retained in the cache to be made available for future read cache hits. The same buffer space and segmentation is used as set up for read functions. The buffer segmentation scheme is set up or changed independently, having nothing to do with the state of RCD. When a write command is issued, if RCD=0, the cache is first checked to see if any logical blocks that are to be written are already stored in the cache from a previous read or write command. If there are, the respective cache segments are cleared. The new data is cached for subsequent Read commands.
If the number of write data logical blocks exceed the size of the segment being written into, when the end of the segment is reached, the data is written into the beginning of the same cache segment, overwriting the data that was written there at the beginning of the operation; however, the drive does not overwrite data that has not yet been written to the medium.
If write caching is enabled (WCE=1), then the drive may return Good status on a write command after the data has been transferred into the cache, but before the data has been written to the medium. If an error occurs while writing the data to the medium, and Good status has already been returned, a deferred error will be generated.
The Synchronize Cache command may be used to force the drive to write all cached write data to the medium.
Upon completion of a Synchronize Cache command, all data received from previous write commands will have
been written to the medium. Table 9 shows the mode default settings for the drive.
5.5.2
Prefetch operation
If the Prefetch feature is enabled, data in contiguous logical blocks on the disk immediately beyond that which was requested by a Read command are retrieved and stored in the buffer for immediate transfer from the buffer to the host on subsequent Read commands that request those logical blocks (this is true even if cache operation is disabled). Though the prefetch operation uses the buffer as a cache, finding the requested data in the buffer is a prefetch hit, not a cache operation hit.
To enable Prefetch, use Mode Select page 08h, byte 12, bit 5 (Disable Read Ahead - DRA bit). DRA bit = 0 enables prefetch.
The drive does not use the Max Prefetch field (bytes 8 and 9) or the Prefetch Ceiling field (bytes 10 and 11).
When prefetch (read look-ahead) is enabled (enabled by DRA = 0), the drive enables prefetch of contiguous blocks from the disk when it senses that a prefetch hit will likely occur. The drive disables prefetch when it decides that a prefetch hit is not likely to occur.
Constellation ES.2 SAS Product Manual, Rev. G 13
6.0
Reliability specifications
The following reliability specifications assume correct host and drive operational interface, including all interface timings, power supply voltages, environmental requirements and drive mounting constraints.
Seek error rate:
Read Error Rates
1
Recovered Data
Unrecovered Data
Miscorrected Data
Interface error rate:
Preventive maintenance:
Less than 10 errors in 10 8 seeks
Less than 10 errors in 10 12 bits transferred (OEM default settings)
Less than 1 sector in 10 15 bits transferred
Less than 1 sector in 10
Less than 1 error in 10
Mean Time Between Failure (MTBF): 1,200,000 hours
Annualized Failure Rate (AFR): 0.73%
None required
12
21 bits transferred
bits transferred
1.
Error rate specified with automatic retries and data correction with ECC enabled and all flaws reallocated.
6.1
Error rates
The error rates stated in this manual assume the following:
• Errors caused by host system failures are excluded from error rate computations.
• Assume random data.
• Default OEM error recovery settings are applied. This includes AWRE, ARRE, full read retries, full write retries and full retry time.
6.1.1
Recoverable Errors
Recoverable errors are those detected and corrected by the drive, and do not require user intervention.
Recoverable Data errors will use correction, although ECC on-the-fly is not considered for purposes of recovered error specifications.
Recovered Data error rate is determined using read bits transferred for recoverable errors occurring during a read, and using write bits transferred for recoverable errors occurring during a write.
6.1.2
Unrecoverable Errors
An unrecoverable data error is defined as a failure of the drive to recover data from the media. These errors occur due to head/media or write problems. Unrecoverable data errors are only detected during read operations, but not caused by the read. If an unrecoverable data error is detected, a MEDIUM ERROR (03h) in the Sense Key will be reported. Multiple unrecoverable data errors resulting from the same cause are treated as 1 error.
14 Constellation ES.2 SAS Product Manual, Rev. G
6.1.3
Seek errors
A seek error is defined as a failure of the drive to position the heads to the addressed track. After detecting an initial seek error, the drive automatically performs an error recovery process. If the error recovery process fails, a seek positioning error (Error code = 15h or 02h) will be reported with a Hardware error (04h) in the Sense
Key. Recoverable seek errors are specified at Less than 10 errors in 10 8 seeks. Unrecoverable seek errors
(Sense Key = 04h) are classified as drive failures.
6.1.4
Interface errors
An interface error is defined as a failure of the receiver on a port to recover the data as transmitted by the device port connected to the receiver. The error may be detected as a running disparity error, illegal code, loss of word sync, or CRC error.
6.2
Reliability and service
You can enhance the reliability of Constellation ES.2 disk drives by ensuring that the drive receives adequate
the service life of the drive. Section 11.2 provides recommended air-flow information.
6.2.1
Annualized Failure Rate (AFR) and Mean Time Between Failure (MTBF)
The production disk drive shall achieve an AFR of 0.73% (MTBF of 1,200,000 hours) when operated in an
(decrease the MTBF). The AFR (MTBF) is a population statistic not relevant to individual units.
The AFR (MTBF) specification is based on the following assumptions for Enterprise Storage System environments:
• 8760 power-on hours per year.
• 250 average on/off cycles per year.
• Operations at nominal voltages.
decrease the MTBF.
6.2.2
Preventive maintenance
No routine scheduled preventive maintenance is required.
6.2.3
Hot plugging the drive
When a disk is powered on by switching the power or hot plugged, the drive runs a self test before attempting to communicate on its’ interfaces. When the self test completes successfully, the drive initiates a Link Reset starting with OOB. An attached device should respond to the link reset. If the link reset attempt fails, or any time the drive looses sync, the drive initiated link reset. The drive will initiate link reset once per second but alternates between port A and B. Therefore each port will attempt a link reset once per 2 seconds assuming both ports are out of sync.
If the self-test fails, the drive does not respond to link reset on the failing port.
Note.
It is the responsibility of the systems integrator to assure that no temperature, energy, voltage hazard, or ESD potential hazard is presented during the hot connect/disconnect operation. Discharge the static electricity from the drive carrier prior to inserting it into the system.
Constellation ES.2 SAS Product Manual, Rev. G 15
Caution.
The drive motor must come to a complete stop prior to changing the plane of operation. This time is required to insure data integrity.
6.2.4
S.M.A.R.T.
S.M.A.R.T. is an acronym for Self-Monitoring Analysis and Reporting Technology. This technology is intended to recognize conditions that indicate imminent drive failure and is designed to provide sufficient warning of a failure to allow you to back up the data before an actual failure occurs.
Note.
The drive’s firmware monitors specific attributes for degradation over time but can’t predict instantaneous drive failures.
Each monitored attribute has been selected to monitor a specific set of failure conditions in the operating performance of the drive and the thresholds are optimized to minimize “false” and “failed” predictions.
Controlling S.M.A.R.T.
The operating mode of S.M.A.R.T. is controlled by the DEXCPT and PERF bits on the Informational Exceptions
Control mode page (1Ch). Use the DEXCPT bit to enable or disable the S.M.A.R.T. feature. Setting the
DEXCPT bit disables all S.M.A.R.T. functions. When enabled, S.M.A.R.T. collects on-line data as the drive performs normal read and write operations. When the PERF bit is set, the drive is considered to be in “On-line
Mode Only” and will not perform off-line functions.
You can measure off-line attributes and force the drive to save the data by using the Rezero Unit command.
Forcing S.M.A.R.T. resets the timer so that the next scheduled interrupt is in one hour.
You can interrogate the drive through the host to determine the time remaining before the next scheduled measurement and data logging process occurs. To accomplish this, issue a Log Sense command to log page
0x3E. This allows you to control when S.M.A.R.T. interruptions occur. Forcing S.M.A.R.T. with the RTZ command resets the timer.
Performance impact
S.M.A.R.T. attribute data is saved to the disk so that the events that caused a predictive failure can be recreated. The drive measures and saves parameters once every one hour subject to an idle period on the drive interfaces. The process of measuring off-line attribute data and saving data to the disk is interruptable.
The maximum on-line only processing delay is summarized below:
Maximum processing delay
S.M.A.R.T. delay times
On-line only delay
DEXCPT = 0, PERF = 1
210 ms
Fully-enabled delay
DEXCPT = 0, PERF = 0
75 ms
Reporting control
Reporting is controlled by the MRIE bits in the Informational Exceptions Control mode page (1Ch). An example, if the MRIE is set to one, the firmware will issue to the host an 01-5D00 sense code. The FRU field contains the type of predictive failure that occurred. The error code is preserved through bus resets and power cycles.
Determining rate
S.M.A.R.T. monitors the rate at which errors occur and signals a predictive failure if the rate of degraded errors increases to an unacceptable level. To determine rate, error events are logged and compared to the number of total operations for a given attribute. The interval defines the number of operations over which to measure the rate. The counter that keeps track of the current number of operations is referred to as the Interval Counter.
16 Constellation ES.2 SAS Product Manual, Rev. G
S.M.A.R.T. measures error rates. All errors for each monitored attribute are recorded. A counter keeps track of the number of errors for the current interval. This counter is referred to as the Failure Counter.
Error rate is the number of errors per operation. The algorithm that S.M.A.R.T. uses to record rates of error is to set thresholds for the number of errors and their interval. If the number of errors exceeds the threshold before the interval expires, the error rate is considered to be unacceptable. If the number of errors does not exceed the threshold before the interval expires, the error rate is considered to be acceptable. In either case, the interval and failure counters are reset and the process starts over.
Predictive failures
S.M.A.R.T. signals predictive failures when the drive is performing unacceptably for a period of time. The firmware keeps a running count of the number of times the error rate for each attribute is unacceptable. To accomplish this, a counter is incremented each time the error rate is unacceptable and decremented (not to exceed zero) whenever the error rate is acceptable. If the counter continually increments such that it reaches the predictive threshold, a predictive failure is signaled. This counter is referred to as the Failure History
Counter. There is a separate Failure History Counter for each attribute.
6.2.5
Thermal monitor
Constellation ES.2 drives implement a temperature warning system which:
1. Signals the host if the temperature exceeds a value which would threaten the drive.
2. Signals the host if the temperature exceeds a user-specified value.
3. Saves a S.M.A.R.T. data frame on the drive which exceeds the threatening temperature value.
A temperature sensor monitors the drive temperature and issues a warning over the interface when the temperature exceeds a set threshold. The temperature is measured at power-up and then at ten-minute intervals after power-up.
The thermal monitor system generates a warning code of 01-0B01 when the temperature exceeds the specified limit in compliance with the SCSI standard. The drive temperature is reported in the FRU code field of mode sense data. You can use this information to determine if the warning is due to the temperature exceeding the drive threatening temperature or the user-specified temperature.
This feature is controlled by the Enable Warning (EWasc) bit, and the reporting mechanism is controlled by the
Method of Reporting Informational Exceptions field (MRIE) on the Informational Exceptions Control (IEC) mode page (1Ch).
The current algorithm implements two temperature trip points. The first trip point is set at 65°C which is the maximum temperature limit according to the drive specification. The second trip point is user-selectable using
be used to set this trip point. The default value for this drive is 65°C, however, you can set it to any value in the range of 0 to 65°C. If you specify a temperature greater than 65°C in this field, the temperature is rounded down to 65°C. A sense code is sent to the host to indicate the rounding of the parameter field.
Table 1: Temperature Log Page (0Dh)
Parameter Code
0000h
0001h
Description
Primary Temperature
Reference Temperature
Constellation ES.2 SAS Product Manual, Rev. G 17
6.2.6
Drive Self Test (DST)
Drive Self Test (DST) is a technology designed to recognize drive fault conditions that qualify the drive as a failed unit. DST validates the functionality of the drive at a system level.
There are two test coverage options implemented in DST:
1. Extended test
2. Short test
The most thorough option is the extended test that performs various tests on the drive and scans every logical block address (LBA) of the drive. The short test is time-restricted and limited in length—it does not scan the entire media surface, but does some fundamental tests and scans portions of the media.
If DST encounters an error during either of these tests, it reports a fault condition. If the drive fails the test, remove it from service and return it to Seagate for service.
6.2.6.1
DST failure definition
The drive will present a “diagnostic failed” condition through the self-tests results value of the diagnostic log page if a functional failure is encountered during DST. The channel and servo parameters are not modified to test the drive more stringently, and the number of retries are not reduced. All retries and recovery processes are enabled during the test. If data is recoverable, no failure condition will be reported regardless of the number of retries required to recover the data.
The following conditions are considered DST failure conditions:
• Seek error after retries are exhausted
• Track-follow error after retries are exhausted
• Read error after retries are exhausted
• Write error after retries are exhausted
Recovered errors will not be reported as diagnostic failures.
6.2.6.2
Implementation
This section provides all of the information necessary to implement the DST function on this drive.
6.2.6.2.1
State of the drive prior to testing
The drive must be in a ready state before issuing the Send Diagnostic command. There are multiple reasons why a drive may not be ready, some of which are valid conditions, and not errors. For example, a drive may be in process of doing a format, or another DST. It is the responsibility of the host application to determine the “not ready” cause.
While not technically part of DST, a Not Ready condition also qualifies the drive to be returned to Seagate as a failed drive.
A Drive Not Ready condition is reported by the drive under the following conditions:
• Motor will not spin
• Motor will not lock to speed
• Servo will not lock on track
• Drive cannot read configuration tables from the disk
In these conditions, the drive responds to a Test Unit Ready command with an 02/04/00 or 02/04/03 code.
6.2.6.2.2
Invoking DST
To invoke DST, submit the Send Diagnostic command with the appropriate Function Code (001b for the short test or 010b for the extended test) in bytes 1, bits 5, 6, and 7.
18 Constellation ES.2 SAS Product Manual, Rev. G
6.2.6.2.3
Short and extended tests
DST has two testing options:
1. short
2. extended
These testing options are described in the following two subsections.
Each test consists of three segments: an electrical test segment, a servo test segment, and a read/verify scan segment.
Short test (Function Code: 001b)
The purpose of the short test is to provide a time-limited test that tests as much of the drive as possible within
120 seconds. The short test does not scan the entire media surface, but does some fundamental tests and scans portions of the media. A complete read/verify scan is not performed and only factual failures will report a fault condition. This option provides a quick confidence test of the drive.
Extended test (Function Code: 010b)
The objective of the extended test option is to empirically test critical drive components. For example, the seek tests and on-track operations test the positioning mechanism. The read operation tests the read head element and the media surface. The write element is tested through read/write/read operations. The integrity of the media is checked through a read/verify scan of the media. Motor functionality is tested by default as a part of these tests.
The anticipated length of the Extended test is reported through the Control Mode page.
6.2.6.2.4
Log page entries
When the drive begins DST, it creates a new entry in the Self-test Results Log page. The new entry is created by inserting a new self-test parameter block at the beginning of the self-test results log parameter section of the log page. Existing data will be moved to make room for the new parameter block. The drive reports 20 parameter blocks in the log page. If there are more than 20 parameter blocks, the least recent parameter block will be deleted. The new parameter block will be initialized as follows:
1. The Function Code field is set to the same value as sent in the DST command
2. The Self-Test Results Value field is set to Fh
3. The drive will store the log page to non-volatile memory
After a self-test is complete or has been aborted, the drive updates the Self-Test Results Value field in its Self-
Test Results Log page in non-volatile memory. The host may use Log Sense to read the results from up to the last 20 self-tests performed by the drive. The self-test results value is a 4-bit field that reports the results of the test. If the field is set to zero, the drive passed with no errors detected by the DST. If the field is not set to zero, the test failed for the reason reported in the field.
The drive will report the failure condition and LBA (if applicable) in the Self-test Results Log parameter. The
Sense key, ASC, ASCQ, and FRU are used to report the failure condition.
6.2.6.2.5
Abort
There are several ways to abort a diagnostic. You can use a SCSI Bus Reset or a Bus Device Reset message to abort the diagnostic.
You can abort a DST executing in background mode by using the abort code in the DST Function Code field.
This will cause a 01 (self-test aborted by the application client) code to appear in the self-test results values log. All other abort mechanisms will be reported as a 02 (self-test routine was interrupted by a reset condition).
Constellation ES.2 SAS Product Manual, Rev. G 19
6.2.7
Product warranty
See “Seagate Technology support services” on page 1. for warranty contact information.
Shipping
When transporting or shipping a drive, use only a Seagate-approved container. Keep your original box.
Seagate approved containers are easily identified by the Seagate Approved Package label. Shipping a drive in a non-approved container voids the drive warranty.
Seagate repair centers may refuse receipt of components improperly packaged or obviously damaged in transit. Contact your authorized Seagate distributor to purchase additional boxes. Seagate recommends shipping by an air-ride carrier experienced in handling computer equipment.
Storage
The maximum recommended storage period for the drive in a non-operational environment is 90 days. Drives should be stored in the original unopened Seagate shipping packaging whenever possible. Once the drive is removed from the Seagate original packaging the recommended maximum period between drive operation cycles is 30 days. During any storage period the drive non-operational temperature, humidity, wet bulb, atmospheric conditions, shock, vibration, magnetic and electrical field specifications should be followed.
Product repair and return information
Seagate customer service centers are the only facilities authorized to service Seagate drives. Seagate does not sanction any third-party repair facilities. Any unauthorized repair or tampering with the factory seal voids the warranty.
20 Constellation ES.2 SAS Product Manual, Rev. G
7.0
Physical/electrical specifications
This section provides information relating to the physical and electrical characteristics of the drive.
7.1
PowerChoice
TM
power management
Drives using the load/unload architecture provide programmable power management to tailor systems for performance and greater energy efficiency.
The table below lists the supported PowerChoice modes. The further you go down in the table, the more power savings you get. For example, Idle_B mode results in greater power savings than Idle_A mode. Standby_Z mode results in the greatest power savings.
PowerChoice modes
Mode
Idle_A
Idle_B
Idle_C
Standby_Y
Standby_Z
Description
Reduced electronics
Heads unloaded. Disks spinning at full RPM
Heads unloaded. Disks spinning at reduced RPM
Heads unloaded. Disks spinning at reduced RPM.
Recovery requires the NOTIFY (Enable Spinup) command.
Heads unloaded. Motor stopped (disks not spinning)
Recovery requires the NOTIFY (Enable Spinup) command.
PowerChoice TM can be invoked using one of these two methods:
• Power Condition mode page method—Enable and initialize the idle condition timers and/or the standby condition timers. The timer values are based on the values set in the Power Condition mode page.
• START STOP UNIT command method—Use the START STOP UNIT command (OPERATION CODE 1Bh).
This allows the host to directly transition the drive to any supported PowerChoice mode.
If both the Power Condition mode page and START STOP UNIT command methods are used, the START
STOP UNIT command request takes precedence over the Power Condition mode page power control and may disable the idle condition and standby condition timers. The REQUEST SENSE command reports the current
PowerChoice state if active and also the method by which the drive entered the PowerChoice state.
When the drive receives a command, all power condition timers are suspended if they were enabled via the
Power Condition mode page. Once all outstanding commands are processed, the power condition timers are reinitialized to the values defined in the Power Condition mode page.
Constellation ES.2 SAS Product Manual, Rev. G 21
7.1.1
PowerChoice reporting methods
PowerChoice TM provides these reporting methods for tracking purposes:
Request Sense command reports
• Current power condition
• Method of entry
Note.
Processing the Request Sense command does not impact the drive’s power save state.
Mode Sense command reports (mode page 0x1A)
• Idle conditions enabled / disabled
• Idle condition timer values (100ms increments) (default, saved, current, changeable)
Power Condition Vital Product Data (VPD) Page (VPD page 0x8A)
• Supported power conditions
• Typical recovery time from power conditions (1ms increments)
Start/Stop Cycle Counter Log Page reports (log page 0x0E)
• Specified and accumulated Start/Stops and Load/Unload cycles
Power Condition Transitions Log Page reports (log page 0x1A, subpage 0x00)
• Accumulated transitions to Active, Idle_A, Idle_B, Idle_C, Standby_Y, Standby_Z
7.2
None.
AC power requirements
7.3
DC power requirements
The voltage and current requirements for a single drive are shown below. Values indicated apply at the drive connector.
The standard drive models and the SED drive models have identical hardware, however the security and encryption portion of the drive controller ASIC is enabled and functional in the SED models. This represents a small additional drain on the 5V supply of about 30mA and a commensurate increase of about 150mW in power consumption. There is no additional drain on the 12V supply.
22 Constellation ES.2 SAS Product Manual, Rev. G
Table 2: 3TB drive (Standard & SED model) DC power requirements
Voltage
Regulation
Avg idle current DCX
Advanced idle current
Idle_A
Idle_B
Idle_C/ Standby_Y
Standby_Z
Maximum starting current
(peak DC) DC
(peak AC) AC
Delayed motor start (max) DC
Peak operating current (random read):
Typical DCX
Maximum DC
Maximum (peak) DC
Peak operating current (random write)
Typical DCX
Maximum DC
Maximum (peak) DC
Peak operating current (sequential read)
Typical DCX
Maximum DC
Maximum (peak) DC
Peak operating current (sequential write)
Typical DCX
Maximum DC
Maximum (peak) DC
3 [5]
3 [5]
3
3
3
3
3
3
3
3
3
Notes
[5]
0.28
0.26
0.26
0.25
3.0Gb mode
(Amps) (Amps)
6.0Gb mode
(Amps) (Amps)
+5V
0.28
+5V
± 5% [2]
0.50
0.28
± 5% [2]
0.50
0.60
0.82
0.39
0.48
0.49
1.14
0.58
0.60
1.20
0.79
0.83
1.16
0.94
0.98
1.20
0.50
0.41
0.24
0.01
1.71
2.29
0.01
0.74
0.75
1.88
0.60
0.62
1.86
0.48
0.49
0.88
0.48
0.49
0.88
0.28
0.26
0.26
0.25
0.60
0.88
0.39
0.49
0.50
1.16
0.59
0.60
1.18
0.79
0.84
1.12
0.94
0.98
1.20
0.50
0.41
0.24
0.01
1.70
2.23
0.01
0.74
0.76
1.86
0.61
0.62
1.88
0.49
0.50
0.90
0.48
0.50
0.88
Constellation ES.2 SAS Product Manual, Rev. G 23
Table 3: 2TB drive (Standard & SED model) DC power requirements
Voltage
Regulation
Avg idle current DCX
Advanced idle current
Idle_A
Idle_B
Idle_C/ Standby_Y
Standby_Z
Maximum starting current
(peak DC) DC
(peak AC) AC
Delayed motor start (max) DC
Peak operating current (random read):
Typical DCX
Maximum DC
Maximum (peak) DC
Peak operating current (random write)
Typical DCX
Maximum DC
Maximum (peak) DC
Peak operating current (sequential read)
Typical DCX
Maximum DC
Maximum (peak) DC
Peak operating current (sequential write)
Typical DCX
Maximum DC
Maximum (peak) DC
3 [5]
3 [5]
3
3
3
3
3
3
3
3
3
Notes
[5]
0.28
0.26
0.26
0.27
3.0Gb mode
(Amps) (Amps)
6.0Gb mode
(Amps) (Amps)
+5V
0.46
+5V
± 5% [2]
0.39
0.46
± 5% [2]
0.39
0.60
0.80
0.37
0.50
0.51
1.07
0.57
0.58
1.09
0.78
0.80
1.11
0.94
0.97
1.20
0.42
0.34
0.20
0.01
1.72
2.33
0.01
0.69
0.71
1.76
0.54
0.56
1.66
0.40
0.41
0.86
0.40
0.41
0.82
0.28
0.26
0.26
0.27
0.59
0.89
0.39
0.50
0.52
1.13
0.58
0.59
1.11
0.78
0.81
1.14
0.95
0.98
1.24
0.42
0.34
0.20
0.01
1.71
2.29
0.01
0.70
0.72
1.74
0.54
0.56
1.82
0.40
0.41
0.80
0.40
0.41
0.78
24 Constellation ES.2 SAS Product Manual, Rev. G
[1] Measured with average reading DC ammeter.
[2] Instantaneous +12V current peaks will exceed these values.
[3] Power supply at nominal voltage. N (number of drives tested) = 6, 35 Degrees C ambient.
[4] For +12 V, a –10% tolerance is allowed during initial spindle start but must return to ± 5% before reaching
7200 RPM. The ± 5% must be maintained after the drive signifies that its power-up sequence has been completed and that the drive is able to accept selection by the host initiator.
[5] See +12V current profile in Figure 1.
[6] This condition occurs after OOB and Speed Negotiation completes but before the drive has received the
Notify Spinup primitive.
transient response.
[8] Operating condition is defined as random 8 block reads.
[9] During idle, the drive heads are relocated every 60 seconds to a random location within the band from three-quarters to maximum track.
General DC power requirement notes.
1. Minimum current loading for each supply voltage is not less than 1.7% of the maximum operating current shown.
2. The +5V and +12V supplies should employ separate ground returns.
3. Where power is provided to multiple drives from a common supply, careful consideration for individual drive power requirements should be noted. Where multiple units are powered on simultaneously, the peak starting current must be available to each device.
4. Parameters, other than spindle start, are measured after a 10-minute warm up.
5. No terminator power.
7.3.1
Conducted noise immunity
Noise is specified as a periodic and random distribution of frequencies covering a band from DC to 10 MHz.
Maximum allowed noise values given below are peak-to-peak measurements and apply at the drive power connector.
+5v = 250 mV pp from 100 Hz to 20 MHz.
+12v = 800 mV pp from 100 Hz to 8 KHz.
450 mV pp from 8 KHz to 20 KHz.
250 mV pp from 20 KHz to 5 MHz.
7.3.2
Power sequencing
The drive does not require power sequencing. The drive protects against inadvertent writing during power-up and down.
Constellation ES.2 SAS Product Manual, Rev. G 25
7.3.3
Current profiles
The 3TB +12V (top) and +5V (bottom) current profiles for the Constellation ES.2 drives are shown below.
Figure 1. 3TB model current profiles
26 Constellation ES.2 SAS Product Manual, Rev. G
The 2TB +12V (top) and +5V (bottom) current profiles for the Constellation ES.2 drives are shown below.
Figure 2. 2TB model current profiles
Note: All times and currents are typical. See Table 2 for maximum current requirements.
Constellation ES.2 SAS Product Manual, Rev. G 27
7.4
Power dissipation
3TB models in 3Gb operation
Please refer to Table 2 for power dissipation numbers.
To obtain operating power for typical random read operations, refer to the following I/O rate curve (see Figure
volt current, +12 volt current, and total watts on the vertical axis. To calculate BTUs per hour, multiply watts by
3.4123.
Figure 3. 3TB models (3Gb) DC current and power vs. input/output operations per second
Note.
For power details about SED vs. non-SED drive, please refer to section 7.8.
28 Constellation ES.2 SAS Product Manual, Rev. G
3TB models in 6Gb operation
Please refer to Table 2 for power dissipation numbers.
volt current, +12 volt current, and total watts on the vertical axis. To calculate BTUs per hour, multiply watts by
3.4123.
Figure 4. 3TB models (6Gb) DC current and power vs. input/output operations per second
Constellation ES.2 SAS Product Manual, Rev. G 29
2TB models in 3Gb operation
Please refer to Table 2 for power dissipation numbers.
volt current, +12 volt current, and total watts on the vertical axis. To calculate BTUs per hour, multiply watts by
3.4123.
Figure 5. 2TB models (3Gb) DC current and power vs. input/output operations per second
30 Constellation ES.2 SAS Product Manual, Rev. G
2TB models in 6Gb operation
Please refer to Table 2 for power dissipation numbers.
volt current, +12 volt current, and total watts on the vertical axis. To calculate BTUs per hour, multiply watts by
3.4123.
Figure 6. 2TB models (6Gb) DC current and power vs. input/output operations per second
Constellation ES.2 SAS Product Manual, Rev. G 31
7.5
Environmental limits
Temperature and humidity values experienced by the drive must be such that condensation does not occur on any drive part. Altitude and atmospheric pressure specifications are referenced to a standard day at 58.7°F
(14.8°C). Maximum wet bulb temperature is 82°F (28°C).
7.5.1
Temperature a. Operating
The drive meets the operating specifications over a 41°F to 140°F (5°C to 60°C) drive case temperature range with a maximum temperature gradient of 36°F (20°C) per hour.
The maximum allowable drive case temperature is 60°C. See Figure 7 for HDA case temperature
measurement location.
The MTBF specification for the drive assumes the operating environment is designed to maintain nominal case temperature. The rated MTBF is based upon a sustained case temperature of 104°F (40°C).
Occasional excursions in operating temperature between the rated MTBF temperature and the maximum drive operating case temperature may occur without impact to the rated MTBF temperature. However, continual or sustained operation at case temperatures beyond the rated MTBF temperature will degrade the drive MTBF and reduce product reliability.
confirm that the required cooling is provided for the electronics and HDA, place the drive in its final mechanical configuration, and perform random write/read operations. After the temperatures stabilize, measure the case temperature of the drive. b. Non-operating
–40° to 158°F (–40° to 70°C) package ambient with a maximum gradient of 36°F (20°C) per hour. This specification assumes that the drive is packaged in the shipping container designed by Seagate for use with drive.
HDA Temp.
Check Point
Figure 7. Location of the HDA temperature check point
Note.
Image is for reference only, may not represent actual drive.
7.5.2
Relative humidity
The values below assume that no condensation on the drive occurs.
a. Operating
5% to 95% non-condensing relative humidity with a maximum gradient of 20% per hour.
b. Non-operating
5% to 95% non-condensing relative humidity.
32 Constellation ES.2 SAS Product Manual, Rev. G
7.5.3
Effective altitude (sea level) a. Operating
–1000 to +10,000 feet (–304.8 to +3,048 meters) b. Non-operating
–1000 to +40,000 feet (–304.8 to +12,192 meters)
7.5.4
Shock and vibration
Shock and vibration limits specified in this document are measured directly on the drive chassis. If the drive is installed in an enclosure to which the stated shock and/or vibration criteria is applied, resonances may occur internally to the enclosure resulting in drive movement in excess of the stated limits. If this situation is apparent, it may be necessary to modify the enclosure to minimize drive movement.
The limits of shock and vibration defined within this document are specified with the drive mounted by any of
the four methods shown in Figure 8, and in accordance with the restrictions of Section 11.3.
7.5.4.1
Shock a. Operating—normal
The drive, as installed for normal operation, shall operate error free while subjected to intermittent shock not exceeding 70 Gs (read) and 40 Gs (write) at a maximum duration of 2ms (half sinewave). Shock may be applied in the X, Y, or Z axis. Shock is not to be repeated more than once every 2 seconds.
b. Operating—abnormal
Equipment, as installed for normal operation, does not incur physical damage while subjected to intermittent shock not exceeding 40 Gs at a maximum duration of 11ms (half sinewave). Shock occurring at abnormal levels may promote degraded operational performance during the abnormal shock period.
Specified operational performance will continue when normal operating shock levels resume. Shock may be applied in the X, Y, or Z axis. Shock is not to be repeated more than once every 2 seconds.
c. Non-operating
The limits of non-operating shock shall apply to all conditions of handling and transportation. This includes both isolated drives and integrated drives.
The drive subjected to nonrepetitive shock not exceeding 80 Gs at a maximum duration of 11ms (half sinewave) shall not exhibit device damage or performance degradation. Shock may be applied in the X, Y, or Z axis.
The drive subjected to nonrepetitive shock not exceeding 300 Gs at a maximum duration of 2ms (half sinewave) does not exhibit device damage or performance degradation. Shock may be applied in the X, Y, or Z axis.
The drive subjected to nonrepetitive shock not exceeding 200 Gs at a maximum duration of 0.5ms (half sinewave) does not exhibit device damage or performance degradation. Shock may be applied in the X, Y, or Z axis.
d. Packaged
Disk drives shipped as loose load (not palletized) general freight will be packaged to withstand drops from heights as defined in the table below. For additional details refer to Seagate specifications 30190-001
(under 100 lbs/45 kg) or 30191-001 (over 100 lbs/45 Kg).
Constellation ES.2 SAS Product Manual, Rev. G 33
Package size
<600 cu in (<9,800 cu cm)
600-1800 cu in (9,800-19,700 cu cm)
>1800 cu in (>19,700 cu cm)
>600 cu in (>9,800 cu cm)
Packaged/product weight
Any
0-20 lb (0 to 9.1 kg)
0-20 lb (0 to 9.1 kg)
20-40 lb (9.1 to 18.1 kg)
Drop height
60 in (1524 mm)
48 in (1219 mm)
42 in (1067 mm)
36 in (914 mm)
Drives packaged in single or multipacks with a gross weight of 20 pounds (8.95 kg) or less by Seagate for general freight shipment shall withstand a drop test from 48 in (1070 mm) against a concrete floor or equivalent.
Z
Y
X
Z
X
Y
Figure 8. Recommended mounting
Note.
Image is for reference only, may not represent actual drive.
34 Constellation ES.2 SAS Product Manual, Rev. G
7.5.4.2
Vibration a. Operating—normal
The drive as installed for normal operation, shall comply with the complete specified performance while subjected to continuous vibration not exceeding
5 - 22 Hz
22 - 350 Hz
350 - 500 Hz
0.25 Gs, limited displacement
0.5 Gs
0.25 Gs
Vibration may be applied in the X, Y, or Z axis.
b. Operating—abnormal
Equipment as installed for normal operation shall not incur physical damage while subjected to periodic vibration not exceeding:
15 minutes of duration at major resonant frequency
Vibration occurring at these levels may degrade operational performance during the abnormal vibration period. Specified operational performance will continue when normal operating vibration levels are resumed. This assumes system recovery routines are available.
Operating abnormal translational random flat profile
5-500 Hz @ 0.75 G (X, Y, or Z axis) c. Non-operating
The limits of non-operating vibration shall apply to all conditions of handling and transportation. This includes both isolated drives and integrated drives.
The drive shall not incur physical damage or degraded performance as a result of continuous vibration not exceeding
5 - 22 Hz
22 - 350 Hz
2 Gs (0 to peak, linear, swept sine, 0.5 octave/min)
5 Gs (0 to peak, linear, swept sine, 0.5 octave/min)
350 - 500 Hz 2 Gs (0 to peak, linear, swept sine, 0.5 octave/min)
Vibration may be applied in the X, Y, or Z axis.
7.5.5
Acoustics
Sound power during idle mode shall be 2.8 bels typical when measured to ISO 7779 specification. Sound power while operating shall be 3.0 bels typical when measured to ISO 7779 specification.
There will not be any discrete tones more than 10 dB above the masking noise on typical drives when measured according to Seagate specification 30553-001. There will not be any tones more than 24 dB above the masking noise on any drive.
7.5.6
Air cleanliness
The drive is designed to operate in a typical office environment with minimal environmental control.
7.5.7
Corrosive environment
Seagate electronic drive components pass accelerated corrosion testing equivalent to 10 years exposure to light industrial environments containing sulfurous gases, chlorine and nitric oxide, classes G and H per ASTM
B845. However, this accelerated testing cannot duplicate every potential application environment.
Users should use caution exposing any electronic components to uncontrolled chemical pollutants and corrosive chemicals as electronic drive component reliability can be affected by the installation environment.
The silver, copper, nickel and gold films used in Seagate products are especially sensitive to the presence of sulfide, chloride, and nitrate contaminants. Sulfur is found to be the most damaging. In addition, electronic
Constellation ES.2 SAS Product Manual, Rev. G 35
components should never be exposed to condensing water on the surface of the printed circuit board assembly
(PCBA) or exposed to an ambient relative humidity greater than 95%. Materials used in cabinet fabrication, such as vulcanized rubber, that can outgas corrosive compounds should be minimized or eliminated. The useful life of any electronic equipment may be extended by replacing materials near circuitry with sulfide-free alternatives.
7.5.8
Electromagnetic susceptibility
36 Constellation ES.2 SAS Product Manual, Rev. G
7.6
Mechanical specifications
3TB models
2TB models
Weight:
Weight:
1.499 lb
1.444 lb
680 g
655 g
Note.
These dimensions conform to the Small Form Factor Standard documented in SFF-8301 and
SFF-8323, found at www.sffcommittee.org
. in mm in mm
Breather
Hole in mm
Figure 9. Mounting configuration dimensions
Constellation ES.2 SAS Product Manual, Rev. G 37
8.0
About FIPS
The Federal Information Processing Standard (FIPS) Publication 140-2 is a U.S. Government Computer
Security Standard used to accredit cryptographic modules. It is titled 'Security Requirements for Cryptographic
Modules (FIPS PUB 140-2)' and is issued by the National Institute of Standards and Technology (NIST).
Purpose
This standard specifies the security requirements that will be satisfied by a cryptographic module utilized within a security system protecting sensitive but unclassified information. The standard provides four increasing, qualitative levels of security: Level 1, Level 2, Level 3 and Level 4. These levels are intended to cover the wide range of potential applications and environments in which cryptographic modules may be employed.
Validation Program
Products that claim conformance to this standard are validated by the Cryptographic Module Validation Program (CMVP) which is a joint effort between National Institute of Standards and Technology (NIST) and the
Communications Security Establishment (CSE) of the Government of Canada. Products validated as conforming to FIPS 140-2 are accepted by the Federal agencies of both countries for the protection of sensitive information (United States) or Designated Information (Canada).
In the CMVP, vendors of cryptographic modules use independent, accredited testing laborites to have their modules tested. National Voluntary Laboratory Accreditation Program (NVLAP) accredited laboratories perform cryptographic module compliance/conformance testing.
Seagate Enterprise SED
The SEDs referenced in this Product Manual have been validated by CMVP and have been thoroughly tested by a NVLAP accredited lab to satisfy FIPS 140-2 Level 2 requirements. In order to operate in FIPS Approved
Mode of Operation, these SEDs require security initialization. For more information, refer to 'Security Rules' section in the 'Security Policy' document uploaded on the NIST website. To reference the product certification visit - http://csrc.nist.gov/groups/STM/cmvp/documents/140-1/1401vend.htm
, and search for “Seagate”.
Security Level 2
Security Level 2 enhances the physical security mechanisms of a Security Level 1 cryptographic module by adding the requirement for tamper-evidence, which includes the use of tamper-evident coatings or seals on removable covers of the module. Tamper-evident coatings or seals are placed on a cryptographic module so that the coating or seal must be broken to attain physical access to the critical security
parameters (CSP) within the module. Tamper-evident seals (example shown in Figure 10, page 39) are
placed on covers to protect against unauthorized physical access. In addition Security Level 2 requires, at a minimum, role-based authentication in which a cryptographic module authenticates the authorization of an operator to assume a specific role and perform a corresponding set of services.
38 Constellation ES.2 SAS Product Manual, Rev. G
Figure 10. Example of FIPS tamper evidence labels.
Note.
Image is for reference only, may not represent actual drive.
Constellation ES.2 SAS Product Manual, Rev. G 39
9.0
About self-encrypting drives
Self-encrypting drives (SEDs) offer encryption and security services for the protection of stored data, commonly known as “protection of data at rest.” These drives are compliant with the Trusted Computing Group
(TCG) Enterprise Storage Specifications as detailed in Section 3.2.
The Trusted Computing Group (TCG) is an organization sponsored and operated by companies in the computer, storage and digital communications industry. Seagate’s SED models comply with the standards published by the TCG.
To use the security features in the drive, the host must be capable of constructing and issuing the following two
SCSI commands:
• Security Protocol Out
• Security Protocol In
These commands are used to convey the TCG protocol to and from the drive in their command payloads.
9.1
Data encryption
Encrypting drives use one inline encryption engine for each port, employing AES-256 data encryption in Cipher
Block Chaining (CBC) mode to encrypt all data prior to being written on the media and to decrypt all data as it is read from the media. The encryption engines are always in operation and cannot be disabled.
The 32-byte Data Encryption Key (DEK) is a random number which is generated by the drive, never leaves the drive, and is inaccessible to the host system. The DEK is itself encrypted when it is stored on the media and when it is in volatile temporary storage (DRAM) external to the encryption engine. A unique data encryption
key is used for each of the drive's possible16 data bands (see Section 9.5).
9.2
Controlled access
The drive has two security providers (SPs) called the "Admin SP" and the "Locking SP." These act as gatekeepers to the drive security services. Security-related commands will not be accepted unless they also supply the correct credentials to prove the requester is authorized to perform the command.
9.2.1
Admin SP
Access to the Admin SP is available using the SID (Secure ID) password or the MSID (Manufacturers Secure
ID) password.
9.2.2
Locking SP
The Locking SP controls read/write access to the media and the cryptographic erase feature. Access to the
Locking SP is available using the BandMasterX or EraseMaster passwords. Since the drive owner can define up to 16 data bands on the drive, each data band has its own password called BandMasterX where X is the number of the data band (0 through 15).
40 Constellation ES.2 SAS Product Manual, Rev. G
9.2.3
Default password
When the drive is shipped from the factory, all passwords are set to the value of MSID. This 32-byte random value is printed on the drive label and it can only be read by the host electronically over the interface. After receipt of the drive, it is the responsibility of the owner to use the default MSID password as the authority to change all other passwords to unique owner-specified values.
9.3
Random number generator (RNG)
The drive has a 32-byte hardware RNG that it is uses to derive encryption keys or, if requested to do so, to provide random numbers to the host for system use, including using these numbers as Authentication Keys
(passwords) for the drive’s Admin and Locking SPs.
9.4
Drive locking
access controls for the individual bands.
The variable "LockOnReset" should be set to "PowerCycle" to ensure that the data bands will be locked if power is lost. In addition "ReadLockEnabled" and "WriteLockEnabled" must be set to true in the locking table in order for the bands "LockOnReset" setting of "PowerCycle" to actually lock access to the band when a
"PowerCycle" event occurs. This scenario occurs if the drive is removed from its cabinet. The drive will not honor any data read or write requests until the bands have been unlocked. This prevents the user data from being accessed without the appropriate credentials when the drive has been removed from its cabinet and installed in another system.
When the drive is shipped from the factory, the firmware download port is unlocked.
9.5
Data bands
When shipped from the factory, the drive is configured with a single data band called Band 0 (also known as the Global Data Band) which comprises LBA 0 through LBA max. The host may allocate Band1 by specifying a start LBA and an LBA range. The real estate for this band is taken from the Global Band. An additional 14 Data
Bands may be defined in a similar way (Band2 through Band15) but before these bands can be allocated LBA space, they must first be individually enabled using the EraseMaster password.
Data bands cannot overlap but they can be sequential with one band ending at LBA (x) and the next beginning at LBA (x+1).
Each data band has its own drive-generated encryption key and its own user-supplied password. The host may
4K LBA boundaries.
9.6
Cryptographic erase
A significant feature of SEDs is the ability to perform a cryptographic erase. This involves the host telling the drive to change the data encryption key for a particular band. Once changed, the data is no longer recoverable since it was written with one key and will be read using a different key. Since the drive overwrites the old key with the new one, and keeps no history of key changes, the user data can never be recovered. This is tantamount to an instantaneous data erase and is very useful if the drive is to be scrapped or redispositioned.
Constellation ES.2 SAS Product Manual, Rev. G 41
9.7
Authenticated firmware download
In addition to providing a locking mechanism to prevent unwanted firmware download attempts, the drive also only accepts download files which have been cryptographically signed by the appropriate Seagate Design
Center.
Three conditions must be met before the drive will allow the download operation:
1. The download must be an SED file. A standard (base) drive (non-SED) file will be rejected.
2. The download file must be signed and authenticated.
3. As with a non-SED drive, the download file must pass the acceptance criteria for the drive. For example it must be applicable to the correct drive model, and have compatible revision and customer status.
9.8
Power requirements
The standard drive models and the SED drive models have identical hardware, however the security and encryption portion of the drive controller ASIC is enabled and functional in the SED models. This represents a small additional drain on the 5V supply of about 30mA and a commensurate increase of about 150mW in
requirements on the standard (non-SED) drive models.
9.9
Supported commands
The SED models support the following two commands in addition to the commands supported by the standard
(non-SED) models as listed in Table 7:
• Security Protocol Out (B5h)
• Security Protocol In (A2h)
9.10
Sanitize - CRYPTOGRAPHIC ERASE
This command cryptographically erases all user data on the drive by destroying the current data encryption key and replacing it with a new data encryption key randomly generated by the drive. Sanitize CRYPTOGRAPHIC
ERASE is a SCSI CDB Op code 48h and selecting the service action code 3 (CRYPTOGRAPHIC ERASE)
9.11
RevertSP
SED models will support the RevertSP feature which erases all data in all bands on the device and returns the contents of all SPs (Security Providers) on the device to their original factory state. In order to execute the
RevertSP method the unique PSID (Physical Secure ID) printed on the drive label must be provided. PSID is not electronically accessible and can only be manually read from the drive label or scanned in via the 2D barcode.
42 Constellation ES.2 SAS Product Manual, Rev. G
10.0
Defect and error management
Seagate continues to use innovative technologies to manage defects and errors. These technologies are designed to increase data integrity, perform drive self-maintenance, and validate proper drive operation.
SCSI defect and error management involves drive internal defect/error management and SAS system error considerations (errors in communications between the initiator and the drive). In addition, Seagate provides the following technologies used to increase data integrity and drive reliability:
• Background Media Scan (see Section 10.4)
• Media Pre-Scan (see Section 10.5)
• Deferred Auto-Reallocation (see Section 10.6)
• Idle Read After Write (see Section 10.7)
The read error rates and specified storage capacities are not dependent on host (initiator) defect management routines.
10.1
Drive internal defects/errors
During the initial drive format operation at the factory, media defects are identified, tagged as being unusable, and their locations recorded on the drive primary defects list (referred to as the “P’ list and also as the ETF defect list). At factory format time, these known defects are also reallocated, that is, reassigned to a new place on the medium and the location listed in the defects reallocation table. The “P” list is not altered after factory formatting. Locations of defects found and reallocated during error recovery procedures after drive shipment are listed in the “G” list (defects growth list). The “P” and “G” lists may be referenced by the initiator using the
Read Defect Data command.
Details of the SCSI commands supported by the drive are described in the SAS Interface Manual. Also, more information on the drive Error Recovery philosophy is presented in the SAS Interface Manual.
10.2
Drive error recovery procedures
When an error occurs during drive operation, the drive, if programmed to do so, performs error recovery procedures to attempt to recover the data. The error recovery procedures used depend on the options previously set in the Error Recovery Parameters mode page. Error recovery and defect management may involve using several SCSI commands described in the SAS Interface Manual. The drive implements selectable error recovery time limits required in video applications.
The error recovery scheme supported by the drive provides a way to control the total error recovery time for the entire command in addition to controlling the recovery level for a single LBA. The total amount of time spent in error recovery for a command can be limited using the Recovery Time Limit bytes in the Error Recovery mode page. The total amount of time spent in error recovery for a single LBA can be limited using the Read Retry
Count or Write Retry Count bytes in the Error Recovery mode page.
The drive firmware error recovery algorithms consist of 12 levels for read recoveries and five levels for write.
Each level may consist of multiple steps, where a step is defined as a recovery function involving a single reread or re-write attempt. The maximum level used by the drive in LBA recovery is determined by the read and write retry counts.
Constellation ES.2 SAS Product Manual, Rev. G 43
Table 4 equates the read and write retry count with the maximum possible recovery time for read and write recovery of individual LBAs. The times given do not include time taken to perform reallocations. Reallocations are performed when the ARRE bit (for reads) or AWRE bit (for writes) is one, the RC bit is zero, and the recovery time limit for the command has not yet been met. Time needed to perform reallocation is not counted against the recovery time limit.
When the RC bit is one, reallocations are disabled even if the ARRE or AWRE bits are one. The drive will still perform data recovery actions within the limits defined by the Read Retry Count, Write Retry Count, and
Recovery Time Limit parameters. However, the drive does not report any unrecovered errors.
Table 4: Read and write retry count maximum recovery times
Maximum recovery time per
LBA (cumulative, msec)
1
5
10
15
20 (default)
124.32
621.62
1243.23
1864.85
2486.47
0
1
2
3
4
5 (default)
Maximum recovery time per
LBA (cumulative, msec)
23.94
35.91
55.86
67.83
119.79
147.72
* For read retry count, every tick ~ 5% of total error recovery. Valid range setting is 1-20.
e.g. 1 ~ 5%
5 ~ 25%
20 ~ 100%
Setting these retry counts to a value below the default setting could result in degradation of the unrecovered error rate. For example, suppose the read/write recovery page has the RC bit = 0 and if the read retry count is set to 5, this means ~ 25% of error recovery will be executed which consumes 621.62 ms (please refer to the table above). If the limit is reached and a LBA has not yet been recovered (i.e. requires retries beyond 621.62 ms), the command will end with Check Condition status report and unrecoverable read error will be reported.
10.3
SAS system errors
Information on the reporting of operational errors or faults across the interface is given in the SAS Interface
Manual . The SSP Response returns information to the host about numerous kinds of errors or faults. The
Receive Diagnostic Results reports the results of diagnostic operations performed by the drive.
Status returned by the drive to the initiator is described in the SAS Interface Manual. Status reporting plays a role in systems error management and its use in that respect is described in sections where the various commands are discussed.
10.4
Background Media Scan
Background Media Scan (BMS) is a self-initiated media scan. BMS is defined in the T10 document SPC-4 available from the T10 committee. BMS performs sequential reads across the entire pack of the media while the drive is idle. In RAID arrays, BMS allows hot spare drives to be scanned for defects prior to being put into service by the host system. On regular duty drives, if the host system makes use of the BMS Log Page, it can avoid placing data in suspect locations on the media. Unreadable and recovered error sites will be logged or reallocated per ARRE/AWRE settings.
44 Constellation ES.2 SAS Product Manual, Rev. G
With BMS, the host system can consume less power and system overhead by only checking BMS status and results rather than tying up the bus and consuming power in the process of host-initiated media scanning activity.
Since the background scan functions are only done during idle periods, BMS causes a negligible impact to system performance. The first BMS scan for a newly manufactured drive is performed as quickly as possible to verify the media and protect data by setting the “Start time after idle” to 5ms, all subsequent scans begin after
500ms of idle time. Other features that normally use idle time to function will function normally because BMS functions for bursts of 800ms and then suspends activity for 100ms to allow other background functions to operate.
BMS interrupts immediately to service host commands from the interface bus while performing reads. BMS will complete any BMS-initiated error recovery prior to returning to service host-initiated commands. Overhead associated with a return to host-servicing activity from BMS only impacts the first command that interrupted
BMS, this results in a typical delay of about 1 ms.
10.5
Media Pre-Scan
Media Pre-Scan is a feature that allows the drive to repair media errors that would otherwise have been found by the host system during critical data accesses early in the drive’s life. The default setting for Media Pre-Scan is enabled on standard products. Media Pre-Scan checks each write command to determine if the destination
LBAs have been scanned by BMS. If the LBAs have been verified, the drive proceeds with the normal write command. If the LBAs have not been verified by BMS, Pre-Scan will convert the write to a write verify to certify that the data was properly written to the disk.
Note.
During Pre-Scan write verify commands, write performance may decrease by 50% until Pre-Scan completes. Write performance testing should be performed after Pre-Scan is complete. This may be checked by reading the BMS status.
To expedite the scan of the full pack and subsequently exit from the Pre-Scan period, BMS will begin scanning immediately when the drive goes to idle during the Pre-Scan period. In the event that the drive is in a high transaction traffic environment and is unable to complete a BMS scan within 24 power on hours BMS will disable Pre-Scan to restore full performance to the system.
10.6
Deferred Auto-Reallocation
Deferred Auto-Reallocation (DAR) simplifies reallocation algorithms at the system level by allowing the drive to reallocate unreadable locations on a subsequent write command. Sites are marked for DAR during read operations performed by the drive. When a write command is received for an LBA marked for DAR, the autoreallocation process is invoked and attempts to rewrite the data to the original location. If a verification of this rewrite fails, the sector is re-mapped to a spare location.
This is in contrast to the system having to use the Reassign Command to reassign a location that was unreadable and then generate a write command to rewrite the data. DAR is most effective when AWRE and
ARRE are enabled—this is the default setting from the Seagate factory. With AWRE and ARRE disabled DAR is unable to reallocate the failing location and will report an error sense code indicating that a write command is being attempted to a previously failing location.
10.7
Idle Read After Write
Idle Read After Write (IRAW) utilizes idle time to verify the integrity of recently written data. During idle periods, no active system requests, the drive reads recently written data from the media and compares it to valid write command data resident in the drives data buffer. Any sectors that fail the comparison result in the invocation of a rewrite and auto-reallocation process. The process attempts to rewrite the data to the original location. If a verification of this rewrite fails, the sector is re-mapped to a spare location.
Constellation ES.2 SAS Product Manual, Rev. G 45
10.8
Protection Information (PI)
Protection Information is intended as a standardized approach to system level LRC traditionally provided by systems using 520 byte formatted LBAs. Drives formatted with PI information provide the same, common LBA count (i.e. same capacity point) as non-PI formatted drives. Sequential performance of a PI drive will be reduced by approximately 1.56% due to the extra overhead of PI being transferred from the media that is not calculated as part of the data transferred to the host. To determine the full transfer rate of a PI drive, transfers should be calculated by adding the 8 extra bytes of PI to the transferred LBA length, i.e. 512 + 8 = 520. PI formatted drives are physically formatted to 520 byte sectors that store 512 bytes of customer data with 8 bytes of
Protection Information appended to it. The advantage of PI is that the Protection Information bits can be managed at the HBA and HBA driver level. Allowing a system that typically does not support 520 LBA formats to integrate this level of protection.
Protection Information is valid with any supported LBA size. 512 LBA size is used here as common example.
10.8.1
Levels of PI
There are 4 types of Protection Information.
Type 0 - Describes a drive that is not formatted with PI information bytes. This allows for legacy support in non-
PI systems.
Type 1 - Provides support of PI protection using 10 and 16 byte commands. The RDPROTECT and WRTPRO-
TECT bits allow for checking control through the CDB. Eight bytes of Protection Information are transmitted at
LBA boundaries across the interface if RDPROTECT and WRTPROTECT bits are nonzero values. Type 1 does not allow the use of 32 byte commands.
Type 2 - Provides checking control and additional expected fields within the 32 byte CDBs. Eight bytes of Protection Information are transmitted at LBA boundaries across the interface if RDPROTECT and WRTPRO-
TECT bits are nonzero values. Type 2 does allow the use of 10 and 16 byte commands with zero values in the
RDPROTECT and WRTPROTECT fields. The drive will generate 8 bytes (e.g.0xFFFF) 8 bytes of Protection
Information to be stored on the media, but the 8 bytes will not be transferred to the host during a read command.
Type 3 - Seagate products do not support Type 3.
10.8.2
Setting and determining the current Type Level
A drive is initialized to a type of PI by using the format command on a PI capable drive. Once a drive is formatted to a PI Type, it may be queried by a Read Capacity (16) command to report the PI type which it is currently formatted to. PI Types cannot coexist on a single drive. A drive can only be formatted to a single PI Type. It can be changed at anytime to a new Type but requires a low level format which destroys all existing data on the drive. No other vehicle for changing the PI type is provided by the T10 SBC3 specification.
Type 1 PI format CDB command: 04 90 00 00 00 00, Write Buffer: 00 A0 00 00
Type 2 PI format CDB command: 04 D0 00 00 00 00, Write Buffer: 00 A0 00 00
10.8.3
Identifying a Protection Information drive
The Standard Inquiry provides a bit to indicate if PI is support by the drive. Vital Product Descriptor (VPD) page
0x86 provides bits to indicate the PI Types supported and which PI fields the drive supports checking.
Note.
For further details with respect to PI, please refer to SCSI Block Commands - 3 (SBC-3) Draft Standard documentation.
46 Constellation ES.2 SAS Product Manual, Rev. G
11.0
Installation
Constellation ES.2 disk drive installation is a plug-and-play process. There are no jumpers, switches, or terminators on the drive.
SAS drives are designed to be used in a host system that provides a SAS-compatible backplane with bays designed to accommodate the drive. In such systems, the host system typically provides a carrier or tray into which you need to mount the drive. Mount the drive to the carrier or tray provided by the host system using four
M3 x 0.5 metric screws. When tightening the screws, use a maximum torque of 4.5 in-lb +/- 0.45 in-lb. Do not over-tighten or force the screws. You can mount the drive in any orientation.
Note.
SAS drives are designed to be attached to the host system without I/O or power cables. If you intend the use the drive in a non-backplane host system, connecting the drive using high-quality cables is acceptable as long as the I/O cable length does not exceed 4 meters (13.1 feet).
Slide the carrier or tray into the appropriate bay in your host system using the instructions provided by the host system. This connects the drive directly to your system’s SAS connector. The SAS connector is normally
located on a SAS backpanel. See Section 12.4.1 for additional information about these connectors.
Power is supplied through the SAS connector.
The drive is shipped from the factory low-level formatted in 512-byte logical blocks. You need to reformat the drive only if you want to select a different logical block size.
Figure 11. Physical interface
Note.
Image is for reference only, may not represent actual drive.
11.1
Drive orientation
The drive may be mounted in any orientation. All drive performance characterizations, however, have been done with the drive in horizontal (discs level) and vertical (drive on its side) orientations, which are the two preferred mounting orientations.
Constellation ES.2 SAS Product Manual, Rev. G 47
11.2
Cooling
Cabinet cooling must be designed by the customer so that the ambient temperature immediately surrounding
the drive will not exceed temperature conditions specified in Section 7.5.1, "Temperature."
The rack, cabinet, or drawer environment for the drive must provide heat removal from the electronics and head and disk assembly (HDA). You should confirm that adequate heat removal is provided using the
temperature measurement guidelines described in Section 7.5.1.
in which case the drive should be oriented, or air flow directed, so that the least amount of air flow resistance is created while providing air flow to the electronics and HDA. Also, the shortest possible path between the air inlet and exit should be chosen to minimize the travel length of air heated by the drive and other heat sources within the rack, cabinet, or drawer environment.
patterns are created by one or more fans, either forcing or drawing air as shown in the illustrations.
Conduction, convection, or other forced air-flow patterns are acceptable as long as the temperature
measurement guidelines of Section 7.5.1 are met.
Above unit
Note. Air flows in the direction shown (back to front)
or in reverse direction (front to back)
Under unit
Above unit
Under unit
Note. Air flows in the direction shown or
in reverse direction (side to side)
Figure 12. Air flow
Note.
Image is for reference only, may not represent actual drive.
48 Constellation ES.2 SAS Product Manual, Rev. G
11.3
Drive mounting
Mount the drive using the bottom or side mounting holes. If you mount the drive using the bottom holes, ensure that you do not physically distort the drive by attempting to mount it on a stiff, non-flat surface.
The allowable mounting surface stiffness is 80 lb/in (14.0 N/mm). The following equation and paragraph define the allowable mounting surface stiffness:
K x X = F < 15lb = 67N where K is the mounting surface stiffness (units in lb/in or N/mm) and X is the out-of-plane surface distortion
(units in inches or millimeters). The out-of-plane distortion (X) is determined by defining a plane with three of the four mounting points fixed and evaluating the out-of-plane deflection of the fourth mounting point when a known force (F) is applied to the fourth point.
Note.
Do not cover breather hole on top cover.
Breather Hole
Do Not
Cover
Breather hole location - top cover
11.4
Grounding
Signal ground (PCBA) and HDA ground are connected together in the drive and cannot be separated by the user. The equipment in which the drive is mounted is connected directly to the HDA and PCBA with no electrically isolating shock mounts. If it is desired for the system chassis to not be connected to the HDA/PCBA ground, the systems integrator or user must provide a nonconductive (electrically isolating) method of mounting the drive in the host equipment.
Increased radiated emissions may result if you do not provide the maximum surface area ground connection between system ground and drive ground. This is the system designer’s and integrator’s responsibility.
Constellation ES.2 SAS Product Manual, Rev. G 49
12.0
Interface requirements
This section partially describes the interface requirements as implemented on Constellation ES.2 drives.
Additional information is provided in the SAS Interface Manual (part number 100293071).
12.1
SAS features
This section lists the SAS-specific features supported by Constellation ES.2 drives.
12.1.1
task management functions
Table 5 lists the SAS task management functions supported.
Table 5: SAS task management functions supported
Task name
Abort Task
Clear ACA
Clear task set
Abort task set
Logical Unit Reset
Query Task
Supported
Yes
Yes
Yes
Yes
Yes
Yes
12.1.2
task management responses
Table 6 lists the SAS response codes returned for task management functions supported.
Table 6: Task management response codes
Function name
Function complete
Invalid frame
Function not supported
Function failed
Function succeeded
Invalid logical unit
Response code
00
02
04
05
08
09
50 Constellation ES.2 SAS Product Manual, Rev. G
12.2
Dual port support
Constellation ES.2 SAS drives have two independent ports. These ports may be connected in the same or different SCSI domains. Each drive port has a unique SAS address.
The two ports have the capability of independent port clocking (e.g. both ports can run at 6Gb/s or the first port can run at 6Gb/s while the second port runs at 3Gb/s. The supported link rates are 1.5, 3.0, or 6.0 Gb/s.
Subject to buffer availability, the Constellation ES.2 drives support:
• Concurrent port transfers—The drive supports receiving COMMAND, TASK management transfers on both ports at the same time.
• Full duplex—The drive supports sending XFER_RDY, DATA and RESPONSE transfers while receiving frames on both ports.
Constellation ES.2 SAS Product Manual, Rev. G 51
12.3
SCSI commands supported
Table 7 lists the SCSI commands supported by Constellation ES.2 drives.
Table 7: Supported commands
Command name
Change Definition
Compare
Copy
Copy and Verify
Format Unit [1] [5]
DCRT bit supported
DPRY bit supported
DSP bit supported
IMMED bit supported
IP bit supported
SI (Security Initialize) bit supported
STPF bit supported
VS (vendor specific)
Inquiry
Date Code page (C1h)
Device Behavior page (C3h)
Firmware Numbers page (C0h)
Implemented Operating Def page (81h)
Jumper Settings page (C2h)
Supported Vital Product Data page (00h)
Unit Serial Number page (80h)
Lock-unlock cache
Log Select
PCR bit
DU bit
DS bit
TSD bit
ETC bit
TMC bit
LP bit
Protocol-specific Log Page for SAS (18h)
Log Sense
Application Client Log page (0Fh)
Buffer Over-run/Under-run page (01h)
Cache Statistics page (37h)
Factory Log page (3Eh)
Information Exceptions Log page (2Fh)
Command code
40h
39h
18h
3Ah
04h
12h
36h
4Ch
4Dh
Supported
Y
Y
N
N
Y
N
N
Y
Y
Y
N
N
N
Y
Y
Y
N
Y
Y
Y
Y
Y
Y
N
Y
N
Y
Y
Y
N
Y
Y
Y
N
N
N
N
52 Constellation ES.2 SAS Product Manual, Rev. G
Table 7: Supported commands
Command name
Last n Deferred Errors or Asynchronous Events page (0Bh)
Last n Error Events page (07h)
Non-medium Error page (06h)
Pages Supported list (00h)
Read Error Counter page (03h)
Read Reverse Error Counter page (04h)
Self-test Results page (10h)
Start-stop Cycle Counter page (0Eh)
Temperature page (0Dh)
Verify Error Counter page (05h)
Write error counter page (02h)
Mode Select (same pages as Mode Sense 1Ah)
Mode Select (10) (same pages as Mode Sense 1Ah)
Mode Sense
Caching Parameters page (08h)
Control Mode page (0Ah)
Disconnect/Reconnect (02h)
Error Recovery page (01h)
Format page (03h)
Information Exceptions Control page (1Ch)
Notch and Partition Page (0Ch)
Protocol-Specific Port page (19h)
Power Condition page (1Ah)
Rigid disk Drive Geometry page (04h)
Unit Attention page (00h)
Verify Error Recovery page (07h)
Xor Control page (10h)
Mode Sense (10) (same pages as Mode Sense 1Ah)
Persistent Reserve In
Persistent Reserve Out
Prefetch
Read (6)
Read (10)
DPO bit supported
FUA bit supported
Read (12)
Read (16)
Read (32)
Read Buffer (modes 0, 2, 3, Ah and Bh supported)
Command code
15h
55h
1Ah
5Ah
5Eh
5Fh
34h
08h
28h
A8h
88h
7Fh/0009h
3Ch
Supported
N
Y
Y
Y
N
Y
Y
Y
Y
Y
N
Y
Y
Y
Y
Y
Y
Y
Y
Y [2]
Y
Y
Y
Y [2]
Y
Y
Y
N
Y
Y
N
N
Y
N
Y
Y
Y
N
Y (non-SED drives only)
Constellation ES.2 SAS Product Manual, Rev. G 53
Table 7: Supported commands
Command name
Read Capacity (10)
Read Capacity (16)
Read Defect Data (10)
Read Defect Data (12)
Read Long
Read Long (16)
Reassign Blocks
Receive Diagnostic Results
Supported Diagnostics pages (00h)
Translate page (40h)
Release
Release (10)
Report LUNs
Request Sense
Actual Retry Count bytes
Extended Sense
Field Pointer bytes
Reserve
3rd Party Reserve
Extent Reservation
Reserve (10)
3rd Party Reserve
Extent Reservation
Rezero Unit
Sanitize (CRYPTOGRAPHIC ERASE)
Search Data Equal
Search Data High
Search Data Low
Security Protocol In
Security Protocol Out
Seek (6)
Seek (10)
Send Diagnostics
Supported Diagnostics pages (00h)
Translate page (40h)
Set Limits
Start Unit/Stop Unit (spindle ceases rotating)
Synchronize Cache
Synchronize Cache (16)
54
01h
48h
31h
30h
32h
A2h
B5h
0Bh
2Bh
1Dh
Command code
25h
9Eh/10h
37h
B7h
3Eh
9Eh/11h
07h
1Ch
17h
57h
A0h
03h
16h
56h
33h
1Bh
35h
91h
Supported
Y
Y
Y
Y
N
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y (non-SED drives only)
Y
N
Y
Y
Y
Y
N
Y
Y
N
N
Y (SED drives only)
N
Y
Y
Y (SED models only)
Y (SED models only)
Constellation ES.2 SAS Product Manual, Rev. G
Table 7: Supported commands
Command name
Test Unit Ready
Verify (10)
BYTCHK bit
Verify (12)
Verify (16)
Verify (32)
Write (6)
Write (10)
DPO bit
FUA bit
Write (12)
Write (16)
Write (32)
Write and Verify (10)
DPO bit
Write and Verify (12)
Write and Verify (16)
Write and Verify (32)
Write Buffer (modes 0, 2, supported)
Write Buffer
Firmware Download option (modes 5, 7, Ah and Bh) [3]
Firmware Download option (modes 4, 5, 7)
Write Long (10)
Write Long (16)
PBdata
LBdata
Write Same (32)
XDRead
XDWrite
XPWrite
Command code
00h
2Fh
AFh
AFh
7Fh/000Ah
0Ah
2Ah
AAh
8Ah
7Fh/000Bh
2Eh
AEh
8Eh
7Fh/000Ch
3Bh
3Bh
3Fh
9Fh/11h
41h
Supported
N
N
N
N
Y
N
N
Y
N
Y
Y
Y
Y
Y
Y
N
Y
N
Y
Y
Y
N
Y (non-SED drives only)
N
Y
Y
N
Y
Y
Y (non-SED drives only)
Y (SED drives only)
93h
7Fh/000Dh
52h
50h
51h
[1] Constellation ES.2 drives can format to 512, 520 or 528 bytes per logical block.
[2] Warning. Power loss during flash programming can result in firmware corruption. This usually makes the drive inoperable.
[3] Reference Mode Sense command 1Ah for mode pages supported.
[4] Y = Yes. Command is supported.
N = No. Command is not supported.
A = Support is available on special request.
[5] Approximately 1.5 increase in time to complete this command for a SED drive versus a non-SED drive of the same capacity.
Constellation ES.2 SAS Product Manual, Rev. G 55
12.3.1
Inquiry data
SAS Interface Manual .
Table 8: Constellation ES.2 inquiry data
Bytes
0-15
16-31
32-47
48-63
64-79
80-95
96-111
112-127
128-143
Data (hex)
00 00 xx** 12
[53 54 33 33
R# R# R#
00 00 00
R#
00
8B
30
S#
00
00
30
S#
00
30
30
S#
00
02
36
S#
00
53
35
S#
00
45
30
S#
00
41
53
S#
00
00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00
00 43 6F 70 79 72 69 67 68 74 20
30* 30* 39* 20 53 65 61 67 61 74 65
72 69 67 68 74 73 20 72 65 73 65
47 41 54
53} 20 20
S# 00 00
00 00 00
45 20 Vendor ID
20 20 Product ID
00 00
00 00
00 00 00 00 00
00 00 00 00 00
28 63 29 20 32* *Copyright
20 41 6C 6C 20 notice
72 76 65 64 20
* Copyright year (changes with actual year).
** SCSI Revision support. See the appropriate SPC release documentation for definitions.
PP 10 = Inquiry data for an Inquiry command received on Port A.
30 = Inquiry data for an Inquiry command received on Port B.
R# Four ASCII digits representing the last four digits of the product firmware release number.
S# Eight ASCII digits representing the eight digits of the product serial number.
[ ] Bytes 16 through 26 reflect model of drive. The table above shows the hex values for Model ST33000650SS.
Refer to the values below for the values of bytes 16 through 26 of your particular model:
ST33000651SS
ST33000652SS
ST32000645SS
ST32000646SS
ST32000647SS
53 54 33 33 30 30 30 36 35 31 53 53
53 54 33 33 30 30 30 36 35 32 53 53
53 54 33 32 30 30 30 36 34 35 53 53
53 54 33 32 30 30 30 36 34 36 53 53
53 54 33 32 30 30 30 36 34 37 53 53
12.3.2
Mode Sense data
The Mode Sense command provides a way for the drive to report its operating parameters to the initiator. The drive maintains four sets of mode parameters:
1. Default values
Default values are hard-coded in the drive firmware stored in flash E-PROM (nonvolatile memory) on the drive’s PCB. These default values can be changed only by downloading a complete set of new firmware into the flash E-PROM. An initiator can request and receive from the drive a list of default values and use those in a Mode Select command to set up new current and saved values, where the values are changeable.
2. Saved values
Saved values are stored on the drive’s media using a Mode Select command. Only parameter values that are allowed to be changed can be changed by this method. Parameters in the saved values list that are not changeable by the Mode Select command get their values from default values storage.
56 Constellation ES.2 SAS Product Manual, Rev. G
When power is applied to the drive, it takes saved values from the media and stores them as current values in volatile memory. It is not possible to change the current values (or the saved values) with a Mode
Select command before the drive achieves operating speed and is “ready.” An attempt to do so results in a
“Check Condition” status.
On drives requiring unique saved values, the required unique saved values are stored into the saved values storage location on the media prior to shipping the drive. Some drives may have unique firmware with unique default values also.
On standard OEM drives, the saved values are taken from the default values list and stored into the saved values storage location on the media prior to shipping.
3. Current values
Current values are volatile values being used by the drive to control its operation. A Mode Select command can be used to change the values identified as changeable values. Originally, current values are installed from saved or default values after a power on reset, hard reset, or Bus Device Reset message.
4. Changeable values
Changeable values form a bit mask, stored in nonvolatile memory, that dictates which of the current values and saved values can be changed by a Mode Select command. A one (1) indicates the value can be
in the row entitled “CHG.” These are hex numbers representing the changeable values for Mode page 81.
Note in columns 5 and 6 (bytes 04 and 05), there is 00h which indicates that in bytes 04 and 05 none of the bits are changeable. Note also that bytes 06, 07, 09, 10, and 11 are not changeable, because those fields are all zeros. In byte 02, hex value FF equates to the binary pattern 11111111. If there is a zero in any bit position in the field, it means that bit is not changeable. Since all of the bits in byte 02 are ones, all of these bits are changeable.
The changeable values list can only be changed by downloading new firmware into the flash E-PROM.
Note.
Because there are often several different versions of drive control firmware in the total population of drives in the field, the Mode Sense values given in the following tables may not exactly match those of some drives.
The following tables list the values of the data bytes returned by the drive in response to the Mode Sense command pages for SCSI implementation (see the SAS Interface Manual ).
DEF = Default value. Standard OEM drives are shipped configured this way.
CHG = Changeable bits; indicates if default value is changeable.
Constellation ES.2 SAS Product Manual, Rev. G 57
Table 9: Mode Sense data changeable and default values for 3TB drives
MODE DATA HEADER:
01 9a 00 10 01 00 00 10
BLOCK DESCRIPTOR:
00 00 00 01 5d 50 a3 b0 00 00 00 00 00 00 02 00
MODE PAGES:
DEF 81 0a c0 14 ff 00 00 00 05 00 ff ff
CHG 81 0a ff ff 00 00 00 00 ff 00 ff ff
DEF 82 0e 00 00 00 00 00 00 00 00 01 3a 00 00 00 00
CHG 82 0e 00 00 00 00 00 00 00 00 ff ff 00 00 00 00
DEF 83 16 bb d0 00 00 00 00 03 80 04 C4 02 00 00 01 00 DC 00 32 40 00 00 00
CHG 83 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
DEF 84 16 04 52 50 0a 00 00 00 00 00 00 00 00 00 00 00 00 00 00 1c 20 00 00
CHG 84 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
DEF 87 0a 00 14 ff 00 00 00 00 00 ff ff
CHG 87 0a 0f ff 00 00 00 00 00 00 ff ff
DEF 88 12 14 00 ff ff 00 00 ff ff ff ff 80 20 00 00 00 00 00 00
CHG 88 12 a5 00 00 00 ff ff ff ff 00 00 20 00 00 00 00 00 00 00
DEF 8a 0a 06 00 00 80 00 00 00 00 6b d0
CHG 8a 0a 07 f6 00 00 00 00 00 00 00 00
DEF 18 06 06 00 00 00 00 00
CHG 18 06 00 00 00 00 00 00
DEF 99 0e 46 00 07 d0 00 00 00 00 00 00 00 00 00 00
CHG 99 0e 50 00 ff ff ff ff ff ff 00 00 00 00 00 00
DEF 9a 26 00 06 00 00 05 14 00 00 8c a0 00 00 17 70 00 00 46 50 00 00 46 50 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00
CHG 9a 26 01 0f ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00
DEF 9c 0a 10 00 00 00 00 00 00 00 00 01
CHG 9c 0a 9d 0f ff ff ff ff ff ff ff ff
DEF dc 01 00 0c 01 01 00 48 00 18 01 f4 00 00 00 00
CHG dc 01 00 0c 00 01 ff ff ff ff ff ff ff ff 00 00
DEF 80 06 00 80 0f 00 00 00
CHG 80 06 b7 c0 0f 00 00 00
58 Constellation ES.2 SAS Product Manual, Rev. G
Table 10: Mode Sense data changeable and default values for 2TB drives
MODE DATA HEADER:
01 9a 00 10 01 00 00 10
BLOCK DESCRIPTOR:
00 00 00 01 5d 50 a3 b0 00 00 00 00 00 00 02 00
MODE PAGES:
DEF 81 0a c0 14 ff 00 00 00 05 00 ff ff
CHG 81 0a ff ff 00 00 00 00 ff 00 ff ff
DEF 82 0e 00 00 00 00 00 00 00 00 01 3a 00 00 00 00
CHG 82 0e 00 00 00 00 00 00 00 00 ff ff 00 00 00 00
DEF 83 16 bb d0 00 00 00 00 03 80 04 C4 02 00 00 01 00 DC 00 32 40 00 00 00
CHG 83 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
DEF 84 16 04 52 50 07 00 00 00 00 00 00 00 00 00 00 00 00 00 00 1c 20 00 00
CHG 84 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
DEF 87 0a 00 14 ff 00 00 00 00 00 ff ff
CHG 87 0a 0f ff 00 00 00 00 00 00 ff ff
DEF 88 12 14 00 ff ff 00 00 ff ff ff ff 80 20 00 00 00 00 00 00
CHG 88 12 a5 00 00 00 ff ff ff ff 00 00 20 00 00 00 00 00 00 00
DEF 8a 0a 02 00 00 80 00 00 00 00 7f ff
CHG 8a 0a 07 f6 00 00 00 00 00 00 00 00
DEF 18 06 06 00 00 00 00 00
CHG 18 06 00 00 00 00 00 00
DEF 99 0e 46 00 07 d0 00 00 00 00 00 00 00 00 00 00
CHG 99 0e 50 00 ff ff ff ff ff ff 00 00 00 00 00 00
DEF 9a 26 00 06 00 00 00 0a 00 00 8c a0 00 00 17 70 00 00 46 50 00 00 46 50 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00
CHG 9a 26 01 0f ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00
DEF 9c 0a 10 00 00 00 00 00 00 00 00 01
CHG 9c 0a 9d 0f ff ff ff ff ff ff ff ff
DEF dc 01 00 0c 01 01 00 48 00 18 01 f4 00 00 00 00
CHG dc 01 00 0c 00 01 ff ff ff ff ff ff ff ff 00 00
DEF 80 06 00 80 0f 00 00 00
CHG 80 06 b7 c0 0f 00 00 00
Constellation ES.2 SAS Product Manual, Rev. G 59
12.4
Miscellaneous operating features and conditions
supported. An “N” in the support column indicates the feature or condition is not supported.
Table 11: Miscellaneous features
Y
Y
Y
Y
N
Y
Supported
N
Y
N
N
N
Feature or condition
Automatic contingent allegiance
Asynchronous event notification
Synchronized (locked) spindle operation
Segmented caching
Zero latency read
Queue tagging (up to 64 queue tags supported)
Deferred error handling
Parameter rounding (controlled by Round bit in Mode Select page 0)
Reporting actual retry count in Extended Sense bytes 15, 16, and 17
Adaptive caching
SMP = 1 in Mode Select command needed to save RPL and rotational offset bytes
Table 12: Miscellaneous status
Supported
Y
Y
Y
Y
Y
Y
N
N
Y
Y
Status
Good
Check condition
Condition met/good
Busy
Intermediate/good
Intermediate/condition met/good
Reservation conflict
Task set full
ACA active
ACA active, faulted initiator
60 Constellation ES.2 SAS Product Manual, Rev. G
12.4.1
SAS physical interface
SAS connector.
Details of the physical, electrical, and logical characteristics are provided within this section. The operational aspects of Seagate’s SAS drives are provided in the SAS Interface Manual.
Figure 13. Physical interface
Constellation ES.2 SAS Product Manual, Rev. G 61
5.92
7.62
0.80 (6X)
4.65
0.30 0.05 (2X)
2.00 (3X)
B
C
5.08
42.73 REF.
41.13 0.15
0.20 B
0.45 0.03 (7X)
0.10 M E
0.52 0.08 x 45
A
1.10
4.00 0.08
0.15 D
0.30 0.05 (4X) B
A R0.30 0.08 (4X)
C
15.875
1.27 (14X)
33.43 0.05
5.08
15.875
1.27 (6X)
SEE Detail1
B
0.84 0.05 (22X)
0.15 B
4.90 0.08
0.35MIN
P15
P1
S7
S1
Figure 14. SAS device plug dimensions
62 Constellation ES.2 SAS Product Manual, Rev. G
S14
Detail A
6.10
S8
0.30 0.05 x 45 (5X)
2.25 0.05
4.85 0.05
0.10 B
E
0.40 0.05 X 45 (3X)
CORING ALLOWED
IN THIS AREA.
SEE Detail 2
4.40 0.15
A
R0.30 0.08
45
C
1.95 0.08
0.35 0.05
3.90 0.15
SECTION A - A
SECTION C - C
0.08 0.05
CONTACT SURFACE FLUSH
TO DATUM A 0.03
1.23 0.05
30
Detail 2
0.08 0.05
2.40 0.08
0.10 A
D
Figure 15. SAS device plug dimensions (detail)
65
SECTION B - B
1.90 0.08
Constellation ES.2 SAS Product Manual, Rev. G 63
12.4.2
Physical characteristics
This section defines physical interface connector.
12.4.3
Connector requirements
Contact your preferred connector manufacturer for mating part information. Part numbers for SAS connectors will be provided in a future revision of this publication when production parts are available from major connector manufacturers.
The SAS device connector is illustrated in Figures 14 and 15.
12.4.4
Electrical description
SAS drives use the device connector for:
• DC power
• SAS interface
• Activity LED
This connector is designed to either plug directly into a backpanel or accept cables.
12.4.5
Pin descriptions
This section provides a pin-out of the SAS device and a description of the functions provided by the pins.
Table 13: SAS pin descriptions
Signal type
S4
S5*
S6*
S7
Pin
S1
S2*
S3*
Signal name
Port A Ground
+Port A_in
-Port A_in
Port A Ground
-Port A_out
+Port A_out
Port A Ground
S8
S9*
Port B Ground
+Port B_in
S10* -Port B_in
S11 Port A Ground
S12* -Port B_out
S13* +Port B_out
S14 Port B Ground
Diff. input pair
Diff output pair
Diff. input pair
Diff output pair
P4
P5
P6
P7
Pin
P1*
P2*
P3
Signal name
NC (reserved 3.3Volts)
NC (reserved 3.3Volts)
NC (reserved 3.3Volts)
Ground
Ground
Ground
5 Volts charge
P8*
P9*
5 Volts
5 Volts
P10 Ground
P11* Ready LED
P12
P13
Ground
12 Volts charge
P14* 12 Volts
P15* 12 Volts
Signal type
Open collector out
* - Short pin to support hot plugging
NC - No connection in the drive.
64 Constellation ES.2 SAS Product Manual, Rev. G
12.4.6
SAS transmitters and receivers
coupling to eliminate ground shift noise.
TX
Transmitter
100
TY
Differential
Transfer Medium
.01
.01
RX
RY
Receiver
100
Figure 16. SAS transmitters and receivers
12.4.7
Power
The drive receives power (+5 volts and +12 volts) through the SAS device connector.
Three +12 volt pins provide power to the drive, 2 short and 1 long. The current return for the +12 volt power supply is through the common ground pins. The supply current and return current must be distributed as evenly as possible among the pins.
Three +5 volt pins provide power to the drive, 2 short and 1 long. The current return for the +5 volt power supply is through the common ground pins. The supply current and return current must be distributed as evenly as possible among the pins.
Current to the drive through the long power pins may be limited by the system to reduce inrush current to the drive during hot plugging.
12.5
Signal characteristics
for signal type and signal name information.
12.5.1
Ready LED Out
The Ready LED Out signal is driven by the drive as indicated in Table 14.
Table 14: Ready LED Out conditions
Normal command activity
Ready LED Meaning bit mode page 19h
Spun down and no activity
Spun down and activity (command executing)
Spun up and no activity
Spun up and activity (command executing)
Spinning up or down
Format in progress, each cylinder change
LED status
0 1
Off
On
On
Off
On
Off
Off On
Blinks steadily
(50% on and 50% off, 0.5 seconds on and off for 0.5 seconds)
Toggles on/off
Constellation ES.2 SAS Product Manual, Rev. G 65
The Ready LED Out signal is designed to pull down the cathode of an LED. The anode is attached to the proper +3.3 volt supply through an appropriate current limiting resistor. The LED and the current limiting
Table 15: LED drive signal
State
LED off, high
LED o n, low
Test condition
0 V VOH 3.6 V
I
OL
= 15 mA
Output voltage
-100 μA < I
OH
< 100 μA
0 V
OL
0.225 V
12.5.2
Differential signals
The drive SAS differential signals comply with the intra-enclosure (internal connector) requirements of the SAS standard.
Table 16 defines the general interface characteristics.
Table 16: General interface characteristics
Characteristic
Bit rate (nominal)
Unit interval (UI)(nominal)
Impedance (nominal, differential )
Transmitter transients, maximum
Receiver transients, maximum
Units
Mbaud ps ohm
V
V
1.5Gb/s
1,500
666.6
100
1.2
1.2
3.0Gb/s
3,000
333.3
100
1.2
1.2
6.0Gb/s
6,000
166.6
100
1.2
1.2
12.6
SAS-2 Specification Compliance
Seagate SAS-2 drives are entirely compatible with the latest SAS-2 Specification (T10/1760-D) Revision 16.
The most important characteristic of the SAS-2 drive at 6Gb/s is that the receiver is capable of adapting the equalizer to optimize the receive margins. The SAS-2 drive has two types of equalizers:
1. A Decision Feedback Equalizer (DFE) which utilizes the standard SAS-2 training pattern transmitted during the SNW-3 training gap. The DFE circuit can derive an optimal equalization characteristic to compensate for many of the receive losses in the system.
2. A Feed Forward Equalizer (FFE) optimized to provide balanced receive margins over a range of channels bounded by the best and worst case channels as defined by the relevant ANSI standard.
12.7
Additional information
Please contact your Seagate representative for SAS electrical details, if required.
For more information about the Phy, Link, Transport, and Applications layers of the SAS interface, refer to the
Seagate SAS Interface Manual, part number 100293071.
For more information about the SCSI commands used by Seagate SAS drives, refer to the Seagate SCSI
Commands Reference Manual, part number 100293068.
66 Constellation ES.2 SAS Product Manual, Rev. G
Index
Numerics
12 volt pins
5 volt pins
6 Gbps
A abort task set function
AC coupling
AC power requirements
ACA active status
ACA active, faulted initiator status
acoustics
active LED Out signal
actuator
assembly design
adaptive caching
Admin SP
AES-128 data encryption
air cleanliness
air flow
illustrated
air inlet
altitude
ambient
ambient temperature
ANSI documents
SCSI
Serial Attached SCSI
asynchronous event notification
audible noise
Australian C-Tick
auto write and read reallocation programmable
automatic contingent allegiance
average idle current
average rotational latency
B
Background Media Scan
backpanel
Band 0
BandMasterX
BMS
BSMI
buffer data
space
busy status
bytes per surface
bytes per track
Constellation ES.2 SAS Product Manual, Rev. G
C cache operation
cache segments
caching write data
Canadian Department of Communications
capacity unformatted
CBC
CE Marking
check condition status
China RoHS directive
Cipher Block Chaining
class B limit
clear ACA function
clear task set function
commands supported
condensation
condition met/good status
connector illustrated
requirements
continuous vibration
cooling
CRC error
Cryptographic erase
cryptographic erase
C-Tick
Current profiles
customer service
D
DAR
Data Bands
data bands
data block size modifing the
data buffer to/from disk media
Data encryption
Data Encryption Key
data heads read/write
data rate internal
data transfer rate
DC power
requirements
Decision Feedback Equalizer
decrypt
default MSID password
defect and error management
defects
Deferred Auto-Reallocation
deferred error handling
67
DEK
description
DFE
dimensions
disk rotation speed
drive
drive characteristics
Drive Locking
drive mounting
drive select
dual port support
E electrical description of connector
signal characteristics
specifications
electromagnetic compatibility
Electromagnetic Compatibility (EMC)
Electromagnetic Compatibility control Regulation
Electromagnetic compliance for the European Union
electromagnetic susceptibility
EMI requirements
encryption engine
encryption key
environment
environmental environmental control
EraseMaster
error limits
requirements
management
rates
errors
European Union
F
FCC rules and regulations
features
interface
Federal Information Processing Standard
feed forward equalizer
FFE
FIPS
firmware
corruption
firmware download port
flawed sector reallocation
Format command execution time
function complete, code 00
not supported, code 05
reject, code 04
G
Global Data Band
Good status
gradient
ground shift noise
grounding
H
HDA
head and disk assembly (HDA)
head and disk assembly. See HDA
heads read/write data
heat removal
heat source
host equipment
hot plugging the drive
humidity
humidity limits
I
Identifying a PI drive
Idle Read After Write
Idle1
Idle2
Idle3
inquiry data
installation
guide
interface commands supported
error rate
errors
illustrated
physical
requirements
interleave minimum
intermediate/condition met/good status
intermediate/good status
internal data rate
internal defects/errors
internal drive characteristics
IRAW
J jumpers
K
KCC
Korean Communications Commission
68 Constellation ES.2 SAS Product Manual, Rev. G
Korean KCC
L latency average rotational
Locking SP
LockOnReset
logical block address
logical block reallocation scheme
logical block size
logical segments
M maintenance
Manufacturers Secure ID
maximum delayed motor start
maximum start current
mean time between failure. See MTBF
media description
Media Pre-Scan
minimum sector interleave
miscellaneous feature support
Adaptive caching
Asynchronous event notification
Automatic contingent allegiance
Deferred error handling
Parameter rounding
Queue tagging
Reporting actual retry count
Segmented caching
SMP = 1 in Mode Select command
Synchronized (locked) spindle operation
Zero latency read
miscellaneous status support
ACA active
ACA active, faulted initiator
Busy
Check condition
Condition met/good
Good
Intermediate/condition met/good
Intermediate/good
Reservation conflict
Task set full
miscorrected media data
Mode sense data, table
mounting
holes
orientations
mounting configuration
mounting configuration dimensions
MSID
MTBF
N noise audible
noise immunity
non-operating
temperature
non-operating vibration
O office environment
operating
option selection
options
out-of-plane distortion
P package size
packaged
parameter rounding
password
passwords
PCBA
peak bits per inch
peak operating current
peak-to-peak measurements
performance characteristics detailed
general
performance degradation
performance highlights
physical damage
physical interface
physical specifications
PI level - Type 0
PI level - Type I
PI level - Type II
PI level - Type III
PI Levels
pin descriptions
power
dissipation
requirements, AC
requirements, DC
sequencing
Power Condition mode page
power distribution
power management
PowerChoice
PowerChoice reports
PowerCycle
prefetch/multi-segmented cache control
preventive maintenance
protection information
protection of data at rest
Constellation ES.2 SAS Product Manual, Rev. G 69
Q queue tagging
R radio interference regulations
Random number generator
RCD bit
read error rates
read/write data heads
ReadLockEnabled
receivers
recommended mounting
Recoverable Errors
recovered media data
reference documents
relative humidity
reliability
specifications
reliability and service
repair and return information
reporting actual retry count
reservation conflict status
resonance
return information
RevertSP
RNG
RoHS
rotation speed
S safety
Sanitize
SAS interface
physical interface
task management functions
SAS documents
SAS Interface Manual
SAS-2 specification compliance
SCSI interface commands supported
Secure ID
Security Protocol In
Security Protocol Out
security providers
seek error defined
rate
seek performance characteristics
seek time average typical
full stroke typical
single track typical
70 segmented caching
self-encrypting drives
Self-Monitoring Analysis and Reporting Technology
Serial Attached SCSI (SAS) Interface Manual
shielding
shipping
shipping container
shock
and vibration
shock mount
SID
signal characteristics
single-unit shipping pack kit
SMART
SMP = 1 in Mode Select command
SNW-3 training gap
standards
Standby1
Standby2
START STOP UNIT command
start/stop time
support services
surface stiffness allowable for non-flat surface
switches
synchronized spindle operation
system chassis
T
Taiwanese BSMI
task management functions
Abort task set
Clear ACA
Clear task set
terminate task
task management response codes
Function complete 00
Function not supported 05
Function reject 04
task set full status
TCG
technical support services
temperature
limits
non-operating
regulation
terminate task function
terminators
tracks per inch
tracks per surface
transmitters
Constellation ES.2 SAS Product Manual, Rev. G
transporting the drive
Trusted Computing Group
Type 1 PI format
Type 2 PI format
U unformatted
Unrecoverable Errors
unrecovered media data
V vibration
W warranty
WriteLockEnabled
Z zero latency read
Constellation ES.2 SAS Product Manual, Rev. G 71
72 Constellation ES.2 SAS Product Manual, Rev. G
Seagate Technology LLC
AMERICAS Seagate Technology LLC 10200 South De Anza Boulevard, Cupertino, California 95014, United States, 408-658-1000
ASIA/PACIFIC Seagate Singapore International Headquarters Pte. Ltd. 7000 Ang Mo Kio Avenue 5, Singapore 569877, 65-6485-3888
EUROPE, MIDDLE EAST AND AFRICA Seagate Technology SAS 16-18 rue du Dôme, 92100 Boulogne-Billancourt, France, 33 1-4186 10 00
Publication Number: 100628615, Rev. G
February 2012
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 9 Seagate Technology support services
- 10 Scope
- 11 Applicable standards and reference documentation
- 11 Standards
- 11 Electromagnetic compatibility
- 12 Electromagnetic compliance
- 13 European Union Restriction of Hazardous Substances (RoHS)
- 13 China Restriction of Hazardous Substances (RoHS) Directive
- 14 Reference documents
- 15 General description
- 16 Standard features
- 16 Media description
- 16 Performance
- 17 Reliability
- 17 Formatted capacities
- 17 Programmable drive capacity
- 17 Factory-installed options
- 18 Performance characteristics
- 18 Internal drive characteristics
- 18 Seek performance characteristics
- 18 Access time
- 19 Format command execution time for 512-byte sectors (minutes)
- 19 General performance characteristics
- 19 Start/stop time
- 20 Prefetch/multi-segmented cache control
- 20 Cache operation
- 21 Caching write data
- 21 Prefetch operation
- 22 Reliability specifications
- 22 Error rates
- 22 Recoverable Errors
- 22 Unrecoverable Errors
- 23 Seek errors
- 23 Interface errors
- 23 Reliability and service
- 23 Annualized Failure Rate (AFR) and Mean Time Between Failure (MTBF)
- 23 Preventive maintenance
- 23 Hot plugging the drive
- 24 S.M.A.R.T
- 25 Thermal monitor
- 26 Drive Self Test (DST)
- 28 Product warranty
- 29 Physical/electrical specifications
- 29 power management
- 30 PowerChoice reporting methods
- 30 AC power requirements
- 30 DC power requirements
- 33 Conducted noise immunity
- 33 Power sequencing
- 34 Current profiles
- 36 Power dissipation
- 40 Environmental limits
- 40 Temperature
- 40 Relative humidity
- 41 Effective altitude (sea level)
- 41 Shock and vibration
- 43 Acoustics
- 43 Air cleanliness
- 43 Corrosive environment
- 44 Electromagnetic susceptibility
- 45 Mechanical specifications
- 46 About FIPS
- 48 About self-encrypting drives
- 48 Data encryption
- 48 Controlled access
- 48 Admin SP
- 48 Locking SP
- 49 Default password
- 49 Random number generator (RNG)
- 49 Drive locking
- 49 Data bands
- 49 Cryptographic erase
- 50 Authenticated firmware download
- 50 Power requirements
- 50 Supported commands
- 50 Sanitize - CRYPTOGRAPHIC ERASE
- 50 RevertSP
- 51 Defect and error management
- 51 Drive internal defects/errors
- 51 Drive error recovery procedures
- 52 SAS system errors
- 52 Background Media Scan
- 53 Media Pre-Scan
- 53 Deferred Auto-Reallocation
- 53 Idle Read After Write
- 54 Protection Information (PI)
- 54 Levels of PI
- 54 Setting and determining the current Type Level
- 54 Identifying a Protection Information drive
- 55 Installation
- 55 Drive orientation
- 56 Cooling
- 57 Drive mounting
- 57 Grounding
- 58 Interface requirements
- 58 SAS features
- 58 task management functions
- 58 task management responses
- 59 Dual port support
- 60 SCSI commands supported
- 64 Inquiry data
- 64 Mode Sense data
- 68 Miscellaneous operating features and conditions
- 69 SAS physical interface
- 72 Physical characteristics
- 72 Connector requirements
- 72 Electrical description
- 72 Pin descriptions
- 73 SAS transmitters and receivers
- 73 Power
- 73 Signal characteristics
- 73 Ready LED Out
- 74 Differential signals
- 74 SAS-2 Specification Compliance
- 74 Additional information