SmartOnline 30kVA On-Line Double-Conversion
UPS, 3 Phase input / output with oversize battery set
MODEL NUMBER: SU30K3/3XR5
Highlights
30,000 VA (30kVA) EXTENDED
RUNTIME tower UPS with internal batteries
Saves valuable space and simplifies runtime scalability
3-phase hardwire input and output (120/208VAC). Wide input voltage correction range (96 -
144V AC / 166 - 250V AC)
IGBT technology and zero transfer time, on-line, double-conversion operation
3 communication ports, SNMP card slot and EPO jack
Package Includes
SU30K3/3XR5 UPS System
Description
Tripp Lite's SU30K3/3XR5 30kVA SmartOnline 3-Phase Intelligent, True On-Line Extended Runtime UPS
System has been redesigned to save valuable space and simplify runtime scalability. Power and battery components are combined into a single, small-footprint module (the smallest in its class). A robust internal battery runtime capability can be easily extended by installing additional optional internal battery packs through the convenient front panel access door. The SU30K3/3XR5 features a large internal battery compartment that
(power and battery components in one module)
PowerAlert Software and cabling
Warranty information
Instruction manual contains more internal batteries than the equivalent standard-run model (SU30K3/3) and more space to add additional optional internal battery packs to extend runtime. The SU30K3/3XR5 provides mission critical equipment with the highest level of power protection available. Large capacity 30,000VA/24,000 watt UPS continually converts incoming AC power into filtered DC power, and then resynthesizes it back into AC power with a pure sine wave. Perfectly regulated, continuous sine wave output with zero transfer time offers compatibility with all equipment types. IGBT inverter technology produces output power with <3%
THD (total harmonic distortion), allowing connected equipment to perform at its peak. A 3:1 crest factor safely supports a variety of equipment, even those with wildly-fluctuating power demands. Extremely efficient operation saves money by lowering electricity consumption. Hardwire input and output connections support a variety of permanent or PDU style power connections. SU30K3/3XR5 features 120/208V AC, 3-phase, 4-wire (plus ground), wye input and output. It also features a wide input voltage correction range: 96 -144/166-250V AC. Frequency is 50 or 60 Hz (auto-selectable). SU30K3/3XR5 includes internal power and battery components in a single small-footprint tower module. Battery support can be extended with additional internal battery packs. A manual bypass switch as well as an automatic bypass function ensure 100% availability of connected equipment by safely passing through AC power when the UPS requires maintenance. Three built-in communication ports (RS-232, contact closure and AS-400) work with included PowerAlert Software to simultaneously provide shutdown commands and reporting on multiple servers without the need for costly accessories. An accessory slot accepts an optional internal SNMP card
(model # SNMPWEBCARD) for remote shutdowns, reboots and more. A Battery Start Switch allows cold restart of UPS during a prolonged blackout to utilize its batteries for periodic system access or data retrieval. An Emergency Power Off button turns UPS output OFF and disables Bypass output. Built-in
Emergency Power Off (EPO) interface supports remote emergency shutdown in large facilities. Front panel combination LCD/LED display alerts users to a
Features
Large internal battery compartment contains more internal batteries than the equivalent standard-run model (SU30K3/3) and more space to add additional optional internal battery packs to extend runtime.Saves valuable space: power and battery components combined into a single small-footprint module
1 / 5
module
Simplifies runtime scalability: convenient front panel battery access for expandable runtime with additional internal battery packs
True on-line, double conversion UPS with IGBT technology provides pure, sine wave AC output at all times
Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time
Removes harmonic distortion, electrical impulses, frequency variations and other hard-to-solve power problems
30,000VA/24,000 watt power capacity with 3-phase, hardwire 120/208V AC input/output connections
Features a wide input voltage correction range: 96 - 144/166 - 250V AC
61 minutes runtime at half load (11,300 watts) based on adding 3 SURBC2030 battery packs and 11 minutes runtime at full load (24,000 watts)
3:1 crest factor safely supports a variety of equipment, even those with wildly-fluctuating power demands
Extend runtime by installing optional internal battery packs (model # SURBC2030) through the front panel access door. SU30K3/3XR5 includes 5 internal battery packs and accepts 3 additional internal battery packs. A standalone battery module compartment with a 4 battery pack capacity and daisy-chain capability (model # SUBF2030) is available to further extend runtime.
3 communication ports (RS-232, contact closure and AS-400)
Slot for optional SNMP card (model # SNMPWEBCARD)
Manual bypass switch as well as an automatic bypass function ensures 100% availability of connected equipment by safely passing through AC power when the UPS system requires maintenance
Battery Start Switch allows cold restart of UPS during a prolonged blackout to utilize its batteries for periodic system access or data retrieval
Emergency Power Off button turns UPS output OFF and disables Bypass output
PowerAlert Universal UPS Power Management Software and 6 ft. communication cable included
Built-in Emergency Power Off (EPO) interface supports remote emergency shutdown in large facilities
Combination LED/LCD display
Start-up service program is recommended to enhance the reliability of the installation
Specifications
OUTPUT
Output Volt Amp Capacity (VA)
Output kVA capacity (kVA)
Output Watt Capacity (watts)
Output kW capacity
Output power factor
Crest Factor
Nominal Output Voltage(s)
Supported
30000
30
24000
24
0.8
3:1
120/208V; 3-Phase Wye
Frequency compatibility 50 / 60 Hz
Output voltage regulation (line mode) +/- 2%
Output voltage regulation (Battery mode)
+/- 2%
Built-in UPS output receptacles
Output AC waveform (AC mode)
Hardwire
Sine wave
2 / 5
Output AC waveform (battery mode) Pure Sine wave
INPUT
Rated input current (at maximum load)
90A (per phase, online)
Nominal Input Voltage(s) Supported 120/208V AC (3ph wye)
Nominal input voltage description 3-Phase Wye, 4 wire (L1, L2, L3, N, G)
UPS input connection type
Phase
Hardwire
3-Phase
BATTERY
Full load runtime (minutes)
Half load runtime (minutes)
Expandable battery runtime
External battery pack compatibility
Expandable runtime description
DC system voltage (VDC)
Battery recharge rate (included batteries)
Replacement battery cartridge
(internal UPS battery replacement)
Battery Access
Battery replacement description
11 min. (24kw)
25 min. (12kw)
Supports extended runtime with optional external battery packs
SURBC2030 ; SUBF2030 (holds 4 SURBC2030 )
Includes a battery housing with space for 3 internal SURBC2030 battery packs for extended runtime. Additional runtime capacity is available by adding SUBF2030 and additional SURBC2030 batteries - see runtime chart for specific recommendations
240
2 - 4 hours from 10% to 90%
SURBC2030
Front panel internal battery access door
Hot-swappable, replaceable batteries
VOLTAGE REGULATION
Voltage regulation description
Overvoltage correction
Undervoltage correction
Online, double-conversion power conditioning
Maintains continuous operation without using battery power during overvoltages to 144 / 250 (3-Phase, 4-Wire, wye), reducing output within 2% of nominal
Maintains continuous operation without using battery power during brownout / undervoltage conditions to 96 / 166
(3-Phase, 4-Wire, wye)
LEDS ALARMS & SWITCHES
LED Indicators
Front panel LCD display
Alarms
Alarm cancel operation
7 LED DISPLAY: AC input, bypass input, AC-DC charger, DC-AC inverter, AC output, bypass operation and battery operation
SELECTABLE LCD DISPLAY: indicates a wide range of UPS operational and fault/warning conditions including operational mode, alarm/shutdown conditions, input/output voltage/frequency, battery voltage, load percentage and more (see manual)
Alarms warn against a variety of operational conditions: low-battery, overload, shutdown, bypass and more
Power-fail alarm can be silenced using alarm-cancel switch
3 / 5
Switches
"ON" button turns UPS's inverter ON. "OFF" button turns UPS's inverter OFF. "Select" Button browses through items displayed on LCD screen. "Enter" button selects items displayed on LCD screen. "Select" and "Enter" buttons used simultaneously mute UPS alarms. "Battery Start" Switch cold starts the inverter. "Emergency Power Off" button turns UPS output OFF and disables Bypass output. "Manual Bypass" switch bypasses the UPS's inverter during maintenance.
SURGE / NOISE SUPPRESSION
EMI / RFI AC noise suppression
AC suppression joule rating
AC suppression response time
Yes
2032
Instantaneous
PHYSICAL
Installation form factors supported with included accessories
Primary form factor
UPS / Power Module dimensions in primary form factor (height x width x depth / inches)
UPS / Power Module dimensions in primary form factor (height x width x depth / cm)
UPS / Power Module weight (lbs)
UPS / Power Module weight (kg)
UPS Shipping dimensions (height x width x depth / inches)
UPS Shipping dimensions (height x width x depth / cm)
Shipping weight (lbs)
Shipping weight (kg)
Cooling method
UPS housing material
Tower
Tower
50.9 x 19.5 x 36.8
129.3 x 49.5 x 93.5
935
424.5
61.5 x 31 x 44.5
156.2 x 78.7 x 113
1152
523
Fans
Steel
ENVIRONMENTAL
Operating Temperature Range
Storage Temperature Range
Relative Humidity
AC mode BTU / hr. (full load)
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.
0 to 95%, non-condensing
11171
COMMUNICATIONS
Communications interface DB9 Serial; Contact closure; Slot for SNMP/Web interface
Network monitoring port description RS232, contact closure and AS400 monitoring ports are supported by 3 separate DB9 ports
PowerAlert software Included
4 / 5
Communications cable
LINE / BATTERY TRANSFER
Transfer time
Low voltage transfer to battery power (setpoint)
High voltage transfer to battery power (setpoint)
DB9 cabling included
No transfer time (0 ms.) in online, double-conversion mode
Maintains continuous operation during undervoltages as low as 96 / 166V AC (3-Phase, 4-Wire, wye). Below this point, output is maintained utilizing battery reserves.
Maintains continuous operation during overvoltages as high as 144 / 250V AC (3-Phase, 4-Wire, wye). Above this point, output is maintained utilizing battery reserves.
SPECIAL FEATURES
Cold Start (startup in battery mode during a power failure)
High availability UPS features
Cold-start operation supported
Automatic inverter bypass; Hot swappable batteries
CERTIFICATIONS
UPS Certifications Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)
WARRANTY
Product Warranty Period (U.S. &
Canada)
Product Warranty Period
(International)
Product Warranty Period (Mexico)
Product Warranty Period (Puerto
Rico)
1-year limited warranty
2-year limited warranty
1-year limited warranty
2-year limited warranty
© 2014 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement.
Specifications are subject to change without notice. Photos may differ slightly from final products.
5 / 5