EnerGenie EG-PMS surge protector User manual

Add to my manuals
50 Pages

advertisement

EnerGenie EG-PMS surge protector User manual | Manualzz

EG-PMS PROGRAMMABLE USB SURGE

PROTECTOR

USER MANUAL

HANDBUCH

HANDLEIDING

MANUEL DESCRIPTIF

РУКОВОДСТВО ПОЛЬЗОВАТЕЛЯ

КЕРІВНИЦТВО КОРИСТУВАЧА

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

PROGRAMMABLE SURGE PROTECTOR

PROGRAMMIERBARE STECKDOSENLEISTE

PROGRAMMEERBARE STEKKERDOOS

PARASURTENSEUR PROGRAMMABLE

ПРОГРАММИРУЕМЫЙ СЕТЕВОЙ ФИЛЬТР

ПРОГРАМОВАНИЙ СЕТЕВОЙ ФІЛЬТР

All brands and logos are registered trademarks of their respective owners

2

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

Contents

1. Introduction 4

1.1. Features 4

1.2. Specifications 6

1.3. Hardware requirements 6

1.4. Package contents 7

2. Indicators and controls of EG-PMS 8

2.1. Side panel 9

2.2. Indicators 10

2.3. Audible signals 10

3. Installation

3.1. Getting started

11

11

3.2. Power Manager installation

4. Power Manager software

4.1. Managing EG-PMS

4.2. Setting up the hardware schedule

4.3. Setting up the software schedule

4.4. Setting up application events

23

27

5. Power Manager advanced features 34

5.1. Processing the alarms 35

5.2. Managing EG-PMS via your own software

6. Troubleshooting

13

13

13

18

36

45

All brands and logos are registered trademarks of their respective owners

3

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

1. Introduction

Congratulations with your purchase of this Energenie Power

Manager. Your EG-PMS is an advanced surge protector with power management features. Four sockets are individually manageable by the computer via USB interface.

The sockets can be switched on/off by a timer schedule, by user or different events. It is also possible to pre-program the unit event timer schedule (hardware schedule) and then disconnect EG-PMS from the managing computer. The device can be used as an advanced standbykiller.

1.1. Features

• The main rocker switch enables switching all the sockets on and off

• In addition to it every manageable socket can be switched on and off via the software control window

• The unit can be pre-programmed via hardware-based schedule. The hardware schedule will work even when the managing computer is switched off

All brands and logos are registered trademarks of their respective owners

4

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

• The unit will keep performing the programmed hardware time schedule even after EG-PMS is disconnected from the power for some time

• The manageable sockets can then be switched on and off by the schedule, simple typical applications could be: “switch my peripherals on every working day at 8:50 AM” etc.

• The manageable sockets can also be programmed with Power

Manager software to react whenever a certain event occurs

(Windows or other programs start-up/shutdown), simple typical applications could be: “switch my scanner on when I want to scan” or “switch my printer off whenever I exit Windows”

• Real time Voltage monitor provides information about the actual status of each manageable socket (on or off). This information can be further utilized in various ways (e.g. to check the proper execution of the switching commands)

• The unit can be assigned a network name as a shared LAN resource and can be afterwards accessed and managed from anywhere within the local area network or Internet (provided the managing computer is switched on)

All brands and logos are registered trademarks of their respective owners

5

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

1.2. Specifications

• Input voltage: 220 – 230 VAC, 50 – 60 Hz

• Maximum load: 10 A

• Maximum power consumed by EG-PMS: 2.5 W

• Built-in power supply

• Hardware schedule features:

• Maximum number of independent hardware schedule events – 16 per socket

• Time interval between the events – from 1 minute to 180 days

• Timer accuracy: no more than 2 seconds error per day providing power is always present. Otherwise there can be an additional (up to

2 seconds) error per each power off.

• Working temperature range: from +10 to +40 °C

• Dimensions: 378 x 98 x 55 mm

• Net weight: 1.0 kg

1.3. Hardware requirements

• Computer running Windows® 2000/XP/Vista or Windows 7 is required for using the Power Manager software

• One free USB port

All brands and logos are registered trademarks of their respective owners

6

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

1.4. Package contents

The package contains:

• EG-PMS

• User manual

• USB cable

• CD with Power Manager software for Windows

All brands and logos are registered trademarks of their respective owners

7

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

2. Indicators and controls of EG-PMS

Side panel

Figure #1

Main rocker switch (Z)

Non-manageable socket

Indicator

“POWER”

Indicator Socket 4

Socket 4

Socket 3

Socket 2

Socket 1

Indicator Socket 3

Indicator Socket 2

Indicator Socket 1

Non-manageable socket

“Silence” button to suppress beeps

USB Connector

All brands and logos are registered trademarks of their respective owners

8

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

2.1. Side panel

Figure #2

Power cord

Circuit breaker

All brands and logos are registered trademarks of their respective owners

9

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

2.2. Indicators

Main rocker switch Z (see Figure #1 above) is lit – this means that

EG-PMS is connected to the power supply and active

Power indicator (see Figure #1 above) is lit – this means that the non-manageable sockets (marked with the sign switched on

) are

• The indicator Socket 1 (2,3,4) (see Figure #1 above) is lit – this means that this particular socket is switched on

2.3. Audible signals

• Long beep – will be heard after EG-PMS is successfully connected to the computer USB port after the self-test

• Short beep – will be heard by switching the manageable sockets on and off

• Continuous beeps – hardware event schedule is lost – for example if the power supply was cut for a long time. These beeps can be stopped by pressing the Silence button (see Figure #1 above)

• Alarm beep – will be heard if the managing command cannot be executed. E.g. if there is a command to switch the socket on but EG-

PMS is disconnected from the power supply. The alarm will be heard every second during a minute, after that every 8 seconds. Let EG-

PMS execute the command (e.g. switch EG-PMS on) to get rid of the alarm beeps

All brands and logos are registered trademarks of their respective owners

10

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

3. Installation

• It is strongly recommended to avoid damp or wet places for installation.

• EG-PMS should be connected to the European AC wall socket of the standard DIN 49 440.

3.1. Getting started

• Connect EG-PMS to the wall socket first and then to the USB socket of the manageable computer or vice versa.

• EG-PMS can now be switched on and off by means of the Main

rocker switch (Z).

• Two (the first and the last) sockets of EG-PMS are marked with the symbol . These two sockets are switched on and off by means of the Main rocker switch (Z) and cannot be managed by the computer – so they are called non-manageable sockets in this manual.

• If EG-PMS is switched on then the red indicator POWER is lit. In this case both non-manageable sockets are now live and connected to the power supply.

All brands and logos are registered trademarks of their respective owners

11

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

• The sockets: Socket 1, Socket 2, Socket 3 and Socket 4 can be managed or pre-programmed by computer via USB. They are called

manageable sockets in this manual.

• The manageable sockets of EG-PMS can be programmed to be on or off. The current status of each manageable socket is represented by the corresponding indicator which will be lit if socket has power to it.

• If the Main rocker switch (Z) (see figure #1 above) is turned off then the manageable sockets cannot be switched on by either Power

manager software or the hardware schedule.

• As soon as you turn the Main rocker switch (Z) on then the Power

manager software or the hardware schedule will be able to turn the manageable sockets on and off.

• To protect the connected devices from possible high current and short circuit EG-PMS is equipped with the automatic circuit breaker.

NOTE: If the total power consumption (or peak power) of the devices, connected to EG-PMS exceeds 2200 Watts, the circuit breaker may power EG-PMS off. In this case, please, remove the excessive load first and then press the Circuit breaker button to restore the power supply

(see figure #2 above).

All brands and logos are registered trademarks of their respective owners

12

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

3.2. Power Manager installation

• Insert the Power Manager CD into a PC CD-ROM drive.

If for any reason the automatic setup does not work, then open CD-ROM drive in the My Computer window and launch SETUP.EXE from the CD

• Follow instructions of the installation software

4. Power Manager software

The Power Manager software is designed to support not only EG-

PMS but also other products of Energenie family.

After a successful installation a socket icon will appear in your system tray.

4.1. Managing EG-PMS

from the popup menu (see Figure #3 below).

Double click on the socket icon in the system tray or select Open

All brands and logos are registered trademarks of their respective owners

13

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

Figure #3

You will get then the window of the main control panel shown on the

Figure #4 below.

All brands and logos are registered trademarks of their respective owners

14

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

Figure #4

Double click over each socket will switch it on and off (green color means the socket is switched off; red color means the socket is switched on). Click the Settings button for each socket to access the Settings

dialog box (see Figure #5 below).

All brands and logos are registered trademarks of their respective owners

15

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

Figure #5

You can choose a different device and another socket from the

Device and Socket drop down list-boxes.

All brands and logos are registered trademarks of their respective owners

16

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

• It is possible to give a name to the device and socket (for example

Printer or Scanner) using the Rename button

• Check the System tray checkbox if you want to put the icon of the socket into the system tray. You can choose the icon from drop down list box. Such icon is a fast way to switch the device connected to the socket on/off or check the device status

• You can also assign a hot key to switch the socket on/off. Check the

Switch ON and Switch OFF checkboxes and specify the hot keys

• To switch the socket on/off on Windows startup (wake up), check the

On Windows startup checkbox and choose the required action

• To switch the socket on/off on the Windows shutdown (sleep), check the On Windows shutdown checkbox and choose the required action

All brands and logos are registered trademarks of their respective owners

17

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

4.2. Setting up the hardware schedule

Using the Hardware schedule button available from the Settings window you can create the hardware timer schedule (see Figure #6 below). To add a new record, click the Add button.

Figure #6

All brands and logos are registered trademarks of their respective owners

18

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

• The window Add entry will appear (see Figure #7 below). In the dialog box, specify the required time and the action

Figure #7

• To edit the record, select it and click the Edit button or just double click on the entry. The window Edit entry will appear (see Figure #8 below)

All brands and logos are registered trademarks of their respective owners

19

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

Figure #8

• To remove the record, select it and click the Remove button (see

Figure #6 above). You can select multiple entries using Ctrl and Shift keys. You can also remove all entries from the schedule by clicking the Clear button (see Figure #6 above)

• To repeat your event (for example if you want to perform the same events every day) use the Loop button (see Figure #6 above) and specify the loop time period in the Edit loop period window (see

Figure #9 below)

All brands and logos are registered trademarks of their respective owners

20

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

Figure #9

• After the schedule record has been created, click the Apply button

(see Figure #6 above) to save the hardware timer schedule changes.

In case of incorrect entries, these will be highlighted and an error message will appear. Click the Apply button again after correcting all the errors

• Use Sync button (see Figure #6 above) to synchronize device timer with PC clock. Note that after synchronization past entries will be removed from the schedule

HINT: Use the popup menu (see Figure #6 above) which can be activated by the right mouse button click over the table.

The following are the rules for creating a correct schedule:

All brands and logos are registered trademarks of their respective owners

21

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

• The new event time should be in the future

• There can not be a duplicate entry

• The total quantity of events can not exceed 16 per socket

• The total quantity of events also depends on the total execution period of the schedule

• The interval between the present and the last entry can not exceed

180 days

• Without loop the total execution period of the schedule can not exceed 215 days

• Loop period can not exceed 180 days

NOTE: If the device is powered off the hardware schedule is still in the device memory and will be resumed when the power supply is restored. However the whole schedule will be then delayed with the power cutoff time. EG-PMS will then start beeping indicating the hardware schedule problem. Press “Silence” button once to turn the beeps off if you don’t care about the accuracy of your schedule. You can also adjust the schedule eliminating the delay. Every time you press the “Silence” button again after the beeps were off, the schedule will be adjusted with one minute. Alternatively create and upload a new schedule using the ‘Timer schedule’ dialog box.

All brands and logos are registered trademarks of their respective owners

22

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

4.3. Setting up the software schedule

Using the Software schedule button available from the Settings window you can create the software timer schedule (see Figure #10 below).

NOTE: the software timer schedule will only be executed if the managing computer is on and the Power Manager is launched.

All brands and logos are registered trademarks of their respective owners

23

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

Figure #10

• To add a new task, click the Add button. The Add task window will appear (see Figure #11 below)

All brands and logos are registered trademarks of their respective owners

24

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

Figure #11

In the Add task window, check Switch ON time and/or Switch OFF

time checkboxes and specify the time to switch the socked on and/or off.

If you want the same event to be performed periodically, check Perform

task every checkbox and specify the time interval. You can also add remarks about the task in the Comment field. To disable the task, uncheck the Enabled checkbox and to enable the task again, re-check the checkbox.

All brands and logos are registered trademarks of their respective owners

25

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

• To edit the task, select it (see Figure #10 above) and click the Edit button or just double click on the task. The Edit task window will appear (see Figure #12 below)

Figure #12

All brands and logos are registered trademarks of their respective owners

26

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

• To remove the task select it and click the Remove button (see

Figure #9 above). You may select multiple tasks using Ctrl and Shift keys. You can also remove all tasks by clicking the Clear button

HINT: Use the popup menu which can be activated by the right mouse button click over the table (see Figure #10 above).

4.4. Setting up application events

Using the Application events window you can specify the socket events when a certain application is launched or closed down. You can also associate switching the sockets off or on with placement and removal of particular files in certain folders.

To use this feature push Application events button available from the

Settings window (see section 4.1 above – Figure #5). You will get the following window (see Figure #13 below).

All brands and logos are registered trademarks of their respective owners

27

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

Figure #13

• To add a new program event, click the Add app button. The Add

program event dialog will appear (see Figure #14 below)

All brands and logos are registered trademarks of their respective owners

28

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

Figure #14

Specify the application title and path to it using the Browse (…) button or typing it manually in the Title and Path name fields. If you use the Browse (…) button you can also select a shortcut to the application.

In this case the application title and path name will be taken automatically

All brands and logos are registered trademarks of their respective owners

29

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR via the shortcut if possible. After you have specified the application, check On run and/or On exit and choose the event (switch on or off).

NOTE: The On run event will take place when the first window of the selected application is opened. The On exit event will take place when the last window of the application is closed.

HINT: Your device is an advanced standby-killer. Using this feature you can for example switch your scanner on/off whenever Photoshop is started/closed.

• To add a new file event, click the Add folder button (see Figure #13 above). The Add file event window will appear (see Figure #15 below)

All brands and logos are registered trademarks of their respective owners

30

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

Figure #15

Specify the path to the folder you would like to monitor using the

Browse (…) button or typing it manually in the Path name field. Specify the File name mask using wildcard characters: *, ?. Check then On

placing and/or On removal checkboxes and select the event and delay.

NOTE: The On placing event will take place when the first file matching the specified file name mask is placed into the specified folder.

The On removal event will take place when the last file matching the specified file name mask is removed from the specified folder.

All brands and logos are registered trademarks of their respective owners

31

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

HINT: Your device is an advanced standby-killer. Use the Add folder button to assign c:\\system32\\spool\\printers folder to switch your printer on whenever you start printing and to switch it off again whenever you are ready with printing.

HINT: If you have several printers connected to the same computer, we suggest moving default spool directory of each printer to a separate location.

• To edit the event, select it and click the Edit button, or just double click on the event (see Figure #13 above). The Edit file event window will appear (see Figure #16 below)

All brands and logos are registered trademarks of their respective owners

32

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

Figure #16

• To remove the event, select it and click the Remove button (see

Figure #13 above). You can select multiple events using Ctrl and

Shift keys. You can also remove all events by clicking the Clear button

HINT: Use the popup menu which can be activated by the right mouse button click over the table.

All brands and logos are registered trademarks of their respective owners

33

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

5. Power Manager advanced features

The following information is for advanced users which wish to have full access to the advanced features of EG-PMS. Click the Advanced

features button available from the Settings window (see section 4.1 above). The following window will then appear (see Figure #17 below).

Figure #17

All brands and logos are registered trademarks of their respective owners

34

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

5.1. Processing the alarms

Whenever the actual measured voltage on the manageable socket deviates from the status set by your switching tasks, it is called a Voltage

alarm.

The Voltage alarm can for example be caused by a blackout and will be resolved after power returns. The Voltage alarm can also be triggered if for any reason a switching task could not be carried out (switching malfunction).

Voltage alarms are accompanied with beeps (unless “Disable device beeper” option is activated)

The default action by an alarm is to record this event into a log file and show a popup Alarm log window (see Figure #18 below).

Figure #18

All brands and logos are registered trademarks of their respective owners

35

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

You might wish to process this situation in a different way, e.g. send an email message somewhere etc.

• Check the Disable alarm log window checkbox to disable the popup

Alarm log window (applies to all devices)

• Check the When alarm goes on checkbox, then click the Browse(…) button to select the desired program to be launched whenever a voltage alarm is triggered

• Check the When alarm goes off checkbox, then click the Browse(…) button to select the desired program to be launched after the alarm status (see above) is resolved

5.2. Setting up network devices

You can declare EG-PMS as a shared device on your server and let the other users access it via the server.

To make EG-PMS shared on your computer press the button Device

sharing... in the Advanced features window (see Figure #17 above). The window Device sharing will appear (see Figure #19 below)

All brands and logos are registered trademarks of their respective owners

36

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

Figure #19

Set the checkbox Share this device via network if you want to enable the network access to the device (via this PC). To prevent unauthorized access to the device enter the access password in the field Password.

NOTE: The port 6100 should be open. Contact your LAN administrator for further details.

To be able to use this shared EG-PMS on a client PC choose

Shared devices from the Main menu (see Figure #3 above). You will get the following window (see Figure #20 below).

All brands and logos are registered trademarks of their respective owners

37

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

Figure #20

To add a new remote device, press the Add button. You will see the window Add network device (see Figure #21 below).

All brands and logos are registered trademarks of their respective owners

38

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

Figure #21

Enter the network name of the server which is connected to EG-

PMS in the field Hostname. Enter the name of the target EG-PMS in the field Device name. Enter access password in the field Password. To disconnect from the device uncheck the option Enable, set this option on again to regain the access. To locate the shared device in your local network, click the button Find. A dialog box Find network device will

All brands and logos are registered trademarks of their respective owners

39

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR appear. Choose the proper server and then the device and click OK button.

To edit the network device, select it and click the Edit button, or just double click on the network device (see Figure #20 above). The Edit

network device window will appear (see Figure #22 below).

Figure #22

All brands and logos are registered trademarks of their respective owners

40

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

To remove the network device, select it and click the Remove button

(see Figure #20 above) . You can select multiple network devices using

Ctrl and Shift keys. You can also remove all network devices by clicking the Clear button

HINT: Use the popup menu which is available with the right mouse button click over the table.

5.3. Managing device beeper and timer

EG-PMS produces quite a few audible signals (see Section 2.3 above). If these signals are not desirable then set the option Disable device

beeper in the Advanced features window (see Figure #17 above).

Another useful option available from the Advanced features window

(see Figure #17 above) is the tuning of the device timer. Synchronization of the device timer with the managing PC timer is available by using Sync button from the Time schedule window (see Figure #6 above). If the device timer has a certain daily error it can be corrected using this tuning option.

Push Device timer tuning button to access the Device time tuning window (see Figure #23 below)

All brands and logos are registered trademarks of their respective owners

41

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

Figure #23

Enter the correction value (in seconds) which will be applied every

24 hours and push OK button.

5.4. Managing EG-PMS via your own software

To let you switch the sockets from your own applications the following command line interface syntax is supported:

• pm.exe -[on | off] -device name -socket name

Examples:

All brands and logos are registered trademarks of their respective owners

42

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

• "C:\Program Files\Energenie\Power Manager\pm.exe" -on -EG-PM -

Socket1

• "E:\Utils\PM3\pm.exe" -off -My EG-PM -Table lamp

• Execute pm.exe with -info key (pm.exe –info) to get the complete information about the status of the current devices.

For each of the connected devices the following information will then be provided and placed into Info.ini file in the Power Manager folder:

• DeviceName - the user specified device name

• Socket#name, where # is replaced by a certain socket number - the user specified socket name

• Socket#SwitchState, where # is replaced by a certain socket number

- TRUE, when the socket is switched on, FALSE, when the socket is switched off

• Socket#VoltageState, where # is replaced by a certain socket number - TRUE, when voltage presence on the socket is detected,

FALSE, when there is no voltage on the socket;

Example:

All brands and logos are registered trademarks of their respective owners

43

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

NOTE: Each use of this command line option totally overrides the data in Info.ini file.

NOTE: Power Manager should be active.

All brands and logos are registered trademarks of their respective owners

44

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

6. Troubleshooting

Problem

The circuit breaker is activated

(tripped).

The switching command is not carried out, the rocker switch and indicators are not lit.

Software reports "Device I/O request error" after switching

Timer schedule is delayed

Solution

The load connected to the device is too high, some of the devices connected to the EG-PMS should be disconnected and the circuit breaker should be reset.

There is no power supply to the EG-PMS.

Please, make sure the EG-PMS is connected to the power supply and the rocker switch is switched on.

Check the grounding of EG-PMS. If inductive load, like florescent lamps or motors are connected to EG-PMS, it is recommended to use an extra USB hub to connect EG-PMS to the managing computer.

Do not power EG-PMS off when the hardware timer schedule is active. Press the “Silence” button, every push will reduce the delay with one minute.

All brands and logos are registered trademarks of their respective owners

45

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

All brands and logos are registered trademarks of their respective owners

46

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

Waste disposal:

Do not deposit this equipment with the household waste. Improper disposal can harm both the environment and human health. For

Information about waste collection facilities for used electrical and electronic devices, please contact your city council or an authorized company for the disposal of electrical and electronic equipment.

Richtlijnen m.b.t. afvalverwerking

Batterijen en accu’s dienen als kleinchemisch afval afgeleverd te worden bij toegewezen afvalverzamelpunten (zie www.afvalgids.nl). U dient ervoor te zorgen dat de batterijen/accu’s leeg zijn en dus geen stroom meer kunnen leveren. Let op, de batterijen/accu’s dienen onbeschadigd ingeleverd te worden.

Gooi dit product niet weg in uw vuilnisbak. Dit kan zowel het milieu als de menselijke gezondheid schade toebrengen. Informatie over het inleveren van dit product kunt u inwinnen bij uw gemeentelijke vuilnisdienst of andere geautoriseerde instelling in uw buurt.

Entsorgungshinweise:

Werfen Sie dieses Gerät nicht in den

Hausmüll. Unsachgemäße Entsorgung kann sowohl der Umwelt als auch der menschlichen

Gesundheit schaden. Informationen zu

Sammelstellen für Altgeräte erhalten Sie bei

Ihrer Stadtverwaltung oder einer autorisierten

Stelle für die Entsorgung von Elektro-und

Elektronikgeräten.

Traitement des déchets:

Ne jetez pas cet appareil dans les déchets domestiques. Un traitement inapproprié peut

être dommageable à l'environnement et à la santé humain.

Vous trouvez des informations sur les centres de rassemblement des appareils vieux chez l'administration municipale ou chez un centre autorisé pour le traitement des appareils électriques ou électroniques.

All brands and logos are registered trademarks of their respective owners

47

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

WARRANTY CONDITIONS

The warranty period is 36 months and begins with the sale to the end user. The receipt must clearly list the date of purchase and the part number, in addition it should be printed. Keep the receipt for the entire warranty period since it is required for all warranty claims. During the warranty period the defective items will be credited, repaired or replaced at the manufacturer's expense. Work carried out under the warranty neither extends the warranty period nor starts a new warranty period. The manufacturer reserves the right to void any warranty claim for damages or defects due to misuse, abuse or external impact (falling down, impact, ingress of water, dust, contamination or break). Wearing parts

(e.g. rechargeable batteries) are excluded from the warranty. Upon receipt of the RMA goods, Gembird

Europe B.V. reserves the right to choose between replacement of defective goods or issuing a credit note. The credit note amount will always be calculated on the basis of the current market value of the defective products

Gembird Europe B.V.

Wittevrouwen 56, 1358CD Almere

The Netherlands www.gembird.nl/support [email protected]

Tel. +31-36-5211588

(0900-4362473 inside The Netherlands, € 0,15 p/m, mobile costs not included)

GARANTIE BEDINGUNGEN

Die Garantie beträgt 36 Monate ab Verkaufsdatum an den Endverbraucher. Das Kaufdatum und der

Gerätetyp sind durch eine maschinell erstellte

Kaufquittung zu belegen. Bitte bewahren Sie Ihren

Kaufbeleg daher für die Dauer der Garantie auf, da er Voraussetzung für eine eventuelle Reklamation ist. Innerhalb der Garantiezeit werden alle Mängel, wahlweise durch den Hersteller entweder durch

Instandsetzung, Austausch mangelhafter Teile oder im Austausch, behoben. Die Ausführung der

Garantieleistung bewirkt weder eine Verlängerung noch einen Neubeginn der Garantiezeit.

Eine Garantieleistung entfällt für Schäden oder

Mängel die durch unsachgemäße Handhabung oder durch äußere Einwirkung (Sturz, Schlag, Wasser,

Staub, Verschmutzung oder Bruch) herbeigeführt wurden. Verschleißteile (z.B. Akkus) sind von der

Garantie ausgenommen.

GEMBIRD Deutschland GmbH

Coesterweg 45, 59494 Soest

Deutschland www.gembird.de/support [email protected]

Tel. +49-180 5-436247

0,14 € pro Minute aus dem deutschen Festnetz.

Mobilfunkpreise können abweichen

All brands and logos are registered trademarks of their respective owners

48

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

GARANTIE VOORWAARDEN

De garantietermijn bedraagt 36 maanden en gaat in op de aankoopdatum van het product door de eindgebruiker. Op de aankoopbon moeten de aankoopdatum en productomschrijving duidelijk vermeld staan. Gelieve de aankoopbon de gehele garantieperiode te bewaren, deze is ten alle tijden benodigd voor alle garantie aanspraken. Tijdens de garantieperiode zullen alle gebreken verholpen of vervangen worden door de fabrikant d.m.v. reparatie, omruiling van het defecte onderdeel of het gehele apparaat. Aanspraken tijdens de garantieperiode leiden niet tot verlenging hiervan. Garantieaanspraak vervalt bij schade of gebreken die ontstaan zijn door oneigenlijk gebruik, misbruik of invloeden van buitenaf (vallen, stoten, water, stof, vuil of breken).

Slijtagegevoelige onderdelen (b.v. batterijen) zijn uitgesloten van garantie. Bij ontvangst van de RMA goederen behoudt Gembird zich het recht om te kiezen tussen vervanging van de defecte waren of het uitgeven van een kreditnota. Het bedrag van de kreditnota zal altijd gecalculeerd zijn op basis van de huidige marktprijs voor het defecte produkt.

Gembird Europe B.V.

Wittevrouwen 56, 1358CD Almere

The Netherlands www.gembird.nl/support [email protected]

Tel. 0900-4362473

€ 0,15 p/m binnen Nederland

Exclusief mobiele telefoonkosten

CONDITIONS DE GARANTIE

Garantie est de 36 mois a partir de la date d’achat de l'utilisateur final.

Le talon de garantie doit énumérer clairement la date d'achat et le type d'appareil.

Conservez le reçu d'achat pendant toute la durée de la garantie car elle est nécessaire pour toute réclamation.

Au cours de la période de garantie tous les défauts doivent être remplacé aux frais du fabricant, soit par la réparation ou la remplacement de la pièce défectueuse ou l'ensemble du produit.

Les travaux effectués sous garantie ne prolongent pas la période de garantie ni ne commencent pas une nouvelle période de garantie.

Le fabricant se réserve le droit d'annuler toute demande de garantie pour les dommages ou défauts dus à une mauvaise utilisation, abus ou les effets externes (chute, choc, pénétration de l'eau, la poussière, etc..).

Les pièces d'usure (par exemple les piles rechargeables) sont exclus de la garantie.

Dès réception de la marchandise sous garantie, le SAV de Gembird Europe BV se réserve le droit de choisir entre le remplacement des produits défectueux ou de délivrer un avoir.

Le montant d’avoir sera toujours calculée sur la base de la valeur actuelle du marché des produits défectueux.

Gembird Europe B.V.

Wittevrouwen 56

1358CD Almere, The Netherlands www.gembird.nl/support [email protected]

+33(0) 251 404849

Prix d'appel depuis telephone fixe Pays-Bas : 0.15 euro / min

Prix d'appel depuis telephone mobile / autre pays - selon operateur

All brands and logos are registered trademarks of their respective owners

49

EG-PMS

PROGRAMMABLE USB SURGE PROTECTOR

ГАРАНТИЙНЫЙ ТАЛОН

1. Гарантийное обслуживание предоставляется в течение срока гарантии, при наличии правильно и четко заполненного гарантийного талона, и изделия в полной комплектации.

Серийный номер и модель изделия должны соответствовать указанным в гарантийном талоне.

2. Гарантийное обслуживание представляет собой бесплатное устранение всех неполадок (ремонт), или замену изделия на новое (аналогичное).

3. Гарантия не распространяется на неисправности, вызванные следующими причинами:

• использование изделия не по назначению.

• нарушение условий эксплуатации, хранения или перевозки изделия, которые указаны в настоящей инструкции.

• подключение нестандартных или неисправных периферийных устройств, аксессуаров.

• механические повреждения, попадание внутрь изделия посторонних предметов, веществ, жидкостей, насекомых.

• ремонт изделия не уполномоченными на то лицами.

4. Комплектность и внешний вид изделия проверяются

Покупателем при получении товара в присутствии персонала фирмы.

Послепродажные претензии по укомплектованности и внешнему виду не принимаются.

Наименование изделия: ___________________________

Модель _________________________________________

Серийный номер _________________________________

Срок гарантии ___________________________________

Дата продажи «____» ___________________ 20____ года

Фирма-продавец: _________________________________

Адрес и телефон фирмы-продавца:

________________________________________________

М.П. С условиями гарантии ознакомлен и согласен:

Продавец: _____________ Покупатель: _____________

УМОВИ ГАРАНТІЙНОГО ОБСЛУГОВУВАННЯ

1. Гарантійне обслуговування надається протягом терміну гарантії, при наявності Гарантійного талону, заповненого належним чином, та виробу в повній комплектації.

2. Гарантійне обслуговування не підтримується в разі порушення правил експлуатації, зберігання або перевезення виробу, що зазначені в інструкції по експлуатації виробу.

3. Гарантійне обслуговування скасовується у випадках:

- наявності механічних пошкоджень або слідів стороннього втручання;

- пошкодження викликані стихійним лихом або нещасним випадком, включаючи й блискавку, потраплянням у виріб сторонніх предметів, рідин, комах, тощо;

- пошкодження викликані застосуванням або підключенням нестандартних або несправних периферійних пристроїв, аксесуарів;

4. Гарантія не поширюється на витратні матеріали та додаткові аксесуари;

З гарантійними умовами згоден.

Підпис покупця: ____________________

ГАРАНТІЙНИЙ ТАЛОН № __________________________

Товар/модель ____________________________________

Серійний номер __________________________________

Термін гаранії ____________________________________

Дата продажу ____________________________________

Продавець (назва, телефон)

_________________________________________

Печатка та підпис продавця

_________________________________________

З гарантійних питань звертайтесь до сервісних центрів

Gembird. Про адреси та контакти Ви можете дізнатись на сайті www.gembird.ua або по телефону 044-4510213.

All brands and logos are registered trademarks of their respective owners

50

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement