New DAN/DEU/ENG/FR/ITA/NOR/SUO

Description
Connection, accessories, spare parts
Calling
Incoming calls
Outgoing calls
Redial
Three-party calls
Programming the R key
Conference key
Volume control, mute, tuning, ring signal volume
Troubleshooting and maintenance
Technical data
Konftel 100 • User Guide
4
5
6
6
6
6
6
7
8
9
10
11
English
Contents
4
Description
Top
Green/red
mic indicators
Microphone
English
Loudspeakers
Keypad
Bottom
Telephone
line input
(POTS)
Power supply
Keyset
OK key
Conference
key
R key
Up/Down key
Mute/Pause key
Redial key
Konftel 100 • User Guide
Description
5
Connection
240 V
mains outlet
Mains
transformer
Only a mains transformer
type ML120P070G or
FRIWO FW7237/12 may
be connected.
Power supply
and analogue
POTS
network
cable, 7.5 m.
Connectors
underneath
Konftel 100
Accessories
Item No.
9146030
149110
900103339
900103340
900103341
Spare parts
Description
Wall mounting bracket
Ceiling mount suspension with cables
Extension cable, power
supply 10 m
Extension cable,
analogue network, 10 m
Extension cable, power
and analogue network
7.5 m
Konftel 100 • User Guide
Item No.
900103334
826102026
900102026
Description
Power supply and
analogue POTS
network cable, 7.5 m
Mains transformer
12 V DC for UK
Mains transformer
12 V DC for Europe
English
Analogue
telephone line
(POTS)
Calling
6
Incoming calls
A ring signal is heard and the green mic
indicators light to indicate the incoming call.
Press the OK key to answer.
English
To end the call, press OK.
Outgoing calls
Press OK.
0-9...
Dial the number.
To end the call, press OK.
Redial
Press the Redial key. The last number dialled
within 3 sec.
To end the call, press OK.
Three-party calls
Press OK.
0-9...
Enter the number of the first meeting participant.
When the first call is connected, press the
R key to get a new dial tone.
0-9...
Enter the number of the second meeting
participant and wait for answer.
Press the R key followed by the 3 key, and all three can
now participate in the call.
Konftel 100 • User Guide
Calling
7
If your three-party call is not answered
Press the R key followed by the 1 key to return to the first call.
English
Note: The availability and function of the three-party feature can vary from
country to country but also depend on the PBX to which the Konftel 100 is
connected. If you want to connect multiple participants we recommend you use
a telephone meeting service. If you have questions regarding availability, please
contact your dealer.
If the R key does not work
The requirements for the operation of the R key vary between PBXs and from
country to country. Konftel 100 therefore lets you program the R-pulse time so
that it works with most PBXs on the market.
Programming the R key (default setting = 2)
Hold down the R key for three seconds until the green
LEDs flash and you hear three short beeps.
1-5...
Enter the value for the R-pulse. The default setting is 2.
Check in the table below whether the setting is right for
your PBX/country.
Value:
1–R function
2–R function
3–R function
4–R function
5–R function
Time:
65 ms
100 ms
150 ms
270 ms
600 ms
PBX/country:
Ericsson MD110
Scandinavia, Europe
Reserved
Germany, France, Israel
USA
Press the OK key to save the setting and exit.
Konftel 100 • User Guide
8
Conference key
The Conference key gives you the facility to pre-programme a
number or code for your phone conference.
Programming the Conference key
English
Keep the Conference key depressed 3 sec until
the red LEDs flash and you hear a repeating tone.
0-9...
Enter your phone conference number with the
keypad (max 20 digits).
If Konftel 100 must wait for a second dial
tone, you should insert a pause with the Mute/
Pause key.
Press the OK to end and save the number.
Using the Conference key
Press the conference key to connect
to your phone conference.
Press OK to end the call.
Delete the conference number
Keep the Conference key depressed 3 sec until the
red LEDs flash and you hear a repeating tone.
Press OK to delete any conference number.
Konftel 100 • User Guide
9
Volume control, mute,
tuning, ring signal volume
Volume control
Adjust the speaker volume with the Up/Down
key during the call.
Press the Mute key to switch off the microphone. The mic indicators change to red.
Press again to switch on the microphone.
The mic indicators change back to green.
Tuning
The sound is adjusted automatically for the
room and the telephone line when Konftel 100
is switched on. Konftel 100 senses the
acoustics of the room and adapts continuously
during the call. For manual tuning, press the
Up/Down key at the same time. A brief noise
will be heard.
Adjust the ring signal volume
Adjust the volume of the ring signal with the
up/down button. A ringing signal is heard after
every press. It can be adjusted in six steps, of
which the lowest shuts off the ring signal
entirely.
Konftel 100 • User Guide
English
Mute function
10
Troubleshooting
and maintenance
Troubleshooting
1. Check that the microphone is on during the call.
The green microphone indicators must be lit.
English
2. Check that the Konftel 100 is connected to an
analogue telephone jack.
3. Bypass any extension cables and check whether
the system is functioning correctly. If not,
contact your dealer.
4. If Konftel 100 must wait for a second dialling
tone, you should enter a pause with the help of
the pause/mute button when you programme the
number for your phone conference.
Maintenance
Clean the equipment with a dry, soft cleaning cloth.
Do not use any liquids!
Konftel 100 • User Guide
Technical data
11
Konftel 100
Network interface:
Analogue PBX or PSTN, RJ-11.
Power supply and
network cable:
7.5 metre, RJ-11 (line), EIAJ Class IV (power).
Recommended room
conditions:
Reverberation time: <0.5 sec.
Background noise: <45 dB(A).
Frequency response:
200 – 3700 Hz.
Loudspeaker volume:
85 dB SPL.
Room echo suppression:
208 ms.
Line echo suppression:
25 ms.
Automatic calibration:
<1 ms impulse (not discernible).
Dimensions:
Diameter 232 mm.
Weight:
700 g.
Temperature range:
5 – 40° C in operation.
Humidity:
20 % – 80 % non-condensing.
EMC:
EN 50 081-1:1992.
EN 55024:1998.
EN 60950.
Electrical safety:
EN 60950.
Telecom approval:
EUROPEAN TBR21.
Keyboard:
19 keys.
Compatibility:
Konftel 100 can be connected to any PBX equipped
with a POTS extension, for example Ericsson: MD110,
Fenix. Siemens: Hicom. Nortel: Meridan. Philips:
Sopho. Alcatel: 4200, 4400. Ascom: Ascotel.
Konftel 100 • User Guide
English
Mains transformer (Europe): DC transformer 240 V AC/12 V DC; 700 mA.
Mains transformer (UK):
DC transformer 100 - 240 V AC/12 V DC; 700 mA.
Konftel is a leading company within speaker communication and audio technology. We develop
and sell products and technology for telephone meetings based on cutting-edge expertise within
acoustics and digital signal processing. Characteristic of our products is that all conference
telephones contain the same high quality audio technology – OmniSound® – providing crystal
clear sound. Read more about Konftel and our other products on www.konftel.com
Developed by Konftel AB
Box 268, SE-901 06 Umeå, Sweden
Phone: +46 90 706 489 Fax: +46 90 131 435
E-mail: info@konftel.com Web: www.konftel.com
3107-61-001 rev B