8036 SIP Multimedia Intercom Install Guide

8036 SIP Multimedia Intercom Install Guide
This sheet will guide you with the physical
installation of your new 8036 SIP Multimedia
Intercom.
Algo
Security
Tool
For full product documentation, including
configuration, SIP registration, and application
development, please visit
www.algosolutions.com/8036docs
What’s Included
•8036 SIP Multimedia
Intercom (includes
assembled main
housing, removable
Front Bezel, Surface
Mount Bracket, Algo
Logo Badge, and
Security Screw)
Put the Front Bezel, Security Screw, and Logo Badge
aside for re-assembly after mounting.
•Drywall Bracket
•Mounting Gasket
•Algo Security Tool
•Six #8 x 1.5” Type A Pan
Head Phillips Screws
•Six #8 x 1” Type B Pan
Head Phillips Screws
•Ethernet Cable Boot
Flush Mounting into Drywall (Interior)
1. Create a drywall cut out per the template on page
4 of this sheet.
2. Place the Drywall Bracket into wall and bend tabs
around to the front of the drywall to hold in place.
3. After connecting the Ethernet cable, use the #8 x
1.5” Type A Pan Head screws to secure the 8036
housing to the Drywall Bracket.
4. Replace the Front Bezel and keep the Algo Security
Tool in a safe location.
5. Replace the ALGO Logo Badge.
Wall Mounting
The 8036 can be either surface or flush mounted.
The unit is designed to shed rainwater and allow air
ventilation only when oriented in the correct position
(ALGO logo at top) and installed vertically.
The Mounting Gasket and Surface Mount
Bracket are not required for drywall mounting.
Removal of Front Bezel for Installation
The 8036 is shipped partially assembled and must be
partially disassembled
before it can be
installed.
Flush mounting the 8036 on inside drywall
Remove the security
screw behind the
ALGO Logo Badge by
first pressing on one
side of the badge. This
will raise the other
side so that it can be
removed easily by
hand.
Drywall
Bracket
8036 Assembly
Logo Badge
Security Screw
Under Logo Badge
A security bit (“Algo Security Tool”) is included with the
8036 that fits standard socket
screwdrivers. Use the bit in a screwdriver
to remove the security screw and carefully
remove the Front Bezel by pulling at the
top and then disengaging the bottom clip.
Drywall
Front Bezel
#8 x 1.5” Type A Pan Head
(Typical) Six needed
Algo Communication Products Ltd.
4500 Beedie Street
Burnaby, BC Canada V5J 5L2
www.algosolutions.com
260260-02
1
90-00060A
Flush Mounting into Other Materials or
Outdoors
Surface Mounting
The Surface Mount Bracket may be used on a wall
surface where flush mounting is undesirable, or
not practical. The bracket also may be good option
when integrating the 8036 into stonework.
The same guidelines of flush mounting from the
previous section apply, however, the Drywall Bracket
may not be required if the wall material is firm enough
to hold a screw close to the cutout edge. A #8 anchor
may be required (not supplied) for the wall material.
1. Mount the Surface Mount Bracket using the #8 x
1.5” Type A Pan Head screws supplied. For some
wall materials, #8 anchors may be required (not
included).
If outdoors:
1. A rubber Ethernet Cable boot is supplied to be
placed over the network cable prior to terminating
with a plug (see “Network Connection” on page
3).
There is a top and bottom to the Surface
Mount Bracket. Make sure the two drainage
holes are at the bottom.
2. While the 8036 is designed to withstand rain, it
may be undesirable for water to enter the wall
cavity. This can be achieved by sealing the cable
hole prior to mounting or using the Mounting
Gasket between the 8036 and wall. Uneven
surfaces may require a silicon bead around the
8036 after installation.
If outdoors:
a.Ensure any opening in the wall is sealed or
apply a silicon bead between the Surface
Mount Bracket and wall surface around the
outside perimeter.
b.The Ethernet Cable Boot is to be placed over
the network cable prior to terminating with
a plug (see “Network Connection” on page
3).
Flush mounting into an outside wall
Apply thin silicone seal around
opening (mount, then seal)
c. To prevent water from getting behind the
8036, place the Mounting Gasket on to the
back of the 8036 housing prior to mounting.
Mounting Gasket
2. After connecting the Ethernet cable, use the #8
x 1” Type B Pan Head screws to secure the 8036
housing to the Surface Mount Bracket.
3. Replace the Front Bezel and keep the Algo
Security Tool in a safe location. Replace the
ALGO Logo Badge.
The Drywall Bracket is not required when
surface mounting.
Anchors as
Required
#8 x 1.5” Type A Pan Head
(Typical) Six needed
2
Network Connection
Surface mounting on outside wall
The 8036 is powered by the Ethernet PoE network
connection. Typically a network cable is run to the
8036 location and then terminated with a male RJ45
plug.
Optional: Apply thin silicone seal around
perimeter (mount, then seal)
Surface Mount Bracket
Mounting Gasket
If mounting outdoors, slide the Ethernet Cable Boot
onto the cable before installing the RJ45 plug.
8036
Back
PoE
Network
Jack
RJ45 Plug
Ethernet
Cable
Boot
After inserting the plug into the 8036 jack, carefully
position the boot into the jack cavity to prevent
moisture or insects from getting inside.
#8 x 1.5” Type A Pan Head
(Typical) Six needed
#8 x 1” Type B Pan Head
(Typical) Six needed
When inserting
the plug into the
jack, be sure the
plug lock tab is
not accidentally
depressed, creating
a loose connection.
Mounting Height
For most applications, a mounting height of
approximately 55 inches (1.4 m) from floor to center
of display is recommended.
Mounting the 8036 at the proper height
Regulatory Information
The 8036 SIP Multimedia Intercom is
designed and tested to comply with EN
60950-1:2006 safety requirements. When
the unit is connected to wiring that exits the
building, there is potential risk of lightning
induced electrical surges or high voltages
from fault conditions.
97˚ VFOV (x 106H)
6
5
3
2
1
To reduce risk, outdoor wiring should
be protected by Earth grounded conduit
whenever possible. The 8036 is a Power
over Ethernet (PoE) device. The PoE power
source must be a Limited Power Source (LPS),
provided by CAT5 UTP cable, and isolated
from mains by minimum reinforced or double
insulation. Ensure that the PoE injector or
PoE enabled switch carries safety regulatory
approval marks (ie CSA, UL, CE).
Typical 55” (1.4m) to center of 8036
(i.e. middle mounting screw)
4
0
3
2
1
Measurements in Ft.
Lock Tab
0
3
HOLE CUTOUT SIZE FOR FLUSH MOUNT INSTALLATION
This hole template is also available online at
www.algosolutions.com/8036mounting
Cutout along
solid black line
Scale Check
1”
5 cm
4