1 Introduction ................................................................................................................ 1 2 General UC5 System Layout .................................................................................... 2 3 Typical UC5 Height Control System ....................................................................... 4 4 Choosing the Correct Cables ................................................................................... 5 5 Power Cables (Item C30) ......................................................................................... 6 6 Interface Cables: Tilt (Item C20) ........................................................................... 15 7 Interface Cables: Main Lift & Aux (Item C21) ...................................................... 28 8 Valve Cables (Item C10) ......................................................................................... 45 9 Network Cables ....................................................................................................... 50 10 Network Couplers, Plugs & Terminators ............................................................. 52 11 Interface Cables: CANbus ...................................................................................... 56 12 Interface Cables: Switchbox ................................................................................... 71 13 Bus Monitor Cables.................................................................................................. 73 14 Interface Cables: Specialty...................................................................................... 77 1
Introduction
This UC5 Cable Ordering Guide illustrates the available cables for the UC5 system. Please take
the time to read this list to determine necessary cables for your UC5 Height Control System.
Your input can help make us better! If you find issues or have suggestions please don’t hesitate
to contact us.
Phone:
1 800 667 3921
Canada (Toll Free)
1 866 306 6722
United States (Toll Free)
(+33) (0)4 26 47 04 42
Europe
(+1) 306 664 6711
All other regions
E-mail:
service@norac.ca
Web:
www.norac.ca
Every effort has been made to ensure the accuracy of the information contacted in
this document. All parts supplied are selected to specially fit the sprayer to
facilitate a complete installation. However, NORAC cannot guarantee all parts fit
as intended due to the variations of the sprayer by the manufacturer.
1
2
General UC5 System Layout
Figure 1, Figure 2 and Figure 3 illustrate the general layout of the UC5 system components:
Figure 1: General UC5 System Layout (Self Propel Type)
2
Figure 2: General UC5 System Layout (Pull Type)
Figure 3: General UC5 System Layout (Front Mount)
3
3
Typical UC5 Height Control System
Figure 4 depicts a typical UC5 Height Control System. The various cables are listed in this
ordering guide. To choose the most suitable cables, refer to the UC5 installation manual, the
sprayer’s valve connections and the electrical wiring system.
Figure 4: Typical UC5 System
4
4
Choosing the Correct Cables
The following table shows the cables that are required for the main connections in the UC5
system. Refer to Figure 4 for the location of each cable by item number.
5
Item
Part
Number
Available
Lengths
Typical
Length
Quantity
Needed
C01
43220-XX
Control Module to Valve Module:
UC5 Network Cable 14 AWG
0.5,1,3,5,7,10,
15,20 m
10 m
1
C02
43220-XX
Valve Module to Input Module:
UC5 Network Cable 14 AWG
0.5,1,3,5,7,10,
15,20 m
1m
1
C03
43220-XX
Input Module to 8-way Coupler:
UC5 Network Cable 14 AWG
0.5,1,3,5,7,10,
15,20 m
1m
1
C04
Main Lift Sensor to 8-way Coupler:
43220-XX UC5 Network Cable 14 AWG
(This cable is not always required)
0.5,1,3,5,7,10,
15,20 m
3m
1
C05
43210-XX
10,15,20 m
20 m
2
C10
Various
UC5 Valve Cable
0.18,0.9,1.8 m
0.18 m
4
C20
Various
UC5 Tilt Interface Cable
Various
1.5 m
1
C21
Various
UC5 Main Lift, Bypass & Slant Interface Cable
Various
1.5 m
1
C30
Various
UC5 Battery Cable
Various
1.5 m
1
Description
Wing Sensor to 8-way Coupler:
UC5 Network Cable 18 AWG
5
Power Cables (Item C30)
All power cables are 60” (1.5m) in length unless otherwise noted.
5.1
43250-04 (Rev C) – CABLE UC5 BATTERY AMP FUSED
5.2
43250-06 (Rev C) – CABLE UC5 BATTERY PIGTAIL FUSED
6
5.3
43250-07 (Rev C) – CABLE UC5 BATTERY JD FUSED
5.4
43250-08 (Rev C) – CABLE UC5 BATTERY AMP TEE FUSED
7
5.5
43250-09 (Rev C) – CABLE UC5 BATTERY GP TEE FUSED
8
5.6
9
43250-10 (Rev A) - UC5 NETWORK POWER JUMPER
5.7
43250-11 (Rev D) - CABLE UC5 BATTERY PIGTAIL
(30” [0.75m])
5.8
43250-12 (Rev C) - CABLE UC5 BATTERY PIGTAIL FUSED
(ECU & SIG)
10
5.9
43250-13 (Rev C) - CABLE UC5 BATTERY AMP FUSED
(ECU & SIG)
5.10
43250-14 (Rev C) - CABLE UC5 BATTERY 2-PIN DT FUSED
(ECU & SIG)
11
5.11
43250-16 (Rev C) - CABLE UC5 BATTERY 6-PIN DT FUSED
(ECU & SIG) (52” [1.3m])
12
5.12
43250-17 (Rev E) - CABLE UC5 POWER RETROFIT FOR ECHO
SWITCH FUSED
Connects an ECHO with a power switch to control modules with serial numbers 3000 and
lower.
13
5.13
43250-18 (Rev A) - CABLE UC5 BATTERY FUSED (ECU & SIG)
5.14
43250-19 (Rev A) - CABLE UC5 BATTERY 4-PIN DT FUSED
(ECU & SIG) (20” [0.5m])
14
6
Interface Cables:Tilt (Item C20)
All tilt interface cables are 60” (1.5 m) in length unless otherwise noted.
Used to interface with sprayer hydraulic and wing valves.
6.1
15
43240-01 (Rev C) – CABLE UC5 INTERFACE TILT DT
6.2
43240-02 (Rev C) – CABLE UC5 INTERFACE TILT MP
(METRIPACK 150)
16
6.3
17
43240-06 (Rev C) – CABLE UC5 INTERFACE TILT JD
6.4
43240-08 (Rev D) – CABLE UC5 INTERFACE TILT AMP
(SUPERSEAL)
18
6.5
19
43240-11 (Rev C) – CABLE UC5 INTERFACE TILT DIN
6.6
43240-13 (Rev C) – CABLE UC5 INTERFACE TILT GP
(WEATHERPACK)
20
6.7
21
43240-15 (Rev C) – CABLE UC5 INTERFACE TILT MP
(METRIPACK 280)
6.8
43240-17 (Rev C) – CABLE UC5 INTERFACE TILT PIGTAIL
22
6.9
23
43240-19 (Rev C) – CABLE UC5 INTERFACE TILT JD
(4920, 4930)
6.10
43240-25 (Rev C) – CABLE UC5 INTERFACE TILT MP (NITRO)
24
6.11
25
43240-33 (Rev B) - CABLE UC5 INTERFACE TILT GP
(REVERSED POLARITY)
6.12
43240-40 (Rev A) - CABLE UC5 INTERFACE TILT METRIPACK
150 (REVERSED POLARITY)
26
6.13
27
43240-41 (Rev A) - CABLE UC5 INTERFACE TILT DT R4038
7
Interface Cables: Main Lift & Aux (Item C21)
All main lift interface cables are 60” (1.5 m) in length unless otherwise noted.
Used to interface with sprayer main lift, directional and bypass valves.
7.1
43240-04 (Rev C) – CABLE UC5 INTERFACE MAIN MP
(METRIPACK 150)
28
7.2
29
43240-05 (Rev D) – CABLE UC5 INTERFACE MAIN JD
7.3
43240-07 (Rev C) – CABLE UC5 INTERFACE MAIN DT
(WITH AUX 1 & 2)
30
7.4
31
43240-09 (Rev E) – CABLE UC5 INTERFACE MAIN AMP
(SUPERSEAL 240" [6.1m] W/ BYPASS)
7.5
43240-10 (Rev D) – CABLE UC5 INTERFACE MAIN GP
(240” [6.1m] LENGTH)
32
7.6
33
43240-12 (Rev C) – CABLE UC5 INTERFACE MAIN DIN
(WITH AUX 1, 2 & 3)
7.7
43240-14 (Rev C) – CABLE UC5 INTERFACE MAIN GP
(WEATHERPACK)
34
7.8
35
43240-16 (Rev C) – CABLE UC5 INTERFACE MAIN MP
(METRIPACK 280)
7.9
43240-18 (Rev D) – CABLE UC5 INTERFACE MAIN PIGTAIL
36
7.10
37
43240-20 (Rev D) - CABLE UC5 INTERFACE MAIN JD
(4920, 4930)
7.11
43240-21 (Rev D) - CABLE UC5 INTERFACE MAIN MP
(NITRO) (372” [9.5m])
38
7.12
39
43240-22 (Rev C) - CABLE UC5 INTERFACE MAIN DT
(240” [6.1m] LENGTH)
7.13
43240-31 (Rev B) - CABLE UC5 INTERFACE MAIN DT
(WITH AUX 1, 2 & 3)
40
7.14
41
43240-32 (Rev B) - CABLE UC5 INTERFACE MAIN GP
(REVERSED POLARITY)
7.15
43240-35 (Rev B) - CABLE UC5 INTERFACE GVM MAIN LIFT
AND BYPASS
42
7.16
43
43240-38 (Rev B) – CABLE UC5 INTERFACE JOHN DEERE
R4030 4038 ML
7.17
43240-39 (Rev A) - CABLE UC5 INTERFACE MAIN
METRIPACK 150 (REVERSED POLARITY)
44
8
Valve Cables (Item C10)
Connects the NORAC valve module to the NORAC valve block.
8.1
43230-01 (Rev A) – CABLE UC5 VALVE 2 PIN DT TO BLACK
DIN (8” [0.2m])
8.2
43230-04 (Rev A) – CABLE UC5 VALVE 2 PIN DT TO 2 PIN DT
(8” [0.2m])
45
8.3
43230-06 (Rev A) – CABLE UC5 VALVE 2 PIN DT TO 2 PIN DT
(36” [0.9m] LENGTH)
8.4
43230-07 (Rev C) – CABLE UC5 VALVE 2 PIN DT TO 2 PIN DT
(84” [2.1m] LENGTH)
46
8.5
43230-08 (Rev B) – CABLE UC5 OUTPUT VERSION 2PIN DT
TO 2PIN DT TEE (L = 36" [0.9m])
8.6
43230-09 (Rev B) – CABLE UC5 VALVE 2PIN DT TO 2PIN DT
TEE DIODE & RESISTOR (L = 36" [0.9m])
47
8.7
43230-14 (Rev B) - CABLE UC5 VALVE LOCK HAGIE 2014
(30” [0.75m])
48
8.8
49
43230-16 (Rev A) - CABLE UC5 VALVE HAGIE 2014 120'
(20” [0.5m])
9
9.1
Network Cables
43210-XX (Rev A) - CABLE UC5 NETWORK 18 AWG
The “XX” in the part number denotes the cable length. Replace it with the cable length
required. Cables are available in: 10, 15 and 20 meter lengths (395”, 595” and 780”).
50
9.2
43220-XX (Rev A) - CABLE UC5 NETWORK 14 AWG
The “XX” in the part number denotes the cable length. Replace it with the cable length
required. Cables are available in: 0.5, 1, 3, 5, 7, 10, 15 and 20 meter lengths (20”, 40”, 120”,
200”, 275”, 395”, 595” and 780”).
51
10
10.1
Network Couplers, Plugs & Terminators
43760 (Rev C) – UC5 NETWORK COUPLER 3-WAY
(ITEM E10)
52
10.2
53
43765 (Rev A) – UC5 NETWORK COUPLER 8-WAY
(ITEM E11)
10.3
43764 (Rev B) – UC5 NETWORK COUPLER 2-WAY
(ITEM E12)
10.4
43764T (Rev B) – UC5 NETWORK COUPLER 2-WAY
WITH TERMINATOR (ITEM E20)
54
10.5
106034 – UC5 NETWORK 2 PIN PLUG (ITEM P01)
10.6
106602 – UC5 NETWORK 12 PIN PLUG (A-KEY) (ITEM P02)
10.7
105882 – UC5 NETWORK 6 PIN PLUG (ITEM P03)
55
11
Interface Cables: CANbus
Used to interface with the existing sprayer CANbus.
11.1
43240-28 (Rev C) – CABLE UC5 INTERFACE CAN BUS
(PIGTAIL) (30” [0.75m])
56
11.2
57
43260-01 (Rev C) – CABLE UC5 INTERFACE CAN BUS
(3 PIN DT) (12” [0.3m])
11.3
43260-02 (Rev B) – CABLE UC5 INTERFACE CAN BUS
VT JD GS2 (40” [1.0m])
58
11.4
59
43260-07 (Rev B) – CABLE UC5 INTERFACE CAN BUS
3 PIN DT J1939 (12” [0.3m])
11.5
43260-08 (Rev B) – CABLE UC5 INTERFACE CAN BUS
4 PIN DT (40” [1.0m])
60
11.6
61
43260-09 (Rev D) – CABLE UC5 INTERFACE CAN BUS
6 PIN METRI-PACK 150 (16” [0.4m])
11.7
43260-10 (Rev C) – CABLE UC5 INTERFACE CAN BUS
(3 PIN DT) (36” [0.9m])
62
11.8
63
43260-16 (Rev A) - CABLE UC5 INTERFACE CAN BUS
CCI 100/200 DISPLAY (80” [2.0m])
11.9
43260-17 (Rev A) - CABLE UC5 INTERFACE CAN BUS
MUELLER VT (8” [0.2m])
64
11.10 43260-19 (Rev A) - CABLE UC5 INTERFACE IBIC (80” [2.0m])
65
11.11 43260-21 (Rev A) - CABLE UC5 TEE JET MATRIX 570
(36” [0.9m])
66
11.12 43260-28 (Rev A) – CABLE UC5 CANBUS VT JD R403X
(40” [1.0m])
67
11.13 43260-29 (Rev B) – CABLE UC5 INTERFACE DT 4 PIN 12 IN
STUB (12” [0.3m])
68
11.14 43260-30 (Rev B) – CABLE UC5 INTERFACE DTM 4 PIN 12 IN
STUB (12” [0.3m])
69
11.15 43260-31 (Rev A) – CABLE UC5 INTERFACE HD16 9 PIN TO 6
PIN DT (12” [0.3m])
70
12
12.1
71
Interface Cables: Switchbox
43240-26 (Rev C) – CABLE UC5 INTERFACE SWITCH BOX
(480” [12.2m])
12.2
43240-27 (Rev B) – CABLE UC5 INTERFACE SWITCH BOX
EXTENSTION (140” [3.6m])
72
13
13.1
73
Bus Monitor Cables
44644-06 (Rev A) - CABLE BUS MONITOR ADAPTER
(12” [0.3m])
13.2
44644-08 (Rev A) - CABLE BUS MONITOR
(DT FEMALE TO AMP MALE) (10” [0.25m])
13.3
44644-10 (Rev A) - CABLE BUS MONITOR
UC5 SENSOR ADAPTER (10” [0.25m])
74
13.4
75
44644-11 (Rev A) - CABLE BUS MONITOR PEAK PCAN TEE
(MALE & FEMALE DT) (42” [1.1m])
13.5
44644-12 (Rev A) - CABLE BUS MONITOR
(DT MALE TO AMP FEMALE) (10” [0.25m])
13.6
44644-14 (Rev A) - CABLE UC5 TEST - VALVE MODULE
OUTPUT – LED (6” [0.15m])
76
14
14.1
77
Interface Cables: Specialty
43240-30 (Rev C) - CABLE UC5 INTERFACE HARDI DAH09
(40” [1.0m])
14.2
3240-34 (Rev B) - CABLE UC5 INTERFACE HARDI DAH09 TF
ADAPTER (8” [0.2m])
78
14.3
79
43240-37 (Rev A) - CABLE UC5 INTERFACE HAGIE 2014
(26” [0.7m])
14.4
43260-11 (Rev D) - CABLE UC5 NETWORK HAGIE STS
CHASSIS TO BOOM DISCONNECT
(135” [3.4m])
80
14.5
81
43260-12 (Rev C) - CABLE UC5 NETWORK HAGIE STS BOOM
DISCONNECT TO 8-WAY (168” [4.3m])
14.6
43260-13 (Rev B) - CABLE UC5 NETWORK HAGIE STS CAB
TO BULKHEAD (20” [0.5m])
82
14.7
83
43260-14 (Rev B) - CABLE UC5 NETWORK HAGIE STS
BULKHEAD TO VIM (36” [0.9m])
14.8
43260-15 (Rev C) - CABLE UC5 HAGIE STX INTERFACE
(84” [2.1m])
84
14.9
43260-20 (Rev A) - CABLE UC5 NETWORK 14AWG
(415” [10.5m]) WITH LIQUID TIGHT
CONNECTOR
14.10 43260-22 (Rev A) - CABLE UC5 NETWORK 14AWG
(335” [8.5m]) WITH LIQUID TIGHT
CONNECTOR
85
14.11 43260-23 (Rev A) - CABLE UC5 NETWORK 14AWG
(138” [3.5m]) WITH LIQUID TIGHT
CONNECTOR
86
14.12 43260-24 (Rev A) - CABLE UC5 NETWORK HAGIE STS CAB
TO BOOM DISCONNECT (101” [2.6m])
87
14.13 43260-26 (Rev A) – CABLE UC5 NETWORK HAGIE 12 PIN DT
(B-KEY) TO 6 PIN DT (90” [2.3m])
88
14.14 43260-27 (Rev A) - CABLE UC5 NETWORK HAGIE 12 PIN DT
(B-KEY) TO 6 PIN DT (10” [0.25m])
89
Canada
NORAC Systems International Inc.
Phone: (+1) 306 664 6711
Toll Free: 1 800 667 3921
Shipping Address:
3702 Kinnear Place
Saskatoon, SK
S7P 0A6
United States
NORAC, Inc.
Phone: (+1) 952 224 4142
Toll Free: 1 866 306 6722
Shipping Address:
6667 West Old Shakopee Road, Suite 111
Bloomington, MN
55438
Europe
NORAC Europe sarl
Phone: (+33) (0)4 26 47 04 42
Shipping Address:
Rue de l’hermitage
01090 Guereins
France
www.norac.ca
Download PDF
Similar pages