Amplifier
Terrestrial and SAT amplifier
CNV 11 F
•
•
•
•
•
•
•
•
Remote feed Post-amplifier terrestrial and
SAT signals
Remote feed of LNB´s
via the HF cable
For single antenna systems
with longer cable sections
One input, one output
Operating voltage of the LNBs
and of the post-amplifier is
provided by the receiver or by
the multiswitch
Line equaliser LES 2020 F for compensating the frequencydependent cable attenuation in
the distribution network at the
end of this section
Satisfies EN 50083-2
Type
CNV 11 F
CNV 235 E
Order number
947 764-001
947 643-002
47-862 MHz
Gain
Level attenuator
Line equaliser
Isolation IN / IN
Isolation OUT / OUT
Output level
Noise factor
Return loss on
Return loss off
950-2150 MHz
Gain
Level attenuator
Line equaliser
Isolation SAT in/in
Isolation SAT out/out
Isolation SAT on/out
Output level
CNV 235 E
•
•
•
•
•
•
Post-amplifier for
compensating the
attenuation losses in the
distribution network
Selective signal
amplification of the
terrestrial and two SAT
signals
Level adjuster -20 dB for each band
Line equalisers for each range.
Power supply via the DC input with
provided power pack
Satisfies EN 50083-1, 2
Noise factor
Return loss in
Return loss out
2150-2400 MHz
Gain
Isolation SAT in/in
Isolation SAT out/out
Isolation SAT on/out
Output level
Noise factor
Return loss in
Return loss out
Operating conditions
Remote feed voltage, current
Operating voltage
Current consumption
Power consumption
Weight
Dimensions
Operating voltage
Operating temperature
1) in
12 dB
5 dB
951 /1132 dBµV
29 dB
0...20 dB
0...20 dB
60-55 dB
20-18dB
1081 / 1182 dBµV
5 dB
5 dB
12 dB
12 dB
13-21 dB
36 dB
0...20 dB
0...20 dB
60 dB
55 dB
60 dB
1103 / 1214 dBµV
1033 / 1154 dBµV
6 dB
8 dB
10 dB
10 dB
20 dB
27 dB
55 dB
55 dB
55 dB
1073 / 1184 dBµV
1033 / 1134 dBµV
6 dB
8 dB
8 dB
max 450 mA
13-18V
35 mA
approx. 0.6 W
0.6 kg
80 x 44 x 25 mm
1.5 kg
285 x 115 x 70 mm
230V~/50-60Hz
-20°C to +60°C
accordance with EN 50083, Part 5 for interference products, second order at 60 dB IMA
accordance with EN 50083, Part 5 for interference products third order at 60 dB IMA
3) in accordance with EN 50083, Part 5 for interference products, second order at 35 dB IMA
4) in accordance with EN 50083, Part 5 for interference products third order at 35 dB IMA
All values with level adjuster on 0 dB and linear frequency response (equalisation 0 dB)