Product Data Sheet
ATS1250
ATS Intelligent 4 door controller
Data Gathering Panels
Data Gathering Panels (DGP) are used to expand the number
of alarm inputs on the system and allow inputs and relays to be
connected at a location remote from the Advisor MASTER
panel. DGPs communicate via poll & reply messages and send
alarms to the control panel for processing. The DGPs collect
information from detectors, door contacts and other similar
devices. There are DGPs available for conventional devices,
wireless devices as well as for intelligent addressable devices.
A special DGP is also available for collecting the information for
either four doors or lifts.
Product Overview
The ATS1250/1260 4-Door/Lift DGP is a versatile access
control panel to extend the Advisor MASTER system with
advanced access control functions. Real time alarm and access
control on 4 doors, with power supply and housing. A total of 12
ATS1250 can be connected to an Advisor Master panel. To
program both the controllers a user interface with liquid crystal
display must be included in the system. The 4-door controller
can operate off-line with no degradation in performances,
should communication with the Advisor Master panel fail.
Standard Features
E
E
E
E
E
E
E
E
Extensive programming features
E
Can be used to program a sequence of unique events for a
desired outcome (macro logic). For example when a user
badges a card or selects a floor, lights in the area can be
programmed to turn on or a macro can activate a light on a map
at a security desk to indicate a floor has been accessed.
E
Connectivity
A total of 12 ATS 1250 or ATS 1260 can be connected to an
Advisor Master panel. To program both the controllers a user
interface with liquid crystal display must be included in the
system.
Communications
The controllers can be mounted up to 1.5 km from the Advisor
Master panel, which will continuously check if the controller is
still on line. The 4-door controller and the 4-lift controller can
operate off-line with no degradation in performances, should
communication with the Advisor Master panel fail.
Users
The 4-door controller and the 4-lift controller are using the user
information from the Advisor Master panel. The number of card
E
E
Real time alarm & access control on 4 doors
Full mirror database for offline condition
Max 12 4-door controllers and 48 intelligent doors/panel
Global anti-passback
Region control
User counter, interlocking, card + PIN
16 alarm inputs on board
4 reader inputs with built-in interface
Local RS485 bus for up to 16 readers
Wide range of third party readers supported
4 relays on board for lock strikes
52 programmable outputs
ATS1250
ATS Intelligent 4 door controller
users is 11466. 1000 users can be programmed with a PIN
code and with a name.
Ordering Information
Part No.
Description
ATS1250
ATS Intelligent 4 door controller
ATS1250MBC
ATS1250 Mother Board Card
ATS1260UP
ATS Intelligent 4-Lift Controller Upgrade Package
ATS1251
ATS Intelligent 4-door Controller, 12V, Big Enclosure
ATS1252
ATS Intelligent 4-door Controller, 24V, Big Enclosure
ATS1253
ATS Intelligent 4-door Controller, 12V, Small Enclosure
ATS1254
ATS Intelligent 4-door Controller, 24V, Small Enclosure
Door groups
ATS1160N
ATS Mifare DESFire & EV1 Reader with Output & RTE
The 4-door controller is also using the door groups from the
Advisor Master panel. Standard there are 128 door groups
available.
ATS1161N
ATS Mifare DESFire & EV1 Reader with PIN, output & RTE
ATS1170
ATS Reader interface (Single door controller)
ATS1151
ATS Aluminium Keypad
ATS1156
ATS Aluminium Magstripe Card Reader With Keypad
ATS1190X4
ATS Smart Card Reader 4 pcs
ATS1190
ATS Smart Card Reader
ATS1192X4
ATS Heavy-duty Smart Card Reader 4 pcs
ATS1192
ATS Heavy-duty Smart Card Reader
ATS1197
ATS Smart Card Reader with keypad
ATS1471
ATS keyfob
ATS1473
ATS keyfob, blue
ATS1475
ATS proximity card, packed by 10 pcs.
ATS1477
ATS fibertag.
Access control procedures
Access control procedures like swiping a card or entering a PIN,
can be programmed to function only within particular blocks of
time or outside those times. For example, during a period
deemed as a high security risk, granting access may require a
PIN and card to be presented at reader. At another time of low
security risk, access to the same area may be gained with only
the presentation of a card.
Timezones and holidays
The controllers can use one or more of the 24 free
programmable time zones and 24 holiday slots.
Inputs
Both controllers have 16 four state monitored inputs on board.
On the 4-door controller, by default 12 inputs are assigned to
DOTL alarm, Egress and door contacts, but they can also be reprogrammed as regular inputs.
Readers
The ATS 1250 and ATS 1260 support many reader formats
including magnetic swipe, PIN code, proximity and Wiegand.
Specifications
Power supply
Battery test
Max. distance from panel
Specified cable
Data bus monitoring
Addressing
Users
PIN codes
Door groups
Time zones / Holidays
Zones
Relays
Operating temperature
Mains transformer
Housing dimensions (W x H
x D)
13.8 VDC / 3 A
Dynamic battery testing
1.5 km
Aritech WCAT 52/54 or equivalent
Continuous monitoring for off-line conditions of
all devices on bus
Individually addressed via DIP switches
11466 cardholders (expandable to 65535 with
IUM)
1000 dependant on panel memory options
128
24 / 24
16 (free programmable inputs)
4 on-board (expandable to 52 with relay cards)
0 to +50°C
230 V 50 Hz/23 VAC 120 VA
475 x 460 x 160 mm
As a company of innovation, UTC Fire & Security reserves the right to change product
specifications without notice. For the latest product specifications, visit UTC Fire & Security
online or contact your sales representative.
ATS1250-2017-07-25 18:08:11 Released :28-FEB-17