installation instructions

INSTALLATION INSTRUCTIONS
CALEDONIA 06-4091HS / 06-4091HSSN
ROMAN TUB FAUCET
5
HANDLE INSTALLATION
Install handles (1) and tighten the set screw (2).
THIS FAUCET MEETS OR EXCEEDS THE FOLLOWING STANDARDS:
ASME A112.18.1/CSA B125.1 and NSF-61
1
THANK YOU FOR PURCHASING THIS TAYMOR PRODUCT. ALL TAYMOR PRODUCTS ARE CAREFULLY
ENGINEERED AND FACTORY TESTED TO PROVIDE LONG TROUBLE-FREE USE UNDER NORMAL CONDITIONS.
HAVE BASIC TOOLS READY
1
2
Your installation may require new supply
lines. (Supply lines are not included.)
SIL
ICO
NE
RECOMMENDED TOOLS:
Teflon tape Screwdrivers
Adjustable
wrench and
pipe wrench
Flashlight
Safety goggles
Torque wrench
Plumber’s putty
Silicone caulk
6
DIVERTER INSTALLATION
WARNING: READ ALL the instructions completely before beginning.
READ ALL warnings, care and maintenance information.
Taymor recommends calling a professional if you are uncertain about installing this product!
A
This product should be installed in accordance with all local and provincial plumbing and building codes.
Need Help? Please call our toll-free Customer Support line at
(WEST) 1-800-267-4774 (EAST ) 1-800-387-7064 for additional assistance or service.
Remove spout (1) from diverter body (2).
1
1
TURN OFF THE MAIN WATER SUPPLY
2
B
Remove lift rod knob (1) and remove set
screw (2).
Locate water supply inlets and shut off water supply valves.
These are usually found near water meter.
2
TURN OFF
TURN OFF
2
DECK PREPARATION
3
Drill holes in FINISHED DECK per diagram.
NOTE: This kit is intended for installation up to 1-1/4” thick.
5"
mi
n. (
12
C
D
Remove connector (1) from diverter body (2).
From underneath the deck, insert diverter
body with rubber washer (1), metal washer
(2) and mounting nut (3) through center hole.
From above, thread connector (4) onto diverter body. Tighten mounting nut (3), so that
the connector (4) sits flush to the surface of
working area.
1
.7c
in.
m) 3" m m)
6c
(7.
Ø1-3/8”
(35mm)
8~
16
4
"( 2
0.3
-4 0
.6c
m
)
Ø1-1/8”
(29mm)
1-1
/8”
4~
(29
Ø1-3/8”
(35mm)
6"(
10
mm
)M
AX
.2 -
.D
15
EC
.2c
m)
KT
HIC
KN
ES
2
1
2
3
TORQUE
11 - 15 FT/LBS.
Ø1-3/8”
(35mm)
S
INSTALL THE VALVE SYSTEM
4
7
A
Remove flange (1) from housing assembly.
B
1
SPOUT INSTALLATION
Assemble and align spout (1) onto diverter body and tighten set screw (2). Insert index
(5). Place lift rod knob (3) onto lift rod (4) and hand tighten.
With the housing assembly marked “HOT” on
the left, insert the housing assembly through
the mounting holes from the underside of the
deck/rim.
1
3
1
2
5
4
C
Place a flange on each housing assembly.
Thread each flange down. Adjust each lower
locknut and washer. Wrench tighten locknuts.
D
Place a handle flange on each housing
assembly. Thread each handle flange down.
TORQUE
11 - 15 FT/LBS.
TORQUE
11 - 15 FT/LBS.
CUSTOMER SERVICE
WEST 1-800-267-4774 | EAST 1-800-387-7064 | taymor.com
® REGISTERED TRADEMARK OF TAYMOR INDUSTRIES LTD.
INSTALLATION INSTRUCTIONS
CALEDONIA 06-4091HS / 06-4091HSSN
ROMAN TUB FAUCET
8
A
HOSE GUIDE INSTALLATION
11
B
Insert hose guide (1) into deck.
From underneath deck, secure hose guide
with rubber washer (1), metal washer (2)
and locknut (3). Wrench tighten.
FLUSHING
Turn on hot and cold water supplies and flush the
water lines for one minute. Pull hose to its farthest
extension and point it down into the tub. Pull the lift
rod up to the full ON position and flush water lines
for one minute. After flushing, turn the handles all
the way off to shut off the water. The lift rod should
now be in its normal position.
1
1
1
2
TORQUE
11 - 15 FT/LBS.
C
3
12
HAND HELD SHOWER INSTALLATION
2
Connect hand held shower (1) into the end of the elbow (2)
by turning clockwise. Hand tighten.
Connect the valve body outlets to the
diverter body inlets using high flow flexible
lines supplied.
CAUTION: Check all connections for leaks.
Failure to do so can result in water damage.
13
9
A
SPRAY HOSE CONNECTION
B
Insert coiled spray hose (1) through hose
guide (2).
EXPLODED DIAGRAM FOR REFERENCE
MAINTENANCE Your new faucet is designed for years of trouble-free performance.
Keep it looking new by cleaning it periodically with a soft cloth. Avoid abrasive cleaners,
steel wool and harsh chemicals as these will dull the finish and void your warranty.
1 - LIFT ROD KNOB
Carefully thread and tighten one end of the
braided connector hose (1) to the coiled
spray hose (2) and one end to the diverter
body (3). Restrain coiled spray hose (2) with
clip (4).
2 - LIFT ROD
4 - SPOUT
1
3 - INDEX
10 - HANDLE SEAT
2
11 - HANDLE
5 - SET SCREW
7 - DISC
8 - O-RING
6 - RECTIFIER
12 - SET SCREW
9 - VALVE
3
13 - O-RING
14 - CONNECTOR
15 - INVERTER
16 - HANDLE FLANGE
2
37 - HAND HELD SHOWER
4
39 - SET SCREW
17 - DIVERTER
1
40 - O-RING
18 - O-RING
10
WATER SUPPLY CONNECTION
38 - SHOWER FLANGE
19 - CONNECTOR
26 - BONNET
41 - ELBOW
27 - CARTRIDGE ASSEMBLY
20 - O-RING
Connect water supply lines (1) to housing assembly (2). Hot water supply lines go into
left inlet. Cold water supply lines go into right inlet. (Supply lines not included.)
21 - WASHER
22 - RUBBER
WASHER
28 - FLANGE
42 - LONG SHANK
29 - FLANGE
WASHER
43 - WASHER
23 - METAL
WASHER
30 - RUBBER WASHER
24 - LOCKNUT
31 - METAL WASHER
32 - LOCKNUT
44 - RUBBER
WASHER
45 - METAL
WASHER
46 - NUT
25 - BODY
47 - CLIP
2
33 -HOUSING
ASSEMBLY
1
48 - COILED
SPRAY
HOSE
TORQUE
6 - 10 FT/LBS.
2
34 - COUPLING NUT
1
35 - HIGH FLOW FLEXIBLE LINES
36 - BRAIDED CONNECTOR HOSE
CUSTOMER SERVICE
WEST 1-800-267-4774 | EAST 1-800-387-7064 | taymor.com