hyl series 80w, 50w nickel plated sanitary lighting systems

CANTY
PROCESS TECHNOLOGY
HYL SERIES 80W, 50W NICKEL PLATED SANITARY LIGHTING SYSTEMS
APPLICATIONS
x
x
x
x
x
Process Vessels and Equipment
Pressure Vessels
Sterilizers
Diving Decompression Chambers
Altitude and Environmental Chambers
Many, many more
SPECIFICATIONS
Light Pipe
Pressure:
Mounting:
HOW IT WORKS
The HYL 50 and HYL 80 lights are designed to
illuminate pressurized, irradiated or isolated areas.
The HYL lighting package provides a compact, cost
effective lighting system. Our patented design allows
for an intense beam of light to cross the
pressure/process boundary. Once across, the beam
can be diffused to produce conical light outputs of
30° (normal beam) or 90° (wide beam). The HYL
light can mate with a variety of couplings, including
flanged, sanitary and NPT connections.
x
x
x
x
Nickel Plated Aluminum Light Source.
Pressure rating from full vacuum to 10,000
PSI available. Consult factory.
NEMA 4, IP 66 ratings available.
Explosion proof Class I, Div. 1, Groups B, C
and D, Class II, Div. 1, Groups E, F and G,
and NEMA 4 models.
Flame proof Ex II 2 GD, Eex d IIC T6 and IP
66 models.
Efficient high output tungsten halogen lamp.
All wiring and maintenance external.
CANTY
Light Source
Rating:
WP, IP 66, EXP and FP available
Power Req: 50 VA max (50W models),
80 VA max (80W models)
Typ. Max Tank Specification
50W:
8 ft [2.4m] dia. X 12 ft [3.7m] dp.
80W:
25 ft [7.6m] dia. X 70 ft [21.3m] dp.
Power Supply
Options:
Base Mount (non WP), OEM (bare
transformer), WP/IP, EXP/FP,
customer supplied PSU Options
UNIQUE DESIGN
FEATURES
x
x
Full Vacuum to 10,000 PSI
available. Consult factory.
1” NPT, flanged and sanitary
models available
JM Canty Inc
JM Canty Intl Ltd
Buffalo, NY USA
Dublin, Ireland
Our patented design consists of three main
components: light source, light pipe and power
supply. An infra red filter is used to remove heat from
the light, providing only cool, effective light into the
process. A high output, low voltage bulb and reflector
deliver the maximum amount of light into the vessel.
Light is guided fiber-optically through the light pipe
into the process or pressure area. All Canty light
pipes feature our high pressure, high temperature
fused glass seal for maximum safety. A variety of
couplings are available.
Ph: (716) 625 4227
Ph: + 353 (01) 882 9621
Fax: (716) 625 4228
Fax: +353 (01) 882 9622
www.jmcanty.com
Document P/N: TA10835-1 Rev. 2
Reading Office
Aberdeen Office
Cutbush Park, Danehill, Lower Earley,
Reading, Berkshire. RG6 4UT. UK.
Tel: +44 (0)118 9311188
Email: info@able.co.uk
Unit 6 Airside Business Park, Kirkhill Industrial Estate,
Dyce, Aberdeen. AB21 0GT. UK.
Tel: +44 (0)1224 725999
Email: ab@able.co.uk
Internet: www.able.co.uk
e-procurement: www.247able.com
Registered in England No: 01851002
VAT No: GB 417 2481 61
1
Typical Dimensions
Ø5.5” TYP.
[140mm]
1/2” NPT
WIRE INLET,
TYP.
8.7” TYP.
[221mm]
NPT
For fiber optic flexible bundle
models reference datasheet
P/N TA10836-1.
TRI-CLAMP®
FLANGE
HOW TO ORDER: Select the appropriate symbols and build a part number as shown.
Recommended model options are shown in bold.
HLUS45S0
EXAMPLE:
Light Source Selection
Insertion Length*
Integral Transformer Models. Separate Power Supply Not Required
0 - None
1 - 2” INS
2 - 6” INS
3 - 3” INS
4 - 4” INS
HL - 80 W, 120V AC input direct to light. EXP rating.
EK - 80 W, 230V AC input direct to light. FP rating.
NH - 80 W, 120V AC input direct to light. WP rating.
N1 - 80 W, 230V AC input direct to light. IP rating.
NW- 50 W, 120V AC input direct to light. EXP rating.
NZ - 50 W, 230V AC input direct to light. FP rating.
NV - 50 W, 120V AC input direct to light. WP rating.
NY - 50 W, 230V AC input direct to light. IP rating.
5
6
7
8
A
-
5” INS
7” INS
8” INS
9” INS
10” INS
B - 11” INS
C - 12” INS
D - 13” INS
E - 14” INS
* Insertions Are Not Available on Glass Wetted Models
Non Wetted Material
C - CS, 150#ANSI D - CS, 300# ANSI
S - SS, 150#ANSI E - SS, 300# ANSI
A - CS, 10 BAR
Z - CS, 16 BAR
B - SS. 10 BAR
Y - SS, 16 BAR
0 - No Retaining Flange Required/Applicable. Select
Separate Transformer / Power Supply
N6 - 80 W, EXP rated light with separate power supply.
N2 - 80 W, FP rated light with separate power supply.
N8 - 80 W, WP rated light with separate power supply.
N9 - 80 W, IP rated light with separate power supply.
N5 - 50 W, EXP rated light with separate power supply.
NG - 50 W, FP rated light with separate power supply.
N4 - 50 W, WP rated light with separate power supply.
N7 - 50 W, IP rated light with separate power supply.
for all Tri-Clamp® Connections.
Mounting Connection
1 - 1” NPT
9 - 1.5” Flanged, 150# /DN40 PN10
3 - 2” Flanged, 150# /DN50 PN10
4 - 3” Flanged, 150# /DN80 PN10
5 - 4” Flanged, 150# /DN100 PN10
6 - 6” Flanged, 150# /DN150 PN10 (Insertion only)
Z - 1.5” Flanged, 300# /DN40 PN16
A - 2” Flanged, 300# /DN50 PN16
B - 3” Flanged, 300# /DN80 PN16
C - 4” Flanged, 300# /DN100 PN16
D - 6” Flanged, 300# /DN150 PN16 (Insertion only)
Power Supplies
Weather proof Light Options
(N8/N9) HYL 80 WP/IP Lights with Separate PSU
9 - NEMA 4X / IP66 power supply with switch. User supplies 120V AC (WP Models)
or 230V AC (IP Models).
5 - NEMA unrated / IP00 bare transformer. User supplies 120V AC.
0 - NEMA unrated / IP00 bare transformer. User supplies 230V AC.
(N4/N7) HYL 50 WP/IP Lights with Separate PSU
5 - NEMA unrated / IP00 bare transformer. User supplies 120V AC.
6 - No Transformer. Customer supplies 12V AC or DC source, 50W min.
7 - NEMA unrated / IP00 bare transformer. User supplies 230V AC.
E - 1” or 1.5” Tri-Clamp®
F - 2” Tri-Clamp®
Y - 2.5” Tri-Clamp®
(NV/NY) HYL 50 WP/IP Lights with Integral Transformer
U - Customer supplies ON/OFF switch.
G - 3” Tri-Clamp®
(NH/N1) HYL 80 Toroidal WP/IP Lights with Integral Transformer
U - Customer supplies ON/OFF switch.
C - NEMA 4X / IP66 enclosure with switch. 120V AC input.
R - NEMA 4X / IP66 enclosure with switch. 230V AC input.
J - 2” 150#/ DN50 PN10 Glass Wetted Flange
K - 3” 150#/ DN80 PN10 Glass Wetted Flange
L - 4” 150#/ DN100 PN10 Glass Wetted Flange
M - 6” 150#/ DN150 PN10 Glass Wetted Flange
H - 4” Tri-Clamp®
Explosion proof / Flame proof Light Options
Many Additional Sizes Available. Consult
(N6/N2) HYL 80 EXP/FP Lights with Separate PSU
J - Explosion proof power supply. 120V AC input. See note 5.
5 - NEMA unrated / IP00 bare transformer. User supplies 120V AC.
N - NEMA unrated / IP00 bare transformer. User supplies 230V AC.
Beam Output Options
(HL/EK) HYL 80 Toroidal EXP/FP Lights with Integral Transformer
3 - Wide Beam High Temp. (90°) cone
4 - Normal Beam High Temp. (30°) cone
U - Customer supplies ON/OFF switch.
(N5/NG) HYL 50 EXP/FP Lights with Separate PSU
5 - NEMA unrated / IP00 bare transformer. User supplies 120V AC.
N - NEMA unrated / IP00 bare transformer. User supplies 230V AC.
H - No Transformer. Customer supplies 12V AC or DC source, 50W min.
(NW/NZ) HYL 50 EXP/FP Lights with Integral Transformer
U - Customer supplies ON/OFF switch.
Wetted Materials
S - 316L SS*
WP = Weather Proof
EXP = Explosion Proof
FP = Flame Proof
IP = Ingress Protection
Notes :
1) Some options are not available on all models.
2) Vessel lighting diameter, depth specifications provided are a general guideline for stainless steel
tanks with 30° normal beam conical light output option. For blue glass lined reactors, which will absorb
visible wavelengths of light, a derating factor of 0.7 is recommended.
3) All Explosion Proof lights are rated for use in Class I, Div. 1, Groups B, C and D, Class II,
Div. 1, Groups E, F & G as well as NEMA 4 locations. Power supply rating vary with model.
4) All Flame Proof lights are approved for use in EExd II C T6 and IP 66 locations.
5) Explosion proof power supply enclosures are rated use in Class I, Div. 1, Groups C and D, Class II, Div. 1,
Groups E, F & G locations.
CANTY
JM Canty Inc
| Buffalo, NY USA |
JM Canty Intl Ltd | Dublin, Ireland
|
D - Hastelloy® C276 or equal
E - Hastelloy® C-22® or equal
F - Boroplus (Glass Wetted)**
*Canty Reserves the right to upgrade to Hastelloy®
C-family of alloys or equal at their own cost.
** Not available on all models
All registered trademarks are the property of their
respective owners.
Ph: (716) 625 4227
Ph: + 353 (01) 882 9621
| Fax: (716) 625 4228
| Fax: +353 (01) 882 9622
www.jmcanty.com
Document P/N: TA10835-1 Rev.
2
Reading Office
Aberdeen
Office
Cutbush Park, Danehill, Lower Earley,
Reading, Berkshire. RG6 4UT. UK.
Tel: +44 (0)118 9311188
Email: info@able.co.uk
Unit 6 Airside Business Park, Kirkhill Industrial Estate,
Dyce, Aberdeen. AB21 0GT. UK.
Tel: +44 (0)1224 725999
Email: ab@able.co.uk
Internet: www.able.co.uk
e-procurement: www.247able.com
Registered in England No: 01851002
VAT No: GB 417 2481 61
2