10 - ENERGY MANAGEMENT
Multifunction Meters
Digiware Plug & Play Metering
Split Core Current Transformers
TCA & TCB Current Transformers
Metering
Digital kWh Meters (single phase)332
Electromechanical kWh Meters (single phase)332
Digital kWh Meters (three phase)
333
Countis ECi Pulse Collector
335
Multifunction Digital Meters336
Communications Interfaces343
Digiware Plug & Play Metering
Digiware Metering System345
Digiware Current Sensors348
Digiware Cables350
Diris B-30 Multi-function Meter351
Diris G Modbus / Ethernet Gateway352
Split Core Current Transformers
353
Current Transformers
TCB18 & TCB22 Series Current Transformers (3 in 1)354
TCA & TCB Series Current Transformers355
CTME Series Measurement Current Transformers356
Dimensions - CTME Series Current Transformers357
Metering Test Block
ENERGY
MANAGEMENT
Ammeter with selector switch
Panel Mounting Meters
AC Moving Iron Ammeters and Voltmeters328
Maximum Demand Ammeters 329
Combined Maximum Demand Ammeters329
Pointer Type Frequency Meters
329
AC Moving Iron Ammeters and Voltmeters with selector switch329
Hour Run Counter
330
Connection Diagrams and Dimensions331
10
358
TCB18 & TCB22 Current Transformers
Metering Test Block
IPD GROUP LIMITED
Phone: 1300 556 601
www.ipdgroup.com.au
Product Catalogue v-15 327
PANEL MOUNTING METERS
AC MOVING IRON VOLTMETERS DIRECT CONNECT WITH SCALE
Features:
-Cases IEC-473 non-combustible dust & splash proof.
-Resilient jewel pivot bearings, vibration
max 2.5g, shock to 15g.
-Insulation tested 2kV/1min 50Hz.
-Operating temperature: -25°C to 40°C.
-Designed, manufactured and tested to
IEC60051:1997.
Bezel
Description
Scale Size (mm)
Voltmeter direct connected 0-300VAC 72 x 72
class 1.5 scale 90 degree
96 x 96
0-500VAC 72 x 72
96 x 96
Scale included.
Part No.
EC72-300VAC
EC96-300VAC
EC72-500VAC
EC96-500VAC
Ammeters CURRENT TRANSFORMER OPERATED
WITH 2 x OVER-SCALE
Bezel
Description
Size (mm)
Part No.
Suitable for 5A CT secondary
72 x 72
A72/*-2P
class 1.5 scale 90 deg. 2P
96 x 96
A96/*-2P
Scale included.*Please specify CT primary current value.
Ammeters CURRENT TRANSFORMER OPERATED
WITH 6 x OVER-SCALE
EC72-500VAC
Bezel
Description
Size (mm)
Part No.
Suitable for 5A CT secondary
72 x 72
A72/*-6P
class 1.5 scale 90 deg. 6P
96 x 96
A96/*-6P
Scale included.*Please specify CT primary value.
Ammeters DIRECT CONNECT
WITH 6 x OVER-SCALE
Bezel
Description
Scale Size (mm)
0 - 5 Amp 72 x 72
Ammeter direct connect
0 - 5 Amp 96 x 96
class 1.5 scale 90 deg. 6P 0 - 10 Amp 72 x 72
0 - 20 Amp 72 x 72
0 - 30 Amp 72 x 72
Scale included.
A72/100-2P
Part No.
EC72-5AAC6P
EC96-5AAC6P
EC72-10AAC6P
EC72-20AAC6P
EC72-30AAC6P
Note: For DIN rail mounting meters, digital ammeters and voltmeters, please
consult IPD.
A96/100-2P
PART NO. CREATION
A 72 / 100 - 2P
Ammeter
Size
2 x overcurrent
scale
Primary current
value of CT
IPD GROUP LIMITED
328 Product Catalogue v-15
Phone: 1300 556 601
www.ipdgroup.com.au
PANEL MOUNTING METERS
Bimetallic Maximum Demand Ammeters AC
Inertia Time: 15 Minutes
Bezel
Description
Size (mm)
Part No.
Max. demand (5A CT secondary)
72 x 72
MD72/*
class 3.0 scale 90 deg. 1.2P
96 x 96
MD96/*
Scale included.*Please specify CT primary current value.
MD72/3000
Combined: Bimetallic Maximum Demand +
Moving Iron Ammeters AC
Bezel
Description
Size (mm)
Part No.
MD (5A CT secondary) class 3.0 1.2P
72 x 72
CMD72/*
15 min + ammeter 5A class 1.5
96 x 96
CMD96/*
90 deg. 2P
Scale included.*Please specify CT primary current value.
CMD96/*
Pointer Type Frequency Meters
Description
Pointer type frequency meter
class 1.0 scale 90 deg.
Scale included.
Bezel
Size (mm)
72 x 72
72 x 72
Part No.
HC72-240V45-55
HC72-415V45-55
ENERGY
MANAGEMENT
HC72-240V45-55
10
AC MOVING IRON VOLTMETER
Bezel
Description
Size (mm)
Part No.
Voltmeter with selector switch
72 x 72 EC72FN111+N500V
(6 position w/o off)
class 1.5 scale 90 deg. 3/4 wire
96 x 96 EC96FN111+N500V
Scale included.
EC72FN111+N500V
PART NO. CREATION
MD 72 / 3000
Maximum
Demand
Primary current
value of CT
Size
IPD GROUP LIMITED
Phone: 1300 556 601
www.ipdgroup.com.au
Product Catalogue v-15 329
PANEL MOUNTING METERS
AC MOVING IRON AMMETERS
EC72FA600/5AAC2P
PART NO. CREATION
MD 72 / 3000
Maximum
Demand
Primary current
value of CT
Size
Fitted with
Description
Scale (A)
Part No.
Ammeter with selector switch 0-5EC72FA5/5AAC2P
(3 position w/o off) suitable
0-50EC72FA50/5AAC2P
for 5A CT secondary, class 1.5
0-100
EC72FA100/5AAC2P
scale 90 deg. 2x over-scale,
0-200EC72FA200/5AAC2P
suit 3/ wire network,
40-250EC72FA250/5AAC2P
scale included
0-400EC72FA400/5AAC2P
0-600EC72FA600/5AAC2P
0-800EC72FA800/5AAC2P
Bezel
0-1000EC72FA1000/5AAC2P
72 x 72mm
0-1200EC72FA1200/5AAC2P
0-1500EC72FA1500/5AAC2P
0-1600EC72FA1600/5AAC2P
0-5EC96FA5/5AAC2P
0-50EC96FA50/5AAC2P
0-150EC96FA150/5AAC2P
Bezel
0-250EC96FA250/5AAC2P
96 x 96mm
0-400EC96FA400/5AAC2P
0-600EC96FA600/5AAC2P
0-800EC96FA800/5AAC2P
0-1000EC96FA1000/5AAC2P
0-1200EC96FA1200/5AAC2P
0-1250EC96FA1250/5AAC2P
0-1600 EC96FA1600/5AAC2P
*Other ratings available on request.
HOUR RUN COUNTERS (Non-Resetable)
PANEL MOUNT
Bezel
Size
Description
Scale
(mm)
Part No.
240V AC/DC
Resets
CH48AC/DC240V
110V AC/DC
at
48 x 48CH48AC/DC110V
24V AC/DC
99999.99
CH48AC/DC24V
CH48AC/DC240V
DIN RAIL MOUNT
Width in
17.5mm
Description
Scale Modules
Part No.
230V AC
Resets at
2
DINHOUR COUNTER
IP 65
99999.99
DINHOUR COUNTER
IPD GROUP LIMITED
330 Product Catalogue v-15
Phone: 1300 556 601
www.ipdgroup.com.au
PANEL MOUNTING METERS
Connection Diagrams
ENERGY
MANAGEMENT
(.../5A CT Connection)
10
Dimensions in mm and inches
Model
Unit
A
B
C
D
E
F
96mm96 9290
5.5
6543
96
In
3.74 3.62 3.54 0.22 2.56 1.69
72mm72 6866
5.5
6543
72
In
2.83 2.68 2.60 0.22 2.56 1.69
48mm48 4442
5.5
6543
48
In
1.89 1.73 1.65 0.22 2.56 1.69
B for the size of panel cut-out.
IPD GROUP LIMITED
Phone: 1300 556 601
www.ipdgroup.com.au
Product Catalogue v-15 331
DIGITAL KILOWATT HOUR METERS
DIRECT CONNECT - SINGLE PHASE DIGITAL kWh METERS
Class 1 Accuracy
COUNTIS E00
Features:
- Voltage measurement 230VAC.
- 100Wh, 100ms pulse output.
- Total & Partial kWh reading.
- IEC 62053-22 / 23 & IEC 2053-31.
- Din Rail Mount.
Description
Part No. 32 Amp Direct Connect 230V AC
Width 17.5mm modules: 1 48503019
Pulse output
Aux. supply from monitoring supply
Reading: Total kWh
Metrological LED
COUNTIS E03
32 Amp Direct Connect 230V AC
Width 17.5mm modules: 1 48503029
RS485 JBUS/MODBUS communication
Aux. supply from monitoring supply
Reading: Total kWh
Metrological LED
COUNTIS E00
COUNTIS E10
COUNTIS E03
63 Amp Direct Connect 230V AC
Width 17.5mm modules: 3 48503000
Pulse output
Aux. supply from monitoring supply
Reading: Total / Partial kWh
Metrological LED
COUNTIS E13
80 Amp Direct Connect 230V AC
Width 17.5mm modules: 3 48503031
RS485 JBUS/MODBUS communication
Aux. supply from monitoring supply
Reading: Total / Partial kWh
Metrological LED
COUNTIS E10
COUNTIS E13
Features:
-Pulse output.
-DIN rail mount.
-Numeric display.
ELECTRO MECHANICAL kWh METERS - CLASS1
ORBIS CONTAX25
Description
Part No.
25 Amp direct connect meter 230V AC
width 17.5mm modules: 1CONTAX2511S0-230
ORBIS CONTAX65
Description
Part No.
65 Amp direct connect meter 230V AC
width 17.5mm modules: 2CONTAX6521S0-230
CONTAX2511S0-230
CONTAX6521S0-230
IPD GROUP LIMITED
332 Product Catalogue v-15
Phone: 1300 556 601
www.ipdgroup.com.au
DIGITAL KILOWATT HOUR METERS
DIRECT CONNECT - THREE PHASE DIGITAL kWh METERS
Class 1 Accuracy
COUNTIS E20
Features:
- Voltage measurement range 230 - 400VAC.
- 100Wh, 100ms pulse output.
- RS485 JBUS/MODBUS communication.
- Total & Partial kWh reading.
- Wrong connection indication.
- Protection against Phase / Neutral reversal.
- IEC 62053-21 / 23 & IEC 60253-31.
- Din Rail Mount.
Description
Part No. 63 Amp Direct Connect 400V AC
Width 17.5mm modules: 4 48503003
Pulse output
Aux. supply from monitoring supply
Reading: Total / Partial kWh
Metrological LED
COUNTIS E23 (Multi-Function)*
63 Amp Direct Connect 400V AC
Width 17.5mm modules: 4 48503035
RS485 JBUS/MODBUS communication
Aux. supply from monitoring supply
Reading: Total / Partial kWh
Metrological LED
COUNTIS E20
COUNTIS E30
100 Amp Direct Connect 400V AC
Width 17.5mm modules: 7 48503005
Pulse output
Aux. supply from monitoring supply
Reading: Total / Partial kWh
Metrological LED
100 Amp Direct Connect 400V AC
Width 17.5mm modules: 7 48503012
Four tariffs
RS485 JBUS/MODBUS communication
Aux. supply from monitoring supply
Reading: Total / Partial kWh
Metrological LED
ENERGY
MANAGEMENT
COUNTIS E33 (Multi-Function)*
COUNTIS E23
10
COUNTIS E63 (Multi-Function)*
COUNTIS E30
100 Amp Direct Connect 400V AC
Width 17.5mm modules: 7 48503016
Three-phase or Single-phase 3 x 1 Phase, 1 Shared Neutral
RS485 JBUS/MODBUS communication
Aux. supply from monitoring supply
Reading: Total / Partial kWh
Metrological LED
Four tariff
* The following parameters are available via RS485:
3I, In, 3V, 3U, 3P, ∑P, 3Q, ∑Q, 3S, ∑S, ∑PF.
COUNTIS E33/E63
IPD GROUP LIMITED
Phone: 1300 556 601
www.ipdgroup.com.au
Product Catalogue v-15 333
DIGITAL KILOWATT HOUR METERS
CT CONNECT - THREE PHASE DIGITAL kWh METERS
Class 1 Accuracy
COUNTIS E40
Features:
-Measurement range 230 - 400VAC.
- 100Wh, 100ms pulse output.
- RS485 JBUS/MODBUS communication.
- Wrong connection indication.
- Protection against phase / neutral reversal.
- IEC 62053-22 / 23 & IEC 62053-31.
- Din-Rail & Panel Mount.
Description
Part No. …/5 Amp CT Connect 184 - 400V AC
Width 17.5mm modules: 4 48503008
Class 1 Accuracy
Pulse output
Aux. supply from monitoring supply
Reading: Total / Partial kWh
Reading: Total / Partial kvarh
Metrological LED
COUNTIS
E43 (Multi-Function)*
COUNTIS E40/E43
…/5 Amp CT Connect 184 - 400V AC
Width 17.5mm modules: 4 48503017
Four tariffs
Class 1 Accuracy
RS485 JBUS/MODBUS communication
Aux. supply from monitoring supply
Reading: Total / Partial kWh
Reading: Total / Partial kvarh
Metrological LED
ACCESSORIES
- E40/E43
Sealable cover
* The following parameters are available via RS485:
3I, In, 3V, 3U, 3P, ∑P, 3Q, ∑Q, 3S, ∑S, ∑PF.
Note:
For current transformers (CT’s) refer to pages 353 - 357.
For CT shorting link terminals refer to page 442.
IPD GROUP LIMITED
334 Product Catalogue v-15
Phone: 1300 556 601
www.ipdgroup.com.au
4850304U
PULSE METERING
COUNTIS ECi2 PULSE COLLECTOR
Features:
-LCD display for direct reading.
-Aux. supply voltage: 110 - 400V AC.
- Digital inputs: voltage 10 - 30V DC.
-Digital inputs: current 2 - 15mA.
- Analogue inputs: current 25mA.
- IEC 62053-31 class B.
Description
Part No. Pulse Collector without analogue inputs
RS485 JBUS/MODBUS communication
48530000
7 Digits Inputs
Aux supply: 110 - 400VAC
Internal memory
Dimensions: L73 x W90 x H67mm
COUNTIS
ECi3 PULSE COLLECTOR
Pulse Collector with 2 analogue inputs
RS485 JBUS/MODBUS communication
48530001
7 Digits Inputs
Aux supply: 110 - 400VAC
Internal memory
Dimensions: L73 x W90 x H67mm
COUNTIS ECi2
APPLICATION
COUNTIS ECi3
ENERGY
MANAGEMENT
The pulse collector enables pulses from electricity meters, water, gas and
compressed air metersor analogue sensors to be registered and stored.
All data i.e. energy meters kilowatt hours and load curves can be centalised via
RS485, JBUS/MODBUS communication.
10
kWh pulse outputs
Gas
Water
7 inputs to collect pulses from different energy meters (water, air, gas, electricity...)
1 x Digital Output
2 x Analogue Inputs
(0/4 - 20mA / 0 - 10Vdc)
Memory
To computer via: RS485 - JBUS/MODBUS
IPD GROUP LIMITED
Phone: 1300 556 601
www.ipdgroup.com.au
Product Catalogue v-15 335
Diris® A / MULTIS THREE - PHASE MULTIFUNCTION METERS
Energy Management and Network analysing meters.
The Diris multifunction meters have a built-in electronic component (ASIC).
Developed specifically by SOCOMEC for the measurement functions to achieve very high
measurement accuracy.
Energy Accuracy:
- Active energy, class 0.5S to IEC 62053-22.
- Reactive energy, class 2 to IEC 62053.23.
The Socomec Diris A meters functions include;
- Metering
- Measuring
- Monitoring
- Analysing
- Communicating
The add-on modules can be used to upgrade the product functions at any time for measuring,
reporting and communications functions.
Diris® A / Multis Multifunction Meters
Characteristics
L40
A10A17 A20A40A41A60 Application network (3P, 3P+N and single-phase)
LV/HV
LV LV/HV LV LV/HVLV/HVLV/HV
Mounting PanelDIN rail
Panel PanelPanelPanelPanel
Current (3I, In)
•
•
•
•
•
•
•
4th CT for measuring neutral on networks with
harmonics disturbances
•
Harmonic distortion rate on current and voltage
intergrate (THD 3I, 3V, 3U)
51st 31st
51st 63rd
63rd
63rd
Accuracy: Current and Voltage 1%
0.2%
0.5%
0.2%
0.2%
0.2%
0.2%
Accuracy: Active energy Class 1
0.5S
1
0.5S
0.5S
0.5S
0.5S
Accuracy: Reactive energy Class 2
2
2
2
2
2
2
CT Secondary earthed
yes yesyes yesyesyesyes
Power factor -instantaneous 3PF , ∑PF
•
•
•
•
•
•
•
Active, reactive and apparent energy on 4 quadrants
(kWh, kvarh, kVAh)
•
•
•
•
RS485 JBUS / MODBUS Protocol •
•
•
•
•
•
•
Ethernet connection with Modbus TCP or JBUS / MODBUS
over TCP protocol
•
•
•
Ethernet connection with RS485 gateway with Modbus TCP or
JBUS / MODBUS RTU over TCP protocol
•
•
•
Temperature measurement internal, extrnal via 3 PT100 sensors
•
•
•
Output pulse configurable
2 11 1222
Digital Input
•
•
•
•
Analogue outputs (plug-in module)
•
•
•
Current & Voltage imbalance displayed
•
Stores load curves (50 days) for active, reactive & apparent power.
•
Detects & stores the last 40 events for overvoltage, voltage dips,
voltage outage & current
•
Auxiliary supply AC
190…260V 200…277V220...277V 110…400V110…400V110…400V110…400V
Dimensions W x H x D (mm)
72x90x64
72x90x64 72x72x50
96x96x60 96x96x60 96x96x60 96x96x60
IPD GROUP LIMITED
336 Product Catalogue v-15
Phone: 1300 556 601
www.ipdgroup.com.au
Diris® A10 MULTIFUNCTION METER
DIRIS A10
Features:
- Accuracy class 0.5S to IEC62053-22.
- Ambient temperature indication.
- Diagnose and fix CT connection errors.
- Suitable for LV installations.
- DIN rail mount: 4 modules wide.
- Large backlit LCD display.
- Two-rate tariff function.
Description
Part No.
DIRIS A10 multifunction meter with pulse output
48250010
DIRIS A10 multifunction meter with RS485 JBUS/Modbus
communication and pulse output
48250011
Auxiliary supply: 200 - 277V AC.
Accuracy class 0.5S to IEC 62053-22.
Total harmonic distortion up to row 51.
STANDARD FUNCTIONS
CONNECTION
CT .../5A METERING
Active energy: + kWh.
Reactive energy: + kvarh.
Hours.
DIRIS A10
INSTANTANEOUS RMS VALUES
Current (3I, In).
Frequency (F).
Active, reactive and apparent power, per phase and total
(±3p, ±3Q, 3S, ±∑P, ±∑Q, ∑S) .
Power factor, per phase and total (3PF, ∑PF).
POWER QUALITY MEASUREMENTS
Harmonic distortion rate on current and voltage integrated up to 51st
harmonic (THD 3I, 3V, 3U).
1 Pulse OUTPUT
Pulse configurable (type, weight, time) in kWh,or kvarh OR
monitoring 3I, In,3V, 3U, F, ∑P, ∑Q, ∑S, ∑PF, THD 3I, 3V, 3U OR
command through RS485 (48250011 only).
ENERGY
MANAGEMENT
MAXIMUM VALUES
Current (3I, In).
10
ENERGY MEASUREMENT PRECISION
Class 0.5s - IEC 62053-22 (Active energy).
Class 2 - IEC 62053-23 (Reactive energy).
Note:
For current transformers (CT’s) refer to pages 353 - 357.
For CT shorting link terminals refer to page 442.
IPD GROUP LIMITED
Phone: 1300 556 601
www.ipdgroup.com.au
Product Catalogue v-15 337
Diris® A17 MULTIFUNCTION METER
DIRIS A17
Features:
- Accuracy class 1 to IEC62053-21.
- Panel mount: 72 x 72, IP52 (front panel).
- Suitable for LV/HV installations.
- Modbus RTU RS485 communication.
- Current Transformers secondary ratio .../5A
or .../1A.
- 1 digital input.
-1 digital output (pulse output or alarm or
remote command).
Description
DIRIS A17 multifunction meter with RS485
JBUS/MODBUS communication
DIRIS A17 multifunction meter with RS485 JBUS/Modbus
communication and total harmonic distortion (THD)
Auxiliary supply: 190 - 260V AC.
Accuracy class 1.
Part No.
48250102
48250103
STANDARD FUNCTIONS
CONNECTION
CT .../5A or CT .../1A 72 x 72mm
Panel mount
METERING
Active energy: kWh.
Reactive energy: kvarh.
INSTANTANEOUS RMS VALUES
Voltage (3V, 3U).
Current (3I, In).
Frequency (F).
Active, reactive and apparent power, per phase and total
(3p, 3Q, 3S, ∑P, ∑Q, ∑S) .
Power factor, per phase and total (3PF, ∑PF).
DIRIS A17
MAXIMUM VALUES
Maximum average: ∑P, ∑Q, ∑S.
1 Pulse OUTPUT
Pulse configurable (type, weight, time) in kWh,or kvarh OR
monitoring 3I, In,P, Q, S, PF, THDI, THDU, THDV OR
command through RS485.
1 Pulse INPUT
Monitoring remote device activation or counting water/gas
energy pulses.
Operation voltage: 8...30V DC.
ENERGY MEASUREMENT PRECISION
Class 1 - IEC 62053-21 (Active energy).
Class 2 - IEC 62053-23 (Reactive energy).
Note:
For current transformers (CT’s) refer to pages 353 - 357.
For CT shorting link terminals refer to page 442.
IPD GROUP LIMITED
338 Product Catalogue v-15
Phone: 1300 556 601
www.ipdgroup.com.au
Diris® A20 MULTIFUNCTION METER
DIRIS A20
Features:
- Accuracy class 0.5S to IEC62053-22.
-Panel mount: 96 x 96, IP40 (front panel).
-Large easy to read backlit LCD display.
-4 direct access keys - simple to operate.
-Facility to add up to 2 plug-in modules.
-Diagnose and fix CT connection errors.
Description
Part No.
DIRIS A20 multifunction meter, base unit
Auxiliary supply: 110-400V AC, 120-350V DC
48250200
Accuracy class 0.5S to IEC62053-22.
Total harmonic distortion up to row 51.
PLUG-IN MODULES
Description
Part No.
Output 1 digital output for kWh or kvarh pulses OR
alarm OR command through RS485 48250080
Communication
RS485 communication module with
JBUS/MODBUS protocol
48250082
DIRIS A20
STANDARD FUNCTIONS
CONNECTION
CT .../5A INSTANTANEOUS RMS VALUES
Current (3I, In).
Frequency (F).
Active, reactive and apparent power, per phase and total
(±3p, ±3Q, 3S, ±∑P, ±∑Q, ∑S).
Power factor, per phase and total (3PF, ∑PF).
ENERGY
MANAGEMENT
METERING
Active energy: + kWh.
Reactive energy: + kvarh.
Hours.
10
MAXIMUM VALUES
Current (3I, In).
POWER QUALITY MEASUREMENTS
Harmonic distortion rate on current and voltage integrated up to 51st
harmonic (THD 3I, 3V, 3U).
ENERGY MEASUREMENT PRECISION
Class 0.5s - IEC 62053-22 (Active energy).
Class 2 - IEC 62053-23 (Reactive energy).
Note:
For current transformers (CT’s) refer to pages 353 - 357.
For CT shorting link terminals refer to page 442.
IPD GROUP LIMITED
Phone: 1300 556 601
www.ipdgroup.com.au
Product Catalogue v-15 339
Diris® A40/A41 MULTIFUNCTION METERS
DIRIS A40
Features:
- Accuracy class 0.5S to IEC62053-22.
- .../1A or .../5A CT connection.
- Panel Mount; 96 x 96mm, IP40 (front panel).
- Suitable for LV and HV installations.
- Large easy to read backlit LCD display.
- 6 direct access keys - simple to operate.
- Facility to add up to 4 plug-in modules.
- Diagnose and fix CT connection errors.
Description
Part No.
DIRIS A40 multifunction meter, base unit
Auxiliary supply: 110-400V AC, 120-350V DC
48250201
DIRIS A40 multifunction meter, base unit
Auxiliary supply: 12-48V DC
48251201
Accuracy class 0.5S to IEC62053-22
Total harmonic distortion up to row 63
DIRIS A41 (4 CT Input - Neutral Measurement)
Description
Part No.
DIRIS A41 multifunction meter, base unit
Auxilary supply: 110-400V AC, 120-350V DC
48250202
DIRIS A41 multifunction meter, base unit
Auxilary supply: 12-48V DC
48251202
Accuracy class 0.5S to IEC62053-22
Total harmonic distortion up to row 63
PLUG-IN MODULES (A40/A41)
Description
Part No.
DIRIS A40 / 41
PULSE OUTPUTS
2 configurable pulse outputs
48250090
COMMUNICATION
RS485 communication module JBUS/MODBUS
48250092
Direct ethernet connection
48250203
Ethernet with RS485 gateway 48250204
RS485 PROFIBUS DP communication
48250205
ANALOGUE OUTPUTS
2 configurable outputs on 3I, In, 3V, F,
±∑P, ∑Q, ∑S and ∑PF
48250093
2 INPUTS - 2 OUTPUTS
2 to 6 outputs for monitoring of 3I, In, 3V, F,
±∑P, ∑Q, ∑S and ∑PF
48250094
MEMORY
Storing P+, P-,Q+,Q- for up to 62 days.
Storing min/max instantaneous values for 3U, In, 3V,
F,±∑P, ∑Q, ∑S, THD3U, THD3V, THD3I, THDIn.
Storing last 10 time-stamped alarms, voltage dips,
surges and outages.
48250097
TEMPERATURE
Measure 1 internal and 3 external temperatures. PT100 sensors are required for external temperature measurements. 48250206
Note:
For current transformers (CT’s) refer to pages 353 - 357.
For CT shorting link terminals refer to page 442.
IPD GROUP LIMITED
340 Product Catalogue v-15
Phone: 1300 556 601
www.ipdgroup.com.au
Diris® A60 MULTIFUNCTION METER
Energy quality and event detection.
Sag, swell, outages and overcurrent.
DIRIS A60
Features:
- Accuracy class 0.5S to IEC62053-22.
- .../1A or .../5A CT connection.
- Panel Mount; 96 x 96mm, IP40 (front panel).
- Suitable for LV and HV installations.
- Large easy to read backlit LCD display.
- 6 direct access keys - simple to operate.
- Facility to add up to 3 plug-in modules.
- Diagnose and fix CT connection errors.
DIRIS A60
Description
Part No.
DIRIS A60 multifunction meter base.
Auxiliary supply: 110-400V AC, 120-350V DC.
48250207
Accuracy class 0.5S to IEC62053-22.
Total harmonic distortion up to row 63.
Memory module fitted as standard.
Storing P+, P-,Q+,Q- for up to 62 days.
Storing min/max instantaneous values for 3U, In, 3V,
F,±∑P, ∑Q, ∑S, THD3U, THD3V, THD3I, THDIn.
Storing last 10 time-stamped alarms, voltage dips, surges and outages.
In addition to the Diris A40 the Diris A60
- Shows the current and voltage imbalance.
- Shows the tangent phi (Tan ∫ φ ) = P/Q.
- Stores the load curves (50 days) with an interval of 10 minutes for:
- Active, reactive and apparent power.
- Detects and stores the last 40 events:
- Overvoltage.
- Voltage dips.
- Voltage outage.
- Current.
PLUG-IN MODULES
Description
Part No.
PULSE OUTPUTS
2 configurable pulse outputs
48250090
ANALOGUE OUTPUTS
2 configurable outputs on 3I, In, 3V, F,
±∑P, ∑Q, ∑S and ∑PF
48250093
ENERGY
MANAGEMENT
COMMUNICATION
RS485 communication module JBUS/MODBUS
48250092
Direct ethernet connection
48250203
Ethernet with RS485 gateway 48250204
RS485 PROFIBUS DP communication
48250205
10
2 INPUTS - 2 OUTPUTS
2 to 6 outputs for monitoring of 3I, In, 3V, F,
±∑P, ∑Q, ∑S and ∑PF
48250094
TEMPERATURE
Measure 1 internal and 3 external temperatures. PT100 sensors are required
for external temperature measurements. 48250206
Note:
For current transformers (CT’s) refer to pages 353 - 357.
For CT shorting link terminals refer to page 442.
IPD GROUP LIMITED
Phone: 1300 556 601
www.ipdgroup.com.au
Product Catalogue v-15 341
MULTIS L40 MULTIFUNCTION METER
MULTIS L40
Features:
- Accuracy class 1.
- Panel mount: 96 x 96, IP40 (front panel).
- Suitable for LV/HV installations.
- Modbus RTU RS485 communication.
- Current Transformers secondary ratio .../5A
or .../1A.
- 2 digital inputs.
-2 energy pulse outputs.
Description
MULTIS L40 multifunction meter with RS485
JBUS/MODBUS communication and pulse output
Part No.
192J9110
Auxiliary supply: 190 - 260V AC.
Accuracy class 1.
STANDARD FUNCTIONS
CONNECTION
CT .../5A or CT .../1A METERING
Active energy: kWh.
Reactive energy: kvarh.
MULTIS L40
INSTANTANEOUS RMS VALUES
Voltage (3V, 3U).
Current (3I, In).
Frequency (F).
Active, reactive and apparent power, per phase and total
(3P, 3Q, 3S, ∑P, ∑Q, ∑S).
Power factor, per phase and total (3PF, ∑PF).
MINIMUM / MAXIMUM VALUES
Voltage (3V, 3U).
Current (3I).
Active, reactive and apparent power, per phase and total
Max. Demand (3I, 3P, 3Q, 3S, ∑P, ∑Q, ∑S).
DIGITAL PULSE OUTPUT
2 energy pulse outputs (5...24VDC operation voltage).
Pulse configurable.
Pulse duration 100ms max.
DIGITAL PULSE INPUT
2 inputs for monitoring remote device activation or counting
water/gas energy pulses.
Operation voltage: 12...48V AC/DC.
Note:
For current transformers (CT’s) refer to pages 353 - 357.
For CT shorting link terminals refer to page 442.
IPD GROUP LIMITED
342 Product Catalogue v-15
Phone: 1300 556 601
www.ipdgroup.com.au
COMMUNICATION INTERFACES
Connecting RS485 links
Function
Part No. RS232 / RS485 interface
Signal conversion from RS485 to RS232.
48990100
Up to 31 devices can be connected over a distance of 1200m at 9600 bauds.
RS232/RS485 INTERFACE
USB / RS485 interface
If the PC is not equipped
48990110
with a serial port, the interface will
connect via the USB port to obtain an RS485 communication port.
Recommended for local use and not for permanent installation.
USB/RS485 INTERFACE
RS422 / RS485 repeater
In some applications the
48990120
maximum distance and/or maximum number of devices can be exceeded.
Solution is to install an interface which amplifies the signal over a further
1200m (at 9600 bauds) for 31 devices.
Connecting telephone networks
RTC / RS232 - RS485 modem
The modem can be configured
48990200
as a master (RS232: connected directly to PC) or slave (RS485:
connected to slave device, via network).
ENERGY
MANAGEMENT
RS422/RS485 REPEATER
10
RS232-RS485 MODEM
Ethernet / RS232 - RS485 interface
Allows connection to an Ethernet network
48990300
ETHERNET/RS232-RS485 INTERFACE
IPD GROUP LIMITED
Phone: 1300 556 601
www.ipdgroup.com.au
Product Catalogue v-15 343
COMMUNICATION CONNECTIONS
RS485 - Ethernet Gateway
- Ethernet Link with MODBUS/TCP or JBUS/MODBUS RTU over TCP.
- Connect up to 247 RS485 JBUS/MODBUS slaves at 1400 to 38400 bauds.
Daisy Chain - RS485 shielded cable with twisted pair.
Diris A40 with Ethernet
gateway module.
RS485/RS232 Interface
- Signal conversion from RS485 to RS323.
- Up to 31 devices can be connected over a distance of 1200 meters at 9600 bauds.
Daisy Chain - RS485 shielded cable with twisted pair.
RS232/RS485
interface.
IPD GROUP LIMITED
344 Product Catalogue v-15
Phone: 1300 556 601
www.ipdgroup.com.au
DIRIS Digiware Metering
UNIQUE Energy Metering System
- 1 voltage measurement
module
- 1 current measurement
module
- 1 display
- current sensors
Components required to build a DIGIWARE SYSTEM:
1 x D-50 or C-31 interface.
1 x Diris U voltage module.
Up to 32 Diris I current modules (Monitor up to 192 circuits).
All modules are linked via RJ45 Digiware Bus cable.
All CT’s are connected via RJ12 CT connection cable.
EASY CONFIG software for device configuration.
Digiware modules (Build your own system)
OR
DIRIS D-50
- Multi-point display with
Ethernet Gateway
+
DIRIS C-31
- Without display
module
DIRIS U
- Voltage measurement
module
+
DIRIS I
DIRIS I
DIRIS I
- Current measurements modules
(3, 4 & 6 x current sensors input)
DIRIS DIGIWARE METERING SYSTEM
DIRIS DIGIWARE DISPLAY
Features:
- Global accuracy Class 0.5 (meter + ct) to IEC 61557-12.
- Meter accuracy Class 0.2.
- Plug & Play, RJ45 connection.
- Multi-circuit measurement.
- Common display.
- Single point voltage measurement.
- Auto configuration.
- Flexible, solid or split-core current sensors.
- Panel mount display 96 x 96mm, IP65 (front panel).
- DIN rail mount measurement modules.
- Modbus RTU RS485 communication.
- Ethernet gateway.
Description
Part No.
Control and Power supply Interface
D50 multi-point display.
48290201
96 x 96mm panel mount, IP65 (front panel).
RS485 JBUS/Modbus communication.
Ethernet gateway.
24V DC auxiliary supply.
DIRIS DIGIWARE NO DISPLAY MODULE
C-31 no display module.
48290101
RS485 JBUS/Modbus communication.
24V DC auxiliary supply.
Note: D50 or C-31 to be used in a Digiware system.
VOLTAGE MEASUREMENT MODULES
Metering Application
U-10 voltage module.
48290105
Monitoring Application
U-20 voltage module.
48290106
D-50 Display
Analysis Application
U-30 voltage module.
48290102
Note: 1 voltage module required per Digiware system.
VOLTAGE MEASUREMENT MODULE
SELECTION CHART
U-10 / U-20 / U-30
C-31
No display module
U-10 U-20 U-30
Multi-measurement
U12, U23, U31, V1, V2, V3, f
* **
U system, V system
*
Ph/N unbalance (Vnb, Vnba, Vdir, Vinv, Vhom)
*
Ph/Ph unbalance (Unb, Unba, Udir, Uinv)
*
Power quality
THDv1, THDv2, THDv3, THDu12, THDu23, THDu31
**
Individual harmonics U & V (up to rank 63)
*
Voltage dips, interruptions and swells (EN 50160)
*
Alarms On threshold
*
History of average values
*
DIRIS
DIGIWARE REPEATER MODULE
C-32 Repeater module.
48290103
For extending metering system beyond 100 metres
(max. 300 metres with 2 repeaters)
24V DC auxiliary supply.
Notes:
C-31, U-10, U-20, U-30 and C-32 are 1 DIN module wide.
C-32 Repeater
IPD GROUP LIMITED
346 Product Catalogue v-15
Phone: 1300 556 601
www.ipdgroup.com.au
DIRIS DIGIWARE METERING SYSTEM
CURRENT MEASUREMENT MODULES
Features:
- Global accuracy Class 0.5 (meter + ct) to IEC 61557-12.
- Meter accuracy Class 0.2.
- Plug & Play, RJ45 connection.
- Multi-circuit measurement.
- Auto configuration.
- Flexible, solid or split-core current sensors.
- DIN rail mount measurement modules.
- Modbus RTU RS485 communication.
Current
Description
Sensor Inputs
Part No.
Metering Application
I-30 current module
3
48290110
I-31 current module
3
48290111
I-60 current module
6
48290112
I-61 current module
6
48290113
Monitoring Application
I-33 current module
3
48290128
Analysis Application
I-35 current module
3
48290130
I-45 current module
4
48290131
Note: Up to 32 current modules can be used in a Digiware system.
I-35
CURRENT MEASUREMENT MODULE
SELECTION CHART
I-30I-31 I-33I-35I-45I-60I-61
Number of current inputs
3333466
Metering
+/- kWh, +/- kvarh, kVAh
*
*
*
*
*
*
*
Load curves****
Multi-measurement
I1, I2, I3, In, ∑P, ∑Q, ∑S, ∑PF *******
P, Q, S, PF per phase
*
*
*
Predictive power**
Current unbalance
(Inba, Idir, Iinv, Ihom, Inb)
*
*
Phi, cos Phi, tan Phi
*
*
Quality
THDi1, THDi2, THDi3, THDin *
*
*
Individual harmonics I
(up to level 63)
*
*
Overcurrents**
Alarms
On threshold *
*
Inputs/Outputs2/2
History of average values
*
*
ENERGY
MANAGEMENT
I-45
I-33
I-30 / I-31
10
Notes:
I-30, I-31, I-33 and I-35 are 1 DIN module wide.
I-45 is 1.5 DIN modules wide.
I-60 and I61 are 2 DIN modules wide.
I-60 / I-61
IPD GROUP LIMITED
Phone: 1300 556 601
www.ipdgroup.com.au
Product Catalogue v-15 347
DIRIS DIGIWARE CURRENT SENSORS (CT’s)
TE - SOLID CORE CURRENT SENSORS
Features:
- CT accuracy Class 0.2.
- Plug & Play, RJ12 connection.
- Compact miniature CT’s.
- Safe disconnection of CT secondary under load.
- DIN rail, staggered, cable, panel, bus bar mountings.
Model
Nominal Current
Range (Amps)
Part No. TE-185…20
48290500
TE-18
25…63
48290501
TE-25
40…160
48290502
TE-35
63…250
48290503
TE-45
160…630
48290504
TE-55
400…1000
48290505
…5A/CT adapter
TE-18
…5A/CT
Ø 8.6
48290599
TE Solid Core Current Sensors
DIMENSIONS
Model
TE-18
Nominal current
range (A) 5 … 63
Pitch (mm)
18
HxWxD
(mm)
45 x 28 x 20
Ø
(mm)
8.6
TE-18
DIMENSIONS
Model Nominal current Pitch H x W x D F
T
range (A)
(mm)
(mm)
(mm)
TE-25 40 … 160 25 65 x 25 x 32.5 13.5 x 13.5 17.5
TE-35 63 … 250 35 71 x 35 x 32.5
21 x 21
17.5
TE-45 160 … 630
45 86 x 45 x 32.5
31 x 31 19.5
TE-55 400 … 1000
55 100 x 55 x 32.5 41 x 41
21.5
TE-25, TE-35, TE-45, TE-55
IPD GROUP LIMITED
348 Product Catalogue v-15
Phone: 1300 556 601
www.ipdgroup.com.au
DIRIS DIGIWARE CURRENT SENSORS (CT’s)
TR - SPLIT-CORE CURRENT SENSORS
Features:
- CT accuracy Class 0.2.
- Plug & Play, RJ12 connection.
- Compact miniature CT’s.
- Safe disconnection of CT secondary under load.
Model
TR-10
TR-16
TR-24
TR-36
Range (Amps)
25…75
32…100
63…200
200…600
Part No. 48290551
48290552
48290553
48290554
DIMENSIONS
TR Split-Core Current Sensors
Nominal
Model
Current
range (A) TR-10 25 … 75
TR-16 32 … 100 TR-24 63 … 200 TR-36 200 … 600
HxWxD
Ø
A
W
C (mm)
(mm)
71 x 25 x 39
10
58
14.5
26
74 x 30 x 42
16
61
19
31
95 x 45 x 44
24
72
22
34
111 x 57 x 42
36
82
34
40.5
REGOWSKI COIL
TF - FLEXIBLE SPLIT-CORE CURRENT SENSORS
Model
TF-55
TF-120
TF-300
Nominal Current
Range (Amps)
Part No.
150…600
48290570
500…2000
48290571
1600…6000
48290572
ENERGY
MANAGEMENT
TR-10, TR-16, TR-24, TR-36
10
DIMENSIONS
TF Flexible Current Sensors
Model
TF-55 TF-120 TF-300
TF-55
IPD GROUP LIMITED
Nominal
Current
range (A)
150 … 600 500 … 2000 1600 … 6000 Ø
loop 55
120
300
L = loop
length
172
376
942
TF-120, TF-300
Phone: 1300 556 601
www.ipdgroup.com.au
Product Catalogue v-15 349
DIRIS DIGIWARE CABLES
DIRIS DIGIWARE
RJ12 CT CONNECTION CABLES
Features:
One cable per current sensor is required.
Cable length, number of cables and part numbers below.
RJ12 Cable
- Twisted pair, unshielded cable cat. III, -40°C to +85°C
(IEC61010-1).
RJ45 Cable
- Twisted pair, unshielded cable AWG24, cat. III, -40°C to
+85°C (IEC61010-1).
RJ12 CT Cable Connection
No. of cables per Part No.
Cable
length 1346
0.1m-
48290580 4829058548290590
0.2m-
48290581 4829058648290591
0.3m-
48290582 4829058748290592
0.5m-
48290595 4829059648290597
1m-
48290583 4829058848290593
2m-
48290584 4829058948290594
5m48290602 - --
10m48290603 - --
*50m 48290601
- --
* D.I.Y. cable - comes with 50 connectors. Maximum recommended length
for CT cable is 10 meters.
RJ45 DIGIWARE BUS CONNECTION CABLES
Cable
length Part No.
0.1m 48290181
0.5m 48290182
1m 48290183
2m 48290184
5m 48290186
10m 48290187
*50m 48290185
* D.I.Y. cable - comes with 50 connectors.
RJ45 Digiware Bus Cable Connection
DIRIS DIGIWARE P-15 POWER SUPPLY
Description
Part No.
P-15 Power Supply
Input: 230VAC
48290120
Output: 24VDC, 15W
Power consumption of the Digiware system is dependent
on the number and type of components used.
A higher rated power supply may be required with larger systems - consult IPD.
P-15 Power Supply
IPD GROUP LIMITED
350 Product Catalogue v-15
Phone: 1300 556 601
www.ipdgroup.com.au
DIRIS B-30 MULTI-FUNCTION METER
MULTI-FUNCTION MONITORING DEVICE
DIRIS B-30
Diris B-30
Description
Part No.
Diris B-30 multi-function meter with RS485 JBUS/Modbus 48290000
110-230V AC auxiliary supply. DIRIS B-30 FUNCTIONS
B-30
Multi-measurement
currents, voltages (ph / ph and ph / n),
*
active / reactive / apparent powers, power factor, frequency
*
Voltage/current unbalance
*
Power factor, cos Phi, tan Phi
*
Metering
kWh (+ /-), kvarh (+ /-), kVAh
*
Load curves
*
Quality analysis
THdV, THdU, THdI
*
Individual harmonics V, U & I (up to rank 63)
*
Voltage dips, cut-offs and surges (EN50160)
*
overcurrents
*
Alarms
*
Communication
RS485 Modbus
*
2 inputs (status/ pulse)
*
DIRIS B-30 ACCESSORIES
Description
Part No.
Optional Add-on Modules
2 digital inputs / 2 digital outputs.
48290030
2 analogue inputs / 2 analogue outputs, 4-20mA.
48290031
3 temperature inputs PT100 / PT1000.
48290032
RS485 Modbus communication.
48290033
Profibus communication.
48290034
BACnet IP communication.
4
8290035
BACnet MSTP communication.
48290036
Optional Module Connection
ENERGY
MANAGEMENT
Features:
- Global accuracy Class 0.5 (meter + ct) to
IEC 61557-12.
- Meter accuracy Class 0.2.
- Plug & Play, RJ12 CT connection.
- Multi-circuit measurement - 4 CT inputs (used in
1 phase or 3 phase monitoring).
- Auto configuration.
- DIN rail mount : 3 modules wide.
- Optional Bacnet module.
10
Optional Display
Single-point display (for 1 meter only).
Part No.
48290200
D-30 RJ9 cable for D30 display - 1.5m. 48290280
RJ9 cable for D30 display - 3m 48290281
96 x 96mm panel mount, IP65 (front panel).
Optional Display
Multi-point display (1 display for up to 32x B30)
Part No.
D-50
Meters using RS485 Modbus communications.
48290201
96 x 96mm panel mount, IP65 (front panel).
RS485 JBUS/Modbus communication.
Ethernet gateway.
24V DC auxiliary supply.
D-30/D-50 Display
Note:
For current sensor and RJ12 CT cable selection refer pages 348 & 350.
D-50 multi point display interfaces with B-30 meter via RS485 Modbus
connection.
IPD GROUP LIMITED
Phone: 1300 556 601
www.ipdgroup.com.au
Product Catalogue v-15 351
DIRIS G MODBUS/ETHERNET GATEWAY
DIRIS G COMMUNICATION GATEWAY
WITH EMBEDDED WEBVIEW SOFTWARE
Features:
- Automatic detection of connected devices.
- 4 Gb memory.
- Real time monitoring.
- 1 year historical consumption data (1 hour period).
- DIN rail mount : 3.5 modules wide.
- Modbus RTU/TCP RS485 communication.
Webview Software
- Display of average/instantaneous values with min/
max limits depending on the devices.
- Display of alarm history.
WEBVIEW Software for measuring and monitoring Diris G, Diris Digiware,
Diris B, Diris A & Countis metering.
DIRIS G-30 GATEWAY (NO TRENDING)
Description
Part No.
Embedded Webview software for Power monitoring and Alarm.
Diris G30 Gateway.
48290300
RS485 JBUS/Modbus and Ethernet communication,
1 digital input.
110-230V AC auxiliary supply.
DIRIS G-50 GATEWAY (WITH TRENDING)
Description
Part No.
Embedded Webview software for Power monitoring,
Alarm and Power & Energy monitoring.
Diris G50 Gateway.
48290302
RS485 JBUS/Modbus and Ethernet communication,
1 digital input.
110-230V AC auxiliary supply.
G-30 / G-50 Gateway
DIRIS B-30 ACCESSORIES
Description
Part No.
Optional Add-on Modules
2 digital inputs / 2 digital outputs 48290030
2 analogue inputs / 2 analogue outputs, 4-20mA
48290031
3 temperature inputs PT100 / PT1000
48290032
WEBVIEW Software
Optional Module Connection
IPD GROUP LIMITED
352 Product Catalogue v-15
Phone: 1300 556 601
www.ipdgroup.com.au
SPLIT CORE CURRENT TRANSFORMERS
SPLIT CORE CURRENT TRANSFORMERS
Features:
-Accuracy class: 0.5
-Wide range of openings: 20 x 30 to 160 x 80mm
-Sealable terminal cover
-Tested insulation: 3kV/1min 50Hz
TO23
Ratio CLASS CLASS Part No.
Amps 0.5
1
TO23
TO58 TO812TO816
VA
VA
100/5 1.25
192T4601
150/5 1.5
192T4602
200/5 1.5
192T4603
250/51 2
192T4625
300/51.5 3
192T4630
400/51.5 3
192T4640
500/52.5 5
192T4650
600/52.5 5
192T4660
750/52.5 5
192T4675
800/52.5 5
192T4680
800/52.5 5192T4780
1000/55 10192T4710
1250/57.5 15192T4712
1500/57.5 15192T4715
2000/510 15 192T4820
2500/5 10
15 192T4825
3000/5 15
25 192T4830
4000/515 25 192T4840
5000/515 25 192T4850
ENERGY
MANAGEMENT
TO58
10
TO812
Dimensions (mm)
Type
A
B
H
W
D
TO23
20
30
106
93
58
TO58
50
80
152
125
58
TO812
80
120
198
155
58
TO816
80
160
246
195
79
Note:
For CT shorting link terminals refer to page 442.
TO816
IPD GROUP LIMITED
Phone: 1300 556 601
www.ipdgroup.com.au
Product Catalogue v-15 353
TCB - 3 IN 1 CURRENT TRANSFORMERS
TCB 18 - 20 SERIES
Features:
-Space-saving 3 in 1 CT’s
-Two frame sizes
-Class 1 Accuracy
-Case material: Polycabonate
-Fixed screw mounting, Bus-Bar mounting or
Din-Rail mounting (mounting clips included)
-Insulation class E (120°C)
Ratio Amps
3 x 100/5
3 x 150/5
3 x 200/5
3 x 250/5
Class 1
VA
1
1.25
1.5
2.5
Part No.
192T3310
192T3315
192T3320
192T3325
Ratio Class 1
Amps
VA
3 x 250/5
2.5
3 x 300/5
3.75
3 x 400/5
5
3 x 500/5
5
3 x 600/5
5
Part No.
192T3425
192T3430
192T3440
192T3450
192T3460
TCB 22 - 30 SERIES
DIMENSIONS
TCB3 18-20
Bar or cable-through
three-phase CT
Ø cable (mm)
H x W x D (mm)
TCB3 22-30
TCB3 18-20
18
115 x 65 x 37
TCB3 22-30
22
150 x 75 x 37
Note:
For CT shorting link terminals refer to page 442.
IPD GROUP LIMITED
354 Product Catalogue v-15
Phone: 1300 556 601
www.ipdgroup.com.au
TCA and TCB CURRENT TRANSFORMERS
TECHNICAL DATA
Features:
-Compact design CT’s.
- Three Frame Sizes.
- Class 1 and Class 0.5 Accuracy.
- Insulation class E (120°C).
- Max case temerature 70°C.
- Test Voltage 3KV 50 Hz 1min.
- Case material: Polycabonate.
- Fixed screw mounting or Din-Rail mounting
(TCA21 and TCB26 only).
- Approved to IEC60044.1.
Class Class
Ratio
1
0.5
Part No.
Amps
VA
VA
TCA21
TCA21/TCA14 SERIES
50/5
1
TCA14-50/5
60/5
1.25
TCA21-60/5
75/5
1.5
TCA21-75/5
80/5
1.5
TCA21-80/5
100/5
1.5
TCA21-100/5
125/5
1.5
TCA21-125/5
150/5
1.5
TCA21-150/5
200/5
2.5
TCA21-200/5
250/5
2.5
TCA21-250/5
300/5
5
TCA21-300/5
TCB26-30....
Class Class
Ratio
1
0.5
Part No.
Amps
VA
VA
TCB44-50
TCB44-50 SERIES
150/5
1.5 TCB44-50-150/5
200/5
2.5 TCB44-50-200/5
250/5
5
TCB44-50-250/5
300/5
5
TCB44-50-300/5
400/5
10 TCB44-50-400/5
500//5
10
TCB44-50-500/5
600/5
10 TCB44-50-600/5
750/5
10 TCB44-50-750/5
800/5
15 TCB44-50-800/5
1000/5
15 TCB44-50-1000/5
TBA44-50....
DIMENSIONS (mm)
k
I
K – P1
TCA14...
ENERGY
MANAGEMENT
TCA21/TCA14....
Class Class
Ratio
1
0.5
Part No.
Amps
VA
VA
TCB26-30
TCB26-30 SERIES
50/5
1
TCB26-30-50/5
60/5
1
TCB26-30-60/5
75/5
1.5
TCB26-30-75/5
80/5
2.5
TCB26-30-80/5
100/5
1.5 TCB26-30-100/5
125/5
1.5 TCB26-30-125/5
150/5
1.5 TCB26-30-150/5
200/5
2.5 TCB26-30-200/5
250/5
5
TCB26-30-250/5
300/5
5
TCB26-30-300/5
400/5
5
TCB26-30-400/5
500/5
5
TCB26-30-500/5
600/5
5
TCB26-30-600/5
10
TCA21...
Note:
For CT shorting link terminals refer to page 442.
TCB26-30
TCB44-50
IPD GROUP LIMITED
Phone: 1300 556 601
www.ipdgroup.com.au
Product Catalogue v-15 355
CTME SERIES CURRENT TRANSFORMERS
Features:
-Single turn primary
-Sealable terminal cover as standard
-Includes mounting brackets + busbar fixing
device
-Generous primary aperture
-Fixed screw mounting or DIN rail mounting
Accuracy Class (%)
Ratio 5.03.0 2.01.00.5
AmpsVAVA VAVAVA
Part No.
CTME-1 Series for Single Turn Primary
50/5
3
CTME150
60/53
CTME160
75/53
CTME175
100/55
CTME1100
CTME-2 Series for Single Turn Primary
75/5
2.5
CTME275
100/52
CTME2100
150/53
CTME2150
200/55
CTME2200
250/55
CTME2250
300/57.5
CTME2300
400/510
CTME2400
CTME1100
CTME3500
CTME41600
CTME51200
CTME-3 Series for Single Turn Primary
150/55
CTME3150
200/55
CTME3200
300/57.5
CTME3300
400/510
CTME3400
500/515
CTME3500
600/5
10
CTME3600
800/5
15
CTME3800
1000/5
15
CTME31000
1200/5
15
CTME31200
CTME-4 Series for Single Turn Primary
400/57.5
CTME4400
600/510
CTME4600
630/510
CTME4630
800/5
7.5
CTME4800
1000/5
15
CTME41000
1200/5
15
CTME41200
1250/5
15
CTME41250
1500/5
15
CTME41500
1600/5
15
CTME41600
2000/5
15
CTME42000
CTME-5 Series for Single Turn Primary
1200/5
15
CTME51200
1500/5
15
CTME51500
1600/5
15
CTME51600
2000/5
15
CTME52000
2500/5
15
CTME52500
CTME-6 Series for Single Turn Primary
1500/5
15
CTME61500
1600/5
15
CTME61600
2000/5
15
CTME62000
2500/5
15
CTME62500
3000/5
15
CTME63000
4000/5
15
CTME64000
Note:
For CT shorting link terminals refer to page 442.
IPD GROUP LIMITED
356 Product Catalogue v-15
Phone: 1300 556 601
www.ipdgroup.com.au
CTME SERIES CURRENT TRANSFORMERS
ENERGY
MANAGEMENT
All dimensions in mm
10
IPD GROUP LIMITED
Phone: 1300 556 601
www.ipdgroup.com.au
Product Catalogue v-15 357
METERING TEST BLOCK
Features:
-Multi-point sealing.
-Captive sealing screws.
-Terminals align with standard cable holes.
-IP20 enclosure with cover fitted.
-Dimensions 148mm x 207mm x 58mm
(H x W x D) screw projection 13mm.
Description
Metering Test Block
(supplied with loose Link)
Metering Test Block
(Victoria specification)
Part No.
KWHTB01
KWHTB02
KWHTB01
A Phase
1 Phase
Meter
Three Single Phase Meter Installation with
A Phase Meter only shown for clarity
3 Phase
Meter
Metering Test Block
Secondary Conductors
Current Circuit Wiring- 4mm2
Voltage Circuit Wiring
2.5mm2
Voltage Circuit Fuses - 10A HRC
Voltage Circuit
Wiring - 4mm2
NL if required
Polarity Marks on
Supply
IPD GROUP LIMITED
358 Product Catalogue v-15
Supply Side of CTs
Phone: 1300 556 601
Load
Primary
Conductors
www.ipdgroup.com.au