Sun Bandit® Monitor

Solar Hybrid Energy Systems • Patent(s) Pending
Sun Bandit® Monitor
Sun Bandit® Monitor Installation,
Operation and Maintenance Manual.
Installation, Operation and
Solar Hybrid Energy SystemsManual
• Patent(s) Pending
Maintenance
Solar Hybrid Energy Systems • Patent(s) Pending
IMPORTANT!
Record all product serial numbers BEFORE installing
your Sun Bandit® Solar Hybrid Energy System
v1015
Sun Bandit® Solar Hybrid Energy System - Monitor Installation, Operation & Maintenance Manual v1015
1
TABLE OF CONTENTS
Introduction . . . . . . . . . . . . . . . . . . . . 3
Sun Bandit® Monitor . . . . . . . . . . . . . . . 3
Monitor Operation . . . . . . . . . . . . . . . . 4
Monitor Buttons . . . . . . . . . . . . . .
Power Generation Parameter .
Time Parameter . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
4
. 4
. 4
Sun Bandit® Monitor Installation Procedure . . 5
Monitor Installation . . . . . . . . . . . . . 5
Wiring Connections . . . . . . . . . . . . . 6
Monitor Technical Data . . . . . . . . . . . . . 8
2
www.sunbandit.us
INTRODUCTION
Congratulations on your decision to purchase Sun Bandit® products! Used with other Sun Bandit® products,
the Monitor will improve safety, maximize solar energy harvest, increase system reliability and simplify your
Sun Bandit® system maintenance and management.
The Monitor is a smart ammeter equipped with an advanced Micro Control Unit and a high-precision
electrical energy measurement chip. An LCD screen displays comprehensive performance monitoring
of your Sun Bandit® Microinverter installation.
The Sun Bandit® Monitor is comprised of five key elements:
• Instantaneous Voltage, Current, and Power output
• Peak Voltage/Current history
• Volatile-store reading for a single period and/or
accumulated total power generation
• Time period being measured
• Summary of peak measurements and
accumulated totals
SUN BANDIT® MONITOR
The Monitor is composed of three parts:
• the LCD screen
• the Control Buttons
• the LED Indicator Light
Note: The Monitor screen may flash when the circuit
is open, this does not indicate a fault condition.
LCD Screen
Control Buttons
LED Indicator Light
Figure 1: Monitor
Sun Bandit® Solar Hybrid Energy System - Monitor Installation, Operation & Maintenance Manual v1015
3
MONITOR OPERATION
The Monitor works when connected with a power source. The indicator light and the background light will
be on and the LCD will automatically update the readings every two seconds. The default values are the
instantaneous power and the current time. You can check all the readings or clear the records as you
need using the four buttons:
Monitor Buttons
Button
Method
Parameter
Time Period
Menu
Press quickly
Live Voltage/Current/Power
Current Cumulative Power
Current
Energy
Press quickly
Cumulative Energy
All operation hours
Max
Press quickly
Maximum Voltage/Current
All operation hours
Clear
Hold 3 sec.
Clear all values – peak and cumulative
Power Generation Parameter
The related power generation parameters are shown at the bottom of the LCD SCREEN. Using the three
buttons: MENU, ENERGY and MAX, the Monitor provides access to server parameters. The relevant
information and the unit of measure at the right bottom corner will display clearly on the screen. The voltage and
power will be calculated in 0.1, and the current and generated power will be calculated in 0.001.
Time Parameter
Time records show in the middle of the screen. The Monitor provides two kinds of time period records:
1. the current time (T)
2. the cumulative time (CT)
You can use the MENU, ENERGY and MAX buttons to change the two periods as needed. The smallest time
measurement unit is one minute and the longest cumulative number of hours is 99999.
4
www.sunbandit.us
SUN BANDIT® MONITOR INSTALLATION PROCEDURE
Monitor Installation
A.Choose appropriate location to mount the Sun Bandit® Monitor.
B.Using appropriate fasters for Ø0.190” (4.83mm) holes, attach the Sun Bandit®
Monitor in the desired location using the four (4) pre-drilled holes.
Ø0.190” (4.83mm)
4 holes
Figure 2
Ø1-1/8” (28.58mm)
2 holes for
3/4” NPT fittings
Figure 3
Sun Bandit® Solar Hybrid Energy System - Monitor Installation, Operation & Maintenance Manual v1015
5
Wiring Connections
A.Loosen the bolts in the middle of the cover board, remove the board
and you will see four binding posts.
Figure 4
B.Loosen the bolt and pull up the flexible slider.
C.Insert wire into the area specified below and tighten the bolt.
D.Re-attach the cover board and tighten the bolts.
Bolt
Binding Post
Figure 5
Flexible Slider
Insert Wire
continued on next page
6
www.sunbandit.us
Wiring Connections continued
The two binding posts on the left corner are used to connect with the LINE (L) and NEUTRAL
(N). The two righthand binding posts are used to connect with the Sun Bandit® Water Heater.
White
Black
Black
Appliance
White
Microinverter
Figure 6
Sun Bandit® Solar Hybrid Energy System - Monitor Installation, Operation & Maintenance Manual v1015
7
MONITOR TECHNICAL DATA
Measuring Data
Input Voltage Range
20~280 VAC, 50/60 Hz
Input Current Range
0~15A
Power Range
0~4200W
Cumulative Energy Range
0~99999KWH
Cumulative Run Time Range
0~99999H
Accuracy Tolerance
1%
Mechanical Data
8
Ambient Temperature Range
-20°C to 70°C (-4°F to 158°F)
Cooling
Natural Convection; No Fans
Enclosure Environmental Rating
Indoor - NEMA 1 (IP30)
Enclosure Openings
Two Ø1-1/8” for 3/4” NPT fittings