AlphaVision PC Series III 192x48 and 192xx64 Sign Electrical

Electrical Installation
AlphaVision™ PC Series III
192x48 and 192x64 Signs
1
Open the side of the sign labeled “CONTROLLER SIDE”.
WARNING! Hazardous voltage. Contact with high voltage may cause death or serious injury. Always disconnect
power to unit prior to servicing. Possible fall or crush hazard. Remain clear of door when opening.
A. Disconnect all power from the sign at the power source.
B. Turn the controller-side panel latches counter-clockwise and carefully raise the panel of the sign.
Support the weight
of the panel.
Open the panel identified as
CONTROLLER SIDE on this label,
attached to the bottom of the sign.
2
Do not allow panel to
swing open freely.
Open both panels.
Connect the sign and messaging computer to an Ethernet network.
A. Run Category 5 T568A or T568B wire from the network into the sign communications conduit.
(Communications conduit is labeled Ethernet and is located on the side of the sign).
B. Position the wires into the channels on the modular network adapter (see diagram) and use a
110 punch-down tool to push the wires into the channels.
NOTE:
Do not separate the twisted pairs more then 0.5 inches from the termination point.
Inside view (shown with optional service
outlet, light, sound cards, and speaker)
Modular network adapter
110 punch-down tool
Category 5 T568A (8 wire)
110 type connector
RJ45 jack
Category 5 T568B (8 wire)
110 type connector
RJ45 jack
Wht/Blu
5
Wht/Blu
5
Blu/Wht
4
Blu/Wht
4
Wht/Org
3
Wht/Org
1
Org/Wht
6
Org/Wht
2
Wht/Grn
1
Wht/Grn
3
Grn/Wht
2
Grn/Wht
6
Wht/Brn
7
Wht/Brn
7
Brn/Wht
8
Brn/Wht
8
Position wires into channels on the modular network
adapter as shown below.
5
1
43
27
6
8
© Copyright 2008 Adaptive Micro Systems LLC. All rights reserved.
Adaptive Micro Systems • 7840 North 86th Street • Milwaukee, WI 53224 USA • 414-357-2020 • 414-357-2029 (fax) • http://www.adaptivedisplays.com
Adaptive is a registered trademark of Adaptive Micro Systems. AlphaVision is a trademark of Adaptive Micro Systems.
All other brand and product names are trademarks or registered trademarks of their respective companies.
April 8, 2008
1234610508 rev. B
3
If applicable, connect the speakers to the Tune Blaster sound cards.
Each sign can support up to 2 speakers. Each speaker should be 8 ohms and at least 10 watts.
A. For each speaker, insert one non-metallic, compression type connector into a speaker conduit.
B. Run speaker wire (Belden 8471 or equivalent) from each speaker through the connector to the sound
card inside the sign.
C. Connect the wires to the sound card using a #1 screwdriver (1/16” wide tip) to depress the spring clip
and insert the speaker wire.
D. Repeat steps A, B, and C for an additional Tune Blaster sound card, if applicable.
Inside view (shown with optional service
outlet, light, sound cards, and speaker)
CH4B –
CH4B +
CH4A –
CH4A + SPEAKERS
CH3B –
(CH3-4)
CH3B +
CH3A –
CH3A +
Sign side view
TUNE
BLASTER 1
CH2B –
CH2B +
CH2A –
CH2A + SPEAKERS
CH1B –
(CH1-2)
CH1B +
CH1A –
CH1A +
Speaker conduit openings are
located on the side of the
sign. Each opening has a
diameter of 5/8in.
4
Close the sign.
WARNING! Possible crush hazard. Remain clear of door when closing.
Carefully lower the panel and turn the latches on the panel clockwise to close panel.
5
Connect power to the sign.
WARNING! Hazardous voltage. Contact with high voltage may cause death or serious injury. Always disconnect
power to unit prior to servicing.
Make sure power is not applied at the power source and the sign is not connected to a ground fault interrupt
(GFI) circuit. The sign must be properly earth-grounded according to local and national electrical codes.
A. Run one single phase 120VAC/60Hz line into the power conduit on the side of the sign with the
disconnect box.
B. Open the disconnect box and connect the wires to the fuse terminals. (See diagram).
C. Close the disconnect box. Apply 120VAC/60Hz power at the power source and move the disconnect
switch to the ON position.
D. Confirm that the neon green indicator light is lit, indicating that power is supplied to the sign.
Disconnect box - inside view
Disconnect box
Hot
(Line)
Voltage
Full Load
Amps
Single-Sided
115V
5.5 amps*
Double-Sided
115V
8.0 amps*
Single-Sided
115V
6.0 amps*
Double-Sided
115V
9.5 amps*
MODELS
Disconnect
Switch
192x48
Ground
192x64
Indicator light
* Add 10 amps for units containing optional AC outlet.
Neutral