Access Control Products
Model CPA-ST-ALN
Mounting Instructions
1. Drill mounting holes using template provided
2. Connect keypad using WIRING DESCRIPTION
•
For 12VDC inductive loads such as electric strikes and electromagnetic locks, the enclosed varistor
must be connected in parallel with the load, at the load terminals and not in the keypad.
•
Ensure power supply is of correct rating, taking into account the current requirements of the locking
items and accessories.
•
Do not insert security plugs into fixing holes until all installation and testing has been completed.
Wiring Description
Brown
Blue
Grey
Red
Yellow
White & Pink
Green
LED signaling explanation
GREEN LED: Door Strike activated
RED LED : Normal Operation : 3 sec. ON = Wrong Code Entry
Slow flashing = Wrong code entry 3 times
Power supply 8 to 24 V DC or AC
Relay Common
Relay N.O
C.O. Form C ; Contact A Amp.
Dry contact for door strike
Relay N.C.
Remote opening door (Dry contact only!)
Housing Ground
RED LED in Programming Mode:
Fast flashing = Programming different functions
Slow flashing = programming stand-by
Very Fast flashing = Erasing All user codes
Testing the unit
Enter the master code [1 2 3 4 #]
The Door Relay changes its contacts for 5 sec.
The Green LED will light up for 5 sec. Repeat this step 2,3 times.
If the master code is wrongly typed in, the Red LED lights up for 3 sec. re-enter the Code as soon as the
LED goes OFF.
IMPORTANT: CHANGE THE FACTORY SET MASTER CODE WHEN YOU PROGRAM YOUR UNIT FOR
USE. THERE IS NO WAY TO RECOVER THE NEW MASTER CODE IF IT IS LOST OR FORGOTTEN.
THE UNIT CAN BE RESET TO FACTORY PRESETS AND CUSTOMISED AGAIN.
Apply power to the keypad
Initialization
The keypad’s buzzer will sound briefly, the red LED will illuminate briefly
Initialisation is now complete, with a default master code of 1-2-3-4 and a 5-second open
door.
Programming the keypad
•
Enter **1-2-3-4 ** The keypad enters programming mode, the red LED flashes
•
If no further information is added, the unit will revert to normal operation after a 12 second delay.
To exit programming press #.
There are eight programming options:
1.
2.
3.
4.
Set new master code
Set new user code
Erase a user code
Erase all user codes 5.
6.
7.
8.
Set door opening time (1-99s)
Set door output to latch mode
Set “remote opening” time (1-99s)
Set “remote opening” to latch mode
1. To set a new master code
•
•
•
•
•
•
•
•
Enter ** 1-2-3-4 ** Enter 2
Enter 0-0-0 #
Enter new 4-8 digit code
Enter # Re-enter the new master code
Enter #
Enter #
The keypad enters programming mode, the red LED flashes
The red LED illuminates for 2 seconds and then flashes
The red LED illuminates for 2 seconds and then flashes
This is the new master code, record the number & keep it safe
The red LED illuminates for 2 seconds and then flashes
The red LED illuminates for 2 seconds and then flashes
To exit the programming mode
To set a new master code of 112233
• Enter **1-2-3-4** 2 000# 112233# 112233# #
2. To set a new user code
• Enter **mastercode** • Enter 2
• Enter address of new user code
• Enter # • Enter new 4-8 digit user code
• Enter #
• Re-enter the new 4-8 digit user code
• Enter #
The keypad enters programming mode, the red LED flashes
The red LED illuminates for 2 seconds and then flashes
i.e 001 (001-200 accepted)
The red LED illuminates for 2 seconds and then flashes
This is the new master code, record the number & keep it safe
The red LED illuminates for 2 seconds and then flashes
The red LED illuminates for 2 seconds and then flashes
The new code is added, to add new codes continue from the second step, changing the address each time.
When finshed enter an additional # to exit programming mode.
To set a new user code of 6626 in address 1
• Enter ** master code ** 2 001# 6626# #
To set a new user code of 6626 in address 1 & 7788 in address 2
• Enter ** master code ** 2 001# 6626# 2 002# 7788# 7788# #
3. To remove an individual user code
(Only the uder codes address are removable, the master code may be changed but not removed)
• Enter ** master code ** • Enter 3
• Enter address of user code to be removed
• Enter # • Re-enter address of user code to be removed
• Enter #
• Enter #
• Enter #
4. To remove all user codes
The keypad enters programming mode, the red LED flashes
The red LED illuminates for 2 seconds and then flashes
i.e 001 (001-200 accepted)
The red LED illuminates for 2 seconds and then flashes
i.e 01 (001-200 accepted)
The red LED illuminates for 2 seconds and then flashesthe code is removed
The red LED illuminates for 2 seconds and then flashes,
the code is removed
Exit the programming mode
• Enter **master code** The keypad enters programming mode, the red LED flashes
• Enter 4
The red LED illuminates for 2 seconds and then flashes
• Enter master code
• Enter #
• Enter #
The red LED illuminates for 2 seconds and then flashes,
All code addresses are removed
• Enter #
Exit the programming mode
5. To set door opening time
• Enter **master code** • Enter 1
• Enter door open time
• Enter #
• Enter #
The keypad enters programming mode, the red LED flashes
The red LED illuminates for 2 seconds and then flashes
(01-99) 05 = 5 seconds
The red LED illuminates for 2 seconds and then flashes
Exit the programming mode
To set the door open time to 10 seconds Enter ** master code ** 1 10 # # 6. To set door output to latch mode (On-Off)
•
•
•
•
•
Enter **master code** Enter 1
Enter 0 0
Enter #
Enter #
The keypad enters programming mode, the red LED flashes
The red LED illuminates for 2 seconds and then flashes
The red LED illuminates for 2 seconds and then flashes
The relay is set to latching mode
7. To set remote door opening time
•
•
•
•
•
Enter **master code** Enter 5
Enter door open time
Enter #
Enter #
The keypad enters programming mode, the red LED flashes
The red LED illuminates for 2 seconds and then flashes
(01-99) 05 = 5 seconds
The red LED illuminates for 2 seconds and then flashes
Exit the programming mode
To set the remote door opening time to 10 seconds Enter ** master code ** 5 10 # # 8. To set remote door opening time
•
•
•
•
•
Enter **master code** Enter 5
Enter 0 0
Enter #
Enter #
The keypad enters programming mode, the red LED flashes
The red LED illuminates for 2 seconds and then flashes
The red LED illuminates for 2 seconds and then flashes
The relay is set to latching mode Operating the Keypad
• Enter user code #
The relay operates and green LED illuminates
In three incorrect attempts are made to enter a user code, the keypad will lock out for 30 seconds
Data reset
In the event that programming administration is lost, or errors have been made in programming,
it is possible to set the keypad master code back in the factory default.
•
•
Power up the unit
Enter **1234# during the 3 seconds
During the first 3 seconds. The red LED is ON
The unit will sound 3 times and the Data will be
restored as follows
Factory default settings:
Master Code: 1234
User Code: 567890 (please erase this code at addess 200)
Door opening times: 5 seconds
Trouble Shooting
The keypad does not ‘respond’ when activating the keys.
1. Make sure the electronic unit has been properly wired to the mains and the power has not been cut-off.
The Keypad ‘responds’ but the door does not open
1. Make sure the green LED lights uo.
2. If not the entered code has not been programmed yet. Please refer to ‘Programming’
3. Enter the master Code and make sure the door opens correctly. If not check the wiring and the strikes integrity.