CMC-001

CMC-001
Instruction Manual USB COMMUNICATION CABLE
No. CMCJE2 2012.03
This manual contains instructions for functions and usage of the USB communication
cable (CMC-001). To ensure safe and correct use, thoroughly read and understand
this manual before using this cable. To prevent accidents arising from the misuse of
this cable, please ensure the operator receives this manual.
(Be sure to read these precautions before
using this cable.)
Indicates procedures which may lead to
dangerous conditions and cause superficial to
medium injury or physical damage or may degrade
or damage the product, if not carried out properly.
Safety precautions
Caution
Safety precautions
(1) Do not confuse the direction of the USB plug when connecting this
cable to the USB port. If the plug cannot be inserted smoothly, do not force
it to enter. This may damage the plug or port.
(2) Do not bend or pull forcibly or put any heavy object on the cable.
(3) Do not connect or remove this cable during communication.
This may cause damage or malfunction.
(4) Do not allow the metallic section of this cable to come into contact with
external power terminals.
(5) Do not handle the cable plug with wet hands. This may result in electric shock.
Precautions
Caution
Select [Include this location in the search], and click the [Browse].
Select the USB driver folder of the CD-ROM, and click [OK].
7 Click the [Next>].
8 [Completing the Found New Hardware Wizard] display appears.
Click the [Finish] button.
9 Step 2 display appears again. Repeat steps 3 to 8 .
Driver installation is completed.
(3) Confirm the COM port number.
1 Select [Start] – [Control panel], and click.
2 Click [Performance and maintenance].
3 Click [System]. [System properties] display appears.
4 Click on the [Hardware] tab, and click [Device manager] button.
5 If [USB Serial Port (COM3)] is indicated in the [Ports (COM & LPT)],
COM port has been allotted No.3. (e.g.) (Fig. 3-1)
(e.g.)
5
6
(Fig. 3-1)
Close the [Device manager], [System properties] display and [Control panel].
(4) Confirm communication between a PC and controller.
Select the COM port number confirmed at step (3), and start communication
after wiring.
Simplified communication software and various monitoring software are
provided for confirming communication. Monitoring software can be
downloaded from our website. (http://www.shinko-technos.co.jp/e/)
(Registration required.) For details, contact our agency or us.
6
(1) Ensure the cable is used under the following conditions:
• A minimum of dust, and an absence of corrosive gases
• No flammable, explosive gases
• No mechanical vibrations or shocks
• No exposure to direct sunlight, an ambient temperature of 0 to 50 (32 to
122 ) that does not change rapidly, and no icing
• An ambient non-condensing humidity of 35 to 85%RH
• No large capacity electromagnetic switches or cables through which large
current is flowing
• No water, oil, chemicals or where the vapors of these substances can
come into direct contact with the cable
• Ambient temperature of this cable must not exceed 50 (122 ) if mounted
within the control panel.
(2) It sometimes takes time for the PC to identify the cable when the USB
plug of this cable is connected to the PC. However, this is not a malfunction.
Be sure to confirm the COM port number before starting communication.
(3) Do not extend this cable using an extension cable when connecting to the
PC. A malfunction may occur.
(4) Use a soft, dry cloth when cleaning this cable.
(Alcohol based substances may deface or tarnish the cable.)
4. Wiring
CMC-001-1
JCS-33A(Max 31 units)
YA(-)
YB(+)
COM
Shielded wire
13 YA(-)
14 YB(+)
15 SG
Shielded wire
1. Model
1.1 Model
13 YA(-)
14 YB(+)
15 SG
Controller side connector
Y type terminal
Ferrules
Modular connector
CMC-001-1
CMC-001-2
CMC-001-3
1.2 How to read the model label
The model label is attached to the case.
Model
Cable length
Serial number
NCL-13A(Max 31units)
(Fig. 1.2-1)
20
CMC-001-1
USB plug
75
80
CMC-001-2
COM
YA(-)
YB(+)
+
C
A
B
Screw type plug for
lines (sold separately)
40
3-1.25-YASS3.5
500
3000
PC
PC USB port
(Fig. 2-1)
5. Uninstalling the USB driver
40
3-AI0.25-8YE
75
80
500
3000
(Fig. 2-2)
Modular connector TM20P-66P
80
3000
3. Installing USB driver
500
(Fig. 2-3)
(1) Turn the power supply to the PC ON, and start Windows.
(2) Install the driver.
Install the driver from the CD-ROM provided.
Install the USB driver and virtual COM port driver.
The same displays for installation will appear twice.
[Based on using a Windows XP system]
For installation using a Windows Vista/7 system, refer to “Setup_E.txt” in the
USB driver folder of the CD-ROM.
If driver installation has been already completed, go to step (3).
1 Connect the USB plug of this cable with the USB port of the PC.
2 After a short while, [Found New Hardware] is indicated.
Then [Found New Hardware Wizard] display appears.
3 Select the [Install from a list of specific location (Advanced)], and click
the [Next>].
4 Click [Search for the best driver in these locations].
(Fig. 4-1)
(1) Select [Start] – [Control panel], and click.
(2) Double-click the [Add or Remove Programs].
(3) Click the [FTDI USB Serial Converter Drivers], and
click the [Change/Remove] button. [FTDI Uninstaller] display appears.
(4) Click the [Continue] button.
(5) Click the [Finish] button.
Uninstalling the driver is completed.
6. Specifications
40
CMC-001-3
CMC-001-3
CDD
DCL-33A bottom view
CMC-001-3
2. Names and external dimensions(Scale: mm)
CMC-001-2
DCL-33A(Max 31units)
13 YA(-)
14 YB(+)
15 SG
USB I/F standard
Corresponds to USB Specification 2.0
DTE (PC side) speed 9600/19200/38400bps,
Connector specification PC side: USB plug (Type A plug)
Controller side: RS-485 (Y terminal, Ferrules, Modular connector)
Operating system
Windows XP/Vista/7 (Japanese/English)
Personal computer
OS certified PC with USB port and CD-ROM drive (Intel
Pentium processor or compatible microprocessor)
Case (Material, Color) ABS, Black
Cable (Length, Color) 3m (can be extended in units of 1m fixed length), Black
Power source
Bus power (Supplied from PC via USB)
Supply voltage
5V DC
Ambient temperature 0 to 50 (32 to 122 ) (No icing)
Ambient humidity
35 to 85%RH (Non-condensing)
Weight
Approx. 130g
Environment spec
Conforms to the RoHS directive.
Accessories
CD-ROM: 1, Instruction manual: 1 copy
SHINKO TECHNOS CO., LTD.
2-5-1, Senbahigashi, Minoo, Osaka, 562-0035, Japan
TEL: +81-72-727-6100 FAX: +81-72-727-7006
URL: http://www.shinko-technos.co.jp
E-mail: overseas@shinko-technso.co.jp
Download PDF
Similar pages
774KB
1,199KB
1,732KB
RD-500series
Karta katalogowa RD-502-M0, RD-515-M0, RD-515-H0 i RD-5CF-H0 (j. ang) 2012-11
Conceptronic USB to Serial Cable (9 and 25 pins)
SCCT
SCPT
IC610MDL129
2,444KB