CM9760-SAT Matrix Switcher

PRODUCT SPECIFICATION
control site
CM9760-SAT Matrix Switcher
CM9740/CM9760 SATELLITE VIDEO MATRIX SWITCHER, 16 X 4
Product Features
• 16-Input Satellite Switcher
• 4 Outputs; Programmable for Local Monitoring or Remote Tie Lines
CM9760-SAT (FRONT)
• 16 Alarm Inputs for Both Local and Remote Alarm Handling
• Economical Solution for Remote Switching
• Compatible with Both CM9740 and CM9760 Systems (Requires
Version 7.80.003 Software or Later)
• On-screen Programming via Local KBD300 Keyboard or Remote
CM9760-KBD Keyboard
CM9760-SAT (BACK)
The CM9760-SAT allows you to distribute switching capability
around a facility, reducing the number of coaxial cable runs to the
9740/9760 matrix and allowing local monitoring at the satellite
switch locations. Up to 16 cameras can be connected to one
CM9760-SAT. Four outputs are provided. At least one must be used
for video feed to a camera input on the CM9740/CM9760 matrix
bay. The others can be used for either local monitors or additional
video feeds. This allows 16 cameras to share
Cameras can be selected for viewing and controlled from either the
main keyboard at the CM9740/CM9760 matrix bay or from a local
keyboard at the satellite unit. In addition to camera selection and
control, the satellite provides 16 alarm inputs that can transport
alarms to the main control center.
The KBD200A and KBD300A keyboards can be used with the
CM9760-SAT.
• one video feed, one camera at a time, and three local monitors; or
• two video feeds, two cameras at a time, and two local monitors; or
• three video feeds, three cameras at a time, and one local monitor
(see illustration below); or
• four video feeds, four cameras at a time, and no local monitor.
REMOTE SITE
LOCAL SITE
CPU
RS-422
DATA
LINE
1-16 CAMERAS
MATRIX
BAY
CM9760SAT
VIDEO FEEDS
CM9740/CM9760
KBD300A
CM9760-KBD
LOCAL MONITOR
DataFAX
SPEC: 21510
MANUAL: Not Available through DataFAX
®
C1510 / REVISED 10-02
International Organization
for Standardization;
Registered ISO 9001
TECHNICAL SPECIFICATIONS
MODELS
SAT COM CONNECTIONS
CM9760-SAT
Satellite video matrix switcher, 16 inputs by
4 outputs, NTSC
Satellite video matrix switcher, 16 inputs by
4 outputs, PAL
CM9760-SAT-X
Connector Type
Data Ports
COM 1
(Receiver Control)
Note: Requires 9740/9760 System Software Version 7.80.003 or later
COM 2
(Comm Interface)
RELATED PRODUCTS
KBD200A
KBD300A
KBDKIT
Desktop keyboard, multi-speed PTZ.
Desktop keyboard, variable-speed PTZ.
Remote keyboard wiring kit. Required if
connecting multiple keyboards to the remote
keyboard port. Includes RJ-45 wall block and
120 VAC to 12 VAC transformer.
(One kit required for each keyboard.)
Same as KBDKIT except includes 230 VAC to
12 VAC transformer.
KBDKIT-X
SWITCHING
Switching Duration
Programmable; user defined between 1 and
99 seconds
Programmable Number
of Steps per Sequence
Maximum Number of
Sequences
Sixteen
Four
VIDEO
Number of Inputs
Number of Outputs
Level
Connector Type
Video Fail Detection
Type
Action
Connector Type
Bandwidth
Frequency Response
Gain
Differential Gain
Differential Phase
Tilt
Signal-to-Noise
DC Output
Cross Talk
Sixteen
75-ohm unbalanced terminating or looping;
jumper selectable
Four (maximum)
75-ohm unbalanced
1 Vp-p
Panel-mount BNC
Vertical sync detector
Switch to back-up sync generator
Panel-mount BNC
17 Mhz
Flat to 8 Mhz, ±1.0 dB to 15 Mhz
Unity (±1 dB)
2% typical
0.2 degree typical
0.5% typical
-55 dB (peak-to-peak vs. RMS noise)
Zero volts
-50 dB typical at 3.58 Mhz
CHARACTER GENERATOR
Display
Program Menus
White with black border
Raster background with white characters
One 12-pin connector with mating plug
(supplied)
RS-422, P protocol; program selectable baud
rate
RS-422, 9600 baud, odd parity, one stop bit
KEYBOARD INTERFACE
Protocol
Number of Ports
One Local
One Remote
Number of
Independent Keyboards
Data Rate
Keyboard
Two
RJ-45, 8-pin modular (powered)
6-pin header with mating plug
(KBDKIT required)
Four (combined total)
9600 baud
ALARM INTERFACE INPUTS
Number of Inputs
Connector Type
Sensing
Sixteen
12-pin screw terminal
Programmable, N.O./N.C.
AUXILIARY OUTPUTS
Number of Outputs
Connector Type
Contact Configuration
F1
F2 and F3
Three
12-pin screw terminal
Form C, 0.5 amp at 125 VAC maximum
Open collector, 32 VDC, 25 mA maximum
POWER SUPPLY
Input Voltage
CM9760-SAT
CM9760-SAT-X
Power Consumption
Ambient Operating
Temperature
Humidity
120 VAC, 50/60 Hz
230 VAC, 50 Hz
10 watts
20° to 120°F (-7° to 49°C)
10% to 90%, non-condensing
PHYSICAL SPECIFICATIONS
Dimensions
Mounting
Weight
CM9760-SAT
CM9760-SAT-X
Shipping Weight
3.5" H x 19.0" W x 10.5" D (2 RUs)
(8.89 x 48.26 x 26.67 cm)
Factory configured for EIA rack mount; rack
ears can be removed for wall mount or
free-standing applications.
10.15 lb (4.61 kg)
10.06 lb (4.56 kg)
11 lb (4.99 kg)
CERTIFICATIONS
•
•
•
•
®
CE, Class B (CM9760-SAT-X)
UL Listed (CM9760-SAT)
UL Listed to Canadian safety standards (CM9760-SAT)
FCC, Class A (CM9760-SAT)
Pelco Worldwide Headquarters:
3500 Pelco Way, Clovis, California 93612-5699 USA
USA & Canada Tel: (800) 289-9100 • FAX (800) 289-9150 • DataFAX (800) 289-9108
International Tel: (559) 292-1981 • FAX (559) 348-1120 • DataFAX (559) 292-0435
www.pelco.com
Specifications subject to change without notice.
©Copyright 2002, Pelco. All rights reserved.