T2
GSM Elderly Care Alarm
An Advanced
Programmable
Multifunctional
Elderly Care Alarm
In The Worldwide!
Telecare & Telehealth System
User Manual
Ver 1.0
Date Issued: 2015-05-01
All rights reserved.
King Pigeon Communcation Co.,Ltd
T2 --- GSM Elderly Care Alarm System
Table of contents
1. Product details -----------------------------------------------------------------------3
2.Safety Directions --------------------------------------------------------------------------4
3.Product Schematic ------------------------------------------------------------------------5
4.Easy setting by keypad-------------------------------------------------------------------7
5.Add wireless sensors------------------------------------------------------------------9
6.How T2 works for elderly?----------------------- ------------------------------------------10
7.Setting & Operation by SMS commands -----------------------------------------------12
8.GPRS Parameters --------------------------------------------------------------------------13
9.SMS Content List -----------------------------------------------------------------------14
10.Quick Setting Menu------------------------------------------------------------------------15
11.Warranty --------------------------------------------------------------------------------15
This handbook has been designed as a guide to the installation and operation of K3 Panel.
Statements contained in the handbook are general guidelines only and in no way are designed to supersede the instructions contained with other products.
We recommend that the advice of a registered electrician be sought before any Installation work commences.
The manufacturer, its employees and distributors, accept no liability for any loss or damage including consequential damage due to reliance on any material contained in this handbook.
The manufacturer, its employees and distributors, accept no liability for GSM Network upgrading or SIMCard upgrading due to the technology specifications contained in this handbook.
Page 2 of 15 Ver 1.0
T2 --- GSM Elderly Care Alarm System
1. Product details
The T2 GSM Elderly Care Alarm is an innovation solution of telecare field that especially for the senior, elderly, aged people who living independently.
The T2 can be used as a safety protection, temperature monitoring, daily activities monitoring, bedtime monitoring, fall alarm and emergency call system, away/stay at home monitoring,or like a normal telephone.
8 fast dial buttons which can paste photos, these buttons can be setting as Police, Relatives, Taxi, Firefighting,
Doctor, Neighbor or others for quickly dial out. So easy for Push-to-Talk ! And large keypad can dial to any other phone numbers when needed.
The T2 GSM Elderly Care Alarm also can be used as a telecare system, it can report the elderly daily actions.
Includes elderly away/back home time, remind to take medicine, go to sleep and get up time, if not get up in time then can generate alarm to receivers or central monitoring system (CMS) remotely.
Moreover, T2 can be used as a GSM Alarm system,supports wireless SOS button, wireless fall detectors, wireless carbon monoxide detector, wireless gas leakage detector, wireless water leakage detector, wireless smoke detector, wireless motion detectors and so on. Once the wireless detectors activated, it will generate alarm to receivers or central monitoring system (CMS) remotely.
All of these wireless detectors can provide the safety protections to the senior, elderly, aged people who living alone.
One sensitive thermometer inside,T2 can measure the home temperature and send alert SMS text when temperature exceed high/low threshold.
Features:
Fashion hand free design, large keyboard;
7*24 solution: take care of elderly get up,medical,SOS,fire,smoke,water,gas,sports,bedtime,etc.
Large LCD display current time, temperature, and alarm events;
GSM/GPRS wireless transmission, no distance limitation;
Bedtime/Get up not on time alarm;
Away/Back home time notice;
Supports variety wireless detectors, includes fall detector, CO detector,smoke detectors and so on;
Equips 8 quick dial numbers, and also can dial other numbers by keyboard;
Android app and iOS App can display the bedtime and away/back home trends;
3-Timer for alerting to take medicine or other activaties.
Backup rechargeable battery.
GPRS data transmiite Contact ID protocol data to CMS available.
Page 3 of 15 Ver 1.0
T2 --- GSM Elderly Care Alarm System
Specification and dimensions
GSM Frequency Quad-band 850/900/1800/1900MHz
Wireless zones
16
Wireless Frequency
433.92MHz
Wireless distance Max.100m in open air
Siren Output 12VDC/1A
DC Power supply 9~24VDC/1A
Power consumption 12V input Max. 50mA/Average 25mA
SIM Card Supporting 3V SIM Card
Antenna
50 Ω SMA Antenna interface
Temperature range -20~+60 °C
Humidity range Relative humidity 90%
Backup battery 3.7V/900mAH
Exterior dimension 24.5*16.5*6.6cm (9.6*6.5*2.6 inch)
Net Weight 550g (1.2lb)
Standard Packing List
Main unit * 1
AC/DC Power adaptor *1,
User Manual & PC Software CD x1
Applications
Residential: Home safety alarm, elderly living monitoring.
Business: Aging care, telecare, healthcare,etc.
2.Safety Directions
Optional Accessories :
PIR Motion Sensor,
Door Magnetic contact Sensor,
Smoke detector
Gas leakage detector
Water flood sensor
Safe Startup
Do not use T2 when using GSM equipment is prohibited or might bring disturbance or danger.
Interference
All wireless equipment might interfere network signals of T2 and influence its performance.
Avoid Use at Gas Station
Do not use T2 at a gas station. Power off T2 when it near fuels or chemicals.
Power it off near Blasting Places
Please follow relevant restrictive regulations. Avoid using the device in blasting places.
Reasonable Use
Please install the product at suitable places as described in the product documentation. Avoid signal shielded by covering the mainframe.
Use Qualified Maintenance Service
Maintenance can be carried out only by qualified maintainer.
Page 4 of 15 Ver 1.0
T2 --- GSM Elderly Care Alarm System
3. Products schematic
Front view
Setting Call list Alarm list
Fast dial relatives
Speaker
Keypad
Back/Delete
Medical, Police
Taxi/Cab, Neighbor
Stay at home Away
Answer End/Exit Microphone
Interface
Display
Confirm,Error,Power
Date and Week
GSM Signal
Temperature, Volume,List
Time, and number area
Smoke,Gss, CO alarm Alarm clock
Page 5 of 15 Ver 1.0
T2 --- GSM Elderly Care Alarm System
Typical Status:
Registering,No GSM signal, GSM Signal good,
AC/DC adaptor lost. Power by AC/DC adaptor
SOS alarm(3 icons flash together) Alarm Clock(flash)
On phone call (in or out) Volume adjust (range: 1~5)
List
T2 can record last of 20 alarm events and last of 20 call events(in & out).
Press to view the alarm events.
Press to view call list, and press can call back to this number.
Alarm List (On the 17 th
record, Call list, (On the 19 th
record, zone #3 alarm at 15:19,May 12.) Phone 13510150873 on May 20).
Page 6 of 15 Ver 1.0
T2 --- GSM Elderly Care Alarm System
4.Easy setting
Start:
Insert mobile SIM card(
GSM850/900/1800/1900MHz
) to the slot.
Connect the power supply,Switch ON.
for confirm, for mistake reminding on the LCD display when setting.
Confirming T2 SIM Card number:
Setting
8# T2’s SIM CarnumberSetting
T2 will get mobile operator‟s date and time according to the SIM Card number,LCD will correct and display the real date&time after few mins when setting done.If T2 can‟t get date&time automatically, please try to remove or add the country code,like 008613510150873 instead of 13510150873.
For example,setting the T2‟s SIM card (13510150873) number:
Fast dial numbers:
Fast dial buttons position
SettingFast dial buttonPhone numberSetting
For example,setting the Police station number (999):
LCD display:
1 2
3 4
5 6
7 8
Alarm R eceiver’s phone number:
Setting
Receiver’s position(1~5)#Phone number#Function code(0~2) Setting
5 alarm SMS & Call receivers supported, the postion number from 1~5.
Function code:
0: call this number
1: send alert SMS text to this number
2: send alert SMS text and call to this number
For example,setting the 1 st
position number(0086952), this number can receive alert SMS & Call.
Page 7 of 15 Ver 1.0
T2 --- GSM Elderly Care Alarm System
Notice:
Stay/Away,wireless sensor‟s battery low power,T2 back up battery low power,AC/DC power lost/recovery,High/Low temperatuer alarm,Bedtime monitoring SMS send to the 1 st
& 2 nd
receiver only,so the 1 st
& 2 nd
receiver should be mobile phone and select the function code as 1 or 2.
Temperature alarm threshold
Setting6 # high thresholdSetting (Default: High
—99, disable this function.)
Setting7 # low threshold Setting (Default: Low
—00,disable this function)
High/Low threshold value: 2 digits only.
For example,Setting high threshold as 32 degree.
Alarm clocks (1~3)
Setting100#hhmmSetting
Setting200#hhmmSetting
Setting300#hhmmSetting
For example, setting the 1 st
alarm clock at 08:30am.
Delete alarm clock:
Setting100#Setting
Setting200#Setting
Setting300#Setting
Alarm audible time(0~240)
Setting9#audible timeSetting
T2 will make audible alarm and flash on LCD when alarm occurance.Alarm audio sounds 20 seconds and stop 2 seconds inteval,the totally time(0~240 seconds, default:60).
For example, setting the audible alarm as 30 seconds.
White list setting
Whilte list: the numbers of fast dial (1~8) and alarm receivers(1~5).
Setting all numbers can call in to the T2 (default): Setting0#0Setting
Setting white list numbers can call in to the T2 only: Setting0#1Setting
Reset to factory mode
Setting000001#
Caution: The operation will RESET T2 to factory mode! All of your settings will lost.
Page 8 of 15 Ver 1.0
T2 --- GSM Elderly Care Alarm System
5.Add wireless sensors
Add wireless sensors step
Settingzone number(01~16)#zone type(1~6) Trigger the sensorSetting
For example, add one fall detecct sensor to zone #3:
Trigger the sensor
Zone types explaination
1: SOS alarm
2: Smoke alarm
3: Gas alarm
4: CO alarm
5: Watchdog monitoring
6: Bed/Get up time monitoring
Watchdog zone time setting
Two period time monitoring can be setting for a same watchdog zone.
Setting400#Zone number#Start time#End timeSetting (Default 0000#0000, disable.)
Setting500#Zone number#Start time#End timeSetting (Default 0000#0000, disable.)
For example,add one door sensor on the zone #5 (main gate) and setting the time at 07:00~09:30 and
16:00~17:30,if the main gate not opened on the above duration,T2 will send alert SMS text to the 1 st
and
2 nd
receiver.
Bedtime/Get up monitoring zone time setting
T2 can install wireless s ensors to monitor the elderly‟s sleeping(bed)/wake up(get up) time.
Bedtime period: Setting400#Zone number#Start time#End timeSetting
Get up time period: Setting500#Zone number#Start time#End timeSetting
(Default 0000#0000, disable.)
For example, install one PIR sensor on the bed room‟s door frame(Zone #6),setting the bedtime at
21:00~22:30, and get up time at 06:00~08:30,T2 will record the latest movement detection between
21:00~22:30,ie.: at 22:10, then T2 will send notify SMS text “Mom went to bed at 22:10” to the 1 st
receiver.
And if Mom get up and the first time she walk through the door at 07:30am, then T2 will send notify SMS text “Mom got up at 07:30 ” to the 1 st
receiver.
If the PIR sensor didn‟t detect any movement dring 21:00~22:30, and 06:00~08:30,T2 will send alert
SMS text “Mom still not went to bed” at 22:31, and “Mom still not get up” at 08:31 to the 1 st
& 2 nd
receiver.
Notice:
The different between “Watchdog zone” from “Bed/Get up time monitoring zone” is:
“Bedtime/Get up time monitoring zone” will send notify SMS text of the latest sensor’s trigger during the period to the 1st receiver after time out.
Page 9 of 15 Ver 1.0
T2 --- GSM Elderly Care Alarm System
6. How T2 works for elderly?
Push-to-Talk with families
Keep the origin design icons or stick a easy recognized photo on the buttons, just push these buttons then make a phone call with families
Push-to-Ask for help
Keep the origin design icons or stick a easy recognized photo on the buttons, just push these buttons then make a phone call with Doctor,Police station,Taxi/Cab service and neighbor/community service.
SOS alarm when under emergency situation
Make phone call
Push the SOS button for 3 seconds,T2 will send SOS alert SMS text and make a phone call to receivers for asking emergency help.
Other Wireless SOS button or fall detectors optional.
Press the keypad for make a phone call,just like a regular telephone set.
Press for answer the call in, press for end calls.
Press to erase the last number if made mistake.
24hours safety guard
When smoke,gas,CO or water flood detected,T2 will make audible alarm,send alert SMS text and call to the receivers/Call center/Firefighting or other CMS system.
Alarm clocks
T2 will make audible alarm and flash on LCD according to the timing setting.Alarm audio sounds 10 seconds and stop 2 seconds,repeat 5 times or stoped by end button .
Audio volume(1~5) can be adjust by and ,(the same volume for phone call,audible alarms).
Daily life care
T2 will send alert SMS text if no activities detected by PIR/Door sensors during the watchdog time period.
For example,install one door contact sensor on the main gate,setting time period at 16:00~18:00pm,if the main gate not opened during that time,T2 can send alert SMS to receivers.
Page 10 of 15 Ver 1.0
T2 --- GSM Elderly Care Alarm System
Bedtime/Get up care
Under the status, T2 will send notify SMS text of the
“bedtime” and “get up time” to the 1 st receiver.
For exampl e, install one curtain PIR sensor on Mom‟s bed room(door frame),setting the bedtime at
21:00~22:30, and get up time at 06:00~08:30,T2 will record the latest movement detection between
21:00~22:30,let‟s say at 22:10, then T2 will send notify SMS text “My bedtime: 22:10,good nite:)” to the
1 st
receiver at 22:30.
If Mom get up and the first time she walk through the door at 07:30am, T2 will send notify SMS text
“Good morning, I get up at 07:30” to the 1 st
receiver at 07:30.
If the PIR sensor didn‟t detect any movement on 21:00~23:00, and 06:00~08:30,T2 will send alert SMS text “I didn't go to sleep yet” at 22:31, and “I didn't get up yet.” at 08:31 to the 1 st
and 2 nd
receiver.
This unique function designed for take care elderly‟s health status on the evening and morning, in case of any unexpected situation, receviers can get notify SMS text and need to take care about
“are there anythin g OK”,”why mom still not get up” or “why she still not go to bed?” etc.
Stay/Away care
Press when away home, T2 will send notify SMS text
“I'm leaving home now.” to the 1 st
and 2 nd receiver,to let them know that elderly away home at that time.
T2 will send notify SMS text
“I'm at home now
.
” to the 1 st
and 2 nd
receiver when elderly back to home and pressed the button, to let them know that the elderly back home safety.
If the receiver get notify SMS text of “I'm leaving home now.” but didn‟t get SMS text of “I'm at home
now
.
” after few hours,for example:received the SMS text “I'm leaving home now.” at 16:00 but didn‟t received SMS text “I'm at home now
.
” till 22:00,then receivers should call to T2 or mobile numbers to check if elderly forgot press the Stay button or really didn‟t go back yet.
Temperature monitoring
T2 send alert SMS text to receivers when temperature higher/lower than threshold more than 10mins.
Other care
T2 will send alert SMS text to the 1 st
and 2 nd
receivers when AC/DC power lost (more than 30mins) and recovery, back up battery low power,wireless sensor‟s battery low power(if have).
Page 11 of 15 Ver 1.0
T2 --- GSM Elderly Care Alarm System
7. Setting & Operation by SMS commands:
T2 can setting by SMS commands with password protection remotely.
* The SMS commands should with Password, 1234 is the default password on below context,please change it to new password if you had changed already.
* The command body PU,EE,etc must be Caps Lock.
* No space on the SMS commands, the space on command list just for reading purpose.
Change Password
1234PU new password
T2 return: This is the New Password, please remember it carefully.
E.g.:
1234P 6666
for change the new password to 6666.
Modify the Fast dial phone numbers.
1234A position(1~8) T phone number
For example,modify the Policy station‟s number to 999:
E.g.:
1234A 6 T 999
Inquiry fast dial phone number:
1234A
Remove fast dial phone number:
1234A position(1~8)
Modify the Alarm receiver’s phone numbers.
1234B position(1~5) T phone number A function code(0~2)
*Function code: refer to page 7
“Alarm Receiver’s phone number”
For example,modify the
1ST receiver‟s phone number to 0086952,this number can receive SMS and call.
E.g.:
1234B 1 T 0086952 A 2
Inquiry alarm receiver‟s phone number:
1234B
Remove alarm receiver‟s phone number:
1234A position(1~5)
Modify the alarm content of zones.
1234M zone number(00~16) alarm content
E.g.:
1234M
01Smoke Fire alarm!
Page 12 of 15 Ver 1.0
T2 --- GSM Elderly Care Alarm System
Modify the Alarm Clocks.
For example,modify the 1ST alarm clock to 08:30
1234C position(1~3) hhmm
Inquiry alarm clocks:
1234C
Remove alarm clock:
1234C position(1~3)
Inquiry the T2 status.
1234EE
T2 return:
I'm at home; / I„m away; (Elderly at home or away home)
External AC Power OFF/ON (AC power status)
GSM Signal:** (GSM signal range 1~31, lower than 14 means signal weak)
Temp:**degree; (Celsius)
IMEI: ****************
(GSM module‟s IMEI code)
8.※GPRS data Parameter Setting※
For engineer and remote server system only
Please ignore this part if the total quantity of T2 should me monitoring less than 200pcs
APN(call your mobile operator to ask the Access Point Name, private APN supported)
1234APN apn name#user#password
Eg: 1234APN
everywhere
*
eesecure
*
secure
#
(the example “APN name:everywhere, user: eescure, password: secure” supported by Orange UK)
CMS Server IP address and server port
1234IP server IP address P server port
Eg: 1234IP 175.164.49.20
P 4005
T2 send “
I'm leaving home now.
” through GPRS data to server system when Away button is pressed.
T2 send “
I'm at home now.
” through GPRS data to server system when Stay button is pressed from Away status.
Alarm process:
Alert SMSGPRS data to Server systemAlarm dial
GPRS upload to Server system depends on the alarm events(trigger) automatically,GPRS Data off line when data send complete. T2 can't receive data from server system.
GPRS data following the Contact ID (SIA DC-9) protocol.
Page 13 of 15 Ver 1.0
T2 --- GSM Elderly Care Alarm System
9. SMS Content list
Events
Big SOS button pressed
SOS Help!
I'm leaving home now.
Alert SMS text Description
Zone number: 00
Away button pressed
Stay button pressed
AC/DC power lost
AC/DC power recovery
Wireless zone #1 alarm
Wireless zone #2 alarm
Wireless zone #3 alarm
I'm at home now.
Alert: External AC power lost!
Notice: External AC power recovery!
SOS Help! Fall down detector alarm!
Alarm: Smoke detected!
Alarm: Gas detected!
Alert when AC/DC power lost more than 30mins
T2 back up battery low power
High temeprature alarm
Alert: Main panel's battery low power!
Alert: High temperature alarm!Current Temp: **C
Low temeprature alarm
Alert: Low temperature alarm!Current Temp: **C
Temperature back to normal value
Notice:Temperature back to normal.Current Temp:**C
My bedtime: **:**,good nite:)
Sensor‟s latest trigger time
Bedtime monitoring
I didn't go to sleep yet. If no trigger
Good morning, I get up at **:**
Sensor‟s first trigger time
Get up time monitoring
I didn't get up yet. If no trigger
For EM-90 (*optional)
For SM-100 (*optional)
For GL-100A (*optional)
For CO detector (*optional)
For PIR/Door (*optional)
F or bed/get up…
For WL-100 (*optional)
Wireless zone #4 alarm
Wireless zone #5 alarm
Wireless zone #6 alarm
Alarm: CO detected!
Alert: Watchdog zone!
Alarm: Water flooding!
Wireless zone #7 alarm
Wireless zone #8 alarm
Wireless zone #9 alarm
Wireless zone #10 alarm
Wireless zone #11 alarm
Wireless zone #12 alarm
Wireless zone #13 alarm
SOS Help! Wireless pedant alarm!
SOS Help! Wireless wrist button alarm!
SOS Help! Wireless panic button alarm!
Zone 11 alarm!
Zone 12 alarm!
Zone 13 alarm!
Wireless zone #14 alarm
Wireless zone #15 alarm
Zone 14 alarm!
Zone 15 alarm!
Wireless zone #16 alarm
Zone 16 alarm!
Wireless sensor’s battery low power Alert: Zone xx detector low power!
For EM-60 (*optional)
For EM-70 (*optional)
For EM-100 (*optional)
For other optional sensors
For other optional sensors
For other optional sensors
For other optional sensors
For other optional sensors
For other optional sensors
Reserve function.
Page 14 of 15 Ver 1.0
T2 --- GSM Elderly Care Alarm System
10. Quick Setting Menu
Function Example
Confirming T2 SIM Card number
T2 SIM card number:1351015
Fast dial number
Alarm Receiver‟s phione number
Setting the Police station number (999)
Setting the 1 st
position receiver number: 0086952, can receive alarm
SMS and Call
High Temperature alarm
Setting high threshold as 32 degree.
Low Temeprature alarm
Setting high threshold as 20 degree.
Alarm Clocks Setting the 1 st
alarm clock at 08:30am
Buttons
Alarm audible time Setting audible alarm 30 seconds
White list
Add sensors
Setting all numbers can call in to the
T2 (default)
Setting white list numbers can call in to the T2 only add one smoke sensor to zone #3
Trigger the sensor
Watchdog zone time 1
Watchdog zone time 2
Bedtime
Get up time
Setting monitoring period at
0700~0930am for zone 5
Setting monitoring period at
1600~1730pm for zone 5
Setting bedtime period at
21:00~22:30 for zone 6
Setting get up time period at
06:00~08:30 for zone 6
11. Warranty
1) This system is warranted to be free of defects in material and workmanship for one year.
2) This warranty does not extend to any defect, malfunction or failure caused by abuse or misuse by the
Operating Instructions. In no event shall the manufacturer be liable for any alarm system altered by purchasers. www.GsmAlarmSystem.com