Tooling Solutions for the Power Utility & Construction Industries.
CUSTOM
GROUNDING SETS
& JUMPERS
MADE TO ORDER FAST . . .
Select from a wide range
of Cable Types and Sizes,
Ferrules, Clamp Styles, and
Custom Combinations
RELIABLE EQUIPMENT & SERVICE CO., INC. • 92 Steamwhistle Drive • Ivyland, PA 18974
Phone: 800-966-3530 • Fax: 215-357-9193 • Visit us on the web at www.Reliable-Equip.com
TYPICAL GROUND
ASSEMBLY
Ground Assembly shown with:
1-1/2 in.
“C” Type Clamp
2/0 Threaded Ferrule
Orange Salcor
Strain Relief
2/0 Yellow
Cable
Consult your Reliable
representative for available
grounding options.
HOW TO ORDER A GROUNDING SET
Proper selection of each part of a grounding
set is important in filling the requirements
of your application:
ASTM Type I with black or yellow
elastomer jackets for temperatures from
-40O F (-40O C) through +194O F (+90O C).
1. Clamps
ASTM designation for Type, Class, and Grade.
Clamp Style (“C” Type, Duck Bill, Flat, or Bus)
Clamp Size. (min. & max. capacity)
Manner of Application (Glove or Hot Stick)
ASTM Type III with clear thermoplastic
jacket for temperatures from +14 O F
(-10O C) through +140O F (+60O) should
be used only in well-ventilated areas.
This translucent option recommended
for stress relief and inspection of cable
2. Ferrules
Size - Must match required Ground Cable
Material - Copper or Aluminum.
Plain or Threaded - Match clamp selection
3. Cable
Length required to reach application distances.
4. Shrink Tubing or Strain Relief
USED WITH CONFIDENCE AROUND THE WORLD
92 Steamwhistle Drive • Ivyland, PA 18974
Phone: 800-966-3530 Fax: 215-357-9193
Visit us on the web at www.Reliable-Equip.com
2260
1610
2115
R15-2/0
21353
2022
2750
RELIABLE - R15 SERIES - INSULATED JUMPER SETS
Reliable Equipment offers a full range of preassembled Jumper Cables for bypassing
work areas where equipment is under repair, the line is being upgraded, and for making
temporary or other emergency repairs. Sets can be assembled to meet any of your
conductor, AMP, line range, and cable length requirements from 1/0 to 4/0 in 15kV sets.
Jumper Cable - 5/15 kV Dual Rated
Part
Size
AMP
R15-1/0
1/0
260
Approx.
Cable O.D.
1,000
R15-2/0
2/0
300
1,055
R15-4/0
4/0
400
1,165
Ferrules (unshrouded) - (sold in pairs)
Part
Cable
Stud
AMP
2023
1/0
5/8"-11 NC
400
2024
2/0
5/8"-11 NC
400
2025
4/0
5/8"-11 NC
400
How to order Jumper Sets
Jumper Clamps - (sold in pairs)
Part
Range
AMP
Head Style
2115
#6 SOL
to 954 ACSR
400
Clear Plastic
2270
#6 SOL
to 954 ACSR
400
H/D Salcor
Specify cable size, length, and clamp style
Ex: R15-1/0 x 12-2270
Other kV size cables and clamps styles
available upon request.
Contact Reliable for more information.
SALCOR R INSULATED CLAMPS
“Rubber covered” hot bypass jumper clamps. Metal components and conventional
electrical/mechanical design.
Thermosetting Elastomer Handle, 11.5" O.A.L. with 1.5" I.D., 7.5" below Hand Guard.
Part
Main Line Range
Description
Max. Amps
2260
477 MCM, (30x7) ACSR
to #6 Sol., .883"-.162" Dia.
Clamps, Insulated Jumper (Pair) Only
400
2270
954 MCM, (36x1) ACSR
to #6 Sol., 1.14"-.162" Dia.
Clamps, Insulated Jumper (Pair) Only
400
CLEAR PLASTIC INSULATED JUMPER CLAMPS
Field application is rubber gloves installed for temporary jumper service on distribution
lines. Large head with a moderate size handle. Compact, lightweight clamp.
Polycarbonate (Lexan R) handle, 11.5" long, 7.5" below Hand Guard.
Heat Deflec. Temp. ASTM D648 270 O F at 264 psi.
Part
Main Line Range
Description
Max Amps.
1785
477 MCM, (30x7) ACSR
Clamps, Insulated Jumper (Pair) Only
to #6 Sol., .883"-.162" Dia.
400
2115
954 MCM, (36x1) ACSR
Clamps, Insulated Jumper (Pair) Only
to #6 Sol., 1.14"-.162" Dia.
400
PLASTIC INSULATED HOT BYPASS JUMPER CLAMPS
Self lubricating sintered bronze thrust bearing efficiently converts torque to main
line contact pressure for minimum electrical resistance. Blunted points on the handle
provide optimum grip, resists impact and will not soften with overloads.
11" fiberglass reinf. thermosetting plastic handle. 6.75" below Hand Guard. Heat
deflec. temp. ASTM D648 600 O F + at 264 psi.
Part
Main Line R ange
Description
1610
954 MCM, (36x1), ACSR
to #6 Sol., 1.14"-.162" Dia.
Clamps, Insulated Jumper (Pair) only
FERRULES FOR JUMPER CLAMPS
Manufactured of 99.5% pure copper
and are tinplated to prevent galvanic
action between the dissimilar metals.
5 / 8 - 11 N C t h r e a d s . D e s i g n e d f o r
continuous service on either stick or
glove installed jumpers.
Two ferrule styles are available.
Shrouded ferrules should only be used
on “glove” installed high voltage jumpers,
and not on “stick” installed insulating
jumpers which have cable support clamp
and strain relief system.
The shrouded ferrule is compressed on
both the conductor and the insulating
jacket of the high voltage EPR cable,
reducing bending stresses at the
termination.
Unshrouded cable ferrules work with
all jumper & grounding cables regardless of jacket thickness.
Max. Amps
400
Shrouded Jumper Cable Ferrules
Part / Pair
Not Inst.
Installed
Jumper
Cable Size
2012
2012A
2-15kV EPR
2013
2013A
1/0-15kV EPR
2014
2014A
2/0-15kV EPR
2015
2015A
4/0-15kV EPR
21353
21353A
1/0-25kV
21354
21354A
2/0-25kV
21355
21355A
1/0-35kV
21356
21356A
2/0-35kV
Unshrouded Ferrules
Part / Pair
Not Inst.
Installed
Jumper
Cable Size
2022
2022A
#2
2023
2023A
1/0
2024
2024A
2/0
2025
2025A
4/0
2750 - CONNECTOR LINK FOR INSULATED JUMPERS
Developed recently to connect two insulated jumpers in the field for longer jumper
length. The assembly can be wrapped with a small rubber insulating
blanket. 400 Amp Max.
HOW TO ORDER A GROUNDING SET
In addition to the specifying criteria above,
each part of a grounding set requires
certain choices:
TYPICAL CONFIGURATION
1. Clamps
ASTM designations for Type, Class, and
Grade given for clamps in this section.
2. Ferrules
Copper or aluminum. Plain or threaded.
3. Cable
Length required to reach application
distances.
ASTM Type I with black or yellow
elastomer jackets for temperatures from 40O F (-40O C) through +194 O F (+90O C).
ASTM Type III with clear thermoplastic
jacket for temperatures from +14 O F
(-10 O C) through +140O F (+60O) should
be used only in well-ventilated areas.
4. Support Stud
This option recommended on only one
clamp to help control lifting the set to the
first clamp attachment point.
INSTALLATION
5. Shrink Tubing
Chance videotapes and technical manuals
- provide more details on proper
installation. Consult your Reliable
representative for any assistance.
This translucent option recommended
for stress relief and inspection of cable
strands between ferrule and jacket.
INFORMATION
Several installation training aids are available
on request.
OVERHEAD DISTRIBUTION
GROUNDING SET WITH
PRESSURE-TYPE TERMINALS
This complete set of ground clamps,
cable, and accessories gives all of the
equipment needed for many types of
distribution structures in one easy to
use kit. The jumper terminals are
factory crimped to the grounding cable.
The kit comes with ten C600-2276 clamps
so that it can be used on conductors
ranging from #8 to 1033 kcmil ACSR.
This kit was designed for use on the
following types of structures:
7.2/12.5 kV ......... A1 through C24
14.4/24.9 kV ....... VA1 through VC9-3
46 kV .................. TP1 through TP5
69 kV .................. TS1 through TS3-2
The table below lists the various components completely assembled in the
Distribution Grounding Set. (See diagram above for application)
T600-0641 - Overhead Distribution Grounding Set* consists of:
Item
Description
Quantity
Information
A
Serrated jaw, "C" Clamp
No. C600-2276
10
For Plain Plug
Terminals
B
Ground Cluster Support
1
T600-1549
C
#2 Copper Ground Cable
No. 6499
60 ft.
3 Cables 6 ft. long
1 Cable 12 ft. long
1 Cable 30 ft. long
D
#2 Plain Plug Ferrules
10
Cat. No. C600-2626
E
Clamp Support Stud
3
Cat. No. G3626
F
Screw Ground Rod
1
Cat. No. G3370
CLUSTER SUPPORT, 1-TERMINAL TYPE
Conveniently hangs grounding sets on the
pole to facilitate lifting clamps - one at a time to
the conductors. Accepts plain ferrules on #2 to
4/0 grounding cable. Copper bar length is 11".
Part
Description
Weight
C600-0152
Ground Cluster Support
9-1/2 lb.
C600-2271
C600-1754
C600-2275
Bronze body, Smooth jaws,
Bronze eyescrew with fine threads,
Drilled terminal, no threads
Aluminum body, Smooth jaws,
Bronze eyescrew with Acme threads,
5/8-11 UNC terminal threads
Aluminum body, Smooth jaws,
Bronze eyescrew with Acme threads,
Bronze pressure-type terminal
C600-2276
C600-2281
C600-2255
Aluminum body, Serrated jaws,
Bronze eyescrew with Acme threads,
Bronze pressure-type terminal
Aluminum body, Smooth jaws,
Bronze eyescrew with Acme threads,
Bronze pressure-type terminal
Aluminum body, Smooth jaws,
Bronze eyescrew with Acme threads,
Drilled terminal, No threads
C-TYPE GROUNDING CLAMPS
Part No.
C600-2271
C600-1754
C600-2275
C600-2276
C600-2281
C600-2255
ELECTRICAL RATINGS
Cont. Current (AMPS)
400
350
400
400
400
400
Fault Current - 15 Cycles (AMPS)
43,000
28,000
43,000
43,000
43,000
43,000
Fault Current - 30 Cycles (AMPS)
30,000
20,000
30,000
30,000
30,000
30,000
MECHANICAL RATINGS
Recommended Torque (in.-lb.)
350
250
250
250
250
250
Main Line Range - Max.
1033 kcmil
ACSR
(1.25")
750 kcmil
Str. Cu.
636kcmil
ACSR
(.998")
1033 kcmil
ACSR
(1.25")
1033 kcmil
ACSR
(1.25")
2" O.D.
Bus
2" O.D.
Bus
Main Line Range - Min.
#6 Sol. Cu.
(0.162")
#8 Sol. Cu.
(0.128")
#8 Sol. Cu.
(0.128")
#8 Sol. Cu.
(0.128")
#6 Sol. Cu.
(0.162")
#6 Sol. Cu.
(0.162")
Jumper Range - Max
4/0 Grd. Cable 2/0 Grd. Cable 4/0 Grd. Cable 4/0 Grd. Cable 4/0 Grd. Cable 4/0 Grd. Cable
w/ Thrd. Stud w/ Thrd. Stud w/ Plain Plug w/ Plain Plug w/ Plain Plug w/ Thrd. Stud
Jumper Range - Min.
#2 Grd. Cable #2 Grd. Cable #2 Grd. Cable #2 Grd. Cable #2 Grd. Cable #2 Grd. Cable
w/ Thrd. Stud w/ Thrd. Stud w/ Plain Plug w/ Plain Plug w/ Plain Plug w/ Thrd. Stud
Weight, Each
ASTM Designation
2 lb.
1 lb.
1-1/4 lb.
1-1/4 lb.
2 lb.
1-3/4 lb.
Type I
Class A
Grade 5
Type I
Class A
Grade 3
Type I
Class A
Grade 5
Type I
Class B
Grade 5
Type I
Class A
Grade 5
Type I
Class A
Grade 5
SALISBURY
4388
4200
9985
9984
4187
1895
4255
1893
“C” STYLE GROUNDING CLAMPS
Part No.
Construction Material
Jaw Style
Thread
4200
4388
9985
4187
Bronze
Smooth (U)
Curved (L)
“V”
Aluminum
Smooth (U)
Curved (L)
Acme
Bronze
Smooth (U)
Flat (L)
Acme
Bronze
Serrated (U)
Curved (L)
Acme
ELECTRICAL RATINGS
Continuous Current
300 RMS Amps
60 Hz
400 RMS Amps
60 Hz
MECHANICAL SPECS
Main Line Range - Max.
Main Line Range - Min.
Maximum Cable Dia.
Minimum Cable Dia.
Weight, Each
ASTM Designation
477 MCM
18 x 1 ACSR
#6
.81 in.
.12 in.
1.0 lb.
Class A
Grade 3
795 MCM
26 x 7 ACSR
#6
1.12 in.
.12 in.
1.1 lb.
Class B
Grade 5
1033.5 MCM
26 x 7 ACSR
#6
1.12 in.
.12 in.
1.9 lb.
Class A
Grade 5
1590 MCM
26 x 7 ACSR
#8
1.12 in.
.12 in.
1.19 lb.
Class B
Grade 5
“C” STYLE GROUNDING CLAMPS 1.25” and 1.5” Sizes
Part No.
Construction Material
Jaw Style
9984
4255
1895
1893
Bronze
Smooth (U)
Flat (L)
Bronze
Smooth (U)
Curved (L)
Aluminum
Smooth (U)
Flat (L)
Aluminum
Serrated (U)
Flat (L)
ELECTRICAL RATINGS
Continuous Current
400 RMS Amps / 60Hz
MECHANICAL SPECS
Main Line Range - Max.
Main Line Range - Min.
Maximum Cable Dia.
Minimum Cable Dia.
Weight, Each
ASTM Designation
1035.5 MCM
#6
1.25 in.
.16 in.
2.2 lb.
Class A
Grade 5
1035.5 MCM
#6
1.25 in.
.16 in.
2.2 lb.
Class B
Grade 5
1431 MCM
#6
1.5 in.
.16 in.
1.7 lb.
Class A
Grade 5
1431 MCM
#6
1.5 in.
.16 in.
1.8 lb.
Class B
Grade 5
20882
21075
1923
1921
4377
4295
SALISBURY
“C” STYLE GROUNDING CLAMPS
2” SIZE W/ CURVED LOWER JAW
Part No.
Construction Material
Jaw Style
21075
20882
Aluminum
Smooth
Aluminum
Serrated
Thread
Acme
ELECTRICAL RATINGS
Continuous Current
400 RMS Amps / 60Hz
MECHANICAL SPECS
Main Line Range - Max.
Main Line Range - Min.
Maximum Cable Dia.
Minimum Cable Dia.
Weight, Each
ASTM Designation
3000 KCM
#6
2 in.
.16 in.
2.0 lb.
Class A
Grade 5
3000 KCM
#6
2 in.
.16 in.
2.1 lb.
Class B
Grade 5
Available
Perminently
Mounted on
1.25 in. x 6 ft.
Hot Stick.
2.4” SIZE W/ FLAT LOWER JAW - ACME THREAD
Part No.
Construction Material
Jaw Style
1923
4377
1921
4295
Aluminum
Smooth
Aluminum
Smooth
Aluminum
Serrated
Bronze
Smooth
ELECTRICAL RATINGS
Continuous Current
350 RMS Amps
60 Hz
400 RMS Amps
60 Hz
MECHANICAL SPECS
Main Line Range - Max.
Main Line Range - Min.
Maximum Cable Dia.
Minimum Cable Dia.
Weight, Each
ASTM Designation
2” I.P.S.
#6
2.4 in.
.16 in.
2.1 lb.
Class A
Grade 5
2” I.P.S.
#6
2.4 in.
.16 in.
2.1 lb.
Class A
Grade 5
2” I.P.S.
#6
2.4 in.
.16 in.
2.2 lb.
Class B
Grade 5
2” I.P.S.
#6
2.4 in.
.16 in.
4.1 lb.
Class A
Grade 5
SALISBURY
1793
21030
1852
1853
DUCK BILL GROUNDING CLAMPS
Part No.
1793
21030
1853
1852
Construction Material
Bronze
Aluminum
Aluminum
Aluminum
Jaw Style
Smooth
Smooth
Serrated
Smooth
Gravity
Actuated
Spring
Loaded
Spring
Loaded
Spring
Loaded
“V”
Acme
Acme
Acme
Thread
ELECTRICAL RATINGS
Continuous Current
350 RMS Amps
60 Hz
400 RMS Amps
60 Hz
MECHANICAL SPECS
Main Line Range - Max.
556 MCM
795 KCM
1033.5 MCM
1590 MCM
Main Line Range - Min.
#6
#6
#6
#6
Maximum Cable Dia.
.96 in.
1.1 in.
1.25 in.
1.66 in.
Minimum Cable Dia.
.16 in.
.16 in.
.16 in.
.16 in.
Weight, Each
1.3 lb.
1.1 lb.
1.5 lb.
1.1 lb.
Class A
Grade 4
Class A
Grade 5
Class A
Grade 5
Class A
Grade 5
ASTM Designation
SNAP-ON (DUCKBILL-TYPE) GROUNDING CLAMPS
A.B. CHANCE Part No.
G3622-1
T600-0806
ELECTRICAL RATINGS
Cont. Current (AMPS)
400
400
Fault Current - 15 Cycles
36,000
43,000
Fault Current - 30 Cycles (Amps)
25,000
30,000
MECHANICAL RATINGS
Recommended Torque (in.-lb.)
250
250
Main Line Range - Max.
566 kcmil
Cu.
900 kcmil
ACSR
(1.162")
1590 kcmil
ACSR
(1.625")
Main Line Range - Min.
#6 Sol. Cu.
(0.162")
0.5"
Jumper Range - Max
4/0 Grd. Cable 4/0 Grd. Cable
w/ Plain Plug w/ Plain Plug
Jumper Range - Min.
#2 Grd. Cable #2 Grd. Cable
w/Plain Plug w/ Plain Plug
Weight, Each
1-1/2 lb.
1-3/4 lb.
ASTM Designation
Type I
Class A
Grade 4
Type I
Class B
Grade 5
G3622-1
Aluminum body, Smooth jaws,
Bronze eyescrew with fine threads,
Bronze pressure-type terminal
T600-0806
Aluminum body, Serrated jaws,
Bronze eyescrew with fine threads,
Bronze pressure-type terminal
1814
1815
4345
9993
SALISBURY GROUNDING CLAMPS FOR FLATS, ANGLES & ROUNDS
Part No.
Construction Material
Jaw Style
1814
1815
4345
9993
Bronze
Bronze
Aluminum
Aluminum
Serrated
Serrated
Serrated
Smooth
ELECTRICAL RATINGS
Continuous Current
400 RMS Amps / 60Hz
MECHANICAL SPECS
Main Line Range - Max.
Main Line Range - Min.
Maximum Cable Dia.
Minimum Cable Dia.
Weight, Each
ASTM Designation
G3363-3SJ
1.5” Flat or Sq.
.06” Flat or Sq.
1.5 in.
.06 in.
1.7 lb.
Class B
Grade 3
32 mm dia.
1.5 mm dia.
1.25 in.
.06 in.
1.6 lb.
Class B
Grade 3
1.5” Flat or Sq.
.06” Flat or Sq.
1.25 in.
.06 in.
2.1 lb.
Class B
Grade 5
G3363-2
G3363-4SJ
C600-2231
29 mm dia.
4 mm dia.
1.6 in.
.16 in.
1.6 lb.
Class A
Grade 5
A.B. CHANCE - TOWER AND FLAT-FACE GROUNDING CLAMPS
Part No.
Construction Material
Jaw Style
Terminal
G3363-3SJ
C600-2231
C3363-4SJ
C3363-2
Alunminum
Serrated
P/T
Bronze
Serrated
P/T
Aluminum
Serrated
P/T
Bronze
Serrated
P/T
ELECTRICAL RATINGS
Cont. Current (AMPS)
400
400
400
400
Fault Current - 15 Cycles (AMPS)
25,000
43,000
25,000
25,000
Fault Current - 30 Cycles (AMPS)
25,000
30,000
25,000
25,000
250
250
250
250
MECHANICAL RATING
Recommended Torque (in.-lb.)
Main Line Range - Max.
Main Line Range - Min.
1-1/2" Flat and Angles
1/8"
1/8"
1/8"
1/8"
Jumper Range - Max
4/0 Grd. Cable
w/ Plain Plug
4/0 Grd. Cable
w/ Thrd. Stud
4/0 Grd. Cable
w/ Plain Plug
4/0 Grd. Cable
w/ Plain Plug
Jumper Range - Min.
#2 Grd. Cable
w/ Plain Plug
#2 Grd. Cable
w/ Thrd. Stud
#2 Grd. Cable
w/ Plain Plug
#2 Grd. Cable
w/ Plain Plug
Weight, Each
1-5/8 lb.
2 lb.
1-5/8 lb.
2-1/2 lb.
ASTM Designation
Type I
Class A
Grade 5
Type III
Class A
Grade 4
Type III
Class A
Grade 3
Type III
Class B
Grade 3
2680
Four Way Connector
Grounding Set
Typical
Application
Four Way Connector Grounding Set
Part No.
Qty.
ASTM
Weight
2680
Description
Four Way Connector Ground Set
21 kA 15 cycles
1
Grade 5
28 lbs.
2374A
Four Way Connector w/ Sleeves
1
1895A
1.5” Smooth Jaw Clamps w/ Sleeves
4
2427A
Double Hanger Stud
1
2402A
Contact Stud
1
2137
1/0 Cu. Cable
34 ft.
2027
Ferrules
4 pr.
2374
Four Way Connector Only
1
2374A
SALISBURY
Grounding
Products
Grade 5
1.8 lbs.
CLUSTER GROUNDING-CLAMP SETS
A.B. CHANCE - Part No.
G3405
G3803
ELECTRICAL RATINGS
Cont. Current (AMPS)
350
400
Fault Current - 15 Cycles (Amps)
28,500
36,000
Fault Current - 30 Cycles (Amps)
20,000
35,000
G34045
3-Cluster Set with C-Type
Aluminum-body clamps
MECHANICAL RATINGS
Recommended Torque (in.-lb.)
250
250
Main Line Range - Max.
400 kcmil
Str. Cu.
636 kcmil
ACSR
(.998")
566 kcmil
Cu.
900kcmil
ACSR
(1.162")
Main Line Range - Min.
#8 Sol. Cu.
(0.12")
#6 Sol. Cu.
(0.162")
Jumper Range - Max
2/0 Grd. Cable 4/0 Grd. Cable
w/ Plain Plug w/ Plain Plug
Jumper Range - Min.
#2 Grd. Cable
w/Plain Plug
#2 Grd. Cable
w/ Plain Plug
Weight, Each
4-1/2 lb.
6-5/8 lb.
ASTM Designation
Type I
Class A
Grade 3
Type I
Class B
Grade 4
IMPORTANT NOTE
Cluster Sets are furnished as shown (Right).
The center clamp is bolted to the cluster bar.
Typical configuration requires a fourth clamp and
grounding cable which must be ordered
separately. Contact Reliable for more information.
Smooth jaws, Bronze eyescrews with Acme
threads, and 3-phase Aluminum cluster
bar with Bronze pressure-type terminals.
G34045
3-Cluster Set with
Snap-On (Duckbill-type)
Aluminum-body clamps
4282
2991
4341
GROUNDING CLAMPS FOR SUBSTATION BUSES
SALISBURY - Part No.
4282
4341
2991
Construction Material
Jaw Style
Aluminum
Smooth (U)
Flat (L)
Aluminum
Smooth (U)
Flat (L)
Aluminum
Smooth (U)
Flat (L)
ELECTRICAL RATINGS
Continuous Current
400 RMS Amps / 60Hz
MECHANICAL SPECIFICATIONS
Main Line Range - Max.
Main Line Range - Min.
Maximum Cable Dia.
Minimum Cable Dia.
Weight, Each
ASTM Designation
6.12” I.P.S.
Adj.
6.62 in.
4.0 in.
6.9 lb.
Class A
Grade 5
Allows for variable angle accessibility. This system is compact and
lightweight. There are fixed grounding points on the socket clamp.
21190 - Socket Clamp - Made from bronze alloy, has a 1 inch
socket and a 5/8”-11 UNC threaded bore boss.
21191
21192
24087
21228
24082
Part No.
Description
ASTM
Cont. Current
Wt. Ea.
21190
Socket Clamp W/
Strain Relief Sleeve
Grade 5
400
1.2 lbs.
Long and Short Ball Stud, and the offset NEMA Pad Ball Studs are
made from a Tin-Plated Copper Alloy. They each have a 1inch ball.
THREADED SHORT AND LONG BALL STUD - The short stud is used
conventionally, while the long stud may also be used with “C” or
Duckbill clamps that have a jaw width of 2.75 inch or less.
1/2”-13 UNC x 2” TH, 300 in. lbs. recommended installation torque.
OFFSET NEMA PAD BALL STUD - Has the standard bolt hole spacing
and is available in both long and short lengths.
INTERNAL THREAD BALL STUD - Is tapped for a 1/2-13 UNC bolt
having a length of at least 1 inch.
Part No.
Offset
NEMA Pad
Ball Stud
shown with
“C” Type
Gr. Clamp
3” I.P.S.
#6
3.5 in.
1.6 in.
2.9 lb.
Class A
Grade 5
BALL AND SOCKET GROUNDING SYSTEM
21190
21236
3” I.P.S.
1.5” I.P.S.
3.5 in.
1.75 in.
2.8 lb.
Class A
Grade 5
Description
Dimensions
Wt. Ea.
21191
Ball Stud Short
4.38 Inch
.53 lb.
21192
Ball Stud Long
6.13 Inch
.81 lb.
21228
Offset NEMA Pad Short
5.13 in. x 1.5 in.
.84 lb.
24087
Offset NEMA Pad Long
7 in. x 1.5 in.
1 lb.
24082
Internal Thread Ball Stud
21236
Cover for Ball Stud
4 inch
.54 lb.
.09 lb.
UNDERGROUND DISTRIBUTION GROUNDING SETS
TRANSFORMER GROUNDING SETS
Each set includes an orange-jacketed elbow for the
voltage-class indicated below, 6 feet of 1/0 copper
grounding cable with clear jacket, and bronze
grounding clamp T600-0466.
Fault current rating for each set: 10,000 amps for 10 cycles
Part No.
Description
Wt.
C600-0729
15 kV Single-0 Transformer Grd. Set
4 lb.
T600-2131
25 kV Single-0 Transformer Grd. Set
6 lb.
C600-1927
35 kV Single-0 Transformer Grd. Set
8 lb.
Pre-assembled for
Single-Phase or Three-Phase
Padmounted Transformers
Optional Storage Bag # T600-0865.
GROUNDED PARKING STAND
This set provides a grounded surface for the jacketed
elbow after it is removed from the transformer bushing
and tested to determine if it is de-energized. Set includes
bronze ground clamp and 4 ft. of 1/0 yellow ground cable.
Fault current rating for each set: 10,000 amps for 10 cycles
Part No.
Application
Wt.
T600-0730
15 kV
7 lb.
T600-2124
25 kV
8 lb.
Pre-assembled for
Padmounted Transformers
Optional Storage Bag # T600-0865.
TEMPORARY GROUNDING SET
Each of these sets consists of a three-way terminal
block assembly, three 6-ft. lengths of 2/0 copper
ground cable with clear jacket, a ground clamp, and
three orange elbows.
Fault current rating for each set: 10,000 amps for 10 cycles
Part No.
Application
Wt.
C600-0759
15 kV
14.5 lb.
T600-2132
25 kV
15 lb.
Pre-assembled for
3-Phase Switches and
Transformers
Optional Storage bag # T600-0865.
TEMPORARY GROUNDING SETS
C-Clamp or Ball-Stud Set includes a three-way copper
terminal block, four bronze ground clamps and three 6’
lengths of 2/0 copper clear-jacket ground cable with
threaded-stud copper ferrules. C-clamps are T600-0466.
Ball-studs and clamps are C600-2102 and C600-2100.
Fault current ratings: 37,000 amps for 15 cycles
26,000 amps for 30 cycles
Part No.
Description
Wt.
C600-0758
C-Clamp Live-Front Grd. Set
15 lb.
Optional Storage bag # T600-0865.
Pre-assembled for Live-Front
Switches and Transformers
Shrouded Ferrules overlap the grounding
cable jacket for stress relief to the terminal.
Two crimps secure the ferrule to the bare
strands and one crimp applies the jacket.
Unshrouded Ferrules are available with
shrink tubing that overlaps the bare cable
conductor and jacket for stress relief.
Available factory-installed in pairs on any
cable length or as individual units. Ferrules
install with a hydraulic crimping tool.
Copper Grounding Cable - Jacketing is
smooth abrasion, weather and oil resistant
(Meets applicable ASTM Specs). AWG size
is marked approximately every 4 feet.
Yellow and black jackets are T-prene rubber
compound with a recommended low
temperature of -20O F. Clear jackets (allow
visual inspection) are UV-inhibited PVC with a
recommended low temperature of 0 O F.
Extra-flexible cables, because of their extrafine strands, require termination ferrules when
used with ground clamps.
Either aluminum or copper ferrules may be
used with copper cable.
PART
A.B. CHANCE
SALISBURY
SIZE
AWG
APPROX WT.
*(lb./1,000 ft.)
Yellow-Jacket Copper Cable
Unshrouded Threaded Ferrules
For tapped or drilled terminals.
P600-1593 - Clear Heat-Shrink Tubes
provide corrosion-inhibitor by excluding
moisture and stress-relief for cable jacket
and ferrule-to-stranding connection.
S6116
2136
2
280
S6117
2137
1/0
425
S6118
2138
2/0
520
S6119
2139
4/0
760
Clear-Jacket Copper Cable
SALISBURY
FERRULE (PR.)
S6449
2128
2
289
S7568
2129
1/0
520
AWG
ALUM.
CU.
S6450
2133
2/0
546
C600-1662
#2
2026
2022
S6451
2288
4/0
841
C600-1663
1/0
2027
2023
C600-1664
2/0
2620
2024
C600-1665
4/0
2640
2025
A.B. CHANCE
FERRULE (EA.)
CABLE
SIZE
ALUMINUM
Black-Jaacket Copper Cable
* Shrouded
Pressure Type
Terminal
S3713
2636
2
280
S3715
2637
1/0
425
S3712
2638
2/0
510
S3714
2639
4/0
760
* Strand count may vary with manufacturer.
Ferrules for Pressure Type Grounding-Clamp Terminals
Application
Unshroude Ferrules
Shrouded Ferrules
Burndy
Die # or
Equivalent
Cable
Size
AWG
Part #
1 Pr. Copper
SALISBURY
Part #
Ea. Copper
A.B. CHANCE
Part #
1 Pr. Copper
SALISBURY
Part #
Ea. Aluminum
A.B. CHANCE
U165
#2
24420
C600-2614
24424*
C600-2614*
U165
1/0
24421
C600-2615
24425*
C600-2614*
U165
2/0
24422
C600-2616
24426*
C600-2614*
U166
4/0
24423
C600-2617
24427*
C600-2614*
NEW
for 2009
Shown with
Optional Ground
Assembly
R-T-GRND
TEMPORARY SCREW
GROUND ROD
RELIABLE’s R-T-GRND Temporary
Screw Ground Rod will provide a ground
where a system ground is not available.
When installed, the 6’ spiraled ground rod
developes less resistance than straight
ground rods. (Actual resistance values
depend upon soil properties)
The reusable Ground Rod is copper clad.
The helix (spiral), handle and wing nut
are bronze.
Custom Assemblies are available.
Consult your RELIABLE represntative.
#2, 1/0, 2/0, 4/0
Cable Available
Optional Ground
Clamp Styles
“C” Type
Aluminum
Flat Face
Duck Bill
Th Ferrule
Duck Bill
Plain
RELIABLE EQUIPMENT & SERVICE CO., INC.
92 Steamwhistle Drive • Ivyland, PA 18974
Phone: 800-966-3530 • Fax: 215-357-9193
Visit us on the web at www.Reliable-Equip.com
Bronze
Flat Face
92 Steamwhistle Drive • Ivyland, PA 18974 • Phone: 800-966-3530 • Fax: 215-357-9193
GROUNDING CLAMPS AVAILABLE FROM RELIABLE EQUIPMENT
R-GC-1001
R-DB-1004
Style: Al., Curved, Serrated
Capacity: .16-2” # 6-3000 KCM ACSR
Current: 400 RMS Amps / 60 Hz
ASTM: Class B / Grade 5
Compare to: (Closest Match)
Salisbury # 20882
Chance # C600-2256
Hastings # 10375
Style: Al., Smooth
Capacity: .16-1.1” # 6-795 KCM ACSR
Current: 400 RMS Amps / 60 Hz
ASTM: Class A / Grade 5
Compare to: (Closest Match)
Salisbury # 24404
Chance # G3622-1
Hastings # 10478
R-GC-1002
R-DB-1005
Style: Al., Flat, Serrated
Capacity: .16-1.5” # 6-1431 KCMACSR
Current: 400 RMS Amps / 60 Hz
ASTM: Class B / Grade 5
Compare to: (Closest Match)
Style: Al., Smooth
Capacity: .16-1.1” # 6-795 KCM ACSR
Current: 400 RMS Amps / 60 Hz
ASTM: Class A / Grade 5
Compare to: (Closest Match)
Salisbury #21030
Chance # C600-1734
Hastings # 10476
“C” TYPE (THREADED)
“C” TYPE (THREADED)
Salisbury # 1895
Chance # T600-2708
Hastings # 21575
R-FC-1007
FLAT (THREADED)
Style: Al., Flat, Serrated
Capacity: .06-1.5” Flat or Square
Current: 400 RMS Amps / 60 Hz
ASTM: Class B / Grade 5
Compare to: (Closest Match)
Salisbury # 4345
R-FC-1006
FLAT (THREADED)
Style: Bronze, Flat, Serrated
Capacity: .06-1.5” Flat or Square
Current: 300 RMS Amps / 60 Hz
ASTM: Class B / Grade 3
Compare to: (Closest Match)
Salisbury # 1814
Chance # C600-2231
Hastings # 21608
DUCK BILL (P/T)
DUCK BILL (THREADED)
R-DB-1003
DUCK BILL (THREADED)
Style: Al., Serrated
Capacity: .16-1.65” # 6-1590 MCMACSR
Current: 400 RMS Amps / 60 Hz
ASTM: Class B / Grade 5
Compare to: (Closest Match)
Salisbury # 1853
Chance # C600-0197
Hastings # 10477
R-GR-PS
GROUND PARKING STUD
Style: Bronze
Compare to: (Closest Match)
Salisbury # 21754
Chance # G3627
Hastings # 13210
Consult your Inside Sales Representative forAvailability and Custom Assembly
92 Steamwhistle Drive • Ivyland, PA 18974 • Phone: 800-966-3530 • Fax: 215-357-9193
PLAIN (P/T) GROUNDING FERRULES #2 - 4/0
R-#2PF
Salisbury
Chance
Hastings
#2
R-1/0PF
24420
C600-2610
P30244
1/0
24421
C600-2611
P30245
R-2/0PF
2/0
24422
C600-2612
P30246
R-4/0PF
4/0
24423
C600-2613
P30247
THREADED GROUNDING FERRULES #2 - 4/0
R-#2TF
Salisbury
Chance
Hastings
R-1/0TF
#2
2022
C600-2602
12998
1/0
R-2/0TF
2023
C600-2603
12999
2/0
R-4/0TF
2024
C600-2604
13000
4/0
2025
C600-2605
13001
Consult your Inside Sales Representative forAvailability and Custom Assembly
REL-GSB
Pole Mounted
Ground Support Bar
Weight: 11 lbs.
REL-GSB
Pole Mounted Ground Support Bar
92 Steamwhistle Drive • Ivyland, PA 18974
Phone: 800-966-3530 • Fax: 215-357-9193
Visit us on the web at www.Reliable-Equip.com
If you have any questions regarding the information
found in this document please contact RELIABLE EQUIPMENT
at the address, phone or fax numbers shown below.
92 Steamwhistle Drive Ivyland, PA 18974
Phone: 800-966-3530 Fax: 215-357-9193
Visit us on the web at www.Reliable-Equip.com
20