Outside Plant Testing
T-BERD 209OSP

FEATURES
Introduction
T
he TTC® T-BERD® 209OSP meets the exclusive testing requirements of the outside plant technician.
Combining T1/ISDN/DDS/HDSL BERT, TDR, and DVOM, the T-BERD 209OSP is a complete tool for
qualifying and troubleshooting digital loops. By adding optional FT1 support, pre-programmed intelligent
equipment commands, and HDSL loop qualification, you have the most flexible, all-in-one solution for outside
plant testing.
• Full Span Transmitter and Receiver
Identify marginal troubles with standard T1 stress patterns at various output levels. Easily access signal and
error information. Service-effecting results are automatically displayed in SUMMARY RESULTS category.
• Cable Qualification
Identify cable impairments such as opens, shorts, bridged taps, load coils, splits, crimps, partial opens, grounds,
and resistive shorts. Distance to fault is displayed in feet.
• Automated Testing
Qualify T1 spans at the push of a button with AUTOTEST, automated MULTIPAT™ and BRIDGTAP™ stress
patterns, and automatic receiver configuration.
• Repeater Adapter
Cable-in once. Complete test access to repeatered
spans without the use of several cumbersome
cables.
• Graphical Display
Control test access with the push of a button. View
graphical TDR response to verify cable
impairments.
• Flash Memory
Complete field software upgrade in minutes.
• Lead Acid Battery
Five hours of testing time with lead acid
dependability.
• Rugged Enclosure
The rugged, NEMA-4X-compliant design keeps
the harsh elements out and the unit working, no
matter what the testing conditions.
The T-BERD 209 OSP
is the ideal outside
plant test set.
Options
209OSP-1
DC Measurements Option
209OSP-2
TDR Measurements Option
Ohms Measurements
Quickly identify physical impairments, such as opens,
shorts, grounds, and one-side faults with automated
resistance measurements between tip, ring, and ground.
Easy TDR Set Up
Simply select the cable type and approximate cable
length to configure the TDR for use. Avoid the cumbersome process of determining complex constants, such
as pulse width and pulse height.
Amps Measurements
Immediately detect one-side faults, such as opens and
grounds, with an automated current measurement between tip and ring.
Volts Measurements
Quickly isolate bad repeaters and span powering problems with automated voltage measurements.
DISTRIBUTION
FRAME
REPEATER
Graphical Display
Immediately view the TDR trace on the front panel
graphical display. Utilize the built-in zoom feature to
identify faults such as splits, load coils, high-resistance
opens, and bad splices.
Fault Identification
Automatically identify and locate opens, shorts, and
bridged taps. Distance to fault is displayed in feet.
REPEATER
ADAPTER
REPEATER
NIU
Quickly isolate T1 span
troubles by testing in
any direction.
T-BERD 209OSP
T1 REPEATER PORT
REPEATER
Accurately identify and
locate line faults using
the DC and TDR
Measurement Options.
REPEATER
ADAPTER
REPEATER
T-BERD 209OSP
T1 REPEATER PORT
Options
The T-BERD 209OSP is
lightweight, portable,
and designed for the
way you test.
209OSP-3
Channel Monitor Option
209OSP-5
Enhanced ESF Option
Simultaneously monitor ABCD signaling bits of all 24
timeslots. Listen to voice quality and view the data bits of
an individual DS0.
Decode ESF one-second broadcast PRMs to verify
remote, in-service circuit performance.
209OSP-4
Advanced Stress
Patterns Option
Stress repeater ALBO circuits with 55 OCTET, T1 DALY,
and other long user patterns as recommended by the
ANSI T1.403 standard.
Emulate ANSI T1.403-compatible CSU equipment to verify
proper operation during circuit installation and fault
isolation.
Query performance monitoring NIU equipment and
retrieve in-service performance data to verify remote
circuit operation. Supports WestellTM equipment.
Options
209OSP-6
Smart Loopback/Command
Codes Option
Send and receive commands for maintenance switch
operation to minimize circuit downtime and query
performance data. Supports TeltrendTM and Westell
equipment.
Utilize intelligent repeater technology to qualify
and isolate troubles on outside plant spans. Supports
Teltrend, Westell, WescomTM, XELTM, and TxPortTM
equipment.
209OSP-7
Fractional T1 Option
Utilize intelligent
repeater technology
to sectionalize span
problems.
Perform bit error rate tests on selected channels to verify
transmission quality on contiguous and non-contiguous
FT1 bandwidth.
Verify VF circuit performance with 404, 1004, 2804, and
2713 Hz tones at various output levels.
DSX-1
Use pre-programmed
loop codes to
sectionalize span
problems with the
Smart Loopback/
Command Codes
options.
INTELLIGENT
OFFICE
REPEATER
T-BERD 209OSP
Rx
Tx
DISTRIBUTION
FRAME
INTELLEGENT
LINE REPEATER
INTELLEGENT
LINE REPEATER
NIU
Perform loss measurements at 28kHz, 40kHz, 48kHz,
82kHz, 163kHz, 196kHz, and 392kHz to assure proper
signal level at equipment inputs for HDSL, Basic Rate
ISDN, and DDS circuits.
Options
209OSP-8
HDSL/ISDN/DDS Measurement
Option
Ensure that the local loop does not exceed the CSA
requirements for maximum length, including bridged
tap length, when provisioning HDSL, Basic Rate ISDN,
and DDS circuits.
Quickly sectionalize transmission troubles with preprogrammed HTU-C, HTU-R, and doubler loop codes.
Supports Pair Gain™, Tellabs™, Adtran™, Westell,
and ADC™ equipment.
CO
CPE
Measure total length of
the loop, including
bridged taps, to verify
that it meets CSA
standards.
T-BERD 209OSP
Tx/TDR
CO
CPE
T-BERD 209OSP
T-BERD 209OSP
Rx
Rx
Tx
Tx
Measure signal loss
to qualify loop
integrity prior to
circuit turn-up.
ISDN/DDS Option
The ISDN/DDS Analyzer
Option will power-up
and BERT the
entire span.
209OSP-9
ISDN/DDS Analyzer Option
Now you can qualify ISDN and DDS pairs during installation – avoiding kickbacks and missed dates. With the new
ISDN/DDS testing option, your T-BERD 209OSP will
power-up and BERT the entire span. This will enable you
to detect troublesome bridged taps, load coils, wiring
problems, and bad repeaters prior to the customer
due date.
Full Span DDS Transmitter and Receiver
Perform BER measurements for 2.4, 4.8, 9.6, 56.0, and
64.0 kb/s service on both primary and secondary
channels. Identify marginal troubles with all standard
DDS patterns at various output levels.
Power-up and qualify
ISDN or DDS pairs prior
to installing central
office equipment.
Full Span ISDN U Interface
Perform BER measurements for Basic Rate ISDN service.
Qualify the local loop for 2B+D service – locating
troublesome load coils and bridged taps.
Span Power
Power-up and test repeatered DDS and ISDN loops prior
to the installation of the central office equipment. Identify bad repeaters and marginal circuit performance.
Pre-Programmed Loop Codes
Isolate troubles on DDS and Basic Rate ISDN circuits with
pre-programmed repeater, CSU, and NT1 loop codes.
CPE Emulation
Sectionalize between local loop and CPE troubles with
automatic response to CSU and NT1 loop codes.
T-BERD 209OSP
T-BERD 209OSP
ISDN/DDS
ANALYZER
Tx/Rx
ISDN/DDS
ANALYZER
Tx/Rx
OCU-DP/BRITE
REPEATER
CSU/NT1
DLC/DS0 Option
Verify DLC/DS0 circuits
in-service with the DLC/
DS0 Analyzer Option.
209OSP-96
DLC/DS0 Analyzer Option
SLC-96 Datalink Emulation
Verify central office switch and terminal response to
alarms, far-end loopbacks, and line protection switches.
Execute test pair maintenance requests during system
installation and in-service maintenance.
Full Duplex Channel Monitor
Decode signaling bits in both directions on all channels
simultaneously. Listen to either or both directions of a VF
circuit by dropping the channel(s) to the internal speaker
or an external TIMS.
Two-Wire VF Input/Output
Connect butt-set for DTMF digit transmit, call placement,
and talk path for subscriber maintenance and PBX
applications.
Channel Insert
Insert either internal test tones or voice and digits from
an external butt-set, and control signaling bits without
disrupting the remaining active channels.
SLC-96 Mode 2 Configuration
Timeslot Assignment Results
Determine channel and timeslot assignments for
systems configured for SLC-96 Mode 2 concentrated
applications.
SLC®-96 Datalink Monitor
Capture major and minor shelf alarms, far-end
loopback, line protection switches, and maintenance
events in both directions for non-intrusive, in-service
verification.
REMOTE
TERMINAL
DSX-1
D SHELF
DIGITAL
SWITCH
C SHELF
B SHELF
A SHELF
T-BERD 209OSP
Rx
Tx
DLC ANALYZER
Ensure remote
terminal operation,
verify voice-grade
service, and validate
signaling transmissions during system
qualifications.
Accessories
Save time and money
with T-BERD Repeater
Power Supply and Span
Power Multiplexer.
T-BERD Repeater Power Supply
Power-up a T1 circuit from the distribution frame, and
use the T-BERD 209OSP to test and qualify circuits prior
to the installation and connection of the central office
repeater.
T-BERD 209OSP Span Power Multiplexer
Improve your process and testing efficiency. The Span
Power Multiplexer allows you to switch automatically
between T1s in the field, and is compliant with UL, FCC,
and CSA safety restrictions.
• Select between 60 mA, 100 mA, and 140 mA
current selections.
• Remotely switch power between up to six
T1 spans.
• Displays span voltage and current for comparison with circuit design.
• Use with standard and intelligent line repeaters.
• Complies with UL and FCC safety restrictions.
• Provides a regenerative signal loopback for
single-technician applications.
T-BERD REPEATER
POWER SUPPLY
Power up and qualify
up to six spans for
faster, more accurate
T1 turn-up.
T-BERD REPEATER
POWER SUPPLY
MULTIPLEXER
T-BERD 209OSP
LIGHTNING
PROTECTION BLOCK
REPEATERS
TTC United States
California, Colorado, Georgia, Illinois,
Maryland, New Jersey, Texas, Washington
TTC Subsidiaries
Australia, 61-3-9563.4800; Canada, 905-507-4117;
France, 33-1-30.48.83.90; Germany, 49-6172.5911-00;
Hong Kong, 852-2892-0990; United Kingdom, 44-1189-759696
Behind Successful Networks
You’ll Find TTC
20400 Observation Drive, Germantown, Maryland 20876
Tel. (800) 638-2049 • (301) 353-1550 (MD) • FAX (301) 353-0234
www.ttc.com
TBOSP - 9/97