JBOD1024 - LILIN Technical Support

JBOD1024
24 BAY HOT SWAP
RACK MOUNT SATA/SAS JBOD
The JBOD1024 JBOD (just a bunch of disks) storage enclosure is designed to scale your LILIN 1108 / 1072 server storage expansion capacity. In a 4U
form factor, it offers 24-hour hot-swappable 3.5" SAS/SATA hard drive bays, without compromising superior cooling capabilities. This JOBD1024 model
offers two expanders for high availability. Just install hard drives and use an external SAS cable and connect to a host bus adapter (HBA) on the head
node server. The storage capacity can be expanded instantly and reduce the initial investment.
 4U Storage JBOD Chassis with capacity 24 x 3.5" hot-swappable HDDs bays
 Single Expander Backplane Boards support SAS3/2 HDDs with 12Gb/s throughput
 2 x Mini-SAS HD ports for Internal / External Cascading Expander Combination
for high performance, high availability or high redundancy requirements
 920W (1+1) 94% efficient Platinum level power supplies
 5 hot-plug redundant cooling fans
 Ideal for Cloud backup, data Replication or High density Archive Storage Applications
Dimension (W x D x H): 17.2” x 26” x 7”
Technical Specifications
24 BAY HOT SWAP RACK MOUNT SATA/SAS JBOD
Front Panel
Power On/Off button
Buttons
Model#
System Reset Button
Unit Identification (UID) button
JBOD1024
LEDs
1 Network Activity LEDs
Form Factor
Power Supply with Power Distributor
4U chassis
920W high-efficiency (94%+) AC-DC Redundant power supplies with PMBus and I2C
Processor Support
AC Input
100-240 V, 50-60 Hz, 11-4.5 Amp
N/A
DC Output
4 Amp @ +5V standby
75 Amp @ +12V
Certification (Platinum
Dimensions
Height
7" (178mm)
Width
17.2" (437mm)
Depth
26" (660mm)
Packaging
27'' (W) x 14.8''(H) 37.3'' (L)
Gross Weight
80 lb (36.29 kg)
Available Colors
black
Certified)
Regulatory (Power Supply)
USA - UL listed, FCC
Canada - CUL listed
Power Supply Safety / EMC
Germany - TUV Certified
Europe/CE Mark
EN 60950/IEC 60950-Compliant
Drive Bays
JBOD Chassis
Up to 24 x 3.5" hot-swap HDD bays for JBOD solution
Backplane
SAS 12G single expander backplane, with LSI SAS3 expander, support 24x 3.5"
System Cooling
Fans
SATA3/SAS2/SAS3 drives, with 4x mini-SAS HD connectors
3x 8cm hot-swap redundant PWM cooling fans
2x 8cm hot-swap exhaust fans & air shroud
Operating Environment (System)
Operating Temperature Range
5°C〜35°C (41°F〜95°F)
Non-Operating Temperature
-40°C〜60°C (-40°F〜140°F)
Range
Operating Relative Humidity
8%〜90% (non-condensing)
Range
Non-Operating Relative
5%〜95% (non-condensing)
Humidity Range
Copyright © Merit LILIN 2016 | All rights reserved | Product specifications and availability are subject to change without notice