INSTALLATION SHEET
270 Transient Suppression Module
Description
The Model 270 Transient Suppression Module provides surge suppression from the
Ethernet network for the protection of DMP Panels. The 270 Transient Suppression
Module may be installed with XR150/XR350/XR550 Series or XR150INT/XR550INT
Series international control panels.
Installation
The 270 Transient Suppression Module is designed to easily mount inside the panel
enclosure using the standard 3-hole mounting configuration.
J2
J1
Figure 1: Front View 270
Transient Suppression Module
1. Mount the plastic standoffs to the enclosure using the three included Phillips head screws.
2. Insert the screws from the outside of the enclosure through the holes and into the plastic standoff that mounts
on the inside of the enclosure.
3. After tightening and securing the standoffs onto the enclosure, snap the 270 onto the standoffs.
4. Install the included DMP 357-2 cable between the 270 Ethernet connector (J1) and the panel Ethernet
connector (J1).
5. Using either side of the two-position terminal strip on the 270, connect an 18 gauge or larger ground wire to
terminal 4 on the panel.
6. Connect the Local Area Network (LAN) to the 270 Switch/Router connector (J2).
Ground Yourself Before Handling the Panel! Touch any grounded metal, such as the enclosure, before
touching the panel to discharge static.
Remove All Power From the Panel! Remove all AC and Battery power from the panel before installing or
connecting any modules, cards, or wires to the panel.
Note: For UL listed installations, the Model 270 must be used if the network switch is not installed in the same room
as the panel.
J3
J2
J1
357-2 Cable
K
18 Ga.
Ground wire
Figure 2: Model 270 to XR550
6 oz
.16 Kg
2.75" W x 1.6" H
Certifications
ANSI/UL 985
Household Fire Warning
ANSI/UL 1023
Household Burglar
ANSI/UL 1076
Proprietary Burglar
ANSI/UL 1610
Central Station Burglary
ANSI/UL 1635
Digital Burglar
ANSI/UL 864Fire Protective Signaling
9th Edition
ULC S545
Household Fire
ULC Subject-C1023 Household Burglar
ULC/ORD-C1076 Proprietary Burglar
ULC S304 Central Station Burglar
ULC-S559-04Equipment for Fire Signal
Receiving Centers and
Systems
International Certifications
EN 50133-1:1997
Access Control Systems
EN 50130-4EMC Product Family Standard:
Immunity Requirements for
Components of Fire, Intruder and
Social Alarm Systems
EN 50130-5
Environmental Standards
EN 61000-3-2Limits - Limits for Harmonic
Current Emissions (Equip.Input
Current up to and Including 16 A
per Phase) Includes A1 & A2 July 1,
2009
EN 61000-3-3Limitation of Voltage Fluctuations
& Flicker in Low-Voltage Supply
Systems for Equip. with Rated
Current Less Than or Equal to
16 A per Phase & Not Subject to
Conditional Connection
EN 61000-6-4Generic Standards - Emission
Standard for Industrial
Environments
Security Grade:
3
Environmental Class: II
Intertek (ETL)
EN 50131-1:2006+A1Intrusion and hold-up
systems
EN 50131-3:2009Control and Indicating
Equipment
EN 50131-6:2008
Power Supplies
800-641-4282
INTRUSION • FIRE • ACCESS • NETWORKS
www.dmp.com
2 5 0 0 N o r t h Pa r t n e r s h i p B o u l e v a r d
Designed, Engineered
and Assembled in U.S.A.
Springfield, Missouri 65803-8877
16205
Weight
Dimension
LT-1316 1.01 © 2016 Digital Monitoring Products, Inc.