InterReach Fusion Installation Quick Reference

InterReach Fusion Installation Quick Start Guide
Important Installation Information and Procedures—
Read before Installing and Powering on Fusion Equipment
This document is not intended to replace the InterReach Fusion Installation,
Operation, and Reference Manual (FSNP-302), which can be accessed at
http://www.commscope.com/collateral/interreach_fusion
DOCUMENTATION NEEDED
INSTALL THE FUSION SYSTEM
•
SystemDesignDocumentforthisinstallationsite
CAUTION: Fusion components are intended for indoor
•
Thefollowinguserdocuments,whichprovide
informationonFusionandFusionWidebandsystems:
–
AdminBrowserUserManual(FSNP-301-01)
–
FusionInstallation,Operation,andReference
Manual(FSNP-302-01)
installation only.
CAUTION: Provide sufficient air flow and cooling to the
equipment to prevent heat build-up in excess of
the maximum ambient air temperature
specification. Clearance for air circulation is as
follows:
Fusion Main and Expansion Hubs:
Front and Rear: 76 millimeters (3 inches)
Sides: 51 millimeters (2 inches)
Top and Bottom: zero clearance
EQUIPMENT NEEDED
•
FusionHubsandRAU(s)
•
LaptopPCforAdminBrowser
•
TCP/IPCrossovercable(PN4069-ADB),whichships
withtheFusion
•
Plenum-ratedfiber,CATVcables,andconnectorsfor
conformitytobuildingcodesandstandardsare
recommended
•
UseonlySC/APCfiberconnectorsfortheentirefiber
run.Anyotherconnectortypewillresultinanonfunctioningsystemandmaydamagetheequipment.
SC/APCpigtailsareavailablefromCommScope.
NOTE:
The CATV cable’s F-connectors must be
installed correctly to the shield at both ends.
NOTE:
The Fusion One-Port Main Hub (FSN-1-MH-1P
and FSN-W1-MH-1P) configuration is a costreduced version and supports only one fiber
port and one Expansion Hub; it is shown below.
RAU: Requires 76 millimeters (3 inches) on all
sides except the mounting hole faceplate,
which must be flush against the RAU’s surface.
CAUTION: Only carriers and approved installers are
allowed to connect to the RF source. Serious
damage to the equipment can occur if it is overdriven.
I.
DO THE FOLLOWING BEFORE CONNECTING THE HUBS
1.
Verifythatthesingle-modeormulti-modefiberis
Corning,orequivalentwithSC/APCconnectors.
2
Confirmthatthetotalopticallossofeachfibercable
(includingpatchpanels)doesnotexceedthe3dB
opticalbudget,measuredat1310nm.
3
VerifythattheCATVcableisCommscopecable:
2065V(RG-59),2279V(RG-6),or2293K(RG-11),or
equivalent.Allmustbeterminatedwithquality
connectors,suchasCanarecenter-pin,maleF
connectorsorequivalent.RefertoAppendixAinthe
FusionInstallation,Operation,andReferenceManual
(FSNP-302-01)forothercableoptions.
4
VerifythatCATVcablestesttoTIA-570-B.TheRAU
willbedamagediftheCATVconnectorisnot
installedcorrectly.
5
VerifythatRFinputpowerdoesnotexceed1Watt.
6
VerifythattheHubisgroundedsafelyusingthethird
wiregroundontheACplugortheframegroundonthe
DCHubs.RefertotheInstallationManualfor
additionalinformation.
7
Verifythattheportsareclean.
8
Leavethedustcapsonthefiberportsuntilyouare
readytoconnectthefiberopticcables.
PC/Laptop is running Internet Explorer
and is connected to the Main Hub’s
front panel RJ-45 connector.
InterReach Fusion
Connecvity
PORT 1 PORT 2 PORT 3 PORT 4
RS-232
RJ-45
Main Hub
Single-Mode or Mul-Mode
Fiber Opc cable
Fiber
Expansion Hub
Expansion Hub
Expansion Hub
CATV (RG-59, 6,
or 11)
RAU
CATV
RAU
Up to 8 RAUs per Expansion Hub
Up to 4
Expansion Hubs
Expansion Hub per Main Hub
CATV
RAU
NOTE:
FSNP-303-01
© October 2016 CommScope, Inc.
Do not use 75 ohm terminators on any F-connector port. Doing so causes the system to generate false alarms.
InterReach Fusion Installation Quick Reference Guide
Page 1 of 5
Notethattheremaybetimeswhenanidentified
locationwillnotlogisticallywork.PlacetheRAUas
neartotheindicatedlocationaspossible.
II. INSTALL THE FUSION MAIN HUB
1.
2
Usingthescrewsprovided,attachtheMainHubtoa
standard19”equipmentrack(orwall-mountwiththe
enclosedbrackets;refertotheInstallationManual).
ConnecttheMainHub’sACorDCpowersourceand
turniton.
AllLEDsblinkthroughthepowerupsequence.Ateach
portwhereaRAUisdetected(drawingcurrent),the
portLEDsturngreen.TheFusionSTATUSLEDis
orangeduringsystembootandshouldturngreenafter
about90secondsifitfindsnofaults.Thisstate
indicatesthebandsarenotprogrammedandprovides
feedbackonthestatusoftheRAUconnections.
3
2
IftheHubison,theRAULEDsshouldblinkfor2
seconds.Iftheydonot,refertotheFusionmanual.
V. INSTALL THE ANTENNAS
Use50-Ohmcoaxialcablewithminimalloss(forRF
performance)andmaximalflexibility(forinstallation
convenience).
TheLEDsblinkfor20secondsasavisualcheckthat
theyarefunctioning.
Installantennasaccordingtomanufacturer’sinstallation
instructions.Antennasareusuallyinstalledbelowthe
ceiling.
ConnecttheExpansionHub’sDownlinkfiberoptic
cabletotheMainHub’sDownlinkfiberportandthe
UplinkcabletotheUplinkport.
F. CONNECT THE ANTENNAS TO THE RAUS
1.
WhenyouconnectaradiatingantennatoaRAU,
torqueappliedshouldbe7±5%in-lbs.DONOTovertightentheconnector.
2
Usinga50-Ohmcoaxialcable,connecttheantennato
thefemaleN-connectorontheRAU.
III. INSTALL THE FUSION EXPANSION HUB
1.
AttachtheExpansionHubtoastandard19”equipment
rackoroptionalwallmountbracket.
2
ConnecttheExpansionHub’spowersourceandturnit
on.
3
ConnectthefibercablestotheDownlinkandUplink
portsontheExpansionHub.Makeanoteofwhich
cableisusedineachport.
AfterthepoweronLEDblinks,theUplinkLEDshould
turngreenandstaygreen.Oncethedownlinkfiberis
connected,andtheMainHubispoweredon,the
DownlinkLEDshouldturngreen.
4
ConnectthetestedCATVcabletotheF-connector
femaleportontheRAU.
EnsurethattheCATVcableiswiredcorrectlyandthat
thecabledoesnotexceedmaximumlengthpercable
type.
5
TesttheCATVcablesperTIA-570-Bbeforeyou
connectthemtotheHub.
6
ConnecttheCATVcablestoanyavailableFconnector
port.MakeanoteofwhichRAUcableyouare
connectingtowhichport.
NOTE:
Do not use 75 ohm terminators on any F-connector port. Doing so causes the system to generate false alarms.
IV. INSTALL THE RAUS
VI. CONFIGURE YOUR PC TO COMMUNICATE WITH THE MAIN
HUB
BeforeyouaccessAdminBrowserforthefirsttime,youmust
configureyourPCsoitcancommunicatewiththeFusion
MainHub.
ThefollowingstepstellyouhowtologintoAdminBrowser
usingadirect-connectcableinWindows7.Theactualsteps
thatyoufollowmaydiffer,dependentontheWindows
operatingsysteminstalledonyourPC.
1.
Connectthecross-overEthernetcabletothePC/laptop
andthentotheRJ-45100-BASE-TportontheMain
Hub’sfrontpanel.
2
OnyourPC,clickStart > Control Panel.
3
IntheAll Control Panel Items window,clickNetwork
and Sharing Center.
4
IntheNetwork and Sharing Centerwindow,click
Change adapter settings.
5
Double-clickontheactiveLocal Area Connection.
6
IntheLocal Area Connection
window,clickProperties.
CAUTION: Always mount a RAU with its mounting hole
faceplate against the mounting surface.
CAUTION: Only install RAUs indoors or in an approved
CommScope enclosure.
CAUTION: 54VDC is present on the CATV cable when the
cable is connected to a powered Expansion
Hub.
1.
SecurelymountallRAUsinthelocationsidentifiedby
theSystemDesignfloorplandocuments.
FSNP-303-01
© October 2016 CommScope, Inc.
InterReach Fusion Installation Quick Reference Guide
Page 2 of 5
7
IntheLocal Area Connection
Propertieswindow,select
Internet Protocol Version 4
(TCP/IP4),andthenclick
Properties.
c
d
8
8
MakenoteofthecurrentIP address,Subnet mask,and
Default gateway,iftheyareconfigured.Youwillneedto
re-enterthemafteryouhaveconfiguredtheFusion
MainHub.
9
SelectUse the following IP address.
IntheStart DateandEnd Datepanels,usethe
MonthandDaymenustosetthedatethatdaylights
savingstimestartsandends.UsetheTimetext
boxestoenterthestartandendtimein24-hour
clockformat(hh:mm).
ClickSetup Daylight Savings Time.
ClickReboot.
TheReboot Systempageopenswithsystemreboot
messages,whichincludesanestimateofhowlongit
willtakeforthereboottocomplete.Ignorethe
followingmessageastheinitialsetupstepsarenot
achievedviaananalogmodem:If you are connected to
the system through a modem, please disconnect it now.
a WaitfortheEstimated time to completion (mm:ss)
messagetoshow00:00.
b ClickReturn to Home page.
c AdminBrowserlogsyououtofyourcurrent
session.
d LogbackintoAdminBrowser.
10 EnterthefollowingIP address:192.168.0.101
11 EnterthefollowingSubnet mask:255.255.255.0
12 EnterthefollowingDefault gateway:192.168.0.1
ClickSystem Configuration > Install System.
13 ClickOKtwice.
9
14 Youmaybeaskedifyouwanttorebootyourcomputer.
Ifso,clickYes.
10 IntheGeneralpanel,settheparameterslistedafterthe
graphic.
VII. PROVISION THE MAIN HUB
1.
Startyourwebbrowser.
2
InthewebbrowserURLbox,typeintheURLaddress
oftheFusionsystemsuppliedbyyoursystem
administrator.
3
YoumayencountertheInternetExplorersecurity
popupshownbelowbeforeyoucanaccessthe
AdminBrowser.Ifawebsitesecuritywindowopens,
clickContinue to this website (not recommended) to
continue.
4
IntheAdminBrowser LoginpageUsernamebox,type
thedefaultusername:operatorandinthePassword
box,typethedefaultpassword:password.
5
ClickLog On.TheAdminBrowser Homepageopens.
6
ClickSystem Configuration > Set Date/Timetoopenthe
Set Date/Timepageandthendothefollowing,as
necessary.
a UsetheDateboxtoenteranewdateinMM/DD/
YYYYformat.
b UsetheTimeboxtoenteranewtimein24-hour
clockformat(hh:mm:ss)
c ClickSet Date/Time.
7
IfyouneedtoconfigurethesystemforDaylight
SavingsTime,dothefollowing;otherwise,gotoStep8
toreboottheMainHub.
a ClickSystem Configuration > Setup Daylight Savings
TimetoopentheSetup Daylight Savings Timepage.
b SelecttheEnablecheckbox.
FSNP-303-01
© October 2016 CommScope, Inc.
a
b
UsetheLabeltextboxtoenteralabelbywhichyou
canidentifythisFusionsystemintheSystemTree
andinsystemmessages.TheLabelcanbeupto32
characterslong,andcannotcontainaspaceorthe
followingspecialkeyboardfollowingspecial
keyboardcharacters:#,$,&,},!.ThedefaultLabel
isFusion.
Recommended—SelecttheSystem Test on Power
UpcheckboxtorunSystemTesteachtimeyou
poweruptheMainHub.(TodisableSystem Test on
Power Up,clickonthecheckmarktoremoveit.)
CAUTION: System Test suspends RF for 35 seconds at the
start of the test. Normal service for the
duration of the test is also suspended—calls are
dropped, and no new calls can be established
during the test. System Test duration depends
on the configuration (number of RAUs) and
requires one or two minutes to complete.
NOTE:
The System Date and Time (Approximate) panel
provides a snapshot of the current system date
and time, which are maintained by a batterybacked Real Time Clock.
InterReach Fusion Installation Quick Reference Guide
Page 3 of 5
11 UsetheSchedule System Testpaneltosetupan
automaticexecutionofSystemTest.
a
b
c
d
SelecttheEnablecheckboxtoenableSystemTest.
(TodisableSystemTest,clickonthecheckmarkto
removeit.)
UsetheDateboxtoentertheSystemTestdatein
MM/DD/YYYYformat.
UsetheTimeboxtoentertheSystemTesttimein
24-hourclockformat(hh:mm:ss).
TosetuptheautomaticrecurrenceofSystemTest,
dooneofthefollowing:
• TohaveSystemTestrecuronaninterval
countedbydays,selecttheRecurrence Day(s)
(1-30)radiobutton,andtheninthecorrespondingbox,enterhowmanydaysshould
passbetweeneachoccurrenceofthisSystem
Test.
• TohaveSystemTestrecuronaninterval
countedbyweeks,selecttheRecurrence
Week(s) (1-4)radiobutton,andtheninthecorrespondingbox,enterhowmanyweeks
shouldpassbetweeneachoccurrenceofthis
SystemTest.
•
whichbandsthesystemshouldignoreany
alarms.
iii UsetheUplink GainandDownlink Gain
menustospecifythegainforeachband,in
onedBincrements.
iv UsetheUplink Automatic Level Control
menustosetALCtoSingleorMultiplefor
eachbandinthesystem.Inatypical
wirelessdeployment,youselectMultiple
(default).
v GotoStep6tosettheInputandOutput
Alarms.
TosettheBandsinaTDDSystem,inthe
Bandspanel,dothefollowing:
i
UsetheProtocol radiobuttonstoselectthe
Protocolmode.
• MIMO—setstheconfigurationtoMultipleIn-MultipleOut(default),in
whichthefrequenciesarethesame
anduptothreecontiguous20MHz
MIMOradioscanbesupported.
•
AftercompletionofSystemTest,thescheduledSystem
Testtimeisupdatedtothenexttesttime,andanevent
logentryismade.
SISO—setsthebandprotocoltoSingle
In-SingleOut.Thesystemcansupport
sixSISOradios,threeperbandacross
any66MHzwithintheband.
12 SettheSystemBands—makesureyoufollowthe
stepsthatareapplicabletotheFusionsystemthat
youareconfiguring.
CAUTION: CommScope equipment is designed to operate
in the licensed frequency bands of mobile
operators. In the USA, the EU, and most
countries this equipment may only be used by
the licensee, authorized agents, or those with
written authorization to do so. Similarly,
unauthorized use is illegal, and subjects the
owner to the corresponding legal sanctions of
the national jurisdiction involved. Ownership of
CommScope equipment carries no automatic
right of use.
•
TosettheBandsinaNon-TDDSystem,in
theBandspanel,dothefollowing:
ii
iii
iv
v
i
ii
UsetheBandspull-downtoselectthe
band.
Ifallbandsarenotconfigured,usethe
Shutdowncheckboxestoidentifyfrom
FSNP-303-01
© October 2016 CommScope, Inc.
vi
UsetheCenter Frequency (MHz) menuto
setthefrequencyofWiMAXradiosbeing
usedforBand1andBand2.
UsetheBandwidth (MHz) menutosetthe
bandwidthto66 MHz (default)or30 MHz.
Ifanybandisnotconfigured,usethe
Shutdowncheckboxestoidentifyfrom
whichbandsthesystemshouldignoreany
alarms.
UsetheUplink GainandDownlink Gain
menustospecifythegainforeachband,in
onedBincrements.
UsetheUplink Automatic Level Control
menustosetALCtoSingleorMultiplefor
eachbandinthesystem.Inatypical
wirelessdeployment,youselectMultiple
(default).
InterReach Fusion Installation Quick Reference Guide
Page 4 of 5
vii GotoStep13tosettheInputandOutput
Alarms.
13 SettheInputAlarms andOutputAlarms.
CAUTION: Do not enable the input alarms unless they will
be used to monitor an external contact.
a
b
IntheInput Alarmspanel,dothefollowingforeach
ofthethreeAlarm Senserows(1 - 3),as
appropriateforyoursystem.(Alarm Sensealarms
arecommonlyreferredtoas“contactalarms.”)
i
SelecttheEnablecheckboxtoenableAlarm
Sense(1 - 3).(TodisableAlarm Sense,clickon
thecheckmarktoremoveit.)
ii UsetheNormal Statemenutosettheinput
alarmtoClosed(default)orOpened.
iii UsetheLabelboxtoassignanametoeach
alarmsense.TheLabelcanbeupto32
characterslong,andcannotcontainaspaceor
thefollowingspecialkeyboardfollowing
specialkeyboardcharacters:#,$,&,},!
IfBTSmonitoringoftheDASisdesired,then
performthefollowingstepsintheOutput Alarms
panel:
i
SelecttheFault Source Enablecheckboxto
enabletheFault Sourceoutputalarm.(To
disableFaultSource,clickonthecheckmarkto
removeit.)
ii UsetheNormal StatemenutosettheFault
SourceoutputalarmtoClosed(default)or
Opened.
iii SelecttheWarning Source Enable checkboxto
enabletheWarningSourceoutputalarm.(To
disableWarningSource,clickonthecheck
marktoremoveit.)
iv UsetheNormalStatemenutosettheWarning
SourceoutputalarmtoClosed(default)or
Opened.
15 ToseetheresultsofInstall System,clickSystem
Configuration,andreadtheinformationinthe
Messageslist.NotethatifyoulabeledtheMainHub,
thatlabelnowappearsintheSystemTree.
16 ChecktheiconsintheSystemTree;theyshouldbe:
Indicates that the band is correctly set on the Main
Hub.
Indicates that the band is correctly set on the
Expansion Hub.
Indicates that communications are OK.
Ifthereareproblems,theiconswillbedifferentanda
messageisdisplayedintheMessagespanel.
17 ConnecttheMainHubtotheRFsource(forexample,
BTSorBDA).
CAUTION: Do not exceed the maximum input RF power
(1 Watt-composite per band) to the Fusion Hub.
Exceeding the limit could cause permanent
damage to the Hub.
TheFusionsystemshouldnowbeoperational.
VIII. VERIFY THE INSTALLATION
1.
CheckLEDstatus:allPORTLEDsshouldbegreen.
2
Checkallfaults,warnings,andstatusmessages.
Eliminateallfaultsandwarnings.Checkallstatus
messagestoensurethatyouunderstandeachmessage
astohowitmayimpactservice.
3
Walkthesiteanduseamobilephonetotestthesignal
strength.
4
DothefollowinginAdminBrowser:
a UsetheGetServiceInformationfunctiontocollect
valuableinformationaboutthesystemintoa
singlefile.Youcanthenusethistextfileto
document,troubleshoot,andmaintainthesystem.
i
ClickSpecial Features > Get Service Information.
Awindowordialogthatcorrespondstothe
webbrowseryouareusingopensandasksif
youwanttoopenorsavethefile.
i
Followthepromptstosavethefiletoyour
laptoporPC.Thefilenamewillbeintheformat
of:
MainHubName_ServiceInfo_YYYYMMDDHHMMSS.rtf
b ClickSystem Information > Get Time-Tagged Log.;
reviewthelogtocheckforproblems,andthen
clickErase Log
5
ChangetheTCP/IPsettingsinyourlaptopbacktotheir
originalvalues.
14 ClickInstall System.
TheInstall Systempagedisplaysthefollowingmessage:
The system has been updated. A system test will begin in
a few seconds.
ThePerform System Testpagedisplaysthefollowing
message:Performing system test. Please wait.
• IfSystemTestdidnotfindanyproblems,thePerform System Testpagedisplaysthefollowingmessage:There are no faults, warnings, or statuses.If
youseethismessage,skiptoStep15.
• IfSystemTestfoundoneormoreproblems,the
PerformSystemTestpagedisplaysthefollowing
message:Getting faults, warnings, and statuses…
andthendisplaysaCurrent Faults, Warnings and
Statusestable.Ifnecessary,toresolveanyissues,
completethestep(s)intheRemedycolumnofthe
CurrentFaults,WarningsandStatusestable.
FSNP-303-01
© October 2016 CommScope, Inc.
InterReach Fusion Installation Quick Reference Guide
Page 5 of 5