KayakDD Installation Planning Guide

KayakDD
DIGITAL PRODUCTION SWITCHER
Installation Planning Guide
071832400
MAY 2004
Contacting Grass Valley
Region
Voice
Fax
Address
Web Site
North America
(800) 547-8949
Support: 530-478-4148
Sales: (530) 478-3347
Support: (530) 478-3181
www.thomsongrassvalley.com
Pacific Operations
+852-2585-6688
Support: 852-2585-6579
+852-2802-2996
Grass Valley
P.O. Box 599000
Nevada City, CA 959597900 USA
U.K., Asia, Middle East
+44 1753 218 777
+44 1753 218 757
France
+33 1 45 29 73 00
Germany, Europe
+49 6150 104 782
+49 6150 104 223
Copyright © Thomson Broadcast and Media Solutions All rights reserved.
Grass Valley Web Site
The www.thomsongrassvalley.com web site offers the following:
Online User Documentation — Current versions of product catalogs, brochures,
data sheets, ordering guides, planning guides, manuals, and release notes
in .pdf format can be downloaded.
FAQ Database — Solutions to problems and troubleshooting efforts can be
found by searching our Frequently Asked Questions (FAQ) database.
Software Downloads — Software updates, drivers, and patches can be down-
loaded.
2
KayakDD Installation Planning Guide
Contents
Installation Planning Guide
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Supported Control Protocols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
KayakDD-1 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
KayakDD-1 System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
KayakDD-1 Control Panel Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Panel Mounting Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Table Top. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Surface Mount Cut Out Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Fastening to Table Top . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
KayakDD-1 Video Processor Frame Installation . . . . . . . . . . . . . . . . . . . . . . . . . 11
Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Rack Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
KayakDD-1 Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Control Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Video Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
KayakDD-2 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Kayak DD-2 System Components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Kayak DD-2 Control Panel Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Panel Mounting Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Table Top. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Surface Mount Cut Out Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Fastening to Table Top . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Frame. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Rack Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
KDD-PSU Power Supply Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
KayakDD Installation Planning Guide
3
Contents
4
KayakDD Installation Planning Guide
Installation Planning Guide
Introduction
The Grass Valley KayakDD™ digital production switcher is an affordable,
compact, and flexible system that offers an array of high-end features for
everything from live studio and mobile production to small corporate
studios and editing applications. The KayakDD switcher leverages many
of the features found in the Thomson Grass Valley XtenDD™ and Zodiak™
switchers. The result is a compact system with superior image quality and
features not found in any other product.
Two basic models are available, the KayakDD-1 (one Mix Effects) switcher
and the KayakDD-2 (two M/E) switcher.
Features
•
Switchable between 525-line and 625-line formats
•
Fully digital 10-bit, 4:2:2 inputs, outputs, and video processing
•
Compact, lightweight frame (KayakDD-1 frame is 2 RU high, the
KayakDD-2 frame is 3 RU high)
•
Low power consumption
•
Intuitive menu with touch screen
•
Number of inputs: 16 for KayakDD-1, 32 for KayakDD-2
•
Five fixed outputs per M/E (2x PGM, 1x Preview, 1x Clean, 1x Clean
PVW), 5 outputs for Kayak DD-1, 10 outputs for KayakDD 2
•
Ten timed auxiliary buses
•
Four keyers per M/E, each with linear and luminance keying
•
Two standard Chroma Keyers
•
One Transform Engine
•
White or Colored keys (factory installed, choose when ordered)
KayakDD Installation Planning Guide
5
Introduction
Options
•
Internal frame RAM Recorder holds short clips and stills and works as
frame synchronizer
•
Additional Transform Engines (3)
•
Kurl effects package with Page Turn, Page Roll, Splits, Mirrors, and
Slits
•
RGB color correction (7)
•
Chromatte™ chroma keyers (2)
•
Remote monitoring support via NetCentral software
•
KDD-PSU redundant power supply unit
Supported Control Protocols
6
•
VTRs (BVW-75)
•
Servers (Louth VDCP, Odetics BVS)
•
Routers/Routing Control Systems (Trinix™, Venus™, Triton™, and
third party routers; Jupiter™ and Encore™ {future} router control systems)
•
Control Systems (Grass Valley Andromeda™ and third-party systems)
•
Grass Valley under monitor displays
•
Grass Valley external auxiliary panels
•
ESAM II for audio-follow-video applications
•
Edit controllers (native and Grass Valley Model 100 and 200)
KayakDD Installation Planning Guide
KayakDD-1 Installation
KayakDD-1 Installation
KayakDD-1 System Components
A KayakDD-1 Production Switcher system consists of a control panel with
integrated menu display (color TFT with touch-screen) and a 2 RU Video
Processor Frame.
Figure 1. KayakDD-1 Control Panel
Figure 2. KayakDD-1 Video Processor Frame
KayakDD Installation Planning Guide
7
KayakDD-1 Installation
KayakDD-1 Control Panel Installation
Measurements
8324_00_01_r0
Figure 3. Kayak DD-1 Control Panel Measurements 1 of 2
16.46 in.
418 mm
5.6
144 9 in.
.53
mm
20°
2.55 in.
64.75 mm
0.60 in.
15.3 mm
7°
3.19 in.
80.95 mm
0.40 in.
10.26 mm
8
10.23 in.
259.88 mm
1.31 in.
33.33 mm
15.66 in.
397.74 mm
0.39 in.
10 mm
KayakDD Installation Planning Guide
KayakDD-1 Installation
8324_02_r0
Figure 4. Kayak DD-1 Control Panel Measurements 2 of 2
0.39 in.
10 mm
16.85 in.
428 mm
0.39 in.
10 mm
17.64 in.
448 mm
15.46 in.
418 mm
17.64 in.
448 mm
KayakDD Installation Planning Guide
9
KayakDD-1 Installation
Panel Mounting Options
Table Top
The panel can be placed on a table. Gummed feet prevent accidental movement of the panel.
Surface Mount Cut Out Dimensions
Cut a 16.93 in. (430 mm) x 15.75 in. (400mm) hole in table top for surface
mounting.
CAUTION At least 2 inches (50mm) of open space at the rear of the panel below the
mounting surface is required for proper cable clearance and air flow.
Fastening to Table Top
Four M4 thread drillings are available for fastening the panel to a table top
(Figure 5).
Figure 5. KayakDD-1 Panel Mounting Drillings
10.55 in.
268 mm
2.95 in.
75 mm
0.2 in.
5 mm
edge to drilling
centerline
17.24 in.
438 mm
drilling centerline
8324_03_r0
Four M4 thread drillings
for panel fastening
10
0.2 in.
5 mm
KayakDD Installation Planning Guide
KayakDD-1 Installation
KayakDD-1 Video Processor Frame Installation
Measurements
Figure 6. KayakDD-1 Frame Dimensions
19.0 in.
482 mm
3.44 in.
87.5 mm
18.3 in.
465 mm
3.5 in.
89 mm
3.0 in.
76.2 mm
17.48 in.
444.05 mm
16.67 in.
423.4 mm
Air Flow
8324_04_r0
15.94 in.
404.9 mm
0.18 in.
4.5 mm
KayakDD Installation Planning Guide
11
KayakDD-1 Installation
Rack Mounting
Slide rails
Recommended for mobil applications!
Not part of delivery!
8324_05_r0
Figure 7. KayakDD-1 Rack Mounting
CAUTION Mounting using only the front rack angles is permitted for fixed installations.
Additional support, like slide rails, is required for mobile applications (flight
case, OB van).
12
KayakDD Installation Planning Guide
KayakDD-1 Installation
KayakDD-1 Cabling
Control Cabling
Figure 8. KayakDD-1 Standard Control Cabling
Mouse
Keyboard
Note:
Keyboard and Mouse not
manditory and not supplied.
Control Panel
48V DC
Power Supply
CAT5 Crossover Cable
alternatively
Video Processor Frame
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
AC POWER IN
DD
KAYAK
grass valley
100 - 240 V
(1) This device may not cause harmful interference, and
1 M/E DIGITAL SWITCHER
Port 1
(2) this device must accept any interference received, including interference that may cause undesired operation.
Port 2
Port 3
max. 4A
M/E
50/60 Hz
PGM-A
AUX
PVW-A
CLEAN
CLEAN-PVW
AUX 1
AUX 2
AUX 3
AUX 4
AUX 5
AUX 6
AUX 7
AUX 8
AUX 9
J 19
AUX 10
Port 4
J 20
Port 5
J5
J6
J8
J9
J 10
J 11
J 12
J 13
J 14
J 15
J 16
J 17
J 23
J 18
J 24
N4067
RS 485
For continued protection against risk
IN 2
of fire, repplace only with same type and rating of fuse.
J1
J7
J 21
Port 6
J 22
J4
Caution:
IN 4
IN 6
IN 8
IN 10
IN 12
IN 14
IN 16
ANALOG
LAN
2*T6,3A /H
R
250V
Listed
Prof. Vid. Equipm.
IN 3
J 26
IN 5
J 28
IN 7
J 30
IN 9
J 32
IN 11
J 34
IN 13
J 36
IN 15
J 38
3S13
J 40
GPI/O - Tally
J 42
J 41
J 25
J 27
J 29
J 31
INPUT
J 33
J 35
J 37
J 39
REFERENCE
+
J 43
IN
J2
-
DC POWER
48V / 5A max.
+
OUT
48V / 1,6A
Suplied DC Interconnect Cable
110-240V AC
Power Supply
J 44
48V DC
Power Supply
(Redudancy)
J3
8324_07_r0
IN 1
The KayakDD-1 system uses Ethernet, serial, parallel, and USB connections. Tally and GPI/O control are also available. A simple KayakDD-1
system consisting of a Control Panel and Video Processor frame uses pointto-point connections and does not require connection to an external
Ethernet Local Area Network (LAN).
Note
The point to point connection between the Control Panel and Video Processor
frame require swapped Transmit (TX) and Receive (RX) pairs. This is normally achieved with a crossover LAN cable or an Uplink port on a switch or
hub. The LAN cable supplied with the KayakDD system is a crossover cable.
A KayakDD system requires a LAN when components besides a Control
Panel and Video Processor frame are connected, or when external network
access to a file system is desired. An appropriately sized Ethernet switch
will be required. An existing facility Ethernet switch (not hub) can support
KayakDD if an adequate number of ports are available. Keep your facility
network and technical network separate in order to avoid network traffic
negatively affecting KayakDD system operation. An Ethernet hub or
switch will be necessary if cable runs exceed allowable maximums.
KayakDD Installation Planning Guide
13
KayakDD-1 Installation
Table 1 details Ethernet specifications. All Ethernet components are to be
supplied by the customer.
Table 1. Ethernet Specifications
Type
Cables
Connectors
Switch
10Base-T and 100Base-T compatible.
Category 5 cable, 8 conductor twisted pair.
The system will work at 10Base-T with reduced performance.
100Base-T components are highly recommended.
RJ-45 male connector at each end of cable.
Length
10Base-T: 984 ft. (300 m) maximum.
100Base-T: 328 ft. (100 m) maximum.
Use hub or switch to exceed maximum cable runs.
Speed
Dual: 10 and 100 Mb
Ports
RJ-45 auto-negotiating 10/100 Mb; number of ports required is
dependent upon system size.
Unmanaged
Recommended. Configuration not required, but does not provide
remote monitoring capability.
Managed
May be used. Require configuration, but offers remote monitoring
capability.
Video Cabling
All KayakDD system video inputs and Aux outputs are configurable. For
cabling configuration flexibility, each input can be mapped to any
KayakDD panel source select button, and any KayakDD system video
signal can be mapped to any AUX output connectors.
Inputs
Non-looping video inputs on the back of the Video Processor frame are
numbered 1 through 16. Each receives a 270 MHz serial digital video signal.
Each input can be mapped to any KayakDD panel source select button.
Outputs
The KayakDD frame provides dedicated program and preview video
output connectors for the M/E. The main program output signal is available on two BNC connectors. All other outputs are available on one BNC
connector only. Any KayakDD video source can be routed to any Aux bus
output (1 through 10).
Reference Input
The looping reference input accepts analog 525 or 625 composite video.
Burst is not required, but typically facility reference color black is used.
KayakDD can auto-sense whether the reference is 525 or 625 and can
change the internal standard accordingly.
14
KayakDD Installation Planning Guide
KayakDD-2 Installation
KayakDD-2 Installation
Kayak DD-2 System Components
A KayakDD-2 Production Switcher system consists of a control panel with
integrated menu display (color TFT with touch-screen) and a 3 RU Video
Processor Frame.
Figure 9. KayakDD-2 Control Panel
Figure 10. KayakDD-2 Video Processor Frame
KayakDD Installation Planning Guide
15
KayakDD-2 Installation
Kayak DD-2 Control Panel Installation
Measurements
8324_08_r0
Figure 11. Kayak DD-2 Control Panel Measurements 1of 2
16.46 in.
418 mm
5.6
144 9 in.
.53
mm
3.19 in.
80.95 mm
0.40 in.
10.26 mm
16
20°
0.60 in.
15.3 mm
1.31 in.
33.33 mm
7°
2.55 in.
64.75 mm
10.23 in.
259.88 mm
15.66 in.
397.74 mm
0.39 in.
10 mm
KayakDD Installation Planning Guide
KayakDD-2 Installation
8324_09_r0
Figure 12. Kayak DD-2 Control Panel Measurements 2 of 2
0.39 in.
10 mm
31.1 in.
789 mm
0.39 in.
10 mm
31.9 in.
809 mm
16.5 in.
418 mm
31.9 in.
809 mm
Panel Mounting Options
Table Top
The panel can be placed on a table. Gummed feet prevent accidental movement of the panel.
Surface Mount Cut Out Dimensions
Cut a 31.2 in. (791mm) x 15.75 in. (400 mm) hole in table top for surface
mounting.
KayakDD Installation Planning Guide
17
KayakDD-2 Installation
CAUTION At least 2 inches (50mm) of open space at the rear of the panel below the
mounting surface is required for proper cable clearance and air flow.
Fastening to Table Top
Four M4 thread drillings are available for fastening the panel to a table top
(Figure 13).
Figure 13. KayakDD-2 Panel Mounting Drillings
0.2 in.
5 mm
edge to drilling
2.95 in.
centerline
75 mm
10.55 in.
268 mm
31.46 in.
799 mm
drilling centerline
0.2 in.
5 mm
18
KayakDD Installation Planning Guide
KayakDD-2 Installation
Frame
Measurements
Figure 14. KayakDD-2 Frame Dimensions
19.0 inch
482 mm
18.3 inch
465 mm
2.25 inch
57.15mm
5.2 inch
132.95 mm
17.2 inch
438 mm
0.3inch
7.5mm
KayakDD Installation Planning Guide
15.6 inch
420.74 mm
8324_11_r0
15.5 inch
401.9 mm
19
KayakDD-2 Installation
Rack Mounting
Figure 15. KayakDD-2 Rack Mounting
Air Flow
Air
Flow
Slide rails.
Recommended for mobil applications.
Not part of delivery.
CAUTION Mounting using only the front rack angles is permitted for fixed installations.
Additional support, like slide rails, is required for mobile applications (flight
case, OB van).
20
KayakDD Installation Planning Guide
KayakDD-2 Installation
Cabling
FIGURE shows the basic control cabling of a KayakDD-2 system.
Figure 16. KayakDD-2 Standard Control Cabling
Keyboard
Mouse
3
P/S 2
Note:
Keyboard and Mouse not
manditory and not supplied.
4
USB
Control Panel
48V DC
Power Supply
(Redudancy)
CAT5 Crossover Cable
Suplied DC Interconnect Cable
Video Processor Frame
grass valley
grass valley
TYPE
KAYAK DD-2
PART NO. 0 212 390 010
SER. NO. 100
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.Port 1
DD-2
KAYAK
2 M/E DIGITAL SWITCHER
P/P
PGM
Port 2
Port 3
AUX 1-10
PVW
CLEAN
CLEAN-PVW
AUX 1
AUX 2
AUX 3
AUX 4
AUX 5
AUX 6
AUX 7
AUX 8
AUX 9
J 19
AUX 10
Port 4
J 20
Port 5
J4
J5
J6
J7
J8
IN 1
J9
IN 4
IN 2
J 10
IN 6
IN 5
IN 3
J 26
J 28
J 11
J 12
IN 8
IN 7
J 30
J 13
IN 10
J 14
IN 9
IN 11
J 32
J 15
IN 12
J 34
J 16
IN 14
IN 13
J 17
IN 16
J 38
J 23
J 24
RS 485
J 18
LAN
ANALOG
IN 15
J 36
J 21
Port 6
J 22
GPI/O - Tally
J 42
J 40
J 43
J 44
AC POWER IN
J1
2*T6,3A /H
250V
R
J 41
J 27
J 29
J 31
J 45
DC POWER
J 46
INPUT 1-16
J 47
J 33
J 35
J 48
J 37
J 39
REFERENCE
J 49
INPUT 17-32
IN 17
IN
Listed
Prof. Vid. Equipm.
3S13
N4067
IN 18
IN 19
IN 20
IN 21
IN 22
IN 23
IN 24
48V / 5A max.
J2
PGM
OUT
PVW
CLEAN
CLEAN-PVW
J 50
IN 25
IN 26
J 51
IN 27
J 52
IN 28
J 53
IN 29
J 54
IN 30
J 55
IN 31
J 56
J 57
IN 32
M/E
48V / 1,6A
J3
110-240V AC
Power Supply
J 58
J 59
J 60
J 61
J 62
J 63
J 64
J 65
8324_13_r0
100 - 240 V
max. 4A
50/60 Hz
J 25
Caution: For continued protection against risk
of fire, repplace only with same type and rating of fuse.
48V DC
Power Supply
(Redudancy)
The KayakDD-2 system employs the same type of control and video
cabling as the KayakDD-1 system, except it has 32 video inputs and 20 outputs. Refer to KayakDD-1 Cabling on page 13 for details.
KayakDD Installation Planning Guide
21
KDD-PSU Power Supply Option
KDD-PSU Power Supply Option
The KDD-PSU option is a one rack unit, wide range AC power supply providing redundant power for KayakDD production switcher. Power output
is sufficient for two KayakDD-1 systems or one KayakDD-2 system.
Note
To ensure sufficient RAM Recorder buffer voltage, the cable length is limited
to 20 m. Standard KayakDD cables are not suitable for buffer voltage supply.
Installation
8324_14_r0
Figure 17. KDD-PSU Rack Installation
Cut fastening metal so that the
ventilation openings are not covered
22
KayakDD Installation Planning Guide
Pin Assignments
Pin Assignments
RS 485 Port
Socket
D-9 Female
Pin 5
Pin 1
Pin 9 Pin 6
Pin
Bus Controller
Tributary
1
Chassis Ground
Chassis Ground
2
RxA (-)
TxA (-)
3
TxB (+)
RxB (+)
4
Signal Ground
Signal Ground
5
Not used
Not used
6
Signal Ground
Signal Ground
7
RxB (+)
TxB (+)
8
TxA (-)
RxA (-)
9
Chassis Ground
Chassis Ground
RS 232 Port
Socket
D-9 Female
Pin 5
Pin 1
Pin 9 Pin 6
Pin
Signal
1
Chassis Ground
2
Transmit Data
3
Receive Data
4
Not used
5
Signal Ground
6
Not used
7
Clear to Send
8
Request to Send
9
Not used
Control Panel DC Power In
Socket
Pin
Signal
A1
48 V (+)
D-Sub Male
A2
48 V (-)
Pin 1
1
-
2
-
3
-
Pin A1
Pin 3
KayakDD Installation Planning Guide
Pin 2
Pin A2
Pin 5
4
-
5
-
23
Pin Assignments
Frame DC Power In
Socket
A1
48 V (+)
D-Sub Male
A2
48 V (-)
Pin 1
1
Ground
2
Return Sense *
3
+ 7 V (RAM Rec)
4
-
Pin A1
Pin 3
Note
Pin Signal
Pin 2
Pin A2
Pin 5
48V Return *
5
Pins 2 and 5 must be connected in the plug of the external power supply unit.
Frame DC Power Out
Table 2.
Socket
A1
48 V (+)
D-Sub Female
A2
48 V (-)
Pin 2
1
-
2
-
3
-
4
-
5
-
Pin A2
Pin 5
24
Pin Signal
Pin 1
Pin A1
Pin 3
KayakDD Installation Planning Guide
Pin Assignments
Frame GPI/O – Tally
Socket
Ribbon Cable
D-50 Female
Pin 18
Pin 1
Pin 34
Pin 33
Pin 17
Pin 50
KayakDD Installation Planning Guide
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
50-Pin D-Sub
1
34
18
2
35
19
3
36
20
4
37
21
5
38
22
6
39
23
7
40
24
8
41
25
9
42
26
10
43
27
11
44
28
12
45
29
13
46
30
14
47
31
15
48
32
16
49
33
17
50
Signal
GPIInCom
GPIInCom
GPIIn1
GPIIn2
GPIIn3
GPIIn4
GPIIn5
GPIIn6
GPIIn7
GPIIn8
GPIOutComA
GPIOut1A
GPIOut2A
GPIOut3A
GPIOut4A
GPIOutComB
GPIOut5B
GPIOut6B
GPIOut7B
GPIOut8B
GPIOutComC
GPIOut9C
GPIOut10C
GPIOut11C
GPIOut12C
GPIOutComD
GPIOut13D
GPIOut14D
GPIOut15D
GPIOut16D
GPIOutComE
GPIOut17E
GPIOut18E
GPIOut19E
GPIOut20E
GPIOutComF
GPIOut21F
GPIOut22F
GPIOut23F
GPIOut24F
GPIOutComG
GPIOut25G
GPIOut26G
GPIOut27G
GPIOut28G
GPIOutComH
GPIOut29H
GPIOut30H
GPIOut31H
GPIOut32H
25
Specifications
Specifications
Table 3. Mechanical
KayakDD-1 Video Processor Frame
Height 2RU
89 mm
3.5 inch
Width
482 mm
19 inch
Depth
430 mm
17 inch
Weight
6.5 kg
14.3 lbs
Width
448 mm
17.6 inch
Depth
418 mm
16.5 inch
Mounting Depth
33 – 81 mm
1.3 - 3.2 inch
Weight
7 kg
15.4 lbs
Height 3 RU
134 mm
5.3 inch
Width
482 mm
19 inch
KayakDD-1 Control Panel
KayakDD-2 Video Processor Frame
Depth
430 mm
17 inch
Weight
8.3 kg
18.3 lb
Width
809 mm
31.8 inch
Depth
418 mm
16.5 inch
Mounting Depth
33 – 81 mm
1.3 - 3.2 inch
Weight
10 kg
22 lb.
KayakDD-2 Control Panel
KDD-PSU Power Supply Option Frame
Height 1RU
44 mm
1.73 inch
Width
482 mm
19 inch
Depth
240 mm
9.45 inch
Weight
2.8 kg
6.2 lb.
Table 4. Environmental
Storage temperature
-20∞C to +70∞C (-4∞F to 158∞F)
Operating temperature
+5∞C to +40∞C (41∞F to 104∞F)
Relative humidity
£ 95% non-condensing
Electromagnetic environment
E2 (according to EN55103-1, -2)
Table 5. Control Panel Connection
Type of connection
10/100 Base T
Protocol
TCP(UDP)/IP as in XtenDD
Cable and connectors
CAT5 UTP, RJ45 connectors;
max. Cable length
100m / 300ft
1 Frame and 1 Panel connect without use of external hub/switch.
26
KayakDD Installation Planning Guide
Specifications
Table 6. Power
KayakDD-1 Frame
Line voltage
100V-240V AC +/-10% autorange, power factor corrected (48V / 5A
DC Input for ext. redundancy)
Line frequency
50/60Hz +/- 5%
Power consumption
max. 150W (max. 200W with 48V DC supply for panel)
Leakage current
< 2.5 mA
RAMRecorder buffer voltage:
6..8V DC approx. 150 mA.
DC-OUT for control panel
48V DC, max 1.6A
KayakDD-1 Control Panel
DC-IN
48V DC In, max 1.3A
Power consumption
max. 50W
KayakDD-2 Frame
Line voltage
100V-240V AC +/-10% autorange, power factor corrected (48V / 5A
DC Input for ext. redundancy)
Line frequency
50/60Hz +/- 5%
Power consumption
max. 250W (max. 310W with 48V DC supply for panel)
Leakage current
< 2 mA
RAMRecorder buffer voltage: .
6…8V DC approx. 150 mA
DC-OUT for control panel
48V DC, max 1.6A
KayakDD-2 Control Panel
DC-IN
48V DC In, max 1.3A
Power consumption
max. 60W
KDD-PSU Frame
Line voltage
100V-240V AC +/-10%, power factor corrected
Line frequency
50/60Hz +/- 5%
Power consumption
max. 375W
Leakage current
< 2 mA at 250V AC
DC-OUT
2x 48V DC, total 6A max
EXT BATT IN
12V … 24V, 0.5A
RAM Recorder buffer voltage:
7V DC, max 300mA. (Only with ext. battery input or AC In)
KayakDD Installation Planning Guide
27
Specifications
Table 7. Serial Digital Video Inputs
Format
Number of Inputs
Return loss
ITU-R656, 270Mbit/s
KayakDD-1: 16
KayakDD-2: 32
> 15dB, 5-270MHz
Type of Connector
75 ohm BNC (SMPTE 259M)
Nominal Amplitude
800mV peak-to-peak terminated
Autophasing range
53 msec
Channel Coding
conforms to SMPTE RP-259M
Ancillary Data
Blanked or passed (user selectable)
Embedded audio
Blanked or passed (user selectable)
EDH
Blanked
Input Impedance
75 ohm
Max cable length
225 meters (738ft)
Table 8. Serial Digital Video Outputs
Format
Number of Outputs
ITU-R656, 270Mbit/s
KayakDD-1: 15
KayakDD-2: 20
Return loss
> 15dB, 5-270MHz
Type of Connector
75 ohm BNC (SMPTE 259M)
Nominal Amplitude
800mV peak-to-peak +/-10% (SMPTE 259M)
Rise & Fall Times
400 to 1400picoseconds 75 ohm termination
between 20% and 80% amplitude
Jitter
ITU R 601/656
Output Impedance
75 ohm
DC Offset
< 50mV with 75 ohm termination
Table 9. Analog Reference Input
28
Video Standard
525 line (59.94Hz/60Hz) or 625 line (50Hz) BNC, 0.3V sync,
black-burst or CCVS
Return loss
> 40dB, up to 5MHz
Connectors
2 BNC loop through
Impedance
75 ohm external
KayakDD Installation Planning Guide