DataVideo ITC-100 video capture board Datasheet

Add to my manuals
16 Pages

advertisement

DataVideo ITC-100 video capture board Datasheet | Manualzz

ITC­100 

8 Channel Intercom / Talkback 

System 

User’s Guide 

Rev: 300506

http:// www.datavideo­tek.com 

Warnings and Precautions 

1.  Read all of these warnings and save them for later reference. 

2.  Follow all warnings and instructions marked on this unit. 

3.  Unplug this unit from the wall outlet before cleaning. Do not use liquid or aerosol cleaners. Use a  damp cloth for cleaning. 

4.  Do not use this unit in or near water. 

5.  Do not place this unit on an unstable cart, stand, or table. The unit may fall, causing serious  damage. 

6.  Slots and openings on the cabinet top, back, and bottom are provided for ventilation. To ensure  safe and reliable operation of this unit, and to protect it from overheating, do not block or cover  these openings. Do not place this unit on a bed, sofa, rug, or similar surface, as the ventilation  openings on the bottom of the cabinet will be blocked. This unit should never be placed near or  over a heat register or radiator. This unit should not be placed in a built­in installation unless  proper ventilation is provided. 

7.  This product should only be operated from the type of power source indicated on the marking  label of the AC adapter. If you are not sure of the type of power available, consult your Datavideo  dealer or your local power company. 

8.  Do not allow anything to rest on the power cord. Do not locate this unit where the power cord will  be walked on, rolled over, or otherwise stressed. 

9.  If an extension cord must be used with this unit, make sure that the total of the ampere ratings  on the products plugged into the extension cord do not exceed the extension cord’s rating. 

10.  Make sure that the total amperes of all the units that are plugged into a single wall outlet do not  exceed 15 amperes. 

11.  Never push objects of any kind into this unit through the cabinet ventilation slots, as they may  touch dangerous voltage points or short out parts that could result in risk of fire or electric shock. 

Never spill liquid of any kind onto or into this unit. 

12.  Except as specifically explained elsewhere in this manual, do not attempt to service this product  yourself. Opening or removing covers that are marked “Do Not Remove” may expose you to  dangerous voltage points or other risks, and will void your warranty. Refer all service issues to  qualified service personnel. 

13.  Unplug this product from the wall outlet and refer to qualified service personnel under the  following conditions:  a.  When the power cord is damaged or frayed;  b.  When liquid has spilled into the unit;  c.  When the product has been exposed to rain or water;  d.  When the product does not operate normally under normal operating conditions. Adjust  only those controls that are covered by the operating instructions in this manual;  improper adjustment of other controls may result in damage to the unit and may often  require extensive work by a qualified technician to restore the unit to normal operation;  e.  When the product has been dropped or the cabinet has been damaged;  f.  When the product exhibits a distinct change in performance, indicating a need for  service.

1 

Warranty 

Datavideo warrants that the equipment it manufactures shall be free from defects in material and  workmanship for a period of 12 months from the date of product purchased. If equipment fails due to  such defects, Datavideo will, at its option, repair or provide a replacement for the defective part or  product. 

Equipment that fails after the warranty period, has been operated or installed in a manner other than  that specified by Datavideo, or has been subjected to abuse or modification, will be repaired for time  and material charges at the Buyer’s expense. This warranty does not affect your statutory rights  within the Country of purchase. 

For EU Customers only ­ WEEE Marking. 

This symbol on the product indicates that it will not be treated as household waste. It must be handed  over to the applicable take­back scheme for the recycling of electrical and electronic equipment. For  more detailed information about the recycling of this product, please contact your local Datavideo  office. 

Introduction 

The ITC­100 is a 19” Rack Mount 8 Way Intercom / Talkback System. It  incorporates tally indicators for each channel and individual channel call buttons as  well as a call all channels button. 

It is ideal in a live environment and enables easy bi­directional communication  between all members of the crew. It is a perfect accessory for the Datavideo 

SE­800 and SE­500 vision mixers.

2 

Contents 

WARNINGS AND PRECAUTIONS 

WARRANTY 

INTRODUCTION 

WHAT’S IN THE PACKAGE 

FRONT PANEL CONNECTIONS 

REAR PANEL CONNECTIONS 

ITC­100SL SLAVE UNIT 

USING THE ITC­100 WITH THE SE­800 / RMC­140 

USING THE ITC­100 WITH THE SE­800 / RMC­90 

USING THE ITC­100 WITH THE SE­500 

ITC­100 TALLY INPUT PIN CROSS REFERENCE 

SPECIFICATIONS 

SERVICE AND SUPPORT 

What’s in the Package 

1.  ITC­100 main unit 

2.  ITC­100SL Slave Unit  x  1  x  4 

3.  ITC­100SL Carrying Case  x  4 

4.  20m XLR to XLR Intercom Cable  x  4 

5.  MC­1 Headset / Microphone 

6.  MC­2 XLR Gooseneck Mic 

7.  LP­1 XLR Gooseneck Light 

8.  12V 2.5A Power Supply Unit 

9.  AC Power cord. 

10. User’s Guide  x  x  x  x  x  x 

1

3 

10 

11 

12 

13 

15 

Front Panel: 

On / Off Switch 

Powers the ITC­100 On / Off. Red LED indicates that unit is switched  on. 

XLR Microphone Socket 

Combined XLR / ¼” (6.3mm) Jack Microphone Input for either a 

Condenser or Dynamic Gooseneck Microphone. XLR supports 

Condenser Microphones ¼” (6.3mm) Jack supports Dynamic. 

Headphone Socket 

¼ “ / 6.3mm Stereo Headphone Socket for conventional headphones. 

Plugging in headphones will disable the built­in speaker 

Microphone / Headset Socket 

3.5mm Stereo Socket for combined Microphone Headset. 

Plugging in a Microphone / Headset will disable the built­in speaker and  the XLR Microphone Input. 

ALL Button 

Opens communication with all channels. All channels will hear  communication from the operator, or from any other channel using the 

TALK button.

4 

Channel Buttons 1~8 

Opens communication with individual channels. More than 1 channel  can be active at any given time, active channels are illuminated red. 

All active channels will hear any communication from the operator or  from any other active channel. 

The buttons will also indicate if any channel is paging, the paging  channel will flash in orange until the page is answered. 

MUTE Button 

Mutes all communication from the base station or any channel. 

N.B. If any channel uses the CALL button the paging tone will still 

sound even when the MUTE button is active. 

Volume Control 

Controls the Volume of the built­in speaker or outputs to the  headphones or mic/headset according to what is connected 

Built­In Speaker 

Sounds audible alert when a channel is paging and provides audio  during talkback conversations. Speaker is mute when headphones or  mic / headset are connected to the ITC­100 

12V Light Socket 

12V Powered light socket for gooseneck light (supplied).

5 

Rear Panel: 

Channel Input / Output XLR Sockets 

Each of the 8 channels has an XLR connector that carries  bi­directional signals between the ITC­100 and ITC­100SL. All  connections are contained within the one cable. Channels 1 ~ 4  are supplied tally light information from tally A; channels 5 ~ 8  are supplied tally light information from tally B. 

Tally Inputs A & B 

Tally Inputs A & B are configured for direct connection to the 

Datavideo RMC­140, RMC­90 or SE­500. They supply bi­color  tally information to the ITC­100SL; RED indicates Live and 

AMBER indicates Cued. Tally A will feed information to  channels 1 ~ 4 and Tally B will feed information to channels 5 ~ 

8 

DC In 12V 1.5A 

Connect the 12V 1.5A power supply. The power supply plug  has a screw in locking collar to secure the connection. 

Ground Terminal 

When connecting this unit to any other component, make sure  that it is properly grounded by connecting this terminal to an  appropriate point. When connecting, use the socket and be sure  to use wire with a cross­sectional area of at least 1.0 mm2.

6 

ITC­100SL Slave Unit : 

XLR Connection 

Connects the ITC­100SL to the ITC­100 Base Station. Power, tally and  bi­directional audio are all carried through the same cable. 

Call Button 

Sends a paging message to the ITC­100 Base Station. The channel button  will flash orange and there will be an audible tone, each time the button is  pressed. 

Bi­Color Tally LED 

Will illuminate RED when the channel is LIVE and AMBER when the  channel is CUED 

Talk Button 

Opens up talk back communication with the ITC­100 base station, and any  other active channels. 

Volume Control 

Adjusts the volume of the headphones.

7 

Mic / Headphone Socket 

The ITC­100SL has both a 3.5mm and 2.5mm Mic / Headset socket. A  standard 3.5mm Mic / Headset can be used, or a Motorola type 2.5mm Mic /  headset could be used if preferred. 

External Tally LED Socket 

An external tally display (TD­1) can be connected to the ITC­100SL. This  enables the tally light to be positioned in a more convenient place, such as  on top of the camera. When the channel is LIVE the LED will be RED, and  when the channel is CUED the LED will be AMBER. 

N.B. The Tally LED on the ITC­100SL will continue to operate as normal 

when a TD­1 has been added. 

Power LED 

The Power LED indicates when the channel is active. If the operator has  opened the channel by pressing the channel button 1 ~ 8, or by pressing 

ALL then the LED will light up. 

N.B. The tally indicator lights will continue to work even when the 

Power LED is not on, and the channel is not active.

8 

Using the ITC­100 with the SE­800 / RMC­140: 

The ITC­100 is an ideal accessory for the Datavideo SE­800 / SE­800AV Vision 

Mixer. The SE­800 has four channels, so in the diagram below we have four  camera crew, each with an ITC­100SL 

The RS­232 output from the SE­800 connects to the RMC­140; this provides the  status of the SE­800. The RMC­140 Tally Out connects to the ITC­100 Tally Input A. 

Tally Input A provides tally information to channels 1 ~ 4. When the camera is live  the cameraman will see a red light, when a camera is cued up the cameraman will  see an amber light.

9 

Using the ITC­100 with the SE­800 / RMC­90: 

Using the Datavideo SE­800 / SE­800AV Vision Mixer in combination with the 

RMC­90 remote control makes live production really simple. 

The RS­232 output from the SE­800 connects to the RMC­90; this provides the  status of the SE­800. The RMC­90 Tally Out connects to the ITC­100 Tally Input A. 

Tally Input A provides tally information to channels 1 ~ 4. When the camera is live  the cameraman will see a red light, when a camera is cued up the cameraman will  see an amber light.

10 

Using the ITC­100 with the SE­500: 

The ITC­100 is an ideal accessory for the Datavideo SE­500 Vision Mixer. The 

SE­500 has four channels, so in the diagram below we have four camera crew,  each with an ITC­100SL. 

The SE­500 Tally Out connects to the ITC­100 Tally Input A. Tally Input A provides  tally information to channels 1 ~ 4. When the camera is live the cameraman will see  a red light, when a camera is cued up the cameraman will see an amber light.

11 

ITC­100 Tally Input ­ Pin Cross Reference 

If you are using the ITC­100 with a Datavideo RMC­140, RMC­90 or SE­500 you do  not need to worry about tally information, as it is automatically sent to the ITC­100. 

If you are using the ITC­100 with other equipment the following tables explain the  pin configurations of Tally A and Tally B. 

Contact closure between the relevant Pin number and ground will illuminate the 

LED. For example on Tally A, if Pin 1 is connected to Pin 4 the RED LED will light  up on Channel 1; if Pin 13 is connected to Pin 4 the AMBER LED will light up on 

Channel 3 

Tally A Input 

The Tally A Input will send Tally Information to Channels 1 ~ 4. The following table  shows the pin numbers for each channel: 

Video 

Channel 

Red LED 

LIVE 

(On Air) 

Pin 1  1 

2 

3 

Pin 6 

Pin 11 

4  Pin 5 

Pins 4, 9 and 14 can be used as ground. 

Amber LED 

CUED 

(Next) 

Pin 3 

Pin 8 

Pin 13 

Pin 15 

Tally B Input 

The Tally B Input will send Tally Information to Channels 5 ~ 8. The following table  shows the pin numbers for each channel: 

Video 

Channel 

Red LED 

LIVE 

(On Air) 

Pin 1  5 

6 

7 

Pin 6 

Pin 11 

8  Pin 5 

Pins 4, 9 and 14 can be used as ground. 

12 

Amber LED 

CUED 

(Next) 

Pin 3 

Pin 8 

Pin 13 

Pin 15

Specification: 

ITC­100 Base Station  Specification 

POWER 

TALLY 

12V 1.5A 

2 x 15 Pin SubD Sockets for Tally A and Tally B 

MIC / HEADSET  3.5mm Stereo Jack Socket for combination 

Headphone / Microphone 

Headset Impedance 8~600 ohms 100mW(min) 

INPUTS / 

OUTPUTS 

HEADPHONE  ¼” (6.3mm) Stereo Headphone Socket 

Headset Impedance 8~600 ohms 100mW(min) 

LIGHT SOCKET 

(12V DC) 

MICROPHONE 

FREQUENCY RESPONSE 

3 pin XLR connector. Pin2: 12V, Pin3: GND. 

Light power consumption 12V/100mA(max). 

3 Pin XLR / ¼” (6.3mm) Jack Microphone 

Socket Switchable Condenser / Dynamic Input 

Microphone Level ­67dB 

550­3.6KHz, < +/­3dB 

THD 

S/N 

BUILT­IN SPEAKER 

OPERATING RANGE 

< 3% 

> 50dB 

70mm x 30mm 32 Ohm 3 Watts 

Up to 200m between Base Station and Slave 

OPERATING TEMP. RANGE  5 ~ 45°C 

DIMENSION 

WEIGHT 

750mm x 650mm x 250mm (1U height 19”  rack) 

1.9Kg

13 

ITC­100SL SLAVE Unit 

INPUT 

Specification 

5 Pin XLR Connector 

MIC / HEADSET SOCKET 

TALLY OUT SOCKET 

TALLY LED 

POWER LED 

OPERATING RANGE 

3.5mm Stereo Jack Socket for combination 

Headphone / Microphone 

Headset Impedance 8~600 ohms 100mW(min) 

Microphone Level ­67dB

Or 

2.5mm Stereo Jack Socket, for Motorola Mobile 

Phone type headset / microphone 

3.5mm Jack Socket to connect to TD­1 Tally 

Indicator 

Bi­Color LED – RED indicates LIVE / AMBER 

Indicates CUED 

Illuminates to indicate that power is being  received 

Up to 200m between Base Station and Slave 

OPERATING TEMP. RANGE  5 ~ 45°C 

DIMENSION 

WEIGHT 

114mm x 97mm x 35mm 

348g

14 

Service and Support 

It is our goal to make your products ownership a satisfying experience. Our  supporting staff is available to assist you in setting up and operating your system. 

Please refer to our web site www.datavideo­tek.com for answers to common  questions, support requests or contact your local office below. 

Datavideo Corporation (USA) 

12300­U East Washington Blvd., Whittier, CA 90606 USA 

Tel: +1 562 696 2324  [email protected]  www.datavideo.us 

Datavideo Technologies Europe BV 

Californiedreef 26    3565 BL Utrecht, The Netherlands 

Tel: +31 30 261 9656  [email protected]  www.datavideo.info 

Datavideo UK Limited 

Unit 2 Waterside Business Park, Hadfield, Glossop, Derbyshire SK13 1BE UK 

Tel: +44 1457 851000  [email protected]  www.datavideo.info 

Datavideo Technologies Co., Ltd. 

10F, 176 Jian­Yi Rd, Chung Ho City, Taipei Hsien, Taiwan 235 

Tel: +886 2 8227 2888  [email protected]  www.datavideo.com.tw 

Datavideo Technologies China Co. 

2F­D, 2 Lane 777, West Guangzhong Rd, Zhabei District, Shanghai, China 

Tel: +86 21 5603 6599  [email protected]  www.datavideo.cn 

Datavideo Technologies (S) PTE Ltd. 

No. 100, Lorong 23 Geylang, #01­03 D’Centennial Bldg, Singapore 388398 

Tel: +65 6749 6866  [email protected]  www.datavideo.info 

Datavideo Hong Kong Limited 

G/F., 26 Cross Lane, Wanchai, HK 

Tel: +852 2833 1981  [email protected]  www.datavideohk.com

15 

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement