advertisement
From the
IOTA Power Products
Technical Library
Charging for 6-Volt Battery Systems
Balanced charging for 6-volt batteries in 12-volt configurations
IOTA DLS 12-volt models can be used to charge 6-volt batteries when they are configured in a 12-volt “series” arrangement. If several “series” groups are combined for larger capacity, the DLS can provide balanced charging (ie. delivering the same charging voltage) to all the batteries by referring to Diagram #2.
Diagram #1
6-Volt Batteries in Series
Two 6-volt batteries can be connected in series to increase the combined output voltage to
12Vdc. The battery capacity (AH) will remain unchanged. In this scenario, the DLS charger is connected to the POS (+) terminal on one battery and the NEG (-) terminal on the other. Each connection is equally balanced with one another in this arrangement.
6V
6V
(2) 6-volt batteries in series = 12 volts
Diagram #2:
6-Volt Series/Parallel
Combination
A 6-Volt Battery Series/Parallel configuration connects two
6-Volt Series arrangements in parallel. This maintains the
12-volt output but doubles the overall battery capacity. In this scenario, balanced charging is achieved by connecting to the
POS (+) terminal on one series group and the NEG (-) on the other series group as shown.
6V
6V
6V
6V
Note that for optimal battery bank and charging performance, the batteries in the bank should be of the same manufacturer and model, as well as the same AH rating, age, condition, and state of charge [SOC]. For additional assistance with using IOTA DLS chargers for your 6-volt battery applications, contact our Technical Services team at
1-855-363-9527 or visit www.iotaengineering.com/services.
IOTA Engineering 1361 E. Wieding Rd Tucson, AZ 85706 1-800-866-4682 www.iotaengineering.com
Rev. 040617