Belden 9463.00U305 coaxial cable Datasheet
Add to My manualsadvertisement
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
9463 Twinax - Blue Hose® Cable
For more Information please call
1-800-Belden1
Description:
20 AWG stranded (7x28) .038" tinned copper conductors, polyethylene insulation, Beldfoil® (100% coverage) plus a tinned copper braid shield (55% coverage), sunlight-resistant PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material Dia. (in.)
1 20 7x28 TC - Tinned Copper .038
Insulation
Insulation Material:
Insulation Material
PE - Polyethylene
Outer Shield
Outer Shield Material:
Layer # Outer Shield Trade Name Type Outer Shield Material
1 Beldfoil®
Coverage (%)
Tape Aluminum Foil-Polyester Tape 100
2 Braid TC - Tinned Copper 55
Outer Shield Drain Wire AWG:
AWG Stranding Drain Wire Conductor Material
20 7x28H TC - Tinned Copper
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVC - Polyvinyl Chloride
Overall Cabling
Overall Nominal Diameter:
Pair
Pair Color Code Chart:
Number Color
1 Clear & Blue
0.238 in.
Mechanical Characteristics (Overall)
Operating Temperature Range:
UL Temperature Rating:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius (Install)/Minor Axis:
-40°C To +80°C
80°C (UL AWM Style 2464)
36 lbs/1000 ft.
48 lbs.
2.500 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
CEC/C(UL) Specification: CM
AWM Specification: UL Style 2464 (300 V 80°C)
Page 1 of 3 01-27-2010
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
AWM Specification:
EU CE Mark:
EU Directive 2000/53/EC (ELV):
EU Directive 2002/95/EC (RoHS):
EU RoHS Compliance Date (mm/dd/yyyy):
EU Directive 2002/96/EC (WEEE):
EU Directive 2003/11/EC (BFR):
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
PMSHA Specification:
UL Style 2464 (300 V 80°C)
Yes
Yes
Yes
01/01/2005
Yes
Yes
Yes
Yes
P-7K-SC-182141
Customer Part Number Reference Specification: Allen Bradley P/N 1770-CD
Flame Test
UL Flame Test:
Suitability
Sunlight Resistance:
UL1685 UL Loading
Yes
Plenum/Non-Plenum
Plenum Number: 89463
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm)
78
Nom. Inductance:
Inductance (µH/ft)
0.12
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/ft)
19.7
Nom. Capacitance Cond. to Other Conductor & Shield:
Capacitance (pF/ft)
36
Nominal Velocity of Propagation:
VP (%)
66
Nominal Delay:
Delay (ns/ft)
1.54
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
9.5
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
4.1
Nom. Attenuation:
Freq. (MHz) Attenuation (dB/100 ft.)
1 0.6
10
50
2.1
5.0
100
200
7.5
11.0
Page 2 of 3
9463 Twinax - Blue Hose® Cable
01-27-2010
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
9463 Twinax - Blue Hose® Cable
400 16.0
Max. Operating Voltage - UL:
Voltage
300 V RMS (UL AWM Style 2464)
Other Electrical Characteristic 1: DC Resistance Unbalanced: .77 Ohms/1000 ft Max
Put Ups and Colors:
Item #
9463 J22U1000
9463 J22U500
9463 J22100
9463 J221000
9463 J22500
9463 J226000
9463 0011000
9463 00110000
9463 0016000
9463 0031000
9463 00310000
9463 0036000
9463 0071000
9463 0076000
Putup
1,000 FT
500 FT
100 FT
1,000 FT
500 FT
6,000 FT
1,000 FT
10,000 FT
6,000 FT
1,000 FT
10,000 FT
6,000 FT
1,000 FT
6,000 FT
Ship Weight
38.000 LB
19.500 LB
4.400 LB
39.000 LB
18.000 LB
234.000 LB
39.000 LB
380.000 LB
234.000 LB
39.000 LB
380.000 LB
234.000 LB
39.000 LB
234.000 LB
Color
BLUE, STRONG
BLUE, STRONG
BLUE, STRONG
BLUE, STRONG
BLUE, STRONG
BLUE, STRONG
BROWN
BROWN
BROWN
ORANGE
ORANGE
ORANGE
VIOLET
VIOLET
Notes
C
C Z
C Z
C Z
C
C Z
C Z
C
C Z
Item Desc
78 OHM TWINAX
78 OHM TWINAX
78 OHM TWINAX
78 OHM TWINAX
78 OHM TWINAX
78 OHM TWINAX
78 OHM TWINAX
78 OHM TWINAX
78 OHM TWINAX
78 OHM TWINAX
78 OHM TWINAX
78 OHM TWINAX
00 OHM TWINAX
78 OHM TWINAX
Notes:
C = CRATE REEL PUT-UP.
Z = FINAL PUT-UP LENGTH MAY VARY (+ OR -) 10% FOR SPOOLS OR REELS AND(+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN.
Revision Number: 1 Revision Date: 03-07-2008
© 2010 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3 01-27-2010