Power Injectors for Diagnostic Imaging

Power Injectors
for Diagnostic Imaging
Contrast under Control
A resource for all your contrast
delivery needs
Contrast under Control
Mallinckrodt provides contrast delivery systems for
Computed Tomography (CT), Magnetic Resonance
Imaging (MRI) and Angiography. Our range of
1
injectors has been developed from a heritage of
innovation and technology.
2
3
Providing valuable assistance to contrast delivery,
each injector features integrated technological
advancements, all designed to enhance ease of
set up, operation and procedural time efficiencies.
1 Computed Tomography
2 Magnetic Resonance Tomography
3 Angiography
1
Optivantage™ DH
Dual Head Contrast Delivery System in CT
The advanced dual head CT injector
Dual Head Versatility
Performs up to 6 phases of contrast, saline
or Simultaneous.
Faceplates for both pre-filled and empty syringes.
Fully Programmable Powerhead
Enables you to select and amend protocols
whilst remaining at the patients side.
Intuitive user interface.
Step by step set up to help prevent air embolism.
Patency Check™ Feature
The Patency Check™ feature allows the operator
to inject saline at the maximum protocol flow rate to
confirm a patent fluid pathway to the patient prior to
contrast injection. This is carried out at the patients
side for better control.
Timing Bolus™ Feature
Perform a Timing Bolus™ injection of contrast
medium followed by a saline flush to determine ideal
scan delay for optimum image quality.
Tilt Enable
An injection cannot be started until the correct
enabling sequence has been completed, including
purging air and tilting the powerhead downward to
avoid injection of air bubbles.
Simultaneous Injection (optional)
Delivery of dual injection of contrast media
and saline.
Optibolus™ Software (optional)
Optibolus™ Bolus Shaping Software automatically
optimises your injection protocol for dynamic
scanning procedures.
Consistently provides uniform contrast enhancement
and can support improved image quality.1
2
Mounting Options
The Optivantage™ DH is
available in pedestal or ceiling
mounted configurations.
Manual Flow Knob
Calibrated for easy quarterturn priming, and colour
coded for saline and contrast.
Display Orientation
With just the touch of a
powerhead key, the display
graphics flip 180°
to provide proper orientation
for easy reading.
Intuitive User Interface
Easy to use menu allows you
to quickly change protocols,
flow rates and injection
volumes.
Auto purge function.
Quick and efficient auto-fill
of empty syringes.
Homing sequence of rams
after injection.
Built-In Heater
Blanket
Faceplate options for both
pre-filled syringes and empty
syringes are quick and easy
to change.
Pre-filled syringe faceplate
has an integrated heater
blanket to maintain contrast
at ideal temperature in order
to reduce viscosity.
3
Optistar™ Elite
Dual Head Contrast Delivery System in MRI
Designed for enhancing examination
outcomes and confidence
Patency Check™ Feature
The Patency Check™ feature allows
the operator to inject saline at the
maximum protocol flow rate to confirm
a patent fluid pathway to the patient
prior to contrast injection. This is
carried out at the patients side.
Multiple Phase Programming
As many as four phases can be
programmed for each injection
protocol.
As many as 40 injection protocols can
be stored in memory.
Timing Bolus™ Feature
Perform a Timing Bolus™ injection of
contrast medium followed by a saline
flush to determine ideal scan delay for
optimum image quality.
This feature allows the operator
to inject a specified amount of
contrast medium during a test scan
to determine optimum transit time of
the contrast medium to the region of
interest thus helping to maximise the
diagnostic information.
Enable from console
The injector can be enabled from
either the control room at the remote
console, or from the powerhead, which
may increase the efficiency.
4
Battery Free Operation
The first AC powered injector for the
MR suite. Eliminates time and cost
associated with battery charging and
replacement.
3T compatible/non-ferrous
dual powerhead
The powerhead, power control unit,
and remote stand are designed for
use in the MR suite.
Powerhead Keys
Large keys on the powerhead
ensure ease of use.
The injector can be enabled,
started and stopped directly
from the powerhead.
Check For Air Feature
System will not enable until
steps have been followed and
the operator has confirmed
that they have ‘checked for air’.
Auto retract
Rams are positioned to allow
the insertion of full syringes
by activating the auto retract
function.
Easy Drop-In Syringe
Loading
Results in faster procedures.
Syringe filling can be
performed in either the
control room or the scan
room.
Powerhead is designed to
accept empty syringes or
pre-filled syringes.
Variable Drip Mode
Switch between injection and
drip mode at any time, to
help ensure IV line patency
throughout the procedure.
Adjustable flowrate, volume
and interval. Display shows
remaining time and volume
available for drip mode.
5
CT 9000™ ADV
Single Head Contrast Delivery System in CT
Simplicity – for single head delivery
Touchscreen
Technical specifications
New easy to read colour touchscreen.
Flow Rate
Requires only 3 simple key strokes
to activate injection.
0.1 to 9.9 ml/sec
Programme up to four phases with
inject or scan delay features.
300 psi
Protocol manager to store and recall
up to 12 user defined protocols.
200 ml empty syringes
The system accommodates front
loading 200 ml disposable syringes
or pre-filled syringes.
Syringe Heater (optional)
37° C nominal.
Volume
Number of Phases
The powerhead LED display provides
a highly visible indication of
remaining volume.
The programmable Auto-Fill feature
automatically moves the syringe to
the selected volume.
4
Protocol Memory
12 protocols
OptiBolusTM software was designed to employ
multiphasic injection, to expand the window of
enhancement for contrast procedures.
OptiBolusTM software optimizes the contrast
media injection process through:
Bolus Shaping Software
Normal Injection
ENHANCEMENT LEVEL (HU)
50/75/100/125 ml high
1 ml to volume in syringe
Powerhead
OptiBolus Injection
Optimal
Enhancement
Level
TIME (s)
1. Bae KT, Tran HQ, Heiken JP. Uniform vascular contrast
enhancement and reduced contrast medium volume
achieved by using exponentially decelerated contrast
material injection method. Radiology. 2004;231:732–736.
6
Syringe Sizes
pressure prefilled syringes
Syringes
OptiBolus™
Pressure Limit
Uniform Distribution
Deliver contrast media at a controlled flow rate and volume,
to help ensure uniform vascular enhancement of the
pulmonary arterial system throughout the scan. This helps
decrease the possibility of missing the bolus.
Optimize the Utility of Contrast Volume
Potentially reduce IV contrast agent volume. This can
allow you to use contrast media more efficiently, while also
improving visualization at the bolus peak.1
Ease of Use
Your existing protocol converts to an OptiBolusTM protocol
at the touch of a button.
Order Information:
Optional OptiBolus Activation Key: # 844210
Angiomat™ Illumena™
Contrast Delivery System for Cardiology, Angiography and CT
Reliable and functional performance
Digital Powerhead Display
The LED display automatically
“flips” as the powerhead is rotated
– ensuring proper orientation for
viewing.
Indicates programmed protocol and
volume remaining in the syringe.
Fill Control Bar
Allows easy, one finger operation.
Variable speed control of ram for
syringe filling, pull-back, or infusion.
Syringes
The latex free and transparent
syringes provide a crystal clear view
of the contrast medium.
Compatible with pre-filled syringes.
Air Detection Device
The optional Air Detection and
Warning System (ADAWS) detects
empty syringes and air bolus.
Touchscreen
The pressure sensitive touchscreen
display makes the injection setup
direct and easy.
Protocol manager to store and recall
user‑defined protocols.
Multimodality
With just a touch of a button the
injector switches between Angio and
CT modes.
7
Optivantage™ DH
Product Information
Technical Specifications
Delivery System
Code
Flow Rate
0.1 – 10.0 ml/sec
Pressure Limit
50 – 325 peak psi
Syringe Sizes
200 ml empty syringes
50, 75, 100, 125 ml
high pressure
prefilled syringes
Syringe Heater
37°C nominal
Minimises the loss of heat
from preheated contrast
Volume
1 mL to volume in syringe
Up to 200 ml
Description
Pedestal
V8401
Optivantage™ – Dual Head CT Contrast Delivery System
V8411
Optivantage™ – Dual Head CT Contrast Delivery System with OEM interface
V8431
Optivantage™ – Dual Head CT Contrast Delivery System with Simultaneous Injection
and OEM interface
Ceiling Mount
V8402
Optivantage™ – Dual Head CT Contrast Delivery System
V8412
Optivantage™ – Dual Head CT Contrast Delivery System with OEM interface
V8432
Optivantage™ – Dual Head CT Contrast Delivery System with Simultaneous Injection
and OEM interface
Disposables
Code
Description
QTY
844021
Multipack
Scan Delay
0 – 600 sec
Inject Delay
0 – 600 sec
844021
Syringe - Multipack 200 ml (Dual Check Valve Y Tubing)
50 each
844020
Syringe - Multipack 200 ml (No Check Valve Y Tubing)
50 each
844015
Syringe - Multipack 200 ml (Dual Check Valve Y Tubing)
50 each
Phase Delay
0 – 600 sec
800099
CT9000™ ADV - Multipack 200 ml (Coiled tubing)
50 each
Number of Phases
6
844023
Syringes - Dualpack 200 ml (Dual Check Valve)
20 each
844022
Syringes - Dualpack 200 ml (No Check Valve)
20 each
844016
Syringe - Dualpack 200 ml (Dual Check Valve Y Tubing)
20 each
Protocol Memory
40
Inject Results
Last 24 injected protocols
SI contrast % ratio
10% to 90% in 5% steps
844023
Dual Pack
Syringe and J-Straw only
800096
CT9000™ ADV - Front load Syringe with Handi-Fil™
800096
810555
50 each
Y-connection tubing
844012
CT Y Tubing Dual Check Valves - 152 cm (60”)
50 each
844011
CT Y Tubing Single Check Valve - 152 cm (60”)
50 each
844010
CT Y Tubing No Check Valve - 152 cm (60”)
50 each
Y-connector only
810555
Extension Y Tubing Adapter - Dual Check Valves
601195
810551
50 each
Extension tubing
601195
Coiled Extension Tubing - 152 cm (60”)
50 each
CTL150N
Straight Extension Tubing 150 cm (60”)
50 each
CTF015N
Transfer Set
810551
Transfer Set
50 each
CTF015N
Automatic filling Tubing with Dripping Chamber
50 each
Product availability and Summary of Product Characteristics may differ from one country to another.
For your country’s specific information, please contact your local Mallinckrodt Office or Representative.
Mallinckrodt, the “M” brand mark and the Mallinckrodt Pharmaceuticals logo are
trademarks of a Mallinckrodt company. © 2013 Mallinckrodt. All rights reserved.
Optistar™ ELITE
Product Information
Technical Specifications
Delivery System
Flow Rate
0.1 to 10 ml/sec
Code
Pressure Limit
60 ml syringe: 150 psi
10, 15, 20, 30 ml PFS: 200 psi
M5200
Syringe Sizes
60 ml empty syringes
10, 15, 20, 30 ml PFS
Volume
A Side: Up to 60 ml
10, 15, 20, 30 ml PFS
B Side: Up to 60 ml
Scan Delay
0 – 60 sec
Inject Delay
0 – 300 sec
Number of Phases
6
Phase Delay
0 – 600 sec
Protocol Memory
40
Description
Pedestal
Optistar™ ELITE– MR Contrast Delivery System - Rolling Stand
Disposables
Code
Description
QTY
Optistar™ MR Syringe 60/60/90
Multipack
50 each
Multipack
801800
801800
Syringe with Spike
801801
Optistar™ MR Syringe Lateral Flow
Needle 60 ml
50 each
Y - Connection Tubing
801106
Y - Tubing - Single Check Valve
152 cm (60”)
100 each
801107
Y - Tubing - Single Check Valve
229 cm (90”)
100 each
801801
Y - Connection only
810555
Extension Y Tubing Adapter Dual Check Valves
50 each
801107
Extension tubing
601195
Coiled Extension Tubing - 152 cm (60”)
50 each
Inject Result
Last 48 injected protocols
MR Compatibility
Up to 3 Tesla Scanner
Power supply
AC Powered. No battery
Product availability and Summary of Product Characteristics may differ from one country to another.
For your country’s specific information, please contact your local Mallinckrodt Office or Representative.
Mallinckrodt, the “M” brand mark and the Mallinckrodt Pharmaceuticals logo are
trademarks of a Mallinckrodt company. © 2013 Mallinckrodt. All rights reserved.
Angiomat™ Illumena™
Product Information
Technical Specifications
Flow Rate
Angio Mode: 0.1 – 40.0 ml/s
CT Mode: 0.1 – 10.0 ml/s
Pressure Limit
Angio Mode: 75 – 1200 psi
CT Mode: 75 – 300 psi
Syringe Sizes
150, 200 ml - empty syringes
50, 75, 100, 125 ml - PFS
Syringe Heater
37°C nominal.
Minimises the loss of heat
from preheated contrast
Inject Delay
0 – 300 sec
X–ray Delay
0 – 300 sec
Scan Delay (CT–Mode)
0 –300 sec
Delivery System
Code
Description
Pedestal
7261
Illumena™ – Contrast Delivery System with Rolling Pedestal
7261-S
Illumena™ – Contrast Delivery System with Rolling Pedestal
- Siemens Interface
Ceiling Mount
7272
Illumena™ – Contrast Delivery System with Ceiling Suspension and Rack Mount
7272-S
Illumena™ – Contrast Delivery System Fixed Ceiling Suspension - Siemens Interface
Table Mount
7267
Illumena™ – Contrast Delivery System with Table Mount
7267-S
Illumena™ – Contrast Delivery System Fixed Table Mount Rack- Siemens Interface
Faceplate (Optional)
900491
900480
Illumena™ – Faceplate Assembly - 125 ml (PFS)
900491
Illumena™ – Faceplate Assembly with Air Detection System - 150 ml
900477
Illumena™ – Faceplate Assembly - 200 ml
Heater Blanket (Optional)
900430
Illumena™ – Heater Blanket Assembly
Rate Rise
0 – 10 sec
Phase Delay
0 – 300 sec
Number of Phases
1, 2 or 3–4
Protocol Memory
Angio Modes: 45 protocols
CT modes: 45 protocols
Disposables
Code
Description
QTY
Syringe and J-straw
900101
Syringe with handifil - quick connector 150 ml
50 each
900102
Syringe with handifil - quick connector 150 ml with
Coiled Extension Tubing - 152 cm (60”)
50 each
900103
Linden Luer Syringe with Handi-Fill™
Straw 150 ml
50 each
900104
Linden Luer Syringe with Handi-Fill™ Straw
150 ml with Coiled Extension Tubing - 152 cm (60”)
50 each
900105
Syringe with Handi-Fill™ Straw - 200 ml
50 each
900103
FLEX75RAN
HP120RAN
Extension Tubing
FLEX120N
FLEX120RAN
High Pressure Connection Line 120 cm
High Pressure Connection Line with Rotating
Adaptor 120 cm
25 each
25 each
FLEX75RAN
High Pressure Connection Line with Rotating
Adaptor 75 cm
25 each
HP120RAN
Flexible high pressure tube with rotating
Adapter 120 cm
25 each
Optional interfaces available. For referencies please contact your local Mallinckrodt Office or Representative.
Mallinckrodt, the “M” brand mark and the Mallinckrodt Pharmaceuticals logo are
trademarks of a Mallinckrodt company. © 2013 Mallinckrodt. All rights reserved.
Product availability and Summary of Product Characteristics may differ from one country to another.
For your country’s specific information, please contact your local Mallinckrodt Office or Representative.
For further information, please contact your local representative or
UK Marketing for further information.
Tel No: +44 1329 224159
Fax No: +44 1329 224324
Mallinckrodt, the “M” brand mark and the Mallinckrodt Pharmaceuticals logo are trademarks of a
Mallinckrodt company. ©2013 Mallinckrodt. All rights reserved. CM-POWERINJ/INT • 11/2013
MALLINCKRODT PHARMACEUTICALS UK COMMERCIAL LTD
4500 Parkway, Whiteley, Fareham, Hampshire PO15 7NY