iES28GF-L2
www.iS5com.com
Intelligent 28 Port Configurable Gigabit Switch IEC 61850, IEEE 1613 and EN50155
Features
ââ
Supports iRing (recovery time < 20ms up to 250 units in one ring)
ââ
Supports STP, RSTP and MSTP
ââ
Supports Layer 3 routing, RIP and static routing function
ââ
Support IEEE 1588v2 PTP clock synchronization
ââ
IPv6 support
ââ
VLAN Priority: Supports priority-tagged frames to be received
by specific IEDs
ââ
Supports HTTPS/SSH protocol enhanced network security
ââ
Supports SMTP clock client
ââ
IP-based bandwidth management
ââ
Application-based QoS management
ââ
Device Linking security function
ââ
DOS/DDOS auto threat prevention
ââ
IGMP v2/v3 (IGMP snooping support)
ââ
SNMP v1/v2c/v3 & RMON and 802.1Q VLAN Network Management
ââ
Support ACL, TACACS+ and 802.1x User Authentication
ââ
Supports 9.6K Bytes Jumbo Frame
ââ
Multiple alarm notification methods
ââ
iManage Software Suite (iMSS) supports centralized management and
configurable by Web-based, Telnet, Console(CLI), Windows NT/2000/
XP/2003/VISTA/7
ââ
LLDP (Link Layer Discovery Protocol)
ââ
19 inch rack mountable
IEC 61850
iS5com.com
Tel: +905-670-0004
Fax: +289-401-5206
Email: info@is5com.com
#3-7490 Pacific Circle, Mississauga, Ontario, L5T 2A3
All specifications are subject to change without notice.
IS5 REV.06282016
Page—1
Introduction
iES28GF-L2 is a highly redundant and scalable Layer 2/3 managed Gigabit Ethernet switch with 4 modular slots. Designed to
withstand the harshest environments of Transmission and Distribution substations and rolling stock applications. The iES28GF-L2
is fully compliant with industry standards such as IEC 61850, IEEE 1613, and EN50155, with an operating temperature from
-40°C to +85°C and redundancy support through functions like iRing and STP/RSTP/MSTP assuring protection of all mission
critical network applications.
iES28GF-L2 can also be managed conveniently via the iManage Software Suite, Telnet, and console (CLI) configuration.
ââ IP-based Bandwidth Management: The switch provides advanced IP-based bandwidth management limiting maximum
bandwidth for each IP device. Users can configure an IP camera and NVR with dedicated bandwidth and limit the bandwidth of
other devices.
ââ Application-Based QoS: The switch also supports application-based QoS. Application-based QoS can be set with the highest
priority for data streaming according to TCP/UDP port number.
ââ Device Link Function: The special Device Link function permits only allowed IP addresses with a MAC address to access the
network preventing unauthorized access to the network .
ââ Advanced DOS/DDOS Auto Prevention: Switch provides advance DOS/DDOS auto prevention. – This is a hardware based
prevention. If there is a sudden surge in IP flow, the switch locks the source IP address temporarily and hence prevents network
failure.
ââ IEEE 1588 Precision Time Protocol: IEEE 1588 PTPv2 provides precision time synchronization for protection and control
applications such as SMV in the IEC 61850 process bus.
All specifications are subject to change without notice |
IS5 REV.005082017
www.iS5com.com | Page—2
Specifications
Model Number iES28GF-L2
Physical Ports
Slot 1 - (Ports 1-8)
8 X 10/100/1000Base-T(X) RJ45 Ports, 8 X 100/1000Base-X SFP Ports,
2 or 4 X 100Base-FX Fiber SC/ST Ports, 2 or 4 X 1000Base-SX/LX Fiber SC/ST Ports,
2 or 4 X 10Base-FL Ports
Slot 2 - (Ports 9-16)
8 X 10/100/1000Base-T(X) RJ45 Ports, 8 X 100/1000Base-X SFP Ports,
2 or 4 X 100Base-FX Fiber SC/ST Ports, 2 or 4 X 1000Base-SX/LX Fiber SC/ST Ports,
2 or 4 X 10Base-FL Ports
Slot 3 - (Ports 17-24)
8 X 10/100/1000Base-T(X) RJ45 Ports, 8 X 100/1000Base-X SFP Ports,
2 or 4 X 100Base-FX Fiber SC/ST Ports, 2 or 4 X 1000Base-SX/LX Fiber SC/ST Ports,
2 or 4 X 10Base-FL Ports
Slot 4 - (Ports 25-28)
4 X 1000Base-X SFP Ports,
2 or 4 X 1000Base-SX/LX Fiber SC/ST Ports
Fixed Module Slot 1-3 (Ports 1-16)
**Note: If this fixed module is selected,
select Module for Slot 4 only from above
16 X 10/100/1000Base-T(X) RJ45 and 100/1000Base-X SFP Combo Ports,
16 X 100Base-FX Fiber SC/ST Ports,
16 X 1000Base-SX/LX Fiber SC/ST Ports
Fixed Module Slot 2-4 (Ports 9-28)
**Note: If this fixed module is selected,
select Module for Slot 1 only from above
16 X 10/100/1000Base-T(X) RJ45 and 100/1000Base-X SFP Combo Ports,
16 X 100Base-FX Fiber SC/ST Ports,
16 X 1000Base-SX/LX Fiber SC/ST Ports
Technology
Ethernet Standards
IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-TX and 100Base-FX
IEEE 802.3ab for 1000Base-T
IEEE 802.z for 1000Base-X
IEEE 802.3x for Flow control
IEEE 802.3ad for LACP (Link Aggregation Control Protocol)
IEEE 802.1p for COS (Class of Service)
IEEE 802.1Q for VLAN Tagging
IEEE 802.1w for RSTP (Rapid Spanning Tree Protocol)
IEEE 802.1s for MSTP (Multiple Spanning Tree Protocol)
IEEE 802.1x for Authentication
IEEE 802.1AB for LLDP (Link Layer Discovery Protocol)
MAC Table
8k
Buffer Memory
4Mb
Switch Capacity
128Gbps
Priority Queues
8
Processing
Store-and-Forward
Switch Properties
Switching latency: 7 us
Max. Number of Available VLANs: 256
IGMP multicast groups: 128 for each VLAN
Port rate limiting: User Defined
Jumbo frame
Up to 9.6K Bytes
Security Features
Device Linking security feature.
Enable/disable ports, MAC based port security
Port based network access control (802.1x)
Single 802.1x and Multiple 802.1x
MAC-based authentication, QoS assignment
Guest VLAN, MAC address limit, TACACS+
VLAN (802.1Q) to segregate and secure network traffic
Radius centralized password management
SNMPv3 encrypted authentication and access security
Web and CLI authentication and authorization
Authorization (15 levels) via TACACS+
IP source guard
All specifications are subject to change without notice |
IS5 REV.005082017
www.iS5com.com | Page—3
Software Features
Hardware routing, RIP and static routing
IEEE 1588v2 PTP clock synchronization
IEEE 802.1D Bridge, auto MAC address learning/aging and MAC address (static)
Multiple VLAN Registration Protocol (MVRP), MSTP (RSTP/STP compatible)
Redundant Ring (iRing) with recovery time less than 20ms over 250 units
TOS/Diffserv supported, Quality of Service (802.1p) for real-time traffic
VLAN (802.1Q) with VLAN tagging and GVRP supported
Voice VLAN, IGMP v2/v3 Snooping
IP-based bandwidth management, Application-based QoS management
DOS/DDOS auto prevention, Port configuration, status, statistics, monitoring, security
DHCP Server/Client/snooping, DHCP Relay, Modbus TCP, DNS client proxy
ARP inspection, SMTP Client
Network Redundancy
iRing
iBridge
MSTP (RSTP/STP compatible)
RS-232 Serial Console Port
RS-232 in RJ-45 connector with console cable. 115200bps, 8, N, 1
Fault Contact
Relay
Relay output capacity of 1A at 24VDC
Power
Input Power
Redundant Power Supplies: Dual DC Inputs 9-36VDC, Dual DC Inputs 36-72VDC,
or Dual Input 88-370VDC or 85-264VAC
Overload Current Protection
Present
Physical Characteristics
Enclosure
IP-40 Galvanized Steel
Dimension (W x D x H)
446.6 (W) x 360 (D) x 44.3 (H) mm (17.58 x 14.17 x 1.74 inches)
Weight (g)
~8000 g
Environmental
Storage Temperature
-40°C to +85°C (-40°F to +185°F)
Operating Temperature
-40°C to +85°C (-40°F to +185°F) No Fans
Operating Humidity
5% to 95% Non-condensing
Regulatory Approvals
Power Automation
IEC 61850-3, IEEE 1613 Compliant
EMI
FCC Part 15, CISPR (EN55022) class A,
EN50155 (EN50121-3-2, EN55011, EN50121-4)
EMS
EN61000-4-2 (ESD), EN61000-4-3 (RS),
EN61000-4-4 (EFT),EN61000-4-5 (Surge),
EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11
Warranty
Warranty
5 Years
All specifications are subject to change without notice |
IS5 REV.005082017
www.iS5com.com | Page—4
Dimensions
All Dimensions are in Inches
Ordering Information
Base
Power
Supply
1
Power
Supply
2
†Fixed Module
Mount Slot 1-3
(Ports 1-16)
†Fixed Module
Slot 1
Slot 2-4
(Ports 1-8)
(Ports 9-28)
Slot 2
Slot 3
(Ports 9-16) (Ports 17-24)
Slot 4
(Ports 25-28)
iES28GF-L2
HV
LV
RR
XX
XX
8GRJ45
XX
8GSFP
4GMMST
iES28GF-L2
|
|
|
|
|
|
|
|
|
Core assembly
and packaging
XX
XX
|
|
|
|
|
|
|
None
LV
LV
|
|
|
|
|
|
|
24VDC (936VDC)
MV
MV
|
|
|
|
|
|
|
48 VDC (3672VDC)
HV
HV
|
|
|
|
|
|
|
88-370VDC or
85-264VAC
|
Rack Mount
Power
Terminals in the
Front/Display
Rear
RF
|
|
|
|
|
Description
RR
|
|
|
|
|
|
Rack Mount
Power
Terminals in the
Rear/Display
Front
P
|
|
|
|
|
|
Panel Mounting
N
|
|
|
|
|
|
No Mounting
Hardware
All specifications are subject to change without notice |
IS5 REV.005082017
www.iS5com.com | Page—5
Select Port Configuration for Slots 1 to 3
Select Port Configuration for Slot 4
iS5Com #
Slot 1 (Ports 1-8), Slot 2 (Ports 9-16), Slot 3 (Ports 17-24) Description Options
iS5Com #
Slot 4 (Ports 25-28) Description Options
XX
None
XX
None
8GRJ45
8 x 10/100/1000Base-T(X) RJ45
2GSFP
2 x 1000Base-X SFP (Blank no optical transceivers**)
2MMSTFL
2 x 10Base-FL Multimode ST
4GSFP
4 x 1000Base-X SFP (Blank no optical transceivers**)
4MMSTFL
4 x 10Base-FL Multimode ST
2GMMSC
2 x 1000SX Multimode SC, 550m, 850nm
8GSFP
8 x 100/1000Base-X SFP (Blank no optical transceivers**)
4GMMSC
4 x 1000SX Multimode SC, 550m, 850nm
2MMSC2
2 x 100FX Multimode SC, 2km, 1310nm
2GMMST
2 x 1000SX Multimode ST, 550m, 850nm
4MMSC2
4 x 100FX Multimode SC, 2km, 1310nm
4GMMST
4 x 1000SX Multimode ST, 550m, 850nm
2MMST2
2 x 100FX Multimode ST, 2km, 1310nm
2GSMSC10
2 x 1000LX Singlemode SC, 10km, 1310nm
4MMST2
4 x 100FX Multimode ST, 2km, 1310nm
4GSMSC10
4 x 1000LX Singlemode SC, 10km, 1310nm
2SMSC15
2 x 100FX Singlemode SC, 15km, 1310nm
2GSMST10
2 x 1000LX Singlemode ST, 10km, 1310nm
4SMSC15
4 x 100FX Singlemode SC, 15km, 1310nm
4GSMST10
4 x 1000LX Singlemode ST, 10km, 1310nm
2SMST15
2 x 100FX Singlemode ST, 15km, 1310nm
2GSMSC40
2 x 1000LX Singlemode SC, 40km, 1310nm
4SMST15
4 x 100FX Singlemode ST, 15km, 1310nm
4GSMSC40
4 x 1000LX Singlemode SC, 40km, 1310nm
2SMSC40
2 x 100FX Singlemode SC, 40km, 1310nm
2GSMST40
2 x 1000LX Singlemode ST, 40km, 1310nm
4SMSC40
4 x 100FX Singlemode SC, 40km, 1310nm
4GSMST40
4 x 1000LX Singlemode ST, 40km, 1310nm
2SMST40
2 x 100FX Singlemode ST, 40km, 1310nm
2GSMSC70
2 x 1000LX Singlemode SC, 70km, 1550nm
4SMST40
4 x 100FX Singlemode ST, 40km, 1310nm
4GSMSC70
4 x 1000LX Singlemode SC, 70km, 1550nm
2SMSC60
2 x 100FX Singlemode SC, 60km, 1310nm
2GSMST70
2 x 1000LX Singlemode ST, 70km, 1550nm
4SMSC60
4 x 100FX Singlemode SC, 60km, 1310nm
4GSMST70
4 x 1000LX Singlemode ST, 70km, 1550nm
2SMST60
2 x 100FX Singlemode ST, 60km, 1310nm
4SMST60
4 x 100FX Singlemode ST, 60km, 1310nm
2SMSC80
2 x 100FX Singlemode SC, 80km, 1550nm
iS5Com #
†Fixed Module Slot 2-4 (Ports 9-28) Description Options
4SMSC80
4 x 100FX Singlemode SC, 80km, 1550nm
XX
None
2SMST80
2 x 100FX Singlemode ST, 80km, 1550nm
16GCX
Combo*** 16 x 10/100/1000Base-T(X) RJ45 and 100/1000Base-X SFP
(Blank no optical transceivers**)
4SMST80
4 x 100FX Singlemode ST, 80km, 1550nm
16MMSC2
16 x 100FX Multimode SC, 2km, 1310nm
2SMSC100
2 x 100FX Singlemode SC, 100km, 1550nm
16MMST2
16 x 100FX Multimode ST, 2km, 1310nm
4SMSC100
4 x 100FX Singlemode SC, 100km, 1550nm
16SMSC15
16 x 100FX Singlemode SC, 15km, 1310nm
2SMST100
2 x 100FX Singlemode ST, 100km, 1550nm
16SMST15
16 x 100FX Singlemode ST, 15km, 1310nm
4SMST100
4 x 100FX Singlemode ST, 100km, 1550nm
16SMSC40
16 x 100FX Singlemode SC, 40km, 1310nm
16SMST40
16 x 100FX Singlemode ST, 40km, 1310nm
16SMSC60
16 x 100FX Singlemode SC, 60km, 1310nm
16SMST60
16 x 100FX Singlemode ST, 60km, 1310nm
16SMSC80
16 x 100FX Singlemode SC, 80km, 1550nm
16SMST80
16 x 100FX Singlemode ST, 80km, 1550nm
Fixed Module Configuration for Slots 2 to 4
Fixed Module Configuration for Slots 1 to 3
iS5Com #
†Fixed Module Slot 1-3 (Ports 1-16) Description Options
XX
None
16GCX
Combo*** 16 x 10/100/1000Base-T(X) RJ45 and 100/1000Base-X SFP
(Blank no optical transceivers**)
16MMSC2
16 x 100FX Multimode SC, 2km, 1310nm
16SMSC100
16 x 100FX Singlemode SC, 100km, 1550nm
16MMST2
16 x 100FX Multimode ST, 2km, 1310nm
16SMST100
16 x 100FX Singlemode ST, 100km, 1550nm
16SMSC15
16 x 100FX Singlemode SC, 15km, 1310nm
16GMMSC
16 x 1000SX Multimode SC, 550m, 850nm
16SMST15
16 x 100FX Singlemode ST, 15km, 1310nm
16GMMST
16 x 1000SX Multimode ST, 550m, 850nm
16SMSC40
16 x 100FX Singlemode SC, 40km, 1310nm
16GSMSC10
16 x 1000LX Singlemode SC, 10km, 1310nm
16SMST40
16 x 100FX Singlemode ST, 40km, 1310nm
16GSMST10
16 x 1000LX Singlemode ST, 10km, 1310nm
16 x 100FX Singlemode SC, 60km, 1310nm
16GSMSC40
16 x 1000LX Singlemode SC, 40km, 1310nm
16 x 100FX Singlemode ST, 60km, 1310nm
16GSMST40
16 x 1000LX Singlemode ST, 40km, 1310nm
16 x 100FX Singlemode SC, 80km, 1550nm
16GSMSC70
16 x 1000LX Singlemode SC, 70km, 1550nm
16SMST80
16 x 100FX Singlemode ST, 80km, 1550nm
16GSMST70
16 x 1000LX Singlemode ST, 70km, 1550nm
16SMSC100
16 x 100FX Singlemode SC, 100km, 1550nm
16SMST100
16 x 100FX Singlemode ST, 100km, 1550nm
16GMMSC
16 x 1000SX Multimode SC, 550m, 850nm
16GMMST
16 x 1000SX Multimode ST, 550m, 850nm
16GSMSC10
16 x 1000LX Singlemode SC, 10km, 1310nm
16GSMST10
16 x 1000LX Singlemode ST, 10km, 1310nm
16GSMSC40
16 x 1000LX Singlemode SC, 40km, 1310nm
16GSMST40
16 x 1000LX Singlemode ST, 40km, 1310nm
16GSMSC70
16 x 1000LX Singlemode SC, 70km, 1550nm
16GSMST70
16 x 1000LX Singlemode ST, 70km, 1550nm
16SMSC60
16SMST60
16SMSC80
All specifications are subject to change without notice |
†Fixed Module Slot 1-3 (Ports 1-16) - If Fixed Module Slots 1 to 3 is selected,
Select Module for Slot 4 only.
†Fixed Module Slot 2-4 (Ports 9-28) - If Fixed Module Slot 4 is selected,
Select Module for Slot 1 only.
Example Order Code: iES28GF-L2-HV-LV-RR-XX-XX-8GRJ45-XX-8GSFP-4GMMST-C1-F3.07
Description: 28 Port Gigabit Switch, (Power Supply 1) Input 88-370VDC or 85-264VAC,
(Power Supply 2) Input 24VDC (9-36VDC), Rack Mount Power Terminals in the Rear/
Display Front, Fixed Module Slot 1-3 (Ports 1-16) None, Fixed Module Slot 2-4
(Ports 9-28) None, 8 x 10/100/1000Base-T(X) RJ45 Ports, Slot 2 (Ports 9-16) None,
8 x 100/1000Base-X SFP Ports, 4 x 1000Base-SX Multimode ST, 550m,
850nm Ports, Conformal Coating, Firmware version 3.07
C1 – Add for conformal coating
FW – Leave blank for latest firmware
NOTE: When selecting 2GSFP, 4GSFP, or 8GSFP (Blank no optical transceivers**)
**SFP’s to be ordered separately.
IS5 REV.005082017
www.iS5com.com | Page—6
**SFP’s to be ordered separately.
SFP Module #
Description
SFP100-MM-05
SFP 100Mbps Multimode LC Transceiver 550m, 850nm, -40°C to +85°C
SFP100-MM-2
SFP 100Mbps Multimode LC Transceiver 2km, 1310nm, -40°C to +85°C
SFP100-SM-10
SFP 100Mbps Singlemode LC Transceiver 10km, 1310nm, -40°C to +85°C
SFP100-SM-30
SFP 100Mbps Singlemode LC Transceiver 30km, 1310nm, -40°C to +85°C
SFP100-SM-60
SFP 100Mbps Singlemode LC Transceiver 60km, 1310nm, -40°C to +85°C
SFP100-SM-100
SFP 100Mbps Singlemode LC Transceiver 100km, 1550nm, -40°C to +85°C
SFP100-SM-120
SFP 100Mbps Singlemode LC Transceiver 120km, 1550nm, -40°C to +85°C
SFP100BIDI1-SM-20
SFP 100Mbps Bi-Directional Singlemode LC Transceiver 20km, TX1310nm, RX1550nm, -40°C to +85°C
SFP100BIDI2-SM-20
SFP 100Mbps Bi-Directional Singlemode LC Transceiver 20km, TX1550nm, RX1310nm, -40°C to +85°C
SFP100BIDI1-SM-40
SFP 100Mbps Bi-Directional Singlemode LC Transceiver 40km, TX1310nm, RX1550nm, -40°C to +85°C
SFP100BIDI2-SM-40
SFP 100Mbps Bi-Directional Singlemode LC Transceiver 40km, TX1550nm, RX1310nm, -40°C to +85°C
SFP100BIDI1-SM-60
SFP 100Mbps Bi-Directional Singlemode LC Transceiver 60km, TX1310nm, RX1550nm, -40°C to +85°C
SFP100BIDI2-SM-60
SFP 100Mbps Bi-Directional Singlemode LC Transceiver 60km, TX1550nm, RX1310nm, -40°C to +85°C
SFP1000-TX
SFP 10/100/1000Mbps TX RJ45 Transceiver 100m, -40°C to +85°C
SFP1000-MM-05
SFP 1Gbps Multimode LC Transceiver 550m, 850nm, -40°C to +85°C
SFP1000-MM-2
SFP 1Gbps Multimode LC Transceiver 2km, 1310nm, -40°C to +85°C
SFP1000-SM-10
SFP 1Gbps Singlemode LC Transceiver 10km, 1310nm, -40°C to +85°C
SFP1000-SM-20
SFP 1Gbps Singlemode LC Transceiver 20km, 1310nm, -40°C to +85°C
SFP1000-SM-30
SFP 1Gbps Singlemode LC Transceiver 30km, 1310nm, -40°C to +85°C
SFP1000-SM-40
SFP 1Gbps Singlemode LC Transceiver 40km, 1310nm, -40°C to +85°C
SFP1000-SM-50
SFP 1Gbps Singlemode LC Transceiver 50km, 1550nm, -40°C to +85°C
SFP1000-SM-70
SFP 1Gbps Singlemode LC Transceiver 70km, 1550nm, -40°C to +85°C
SFP1000-SM-80
SFP 1Gbps Singlemode LC Transceiver 80km, 1550nm, -40°C to +85°C
SFP1000BIDI1-SM-10
SFP 1Gbps Bi-Directional Singlemode LC Transceiver 10km, TX1310nm, RX1550nm, -40°C to +85°C
SFP1000BID2-SM-10
SFP 1Gbps Bi-Directional Singlemode LC Transceiver 10km, TX1550nm, RX1310nm, -40°C to +85°C
SFP1000BIDI1-SM-20
SFP 1Gbps Bi-Directional Singlemode LC Transceiver 20km, TX1310nm, RX1550nm, -40°C to +85°C
SFP1000BID2-SM-20
SFP 1Gbps Bi-Directional Singlemode LC Transceiver 20km, TX1550nm, RX1310nm, -40°C to +85°C
SFP1000BIDI1-SM-40
SFP 1Gbps Bi-Directional Singlemode LC Transceiver 40km, TX1310nm, RX1550nm, -40°C to +85°C
SFP1000BID2-SM-40
SFP 1Gbps Bi-Directional Singlemode LC Transceiver 40km, TX1550nm, RX1310nm, -40°C to +85°C
SFP1000BIDI1-SM-60
SFP 1Gbps Bi-Directional Singlemode LC Transceiver 60km, TX1310nm, RX1550nm, -40°C to +85°C
SFP1000BID2-SM-60
SFP 1Gbps Bi-Directional Singlemode LC Transceiver 60km, TX1550nm, RX1310nm, -40°C to +85°C
SFP1000BIDI1-SM-80
SFP 1Gbps Bi-Directional Singlemode LC Transceiver 80km, TX1310nm, RX1550nm, -40°C to +85°C
SFP1000BID2-SM-80
SFP 1Gbps Bi-Directional Singlemode LC Transceiver 80km, TX1550nm, RX1310nm, -40°C to +85°C
All specifications are subject to change without notice |
IS5 REV.005082017
www.iS5com.com | Page—7
Download PDF
Similar pages