Tripp Lite PDU3VSR10L2120 power distribution unit PDU Datasheet

Add to my manuals
4 Pages

advertisement

Tripp Lite PDU3VSR10L2120 power distribution unit PDU Datasheet | Manualzz

Tripp Lite

1111 West 35th Street

Chicago, IL 60609 USA

Telephone: +(773) 869 1234

E-mail: [email protected]

Model #: PDU3VSR10L2120

3-Phase Switched PDU, 5.7 kW, 24 208V outlets (21-C13, 3-C19) 10-ft. Cord, NEMA L21-20P 20A input connection

Highlights

Switched 5.7kW 3 Phase 208V PDU; 70 in. / 178cm 0U vertical rackmount

Reports voltage, frequency & load per-outlet or phase via ethernet interface

Visual current meter; Toolless button-mount installation

NEMA L21-20P 20A (3P+N+E) 208V 3 phase input; 10 ft. / 3m line cord

21 C13 & 3 C19 single phase switched outlets with cord retention brackets

Temperature, humidity and contact closure monitoring options

Description

Tripp Lite 3 phase Switched PDU / Power Distribution Unit offers advanced network control and monitoring with the ability to turn on, turn off, recycle or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption per-phase or per-receptacle. PowerAlert interface supports remote control and custom notification of user-specified conditions via email, secure web, SNMP,

Telnet or SSH interface. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware, or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware. PDU output current consumption in amps per-phase or per-receptacle can be displayed locally via visual meter or remotely via web/network interface to warn of potential overloads before critical IT mains or branch breakers trip.

Applications

Ideal for 3 phase network configurations in datacenters and heavily configured equipment racks

Package Includes

Switched rackmount PDU with pre-installed mounting buttons

Cord retention brackets

Rack mounting brackets

Owner's manual

Features

5.7kW 3 phase 208V Switched Power Distribution Unit / PDU with built-in web/network interface

Attached NEMA L21-20P 20A (3P+N+E) 208V 3 phase input; 10 ft. / 3m cord

0U, 70 inch / 178cm vertical form factor

24 switched 208V outlets (21 C13, 3 C19) in 3 single phase load banks

Supports power-on, power-off or reboot of each outlet on a real-time or programmable basis

Enables reboot of locked equipment, custom power-on/power-off sequences, load-shedding of optional loads and disabling unused outlets

Network interface provides PDU control and data regarding input voltage, per-outlet and per-phase load levels

Digital display with scroll-buttons supports per-outlet or per-phase load levels, IP-address self-identification and 180 degree display rotation

Supports user-specified alarm notification thresholds

In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors

DHCP/Manual configuration support

10/100 Mbps auto-sensing

Real-time clock backup maintains the time of day and date even if the PDU is unpowered

Real-time clock backup maintains the time of day and date even if the PDU is unpowered

Tiered access privileges allow an administrator and a guest to login via web browser

Alert notifications via email or SNMP traps offer immediate event notification

Firmware upgrade ability supports future product enhancements

Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols

Fully compatible with FREE PowerAlert Network Management System / NMS Software

Included cord retention brackets

Toolless mounting in button-mount compatible racks

Nut-and-bolt mounting support for other racks

Specifications

OVERVIEW

Model Type

PDU Type

OUTPUT

Output Capacity Details

Frequency compatibility

Output nominal voltage

Outlet quantity / type

Switched

Switched

5.7kVA total; 9.2A per bank (balanced)

60 Hz

208V single phase

24 total - 21 C13 (7 per phase), 3 C19 (1 per phase)

Each outlet is individually controllable via remote interface Customized load management receptacles

INPUT

PDU Input Voltage

Recommended Electrical

Service

208

208V 3 phase

Maximum Input Amps (A) 16

Input connection type NEMA L21-20P 20A (3P+N+E)

Plug Type

PDU Plug Type

NEMA L21-20P 20A (3P+N+E)

NEMA L21-20P

Input cord length (ft.)

Voltage compatibility

(VAC)

10

3-Phase; 208

Phase

LEDS ALARMS & SWITCHES

3-Phase

Switches Pushbutton scroll switch enables local power consumption display of each phase or outlet separately, display rotate and display IP address functions

2 digit current meter display reports output amps per phase and IP address self identification Front panel LEDs

PHYSICAL

Shipping weight (lbs) 20.45

Shipping weight (kg) 9.3

Unit Dimensions (HWD/in) 70 x 2.19 x 3.26

Unit Dimensions

(HWD/cm)

Shipping Dimensions

(HWD/in)

Shipping Dimensions

(HWD/cm)

Unit weight (lbs)

Unit weight (kg)

Material of construction

Style

Form factors supported

177.8 x 5.6 x 8.3

75.4 x 6.6 x 9.3

191.5 x 16.8 x 23.6

13.2

6

Steel

Vertical rackmount

Vertical rackmount installation supported with included mounting brackets; supports toolless mounting in button-mount compatible racks

Vertical (0U) PDU Form Factor

ENVIRONMENTAL

Relative Humidity

COMMUNICATIONS

SNMP compatibility

0-95% non-condensing

Yes, pre-installed SNMPWEBCARD provides remote monitoring via web, telnet, SSH and SNMP management systems

CERTIFICATIONS

Certifications

WARRANTY

Product Warranty Period

(U.S., Canada & Puerto

Rico)

Tested to UL 60950-1 (USA, Canada), Class A (Emissions), NOM (Mexico), RoHS compliant

2-year limited warranty

Related Items

Optional Products

Product Type Related Model

Environmental Monitoring ENVIROSENSE

Power Cables P005-002

Power Cables

Power Cables

Power Cables

Power Cables

Power Cables

Power Cables

Power Cables

P005-006

P005-010

P032-007

P036-002

P036-006

P047-002

P047-004

Description

Monitors temperature, humidity and contact-closure inputs. (Requires

SNMPWEBCARD or switched PDU.)

2-ft. Heavy-Duty 14AWG Power cord

( IEC-320-C13 to IEC-320-C14)

6-ft. Heavy-Duty 14AWG Power cord

(IEC-320-C13 to IEC-320-C14)

10-ft. Heavy-Duty 14AWG Power cord

(IEC-320-C13 to IEC-320-C14)

7-ft. 12AWG Heavy Duty Power cord

( IEC-320- C13 to IEC-320-C20

2-ft. 12AWG Heavy Duty Power cord

(IEC-320-C19 to IEC-320-C20)

6-ft. 12AWG Heavy Duty Power cord

(IEC-320-C19 to IEC-320-C20)

2-ft. 14AWG Heavy Duty Power cord

(IEC-320-C19 to IEC-320-C14)

4-ft. 14AWG Heavy Duty Power cord

(IEC-320-C19 to IEC-320-C14)

1

1

1

1

Qty.

1

1

1

1

1

Power Cables

Power Cables

P047-006

P047-010

6-ft. 14AWG Heavy Duty Power cord

(IEC-320-C19 to IEC-320-C14)

10-ft. 14AWG Heavy Duty Power cord

(IEC-320-C19 to IEC-320-C14)

Rack door sensor (max. 4); Requires ENVIROSENSE SNMP Accessories SRSWITCH

More information, including related products, owner's manuals, and additional technical specifications, can be found online at www.tripplite.com/en/products/model.cfm?txtModelID=4592 .

1

1

1

Copyright © 2011 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. Photos may differ slightly from final products.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Key Features

  • Three-phase Switched 0U Black
  • LCD
  • 24 AC outlet(s) C13 coupler, C19 coupler
  • 5700 W

Related manuals

Download PDF

advertisement