Tripp Lite SmartOnline 208/120V or 240/120V 16kVA 14.4kW On-Line Double-Conversion UPS, N+1, Extended Run, SNMP, Webcard, 14U Rack/Tower, USB, DB9 Serial Datasheet

Add to my manuals
6 Pages

advertisement

Tripp Lite SmartOnline 208/120V or 240/120V 16kVA 14.4kW On-Line Double-Conversion UPS, N+1, Extended Run, SNMP, Webcard, 14U Rack/Tower, USB, DB9 Serial Datasheet | Manualzz

SmartOnline 208/120V or 240/120V 16kVA 14.4kW

On-Line Double-Conversion UPS, N+1, Extended

Run, SNMP, Webcard, 14U Rack/Tower, USB, DB9

Serial

MODEL NUMBER: SU16KRT-1TF

Highlights

16kVA / 16,000VA / 14,400W on-line double-conversion UPS;

0.9 power factor

208/120V or 240/120V 60Hz compatibility; 96% Efficient

Economy-mode option

Hot-swap power and battery modules, N+1 fault tolerance at loads up to 8kVA

USB, RS232 & EPO ports; support for SNMP/WEB and contact-closure card options

Front panel LEDs with detailed

LCD monitoring and control screen

Expandable runtime with optional external battery packs

Hardwire input (3 wire); L6-30R,

C19, 5-15/20R & 5-15R outlets

Description

Tripp Lite SU16KRT-1TF 16,000VA / 16kVA / 14,400 watt online, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a 14U rack/tower configuration. This system delivers complete N+1 redundancy when used at loads up to 8kVA, and non-redundant operation at loads between 8 and 16kVA. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included parallel PDU with manual bypass switching enables hot-swappable replacement of all major UPS system components in both N+1 and combined operating modes. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations.

Package Includes

Two SU8000RT3UPM UPS power modules

Two BP240V10RT3U battery packs

One SU6000XFMR2U 208/240V to 120V transformer

SUPDMB20K parallel PDU with

Bypass switch

4 post rackmount installation rails

PowerAlert software and cabling

Features

Tripp Lite SU16KRT 16kVA, 16,000VA / 14,400 watt on-line, double-conversion UPS system in 14U total rack/tower configuration

Unique configuration offers 16kVA non-redundant operation and automatic N+1 redundancy at load levels of 8kVA and under

Included Parallel PDU with manual bypass switch enables hot-swap replacement of power modules at any supported load level

Hardwire input; 2 L6-30R (208/240v), 8 C19 (208/240v), 8 5-15/20R (120v) and 4 5-15R (120v) outlets

Maintains full-time sine wave output within 2% of selectable 200/208/220/230/240V & 120V nominal

Expandable runtime with optional external battery packs

Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)

Battery independent restart

Highly efficient economy mode option

Optional SNMPWEBCARD, RELAYIOCARD and RELAYIOMINI interface modules available (RELAYIOMINI requires removal of USB interface module)

Applications utilizing the optional network communications card require two SNMPWEBCARD accessories (install one per included power module)

1 / 6

HID-compliant USB interface

Includes Free PowerAlert monitoring software; PowerAlert LOCAL, PowerAlert NSA and PowerAlert NMS for monitoring up to 250 SNMP-enabled UPS,

PDU and other networking devices

Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks (6 required)

Optional 2-9USTAND supports upright tower placement (2 required)

Supports Emergency Power Off (EPO) via built-in interface

Front panel LEDs and LCD readout with scroll controls

LED / LCD display panel rotates for viewing in rackmount or tower configurations

External battery packs are field replaceable and hot swappable

Specifications

General Info

RoHS Y

OUTPUT

Output Capacity Details

Output Volt Amp Capacity (VA)

Output kVA Capacity (kVA)

Output Watt Capacity (Watts)

Output kW Capacity (kW)

Power Factor

Crest Factor

Nominal Output Voltage(s)

Supported

Nominal Voltage Details

Frequency Compatibility

Frequency Compatibility Details

Output Voltage Regulation (Line

Mode)

Output Voltage Regulation

(Economy Line Mode)

Output Voltage Regulation (Battery

Mode)

Output Receptacles

Output Receptacle Details

+/- 10%

Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power;

Double conversion mode is automatically restored as load levels are reduced to 95% or less

16000

16

14400

14.4

0.9

3:1

120V; 208V; 240V

This configuration requires the Power Module be set to 208 or 240V output voltage; included step-down transformer supports 120V output (when the voltage-selection switch on the transformer module is set to match the 208 or 240V power module setting)

60 Hz

Output frequency regulation +/- 0.05Hz (free running)

+/- 2%

+/- 2%

(4) 5-15R; (8) 5-15/20R; (2) L6-30R; (8) C19

Total 120V output is limited to 4992 watts for 208V input and 5760 watts for 240V input. Additional 120V capacity is available by adding a second SU6000XFMR2U step-down transformer.

2 / 6

Output Circuit Breakers

POWER MODULE: Two built-in 30A breakers protect one L6-30R outlet each, Eight built-in 20A breakers protect one C19 outlet each; TRANSFORMER MODULE: Two 15A breakers protect 2 5-15R outlets each, Two 20A breakers protect 4 5-15/20R outlets each

Output AC Waveform (AC Mode) Pure Sine wave

Output AC Waveform (Battery Mode) Pure Sine wave

INPUT

Rated input current (Maximum Load) 88.4A (208V), 76.6A (240V)

Nominal Input Voltage(s) Supported 208V AC; 240V AC

UPS Input Connection Type Hardwire

UPS Input Connection Description

Recommended Electrical Service

Input Phase

3 wire single phase input (L1, L2, G)

100A @ 208V, or 240V (L1, L2, G)

Single-Phase

BATTERY

Full Load Runtime (min.)

Half Load Runtime (min.)

Expandable Battery Runtime

External Battery Pack Compatibility

Expandable Runtime Description

DC System Voltage (VDC)

Battery Recharge Rate (Included

Batteries)

Battery Replacement Description

5.5 minutes (14,400 watts)

13.5 minutes (7200 watts)

Runtime is expandable with external battery packs

BP240V10RT3U ; BP240V557C-1PH ; BP240V787C-1PH ; BP240V1037C-1PH ; BP240V1407C-1PH

For best results, add external batteries in multiples of two so that both included 8kVA power modules have an equal number and type of connected battery packs

240

Less than 6 hours from 10% to 90% (typical, full load discharge)

Hot-swappable, user replaceable external battery packs

VOLTAGE REGULATION

Voltage Regulation Description

Overvoltage Correction

Undervoltage Correction

2% output voltage regulation in standard online, double-conversion mode

Corrects overvoltages up to 300V

Corrects undervoltages as low as 100V

USER INTERFACE, ALERTS & CONTROLS

Front Panel LCD Display

Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options;

LED/LCD panel rotates for viewing in rack/tower formats; LCD Display supports ENGLISH, FRENCH, GERMAN,

ITALIAN, SPANISH and PORTUGUESE (see manual)

Switches

Alarm Cancel Operation

Audible Alarm

2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module replacement

Alarm cancel switch

Unique audible alarms for all major UPS, environmental and power conditions (see manual)

3 / 6

LED Indicators

6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options

SURGE / NOISE SUPPRESSION

UPS AC Suppression Response

Time

EMI / RFI AC Noise Suppression

Instantaneous

Yes

PHYSICAL

Included Mounting Accessory

Description

5 sets of adjustable 4 post rack rails included (one for each included 2U/3U module)

Installation Form Factors Supported with Optional Accessories

2 post rackmount (2POSTRMKITHD); Tower (2-9USTAND)

Optional Mounting Accessory Notes Qty 5 2POSTRMKITHD required for 2 post rackmount installation; Qty 2 2-9USTAND required for tower installation

Primary Form Factor Rackmount

UPS Power Module Dimensions

(hwd, in.)

UPS Power Module Dimensions

(hwd, cm)

Installed Whole System Maximum

Rack Depth (in.)

Installed Whole System Maximum

Rack Depth (cm)

Rack Height (U Spaces)

UPS Power Module Weight (lbs.)

UPS Power Module Weight (kg)

5.14 x 17.5 x 25.82

13.1 x 44.5 x 65.6

32.5

82.6

UPS Dimensions Details

14

43

19.5

Includes 2 SU8000RT3UPM UPS/Power modules and 2 BP240V10RT3U Battery packs; Listed weights and dimensions for UPS/Power module and Included battery pack each refer to a single unit

Stepdown Transformer Dimensions

(hwd / in.)

Stepdown Transformer Dimensions

(hwd / cm)

3.5 x 17.5 x 21.8

8.89 x 44.4 x 55.4

Stepdown Transformer Weight (lbs.) 72.6

Stepdown Transformer Weight (kg) 33

Included Battery Pack Dimensions

(hwd / in.)

Included Battery Pack Dimensions

(hwd / cm)

5.25 x 17.5 x 25

13.3 x 44.5 x 63.5

Included Battery Pack Weight (lbs.)

Included Battery Pack Weight (kg)

158.7

72

UPS Shipping Dimensions (hwd / in.) 36 x 40.25 x 51

4 / 6

UPS Shipping Dimensions (hwd / cm)

Shipping Weight (lbs.)

Shipping Weight (kg)

Cooling Method

UPS Housing Material

91.4 x 102.2 x 129.5

677

307.4

Fans

Steel

ENVIRONMENTAL

Operating Temperature Range

Storage Temperature Range

Relative Humidity

AC Mode BTU / Hr. (Full Load)

AC Economy Mode BTU / Hr. (Full

Load)

2046

AC Mode Efficiency Rating (100%

Load)

90%

AC Economy Mode Efficiency Rating

(100% Load)

96%

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.

0 to 95%, non-condensing

5456

Operating Elevation (ft.)

Audible Noise

Operating Elevation (m)

0-3000m (0 to 10,000 ft.)

60 dBA at front side 1 meter

0-3000 m

COMMUNICATIONS

Communications Interface

Network Monitoring Port Description

PowerAlert Software

Communications Cable

WatchDog Compatibility

USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface

Applications utilizing the optional network communications card require two SNMPWEBCARD accessories (install one per included power module); Additional contact closure support with optional RELAYIOCARD and

RELAYIOMINI interface cards; RELAYIOMINI installation requires removal of panel containing USB ports

Included

USB, DB9 serial and EPO cables included

Supports Watchdog application, OS and hard-reboot restart options for remote applications

LINE / BATTERY TRANSFER

Transfer Time

Transfer Time (Economy Mode)

Low Voltage Transfer to Battery

Power (Setpoint)

High Voltage Transfer to Battery

Power (Setpoint)

No transfer time (0 ms.) in online, double-conversion mode

8 milliseconds typical power failure response in optional economy mode

100V

300V

SPECIAL FEATURES

5 / 6

Cold Start (Startup in Battery Mode

During a Power Failure)

Economy Mode Operation

High Availability UPS Features

Green Energy-Saving Features

Cold-start operation supported

Optional economy mode enables high efficiency bypass operation with a maximum output voltage variation of

+/-10%. Double conversion mode is automatically restored as mains voltage varies beyond +/-10% with less than 1 millisecond transfer time between modes.

Automatic inverter bypass; Manual bypass switch; Detachable hot-swap PDU; Hot swappable UPS power module;

Hot swappable batteries

High efficiency economy mode operation; Support for daily startup and shutoff; Schedulable daily hours of economy mode operation

CERTIFICATIONS

UPS Certifications

UPS Certification Details

Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category A (EMI); ROHS (Restriction of

Hazardous Substances)

IEC 61000-4-5 1995 B Surge Immunity

WARRANTY

Product Warranty Period (Worldwide) 2-year limited warranty

Connected Equipment Insurance

(U.S., Canada & Puerto Rico)

$250,000 Ultimate Lifetime Insurance

© 2015 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement.

Specifications are subject to change without notice. Photos may differ slightly from final products.

6 / 6

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Key Features

  • Double-conversion (Online)
  • 16 kVA 14400 W
  • 22 AC outlet(s)
  • Rackmount/Tower Black

Related manuals

Download PDF

advertisement