Optimus UP-508P UNIDAD POTENCIA OPTIMUS 500W 230/24 manual
Add to my manuals
7 Pages
Optimus UP-508P is a power amplifier unit designed for general civic sound recording applications. It offers two inputs with independent volume control and LINK auxiliary outputs for connecting more units in cascade. The priority input with a dedicated LED indicator overrides the program input, activating a relay output for safety systems. The unit provides protection against output short circuits and over temperature. The loudspeaker audio power outputs are arranged for connection with constant impedance lines and constant voltage lines.
advertisement
UP508P.doc
OPTIMUS s/a
POWER UNITS
UP 508 P
Owner’s Manual
OPTIMUS, S.A. – C. Barcelona, 101 E-17003 GIRONA
Tel +34 972 203 300 - Fax +34 972 218 413
E-mail: [email protected]
1
PUBLIC ADDRESS SERIES
PRIORITY POWER UNITS
UP508P
GENERALITY
Monophonic power units have been designed general applications in civic sound recording field.
P.Us. have 2 inputs arranged with independent volume control.
Each input, electronically balanced (on XLR connectors), has a LINK auxiliary output for cascade connection of more power units.
PRIORITY input (on 5 pin DIN connectors) gets priority on PROGRAM input (on DIN connectors).
At the same time of priority activation, the exchange on SECIRITY PAGING connector contact happens for using in safety systems with 3-wire lines.
To activate the priority input, it is enough to plug 2 and 5 pins of DIN connector.
Units are equipped with protections against output short circuits and against over temperature.
On the front panel there are: power leds, priority and protection leds.
The unit has a natural dissipation cooling system.
Loudspeaker audio power outputs are arranged for connection with constant impedance lines and constant voltage lines.
The whole electronic circulation has quality and safety features in working.
Metal framing is suitable to be supported on a surface (table, etc.) and is equipped with separated stirrups for assembly in 19” rack.
UP508P also has vu-meter for output power indication on the front panel. Forced ventilation cooling system has a variable speed in function of the temperature.
UP508P.doc 2
POWER SUPPLY
The unit is expected to work with 230 VCA – 50/60 distribution system and with 24 VCC battery.
In case of power dysfunction, check the outside and inside protection fuses (for 24 VCC) and eventually replace them with others of same calibration; if one of them burns out immediately, do not go on and have check the unit by qualified personnel.
Take away plug from 230 VCA electric power socket and 24 VCC battery always, before removing fuses and, in any case, open the unit framing.
ACOUSTIC SPEAKER CONNECTIONS
Unit is supplied with a crossbar output terminal board for connection with constant impedance and voltage lines.
- CONSTANT IMPEDANCE LINES
2, 4, 8 and 16 Ohms terminals should be used, using the legend layout.
In order to achieve the maximum efficiency of the system and to take precautions from amplifier bad working, it is necessary to check the effective loading impedance of the lines. The total speakers impedance should be equal or higher than pre-selected value for connection.
To get that, each loudspeaker should be without transformer and should be connected in series or in series-parallel groups; In any case loudspeakers should also have the same power handling
(see fig. 2a).
- CONSTANT VOLTAGE LINES
50 V, 100 V terminals should be used with each loudspeaker provided with line transformer and parallel connected, using the legend layout. See fig. 2b for 2-wire traditional connection and fig. 2c for 3-wire safety connection.
In order to achieve the maximum efficiency of the system and to take precautions from amplifier bad working, it is necessary to check the effective total power handling of the loudspeakers that has to be equal or lower than the RMS power value of used amplifier. It’s a good rule arranging a
10-20% safety margin on the amplifier power capability (see fig. 2b).
UP508P.doc 3
TECHNICAL FEATURES
UP 508 P
Nominal output Power
Peak output Power
Frequency response (- 3 dB)
Distorsion at full power (at 1K Hz)
S/N ratio
Input sensitivity
Input Impedence
Loudspeaker Output: Costant Impedence
Loudspeaker Output: Costant Voltage
Power requirements: Supply CA
Battery
Power consumption at full power
Dimensions (W x H x D)
Weight
500W RMS
50
700W IHF
÷
15.000 Hz
< 1 %
> 90 dB
(0 dB) 775 mV
47K Ohm
2 – 4 - 5 – 8 – 16 – 20 Ohm
31 – 45 – 50 – 63 – 90 – 100 V
230 VCA 50/60 Hz
24V CC
880 VA
443 x 132 x 330 mm
24 Kg
UP508P COMMANDS AND FUNCTIONS (see fig.1)
1. PROGRAM – “PROGRAM” volume input signal.
2. PRIORITY – “PRIORITY” volume input signal.
3. PRIORITY – Activated priority control signal led.
4. PROTECT – Protection intervention signal led.
5. OUT LEVEL – Output level and power indicator.
6. ON/OFF – Power supply switch.
7. INPUT – Balanced DIN input of “PROGRAM” signal.
8. LINK – DIN output for connection to other power unit.
9. PRIORITY INPUT – Balanced DIN input of priority signal.
10. PRIORITY LINK - DIN output for connecting priority signal to other power units.
11. SECURITY PAGING – Auxiliary relay output of safety warning.
12. POWER OUTPUTS - Loudspeaker line outputs.
13. BATT. SUPPLY – 24VCC power supply for external battery.
14. MAINS – 230VAC power supply socket mains with CA mains protection fuse (delayed).
UP508P.doc 4
FIG. 1
UP508P.doc 5
8Ω
4Ω
4Ω
4Ω
4Ω
4Ω
4Ω
4Ω
UP508P.doc
SECURITY
PAGING
-C S +
-
ATTENUATORE
+
-C S +
-
ATTENUATORE
+
6
UP508P.doc 7
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement