The Tripp Lite SU2200RTXL2UN is a high-performance UPS system that provides reliable power protection for critical server and network equipment in data centers, computer rooms, and network closets. With its 2.2kVA power capacity and 1600-watt output, it can support a variety of devices, including servers, workstations, networking gear, and telecommunications equipment. The SU2200RTXL2UN features double-conversion technology, which ensures a consistent and clean power supply, even during power fluctuations or outages.
advertisement
SmartOnline 120V 2.2kVA 1.6kW On-Line
Double-Conversion UPS, Extended Run, SNMP,
Webcard pre-installed, 2U Rack/Tower, USB, DB9
Serial
MODEL NUMBER: SU2200RTXL2UN
Highlights
2200VA / 2.2kVA / 1600 watt on-line double-conversion 2U rack/tower UPS
110/120V +/-2% output at
50/60Hz, high 97% efficiency economy mode option
Expandable runtime, Hot-swap batteries; 19 in / 48.3cm installed depth
USB, RS232, EPO ports and
PRE-INSTALLED
SNMPWEBCARD
Front panel status LEDs with detailed load and battery metering
2 independently switchable output load banks
NEMA 5-20P input; L5-20R &
5-15/20R outlets
Description
Tripp Lite Smart Online UPS systems offer high performance power protection ideal for critical server and network equipment in datacenters, computer rooms and network closets. Online, double-conversion
Uninterruptible Power Supply (UPS) maintains perfectly regulated output power by continuously converting raw
AC input to DC, then re-converting output back to AC. Fully regulated sine wave AC output with +/-2% voltage regulation powers network equipment continuously, even during severe brownouts and overvoltages, all without depleting UPS battery reserves. Maintains battery-derived AC output during power failures with zero transfer time. Extended runtime options available. High 97% efficient operation in optional economy mode saves BTU heat output and energy costs. Network management interfaces support communications via USB, RS-232, contact-closure and PRE-INSTALLED SNMPWEBCARD network interface. Built-in DB9 port offers both
Applications
Distributed Server Rooms
Network Closets
Small Business Networks
Voice over IP (VoIP) Phone
Systems
Package Includes
SU2200RTXL2UN UPS with enhanced RS-232 data and basic contact closure monitoring ability. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Includes
PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. LED display reports UPS operating mode, line power availability, battery mode operation, inverter operation and output
Pre-installed SNMPWEBCARD
PowerAlert Software and cabling
Mounting hardware for 4 post rack enclosures
Instruction manual power availability. Audible alarm with push-button momentary alarm-cancel. Programmable self-test. Battery independent restart. Fault-tolerant auto-bypass mode. Field-replaceable, hot-swappable internal batteries and external battery packs.
Features
Tripp Lite SU2200RTXL2UN 2200VA / 2.2kVA / 1600W on-line, double-conversion 3U rackmount UPS
Selectable 110/120V output (120V factory preset)
NEMA 5-20P input, 6 NEMA 5-15/20R & 1 L5-20R
Two switched 3-outlet load banks support remote reboot or programmable load shedding options
Supports 2% output voltage regulation and zero transfer time in double conversion mode
Economy mode option offers enhanced 97% efficiency operation, reduced power consumption and lower BTU emissions
1 / 5
14 minutes runtime at 50% load (800W) and 4.5 minutes at 100% load (1600W) with internal batteries
BP48V24-2U (limit 1), BP48V60RT-3U (multi-pack compatible) and BP48V27-2US (multi-pack compatible) external battery packs available (some configurations require Tripp Lite's External Battery Configuration Software)
LED Display reports UPS operating mode, line power availability, battery mode operation, inverter status and output power availability
Audible alarm with push-button momentary alarm-cancel
4 post installation hardware included, Optional 2POSTRMKITWM enables 2 post rack installation
Single line TEL / Network surge suppression
Electronic bypass maintains utility output during a variety of UPS fault conditions
Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement
Built-in USB, RS-232, contact-closure and SNMPWEBCARD network interface
HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
Included PowerAlert UPS monitoring software
Specifications
General Info
RoHS Y
OUTPUT
Output Volt Amp Capacity (VA)
Output kVA Capacity (kVA)
Output Watt Capacity (Watts)
Output kW Capacity (kW)
Power Factor
Crest Factor
Nominal Output Voltage(s)
Supported
Nominal Voltage Details
Frequency Compatibility
Frequency Compatibility Details
Output Voltage Regulation (Line
Mode)
Output Voltage Regulation
(Economy Line Mode)
Output Voltage Regulation (Battery
Mode)
Output Receptacles
Load Management Receptacles
Output AC Waveform (AC Mode)
+/- 10%
2200
2.2
1600
1.6
0.7
3:1
110V; 120V
120V default
50 / 60 Hz
Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start
+/- 2%
+/- 2%
(6) 5-15/20R; (1) L5-20R
Two switchable three-outlet 5-15/20R load banks
Sine wave
2 / 5
Output AC Waveform (Battery Mode) Pure Sine wave
INPUT
Rated input current (Maximum Load) 16A
Nominal Input Voltage(s) Supported 110V AC; 120V AC
UPS Input Connection Type 5-20P
Input Circuit Breakers
UPS Input Cord Length (ft.)
UPS Input Cord Length (m)
UPS Input Cord Length Details
Recommended Electrical Service
Input Phase
30A
10
3
Built-in
20A 120V
Single-Phase
BATTERY
Full Load Runtime (min.)
Half Load Runtime (min.)
Expandable Battery Runtime
External Battery Pack Compatibility
Expandable Runtime Description
DC System Voltage (VDC)
Battery Recharge Rate (Included
Batteries)
Internal UPS Replacement Battery
Cartridge
Battery Access
Battery Replacement Description
4.5 min. (1600w)
14 min. (800w)
Extended runtime supported via optional external battery packs
BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible)
BP48V24-2U (limit 2 w/ 48VDCSPLITTER)
48
Less than 6 hours from 10% to 80% (typical, full load discharge)
RBC94-2U
Front panel battery access door
Hot-swappable, user replaceable sealed, flame retardant, non-spillable batteries
VOLTAGE REGULATION
Voltage Regulation Description
Overvoltage Correction
Undervoltage Correction
Severe Undervoltage Correction
Online, double-conversion power conditioning
2% output voltage regulation during overvoltages to 150
2% output voltage regulation during undervoltages to 80
2% output voltage regulation during undervoltages to 65 (under 70% load only)
USER INTERFACE, ALERTS & CONTROLS
Switches 2 switches control off/on power status and alarm-cancel/self-test operation
Alarm Cancel Operation
Audible Alarm
Power-fail alarm can be silenced using alarm-cancel switch
Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
3 / 5
LED Indicators
14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in rack/tower formats
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating
UPS AC Suppression Response
Time
UPS Dataline Suppression
EMI / RFI AC Noise Suppression
570
Instantaneous
1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet
Yes
PHYSICAL
Included Mounting Accessory
Description
Installation Form Factors Supported with Optional Accessories
Primary Form Factor
Includes 4 post rackmount installation accessories
2 post rackmount (2POSTRMKITWM); Wallmount (2POSTRMKITWM); Tower (2-9USTAND)
Rackmount
UPS Power Module Dimensions
(hwd, in.)
UPS Power Module Dimensions
(hwd, cm)
3.5 x 17.5 x 19
8.9 x 44.4 x 48.3
Rack Height (U Spaces)
UPS Power Module Weight (lbs.)
2
47.4
UPS Power Module Weight (kg) 21.5
UPS Shipping Dimensions (hwd / in.) 9.8 x 20.2 x 24
UPS Shipping Dimensions (hwd / cm)
24.8 x 51.4 x 61
Shipping Weight (lbs.)
Shipping Weight (kg)
Cooling Method
UPS Housing Material
57.3
26
Fan
Steel
ENVIRONMENTAL
Operating Temperature Range
Storage Temperature Range
Relative Humidity
AC Mode BTU / Hr. (Full Load)
AC Economy Mode BTU / Hr. (Full
Load)
Battery Mode BTU / Hr. (Full Load)
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
0 to 95%, non-condensing
812.9
347.2
885.6
4 / 5
AC Mode Efficiency Rating (100%
Load)
87%
AC Economy Mode Efficiency Rating
(100% Load)
94%
Audible Noise < 45dB at 1m
COMMUNICATIONS
Communications Interface
Network Monitoring Port Description
PowerAlert Software
Communications Cable
WatchDog Compatibility
Contact closure; DB9 Serial; EPO (emergency power off); Pre-installed network card; Slot for SNMP/Web interface;
USB (HID enabled)
Includes PRE-INSTALLED SNMPWEBCARD interface card. Supports detailed monitoring of UPS and site power conditions
Included
USB and DB9 cabling included
Supports Watchdog application, OS and hard-reboot restart options for remote applications
LINE / BATTERY TRANSFER
Transfer Time
Low Voltage Transfer to Battery
Power (Setpoint)
High Voltage Transfer to Battery
Power (Setpoint)
No transfer time (0 ms.) in online, double-conversion mode
80V (100% load), 65V ( <70% load)
150
SPECIAL FEATURES
Cold Start (Startup in Battery Mode
During a Power Failure)
High Availability UPS Features
Green Energy-Saving Features
Cold-start operation supported
Automatic inverter bypass; Hot swappable batteries
High efficiency economy mode operation; Individually controllable load banks; Schedulable daily hours of economy mode operation
CERTIFICATIONS
UPS Certifications Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)
WARRANTY
Product Warranty Period (Worldwide) 2-year limited warranty
Connected Equipment Insurance
(U.S., Canada & Puerto Rico)
$250,000 Ultimate Lifetime Insurance
© 2015 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement.
Specifications are subject to change without notice. Photos may differ slightly from final products.
5 / 5
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Key Features
- Double-conversion (Online)
- 2.2 kVA 1600 W
- Waveform: Sine
- 7 AC outlet(s)
- Rackmount/Tower Black
Related manuals
advertisement