Cisco 16GB USB Datasheet

Add to my manuals
68 Pages

advertisement

Cisco 16GB USB Datasheet | Manualzz

Spec Sheet

Cisco UCS C22 M3

High-Density Rack-Mount

Server

(Small Form Factor Hard

Disk Drive Model)

C ISCO S YSTEMS

170 W EST T ASMAN D R .

S AN J OSE , CA, 95134

WWW .

CISCO .

COM

P UBLICATION H ISTORY

R EV B.14

J ANUARY 5, 2015

CONTENTS

OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

DETAILED VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Chassis Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Chassis Rear View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

BASE SERVER STANDARD CAPABILITIES and FEATURES . . . . . . . . . . . . . . . . . 6

CONFIGURING the SERVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

STEP 1 VERIFY SERVER SKU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

STEP 2 SELECT CPU(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

STEP 3 SELECT MEMORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

STEP 4 SELECT RAID CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

STEP 5 SELECT DRIVES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

STEP 6 SELECT PCIe OPTION CARD(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . 26

STEP 8 SELECT AC POWER CORD(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

STEP 9 ORDER POWER SUPPLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM . . . . . . . . . . . . . . . . . 34

STEP 11 ORDER A TRUSTED PLATFORM MODULE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

STEP 12 ORDER OPTIONAL USB 2.0 DRIVE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

STEP 13 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE . . . . . . . . . . . . . . . . 37

STEP 14 SELECT OPERATING SYSTEM MEDIA KIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

STEP 15 SELECT SERVICE and SUPPORT LEVEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

OPTIONAL STEP - ORDER RACK(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

OPTIONAL STEP - ORDER PDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

SUPPLEMENTAL MATERIAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

CHASSIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

CPUs and DIMMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

Physical Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

Memory Population Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

Recommended Memory Population . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52

Additional DIMM Populations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

Low-Voltage DIMM Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

RAID Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

RAID Option ROM (OPROM) Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56

RACKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

PDUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59

Motherboard USB Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60

LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63

TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65

Dimensions and Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65

Power Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65

Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

Compliance Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 2

OVERVIEW

OVERVIEW

The Cisco® UCS C22 M3 small form factor (SFF) drive Rack Server combines economics and a density-optimized feature set from entry level enterprise to SMB with applications such as scale out, virtualization, IT and web infrastructure, VPN servers, file/print servers, and appliances.

Building on the success of the Cisco UCS C-Series Servers, the Cisco UCS C22 M3 server and the Cisco 1225

VIC further extend the capabilities of the Cisco UCS portfolio in a 1RU form factor with the addition of the

Intel® Xeon® E5-2400 v2 and E5-2400 series processor family CPUs, which delivers the best combination of performance and efficiency gains. In addition, the Cisco UCS C22 M3 server offers 12 DIMM slots, up to eight disk drives, two PCIe slots and two 1 Gigabit Ethernet LAN-on-motherboard (LOM) ports that provide both price/performance in a compact 1U form factor.

Figure 1 Cisco UCS C22 M3 High-Density SFF Rack Server

Front View

Rear View

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 3

DETAILED VIEWS

DETAILED VIEWS

Chassis Front View

Figure 2 shows the Cisco UCS C22 M3 High-Density SFF Rack Server.

Figure 2 Chassis Front View

1 2 3 4 5 6 7 8

9

3

4

1

2

5

Power button/power status LED

Identification button/LED

System status LED

Fan status LED

Temperature status LED

HDD01

HDD06

10

HDD02

HDD07

HDD03

HDD08

8

9

6

7

10

Power supply status LED

Network link activity LED

USB 2.0 ports (two)

Pull-out asset tag

Drives

(up to eight hot-swappable 2-5-inch drives)

4 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server

DETAILED VIEWS

Chassis Rear View

Figure 3 shows the external features of the rear panel.

Figure 3 Chassis Rear View

1 2 3

1

2

3

4

5

4

Power supply

Slot 2: Low-profile PCIe slot on riser 2

PCIe Gen 3 slot, x8, half-height, half-length

Slot 1: Standard-profile PCIe slot on riser 1

PCIe Gen 3 slot, x16, full-height, half-length

Dual 1-Gb Base-T Ethernet ports (two)

USB 2.0 ports (four)

6

7

8

9

5 6 7 8 9

Serial port (DB-9 connector)

VGA video port (DB-15 connector)

10/100/1000 Base-T Ethernet dedicated management port

Rear Identification button/LED

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 5

BASE SERVER STANDARD CAPABILITIES and FEATURES

BASE SERVER STANDARD CAPABILITIES and FEATURES

Table 1

lists the capabilities and features of the base server. Details about how to configure the server for a particular feature or capability (for example, number of processors, disk drives, or amount of memory)

are provided in CONFIGURING the SERVER, page 9

.

Table 1 Capabilities and Features

Capability/Feature

Chassis

CPU

Chipset

Memory

NIC

Expansion slots

Internal storage devices

Video

Description

Single rack unit (1RU) chassis

One or two Intel® Xeon E5-2400 v2 or E5-2400 series processor family CPUs

Intel C600 chipset

12 DIMM slots

Embedded dual-port Intel I350 PCIe-based Gigabit Ethernet controller

Two riser cards with one PCIe card slot in each riser

■ Riser 1 (controlled by CPU 1)

• Slot 1: PCIe Gen 3 slot, x16 extended connector (Cisco CNIC), half-length, full-height, with NCSI 1 and Cisco CNIC 2 support. The

Cisco 1225 virtual interface card requires an NCSI slot.

■ Riser 2 (controlled by CPU 2)

• Slot 2: PCIe Gen 3 slot, x8 connector, half-length, half-height, no

NCSI support

■ Up to eight 2.5-inch SAS+SATA hot-swappable hard disk drives (HDDs) or solid state drives (SSDs)

■ One connector on the motherboard that can accommodate a USB 2.0 drive. You can order an 8 or 16 GB drive for this connector and use it as a hypervisor or license dongle. The 8 or 16 GB USB drive comes blank.

The Emulex Pilot 3 Integrated Baseboard Management Controller provides video:

■ Matrox G200e video controller

■ Integrated 2D graphics core with hardware acceleration

■ Supports all display resolutions up to 1920 x 1200 x 16 bpp resolution at

60 Hz

24-bit color depth for all resolutions less than 1600x1200

8 MB video memory

6 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server

Capability/Feature

Storage controller

Interfaces

Front Panel

Power subsystem

Fans

BASE SERVER STANDARD CAPABILITIES and FEATURES

Description

The following RAID options are available:

■ Embedded RAID (3 Gbps) (these implementations of RAID do not consume a PCIe slot).

• Embedded SATA-only RAID controller, supporting up to four SATA-only drives (RAID 0, 1, 10), or

• ROM5 RAID upgrade, supporting up to eight SAS+SATA drives (RAID 0,

1, 10), or

• ROM55 RAID upgrade, supporting up to eight SAS+SATA drives (RAID 0,

1, 5, 10).

PCIe RAID controllers (these consume PCIe slots)

• LSI MegaRAID 9270CV-8i with 1 GB Transportable Memory Module

(TMM) data cache and chassis-mounted (remote) supercap for data cache power backup, supporting RAID 0, 1, 5, 6, 10, 50, and 60 and up to eight internal SAS+SATA drives.

• LSI MegaRAID 9240-8i RAID 8-port PCIe RAID controller, supporting

RAID 0, 1, 5, 10, and 50 and up to eight internal SAS+SATA drives.

• LSI MegaRAID 9220-8i RAID 8-port PCIe RAID controller supporting

RAID 0, 1, and 10 and up to eight internal SAS+SATA drives.

Rear panel

• One DB9 serial port connector

• Four USB 2.0 port connectors

• One DB15 VGA connector

• One 10/100/1000 Ethernet management port

• Two 1 GbE (10/100/1000 Mbps capable) Ethernet LOM ports

Front panel

• Two USB 2.0 ports

■ A front panel controller provides status indications and control buttons

One 450 W power supply or one 650 W power supply, depending on server configuration and loading. Prior to making a power supply selection, the UCS

Power Calculator should be run to determine the right size power supply for your server configuration. A fully configured C22 M3 server may require the

650 W power supply. The UCS Power Calculator can be found at the following link: https://mainstayadvisor.com/Go/Cisco/Cisco-UCS-Power-Calculator.aspx

Chassis:

■ Five fans for front-to-rear cooling. N + 1 redundant.

Power supply:

■ The power supply is equipped with a fan.

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 7

BASE SERVER STANDARD CAPABILITIES and FEATURES

Capability/Feature

Integrated management processor

Description

Cisco Integrated Management Controller (CIMC).

Depending on your CIMC settings, the CIMC can be accessed through the 1-Gb

Ethernet dedicated management port, the 1-Gb Ethernet LOM ports, or a

Cisco 1225 virtual interface card.

Notes . . .

1. NCSI = network communications services interface protocol. The slot stays active when the server is in standby power state.

2. CNIC = Cisco network interface card.

8 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server

CONFIGURING the SERVER

CONFIGURING the SERVER

Follow these steps to configure the Cisco UCS C22 M3 High-Density SFF Rack Server:

STEP 1 VERIFY SERVER SKU, page 10

STEP 2 SELECT CPU(s), page 11

STEP 3 SELECT MEMORY, page 13

STEP 4 SELECT RAID CONFIGURATION, page 17

STEP 5 SELECT DRIVES, page 22

STEP 6 SELECT PCIe OPTION CARD(s), page 24

STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES, page 26

STEP 8 SELECT AC POWER CORD(s), page 30

STEP 9 ORDER POWER SUPPLY, page 33

STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM, page 34

STEP 11 ORDER A TRUSTED PLATFORM MODULE, page 35

STEP 12 ORDER OPTIONAL USB 2.0 DRIVE, page 36

STEP 13 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE, page 37

STEP 14 SELECT OPERATING SYSTEM MEDIA KIT, page 40

STEP 15 SELECT SERVICE and SUPPORT LEVEL, page 41

OPTIONAL STEP - ORDER RACK(s), page 46

OPTIONAL STEP - ORDER PDU, page 47

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 9

CONFIGURING the SERVER

STEP 1 VERIFY SERVER SKU

Verify the product ID (PID) of the server as shown in

Table 2

.

Table 2 PID of the C22 M3 High-Density SFF Rack Base Server

Product ID (PID)

UCSC-C22-M3S UCS C22 M3 SFF with rail kit, without PSU, CPU, memory, HDD, SSD, or PCIe cards

Description

The Cisco C22 M3 server:

Includes a rail kit (UCSC-RAIL1)

Does not include power supply, CPU, memory, hard disk drives (HDDs), solid state drives

(SSDs), or plug-in PCIe cards.

NOTE: Use the steps on the following pages to configure the server with the components that you want to include.

10 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server

CONFIGURING the SERVER

STEP 2 SELECT CPU(s)

The standard CPU features are:

Intel Xeon E5-2400 v2 or E5-2400 series processor family CPUs

Intel C600 chipset

Cache size of up to 25 MB

Select CPUs

The available CPUs are listed in Table 3

.

Table 3 Available Intel CPUs: Xeon E5-24xx Family

Product ID (PID)

Intel

Number

Clock

Freq

(GHz)

Power

(W)

Cache

Size

(MB)

Cores

QPI

(GT/s)

Highest DDR3

DIMM Clock

Support

(MHz) 1

Intel Xeon E5-2400 v2

UCS-CPU-E52470B E52470 v2

UCS-CPU-E52450B

UCS-CPU-E52440B

E52450 v2

E52440 v2

UCS-CPU-E52430B

UCS-CPU-E52430LB

UCS-CPU-E52420B

UCS-CPU-E52407B

E52430 v2

E52430L v2

E52420 v2

E52407 v2

E52403 v2 UCS-CPU-E52403B

Intel Xeon E5-2400

UCS-CPU-E5-2470

UCS-CPU-E5-2450

UCS-CPU-E5-2440

UCS-CPU-E5-2430

UCS-CPU-E5-2430L

E5-2470

E5-2450

E5-2440

E5-2430

E5-2430L

UCS-CPU-E5-2420

UCS-CPU-E5-2407

UCS-CPU-E5-2403

E5-2420

E5-2407

E5-2403

2.4

2.5

1.9

2.5

2.4

2.2

2.4

1.8

2.30

2.10

2.40

2.20

2.00

1.90

2.20

1.80

95

95

95

80

60

80

80

80

95

95

95

95

60

95

80

80

25

20

20

15

15

15

10

10

20

20

15

15

15

15

10

10

10

8

8

6

6

6

4

4

8

8

6

6

6

6

4

4

8.0

8.0

7.2

7.2

7.2

7.2

6.4

6.4

8.0

8.0

7.2

7.2

6.4

7.2

6.4

6.4

1600

1600

1600

1600

1600

1600

1333

1333

Notes . . .

1. If higher or lower speed DIMMs are selected than what is shown in the table for a given CPU, the DIMMs will be clocked at the lowest common denominator of CPU clock and DIMM clock.

1600

1600

1333

1333

1333

1333

1066

1066

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 11

CONFIGURING the SERVER

Approved Configurations

(1) 1-CPU configurations:

■ Select any one CPU listed in

(2) 2-CPU Configurations:

Table 3 .

Select two identical CPUs from any one of the rows of Table 3 on page 11

.

Caveats

You can select either one CPU or two identical CPUs.

If you select one CPU, only one PCIe slot (the full-height slot on riser 1) is available for use.

For optimal performance, select DIMMs with the highest clock speed for a given processor

(see Table 3 on page 11

). If you select DIMMs whose speeds are lower or higher than that shown in the tables, suboptimal performance will result.

12 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server

CONFIGURING the SERVER

STEP 3 SELECT MEMORY

Figure 4

The standard memory features are:

DIMMs

— Clock speed: 1600 or 1333 MHz

— Ranks per DIMM: 1, 2, or 4

— Operational voltage: 1.35 V or 1.5 V

— Registered ECC DDR3 DIMMS (RDIMMS), unregistered DIMMs (UDIMMs), or load-reduced DIMMs (LRDIMMs)

Memory is organized with three memory channels per CPU, with up to two DIMMs per channel, as shown in

Figure 4

.

C22 M3 SFF Memory Organization

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 13

CONFIGURING the SERVER

Select DIMMs

Select the memory configuration. The available memory DIMMs are listed in

Table 4

.

NOTE: When memory mirroring is enabled, the memory subsystem simultaneously writes identical data to two channels. If a memory read from one of the channels returns incorrect data due to an uncorrectable memory error, the system automatically retrieves the data from the other channel. A transient or soft error in one channel does not affect the mirrored data, and operation continues unless there is a simultaneous error in exactly the same location on a DIMM and its mirrored

DIMM. Memory mirroring reduces the amount of memory available to the operating system by 50% because only one of the two populated channels provides data.

Table 4 Available DDR3 DIMMs

Product ID (PID) PID Description

DIMM Options

UCS-MR-1X041RY-A

UCS-MR-1X082RY-A

UCS-MR-1X162RY-A

UCS-ML-1X324RY-A

4GB DDR3-1600-MHz RDIMM/PC3-12800/1R/x4/1.35v

8GB DDR3-1600-MHz RDIMM/PC3-12800/2R/x4/1.35v

16GB DDR3-1600-MHz RDIMM/PC3-12800/2R/x4/1.35v

32GB DDR3-1600-MHz LR DIMM/PC3-12800/4R/x4/1.35v

Memory Mirroring Option

N01-MMIRROR Memory mirroring option

Voltage

1.35 V

1.35 V

1.35 V

1.35 V

Ranks

/DIMM

1

2

2

4

14 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server

CONFIGURING the SERVER

Approved Configurations

(1) 1-CPU configuration without memory mirroring:

■ Select from 1 to 6 DIMMs. Refer to

Memory Population Rules, page 51 , for more detailed

information.

(2) 1-CPU configuration with memory mirroring:

■ Select either 2 or 4 DIMMs. The DIMMs will be placed by the factory as shown in the following table:

Number of

DIMMs

2

4

DIMM Placement in Channels

(Channel A is not used with memory mirroring)

CPU 1: 1 DIMM in Channel B, 1 DIMM in Channel C

CPU 1: 2 DIMMs in Channel B, 2 DIMMs in Channel C

Select the memory mirroring option (N01-MMIRROR) as shown in

(1) 2-CPU configuration without memory mirroring:

Table 4 on page 14 .

Select from 1 to 6 DIMMs per CPU (2 to 12 DIMMs total). Refer to Memory Population Rules, page 51

, for more detailed information.

(2) 2-CPU configuration with memory mirroring:

■ Select 2 or 4 DIMMs per CPU (4 or 8 DIMMs total). The DIMMs will be placed by the factory as shown in the following table:

Number of

DIMMs per

CPU

2

4

CPU 1:

1 DIMM in Channel B

1 DIMM in Channel C

CPU 1:

2 DIMMs in Channel B

2 DIMMs in Channel C

DIMM Placement

(Channels A and D are not used with memory mirroring)

CPU 2:

1 DIMM in Channel E

1 DIMM in channel F

CPU 2:

2 DIMMs in Channel E

2 DIMMs in Channel F

Select the memory mirroring option (N01-MMIRROR) as shown in Table 4 on page 14 .

NOTE: System performance is optimized when the DIMM type and quantity are equal for both CPUs.

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 15

CONFIGURING the SERVER

Caveats

Do not mix 1333 MHz and 1600 MHz DIMMs

Do not mix DIMM types (RDIMM, LRDIMM, or UDIMM)

Do not select more than two different types of DIMMs (only two PID types allowed)

For 2-CPU configurations, install a minimum of 2 DIMMs (one per CPU).

If you use different sizes of DIMMs, the quantity of each size of DIMM must be even (2, 4, or

6). For example, 4 UCS-MR-1X082RY-A DIMMs and 6 UCS-MR-1X162RY-A DIMMs. Also, the sum of all PIDs must adhere to the maximum quantity rule of 12 DIMMs for 2-CPU systems.

By default, all DIMMs run at 1.35 V, which yields 1333-MHz memory speeds. To run the memory DIMMS at 1600 MHz, you need to go into the BIOS or set the policy with UCSM

(service profile) to run in Performance Mode. This forces the DIMMs to operate at 1.5 V and yields 1600-MHz speeds, provided:

— The DIMMs are 1600-MHz devices

— The CPUs chosen support 1600-MHz operation.

NOTE: 32 GB LRDIMMs run at a maximum speed of 1333 MHz for 1 DPC and 2 DPC even though their specified maximum speed is 1600 MHz.

NOTE: In this server, 4 GB UDIMMs run slower than their specified maximum speed of

1600 MHz. In addition, the following rules apply to UDIMMs:

1 DPC: 1333 MHz is supported at 1.35 V and 1.5 V

2 DPC: 1066 MHz is supported at 1.35 V and 1.5 V

For more information regarding memory, see CPUs and DIMMs, page 49

.

16 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server

CONFIGURING the SERVER

STEP 4 SELECT RAID CONFIGURATION

NOTE: If you do not select a PCIe RAID controller or one of the embedded RAID upgrade options, you will have an embedded SATA-only RAID controller that supports up to four SATA-only drives (RAID 0, 1, 10)

NOTE: When creating a RAID volume, follow these guidelines:

Use the same capacity for each drive in the volume

Use either all SAS drives or all SATA drives

Use either all HDDs or all SSDs

NOTE: The number of RAID groups (virtual drives) supported per controller is as follows (note however, that this server can have a maximum of only eight internal physical drives):

LSI MegaRAID SAS 9270CV-8i RAID controller card = 64

LSI MegaRAID 9240-8i RAID controller card = 16

LSI MegaRAID 9220-8i RAID controller card = 16

The RAID controller choices are:

(1) Embedded RAID (on motherboard)\

NOTE: Embedded RAID is not available with VMWare.

NOTE: The RAID configuration options listed in

Table 6 on page 18

are not available if you choose embedded RAID (in this case, you must configure RAID yourself using separate software).

(2) PCIe RAID controllers

Cisco can provide factory-configured RAID systems depending on the RAID controller chosen and the number of drives ordered. Factory-configured RAID options are listed with each RAID card description.

RAID levels 50 and 60 are supported, although they are not available as factory-configured RAID options.

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 17

CONFIGURING the SERVER

Select RAID Options

Select one RAID controller (either embedded RAID in

Table 5

or hardware RAID using a PCIe RAID controller and an appropriate RAID configuration option listed in

Table 6 on page 18 ).

Table 5 Available Embedded RAID (LSI MegaSR) Options

Product ID (PID)

Embedded RAID

UCSC-RAID-ROM5

PID Description

UCSC-RAID-ROM55

Onboard RAID, consisting of a plug-in storage controller unit (SCU), supporting up to 8 internal SAS +SATA drives. SAS and SATA drives can be mixed. This option supports RAID 0, 1, and 10, and operates at 3 Gb/s. Operating systems supported are Windows and Linux only (no VMware support).

Onboard RAID, consisting of two plug-in modules (an SCU plus a software key module) supporting up to 8 internal SAS+SATA drives. SAS and SATA drives can be mixed. This option supports RAID 0, 1, 5, and 10 and operates at 3 Gb/s.

Operating systems supported are Windows and Linux only (no VMware support).

NOTE: VMware ESX/ESXi or any other virtualized environments are not supported for use with the embedded MegaRAID controller. Hypervisors such as Hyper-V, Xen, or

KVM are also not supported for use with the embedded MegaRAID controller

Table 6 Available Hardware RAID Options

Product ID (PID) PID Description

RAID Controllers

Note that PCIe RAID controllers are installed by default in slot 1 for 1-CPU systems and slot 2 for

2-CPU systems

UCSC-RAID-9240-8I LSI MegaRAID 9240-8i

■ Supports up to 8 internal SAS+SATA drives. SAS and SATA drives can be mixed.

■ RAID levels supported: RAID 0, 1, 5, 10, 50 (see the RAID Configuration

Options section later in this table)

UCSC-RAID-9220-8I LSI MegaRAID 9220-8i

■ Supports up to 8 internal SAS+SATA drives. SAS and SATA drives can be mixed.

■ RAID levels supported: RAID 0, 1, 10 (see the RAID Configuration Options section later in this table)

18 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server

CONFIGURING the SERVER

Table 6 Available Hardware RAID Options (continued)

Product ID (PID) PID Description

UCS-RAID9270CV-8i LSI MegaRAID 9270CV-8i (with supercap power backup)

■ Supports up to 8 internal SAS+SATA drives. SAS and SATA drives can be mixed.

■ Includes a 1 GB Transportable Memory Module (TMM) cache and chassis-mount (remote) supercap power module for data cache backup

■ RAID levels supported: RAID 0, 1, 5, 6, 10, 50, 60 (see the RAID

Configuration Options section later in this table)

RAID Configuration Options (not available for embedded RAID)

R2XX-RAID0 Factory preconfigured RAID striping option

Enable RAID 0 Setting. Requires a minimum of one hard drive.

R2XX-RAID1

R2XX-RAID5

R2XX-RAID6

R2XX-RAID10

Factory preconfigured RAID mirroring option

Enable RAID 1 Setting. Requires exactly two drives with the same size, speed, capacity.

Factory preconfigured RAID option

Enable RAID 5 Setting. Requires a minimum of three drives of the same size, speed, capacity.

Factory preconfigured RAID option

Enable RAID 6 Setting. Requires a minimum of four drives of the same size, speed, capacity.

Factory preconfigured RAID option

Enable RAID 10 Setting. Requires an even number of drives (minimum of four drives) of the same size, speed, capacity.

NOTE: Although RAID levels 50 and 60 are not orderable from the factory, they are supported for selected controllers as shown in

Table 6 .

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 19

CONFIGURING the SERVER

Approved Configurations

(1) 1-CPU Configurations

Select an embedded RAID option from Table 5 on page 18

or one PCIe RAID controller from

Table 6 on page 18 . You may also select an appropriate optional RAID configuration listed in

Table 6 on page 18 .

NOTE: In 1-CPU configurations, PCIe slot 1 is the default slot supported for an internal drive RAID controller. PCIe slot 2 is not supported for 1-CPU systems.

NOTE: If you do not select a PCIe RAID controller or one of the embedded RAID

upgrade options from Table 5 on page 18 , you will have an embedded SATA-only

RAID controller that supports up to four SATA-only drives (RAID 0, 1, 10) and slot 1 can be used for a PCIe RAID controller (see

Table 8 on page 24 ).

(2) 2-CPU Configurations

Select an embedded RAID option from Table 5 on page 18

, or one PCIe RAID controller from

Table 6 on page 18 . You may also select an appropriate optional RAID configuration listed in

Table 6 on page 18 .

NOTE: In 2-CPU configurations, PCIe slot 2 is the default slot supported for an internal drive RAID controller. PCIe slot 1 can be used for a PCIe expansion card

(including the VIC card). You can change the default card slot for a RAID controller to slot 1 by going into the BIOS and reconfiguring the option ROM (OPROM) settings.

Keep in mind, however, that if you use slot 1 for a RAID controller, you will not be able to install a VIC card, which can be installed only in slot 1.

NOTE: If you do not select a PCIe RAID controller, or one of the embedded RAID

upgrade options from Table 5 on page 18 , you will have an embedded SATA-only

RAID controller that supports up to four SATA-only drives (RAID 0, 1, 10) and slots 1 and 2 can be used for PCIe cards (see

Table 8 on page 24 ).

Caveats

■ In 1-CPU configurations, there is only one full-height PCIe slot available (located on riser 1).

Slot 2 is not supported in 1-CPU systems.

— If you choose embedded RAID, you can select one optional PCIe card from

Table 8 on page 24 to be installed in slot 1.

— If you choose a PCIe RAID controller from Table 5 on page 18 , it will be installed in

slot 1 by default and you will not be able to select any optional PCIe card from

Table 8 on page 24 .

20 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server

CONFIGURING the SERVER

— Note that only a single Cisco 1225 Virtual Interface Card (VIC) card is supported and it must be installed in the full-length, full-height PCIe slot (slot 1) on riser 1, which is the only slot that supports NCSI. So take this into account when populating RAID controller cards. You can have either a PCIe RAID controller or a VIC card in slot 1.

— Slot 2 is not supported in 1-CPU systems.

In 2-CPU configurations, there are two PCIe slots available (one full-height slot, slot 1, and one half-height slot, slot 2).

— If you choose embedded RAID, you can select up to two optional PCIe cards from

Table 8 on page 24 to be installed in slots 1 and 2.

— If you choose a PCIe RAID controller from Table 5 on page 18 , it will be installed in

slot 2 by default and you will be able to select one additional optional PCIe card

from Table 8 on page 24

to be installed in slot 1.

The optional PCIe RAID controllers are all half-height. If you choose one of these cards in a

2-CPU configuration, only the full-height PCIe card slot will be available for an additional optional PCIe card.

Note that only a single Cisco UCS 1225 Virtual Interface Card (VIC) card is supported and it must be installed in the full-length, full-height PCIe slot (slot 1) on riser 1, which is the only slot that supports NCSI. So take this into account when populating RAID controller cards.

You can choose only one type of RAID controller, either embedded RAID or a PCIe RAID controller. If you choose embedded RAID, slot 1 in a 1-CPU system and slots 1 and 2 in a

2-CPU system are available for adding optional PCIe cards.

For PCIe RAID controllers, you can choose an optional RAID configuration (RAID 0, 1, 5, 6, or

10), which is preconfigured at the factory. The RAID level you choose must be an available

RAID choice for the controller selected. RAID levels 50 and 60 are supported, depending on the RAID controller selected, although they are not available as configuration options.

NOTE: For more important information regarding RAID support, see

RAID Summary, page 55 and

RAID Option ROM (OPROM) Settings, page 56

.

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 21

CONFIGURING the SERVER

STEP 5 SELECT DRIVES

The standard disk drive features are:

2.5-inch small form factor

Hot-pluggable

Sled-mounted

Select Drives

The available drives are listed in Table 7 .

Table 7 Available Hot-Pluggable Sled-Mounted HDDs or SSDs

Product ID (PID) PID Description

HDDs

UCS-HDD250G1F111

UCS-HDD300GI2F105

A03-D300GA2

A03-D500GC3

A03-D600GA2

UCS-HDD900GI2F106

A03-D1TBSATA

250 GB 6Gb SATA 7.2K RPM

300 GB 6Gb SAS 15K RPM SFF

300 GB 6Gb SAS 10K RPM SFF

500 GB SATA 7.2K RPM SFF

600 GB 6Gb SAS 10K RPM SFF

900 GB 6Gb SAS 10K RPM SFF

1 TB SATA 7.2K RPM SFF

SSDs

UCS-SD200G0KS2-EP

UCS-SD400G0KS2-EP

UCS-SD800G0KS2-EP

200 GB 2.5 inch Enterprise Performance SAS

400 GB 2.5 inch Enterprise Performance SAS

800 GB 2.5 inch Enterprise Performance SAS

UCS-SD480G0KS2-EV 480 GB 2.5 inch Enterprise Value 6 G SATA SSD

UCS-SD240G0KS2-EV

UCS-SD120G0KS2-EV

240 GB 2.5 inch Enterprise Value 6 G SATA SSD

120 GB 2.5 inch Enterprise Value 6 G SATA SSD

UCS-SD100G0KA2-G

UCS-SD400G0KA2-G

100 GB Read SSD

400 GB Read SSD

Drive

Type

Capacity

SATA

SATA

SATA

SATA

SAS

SAS

SAS

SATA

SATA

SAS

SAS

SATA

SAS

SAS

SATA

200 GB

400 GB

800 GB

480 GB

240 GB

120 GB

100 GB

400 GB

250 GB

300 GB

300 GB

500 GB

600 GB

600 GB

1 TB

22 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server

CONFIGURING the SERVER

NOTE: When creating a RAID volume, follow these guidelines:

Use the same capacity for each drive in the volume

Use either all SAS drives or all SATA drives

Use either all HDDs or all SSDs

NOTE: The number of RAID groups (virtual drives) supported per controller is as follows:

LSI MegaRAID SAS 9270CV-8i RAID controller card = 64

LSI MegaRAID 9240-8i RAID controller card = 16

LSI MegaRAID 9220-8i RAID controller card = 16

Approved Configurations

(1) Embedded RAID (LSI MegaSR)

■ Select up to eight SAS/SATA drives (note that none of the RAID configuration options listed in

Table 6 on page 18 can be chosen for embedded RAID). You can mix SAS and SATA drives.

(2) LSI MegaRAID 9270CV-8i (with data cache and supercap), LSI MegaRAID 9240-8i, and LSI

MegaRAID 9220-8i

■ Select up to eight SAS/SATA drives listed in

Table 7 on page 22

. You can mix SAS and SATA drives.

(3) None of the Above

■ If you did not select embedded RAID or a PCIe RAID controller, you can only select up to four

SATA drives, which will be controlled by the embedded SATA-only RAID controller.

Caveats

You can mix SATA and SAS drives

If you select one or more SAS drives, you must select either a PCIe RAID controller from

Table 6 on page 18 or an embedded RAID option from Table 5 on page 18

.

If you select four or less SATA-only drives, you can select a PCIe RAID controller from

Table 6 on page 18 or an embedded RAID option from Table 5 on page 18

, or neither. If you select neither, the drives will be controlled by the embedded SATA-only RAID controller.

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 23

CONFIGURING the SERVER

STEP 6 SELECT PCIe OPTION CARD(s)

The standard PCIe card offerings are:

Converged Network Adapters (CNAs)

Network Interface Cards (NICs)

Host Bus Adapters (HBAs)

Select PCIe Option Cards

The available PCIe option cards are listed in Table 8 .

Table 8 Available PCIe Option Cards

Product ID (PID) PID Description

Converged Network Adapters (CNAs)

UCSC-PCIE-CSC-02 Cisco VIC 1225 Dual Port 10Gb SFP+ CNA

UCSC-PCIE-C10T-02 Cisco VIC 1225T Dual Port 10GBaseT CNA

UCSC-PCIE-C40Q-02 Cisco VIC 1285 Dual Port 40Gb QSFP CNA

UCSC-PCIE-ESFP

UCSC-PCIE-Q8362

Emulex OCe11102-FX dual-port 10 GbE FCoE CNA

Qlogic QLE8362 dual-port 10 GbE FCoE CNA

Network Interface Cards (NICs)

N2XX-ABPCI01-M3 Broadcom 5709 Dual-Port Ethernet PCIe Adapter w/TOE for M3 Servers

N2XX-ABPCI03-M3

UCSC-PCIE-BTG

N2XX-AIPCI01

UCSC-PCIE-IRJ45

Broadcom 5709 Quad Port 10/100/1Gb NIC w/TOE iSCSI for M3 Servers

Broadcom 57712 Dual Port 10GbE 10G-BaseT w/TOE

Intel 10GbE 2-Port Niantec Controller with Copper SFP+ Cable

Intel Quad Port GbE controller (this is a quad-port i350 controller)

UCSC-PCIE-ITG

UCSC-PCIE-B3SFP

Intel X540 Dual Port 10GBase-T Adapter

BROADCOM 57810 10Gb AFEX SFP+

Host Bus Adapters (HBAs)

N2XX-AEPCI03 Emulex LPe 11002, 4Gb Fibre Channel PCIe Dual Channel HBA

N2XX-AEPCI05

N2XX-AQPCI03

N2XX-AQPCI05

UCSC-PCIE-Q2672

UCSC-PCIE-E16002

Emulex LPe 12002, 8Gb dual port Fibre Channel HBA

Qlogic QLE2462, 4Gb dual port Fibre Channel HBA

Qlogic QLE2562, 8Gb dual port Fibre Channel HBA

Qlogic QLE2672-CSC, 16Gb Fibre Channel HBA with SR Optics

Emulex LPe16002-M6, 16Gb Fibre Channel HBA with SR Optics

Card

Height

Half

Half

Half

Half

Half

Half

Half

Half

Half

Half

Half

Half

Half

Half

Half

Half

Half

Half

24 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server

CONFIGURING the SERVER

Approved Configurations

(1) No PCIe RAID controller

■ If you did not choose a PCIe RAID controller (for example, you selected embedded RAID (LSI

MegaSR) or no RAID controller at all), you can select up to one PCIe option card listed in

Table 8 on page 24 for 1-CPU configurations or up to two cards for 2-CPU configurations.

(2) One PCIe RAID controller

■ If you selected a PCIe RAID controller, you cannot select any additional PCIe cards for 1-CPU configurations; however, you can select one additional optional PCIe card for 2-CPU configurations.

NOTE: If a PCIe RAID controller is installed, any optional PCIe card you select will be installed in the full-height slot. RAID controllers are always installed in the half-height slot (unless you change the OPROM setting to enable the full-height slot, slot 1) for RAID.

Caveats

Only a single Cisco UCS 1225 Virtual Interface Card (VIC) card is supported and it must be installed in the full-height slot of riser 1, which is the only slot that supports NCSI.

All PCIe cards will fit in either riser 1 or riser 2, except the VIC card, which must be installed in the full-height slot of riser 1. The Cisco 1225 VIC card must be plugged into slot 1, which supports NCSI.

Additional considerations for the Cisco 1225 VIC card:

— Supports 10G SFP+ optical and copper twinax connections

— The server supports installation of only one Cisco VIC 1225 card and it is supported only in PCIe slot 1. Slot 1 can operate while the server is in standby power mode.

— Requires that the server has CIMC firmware version 1.4(6) or later installed. There is a heartbeat LED on the top of the card that indicates when firmware is active.

— To use this card for UCS integration (Cisco UCS Manager mode) with Cisco UCS

Manager 2.1(0) or later, the minimum card-firmware and uboot image level is

2.1(0.306).

To help ensure that your operating system is compatible with the card you have selected, check the Hardware Compatibility List at this URL: http://www.cisco.com/en/US/products/ps10477/prod_technical_reference_list.html

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 25

CONFIGURING the SERVER

STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES

Copper twinax cables and SFP optical modules may be ordered to support the two-port network cards that are available with the server.

Choose Optional Twinax Cables

Table 9 lists the copper twinax cables available for the PCIe cards. You can choose cable lengths

of 1, 3, 5, 7, or 10 meters. The two longer cables (7 and 10 meters) are active, which means that they contain active components within the SFP+ housing to improve signal quality.

Table 9 Available Twinax Cables

Product ID (PID)

SFP-H10GB-CU1M

SFP-H10GB-CU3M

SFP-H10GB-CU5M

SFP-H10GB-ACU7M

SFP-H10GB-ACU10M

PID Description

10GBASE-CU SFP+ Cable (1 M)

10GBASE-CU SFP+ Cable (3 M)

10GBASE-CU SFP+ Cable (5 M)

10GBASE-CU SFP+ Cable (7 M)

10GBASE-CU SFP+ Cable (10 M)

Approved Configurations

(1) Choose Up to Two Twinax Cables for Each Network Card Ordered

■ You may choose one or two twinax cables for each compatible PCIe network card ordered.

The cables can be different lengths; however, you would normally order two cables of equal lengths to connect to the primary and redundant network switching equipment.

Choose Optional SFP Modules

Optical Cisco SFP+ modules are listed in Table 10 .

Table 10 Available SFP Modules

Product ID (PID)

SFP-10G-SR

DS-SFP-FC8G-SW

PID Description

10GBASE-SR SFP+ Module

850 nm, multimode, SR, 3.3V, LC connector, with Digital Optical Monitoring

8 Gbit SFP+ Module

850 nm, multimode, SR, 3.3V, LC connector, with Digital Optical Monitoring

26 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server

CONFIGURING the SERVER

Approved Configurations

(1) Choose Up to Two SFP+ Modules for Each Network Card Ordered

■ You may choose one or two SFP+ optical modules cables for each compatible PCIe network card ordered. You would normally order two modules for connecting to the primary and redundant network switching equipment. With the SFP+ optical modules, you can use common fiber optic cables, widely available.

See the

Figure 5 on page 29

for typical SFP+ and twinax connections to the network cards.

Caveats

Check the table on the following page for compatibility between the PCIe network cards and

SFPs or twinax cables.

NOTE: The table shows all PCIe network cards for all C-series servers. Not all of the cards shown in the table are supported in this server. The intent of the table is to show compatibility between cards and twinax cables or SFPs.

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 27

CONFIGURING the SERVER

Table 11 PCIe Card Compatibility

PCIe Cards

Converged Network Adapters (CNAs)

UCSC-PCIE-BSFP

(Broadcom 57712 Dual Port 10Gb SFP+ w/TOE iSCSI)

UCSC-PCIE-CSC-02

(Cisco VIC 1225 Dual Port 10Gb SFP+ CNA)

UCSC-PCIE-C10T-02

(Cisco VIC 1225T Dual Port 10GBaseT CNA)

UCSC-PCIE-C40Q-02

(Cisco VIC 1285 Dual Port 40Gb QSFP CNA)

UCSC-PCIE-C40Q-03

(Cisco VIC 1385 Dual Port 40Gb QSFP+ CNA w/RDMA)

UCSC-PCIE-ESFP

(Emulex OCe11102-FX dual-port 10 GbE FCoE CNA (Gen 3 CNA))

UCSC-PCIE-QSFP

(QLogic QLE8242-CU dual-port 10 GbE FCoE CNA)

UCSC-PCIE-B3SFP

(Broadcom 57810 10Gb A-FEX SFP+

UCSC-PCIE-Q8362

(Qlogic QLE8362 dual-port 10 GbE FCoE CNA)

UCSC-PCIE-E14102

(Emulex OCe14102-UX dual-port 10 GbE FCoE CNA)

Network Interface Cards (NICs)

N2XX-ABPCI01-M3

(Broadcom 5709 Dual-Port Ethernet PCIe Adapter for M3

Servers)

N2XX-ABPCI03-M3

(Broadcom 5709 Quad Port 10/100/1Gb NIC w/TOE iSCSI for M3

Servers

N2XX-AIPCI01

(Intel X520 Dual Port 10Gb SFP+ Adapter)

UCSC-PCIE-ITG

(Intel X540 Dual Port 10GBase-T Adapter)

UCSC-PCIE-IRJ45

(Intel i350 Quad Port 1Gb Adapter

UCSC-PCIE-BTG

(Broadcom 57712 Dual Port 10GBASE-T w/TOE iSCSI)

Host Bus Adapters (HBAs)

N2XX-AEPCI03

(Emulex LPe 11002 Dual Port 4Gb Fibre Channel HBA

N2XX-AEPCI05

(Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA)

N2XX-AQPCI03

(QLogic QLE2462 Dual Port 4Gb Fibre Channel HBA)

Twinax

Cables

Cisco SFP Modules

SFP-10G-SR DS-SFP-FC8G-SW

Yes

Yes

No

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

No

No

No

Yes

Yes

No

No

No

Yes

Yes

Yes

No

Use RJ45 Ethernet cable

No

Use RJ45 Ethernet cable

No

1

1

Use Qlogic SFP

Use Qlogic SFP

Use Intel SFP

No

No

No

No

No

No

No

No

No

No

No

Preinstalled - do not change SFP

Preinstalled - do not change SFP

Preinstalled - do not change SFP

28 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server

CONFIGURING the SERVER

Table 11 PCIe Card Compatibility (continued)

PCIe Cards

N2XX-AQPCI05

(QLogic QLE2562 Dual Port 8Gb Fibre Channel HBA)

UCSC-PCIE-Q2672

(Qlogic QLE2672-CSC, 16Gb Fibre Channel HBA with SR Optics)

UCSC-PCIE-E16002

(Emulex LPe16002-M6, 16Gb Fibre Channel HBA with SR Optics)

Notes . . .

1. This card supports a 4x10 Gbps QSFP to SFP breakout fiber cable.

Twinax

Cables

Cisco SFP Modules

SFP-10G-SR DS-SFP-FC8G-SW

No Preinstalled - do not change SFP

No

No

Preinstalled - do not change SFP

Preinstalled - do not change SFP

Figure 5 Network Card Connections

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 29

CONFIGURING the SERVER

STEP 8 SELECT AC POWER CORD(s)

Using Table 12 , select the appropriate AC power cords. You can select a minimum of no power

cords and a maximum of two. If you select the option R2XX-DMYMPWRCORD, no power cord is shipped with the server.

Table 12 Available Power Cords

Product ID (PID) PID Description

R2XX-DMYMPWRCORD No power cord (dummy PID to allow for a no power cord option)

CAB-N5K6A-NA Power Cord, 200/240V 6A, North

America

Images

Not applicable

Plug: NEMA 6-15P

Cordset rating: 10 A, 250 V

Length: 8.2 ft

Connector:

IEC60320/C13

CAB-AC-L620-C13 AC Power Cord, NEMA L6-20 - C13,

2M/6.5ft

CAB-C13-CBN CABASY,WIRE,JUMPER CORD, 27" L,

C13/C14, 10A/250V

CAB-C13-C14-2M CABASY,WIRE,JUMPER CORD,PWR,

2 Meter, C13/C14, 10A/250V

CAB-C13-C14-AC CORD,PWR,JMP,IEC60320/C14,IEC6

0320/C13, 3.0M

30 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server

CONFIGURING the SERVER

Table 12 Available Power Cords

Product ID (PID)

SFS-250V-10A-AR

CAB-9K10A-AU

PID Description

Power Cord, SFS, 250V, 10A,

Argentina

Power Cord, 250VAC 10A 3112 Plug,

Australia

Images

Plug:

EL 219

(IRAM 2073)

2500 mm

Cordset rating: 10 A, 250/500 V MAX

Length: 8.2 ft

Connector:

EL 701

(IEC60320/C13)

Plug:

EL 210

Cordset rating: 10 A, 250 V/500 V MAX

Length: 2500mm

Connector:

EL 701C

(EN 60320/C15)

(BS 1363A) 13 AMP fuse

SFS-250V-10A-CN Power Cord, SFS, 250V, 10A, China

Plug:

EL 218

(CCEE GB2009)

Cordset rating 10A, 250V

(2500 mm)

Connector:

EL 701

(IEC60320/C13)

CAB-250V-10A-CN AC Power Cord - 250V, 10A - PRC

CAB-9K10A-EU

SFS-250V-10A-ID

SFS-250V-10A-IS

Power Cord, 250VAC 10A CEE 7/7

Plug, EU

Power Cord, SFS, 250V, 10A, India

Plug:

EL 208

Power Cord, SFS, 250V, 10A, Israel

EL-212

16A

250V

Plug:

EL 212

(SI-32)

Plug:

M2511

Cordset rating: 10A/16 A, 250 V

Length: 8 ft 2 in. (2.5 m)

Connector:

VSCC15

Cordset rating 16A, 250V

(2500mm)

Connector:

EL 701

Cordset rating 10A, 250V/500V MAX

(2500 mm)

Connector:

EL 701B

(IEC60320/C13)

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 31

CONFIGURING the SERVER

Table 12 Available Power Cords

Product ID (PID)

CAB-9K10A-IT

PID Description

Power Cord, 250VAC 10A CEI

23-16/VII Plug, Italy

CAB-9K10A-SW

CAB-9K10A-UK

CAB-9K12A-NA

CAB-250V-10A-BR

CAB-JPN-3PIN

Images

Plug:

I/3G

(CEI 23-16)

Cordset rating: 10 A, 250 V

Length: 8 ft 2 in. (2.5 m)

Connector

C15M

(EN60320/C15 )

Power Cord, 250VAC 10A MP232

Plug, Switzerland

Plug:

MP232-R

Cordset rating: 10 A, 250 V

Length: 8 ft. 2 in (2.5 m)

Connector:

IEC 60320 C15

Power Cord, 250VAC 10A BS1363

Plug (13 A fuse), UK

Plug:

EL 210

Cordset rating: 10 A, 250 V/500 V MAX

Length: 2500mm

Connector:

EL 701C

(EN 60320/C15)

(BS 1363A) 13 AMP fuse

Power Cord, 125VAC 13A NEMA

5-15 Plug, North America

Power Cord - 250V, 10A - Brazil

Power Cord 3PIN, Japan

Cordset rating 13A, 125V

(8.2 feet) (2.5m)

Plug:

NEMA 5-15P

1

76.2 From Plug End

2,133.6 ± 25

Image not available

Connector:

IEC60320/C15

32 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server

CONFIGURING the SERVER

STEP 9 ORDER POWER SUPPLY

The C22 M3 server accommodates one power supply. A lightly loaded server can operate from one 450 W power supply. A fully loaded server might need to be powered with a 650 W power supply (see

Table 13

).

Prior to making a power supply selection, the UCS Power Calculator should be run to determine the right size power supply for your server configuration. A fully configured C22 M3 server may require the 650 W power supply. The UCS Power Calculator can be found at the following link: https://mainstayadvisor.com/Go/Cisco/Cisco-UCS-Power-Calculator.aspx

Table 13 Power Supply PIDs

Product ID (PID)

UCSC-PSU-450W

PID Description

450 W power supply

UCSC-PSU-650W 650 W power supply

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 33

CONFIGURING the SERVER

STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM

The reversible cable management arm mounts on either the right or left slide rails at the rear of the server and is used for cable management. Use

Table 14

to order a cable management arm.

Table 14 Cable Management Arm

Product ID (PID)

UCSC-CMA1

PID Description

Cable Management Arm for C22 rack servers

NOTE: If you order and install a cable management arm, you will need the longest power cable available.

For more information about the cable management arm, see the Cisco UCS C22 M3 Installation

and Service Guide at this URL: http://www.cisco.com/en/US/docs/unified_computing/ucs/c/hw/C22/install/C22.pdf

34 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server

CONFIGURING the SERVER

STEP 11 ORDER A TRUSTED PLATFORM MODULE

Trusted Platform Module (TPM) is a computer chip (microcontroller) that can securely store artifacts used to authenticate the platform (server). These artifacts can include passwords, certificates, or encryption keys. A TPM can also be used to store platform measurements that help ensure that the platform remains trustworthy. Authentication (ensuring that the platform can prove that it is what it claims to be) and attestation (a process helping to prove that a platform is trustworthy and has not been breached) are necessary steps to ensure safer computing in all environments.

The TPM ordering information is listed in Table 15 .

Table 15 Trusted Platform Module

Product ID (PID)

UCSX-TPM1-001

PID Description

Trusted Platform Module

NOTE: The module used in this server conforms to TPM v1.2/1.3, as defined by the

Trusted Computing Group (TCG). It is also SPI-based.

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 35

CONFIGURING the SERVER

STEP 12 ORDER OPTIONAL USB 2.0 DRIVE

You may order one optional USB 2.0 drive. One socket on the motherboard can accommodate an

8 or 16 GB drive.

The 8 or 16 GB drive (if ordered) is blank and comes installed on the motherboard. It can be used for a hypervisor or a license dongle.

The USB drive ordering information is listed in Table 16 .

Table 16 USB 2.0 Drive

Product ID (PID)

UCS-USBFLSHA-8GB

UCS-USBFLSHB-16GB

PID Description

8 GB Flash USB Drive for C22/C24

UCS Servers 16GB Flash USB Drive

See Figure 6 on page 48 for the location of the internal USB connector.

36 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server

CONFIGURING the SERVER

STEP 13 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE

Several operating systems and value-added software programs are available. Select as desired

from Table 17 .

Table 17 OSs and Value-Added Software (for 2-CPU servers)

PID Description Product ID (PID)

Microsoft Windows Server

MSWS-08R2-STHV Windows Svr 2008 ST media R2 ST (1-4CPU, 5CAL)

MSWS-08R2-ENHV

MSWS-08R2-DCHV2S

Windows Svr 2008 EN media R2 EN (1-8CPU, 25CAL)

Windows Svr 2008 R2-2 CPU-Data Center

MSWS-12-ST2S

MSWS-12-DC2S

MSWS-12-ST2S-NS

MSWS-12-DC2S-NS

Windows Server 2012 Standard (2 CPU/2 VMs)

Windows Server 2012 Datacenter (2 CPU/Unlimited VMs)

Windows Server 2012 Standard (2 CPU/2 VMs) No Cisco SVC

Windows Server 2012 Datacenter (2 CPU/Unlim VM) No Cisco SVC

MSWS-12R2-ST2S

MSWS-12R2-DC2S

MSWS-12R2-ST2S-NS

MSWS-12R2-DC2S-NS

SUSE

SLES-SVR-2S-1G-1A

Windows Server 2012 R2 Standard (2 CPU/2 VMs)

Windows Server 2012 R2 Datacenter (2 CPU/Unlimited VMs)

Windows Server 2012 R2 Standard (2 CPU/2 VMs) No Cisco SVC

Windows Server 2012 R2 Datacen (2 CPU/Unlim VM) No Cisco Svc

SUSE Linux Enterprise Srvr (1-2 CPU,1 Phys);1yr Support Reqd

SLES-SVR-2S-1G-3A

SLES-SVR-2S-1G-5A

SLES-SVR-2S-UG-1A

SLES-SVR-2S-UG-3A

SLES-SVR-2S-UG-5A

SLES-SHA-2S-1A

SLES-SHA-2S-3A

SUSE Linux Enterprise Srvr (1-2 CPU,1 Phys);3yr Support Reqd

SUSE Linux Enterprise Srvr (1-2 CPU,1 Phys);5yr Support Reqd

SUSE Linux Enterprise Svr (1-2 CPU,Unl Vrt);1yr Support Reqd

SUSE Linux Enterprise Svr (1-2 CPU,Unl Vrt);3yr Support Reqd

SUSE Linux Enterprise Svr (1-2 CPU,Unl Vrt);5yr Support Reqd

SUSE Linux High Availability Ext (1-2 CPU); 1yr Support Reqd

SUSE Linux High Availability Ext (1-2 CPU); 3yr Support Reqd

SLES-SHA-2S-5A

SLES-HGC-2S-1A

SLES-HGC-2S-3A

SLES-HGC-2S-5A

SLES-SAP-2S-1G-1A

SLES-SAP-2S-1G-3A

SLES-SAP-2S-1G-5A

SLES-SAP-2S-UG-1A

SLES-SAP-2S-UG-3A

SLES-SAP-2S-UG-5A

SUSE Linux High Availability Ext (1-2 CPU); 5yr Support Reqd

SUSE Linux GEO Clustering for HA (1-2 CPU); 1yr Support Reqd

SUSE Linux GEO Clustering for HA (1-2 CPU); 3yr Support Reqd

SUSE Linux GEO Clustering for HA (1-2 CPU); 5yr Support Reqd

SLES for SAP Applications (1-2 CPU,1 Phys); 1yr Support Reqd

SLES for SAP Applications (1-2 CPU,1 Phys); 3yr Support Reqd

SLES for SAP Applications (1-2 CPU,1 Phys); 5yr Support Reqd

SLES for SAP Applications (1-2 CPU,Unl Vrt);1yr Support Reqd

SLES for SAP Applications (1-2 CPU,Unl Vrt);3yr Support Reqd

SLES for SAP Applications (1-2 CPU,Unl Vrt);5yr Support Reqd

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 37

CONFIGURING the SERVER

Table 17 OSs and Value-Added Software (for 2-CPU servers) (continued)

PID Description Product ID (PID)

Red Hat Enterprise Linux

RHEL-2S-1G-1A RHEL/2 Socket/1 Guest/1Yr Svcs Required

RHEL-2S-1G-3A RHEL/2 Socket/1 Guest/3Yr Svcs Required

RHEL-2S-4G-1A

RHEL-2S-4G-3A

RHEL/2 Socket/4 Guest/1Yr Svcs Required

RHEL/2 Socket/4 Guest/3Yr Svcs Required

RHEL-2S-UG-1A

RHEL-2S-UG-3A

RHEL-HA-2S-1A

RHEL-HA-2S-3A

RHEL-RS-2S-1A

RHEL/2 Socket/U Guest/1Yr Svcs Required

RHEL/2 Socket/U Guest/3Yr Svcs Required

RHEL Option/High-Availability/2 Socket/1Yr Svcs Required 

RHEL Option/High-Availability/2 Socket/3Yr Svcs Required 

RHEL Option/Resilient w/Ha /2 Socket/1 Yr Svcs Required 

RHEL-RS-2S-3A

RHEL-SFS-2S-1A

RHEL-SFS-2S-3A

RHEL Option/Resilient Storage w/ HA /2 Socket/3 Yr Svcs Reqd 

RHEL Option/Scalable File System/2 Socket/1 Yr Svcs Required  

RHEL Option/Scalable File System/2 Socket/1 Yr Svcs Required

BMC

BMC-012

BMC-SE-4C

BMC-SE-6C

BMC-SE-8C

BMC-SE-10C

BMC-AE-4C

BMC BPPM Per Server 

BMC BladeLogic Standard Edition, 4 Cores, Support Required

BMC BladeLogic Standard Edition, 6 Cores, Support Required

BMC BladeLogic Standard Edition, 8 Cores, Support Required

BMC BladeLogic Standard Edition, 10 Cores, Support Required

BMC BladeLogic Advanced Edition, 4 Cores, Support Required

BMC-AE-6C

BMC-AE-8C

BMC BladeLogic Advanced Edition, 6 Cores, Support Required

BMC BladeLogic Advanced Edition, 8 Cores, Support Required

BMC-AE-10C BMC BladeLogic Standard Edition, 10 Cores, Support Required

Nexus 1000V for Hyper-V and vSphere

N1K-VSG-UCS-BUN Over half off N1K and VSG w/ purchase of UCS B/C Series

N1K-VLEM-UCS-1

VSG-VLEM-UCS-1

UCS Director

CUIC-PHY-SERV-BM-U

Nexus 1000V License Paper Delivery (1 CPU) for bundles

VSG License Paper Delivery (1 CPU) for bundles

CUIC-PHY-SERV-U

CUIC-TERM

Cisco Cloupia Resource Lic - One Phy Server node bare metal

Cisco Cloupia Resource Lic - One physical Server node

Acceptance of Cisco Cloupia License Terms

38 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server

CONFIGURING the SERVER

Table 17 OSs and Value-Added Software (for 2-CPU servers) (continued)

PID Description

VMware 5

VMW-VS5-STD-1A

VMW-VS5-STD-2A

VMW-VS5-STD-3A

VMW-VS5-STD-4A

VMW-VS5-STD-5A

VMW-VS5-ENT-1A

VMW-VS5-ENT-2A

VMW-VS5-ENT-3A

VMW-VS5-ENT-4A

VMW-VS5-ENT-5A

VMW-VS5-ENTP-1A

VMW-VS5-ENTP-2A

VMW-VS5-ENTP-3A

VMW-VS5-ENTP-4A

VMW-VS5-ENTP-5A

VMW-VC5-STD-1A

VMW-VC5-STD-2A

VMW-VC5-STD-3A

VMW-VC5-STD-4A

VMW-VC5-STD-5A

UCS-VMW-TERMS

Product ID (PID)

VMware vSphere 5 Standard for 1 Processor, 1 Year, Support Rqd

VMware vSphere 5 Standard for 1 Processor, 2 Year, Support Rqd

VMware vSphere 5 Standard for 1 Processor, 3 Year, Support Rqd

VMware vSphere 5 Standard for 1 Processor, 4 Year, Support Rqd

VMware vSphere 5 Standard for 1 Processor, 5 Year, Support Rqd

VMware vSphere 5 Enterprise for 1 Processor, 1 Year Support Rqd

VMware vSphere 5 Enterprise for 1 CPU, 2 Yr Support Rqd

VMware vSphere 5 Enterprise for 1 CPU, 3 Yr Support Rqd

VMware vSphere 5 Enterprise for 1 Processor, 4 Year Support Rqd

VMware vSphere 5 Enterprise for 1 CPU, 5 Yr Support Rqd

VMware vSphere 5 Enterprise Plus for 1 Processor, 1 Year Support Rqd

VMware vSphere 5 Enterprise Plus for 1 CPU, 2 Yr Support Rqd

VMware vSphere 5 Enterprise Plus for 1 Processor, 3 Year Support Rqd

VMware vSphere 5 Enterprise Plus for 1 Processor, 4 Year Support Rqd

VMware vSphere 5 Enterprise Plus for 1 Processor, 5 Year Support Rqd

VMware vCenter 5 Server Standard, 1 yr support required 

VMware vCenter 5 Server Standard, 2 yr support required 

VMware vCenter 5 Server Standard, 3 yr support required 

VMware vCenter 5 Server Standard, 4 yr support required 

VMware vCenter 5 Server Standard, 5 yr support required 

Acceptance of Terms, Standalone VMW License for UCS Servers 

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 39

CONFIGURING the SERVER

STEP 14 SELECT OPERATING SYSTEM MEDIA KIT

Select the optional operating system media listed in

Table 18

.

Table 18 OS Media

Product ID (PID)

RHEL-6

SLES-11

MSWS-08R2-STHV-RM

MSWS-08R2-ENHV-RM

MSWS-08R2-DCHV-RM

MSWS-12-ST2S-RM

MSWS-12-DC2S-RM

MSWS-12R2-ST2S-RM

MSWS-12R2-DC2S-RM

PID Description

RHEL 6 Recovery Media Only (Multilingual)

SLES 11 media only (multilingual)

Windows Svr 2008 R2 ST (1-4CPU, 5CAL), Media

Windows Svr 2008 R2 EN (1-8CPU, 25CAL), Media

Windows Svr 2008 R2 DC (1-8CPU, 25CAL), Media

Windows Server 2012 Standard (2 CPU/2 VMs) Recovery Media

Windows Server 2012 Datacenter (2 CPU/Unlimited VM) Rec Media

Windows Server 2012 R2 Standard (2 CPU/2 VMs) Recovery Media

Windows Server 2012 R2 Datacen(2 CPU/Unlimited VM) Rec Media

40 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server

CONFIGURING the SERVER

STEP 15 SELECT SERVICE and SUPPORT LEVEL

A variety of service options are available, as described in this section.

Unified Computing Warranty, No Contract

If you have noncritical implementations and choose to have no service contract, the following coverage is supplied:

Three-year parts coverage.

Next business day (NBD) onsite parts replacement eight hours a day, five days a week.

90-day software warranty on media.

Ongoing downloads of BIOS, drivers, and firmware updates.

UCSM updates for systems with Unified Computing System Manager. These updates include minor enhancements and bug fixes that are designed to maintain the compliance of UCSM with published specifications, release notes, and industry standards.

SMARTnet for UCS

For support of the entire Unified Computing System, Cisco offers the Cisco SMARTnet for UCS

Service. This service provides expert software and hardware support to help sustain performance and high availability of the unified computing environment. Access to Cisco

Technical Assistance Center (TAC) is provided around the clock, from anywhere in the world.

For UCS blade servers, there is Smart Call Home, which provides proactive, embedded diagnostics and real-time alerts. For systems that include Unified Computing System Manager, the support service includes downloads of UCSM upgrades. The Cisco SMARTnet for UCS Service includes flexible hardware replacement options, including replacement in as little as two hours.

There is also access to Cisco's extensive online technical resources to help maintain optimal efficiency and uptime of the unified computing environment. You can choose a desired service listed in

Table 19

.

Table 19 Cisco SMARTnet for UCS Service

Product ID (PID)

CON-PREM-C22M3S

CON-OSP-C22M3S

CON-OSE-C22M3S

CON-OS-C22M3S

CON-S2P-C22M3S

CON-SNTP-C22M3S

CON-SNTE-C22M3S

CON-SNT-C22M3S

On Site? Description

Yes

No

No

Yes

Yes

Yes

No

No

ONSITE 24X7X2 UCS C22 M3 Server - SFF

ONSITE 24X7X4 UCS C22 M3 Server - SFF

ONSITE 8X5X4 UCS C22 M3 Server - SFF

ONSITE 8X5XNBD UCS C22 M3 Server - SFF

SMARTNET 24X7X2 UCS C22 M3 Server - SFF

SMARTNET 24X7X4 UCS C22 M3 Server - SFF

SMARTNET 8X5X4 UCS C22 M3 Server - SFF

SMARTNET 8X5XNBD UCS C22 M3 Server - SFF

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 41

CONFIGURING the SERVER

SMARTnet for UCS Hardware Only Service

For faster parts replacement than is provided with the standard Cisco Unified Computing System warranty, Cisco offers the Cisco SMARTnet for UCS Hardware Only Service. You can choose from two levels of advanced onsite parts replacement coverage in as little as four hours. SMARTnet for UCS Hardware Only Service provides remote access any time to Cisco support professionals who can determine if a return materials authorization (RMA) is required. You can choose a service listed in

Table 20 .

Table 20 SMARTnet for UCS Hardware Only Service

Product ID (PID)

CON-UCW7-C22M3S

CON-UCW5-C22M3S

Service

Level GSP

UCW7

UCW5

On

Site?

Yes

Yes

Description

UC PLUS 24X7X4OS UCS C22 M3 Server - SFF

UC PLUS 8X5XNBDOS UCS C22 M3 Server - SFF

Unified Computing Partner Support Service

Cisco Partner Support Service (PSS) is a Cisco Collaborative Services service offering that is designed for partners to deliver their own branded support and managed services to enterprise customers. Cisco PSS provides partners with access to Cisco's support infrastructure and assets to help them:

Expand their service portfolios to support the most complex network environments

Lower delivery costs

Deliver services that increase customer loyalty

Partner Unified Computing Support Options enable eligible Cisco partners to develop and consistently deliver high-value technical support that capitalizes on Cisco intellectual assets.

This helps partners to realize higher margins and expand their practice.

PSS is available to all Cisco PSS partners, but requires additional specializations and requirements. For additional information, see the following URL: www.cisco.com/go/partnerucssupport

The two Partner Unified Computing Support Options include:

Partner Support Service for UCS

Partner Support Service for UCS Hardware Only

Partner Support Service for UCS provides hardware and software support, including triage support for third party software, backed by Cisco technical resources and level three support.

42 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server

CONFIGURING the SERVER

See Table 21

.

Table 21 Partner Support Service for UCS

Product ID (PID)

CON-PSJ1-C22M3S

CON-PSJ2-C22M3S

CON-PSJ3-C22M3S

CON-PSJ4-C22M3S

Service

Level GSP

PSJ1

PSJ2

PSJ3

PSJ4

On

Site?

No

No

No

No

Description

UCS SUPP PSS 8X5XNBD UCS C22 M3 Server - SFF

UCS SUPP PSS 8X5X4 UCS C22 M3 Server - SFF

UCS SUPP PSS 24X7X4 UCS C22 M3 Server - SFF

UCS SUPP PSS 24X7X2 UCS C22 M3 Server - SFF

Partner Support Service for UCS Hardware Only provides customers with replacement parts in as

little as two hours. See Table 22

.

Table 22 Partner Support Service for UCS (Hardware Only)

Product ID (PID)

CON-PSW2-C22M3S

CON-PSW3-C22M3S

CON-PSW4-C22M3S

Service

Level GSP

PSW2

PSW3

PSW4

On

Site?

No

No

No

Description

UCS W PL PSS 8X5X4 UCS C22 M3 Server - SFF

UCS W PL PSS 24X7X4 UCS C22 M3 Server - SFF

UCS W PL PSS 24X7X2 UCS C22 M3 Server - SFF

Unified Computing Combined Support Service

Combined Services makes it easier to purchase and manage required services under one contract. SMARTnet services for UCS help increase the availability of your vital data center infrastructure and realize the most value from your unified computing investment. The more benefits you realize from the Cisco Unified Computing System (Cisco UCS), the more important the technology becomes to your business. These services allow you to:

Optimize the uptime, performance, and efficiency of your UCS

Protect your vital business applications by rapidly identifying and addressing issues

Strengthen in-house expertise through knowledge transfer and mentoring

Improve operational efficiency by allowing UCS experts to augment your internal staff resources

Enhance business agility by diagnosing potential issues before they affect your operations

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 43

CONFIGURING the SERVER

You can choose a service listed in

Table 23

.

Table 23 UCS Computing Combined Support Service

Product ID (PID)

Service

Level GSP

On

Site?

Description

CON-NCF2C22M3S

CON-NCF2PC22M3S

NCF2

NCF2P

CON-NCF4PC22M3S NCF4P

CON-NCF4SC22M3S NCF4S

CON-NCFCSC22M3S NCFCS

CON-NCFEC22M3S NCFE

CON-NCFPC22M3S NCFP

CON-NCFTC22M3S NCFT

Yes

No

No

No

No

Yes

Yes

Yes

CMB SPT SVC 24X7X2 UCS C22 M3 Server - SFF

CMB SPT SVC 24X7X2OS

UCS C22 M3 Server - SFF

CMB SPT SVC 24X7X4OS

UCS C22 M3 Server - SFF

CMB SPT SVC 8X5X4OS

UCS C22 M3 Server - SFF

CMB SPT SVC 8X5XNBDOS

UCS C22 M3 Server - SFF

CMB SPT SVC 8X5X4

UCS C22 M3 Server - SFF

CMB SPT SVC 24X7X4 UCS C22 M3 Server - SFF

CMB SPT SVC 8X5XNBD

UCS C22 M3 Server - SFF

Unified Computing Drive Retention Service

With the Cisco Unified Computing Drive Retention (UCDR) Service, you can obtain a new disk drive in exchange for a faulty drive without returning the faulty drive. In exchange for a Cisco replacement drive, you provide a signed Certificate of Destruction (CoD) confirming that the drive has been removed from the system listed, is no longer in service, and has been destroyed.

Sophisticated data recovery techniques have made classified, proprietary, and confidential information vulnerable, even on malfunctioning disk drives. The UCDR service enables you to retain your drives and ensures that the sensitive data on those drives is not compromised, which reduces the risk of any potential liabilities. This service also enables you to comply with regulatory, local, and federal requirements.

If your company has a need to control confidential, classified, sensitive, or proprietary data, you

might want to consider one of the Drive Retention Services listed in Table 24 .

NOTE: Cisco does not offer a certified drive destruction service as part of this service.

Table 24 Drive Retention Service Options

Service Description

Service

Program Name

SMARTnet for UCS

Service with Drive

Retention

UCS DR

Service

Level GSP

UCSD7

UCSD7

Service Level

24x7x4 Onsite

8x5xNBD Onsite

Product ID (PID)

CON-UCSD7-C22M3S

CON-UCSD5-C22M3S

44 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server

CONFIGURING the SERVER

Table 24 Drive Retention Service Options (continued)

Service Description

SMARTnet for UCS

HW ONLY+Drive

Retention

Service

Program Name

UCS HW+DR

Service

Level GSP

UCWD7

UCWD5

Service Level

24x7x4 Onsite

8x5xNBD Onsite

Product ID (PID)

CON-UCWD7-C22M3S

CON-UCWD5-C22M3S

For more service and support information, see the following URL: http://www.cisco.com/en/US/services/ps2961/ps10312/Unified_Computing_Services_Overview.pdf

For a complete listing of available services for Cisco Unified Computing System, see this URL: http://www.cisco.com/en/US/products/ps10312/serv_group_home.html

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 45

OPTIONAL STEP - ORDER RACK(s)

OPTIONAL STEP - ORDER RACK(s)

The optional R42610 rack is available from Cisco for the C-Series servers, including the C22 M3

SFF server. This rack is a standard 19-inch rack and can be ordered with a variety of options, as listed in

Table 25

. Racks are shipped separately from the C22 M3 SFF server.

Table 25 Racks and Rack Options

Product ID (PID)

RACK-UCS 1

PID Description

Cisco R42610 expansion rack, no side panels

RACK-UCS2 1

RACK-BLANK-001

Cisco R42610 standard rack, w/side panels

Filler panels (qty 12), 1U, plastic, toolless

RACK-CBLMGT-001

RACK-CBLMGT-011

RACK-FASTEN-001

RACK-FASTEN-002

RACK-JOIN-001

Cable mgt D rings (qty 10), metal

Cable mgt straps (qty 10), Velcro

Mounting screws (qty 100), M6

Cage nuts (qty 50), M6

Rack joining kit

Notes . . .

1. Use these same base PIDs to order spare racks (available only as next-day replacements).

For more information about the R42610 rack, see RACKS, page 57 .

46 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server

OPTIONAL STEP - ORDER PDU

OPTIONAL STEP - ORDER PDU

An optional power distribution unit (PDU) is available from Cisco for the C-Series rack servers, including theC22 M3 server. This PDU is available in a zero rack unit (RU) style (see

Table 25

).

Table 26 PDU Options

Product ID (PID)

RP208-30-2P-U-2

PID Description

Zero RU PDU

For more information about the PDU, see PDUs, page 59 .

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 47

SUPPLEMENTAL MATERIAL

SUPPLEMENTAL MATERIAL

CHASSIS

Figure 6

An internal view of the C22 M3 chassis with the top cover removed is shown in

Figure 6

.

C22 M3 SFF With Top Cover Off

2 3 4 5 6 7

1

SYS FAN1

SYS FAN2

SYS FAN3

SYS FAN4

SYS FAN5

CPU 1

CPU 2

PCIe 1

PCIe 2

PSU 1

12

16 15

14

13

1

2

3

4

Drives

(hot-swappable, accessed through front panel)

Front panel operations board

Drive backplane

9

10

11

Cooling fans (five)

RTC battery on motherboard

12

PCIe riser 2 (PCIe slot 2)

Trusted platform module socket on motherboard (not visible under PCIe riser 2)

Power supply

(accessed through rear panel)

9

8

11

10

48 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server

SUPPLEMENTAL MATERIAL

5 DIMM slots on motherboard (12)

6 CPU and heatsinks (2)

7 PCIe riser 1 (PCIe slot 1)

8 Internal USB 2.0 port

(on motherboard under PCIe riser 1)

13

14

15

16

Integrated SAS RAID connectors on motherboard

(left to right, SCU_Port 0, SCU_Port 1)

Software RAID 5 key header on motherboard

RAID SCU option ROM header on motherboard

Mounting point for SuperCap power module

(RAID backup unit)

CPUs and DIMMs

Physical Layout

Each CPU has three DIMM channels:

CPU1 has channels A, B, and C

CPU2 has channels D, E, and F

Each DIMM channel has two banks: Bank 1 and Bank 2. The blue-colored DIMM banks are for Bank 1 and the black-colored are for Bank 2.

As an example, DIMM slots A1, B1, and C1 belong to Bank 1, while A2, B2, and C2 belong to Bank 2.

Figure 7 shows how banks and channels are physically laid out on the motherboard. The DIMM slots on the

top (channels A, B, and C) are associated with CPU 1, while the DIMM slots on the bottom (channels D, E, and F) are associated with CPU 2. Bank 1 slots (blue) are populated before Bank 2 slots (black).

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 49

SUPPLEMENTAL MATERIAL

Figure 7 Physical Layout of CPU DIMM Channels and Banks

A1

A2

B1

B2

C1

C2

CPU1

D1

D2

E1

E2

F1

F2

CPU2

50 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server

SUPPLEMENTAL MATERIAL

Memory Population Rules

When considering the memory configuration of your server, you should consider the following items:

Each channel has two DIMM slots (for example, channel A = slots A1 and A2).

— Each channel can operate with one or two DIMMs installed.

— If a channel has only one DIMM, populate slot 1 first (the blue slot).

When both CPUs are installed, populate the DIMM slots of each CPU identically.

— Fill blue slots in the channels first: A1, D1, B1, E1, C1, F1

— Fill black slots in the channels second: A2, D2, B2, E2, C2, F2

Any DIMM installed in a DIMM socket for which the CPU is absent is not recognized.

For optimum performance, populate at least one DIMM per memory channel per CPU.

When populating DIMM slots, multiples of 6 DIMMs are best for achieving optimum performance, since there are 3 memory channels per CPU socket and 2 CPUs must be populated.

At 1 DPC and 2 DPC, 1600-MHz DIMMS will run at 1600 MHz (provided the CPU supports 1600

MHz DIMMs) and 1333-MHz DIMMs will run at 1333 MHz.

When mixing DIMMs, the following rules need to be followed:

— When mixing DIMMs of different densities (sizes), populate DIMMs with the highest density first. For example, if you have to mix 16 GB with 8 GB DIMMs, populate 16

GB DIMMs in blue slots (or bank 1) and then 8 GB in black slots (or bank 2).

— When mixing DIMMs with different ranks, populate DIMMs with the higher rank first.

For example, populate 16 GB 2R or 8 GB 2R before 4 GB 1R DIMMs.

— DIMMs of different sizes (4 GB, 8 GB, 16 GB) can be mixed within a channel. Total memory size in each single channel should be the same. For example, if you are mixing 4 GB and 8 GB DIMMs to achieve total 72 GB (6x8 GB + 6x4 GB) for a server, then populate blue slots with 8 GB DIMMs and black slots with 4 GB DIMMs and total memory size should be 12 GB for each of the 3 channels for both CPUs.

— When mixing DIMMs, all the DIMMs in the server must be the same speed.

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 51

SUPPLEMENTAL MATERIAL

Recommended Memory Population

This section explains the recommended DIMM population order rules for the C22 M3 server.

All DIMMs must be DDR3 DIMMs.

Mixing of Registered and Unbuffered DIMMs is not allowed per platform.

Do not mix 1333-MHz DIMMs with 1600-MHz DIMMs.

Follow Table 27

when populating DIMMs in the server.

Table 27 Recommended DIMM Population

CPU 1

Total

Memory

Size

48 GB 1

Blue Slots

Bank 1

(A1, B1, C1)

3 x 4 GB

Black Slots

Bank 2

(A2, B2, C2)

3 x 4 GB

3 x 8 GB —

72 GB 3 x 8 GB 3 x 4 GB

96 GB 2

120 GB

144 GB

192 GB

384 GB

3 x 8 GB

3 x 16 GB

3 x 16 GB

3 x 16 GB

3 x 16 GB

3 x 32 GB

3 x 8 GB

3 x 4 GB

3 x 8 GB

3 x 16 GB

3 x 32 GB

Blue Slots

Bank 1

(D1, E1, F1)

3 x 4 GB

CPU 2

Black Slots

Bank 2

(D2, E2, F2)

3 x 4 GB

3 x 8 GB

3 x 8 GB

3 x 8 GB

3 x 16 GB

3 x 16 GB

3 x 16 GB

3 x 16 GB

3 x 32 GB

3 x 4 GB

3 x 8 GB

3 x 4 GB

3 x 8 GB

3 x 16 GB

3 x 32 GB

Total DIMMs in

System

6

12

12

12

6

12

12

12

12

Notes . . .

1. For 48 GB, there are two possible sweet spot configurations:

6 x 8 GB occupies 1 DPC, so there is a possibility of increasing total memory size in the system (beyond 48 GB) by going to 2 DPC while still maintaining memory speed at 1600 MHz.

If there is no plan to increase total memory size in the system (beyond 48 GB), then 12 x 4GB is more price effective at this time.

2. For 96 GB, there are two possible optimal configurations:

6 x 16GB occupies 1 DPC, so there is a possibility of increasing total memory size in the system (beyond 96 GB) by going to 2 DPC while maintaining the maximum memory speed at 1600 MHz.

12 x 8GB gives the peak performance for this configuration and is recommended if there is no plan of increasing the total memory in the future.

52 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server

SUPPLEMENTAL MATERIAL

Additional DIMM Populations

The list in Table 28 is not a complete list of all supported DIMM populations, but highlights common

configuration options.

Table 28 Supported DIMM Configurations

CPU 1 DIMMs

1 x 4 GB

2 x 4 GB

1 x 8 GB

3 x 4 GB

4 x 4 GB

2 x 8 GB

1 x 16 GB

5 x 4 GB

6 x 4 GB

3 x 8 GB

4 x 8 GB

2 x 16 GB

3 x 8 GB + 3 x 4 GB 1

5 x 8 GB

6 x 8 GB

3 x 16 GB

3 x 16 GB + 3 x 4 GB 3

4 x 16 GB

3 x 8 GB + 3 x 16 GB 5

5 x 16 GB

6 x 16 GB

6 x 32 GB

5

6

3

6

4

6

5

6

6

1

3

1

2

4

2

1

3

4

5

6

2

6

# CPU 1

DIMMs

CPU 1

Capacity

CPU 2 DIMMs

4 GB

8 GB

1 x 4 GB

2 x 4 GB

8 GB 1 x 8 GB

12 GB 3 x 4 GB

16 GB 4 x 4 GB

16 GB 2 x 8 GB

16 GB 1 x 16 GB

20 GB 5 x 4 GB

24GB 6 x 4 GB

24 GB 3 x 8 GB

32 GB 4 x 8 GB

32 GB 2 x 16 GB

36 GB 3 x 8 GB + 3 x 4 GB 2

40 GB 5 x 8 GB

48 GB 6 x 8 GB

48 GB 3 x 16 GB

60 GB 3 x 16 GB + 3 x 4 GB 4

64 GB 4 x 16 GB

72 GB 3 x 8 GB + 3 x 16 GB 6

80 GB 5 x 16 GB

96 GB 6 x 16 GB

192 GB 6 x 32 GB

5

6

3

6

4

6

5

6

6

20 GB

24GB

24 GB

32 GB

32 GB

36 GB

4 GB

8 GB

8 GB

12 GB

16 GB

16 GB

16 GB

40 GB

48 GB

48 GB

60 GB

64 GB

72 GB

80 GB

96 GB

192 GB

# CPU 2

DIMMs

CPU 2

Capacity

Total

DIMMs for both CPUs

Total

Capacity for 2 CPUs

1

3

1

2

4

2

1

3

4

5

6

2

6

2

4

2

6

8

4

2

10

12

6

8

4

12

10

12

6

12

8

12

10

12

12

8 GB

16 GB

16 GB

24 GB

32 GB

32 GB

32 GB

40 GB

48 GB

48 GB

64 GB

64 GB

72 GB

80 GB

96 GB

96 GB

120 GB

128 GB

144 GB

160 GB

192 GB

384 GB

Notes . . .

1. UCS-MR-1X082RY-A + UCS-MR-1X041RY-A

2. UCS-MR-1X082RY-A + UCS-MR-1X041RY-A

3. UCS-MR-1X162RY-A + UCS-MR-1X041RY-A

4. UCS-MR-1X162RY-A + UCS-MR-1X041RY-A

5. UCS-MR-1X082RY-A + UCS-MR-1X162RY-A

6. UCS-MR-1X082RY-A + UCS-MR-1X162RY-A

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 53

SUPPLEMENTAL MATERIAL

Low-Voltage DIMM Considerations

The C22 M3 server can be ordered with low-voltage (1.35 V) DIMMs only. Note the following considerations:

Low-voltage DIMMs within the server must have the identical manufacturer, type, speed, and size.

Low-voltage DIMMs and standard-voltage DIMMs can be mixed in the same server. Note that this causes the system BIOS to default to standard-voltage operation (Performance Mode).

That is, the server cannot operate in Power Saving Mode unless all DIMMs are low-voltage

DIMMs.

CPUs that have a maximum memory frequency less than 1333 MHz support low-voltage

DIMMs operating in Power Saving Mode only, and do not support Performance Mode.

54 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server

SUPPLEMENTAL MATERIAL

RAID Summary

ROM5 and ROM55 embedded RAID upgrade options each support up to 8 drives.

The LSI MegaRAID SAS 9270CV-8i, 9240-8i, and 9220-8i RAID controller cards each support up to 8 drives

NOTE: If you do not select a PCIe RAID controller or one of the embedded RAID upgrade options (ROM5 or ROM55), you will have an embedded SATA-only RAID controller that supports up to four SATA-only drives (RAID 0, 1, 10).

See Table 29

for a summary of the supported RAID configuration options.

Table 29 Supported RAID Configurations

Server # CPUs

Embedded

RAID

Internal PCIe

RAID #1 1

Internal PCIe

RAID #2

# Drives

Supported

PCIe Slots

1 2

C22 M3 SFF

C22 M3 SFF

1

1

2

Not allowed

Enabled

Not allowed

Installed slot 1 (default) 3

Not allowed

Installed slot 2 (default)

Not allowed

Not allowed

Not allowed

Not allowed

8 internal

8 internal

8 internal

O

A

A

U

2 Enabled Not allowed 8 internal A

Notes . . .

1. If you want to boot from a device other than the 9270CV-8i, 9240-8i, or 9220-8i MegaRAID PCIe cards, you can leave the cards installed. Just disable the OPROM for their slots, and the system will boot even with the cards installed.

2. A = available slot, O = occupied slot, U = unsupported slot (slot 2 is not supported in 1-CPU systems)

3. The OPROM is enabled for the default PCIe RAID controller slots. If you want to enable a different slot, you must go into the BIOS and enable the OPROM for the desired slot and disable the OPROM for the default PCIe slot (see

Figure 8 on page 56

).

A

U

O

2

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 55

SUPPLEMENTAL MATERIAL

RAID Option ROM (OPROM) Settings

The server contains an Option ROM (OPROM) for the PCIe slots. The server has a finite amount of option

ROM with which it can boot up devices. Go into the BIOS and disable the OPROM on the PCIe slots not used for booting so that resources are available for the slots that are used for booting. An example OPROM BIOS screen is shown in

Figure 8

.

Figure 8 Example BIOS Screen for OPROM

56 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server

SUPPLEMENTAL MATERIAL

RACKS

The Cisco R42610 rack (see

Figure 9 ) is certified for Cisco UCS installation at customer sites and is suitable

for the following equipment:

Cisco UCS B-Series servers and fabric interconnects

Cisco UCS C-Series and select Nexus switches

The rack is compatible with hardware designed for EIA-standard 19-inch racks. Rack specifications are

listed in Table 30 .

Table 30 Cisco R42610 Rack Specifications

Parameter

Dimensions (H x W x D)

Dimensions (H x W x D) with packaging

Distance from front mounting rail to rear mounting rail

Weight

Weight with packaging

Side panels included

Equipment mounting capacity

Static load capacity

Standard Rack

78.74 x 24 x 43.38 in.

(2000 x 610 x 1102 mm)

89 x 33 x 47 in.

(2261 x 838 x 1194 mm)

29.2 in (741 mm)

299.83 lb (136 kg)

354 lb

(161 kg)

Yes

42RU

Dynamic load capacity

2100 lb

(954 kg)

Not applicable

Expansion Rack

78.74 x 23.58 x 43.38 in.

(2000 x 599 x 1102 mm)

89 x 33 x 47 in.

(2261 x 838 x 1194 mm)

29.2 in (741 mm)

231. 49 lb (105 kg)

284 lb

(129 kg)

No

42RU

2100 lb

(954 kg)

Not applicable

NOTE: The AC input connector is an IEC 320 C-14 15 A/250 VAC power inlet.

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 57

SUPPLEMENTAL MATERIAL

Figure 9 Cisco R42610 Rack

Front view - door closed Front view - door open Front view - door removed

58 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server

SUPPLEMENTAL MATERIAL

PDUs

Cisco RP Series Power Distribution Units (PDUs) offer power distribution with branch circuit protection.

Cisco RP Series PDU models distribute power to up to 24 outlets. The architecture organizes power distribution, simplifies cable management, and enables you to move, add, and change rack equipment without an electrician.

With a Cisco RP Series PDU in the rack, you can replace up to two dozen input power cords with just one.

The fixed input cord connects to the power source from overhead or under-floor distribution. Your IT equipment is then powered by PDU outlets in the rack using short, easy-to-manage power cords.

The C-series severs accept the zero-rack-unit (0RU) PDU. See Figure 10 ).

Figure 10 Zero Rack Unit PDU (PID = RP208-30-2P-U-2)

1

2

Breakers

Ground connection

3

4

C13 plugs

C19 plugs

Cisco RP Series PDU models provide two 20-ampere (A) circuit breakers for groups of receptacles. The effects of a tripped circuit are limited to a receptacle group. Simply press a button to reset that circuit.

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 59

SUPPLEMENTAL MATERIAL

Motherboard USB Port

The C22 M3 SFF motherboard has one general-purpose USB socket as shown in Figure 11

.

Figure 11 Motherboard USB Port

SYS FAN1

SYS FAN2

SYS FAN3

SYS FAN4

SYS FAN5

CPU 1 PCIe 1

PCIe 2

CPU 2

PSU 1

1 Internal USB 2.0 port

(on motherboard under PCIe riser 1)

-

1

60 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server

SUPPLEMENTAL MATERIAL

LED Indicators

The server contains LED indicators on the front and rear panels. Their functions are described in the following sections.

Front Panel

Figure 12 shows the front panel LEDs.

Figure 12 Front Panel LEDs

1 2 3 4 5 6 7 8 9

HDD01

HDD06

HDD02

HDD07

HDD03

HDD08

3

4

1

2

5

Power button/Power status LED

Identification button/LED

System status LED

Fan status LED

Temperature status LED

See

Table 31 for the functions of the front panel LEDs.

8

9

6

7

Power supply status LED

Network link activity LED

Hard drive fault LED

Hard drive activity LED

Table 31 Front Panel LEDs

LED

Power

(LED is integrated into power button)

LED State

Off

On (amber)

Unit ID

(LED is integrated into unit ID button)

On (green)

Off

On (blue)

Meaning

Server power is off

Server power is soft off (power is supplied only to the

CIMC and some motherboard functions)

Card power is on

Unit ID not active

Unit ID is activated

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 61

SUPPLEMENTAL MATERIAL

Table 31 Front Panel LEDs (continued)

LED

System Status

Fan Status

Temperature Status

Power Supply Status

Network Link Status

LED State

Off

On (green)

On (amber)

Blinking (amber)

Off

On (green)

On (amber)

Blinking (amber)

Off

On (green)

On (amber)

Blinking (amber)

Off

On (green)

On (amber)

Blinking (amber)

Off

On (green)

Meaning

Undefined

Server is in normal operating condition

Server is in a degraded operational state. For example:

■ Power supply redundancy is lost.

■ CPUs are mismatched.

■ At least one CPU is faulty.

■ At least one DIMM is faulty.

■ At least one drive in a RAID configuration failed.

Server is in a critical fault state. For example:

■ Boot failed.

■ Fatal CPU and/or bus error is detected.

■ Server is in over-temperature condition

Undefined

Fans are operating and no error condition has been detected

Fans are in a degraded operational state, indicating that one of the fans has a fault.

Critical fault state, indicating that two or more fans have a fault.

Undefined

System is operating at normal temperature and no error conditions have been detected.

One or more temperature sensors exceeded a warning threshold.

One or more temperature sensors exceeded a critical threshold

Undefined

AC power supplies are operating and no error condition has been detected.

One or more power supplies are in a degraded operational state.

One or more power supplies are in a critical fault state.

Undefined

Link pulses detected on any of the LOM ports, but no activity.

62 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server

SUPPLEMENTAL MATERIAL

Table 31 Front Panel LEDs (continued)

LED

Hard Drive Fault

Hard Drive Activity

LED State

Blinking (green)

Off

On (amber)

Blinking (amber)

Off

On (green)

Blinking (green)

Rear Panel

Figure 13 shows the rear panel LEDs.

Figure 13 Rear Panel LEDs

Meaning

Activity on any of the LOM ports

The hard drive is operating properly

The hard drive has failed

The hard drive is rebuilding

There is no hard drive in the hard drive sled (no access, no fault)

The hard drive is ready

The hard drive is reading or writing data

PCIe 2 PCIe 1

PSU 1

1 2

3

4 6

5 7

1

2

3

4

Power supply fault LED

Power supply AC OK LED

1-Gb Ethernet link speed LED

1-Gb Ethernet link status LED

5

6

7

10/100/1000 Ethernet dedicated management link status LED

10/100/1000 Ethernet dedicated management link speed LED

Rear Identification button/LED

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 63

SUPPLEMENTAL MATERIAL

See

Table 32 for the functions of the rear panel LEDs.

Table 32 Rear Panel LEDs

LED

Power Supply Fault

LED State

Off

Blinking (amber)

Power Supply AC

1GbE Link Speed

1GbE Link Status

On (amber)

Off

Blinking (green)

On (green)

Off

On (amber)

On (green)

Off

On (green)

Meaning

The power supply is operating normally

An event warning threshold has been reached, but the power supply continues to operate

A critical fault threshold has been reached, causing the power supply to shut down (for example, a fan failure or an over-temperature condition).

There is no AC power to the power supply

AC power OK, DC output not enabled

AC power OK, DC outputs OK

Link Speed = 10 Mbps

Link Speed = 100 Mbps

Link Speed = 1 Gbps

No Link

Link is active

10/100/1000 Base-T

Link Status

10/100/1000 Base-T

Link Speed

Unit ID

(LED is integrated into unit ID button)

Blinking (green)

Off

On (green)

Blinking (green)

Off

On (amber)

On (green)

Off

On (blue)

Traffic is present on the active link

No Link

Link is active

Traffic is present on the active link

Link Speed = 10 Mbps

Link Speed = 100 Mbps

Link Speed = 1 Gbps

Unit ID not active

Unit ID is activated

64 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Dimensions and Weight

Table 33 UCS C22 M3 Dimensions and Weight

Parameter

Height

Width

Depth

Front Clearance

Side Clearance

Rear Clearance

Weight

Maximum (8 HDDs, 2 CPUs, 12 DIMMs, 1 power supply)

Bare (0 HDD, 0 CPU, 0 DIMM, no power supply)

Value

1.70 in (43.2 mm)

16.93 in.(430 mm)

26.0 in. (660.4 mm)

3 in. (76 mm)

1 in. (25 mm)

9 in. (233 mm)

27.78 lbs (12.6 kg)

23.48 lbs (10.65 kg)

Power Specifications

The general power specifications for the C22 M3 SFF server 450 W power supply are listed in Table 34 .

Table 34 UCS C22 M3 SFF 450 W Power Supply Specifications

Description

AC input voltage

AC input frequency

Maximum AC input current

Maximum AC inrush current

Maximum output power for the power supply

Power supply output voltage

Specification

90 to 264 VAC self-ranging

100 to 120 VAC nominal

200 to 240 VAC nominal

Range: 47 to 63 Hz (single phase, 50 to 60 Hz nominal)

6 A maximum at 100 VAC

3 A maximum at 208 VAC

9 A peak @ 35° C, 208 VAC

450 W

Power supply efficiency

Main power: 12 VDC

Standby power: 12 VDC

CSCI Platinum

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 65

TECHNICAL SPECIFICATIONS

NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet.

The general power specifications for the C22 M3 SFF server 650 W power supply are listed in Table 34 .

Table 35 UCS C22 M3 SFF 650 W Power Supply Specifications

Description

AC input voltage

AC input frequency

Maximum AC input current

Maximum AC inrush current

Maximum output power for the power supply

Power supply output voltage

Specification

90 to 264 VAC self-ranging,

100 to 120 VAC nominal

200 to 240 VAC nominal

Range: 47 to 63 Hz (single phase, 50 to 60 Hz nominal)

7.6 A maximum at 100 VAC

3.65 A maximum at 208 VAC

11 A peak @ 35° C, 208 VAC

650 W

Power supply efficiency

Main power: 12 VDC

Standby power: 12 VDC

CSCI Platinum

NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet.

For configuration-specific power specifications, use the Cisco UCS Power Calculator at this URL: https://mainstayadvisor.com/Go/Cisco/Cisco-UCS-Power-Calculator.aspx

66 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server

TECHNICAL SPECIFICATIONS

Environmental Specifications

The power specifications for the C22 M3 server are listed in

Table 36 .

Table 36 UCS C22 M3 Environmental Specifications

Parameter

Temperature operating

Minimum

41 to 95° F (5 to 35° C) Maximum temperature is to be derated by 1 degree C for every 305 m (1000 ft.) of altitude above sea level

–40 to 149°F (–40 to 65°C)

10 to 90%

Temperature nonoperating

Humidity (RH) nonoperating, non-condensing

Altitude operating

Altitude nonoperating

Sound Power level, Measure

A-weighted per ISO7779 LWAd (Bels)

Operation at 73°F (23°C)

Sound Pressure level, Measure

A-weighted per ISO7779 LpAm (dBA)

Operation at 73°F (23°C)

0 to 3,000 m (0 to 10,000 ft.)

0 to 12,192 m (0 to 40,000 ft.)

5.9

46

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 67

TECHNICAL SPECIFICATIONS

Compliance Requirements

The regulatory compliance requirements for C-Series servers are listed in

Table 37

.

Table 37 UCS C-Series Regulatory Compliance Requirements

Parameter

Regulatory Compliance

Safety

EMC - Emissions

EMC - Immunity

Description

Products should comply with CE Markings per directives

2004/108/EC and 2006/95/EC

UL 60950-1 Second Edition

CAN/CSA-C22.2 No. 60950-1 Second Edition

EN 60950-1 Second Edition

IEC 60950-1 Second Edition

AS/NZS 60950-1

GB4943 2001

47CFR Part 15 (CFR 47) Class A

AS/NZS CISPR22 Class A

CISPR22 Class A

EN55022 Class A

ICES003 Class A

VCCI Class A

EN61000-3-2

EN61000-3-3

KN22 Class A

CNS13438 Class A

EN55024

CISPR24

EN300386

KN24

68 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project