advertisement
Spec Sheet
Cisco UCS C22 M3
High-Density Rack-Mount
Server
(Small Form Factor Hard
Disk Drive Model)
C ISCO S YSTEMS
170 W EST T ASMAN D R .
S AN J OSE , CA, 95134
WWW .
CISCO .
COM
P UBLICATION H ISTORY
R EV B.14
J ANUARY 5, 2015
CONTENTS
BASE SERVER STANDARD CAPABILITIES and FEATURES . . . . . . . . . . . . . . . . . 6
CONFIGURING the SERVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . 26
STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM . . . . . . . . . . . . . . . . . 34
STEP 11 ORDER A TRUSTED PLATFORM MODULE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
STEP 13 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE . . . . . . . . . . . . . . . . 37
OPTIONAL STEP - ORDER RACK(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
OPTIONAL STEP - ORDER PDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
SUPPLEMENTAL MATERIAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 2
OVERVIEW
OVERVIEW
The Cisco® UCS C22 M3 small form factor (SFF) drive Rack Server combines economics and a density-optimized feature set from entry level enterprise to SMB with applications such as scale out, virtualization, IT and web infrastructure, VPN servers, file/print servers, and appliances.
Building on the success of the Cisco UCS C-Series Servers, the Cisco UCS C22 M3 server and the Cisco 1225
VIC further extend the capabilities of the Cisco UCS portfolio in a 1RU form factor with the addition of the
Intel® Xeon® E5-2400 v2 and E5-2400 series processor family CPUs, which delivers the best combination of performance and efficiency gains. In addition, the Cisco UCS C22 M3 server offers 12 DIMM slots, up to eight disk drives, two PCIe slots and two 1 Gigabit Ethernet LAN-on-motherboard (LOM) ports that provide both price/performance in a compact 1U form factor.
Figure 1 Cisco UCS C22 M3 High-Density SFF Rack Server
Front View
Rear View
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 3
DETAILED VIEWS
DETAILED VIEWS
Chassis Front View
Figure 2 shows the Cisco UCS C22 M3 High-Density SFF Rack Server.
Figure 2 Chassis Front View
1 2 3 4 5 6 7 8
9
3
4
1
2
5
Power button/power status LED
Identification button/LED
System status LED
Fan status LED
Temperature status LED
HDD01
HDD06
10
HDD02
HDD07
HDD03
HDD08
8
9
6
7
10
Power supply status LED
Network link activity LED
USB 2.0 ports (two)
Pull-out asset tag
Drives
(up to eight hot-swappable 2-5-inch drives)
4 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
DETAILED VIEWS
Chassis Rear View
Figure 3 shows the external features of the rear panel.
Figure 3 Chassis Rear View
1 2 3
1
2
3
4
5
4
Power supply
Slot 2: Low-profile PCIe slot on riser 2
PCIe Gen 3 slot, x8, half-height, half-length
Slot 1: Standard-profile PCIe slot on riser 1
PCIe Gen 3 slot, x16, full-height, half-length
Dual 1-Gb Base-T Ethernet ports (two)
USB 2.0 ports (four)
6
7
8
9
—
5 6 7 8 9
Serial port (DB-9 connector)
VGA video port (DB-15 connector)
10/100/1000 Base-T Ethernet dedicated management port
Rear Identification button/LED
—
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 5
BASE SERVER STANDARD CAPABILITIES and FEATURES
BASE SERVER STANDARD CAPABILITIES and FEATURES
lists the capabilities and features of the base server. Details about how to configure the server for a particular feature or capability (for example, number of processors, disk drives, or amount of memory)
are provided in CONFIGURING the SERVER, page 9
.
Table 1 Capabilities and Features
Capability/Feature
Chassis
CPU
Chipset
Memory
NIC
Expansion slots
Internal storage devices
Video
Description
Single rack unit (1RU) chassis
One or two Intel® Xeon E5-2400 v2 or E5-2400 series processor family CPUs
Intel C600 chipset
12 DIMM slots
Embedded dual-port Intel I350 PCIe-based Gigabit Ethernet controller
Two riser cards with one PCIe card slot in each riser
■ Riser 1 (controlled by CPU 1)
• Slot 1: PCIe Gen 3 slot, x16 extended connector (Cisco CNIC), half-length, full-height, with NCSI 1 and Cisco CNIC 2 support. The
Cisco 1225 virtual interface card requires an NCSI slot.
■ Riser 2 (controlled by CPU 2)
• Slot 2: PCIe Gen 3 slot, x8 connector, half-length, half-height, no
NCSI support
■ Up to eight 2.5-inch SAS+SATA hot-swappable hard disk drives (HDDs) or solid state drives (SSDs)
■ One connector on the motherboard that can accommodate a USB 2.0 drive. You can order an 8 or 16 GB drive for this connector and use it as a hypervisor or license dongle. The 8 or 16 GB USB drive comes blank.
The Emulex Pilot 3 Integrated Baseboard Management Controller provides video:
■ Matrox G200e video controller
■ Integrated 2D graphics core with hardware acceleration
■ Supports all display resolutions up to 1920 x 1200 x 16 bpp resolution at
60 Hz
■
■
24-bit color depth for all resolutions less than 1600x1200
8 MB video memory
6 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
Capability/Feature
Storage controller
Interfaces
Front Panel
Power subsystem
Fans
BASE SERVER STANDARD CAPABILITIES and FEATURES
Description
The following RAID options are available:
■ Embedded RAID (3 Gbps) (these implementations of RAID do not consume a PCIe slot).
• Embedded SATA-only RAID controller, supporting up to four SATA-only drives (RAID 0, 1, 10), or
• ROM5 RAID upgrade, supporting up to eight SAS+SATA drives (RAID 0,
1, 10), or
■
• ROM55 RAID upgrade, supporting up to eight SAS+SATA drives (RAID 0,
1, 5, 10).
PCIe RAID controllers (these consume PCIe slots)
• LSI MegaRAID 9270CV-8i with 1 GB Transportable Memory Module
(TMM) data cache and chassis-mounted (remote) supercap for data cache power backup, supporting RAID 0, 1, 5, 6, 10, 50, and 60 and up to eight internal SAS+SATA drives.
• LSI MegaRAID 9240-8i RAID 8-port PCIe RAID controller, supporting
RAID 0, 1, 5, 10, and 50 and up to eight internal SAS+SATA drives.
• LSI MegaRAID 9220-8i RAID 8-port PCIe RAID controller supporting
RAID 0, 1, and 10 and up to eight internal SAS+SATA drives.
■
■
Rear panel
• One DB9 serial port connector
• Four USB 2.0 port connectors
• One DB15 VGA connector
• One 10/100/1000 Ethernet management port
• Two 1 GbE (10/100/1000 Mbps capable) Ethernet LOM ports
Front panel
• Two USB 2.0 ports
■ A front panel controller provides status indications and control buttons
One 450 W power supply or one 650 W power supply, depending on server configuration and loading. Prior to making a power supply selection, the UCS
Power Calculator should be run to determine the right size power supply for your server configuration. A fully configured C22 M3 server may require the
650 W power supply. The UCS Power Calculator can be found at the following link: https://mainstayadvisor.com/Go/Cisco/Cisco-UCS-Power-Calculator.aspx
Chassis:
■ Five fans for front-to-rear cooling. N + 1 redundant.
Power supply:
■ The power supply is equipped with a fan.
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 7
BASE SERVER STANDARD CAPABILITIES and FEATURES
Capability/Feature
Integrated management processor
Description
Cisco Integrated Management Controller (CIMC).
Depending on your CIMC settings, the CIMC can be accessed through the 1-Gb
Ethernet dedicated management port, the 1-Gb Ethernet LOM ports, or a
Cisco 1225 virtual interface card.
Notes . . .
1. NCSI = network communications services interface protocol. The slot stays active when the server is in standby power state.
2. CNIC = Cisco network interface card.
8 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
CONFIGURING the SERVER
CONFIGURING the SERVER
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
Follow these steps to configure the Cisco UCS C22 M3 High-Density SFF Rack Server:
STEP 1 VERIFY SERVER SKU, page 10
STEP 4 SELECT RAID CONFIGURATION, page 17
STEP 6 SELECT PCIe OPTION CARD(s), page 24
STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES, page 26
STEP 8 SELECT AC POWER CORD(s), page 30
STEP 9 ORDER POWER SUPPLY, page 33
STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM, page 34
STEP 11 ORDER A TRUSTED PLATFORM MODULE, page 35
STEP 12 ORDER OPTIONAL USB 2.0 DRIVE, page 36
STEP 13 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE, page 37
STEP 14 SELECT OPERATING SYSTEM MEDIA KIT, page 40
STEP 15 SELECT SERVICE and SUPPORT LEVEL, page 41
OPTIONAL STEP - ORDER RACK(s), page 46
OPTIONAL STEP - ORDER PDU, page 47
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 9
CONFIGURING the SERVER
STEP 1 VERIFY SERVER SKU
Verify the product ID (PID) of the server as shown in
.
Table 2 PID of the C22 M3 High-Density SFF Rack Base Server
Product ID (PID)
UCSC-C22-M3S UCS C22 M3 SFF with rail kit, without PSU, CPU, memory, HDD, SSD, or PCIe cards
Description
■
■
The Cisco C22 M3 server:
Includes a rail kit (UCSC-RAIL1)
Does not include power supply, CPU, memory, hard disk drives (HDDs), solid state drives
(SSDs), or plug-in PCIe cards.
NOTE: Use the steps on the following pages to configure the server with the components that you want to include.
10 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
CONFIGURING the SERVER
STEP 2 SELECT CPU(s)
■
■
■
The standard CPU features are:
Intel Xeon E5-2400 v2 or E5-2400 series processor family CPUs
Intel C600 chipset
Cache size of up to 25 MB
Select CPUs
The available CPUs are listed in Table 3
.
Table 3 Available Intel CPUs: Xeon E5-24xx Family
Product ID (PID)
Intel
Number
Clock
Freq
(GHz)
Power
(W)
Cache
Size
(MB)
Cores
QPI
(GT/s)
Highest DDR3
DIMM Clock
Support
(MHz) 1
Intel Xeon E5-2400 v2
UCS-CPU-E52470B E52470 v2
UCS-CPU-E52450B
UCS-CPU-E52440B
E52450 v2
E52440 v2
UCS-CPU-E52430B
UCS-CPU-E52430LB
UCS-CPU-E52420B
UCS-CPU-E52407B
E52430 v2
E52430L v2
E52420 v2
E52407 v2
E52403 v2 UCS-CPU-E52403B
Intel Xeon E5-2400
UCS-CPU-E5-2470
UCS-CPU-E5-2450
UCS-CPU-E5-2440
UCS-CPU-E5-2430
UCS-CPU-E5-2430L
E5-2470
E5-2450
E5-2440
E5-2430
E5-2430L
UCS-CPU-E5-2420
UCS-CPU-E5-2407
UCS-CPU-E5-2403
E5-2420
E5-2407
E5-2403
2.4
2.5
1.9
2.5
2.4
2.2
2.4
1.8
2.30
2.10
2.40
2.20
2.00
1.90
2.20
1.80
95
95
95
80
60
80
80
80
95
95
95
95
60
95
80
80
25
20
20
15
15
15
10
10
20
20
15
15
15
15
10
10
10
8
8
6
6
6
4
4
8
8
6
6
6
6
4
4
8.0
8.0
7.2
7.2
7.2
7.2
6.4
6.4
8.0
8.0
7.2
7.2
6.4
7.2
6.4
6.4
1600
1600
1600
1600
1600
1600
1333
1333
Notes . . .
1. If higher or lower speed DIMMs are selected than what is shown in the table for a given CPU, the DIMMs will be clocked at the lowest common denominator of CPU clock and DIMM clock.
1600
1600
1333
1333
1333
1333
1066
1066
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 11
CONFIGURING the SERVER
Approved Configurations
(1) 1-CPU configurations:
■ Select any one CPU listed in
(2) 2-CPU Configurations:
■
Select two identical CPUs from any one of the rows of Table 3 on page 11
.
Caveats
■
■
■
You can select either one CPU or two identical CPUs.
If you select one CPU, only one PCIe slot (the full-height slot on riser 1) is available for use.
For optimal performance, select DIMMs with the highest clock speed for a given processor
). If you select DIMMs whose speeds are lower or higher than that shown in the tables, suboptimal performance will result.
12 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
CONFIGURING the SERVER
STEP 3 SELECT MEMORY
Figure 4
The standard memory features are:
■
■
DIMMs
— Clock speed: 1600 or 1333 MHz
— Ranks per DIMM: 1, 2, or 4
— Operational voltage: 1.35 V or 1.5 V
— Registered ECC DDR3 DIMMS (RDIMMS), unregistered DIMMs (UDIMMs), or load-reduced DIMMs (LRDIMMs)
Memory is organized with three memory channels per CPU, with up to two DIMMs per channel, as shown in
.
C22 M3 SFF Memory Organization
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 13
CONFIGURING the SERVER
Select DIMMs
Select the memory configuration. The available memory DIMMs are listed in
.
NOTE: When memory mirroring is enabled, the memory subsystem simultaneously writes identical data to two channels. If a memory read from one of the channels returns incorrect data due to an uncorrectable memory error, the system automatically retrieves the data from the other channel. A transient or soft error in one channel does not affect the mirrored data, and operation continues unless there is a simultaneous error in exactly the same location on a DIMM and its mirrored
DIMM. Memory mirroring reduces the amount of memory available to the operating system by 50% because only one of the two populated channels provides data.
Table 4 Available DDR3 DIMMs
Product ID (PID) PID Description
DIMM Options
UCS-MR-1X041RY-A
UCS-MR-1X082RY-A
UCS-MR-1X162RY-A
UCS-ML-1X324RY-A
4GB DDR3-1600-MHz RDIMM/PC3-12800/1R/x4/1.35v
8GB DDR3-1600-MHz RDIMM/PC3-12800/2R/x4/1.35v
16GB DDR3-1600-MHz RDIMM/PC3-12800/2R/x4/1.35v
32GB DDR3-1600-MHz LR DIMM/PC3-12800/4R/x4/1.35v
Memory Mirroring Option
N01-MMIRROR Memory mirroring option
Voltage
1.35 V
1.35 V
1.35 V
1.35 V
Ranks
/DIMM
1
2
2
4
14 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
CONFIGURING the SERVER
Approved Configurations
(1) 1-CPU configuration without memory mirroring:
■ Select from 1 to 6 DIMMs. Refer to
Memory Population Rules, page 51 , for more detailed
information.
(2) 1-CPU configuration with memory mirroring:
■ Select either 2 or 4 DIMMs. The DIMMs will be placed by the factory as shown in the following table:
Number of
DIMMs
2
4
DIMM Placement in Channels
(Channel A is not used with memory mirroring)
CPU 1: 1 DIMM in Channel B, 1 DIMM in Channel C
CPU 1: 2 DIMMs in Channel B, 2 DIMMs in Channel C
■
Select the memory mirroring option (N01-MMIRROR) as shown in
(1) 2-CPU configuration without memory mirroring:
■
Select from 1 to 6 DIMMs per CPU (2 to 12 DIMMs total). Refer to Memory Population Rules, page 51
, for more detailed information.
(2) 2-CPU configuration with memory mirroring:
■ Select 2 or 4 DIMMs per CPU (4 or 8 DIMMs total). The DIMMs will be placed by the factory as shown in the following table:
Number of
DIMMs per
CPU
2
4
CPU 1:
1 DIMM in Channel B
1 DIMM in Channel C
CPU 1:
2 DIMMs in Channel B
2 DIMMs in Channel C
DIMM Placement
(Channels A and D are not used with memory mirroring)
CPU 2:
1 DIMM in Channel E
1 DIMM in channel F
CPU 2:
2 DIMMs in Channel E
2 DIMMs in Channel F
■
Select the memory mirroring option (N01-MMIRROR) as shown in Table 4 on page 14 .
NOTE: System performance is optimized when the DIMM type and quantity are equal for both CPUs.
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 15
CONFIGURING the SERVER
Caveats
■
■
■
■
■
■
Do not mix 1333 MHz and 1600 MHz DIMMs
Do not mix DIMM types (RDIMM, LRDIMM, or UDIMM)
Do not select more than two different types of DIMMs (only two PID types allowed)
For 2-CPU configurations, install a minimum of 2 DIMMs (one per CPU).
If you use different sizes of DIMMs, the quantity of each size of DIMM must be even (2, 4, or
6). For example, 4 UCS-MR-1X082RY-A DIMMs and 6 UCS-MR-1X162RY-A DIMMs. Also, the sum of all PIDs must adhere to the maximum quantity rule of 12 DIMMs for 2-CPU systems.
By default, all DIMMs run at 1.35 V, which yields 1333-MHz memory speeds. To run the memory DIMMS at 1600 MHz, you need to go into the BIOS or set the policy with UCSM
(service profile) to run in Performance Mode. This forces the DIMMs to operate at 1.5 V and yields 1600-MHz speeds, provided:
— The DIMMs are 1600-MHz devices
— The CPUs chosen support 1600-MHz operation.
NOTE: 32 GB LRDIMMs run at a maximum speed of 1333 MHz for 1 DPC and 2 DPC even though their specified maximum speed is 1600 MHz.
NOTE: In this server, 4 GB UDIMMs run slower than their specified maximum speed of
1600 MHz. In addition, the following rules apply to UDIMMs:
■
■
1 DPC: 1333 MHz is supported at 1.35 V and 1.5 V
2 DPC: 1066 MHz is supported at 1.35 V and 1.5 V
For more information regarding memory, see CPUs and DIMMs, page 49
.
16 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
CONFIGURING the SERVER
STEP 4 SELECT RAID CONFIGURATION
NOTE: If you do not select a PCIe RAID controller or one of the embedded RAID upgrade options, you will have an embedded SATA-only RAID controller that supports up to four SATA-only drives (RAID 0, 1, 10)
NOTE: When creating a RAID volume, follow these guidelines:
■
■
■
Use the same capacity for each drive in the volume
Use either all SAS drives or all SATA drives
Use either all HDDs or all SSDs
NOTE: The number of RAID groups (virtual drives) supported per controller is as follows (note however, that this server can have a maximum of only eight internal physical drives):
■
■
■
LSI MegaRAID SAS 9270CV-8i RAID controller card = 64
LSI MegaRAID 9240-8i RAID controller card = 16
LSI MegaRAID 9220-8i RAID controller card = 16
The RAID controller choices are:
(1) Embedded RAID (on motherboard)\
NOTE: Embedded RAID is not available with VMWare.
NOTE: The RAID configuration options listed in
are not available if you choose embedded RAID (in this case, you must configure RAID yourself using separate software).
(2) PCIe RAID controllers
Cisco can provide factory-configured RAID systems depending on the RAID controller chosen and the number of drives ordered. Factory-configured RAID options are listed with each RAID card description.
RAID levels 50 and 60 are supported, although they are not available as factory-configured RAID options.
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 17
CONFIGURING the SERVER
Select RAID Options
Select one RAID controller (either embedded RAID in
or hardware RAID using a PCIe RAID controller and an appropriate RAID configuration option listed in
Table 5 Available Embedded RAID (LSI MegaSR) Options
Product ID (PID)
Embedded RAID
UCSC-RAID-ROM5
PID Description
UCSC-RAID-ROM55
Onboard RAID, consisting of a plug-in storage controller unit (SCU), supporting up to 8 internal SAS +SATA drives. SAS and SATA drives can be mixed. This option supports RAID 0, 1, and 10, and operates at 3 Gb/s. Operating systems supported are Windows and Linux only (no VMware support).
Onboard RAID, consisting of two plug-in modules (an SCU plus a software key module) supporting up to 8 internal SAS+SATA drives. SAS and SATA drives can be mixed. This option supports RAID 0, 1, 5, and 10 and operates at 3 Gb/s.
Operating systems supported are Windows and Linux only (no VMware support).
NOTE: VMware ESX/ESXi or any other virtualized environments are not supported for use with the embedded MegaRAID controller. Hypervisors such as Hyper-V, Xen, or
KVM are also not supported for use with the embedded MegaRAID controller
Table 6 Available Hardware RAID Options
Product ID (PID) PID Description
RAID Controllers
Note that PCIe RAID controllers are installed by default in slot 1 for 1-CPU systems and slot 2 for
2-CPU systems
UCSC-RAID-9240-8I LSI MegaRAID 9240-8i
■ Supports up to 8 internal SAS+SATA drives. SAS and SATA drives can be mixed.
■ RAID levels supported: RAID 0, 1, 5, 10, 50 (see the RAID Configuration
Options section later in this table)
UCSC-RAID-9220-8I LSI MegaRAID 9220-8i
■ Supports up to 8 internal SAS+SATA drives. SAS and SATA drives can be mixed.
■ RAID levels supported: RAID 0, 1, 10 (see the RAID Configuration Options section later in this table)
18 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
CONFIGURING the SERVER
Table 6 Available Hardware RAID Options (continued)
Product ID (PID) PID Description
UCS-RAID9270CV-8i LSI MegaRAID 9270CV-8i (with supercap power backup)
■ Supports up to 8 internal SAS+SATA drives. SAS and SATA drives can be mixed.
■ Includes a 1 GB Transportable Memory Module (TMM) cache and chassis-mount (remote) supercap power module for data cache backup
■ RAID levels supported: RAID 0, 1, 5, 6, 10, 50, 60 (see the RAID
Configuration Options section later in this table)
RAID Configuration Options (not available for embedded RAID)
R2XX-RAID0 Factory preconfigured RAID striping option
Enable RAID 0 Setting. Requires a minimum of one hard drive.
R2XX-RAID1
R2XX-RAID5
R2XX-RAID6
R2XX-RAID10
Factory preconfigured RAID mirroring option
Enable RAID 1 Setting. Requires exactly two drives with the same size, speed, capacity.
Factory preconfigured RAID option
Enable RAID 5 Setting. Requires a minimum of three drives of the same size, speed, capacity.
Factory preconfigured RAID option
Enable RAID 6 Setting. Requires a minimum of four drives of the same size, speed, capacity.
Factory preconfigured RAID option
Enable RAID 10 Setting. Requires an even number of drives (minimum of four drives) of the same size, speed, capacity.
NOTE: Although RAID levels 50 and 60 are not orderable from the factory, they are supported for selected controllers as shown in
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 19
CONFIGURING the SERVER
Approved Configurations
(1) 1-CPU Configurations
Select an embedded RAID option from Table 5 on page 18
or one PCIe RAID controller from
Table 6 on page 18 . You may also select an appropriate optional RAID configuration listed in
NOTE: In 1-CPU configurations, PCIe slot 1 is the default slot supported for an internal drive RAID controller. PCIe slot 2 is not supported for 1-CPU systems.
NOTE: If you do not select a PCIe RAID controller or one of the embedded RAID
upgrade options from Table 5 on page 18 , you will have an embedded SATA-only
RAID controller that supports up to four SATA-only drives (RAID 0, 1, 10) and slot 1 can be used for a PCIe RAID controller (see
(2) 2-CPU Configurations
Select an embedded RAID option from Table 5 on page 18
, or one PCIe RAID controller from
Table 6 on page 18 . You may also select an appropriate optional RAID configuration listed in
NOTE: In 2-CPU configurations, PCIe slot 2 is the default slot supported for an internal drive RAID controller. PCIe slot 1 can be used for a PCIe expansion card
(including the VIC card). You can change the default card slot for a RAID controller to slot 1 by going into the BIOS and reconfiguring the option ROM (OPROM) settings.
Keep in mind, however, that if you use slot 1 for a RAID controller, you will not be able to install a VIC card, which can be installed only in slot 1.
NOTE: If you do not select a PCIe RAID controller, or one of the embedded RAID
upgrade options from Table 5 on page 18 , you will have an embedded SATA-only
RAID controller that supports up to four SATA-only drives (RAID 0, 1, 10) and slots 1 and 2 can be used for PCIe cards (see
Caveats
■ In 1-CPU configurations, there is only one full-height PCIe slot available (located on riser 1).
Slot 2 is not supported in 1-CPU systems.
— If you choose embedded RAID, you can select one optional PCIe card from
Table 8 on page 24 to be installed in slot 1.
— If you choose a PCIe RAID controller from Table 5 on page 18 , it will be installed in
slot 1 by default and you will not be able to select any optional PCIe card from
20 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
CONFIGURING the SERVER
■
■
■
■
■
— Note that only a single Cisco 1225 Virtual Interface Card (VIC) card is supported and it must be installed in the full-length, full-height PCIe slot (slot 1) on riser 1, which is the only slot that supports NCSI. So take this into account when populating RAID controller cards. You can have either a PCIe RAID controller or a VIC card in slot 1.
— Slot 2 is not supported in 1-CPU systems.
In 2-CPU configurations, there are two PCIe slots available (one full-height slot, slot 1, and one half-height slot, slot 2).
— If you choose embedded RAID, you can select up to two optional PCIe cards from
Table 8 on page 24 to be installed in slots 1 and 2.
— If you choose a PCIe RAID controller from Table 5 on page 18 , it will be installed in
slot 2 by default and you will be able to select one additional optional PCIe card
to be installed in slot 1.
The optional PCIe RAID controllers are all half-height. If you choose one of these cards in a
2-CPU configuration, only the full-height PCIe card slot will be available for an additional optional PCIe card.
Note that only a single Cisco UCS 1225 Virtual Interface Card (VIC) card is supported and it must be installed in the full-length, full-height PCIe slot (slot 1) on riser 1, which is the only slot that supports NCSI. So take this into account when populating RAID controller cards.
You can choose only one type of RAID controller, either embedded RAID or a PCIe RAID controller. If you choose embedded RAID, slot 1 in a 1-CPU system and slots 1 and 2 in a
2-CPU system are available for adding optional PCIe cards.
For PCIe RAID controllers, you can choose an optional RAID configuration (RAID 0, 1, 5, 6, or
10), which is preconfigured at the factory. The RAID level you choose must be an available
RAID choice for the controller selected. RAID levels 50 and 60 are supported, depending on the RAID controller selected, although they are not available as configuration options.
NOTE: For more important information regarding RAID support, see
RAID Option ROM (OPROM) Settings, page 56
.
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 21
CONFIGURING the SERVER
STEP 5 SELECT DRIVES
■
■
■
The standard disk drive features are:
2.5-inch small form factor
Hot-pluggable
Sled-mounted
Select Drives
The available drives are listed in Table 7 .
Table 7 Available Hot-Pluggable Sled-Mounted HDDs or SSDs
Product ID (PID) PID Description
HDDs
UCS-HDD250G1F111
UCS-HDD300GI2F105
A03-D300GA2
A03-D500GC3
A03-D600GA2
UCS-HDD900GI2F106
A03-D1TBSATA
250 GB 6Gb SATA 7.2K RPM
300 GB 6Gb SAS 15K RPM SFF
300 GB 6Gb SAS 10K RPM SFF
500 GB SATA 7.2K RPM SFF
600 GB 6Gb SAS 10K RPM SFF
900 GB 6Gb SAS 10K RPM SFF
1 TB SATA 7.2K RPM SFF
SSDs
UCS-SD200G0KS2-EP
UCS-SD400G0KS2-EP
UCS-SD800G0KS2-EP
200 GB 2.5 inch Enterprise Performance SAS
400 GB 2.5 inch Enterprise Performance SAS
800 GB 2.5 inch Enterprise Performance SAS
UCS-SD480G0KS2-EV 480 GB 2.5 inch Enterprise Value 6 G SATA SSD
UCS-SD240G0KS2-EV
UCS-SD120G0KS2-EV
240 GB 2.5 inch Enterprise Value 6 G SATA SSD
120 GB 2.5 inch Enterprise Value 6 G SATA SSD
UCS-SD100G0KA2-G
UCS-SD400G0KA2-G
100 GB Read SSD
400 GB Read SSD
Drive
Type
Capacity
SATA
SATA
SATA
SATA
SAS
SAS
SAS
SATA
SATA
SAS
SAS
SATA
SAS
SAS
SATA
200 GB
400 GB
800 GB
480 GB
240 GB
120 GB
100 GB
400 GB
250 GB
300 GB
300 GB
500 GB
600 GB
600 GB
1 TB
22 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
CONFIGURING the SERVER
NOTE: When creating a RAID volume, follow these guidelines:
■
■
■
Use the same capacity for each drive in the volume
Use either all SAS drives or all SATA drives
Use either all HDDs or all SSDs
NOTE: The number of RAID groups (virtual drives) supported per controller is as follows:
■
■
■
LSI MegaRAID SAS 9270CV-8i RAID controller card = 64
LSI MegaRAID 9240-8i RAID controller card = 16
LSI MegaRAID 9220-8i RAID controller card = 16
Approved Configurations
(1) Embedded RAID (LSI MegaSR)
■ Select up to eight SAS/SATA drives (note that none of the RAID configuration options listed in
Table 6 on page 18 can be chosen for embedded RAID). You can mix SAS and SATA drives.
(2) LSI MegaRAID 9270CV-8i (with data cache and supercap), LSI MegaRAID 9240-8i, and LSI
MegaRAID 9220-8i
■ Select up to eight SAS/SATA drives listed in
. You can mix SAS and SATA drives.
(3) None of the Above
■ If you did not select embedded RAID or a PCIe RAID controller, you can only select up to four
SATA drives, which will be controlled by the embedded SATA-only RAID controller.
Caveats
■
■
■
You can mix SATA and SAS drives
If you select one or more SAS drives, you must select either a PCIe RAID controller from
Table 6 on page 18 or an embedded RAID option from Table 5 on page 18
.
If you select four or less SATA-only drives, you can select a PCIe RAID controller from
Table 6 on page 18 or an embedded RAID option from Table 5 on page 18
, or neither. If you select neither, the drives will be controlled by the embedded SATA-only RAID controller.
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 23
CONFIGURING the SERVER
STEP 6 SELECT PCIe OPTION CARD(s)
■
■
■
The standard PCIe card offerings are:
Converged Network Adapters (CNAs)
Network Interface Cards (NICs)
Host Bus Adapters (HBAs)
Select PCIe Option Cards
The available PCIe option cards are listed in Table 8 .
Table 8 Available PCIe Option Cards
Product ID (PID) PID Description
Converged Network Adapters (CNAs)
UCSC-PCIE-CSC-02 Cisco VIC 1225 Dual Port 10Gb SFP+ CNA
UCSC-PCIE-C10T-02 Cisco VIC 1225T Dual Port 10GBaseT CNA
UCSC-PCIE-C40Q-02 Cisco VIC 1285 Dual Port 40Gb QSFP CNA
UCSC-PCIE-ESFP
UCSC-PCIE-Q8362
Emulex OCe11102-FX dual-port 10 GbE FCoE CNA
Qlogic QLE8362 dual-port 10 GbE FCoE CNA
Network Interface Cards (NICs)
N2XX-ABPCI01-M3 Broadcom 5709 Dual-Port Ethernet PCIe Adapter w/TOE for M3 Servers
N2XX-ABPCI03-M3
UCSC-PCIE-BTG
N2XX-AIPCI01
UCSC-PCIE-IRJ45
Broadcom 5709 Quad Port 10/100/1Gb NIC w/TOE iSCSI for M3 Servers
Broadcom 57712 Dual Port 10GbE 10G-BaseT w/TOE
Intel 10GbE 2-Port Niantec Controller with Copper SFP+ Cable
Intel Quad Port GbE controller (this is a quad-port i350 controller)
UCSC-PCIE-ITG
UCSC-PCIE-B3SFP
Intel X540 Dual Port 10GBase-T Adapter
BROADCOM 57810 10Gb AFEX SFP+
Host Bus Adapters (HBAs)
N2XX-AEPCI03 Emulex LPe 11002, 4Gb Fibre Channel PCIe Dual Channel HBA
N2XX-AEPCI05
N2XX-AQPCI03
N2XX-AQPCI05
UCSC-PCIE-Q2672
UCSC-PCIE-E16002
Emulex LPe 12002, 8Gb dual port Fibre Channel HBA
Qlogic QLE2462, 4Gb dual port Fibre Channel HBA
Qlogic QLE2562, 8Gb dual port Fibre Channel HBA
Qlogic QLE2672-CSC, 16Gb Fibre Channel HBA with SR Optics
Emulex LPe16002-M6, 16Gb Fibre Channel HBA with SR Optics
Card
Height
Half
Half
Half
Half
Half
Half
Half
Half
Half
Half
Half
Half
Half
Half
Half
Half
Half
Half
24 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
CONFIGURING the SERVER
Approved Configurations
(1) No PCIe RAID controller
■ If you did not choose a PCIe RAID controller (for example, you selected embedded RAID (LSI
MegaSR) or no RAID controller at all), you can select up to one PCIe option card listed in
Table 8 on page 24 for 1-CPU configurations or up to two cards for 2-CPU configurations.
(2) One PCIe RAID controller
■ If you selected a PCIe RAID controller, you cannot select any additional PCIe cards for 1-CPU configurations; however, you can select one additional optional PCIe card for 2-CPU configurations.
NOTE: If a PCIe RAID controller is installed, any optional PCIe card you select will be installed in the full-height slot. RAID controllers are always installed in the half-height slot (unless you change the OPROM setting to enable the full-height slot, slot 1) for RAID.
Caveats
■
■
■
■
Only a single Cisco UCS 1225 Virtual Interface Card (VIC) card is supported and it must be installed in the full-height slot of riser 1, which is the only slot that supports NCSI.
All PCIe cards will fit in either riser 1 or riser 2, except the VIC card, which must be installed in the full-height slot of riser 1. The Cisco 1225 VIC card must be plugged into slot 1, which supports NCSI.
Additional considerations for the Cisco 1225 VIC card:
— Supports 10G SFP+ optical and copper twinax connections
— The server supports installation of only one Cisco VIC 1225 card and it is supported only in PCIe slot 1. Slot 1 can operate while the server is in standby power mode.
— Requires that the server has CIMC firmware version 1.4(6) or later installed. There is a heartbeat LED on the top of the card that indicates when firmware is active.
— To use this card for UCS integration (Cisco UCS Manager mode) with Cisco UCS
Manager 2.1(0) or later, the minimum card-firmware and uboot image level is
2.1(0.306).
To help ensure that your operating system is compatible with the card you have selected, check the Hardware Compatibility List at this URL: http://www.cisco.com/en/US/products/ps10477/prod_technical_reference_list.html
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 25
CONFIGURING the SERVER
STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES
Copper twinax cables and SFP optical modules may be ordered to support the two-port network cards that are available with the server.
Choose Optional Twinax Cables
Table 9 lists the copper twinax cables available for the PCIe cards. You can choose cable lengths
of 1, 3, 5, 7, or 10 meters. The two longer cables (7 and 10 meters) are active, which means that they contain active components within the SFP+ housing to improve signal quality.
Table 9 Available Twinax Cables
Product ID (PID)
SFP-H10GB-CU1M
SFP-H10GB-CU3M
SFP-H10GB-CU5M
SFP-H10GB-ACU7M
SFP-H10GB-ACU10M
PID Description
10GBASE-CU SFP+ Cable (1 M)
10GBASE-CU SFP+ Cable (3 M)
10GBASE-CU SFP+ Cable (5 M)
10GBASE-CU SFP+ Cable (7 M)
10GBASE-CU SFP+ Cable (10 M)
Approved Configurations
(1) Choose Up to Two Twinax Cables for Each Network Card Ordered
■ You may choose one or two twinax cables for each compatible PCIe network card ordered.
The cables can be different lengths; however, you would normally order two cables of equal lengths to connect to the primary and redundant network switching equipment.
Choose Optional SFP Modules
Optical Cisco SFP+ modules are listed in Table 10 .
Table 10 Available SFP Modules
Product ID (PID)
SFP-10G-SR
DS-SFP-FC8G-SW
PID Description
10GBASE-SR SFP+ Module
850 nm, multimode, SR, 3.3V, LC connector, with Digital Optical Monitoring
8 Gbit SFP+ Module
850 nm, multimode, SR, 3.3V, LC connector, with Digital Optical Monitoring
26 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
CONFIGURING the SERVER
Approved Configurations
(1) Choose Up to Two SFP+ Modules for Each Network Card Ordered
■ You may choose one or two SFP+ optical modules cables for each compatible PCIe network card ordered. You would normally order two modules for connecting to the primary and redundant network switching equipment. With the SFP+ optical modules, you can use common fiber optic cables, widely available.
See the
for typical SFP+ and twinax connections to the network cards.
Caveats
Check the table on the following page for compatibility between the PCIe network cards and
SFPs or twinax cables.
NOTE: The table shows all PCIe network cards for all C-series servers. Not all of the cards shown in the table are supported in this server. The intent of the table is to show compatibility between cards and twinax cables or SFPs.
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 27
CONFIGURING the SERVER
Table 11 PCIe Card Compatibility
PCIe Cards
Converged Network Adapters (CNAs)
UCSC-PCIE-BSFP
(Broadcom 57712 Dual Port 10Gb SFP+ w/TOE iSCSI)
UCSC-PCIE-CSC-02
(Cisco VIC 1225 Dual Port 10Gb SFP+ CNA)
UCSC-PCIE-C10T-02
(Cisco VIC 1225T Dual Port 10GBaseT CNA)
UCSC-PCIE-C40Q-02
(Cisco VIC 1285 Dual Port 40Gb QSFP CNA)
UCSC-PCIE-C40Q-03
(Cisco VIC 1385 Dual Port 40Gb QSFP+ CNA w/RDMA)
UCSC-PCIE-ESFP
(Emulex OCe11102-FX dual-port 10 GbE FCoE CNA (Gen 3 CNA))
UCSC-PCIE-QSFP
(QLogic QLE8242-CU dual-port 10 GbE FCoE CNA)
UCSC-PCIE-B3SFP
(Broadcom 57810 10Gb A-FEX SFP+
UCSC-PCIE-Q8362
(Qlogic QLE8362 dual-port 10 GbE FCoE CNA)
UCSC-PCIE-E14102
(Emulex OCe14102-UX dual-port 10 GbE FCoE CNA)
Network Interface Cards (NICs)
N2XX-ABPCI01-M3
(Broadcom 5709 Dual-Port Ethernet PCIe Adapter for M3
Servers)
N2XX-ABPCI03-M3
(Broadcom 5709 Quad Port 10/100/1Gb NIC w/TOE iSCSI for M3
Servers
N2XX-AIPCI01
(Intel X520 Dual Port 10Gb SFP+ Adapter)
UCSC-PCIE-ITG
(Intel X540 Dual Port 10GBase-T Adapter)
UCSC-PCIE-IRJ45
(Intel i350 Quad Port 1Gb Adapter
UCSC-PCIE-BTG
(Broadcom 57712 Dual Port 10GBASE-T w/TOE iSCSI)
Host Bus Adapters (HBAs)
N2XX-AEPCI03
(Emulex LPe 11002 Dual Port 4Gb Fibre Channel HBA
N2XX-AEPCI05
(Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA)
N2XX-AQPCI03
(QLogic QLE2462 Dual Port 4Gb Fibre Channel HBA)
Twinax
Cables
Cisco SFP Modules
SFP-10G-SR DS-SFP-FC8G-SW
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
Yes
Yes
No
No
No
Yes
Yes
Yes
No
Use RJ45 Ethernet cable
No
Use RJ45 Ethernet cable
No
1
1
Use Qlogic SFP
Use Qlogic SFP
Use Intel SFP
No
No
No
No
No
No
No
No
No
No
No
Preinstalled - do not change SFP
Preinstalled - do not change SFP
Preinstalled - do not change SFP
28 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
CONFIGURING the SERVER
Table 11 PCIe Card Compatibility (continued)
PCIe Cards
N2XX-AQPCI05
(QLogic QLE2562 Dual Port 8Gb Fibre Channel HBA)
UCSC-PCIE-Q2672
(Qlogic QLE2672-CSC, 16Gb Fibre Channel HBA with SR Optics)
UCSC-PCIE-E16002
(Emulex LPe16002-M6, 16Gb Fibre Channel HBA with SR Optics)
Notes . . .
1. This card supports a 4x10 Gbps QSFP to SFP breakout fiber cable.
Twinax
Cables
Cisco SFP Modules
SFP-10G-SR DS-SFP-FC8G-SW
No Preinstalled - do not change SFP
No
No
Preinstalled - do not change SFP
Preinstalled - do not change SFP
Figure 5 Network Card Connections
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 29
CONFIGURING the SERVER
STEP 8 SELECT AC POWER CORD(s)
Using Table 12 , select the appropriate AC power cords. You can select a minimum of no power
cords and a maximum of two. If you select the option R2XX-DMYMPWRCORD, no power cord is shipped with the server.
Table 12 Available Power Cords
Product ID (PID) PID Description
R2XX-DMYMPWRCORD No power cord (dummy PID to allow for a no power cord option)
CAB-N5K6A-NA Power Cord, 200/240V 6A, North
America
Images
Not applicable
Plug: NEMA 6-15P
Cordset rating: 10 A, 250 V
Length: 8.2 ft
Connector:
IEC60320/C13
CAB-AC-L620-C13 AC Power Cord, NEMA L6-20 - C13,
2M/6.5ft
CAB-C13-CBN CABASY,WIRE,JUMPER CORD, 27" L,
C13/C14, 10A/250V
CAB-C13-C14-2M CABASY,WIRE,JUMPER CORD,PWR,
2 Meter, C13/C14, 10A/250V
CAB-C13-C14-AC CORD,PWR,JMP,IEC60320/C14,IEC6
0320/C13, 3.0M
30 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
CONFIGURING the SERVER
Table 12 Available Power Cords
Product ID (PID)
SFS-250V-10A-AR
CAB-9K10A-AU
PID Description
Power Cord, SFS, 250V, 10A,
Argentina
Power Cord, 250VAC 10A 3112 Plug,
Australia
Images
Plug:
EL 219
(IRAM 2073)
2500 mm
Cordset rating: 10 A, 250/500 V MAX
Length: 8.2 ft
Connector:
EL 701
(IEC60320/C13)
Plug:
EL 210
Cordset rating: 10 A, 250 V/500 V MAX
Length: 2500mm
Connector:
EL 701C
(EN 60320/C15)
(BS 1363A) 13 AMP fuse
SFS-250V-10A-CN Power Cord, SFS, 250V, 10A, China
Plug:
EL 218
(CCEE GB2009)
Cordset rating 10A, 250V
(2500 mm)
Connector:
EL 701
(IEC60320/C13)
CAB-250V-10A-CN AC Power Cord - 250V, 10A - PRC
CAB-9K10A-EU
SFS-250V-10A-ID
SFS-250V-10A-IS
Power Cord, 250VAC 10A CEE 7/7
Plug, EU
Power Cord, SFS, 250V, 10A, India
Plug:
EL 208
Power Cord, SFS, 250V, 10A, Israel
EL-212
16A
250V
Plug:
EL 212
(SI-32)
Plug:
M2511
Cordset rating: 10A/16 A, 250 V
Length: 8 ft 2 in. (2.5 m)
Connector:
VSCC15
Cordset rating 16A, 250V
(2500mm)
Connector:
EL 701
Cordset rating 10A, 250V/500V MAX
(2500 mm)
Connector:
EL 701B
(IEC60320/C13)
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 31
CONFIGURING the SERVER
Table 12 Available Power Cords
Product ID (PID)
CAB-9K10A-IT
PID Description
Power Cord, 250VAC 10A CEI
23-16/VII Plug, Italy
CAB-9K10A-SW
CAB-9K10A-UK
CAB-9K12A-NA
CAB-250V-10A-BR
CAB-JPN-3PIN
Images
Plug:
I/3G
(CEI 23-16)
Cordset rating: 10 A, 250 V
Length: 8 ft 2 in. (2.5 m)
Connector
C15M
(EN60320/C15 )
Power Cord, 250VAC 10A MP232
Plug, Switzerland
Plug:
MP232-R
Cordset rating: 10 A, 250 V
Length: 8 ft. 2 in (2.5 m)
Connector:
IEC 60320 C15
Power Cord, 250VAC 10A BS1363
Plug (13 A fuse), UK
Plug:
EL 210
Cordset rating: 10 A, 250 V/500 V MAX
Length: 2500mm
Connector:
EL 701C
(EN 60320/C15)
(BS 1363A) 13 AMP fuse
Power Cord, 125VAC 13A NEMA
5-15 Plug, North America
Power Cord - 250V, 10A - Brazil
Power Cord 3PIN, Japan
Cordset rating 13A, 125V
(8.2 feet) (2.5m)
Plug:
NEMA 5-15P
1
76.2 From Plug End
2,133.6 ± 25
Image not available
Connector:
IEC60320/C15
32 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
CONFIGURING the SERVER
STEP 9 ORDER POWER SUPPLY
The C22 M3 server accommodates one power supply. A lightly loaded server can operate from one 450 W power supply. A fully loaded server might need to be powered with a 650 W power supply (see
).
Prior to making a power supply selection, the UCS Power Calculator should be run to determine the right size power supply for your server configuration. A fully configured C22 M3 server may require the 650 W power supply. The UCS Power Calculator can be found at the following link: https://mainstayadvisor.com/Go/Cisco/Cisco-UCS-Power-Calculator.aspx
Table 13 Power Supply PIDs
Product ID (PID)
UCSC-PSU-450W
PID Description
450 W power supply
UCSC-PSU-650W 650 W power supply
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 33
CONFIGURING the SERVER
STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM
The reversible cable management arm mounts on either the right or left slide rails at the rear of the server and is used for cable management. Use
to order a cable management arm.
Table 14 Cable Management Arm
Product ID (PID)
UCSC-CMA1
PID Description
Cable Management Arm for C22 rack servers
NOTE: If you order and install a cable management arm, you will need the longest power cable available.
For more information about the cable management arm, see the Cisco UCS C22 M3 Installation
and Service Guide at this URL: http://www.cisco.com/en/US/docs/unified_computing/ucs/c/hw/C22/install/C22.pdf
34 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
CONFIGURING the SERVER
STEP 11 ORDER A TRUSTED PLATFORM MODULE
Trusted Platform Module (TPM) is a computer chip (microcontroller) that can securely store artifacts used to authenticate the platform (server). These artifacts can include passwords, certificates, or encryption keys. A TPM can also be used to store platform measurements that help ensure that the platform remains trustworthy. Authentication (ensuring that the platform can prove that it is what it claims to be) and attestation (a process helping to prove that a platform is trustworthy and has not been breached) are necessary steps to ensure safer computing in all environments.
The TPM ordering information is listed in Table 15 .
Table 15 Trusted Platform Module
Product ID (PID)
UCSX-TPM1-001
PID Description
Trusted Platform Module
NOTE: The module used in this server conforms to TPM v1.2/1.3, as defined by the
Trusted Computing Group (TCG). It is also SPI-based.
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 35
CONFIGURING the SERVER
STEP 12 ORDER OPTIONAL USB 2.0 DRIVE
You may order one optional USB 2.0 drive. One socket on the motherboard can accommodate an
8 or 16 GB drive.
The 8 or 16 GB drive (if ordered) is blank and comes installed on the motherboard. It can be used for a hypervisor or a license dongle.
The USB drive ordering information is listed in Table 16 .
Table 16 USB 2.0 Drive
Product ID (PID)
UCS-USBFLSHA-8GB
UCS-USBFLSHB-16GB
PID Description
8 GB Flash USB Drive for C22/C24
UCS Servers 16GB Flash USB Drive
See Figure 6 on page 48 for the location of the internal USB connector.
36 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
CONFIGURING the SERVER
STEP 13 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE
Several operating systems and value-added software programs are available. Select as desired
Table 17 OSs and Value-Added Software (for 2-CPU servers)
PID Description Product ID (PID)
Microsoft Windows Server
MSWS-08R2-STHV Windows Svr 2008 ST media R2 ST (1-4CPU, 5CAL)
MSWS-08R2-ENHV
MSWS-08R2-DCHV2S
Windows Svr 2008 EN media R2 EN (1-8CPU, 25CAL)
Windows Svr 2008 R2-2 CPU-Data Center
MSWS-12-ST2S
MSWS-12-DC2S
MSWS-12-ST2S-NS
MSWS-12-DC2S-NS
Windows Server 2012 Standard (2 CPU/2 VMs)
Windows Server 2012 Datacenter (2 CPU/Unlimited VMs)
Windows Server 2012 Standard (2 CPU/2 VMs) No Cisco SVC
Windows Server 2012 Datacenter (2 CPU/Unlim VM) No Cisco SVC
MSWS-12R2-ST2S
MSWS-12R2-DC2S
MSWS-12R2-ST2S-NS
MSWS-12R2-DC2S-NS
SUSE
SLES-SVR-2S-1G-1A
Windows Server 2012 R2 Standard (2 CPU/2 VMs)
Windows Server 2012 R2 Datacenter (2 CPU/Unlimited VMs)
Windows Server 2012 R2 Standard (2 CPU/2 VMs) No Cisco SVC
Windows Server 2012 R2 Datacen (2 CPU/Unlim VM) No Cisco Svc
SUSE Linux Enterprise Srvr (1-2 CPU,1 Phys);1yr Support Reqd
SLES-SVR-2S-1G-3A
SLES-SVR-2S-1G-5A
SLES-SVR-2S-UG-1A
SLES-SVR-2S-UG-3A
SLES-SVR-2S-UG-5A
SLES-SHA-2S-1A
SLES-SHA-2S-3A
SUSE Linux Enterprise Srvr (1-2 CPU,1 Phys);3yr Support Reqd
SUSE Linux Enterprise Srvr (1-2 CPU,1 Phys);5yr Support Reqd
SUSE Linux Enterprise Svr (1-2 CPU,Unl Vrt);1yr Support Reqd
SUSE Linux Enterprise Svr (1-2 CPU,Unl Vrt);3yr Support Reqd
SUSE Linux Enterprise Svr (1-2 CPU,Unl Vrt);5yr Support Reqd
SUSE Linux High Availability Ext (1-2 CPU); 1yr Support Reqd
SUSE Linux High Availability Ext (1-2 CPU); 3yr Support Reqd
SLES-SHA-2S-5A
SLES-HGC-2S-1A
SLES-HGC-2S-3A
SLES-HGC-2S-5A
SLES-SAP-2S-1G-1A
SLES-SAP-2S-1G-3A
SLES-SAP-2S-1G-5A
SLES-SAP-2S-UG-1A
SLES-SAP-2S-UG-3A
SLES-SAP-2S-UG-5A
SUSE Linux High Availability Ext (1-2 CPU); 5yr Support Reqd
SUSE Linux GEO Clustering for HA (1-2 CPU); 1yr Support Reqd
SUSE Linux GEO Clustering for HA (1-2 CPU); 3yr Support Reqd
SUSE Linux GEO Clustering for HA (1-2 CPU); 5yr Support Reqd
SLES for SAP Applications (1-2 CPU,1 Phys); 1yr Support Reqd
SLES for SAP Applications (1-2 CPU,1 Phys); 3yr Support Reqd
SLES for SAP Applications (1-2 CPU,1 Phys); 5yr Support Reqd
SLES for SAP Applications (1-2 CPU,Unl Vrt);1yr Support Reqd
SLES for SAP Applications (1-2 CPU,Unl Vrt);3yr Support Reqd
SLES for SAP Applications (1-2 CPU,Unl Vrt);5yr Support Reqd
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 37
CONFIGURING the SERVER
Table 17 OSs and Value-Added Software (for 2-CPU servers) (continued)
PID Description Product ID (PID)
Red Hat Enterprise Linux
RHEL-2S-1G-1A RHEL/2 Socket/1 Guest/1Yr Svcs Required
RHEL-2S-1G-3A RHEL/2 Socket/1 Guest/3Yr Svcs Required
RHEL-2S-4G-1A
RHEL-2S-4G-3A
RHEL/2 Socket/4 Guest/1Yr Svcs Required
RHEL/2 Socket/4 Guest/3Yr Svcs Required
RHEL-2S-UG-1A
RHEL-2S-UG-3A
RHEL-HA-2S-1A
RHEL-HA-2S-3A
RHEL-RS-2S-1A
RHEL/2 Socket/U Guest/1Yr Svcs Required
RHEL/2 Socket/U Guest/3Yr Svcs Required
RHEL Option/High-Availability/2 Socket/1Yr Svcs Required
RHEL Option/High-Availability/2 Socket/3Yr Svcs Required
RHEL Option/Resilient w/Ha /2 Socket/1 Yr Svcs Required
RHEL-RS-2S-3A
RHEL-SFS-2S-1A
RHEL-SFS-2S-3A
RHEL Option/Resilient Storage w/ HA /2 Socket/3 Yr Svcs Reqd
RHEL Option/Scalable File System/2 Socket/1 Yr Svcs Required
RHEL Option/Scalable File System/2 Socket/1 Yr Svcs Required
BMC
BMC-012
BMC-SE-4C
BMC-SE-6C
BMC-SE-8C
BMC-SE-10C
BMC-AE-4C
BMC BPPM Per Server
BMC BladeLogic Standard Edition, 4 Cores, Support Required
BMC BladeLogic Standard Edition, 6 Cores, Support Required
BMC BladeLogic Standard Edition, 8 Cores, Support Required
BMC BladeLogic Standard Edition, 10 Cores, Support Required
BMC BladeLogic Advanced Edition, 4 Cores, Support Required
BMC-AE-6C
BMC-AE-8C
BMC BladeLogic Advanced Edition, 6 Cores, Support Required
BMC BladeLogic Advanced Edition, 8 Cores, Support Required
BMC-AE-10C BMC BladeLogic Standard Edition, 10 Cores, Support Required
Nexus 1000V for Hyper-V and vSphere
N1K-VSG-UCS-BUN Over half off N1K and VSG w/ purchase of UCS B/C Series
N1K-VLEM-UCS-1
VSG-VLEM-UCS-1
UCS Director
CUIC-PHY-SERV-BM-U
Nexus 1000V License Paper Delivery (1 CPU) for bundles
VSG License Paper Delivery (1 CPU) for bundles
CUIC-PHY-SERV-U
CUIC-TERM
Cisco Cloupia Resource Lic - One Phy Server node bare metal
Cisco Cloupia Resource Lic - One physical Server node
Acceptance of Cisco Cloupia License Terms
38 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
CONFIGURING the SERVER
Table 17 OSs and Value-Added Software (for 2-CPU servers) (continued)
PID Description
VMware 5
VMW-VS5-STD-1A
VMW-VS5-STD-2A
VMW-VS5-STD-3A
VMW-VS5-STD-4A
VMW-VS5-STD-5A
VMW-VS5-ENT-1A
VMW-VS5-ENT-2A
VMW-VS5-ENT-3A
VMW-VS5-ENT-4A
VMW-VS5-ENT-5A
VMW-VS5-ENTP-1A
VMW-VS5-ENTP-2A
VMW-VS5-ENTP-3A
VMW-VS5-ENTP-4A
VMW-VS5-ENTP-5A
VMW-VC5-STD-1A
VMW-VC5-STD-2A
VMW-VC5-STD-3A
VMW-VC5-STD-4A
VMW-VC5-STD-5A
UCS-VMW-TERMS
Product ID (PID)
VMware vSphere 5 Standard for 1 Processor, 1 Year, Support Rqd
VMware vSphere 5 Standard for 1 Processor, 2 Year, Support Rqd
VMware vSphere 5 Standard for 1 Processor, 3 Year, Support Rqd
VMware vSphere 5 Standard for 1 Processor, 4 Year, Support Rqd
VMware vSphere 5 Standard for 1 Processor, 5 Year, Support Rqd
VMware vSphere 5 Enterprise for 1 Processor, 1 Year Support Rqd
VMware vSphere 5 Enterprise for 1 CPU, 2 Yr Support Rqd
VMware vSphere 5 Enterprise for 1 CPU, 3 Yr Support Rqd
VMware vSphere 5 Enterprise for 1 Processor, 4 Year Support Rqd
VMware vSphere 5 Enterprise for 1 CPU, 5 Yr Support Rqd
VMware vSphere 5 Enterprise Plus for 1 Processor, 1 Year Support Rqd
VMware vSphere 5 Enterprise Plus for 1 CPU, 2 Yr Support Rqd
VMware vSphere 5 Enterprise Plus for 1 Processor, 3 Year Support Rqd
VMware vSphere 5 Enterprise Plus for 1 Processor, 4 Year Support Rqd
VMware vSphere 5 Enterprise Plus for 1 Processor, 5 Year Support Rqd
VMware vCenter 5 Server Standard, 1 yr support required
VMware vCenter 5 Server Standard, 2 yr support required
VMware vCenter 5 Server Standard, 3 yr support required
VMware vCenter 5 Server Standard, 4 yr support required
VMware vCenter 5 Server Standard, 5 yr support required
Acceptance of Terms, Standalone VMW License for UCS Servers
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 39
CONFIGURING the SERVER
STEP 14 SELECT OPERATING SYSTEM MEDIA KIT
Select the optional operating system media listed in
.
Table 18 OS Media
Product ID (PID)
RHEL-6
SLES-11
MSWS-08R2-STHV-RM
MSWS-08R2-ENHV-RM
MSWS-08R2-DCHV-RM
MSWS-12-ST2S-RM
MSWS-12-DC2S-RM
MSWS-12R2-ST2S-RM
MSWS-12R2-DC2S-RM
PID Description
RHEL 6 Recovery Media Only (Multilingual)
SLES 11 media only (multilingual)
Windows Svr 2008 R2 ST (1-4CPU, 5CAL), Media
Windows Svr 2008 R2 EN (1-8CPU, 25CAL), Media
Windows Svr 2008 R2 DC (1-8CPU, 25CAL), Media
Windows Server 2012 Standard (2 CPU/2 VMs) Recovery Media
Windows Server 2012 Datacenter (2 CPU/Unlimited VM) Rec Media
Windows Server 2012 R2 Standard (2 CPU/2 VMs) Recovery Media
Windows Server 2012 R2 Datacen(2 CPU/Unlimited VM) Rec Media
40 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
CONFIGURING the SERVER
STEP 15 SELECT SERVICE and SUPPORT LEVEL
■
■
■
■
■
A variety of service options are available, as described in this section.
Unified Computing Warranty, No Contract
If you have noncritical implementations and choose to have no service contract, the following coverage is supplied:
Three-year parts coverage.
Next business day (NBD) onsite parts replacement eight hours a day, five days a week.
90-day software warranty on media.
Ongoing downloads of BIOS, drivers, and firmware updates.
UCSM updates for systems with Unified Computing System Manager. These updates include minor enhancements and bug fixes that are designed to maintain the compliance of UCSM with published specifications, release notes, and industry standards.
SMARTnet for UCS
For support of the entire Unified Computing System, Cisco offers the Cisco SMARTnet for UCS
Service. This service provides expert software and hardware support to help sustain performance and high availability of the unified computing environment. Access to Cisco
Technical Assistance Center (TAC) is provided around the clock, from anywhere in the world.
For UCS blade servers, there is Smart Call Home, which provides proactive, embedded diagnostics and real-time alerts. For systems that include Unified Computing System Manager, the support service includes downloads of UCSM upgrades. The Cisco SMARTnet for UCS Service includes flexible hardware replacement options, including replacement in as little as two hours.
There is also access to Cisco's extensive online technical resources to help maintain optimal efficiency and uptime of the unified computing environment. You can choose a desired service listed in
.
Table 19 Cisco SMARTnet for UCS Service
Product ID (PID)
CON-PREM-C22M3S
CON-OSP-C22M3S
CON-OSE-C22M3S
CON-OS-C22M3S
CON-S2P-C22M3S
CON-SNTP-C22M3S
CON-SNTE-C22M3S
CON-SNT-C22M3S
On Site? Description
Yes
No
No
Yes
Yes
Yes
No
No
ONSITE 24X7X2 UCS C22 M3 Server - SFF
ONSITE 24X7X4 UCS C22 M3 Server - SFF
ONSITE 8X5X4 UCS C22 M3 Server - SFF
ONSITE 8X5XNBD UCS C22 M3 Server - SFF
SMARTNET 24X7X2 UCS C22 M3 Server - SFF
SMARTNET 24X7X4 UCS C22 M3 Server - SFF
SMARTNET 8X5X4 UCS C22 M3 Server - SFF
SMARTNET 8X5XNBD UCS C22 M3 Server - SFF
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 41
CONFIGURING the SERVER
SMARTnet for UCS Hardware Only Service
For faster parts replacement than is provided with the standard Cisco Unified Computing System warranty, Cisco offers the Cisco SMARTnet for UCS Hardware Only Service. You can choose from two levels of advanced onsite parts replacement coverage in as little as four hours. SMARTnet for UCS Hardware Only Service provides remote access any time to Cisco support professionals who can determine if a return materials authorization (RMA) is required. You can choose a service listed in
Table 20 SMARTnet for UCS Hardware Only Service
Product ID (PID)
CON-UCW7-C22M3S
CON-UCW5-C22M3S
Service
Level GSP
UCW7
UCW5
On
Site?
Yes
Yes
Description
UC PLUS 24X7X4OS UCS C22 M3 Server - SFF
UC PLUS 8X5XNBDOS UCS C22 M3 Server - SFF
Unified Computing Partner Support Service
Cisco Partner Support Service (PSS) is a Cisco Collaborative Services service offering that is designed for partners to deliver their own branded support and managed services to enterprise customers. Cisco PSS provides partners with access to Cisco's support infrastructure and assets to help them:
■
■
■
Expand their service portfolios to support the most complex network environments
Lower delivery costs
Deliver services that increase customer loyalty
Partner Unified Computing Support Options enable eligible Cisco partners to develop and consistently deliver high-value technical support that capitalizes on Cisco intellectual assets.
This helps partners to realize higher margins and expand their practice.
PSS is available to all Cisco PSS partners, but requires additional specializations and requirements. For additional information, see the following URL: www.cisco.com/go/partnerucssupport
The two Partner Unified Computing Support Options include:
■
■
Partner Support Service for UCS
Partner Support Service for UCS Hardware Only
Partner Support Service for UCS provides hardware and software support, including triage support for third party software, backed by Cisco technical resources and level three support.
42 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
CONFIGURING the SERVER
.
Table 21 Partner Support Service for UCS
Product ID (PID)
CON-PSJ1-C22M3S
CON-PSJ2-C22M3S
CON-PSJ3-C22M3S
CON-PSJ4-C22M3S
Service
Level GSP
PSJ1
PSJ2
PSJ3
PSJ4
On
Site?
No
No
No
No
Description
UCS SUPP PSS 8X5XNBD UCS C22 M3 Server - SFF
UCS SUPP PSS 8X5X4 UCS C22 M3 Server - SFF
UCS SUPP PSS 24X7X4 UCS C22 M3 Server - SFF
UCS SUPP PSS 24X7X2 UCS C22 M3 Server - SFF
Partner Support Service for UCS Hardware Only provides customers with replacement parts in as
little as two hours. See Table 22
.
Table 22 Partner Support Service for UCS (Hardware Only)
Product ID (PID)
CON-PSW2-C22M3S
CON-PSW3-C22M3S
CON-PSW4-C22M3S
Service
Level GSP
PSW2
PSW3
PSW4
On
Site?
No
No
No
Description
UCS W PL PSS 8X5X4 UCS C22 M3 Server - SFF
UCS W PL PSS 24X7X4 UCS C22 M3 Server - SFF
UCS W PL PSS 24X7X2 UCS C22 M3 Server - SFF
Unified Computing Combined Support Service
■
■
■
■
Combined Services makes it easier to purchase and manage required services under one contract. SMARTnet services for UCS help increase the availability of your vital data center infrastructure and realize the most value from your unified computing investment. The more benefits you realize from the Cisco Unified Computing System (Cisco UCS), the more important the technology becomes to your business. These services allow you to:
■
Optimize the uptime, performance, and efficiency of your UCS
Protect your vital business applications by rapidly identifying and addressing issues
Strengthen in-house expertise through knowledge transfer and mentoring
Improve operational efficiency by allowing UCS experts to augment your internal staff resources
Enhance business agility by diagnosing potential issues before they affect your operations
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 43
CONFIGURING the SERVER
You can choose a service listed in
.
Table 23 UCS Computing Combined Support Service
Product ID (PID)
Service
Level GSP
On
Site?
Description
CON-NCF2C22M3S
CON-NCF2PC22M3S
NCF2
NCF2P
CON-NCF4PC22M3S NCF4P
CON-NCF4SC22M3S NCF4S
CON-NCFCSC22M3S NCFCS
CON-NCFEC22M3S NCFE
CON-NCFPC22M3S NCFP
CON-NCFTC22M3S NCFT
Yes
No
No
No
No
Yes
Yes
Yes
CMB SPT SVC 24X7X2 UCS C22 M3 Server - SFF
CMB SPT SVC 24X7X2OS
UCS C22 M3 Server - SFF
CMB SPT SVC 24X7X4OS
UCS C22 M3 Server - SFF
CMB SPT SVC 8X5X4OS
UCS C22 M3 Server - SFF
CMB SPT SVC 8X5XNBDOS
UCS C22 M3 Server - SFF
CMB SPT SVC 8X5X4
UCS C22 M3 Server - SFF
CMB SPT SVC 24X7X4 UCS C22 M3 Server - SFF
CMB SPT SVC 8X5XNBD
UCS C22 M3 Server - SFF
Unified Computing Drive Retention Service
With the Cisco Unified Computing Drive Retention (UCDR) Service, you can obtain a new disk drive in exchange for a faulty drive without returning the faulty drive. In exchange for a Cisco replacement drive, you provide a signed Certificate of Destruction (CoD) confirming that the drive has been removed from the system listed, is no longer in service, and has been destroyed.
Sophisticated data recovery techniques have made classified, proprietary, and confidential information vulnerable, even on malfunctioning disk drives. The UCDR service enables you to retain your drives and ensures that the sensitive data on those drives is not compromised, which reduces the risk of any potential liabilities. This service also enables you to comply with regulatory, local, and federal requirements.
If your company has a need to control confidential, classified, sensitive, or proprietary data, you
might want to consider one of the Drive Retention Services listed in Table 24 .
NOTE: Cisco does not offer a certified drive destruction service as part of this service.
Table 24 Drive Retention Service Options
Service Description
Service
Program Name
SMARTnet for UCS
Service with Drive
Retention
UCS DR
Service
Level GSP
UCSD7
UCSD7
Service Level
24x7x4 Onsite
8x5xNBD Onsite
Product ID (PID)
CON-UCSD7-C22M3S
CON-UCSD5-C22M3S
44 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
CONFIGURING the SERVER
Table 24 Drive Retention Service Options (continued)
Service Description
SMARTnet for UCS
HW ONLY+Drive
Retention
Service
Program Name
UCS HW+DR
Service
Level GSP
UCWD7
UCWD5
Service Level
24x7x4 Onsite
8x5xNBD Onsite
Product ID (PID)
CON-UCWD7-C22M3S
CON-UCWD5-C22M3S
For more service and support information, see the following URL: http://www.cisco.com/en/US/services/ps2961/ps10312/Unified_Computing_Services_Overview.pdf
For a complete listing of available services for Cisco Unified Computing System, see this URL: http://www.cisco.com/en/US/products/ps10312/serv_group_home.html
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 45
OPTIONAL STEP - ORDER RACK(s)
OPTIONAL STEP - ORDER RACK(s)
The optional R42610 rack is available from Cisco for the C-Series servers, including the C22 M3
SFF server. This rack is a standard 19-inch rack and can be ordered with a variety of options, as listed in
. Racks are shipped separately from the C22 M3 SFF server.
Table 25 Racks and Rack Options
Product ID (PID)
RACK-UCS 1
PID Description
Cisco R42610 expansion rack, no side panels
RACK-UCS2 1
RACK-BLANK-001
Cisco R42610 standard rack, w/side panels
Filler panels (qty 12), 1U, plastic, toolless
RACK-CBLMGT-001
RACK-CBLMGT-011
RACK-FASTEN-001
RACK-FASTEN-002
RACK-JOIN-001
Cable mgt D rings (qty 10), metal
Cable mgt straps (qty 10), Velcro
Mounting screws (qty 100), M6
Cage nuts (qty 50), M6
Rack joining kit
Notes . . .
1. Use these same base PIDs to order spare racks (available only as next-day replacements).
For more information about the R42610 rack, see RACKS, page 57 .
46 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
OPTIONAL STEP - ORDER PDU
OPTIONAL STEP - ORDER PDU
An optional power distribution unit (PDU) is available from Cisco for the C-Series rack servers, including theC22 M3 server. This PDU is available in a zero rack unit (RU) style (see
).
Table 26 PDU Options
Product ID (PID)
RP208-30-2P-U-2
PID Description
Zero RU PDU
For more information about the PDU, see PDUs, page 59 .
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 47
SUPPLEMENTAL MATERIAL
SUPPLEMENTAL MATERIAL
CHASSIS
Figure 6
An internal view of the C22 M3 chassis with the top cover removed is shown in
.
C22 M3 SFF With Top Cover Off
2 3 4 5 6 7
1
SYS FAN1
SYS FAN2
SYS FAN3
SYS FAN4
SYS FAN5
CPU 1
CPU 2
PCIe 1
PCIe 2
PSU 1
12
16 15
14
13
1
2
3
4
Drives
(hot-swappable, accessed through front panel)
Front panel operations board
Drive backplane
9
10
11
Cooling fans (five)
RTC battery on motherboard
12
PCIe riser 2 (PCIe slot 2)
Trusted platform module socket on motherboard (not visible under PCIe riser 2)
Power supply
(accessed through rear panel)
9
8
11
10
48 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
SUPPLEMENTAL MATERIAL
5 DIMM slots on motherboard (12)
6 CPU and heatsinks (2)
7 PCIe riser 1 (PCIe slot 1)
8 Internal USB 2.0 port
(on motherboard under PCIe riser 1)
13
14
15
16
Integrated SAS RAID connectors on motherboard
(left to right, SCU_Port 0, SCU_Port 1)
Software RAID 5 key header on motherboard
RAID SCU option ROM header on motherboard
Mounting point for SuperCap power module
(RAID backup unit)
CPUs and DIMMs
Physical Layout
Each CPU has three DIMM channels:
■
■
CPU1 has channels A, B, and C
CPU2 has channels D, E, and F
Each DIMM channel has two banks: Bank 1 and Bank 2. The blue-colored DIMM banks are for Bank 1 and the black-colored are for Bank 2.
As an example, DIMM slots A1, B1, and C1 belong to Bank 1, while A2, B2, and C2 belong to Bank 2.
top (channels A, B, and C) are associated with CPU 1, while the DIMM slots on the bottom (channels D, E, and F) are associated with CPU 2. Bank 1 slots (blue) are populated before Bank 2 slots (black).
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 49
SUPPLEMENTAL MATERIAL
Figure 7 Physical Layout of CPU DIMM Channels and Banks
A1
A2
B1
B2
C1
C2
CPU1
D1
D2
E1
E2
F1
F2
CPU2
50 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
SUPPLEMENTAL MATERIAL
Memory Population Rules
When considering the memory configuration of your server, you should consider the following items:
■
■
■
■
■
■
■
Each channel has two DIMM slots (for example, channel A = slots A1 and A2).
— Each channel can operate with one or two DIMMs installed.
— If a channel has only one DIMM, populate slot 1 first (the blue slot).
When both CPUs are installed, populate the DIMM slots of each CPU identically.
— Fill blue slots in the channels first: A1, D1, B1, E1, C1, F1
— Fill black slots in the channels second: A2, D2, B2, E2, C2, F2
Any DIMM installed in a DIMM socket for which the CPU is absent is not recognized.
For optimum performance, populate at least one DIMM per memory channel per CPU.
When populating DIMM slots, multiples of 6 DIMMs are best for achieving optimum performance, since there are 3 memory channels per CPU socket and 2 CPUs must be populated.
At 1 DPC and 2 DPC, 1600-MHz DIMMS will run at 1600 MHz (provided the CPU supports 1600
MHz DIMMs) and 1333-MHz DIMMs will run at 1333 MHz.
When mixing DIMMs, the following rules need to be followed:
— When mixing DIMMs of different densities (sizes), populate DIMMs with the highest density first. For example, if you have to mix 16 GB with 8 GB DIMMs, populate 16
GB DIMMs in blue slots (or bank 1) and then 8 GB in black slots (or bank 2).
— When mixing DIMMs with different ranks, populate DIMMs with the higher rank first.
For example, populate 16 GB 2R or 8 GB 2R before 4 GB 1R DIMMs.
— DIMMs of different sizes (4 GB, 8 GB, 16 GB) can be mixed within a channel. Total memory size in each single channel should be the same. For example, if you are mixing 4 GB and 8 GB DIMMs to achieve total 72 GB (6x8 GB + 6x4 GB) for a server, then populate blue slots with 8 GB DIMMs and black slots with 4 GB DIMMs and total memory size should be 12 GB for each of the 3 channels for both CPUs.
— When mixing DIMMs, all the DIMMs in the server must be the same speed.
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 51
SUPPLEMENTAL MATERIAL
Recommended Memory Population
This section explains the recommended DIMM population order rules for the C22 M3 server.
■
■
■
All DIMMs must be DDR3 DIMMs.
Mixing of Registered and Unbuffered DIMMs is not allowed per platform.
Do not mix 1333-MHz DIMMs with 1600-MHz DIMMs.
when populating DIMMs in the server.
Table 27 Recommended DIMM Population
CPU 1
Total
Memory
Size
48 GB 1
Blue Slots
Bank 1
(A1, B1, C1)
3 x 4 GB
Black Slots
Bank 2
(A2, B2, C2)
3 x 4 GB
3 x 8 GB —
72 GB 3 x 8 GB 3 x 4 GB
96 GB 2
120 GB
144 GB
192 GB
384 GB
3 x 8 GB
3 x 16 GB
3 x 16 GB
3 x 16 GB
3 x 16 GB
3 x 32 GB
3 x 8 GB
—
3 x 4 GB
3 x 8 GB
3 x 16 GB
3 x 32 GB
Blue Slots
Bank 1
(D1, E1, F1)
3 x 4 GB
CPU 2
Black Slots
Bank 2
(D2, E2, F2)
3 x 4 GB
3 x 8 GB
3 x 8 GB
3 x 8 GB
3 x 16 GB
3 x 16 GB
3 x 16 GB
3 x 16 GB
3 x 32 GB
—
3 x 4 GB
3 x 8 GB
—
3 x 4 GB
3 x 8 GB
3 x 16 GB
3 x 32 GB
Total DIMMs in
System
6
12
12
12
6
12
12
12
12
Notes . . .
1. For 48 GB, there are two possible sweet spot configurations:
6 x 8 GB occupies 1 DPC, so there is a possibility of increasing total memory size in the system (beyond 48 GB) by going to 2 DPC while still maintaining memory speed at 1600 MHz.
If there is no plan to increase total memory size in the system (beyond 48 GB), then 12 x 4GB is more price effective at this time.
2. For 96 GB, there are two possible optimal configurations:
6 x 16GB occupies 1 DPC, so there is a possibility of increasing total memory size in the system (beyond 96 GB) by going to 2 DPC while maintaining the maximum memory speed at 1600 MHz.
12 x 8GB gives the peak performance for this configuration and is recommended if there is no plan of increasing the total memory in the future.
52 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
SUPPLEMENTAL MATERIAL
Additional DIMM Populations
The list in Table 28 is not a complete list of all supported DIMM populations, but highlights common
configuration options.
Table 28 Supported DIMM Configurations
CPU 1 DIMMs
1 x 4 GB
2 x 4 GB
1 x 8 GB
3 x 4 GB
4 x 4 GB
2 x 8 GB
1 x 16 GB
5 x 4 GB
6 x 4 GB
3 x 8 GB
4 x 8 GB
2 x 16 GB
3 x 8 GB + 3 x 4 GB 1
5 x 8 GB
6 x 8 GB
3 x 16 GB
3 x 16 GB + 3 x 4 GB 3
4 x 16 GB
3 x 8 GB + 3 x 16 GB 5
5 x 16 GB
6 x 16 GB
6 x 32 GB
5
6
3
6
4
6
5
6
6
1
3
1
2
4
2
1
3
4
5
6
2
6
# CPU 1
DIMMs
CPU 1
Capacity
CPU 2 DIMMs
4 GB
8 GB
1 x 4 GB
2 x 4 GB
8 GB 1 x 8 GB
12 GB 3 x 4 GB
16 GB 4 x 4 GB
16 GB 2 x 8 GB
16 GB 1 x 16 GB
20 GB 5 x 4 GB
24GB 6 x 4 GB
24 GB 3 x 8 GB
32 GB 4 x 8 GB
32 GB 2 x 16 GB
36 GB 3 x 8 GB + 3 x 4 GB 2
40 GB 5 x 8 GB
48 GB 6 x 8 GB
48 GB 3 x 16 GB
60 GB 3 x 16 GB + 3 x 4 GB 4
64 GB 4 x 16 GB
72 GB 3 x 8 GB + 3 x 16 GB 6
80 GB 5 x 16 GB
96 GB 6 x 16 GB
192 GB 6 x 32 GB
5
6
3
6
4
6
5
6
6
20 GB
24GB
24 GB
32 GB
32 GB
36 GB
4 GB
8 GB
8 GB
12 GB
16 GB
16 GB
16 GB
40 GB
48 GB
48 GB
60 GB
64 GB
72 GB
80 GB
96 GB
192 GB
# CPU 2
DIMMs
CPU 2
Capacity
Total
DIMMs for both CPUs
Total
Capacity for 2 CPUs
1
3
1
2
4
2
1
3
4
5
6
2
6
2
4
2
6
8
4
2
10
12
6
8
4
12
10
12
6
12
8
12
10
12
12
8 GB
16 GB
16 GB
24 GB
32 GB
32 GB
32 GB
40 GB
48 GB
48 GB
64 GB
64 GB
72 GB
80 GB
96 GB
96 GB
120 GB
128 GB
144 GB
160 GB
192 GB
384 GB
Notes . . .
1. UCS-MR-1X082RY-A + UCS-MR-1X041RY-A
2. UCS-MR-1X082RY-A + UCS-MR-1X041RY-A
3. UCS-MR-1X162RY-A + UCS-MR-1X041RY-A
4. UCS-MR-1X162RY-A + UCS-MR-1X041RY-A
5. UCS-MR-1X082RY-A + UCS-MR-1X162RY-A
6. UCS-MR-1X082RY-A + UCS-MR-1X162RY-A
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 53
SUPPLEMENTAL MATERIAL
Low-Voltage DIMM Considerations
The C22 M3 server can be ordered with low-voltage (1.35 V) DIMMs only. Note the following considerations:
■
■
■
Low-voltage DIMMs within the server must have the identical manufacturer, type, speed, and size.
Low-voltage DIMMs and standard-voltage DIMMs can be mixed in the same server. Note that this causes the system BIOS to default to standard-voltage operation (Performance Mode).
That is, the server cannot operate in Power Saving Mode unless all DIMMs are low-voltage
DIMMs.
CPUs that have a maximum memory frequency less than 1333 MHz support low-voltage
DIMMs operating in Power Saving Mode only, and do not support Performance Mode.
54 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
SUPPLEMENTAL MATERIAL
RAID Summary
■
■
ROM5 and ROM55 embedded RAID upgrade options each support up to 8 drives.
The LSI MegaRAID SAS 9270CV-8i, 9240-8i, and 9220-8i RAID controller cards each support up to 8 drives
NOTE: If you do not select a PCIe RAID controller or one of the embedded RAID upgrade options (ROM5 or ROM55), you will have an embedded SATA-only RAID controller that supports up to four SATA-only drives (RAID 0, 1, 10).
for a summary of the supported RAID configuration options.
Table 29 Supported RAID Configurations
Server # CPUs
Embedded
RAID
Internal PCIe
RAID #1 1
Internal PCIe
RAID #2
# Drives
Supported
PCIe Slots
1 2
C22 M3 SFF
C22 M3 SFF
1
1
2
Not allowed
Enabled
Not allowed
Installed slot 1 (default) 3
Not allowed
Installed slot 2 (default)
Not allowed
Not allowed
Not allowed
Not allowed
8 internal
8 internal
8 internal
O
A
A
U
2 Enabled Not allowed 8 internal A
Notes . . .
1. If you want to boot from a device other than the 9270CV-8i, 9240-8i, or 9220-8i MegaRAID PCIe cards, you can leave the cards installed. Just disable the OPROM for their slots, and the system will boot even with the cards installed.
2. A = available slot, O = occupied slot, U = unsupported slot (slot 2 is not supported in 1-CPU systems)
3. The OPROM is enabled for the default PCIe RAID controller slots. If you want to enable a different slot, you must go into the BIOS and enable the OPROM for the desired slot and disable the OPROM for the default PCIe slot (see
).
A
U
O
2
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 55
SUPPLEMENTAL MATERIAL
RAID Option ROM (OPROM) Settings
The server contains an Option ROM (OPROM) for the PCIe slots. The server has a finite amount of option
ROM with which it can boot up devices. Go into the BIOS and disable the OPROM on the PCIe slots not used for booting so that resources are available for the slots that are used for booting. An example OPROM BIOS screen is shown in
.
Figure 8 Example BIOS Screen for OPROM
56 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
SUPPLEMENTAL MATERIAL
RACKS
The Cisco R42610 rack (see
Figure 9 ) is certified for Cisco UCS installation at customer sites and is suitable
for the following equipment:
■
■
Cisco UCS B-Series servers and fabric interconnects
Cisco UCS C-Series and select Nexus switches
The rack is compatible with hardware designed for EIA-standard 19-inch racks. Rack specifications are
Table 30 Cisco R42610 Rack Specifications
Parameter
Dimensions (H x W x D)
Dimensions (H x W x D) with packaging
Distance from front mounting rail to rear mounting rail
Weight
Weight with packaging
Side panels included
Equipment mounting capacity
Static load capacity
Standard Rack
78.74 x 24 x 43.38 in.
(2000 x 610 x 1102 mm)
89 x 33 x 47 in.
(2261 x 838 x 1194 mm)
29.2 in (741 mm)
299.83 lb (136 kg)
354 lb
(161 kg)
Yes
42RU
Dynamic load capacity
2100 lb
(954 kg)
Not applicable
Expansion Rack
78.74 x 23.58 x 43.38 in.
(2000 x 599 x 1102 mm)
89 x 33 x 47 in.
(2261 x 838 x 1194 mm)
29.2 in (741 mm)
231. 49 lb (105 kg)
284 lb
(129 kg)
No
42RU
2100 lb
(954 kg)
Not applicable
NOTE: The AC input connector is an IEC 320 C-14 15 A/250 VAC power inlet.
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 57
SUPPLEMENTAL MATERIAL
Figure 9 Cisco R42610 Rack
Front view - door closed Front view - door open Front view - door removed
58 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
SUPPLEMENTAL MATERIAL
PDUs
Cisco RP Series Power Distribution Units (PDUs) offer power distribution with branch circuit protection.
Cisco RP Series PDU models distribute power to up to 24 outlets. The architecture organizes power distribution, simplifies cable management, and enables you to move, add, and change rack equipment without an electrician.
With a Cisco RP Series PDU in the rack, you can replace up to two dozen input power cords with just one.
The fixed input cord connects to the power source from overhead or under-floor distribution. Your IT equipment is then powered by PDU outlets in the rack using short, easy-to-manage power cords.
The C-series severs accept the zero-rack-unit (0RU) PDU. See Figure 10 ).
Figure 10 Zero Rack Unit PDU (PID = RP208-30-2P-U-2)
1
2
Breakers
Ground connection
3
4
C13 plugs
C19 plugs
Cisco RP Series PDU models provide two 20-ampere (A) circuit breakers for groups of receptacles. The effects of a tripped circuit are limited to a receptacle group. Simply press a button to reset that circuit.
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 59
SUPPLEMENTAL MATERIAL
Motherboard USB Port
The C22 M3 SFF motherboard has one general-purpose USB socket as shown in Figure 11
.
Figure 11 Motherboard USB Port
SYS FAN1
SYS FAN2
SYS FAN3
SYS FAN4
SYS FAN5
CPU 1 PCIe 1
PCIe 2
CPU 2
PSU 1
1 Internal USB 2.0 port
(on motherboard under PCIe riser 1)
-
1
60 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
SUPPLEMENTAL MATERIAL
LED Indicators
The server contains LED indicators on the front and rear panels. Their functions are described in the following sections.
Front Panel
Figure 12 shows the front panel LEDs.
Figure 12 Front Panel LEDs
1 2 3 4 5 6 7 8 9
HDD01
HDD06
HDD02
HDD07
HDD03
HDD08
3
4
1
2
5
Power button/Power status LED
Identification button/LED
System status LED
Fan status LED
Temperature status LED
See
Table 31 for the functions of the front panel LEDs.
8
9
6
7
—
Power supply status LED
Network link activity LED
Hard drive fault LED
Hard drive activity LED
—
Table 31 Front Panel LEDs
LED
Power
(LED is integrated into power button)
LED State
Off
On (amber)
Unit ID
(LED is integrated into unit ID button)
On (green)
Off
On (blue)
Meaning
Server power is off
Server power is soft off (power is supplied only to the
CIMC and some motherboard functions)
Card power is on
Unit ID not active
Unit ID is activated
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 61
SUPPLEMENTAL MATERIAL
Table 31 Front Panel LEDs (continued)
LED
System Status
Fan Status
Temperature Status
Power Supply Status
Network Link Status
LED State
Off
On (green)
On (amber)
Blinking (amber)
Off
On (green)
On (amber)
Blinking (amber)
Off
On (green)
On (amber)
Blinking (amber)
Off
On (green)
On (amber)
Blinking (amber)
Off
On (green)
Meaning
Undefined
Server is in normal operating condition
Server is in a degraded operational state. For example:
■ Power supply redundancy is lost.
■ CPUs are mismatched.
■ At least one CPU is faulty.
■ At least one DIMM is faulty.
■ At least one drive in a RAID configuration failed.
Server is in a critical fault state. For example:
■ Boot failed.
■ Fatal CPU and/or bus error is detected.
■ Server is in over-temperature condition
Undefined
Fans are operating and no error condition has been detected
Fans are in a degraded operational state, indicating that one of the fans has a fault.
Critical fault state, indicating that two or more fans have a fault.
Undefined
System is operating at normal temperature and no error conditions have been detected.
One or more temperature sensors exceeded a warning threshold.
One or more temperature sensors exceeded a critical threshold
Undefined
AC power supplies are operating and no error condition has been detected.
One or more power supplies are in a degraded operational state.
One or more power supplies are in a critical fault state.
Undefined
Link pulses detected on any of the LOM ports, but no activity.
62 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
SUPPLEMENTAL MATERIAL
Table 31 Front Panel LEDs (continued)
LED
Hard Drive Fault
Hard Drive Activity
LED State
Blinking (green)
Off
On (amber)
Blinking (amber)
Off
On (green)
Blinking (green)
Rear Panel
Figure 13 shows the rear panel LEDs.
Figure 13 Rear Panel LEDs
Meaning
Activity on any of the LOM ports
The hard drive is operating properly
The hard drive has failed
The hard drive is rebuilding
There is no hard drive in the hard drive sled (no access, no fault)
The hard drive is ready
The hard drive is reading or writing data
PCIe 2 PCIe 1
PSU 1
1 2
3
4 6
5 7
1
2
3
4
Power supply fault LED
Power supply AC OK LED
1-Gb Ethernet link speed LED
1-Gb Ethernet link status LED
5
6
7
—
10/100/1000 Ethernet dedicated management link status LED
10/100/1000 Ethernet dedicated management link speed LED
Rear Identification button/LED
—
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 63
SUPPLEMENTAL MATERIAL
See
Table 32 for the functions of the rear panel LEDs.
Table 32 Rear Panel LEDs
LED
Power Supply Fault
LED State
Off
Blinking (amber)
Power Supply AC
1GbE Link Speed
1GbE Link Status
On (amber)
Off
Blinking (green)
On (green)
Off
On (amber)
On (green)
Off
On (green)
Meaning
The power supply is operating normally
An event warning threshold has been reached, but the power supply continues to operate
A critical fault threshold has been reached, causing the power supply to shut down (for example, a fan failure or an over-temperature condition).
There is no AC power to the power supply
AC power OK, DC output not enabled
AC power OK, DC outputs OK
Link Speed = 10 Mbps
Link Speed = 100 Mbps
Link Speed = 1 Gbps
No Link
Link is active
10/100/1000 Base-T
Link Status
10/100/1000 Base-T
Link Speed
Unit ID
(LED is integrated into unit ID button)
Blinking (green)
Off
On (green)
Blinking (green)
Off
On (amber)
On (green)
Off
On (blue)
Traffic is present on the active link
No Link
Link is active
Traffic is present on the active link
Link Speed = 10 Mbps
Link Speed = 100 Mbps
Link Speed = 1 Gbps
Unit ID not active
Unit ID is activated
64 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS
Dimensions and Weight
Table 33 UCS C22 M3 Dimensions and Weight
Parameter
Height
Width
Depth
Front Clearance
Side Clearance
Rear Clearance
Weight
Maximum (8 HDDs, 2 CPUs, 12 DIMMs, 1 power supply)
Bare (0 HDD, 0 CPU, 0 DIMM, no power supply)
Value
1.70 in (43.2 mm)
16.93 in.(430 mm)
26.0 in. (660.4 mm)
3 in. (76 mm)
1 in. (25 mm)
9 in. (233 mm)
27.78 lbs (12.6 kg)
23.48 lbs (10.65 kg)
Power Specifications
Table 34 UCS C22 M3 SFF 450 W Power Supply Specifications
Description
AC input voltage
AC input frequency
Maximum AC input current
Maximum AC inrush current
Maximum output power for the power supply
Power supply output voltage
Specification
90 to 264 VAC self-ranging
100 to 120 VAC nominal
200 to 240 VAC nominal
Range: 47 to 63 Hz (single phase, 50 to 60 Hz nominal)
6 A maximum at 100 VAC
3 A maximum at 208 VAC
9 A peak @ 35° C, 208 VAC
450 W
Power supply efficiency
Main power: 12 VDC
Standby power: 12 VDC
CSCI Platinum
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 65
TECHNICAL SPECIFICATIONS
NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet.
Table 35 UCS C22 M3 SFF 650 W Power Supply Specifications
Description
AC input voltage
AC input frequency
Maximum AC input current
Maximum AC inrush current
Maximum output power for the power supply
Power supply output voltage
Specification
90 to 264 VAC self-ranging,
100 to 120 VAC nominal
200 to 240 VAC nominal
Range: 47 to 63 Hz (single phase, 50 to 60 Hz nominal)
7.6 A maximum at 100 VAC
3.65 A maximum at 208 VAC
11 A peak @ 35° C, 208 VAC
650 W
Power supply efficiency
Main power: 12 VDC
Standby power: 12 VDC
CSCI Platinum
NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet.
For configuration-specific power specifications, use the Cisco UCS Power Calculator at this URL: https://mainstayadvisor.com/Go/Cisco/Cisco-UCS-Power-Calculator.aspx
66 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
TECHNICAL SPECIFICATIONS
Environmental Specifications
The power specifications for the C22 M3 server are listed in
Table 36 UCS C22 M3 Environmental Specifications
Parameter
Temperature operating
Minimum
41 to 95° F (5 to 35° C) Maximum temperature is to be derated by 1 degree C for every 305 m (1000 ft.) of altitude above sea level
–40 to 149°F (–40 to 65°C)
10 to 90%
Temperature nonoperating
Humidity (RH) nonoperating, non-condensing
Altitude operating
Altitude nonoperating
Sound Power level, Measure
A-weighted per ISO7779 LWAd (Bels)
Operation at 73°F (23°C)
Sound Pressure level, Measure
A-weighted per ISO7779 LpAm (dBA)
Operation at 73°F (23°C)
0 to 3,000 m (0 to 10,000 ft.)
0 to 12,192 m (0 to 40,000 ft.)
5.9
46
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 67
TECHNICAL SPECIFICATIONS
Compliance Requirements
The regulatory compliance requirements for C-Series servers are listed in
.
Table 37 UCS C-Series Regulatory Compliance Requirements
Parameter
Regulatory Compliance
Safety
EMC - Emissions
EMC - Immunity
Description
Products should comply with CE Markings per directives
2004/108/EC and 2006/95/EC
UL 60950-1 Second Edition
CAN/CSA-C22.2 No. 60950-1 Second Edition
EN 60950-1 Second Edition
IEC 60950-1 Second Edition
AS/NZS 60950-1
GB4943 2001
47CFR Part 15 (CFR 47) Class A
AS/NZS CISPR22 Class A
CISPR22 Class A
EN55022 Class A
ICES003 Class A
VCCI Class A
EN61000-3-2
EN61000-3-3
KN22 Class A
CNS13438 Class A
EN55024
CISPR24
EN300386
KN24
68 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 3 OVERVIEW
- 4 DETAILED VIEWS
- 4 Chassis Front View
- 5 Chassis Rear View
- 6 BASE SERVER STANDARD CAPABILITIES and FEATURES
- 9 CONFIGURING the SERVER
- 46 OPTIONAL STEP - ORDER RACK(s)
- 47 OPTIONAL STEP - ORDER PDU
- 48 SUPPLEMENTAL MATERIAL
- 48 CHASSIS
- 49 CPUs and DIMMs
- 49 Physical Layout
- 51 Memory Population Rules
- 52 Recommended Memory Population
- 53 Additional DIMM Populations
- 54 Low-Voltage DIMM Considerations
- 55 RAID Summary
- 56 RAID Option ROM (OPROM) Settings
- 57 RACKS
- 59 PDUs
- 60 Motherboard USB Port
- 61 LED Indicators
- 61 Front Panel
- 63 Rear Panel
- 65 TECHNICAL SPECIFICATIONS
- 65 Dimensions and Weight
- 65 Power Specifications
- 67 Environmental Specifications
- 68 Compliance Requirements