Fire Alarm Cables
Life. Safety . Fire alarm systems serve as life lines to safe and secure buildings.
As one of the original manufacturers of fire alarm cable, West Penn Wire knows proper cable selection is critical to effective system performance. With over 100 variations of cable constructions, environmental ratings, colors, and striping options, we have the right fire alarm cable. Match the right cable to system demand and ensure a safe building.
B
B
A
C
C
A
A
FEATURES
• Solid Conductor Constructions
• Stranded Conductor Constructions
• Power Limited Data Grade Designs
• Available in Multiple Jacket Colors
• Avialable with Strips
• Circuit Integrity Designs
• Local Law 5 (NYC) Designs
• Indoor/Outdoor Design in Aquaseal Section-
WEST PENN WIRE CABLE WITH CONFIDENCE
Fire Alarm Cables
AWG
Size
# of
Cond.
12 Solid 2
14 Solid 2
14 Solid
16 Solid
16 Solid
18 Solid
18 Solid
12 Strd
14 Strd
14 Strd
16 Strd
16 Strd
18 Strd
18 Strd
4
2
4
2
4
4
2
2
4
2
4
2
UNSHIELDED FIRE ALARM CABLES
FPL FPLR FPLP NPLF NPLFP FPLR-CIC FPLR-CI
Aquaseal Low Cap Parallel Mid-Cap Mid-Cap Mid-Cap Mid-Cap Mid-Cap Mid-Cap
AQ227
AQ226
AQ246
AQ225
AQ245
AQ224
AQ244
D990
D980
D982
974
972
971
970
998
994
700
990
992
980
982
998S
994S
990S
60995B 5020UZ 5020UM
60993B 1994 251994 5120UZ 5120UM
60700B
60991B 1990
60164B
5220UZ
5122UM
5220UM
5222UM
60980B
60992B
251980 5320UM
5322UM
5000UZ
5100UZ
5200UZ
AWG
Size
12 Solid
12 Solid
14 Solid
14 Solid
16 Solid
16 Solid
18 Solid
18 Solid
12 Strd
14 Strd
14 Strd
16 Strd
16 Strd
18 Strd
18 Strd
2
4
2
4
2
4
2
4
2
4
2
# of
Cond.
2
4
2
4
FPL
SHIELDED FIRE ALARM CABLES
FPLR FPLP NPLF NPLFP FPLR-CIC FPLR-CI
Aquaseal Low Cap Mid-Cap Mid-Cap Low-Cap Mid-Cap Mid-Cap Mid-Cap Mid-Cap
AQ296
AQ295
D995
D991
D975
999
995
60994B
60992B
1999 5020FZ 5020FM
5022FZ 5022FM
1995 251995 5120FZ 5120FM
1997 5122FM
60990B D60990 1991 251991 5220FZ 5220FM 991
993 603164B
975 60975B D60975 1975 251975
977 60977B
5222FZ 5222FM
5320FM
5322FM
5000FZ
5100FZ 5100FM
5200FZ
5200FM AQ294
AQ3245
AQ293
AQ3244
5300FM
CABLE WITH CONFIDENCE WEST PENN WIRE
FIRE ALARM SYSTEMS AND CABLE:
West Penn Wire is the leading manufacturer of fire alarm system cables for the fire protection industry.Our innovative product line includes all power-limited and non-power limited cables for use in the NECArticle 760.West Penn Wire includes Aquaseal power-limited fire alarm system cables.AquasealWater-Resistant cable is a trademark for the industries original indoor/outdoor low-capacitance fire alarmsystem cables.
NATIONAL ELECTRIC CODE (NEC) ARTICLE 760:NEC Article 760 covers the installation of wiring and equipment of fire alarm systems, including all circutis controlled and powered by the fire alarm system.These systems are defined in the
NEC as “Theportion of the wiring system between the load side of the overcurrent devices or the power-limited supplyand the connected equipment of all circuits powered and controlled by the fire alarm system.”
POWER-LIMITED FIRE ALARM SYSTEM CABLES:
Three types of power-limited fire alarm cables are currently in use.
1.Type FPL- FPL power-limited fire alarm cable is listed by the NEC as being suitable for general purpose fire alarm use.This listing excludes installation in riser, ducts, plenums and other spaceused for environmental air unless the cable is installed in conduit.All FPL cables are listed as being resistant to the spread of fire and must pass both UL test 1424 and the vertical flame testUL 1581.
2.Type FPLR- FPLR power-limited fire alarm riser cable is listed as being suitable for use in a vertical run in a shaft or from floor to floor.All FPLR cables are listed as having fire-resistantcharacteristics capable of preventing fire from traveling from floor to floor.Riser cables must pass both UL test 1424 and the Vertical riser test UL 1666.
3.Type FPLP- FPLP power-limited fire alarm cable is listed by the NEC as being suitable for usein ducts, plenums and other space used for environmental air.All FPLP cable are listed as having adequate fire resistant and low-smokeproducing characteristics and must pass bothUL test 1424 and UL Stiener tunnel test 910. (NFPA262)
• No Voltage Rating Markings on PLFA Cables
• CL3 and CM rated cables, which have a voltage rating of 300V are permitted to be usedas
PLFA cables.
• Power-limited is inherently limited by the power supply
• Transformer
• Other Power Supply Devices
NON POWER-LIMITED FIRE ALARM SYSTEM CABLES:
1.Type NPLF- NPLF Non power-limited fire alarm cable is listed by the NEC as being suitable for general purpose fire alarm use.This listing excludes installation in riser, ducts, plenums and other space used for environmental air unless the cable is installed in conduit.All NFPL cables are listed as being resistant to the spread of fire and must pass both UL test
1424 and the verticalflame test UL 1581.
2.Type NPLFP- NPLFP Non power-limited fire alarm cable is listed by the NEC as being suitable for use in ducts, plenums and other space used for environmental air.All NPLFP cable are listed as having adequate fire resistant and low-smokeproducing characteristics and must pass bothUL test 1424 and UL Stiener tunnel test 910.(NFPA262)
• Power source of NPLFA circuits output voltage shall not exceed 600 volts.Nominal
• Marking on NPLF cables are not addressed as 150V.For use in 150V or less on NPLF circuits( out of tray or conduit)
• Class 1 cables can be installed and used as NPLFA, but must be placed in a tray or conduit.• Overcurrent devices shall be located at the point where the device to be protected receives its supply.
WEST PENN WIRE CABLE WITH CONFIDENCE
CONVENTIONAL ( STANDARD) FIRE ALARM SYSTEM
Conventional Fire Alarm Systems, in their various forms, have been around for many of years and havechanged little in that time in terms of technology although design and reliability have impovedsignificantly.However, Conventional systems are a well proven technology protecting many hundreds ofthousands of properties worldwide. A Conventional
Fire Alarm System is often the natural choice forsmaller systems or where budget constraints exist.
In a Conventional Fire Alarm System the “Intelligence”of the system resides solely within the Fire AlarmControl Panel.The
panel receives a trigger signal from a Conventional Detector or Initiating DeviceCircuit (Smoke, heat, flame detectors) which in turn signals the condition to the Notification (Indicating)Device Circuit such as alarm sounders, horns, strobes and other remote signalling equipment.
Conventional detectors are normally connected to the Fire Control Panel via dedicated circuits, each circuit protecting a designated “Zone”or area of the building.The system has different modes:Normal,Alarm, Trouble, and others, depending on the Fire Alarm Manufacturer.
Zone 1
Zone 2 Initiating
Zone 3 Devices
Notification
Devices
FACP
CONVENTIONAL FIRE ALARM CABLE SELECTION
The designer must be sure that the last device on the circuit has sufficient voltage to operate the devicewithin its rated voltage.When calculating the voltage available to the last device, it is necessary to ocon-sider the voltage drop due to the resistance of the wire.The larger the wire, the less the voltage drop.Generally, for purposes of determining the wire size necessary for the system, it is best to consider all ofthe devices as “lumped”on the end of the supply circuit, this simulates the worst case.
Typical wire size resistance:
18 AWG solid: Approximately
16 AWG solid: Approximately
14 AWG solid: Approximately
12 AWG solid: Approximately
6.5ohms/1000ft.
4.1ohms/1000ft.
2.6ohms/1000ft.
1.8ohms/1000ft.
Loop Resistance
13ohms/1000ft.
8.2ohms/1000ft.
5.2ohms/1000ft.
3.6ohms/1000ft.
EXAMPLE:
Assume you have 10 devices on a zone and each require 50mA average and 2000ft.of 14 AWG wiring.The voltage drop at the end of the loop is .050 amps per device x 10 devices x 2.6?/1000ft x 2000 = 2.6 V.A 12 AWG would produce a drop 1.8 V, and a 18 AWG would produce a voltage drop of 6.5 V.
Notes:
• If Class A wiring is installed, the wire length may be up to 4 times the single wire length in this calculation• Consult your panel manufacturer’s specifications to determine acceptable voltage drop.Do not exceed panels specifiedamperage output• All wiring must be installed in compliance with the National Electrical Code (NEC) and applicable local codes, as well as special requirements of the authority having jurisdiction, using the proper wire size.
CABLE WITH CONFIDENCE WEST PENN WIRE
CONVENTIONAL FIRE ALARM SYSTEM CABLES
(POWER-LIMITED) CONVENTIONAL FIRE ALARM SYSTEM CABLES:
CONDUCTOR-
• Shall not be smaller in size than a 26 AWG.
• Single conductor no smaller than 18 AWG.
• Solid or Stranded conductor.Bare Copper for lower DCResistance.
INSULATION (DIELECTRIC)-
• PVC Insulation for the FPLR cables
• Fire/ Smoke Retardant PVC for the FPLP - West PennWire “B”Series
• Flouropolymer Insulation for the FPLP - Non “B”Series.
CONDUCTORS ARE EITHER TWISTED CABLED OR PARALLEL.
SHIELD-
(OPTIONAL) DEPENDANT ON SYSTEM REQUIREMENTS, AND ENVIRONMENTAL CONDITIONS -
• To protect against interference created from other cables or other electronic/electrIcal/ Mechanical devices.
• The shield is a 100% Aluminium foiled wrap.
JACKET-
PVC Jacket for the FPLR cables
• Flexible Plenum PVCjacket for the FPLP cables.
• The jacket is usually Red
(NON POWER-LIMITED) CONVENTIONAL FIRE ALARM SYSTEM
CABLES:
CONDUCTOR-
• 18 AWG or smaller AWG ( larger conductor)
• Solid or stranded Bare copper
INSULATION (DIELECTRIC)-
• PVC with Nylon coating • NPLF cables (Nylon for dielectric stregth)
• Flouropolymer insulation - NPLFP cablesCONDUCTORS ARE CABLED.
SHIELD-
(OPTIONAL) DEPENDANT ON SYSTEM REQUIREMENTS, AND ENVIRONMENTAL CONDITIONS
• To protect against interference created from other cables or other electronic/electrIcal/ Mechanical devices.
• The shield is a 100% Aluminium foiled wrap.
JACKET-
PVC Jacket for the NPLF cables
• Flouropolymer jacket - NPLFP cables
• Color is usually red.
WEST PENN WIRE CABLE WITH CONFIDENCE
ADDRESSABLE FIRE ALARM SYSTEM
Addressable Fire Alarm Systems differ from conventional systems in a number of ways and certainly addmore flexibility, intelligence, speed of identification and scope of control.For this reason, Addressable Fire Alarm Systems are the natural choice for larger premises and buildings with morecomplex system requirements.
In an Addressable system, detectors are wired in a loop around the building with each detector havingits own unique address.The system may contain one or more loops depending upon the size of the sys-tem and design requirements.The Fire Control Panel communicates with each detector individually andreceives a status report e.g Normal, Alarm, Trouble etc.As each detector has an individual address thefire alarm control panel is able to display or indicate the precise location of the device in question, whichobviously helps speed the location of an incident and for this reason zoning of the system is not neces-sary, although it may be done for convenience.
Addressable detectors are, in themselves, intelligent devices which are capable of reporting far morethan just fire or fault conditions.Most analog addressable detectors are able to signal if contamination inthe device reaches a pre-set level enabling maintenance to take place prior to problems being experienced.
In most earlier styles of Addressable systems, the notification appliances were not intellegent.Today,many manufacturers are providing addressable notification technology.There are many advantages ofproviding such technology.Such as lower cost of wire, and overall installation time.
Addressable initiating device loop
Notification
Devices
FACP
ADDRESSABLE FIRE ALARM CABLE SELECTION
The designer must be aware of not only the D.C Resistance of the cable, but the capacitance and theVelocity of proporgation of the cable.The designer must assure that the overall loop capacitance is notcompromised, and error rates are kept to a minimum.
Nominal Capacitance for wire sizes:
18 AWG solid unshielded: 16pf/ft
18 AWG solid shielded: 25pf/f t45pf/ft **
16 AWG solid unshielded: 18pf/ft
16 AWG solid shielded: 30pf/ft 54pf/ft **
14 AWG solid shielded: 30pf/ft. 54pf/ft **
12 AWG solid shielded: 35pf/ft. 63pf/ft ****
Capacitance between one conductor and the other connected to the shield.
Notes:
• If Class A wiring is installed, the wire length may be up to 4 times the single wire length in this calculation
• Consult your panel manufacturer’s specifications to determine acceptable loop capacitance.• All wiring must be installed in compliance with the National Electrical Code (NEC) and applicable local codes, as well as special requirements of the authority having jurisdiction, using the proper wire size.
CABLE WITH CONFIDENCE WEST PENN WIRE
LOW AND MID CAPACITANCE CABLES:
ADDRESSABLE FIRE ALARM SYSTEM
The need to conform to the American with Disability Act (ADA), and the increased demand for addressable fire-alarm systems have created many changes in the fire-alarm cable constructions.An addressable system allows the control panel or unit to communicate with each base individuallyusing a sophisticated polling process.The polling process allows the system to detect trouble, or alarmor each base initiating devices, and in some cases the notification devices.Addressable fire-alarm signals need to be fast and have a clear signal transfer.Hence the electricalcharacteristics are a major concern in cable construction
Input
Signal
Output
Minimal capacitance change
Small capacitance change
Large capacitance change
Capacitance-
The property of a system of conductors and dielectrics that allow the storage of an electrical charge when a potential difference exists between conductors.Capacitance is found betweenwo wires of a twisted pair, and also between adjacent conductors in the same cable (mutual capaci-ance).Capacitance is expressed in pf/ft.The larger the capacitance, the higher the distortions.
Velocity of propogation-refers to a ratio of a signal traveling through a cable compared to that samesignal traveling through air and is determined by the dielectric insulation material.
(POWER-LIMITED) ADDRESSABLE FIRE ALARM SYSTEM CABLES:
CONDUCTOR
• Shall not be smaller in size than a 26 AWG.
• Single conductor no smaller than 18 AWG.
• Solid or Stranded conductor.Bare Copper for lower DC Resistance.
• West Penn Wire 12 AWG up to 18 AWG.
INSULATION (DIELECTRIC)
• COPOLENE Insulation for the FPL cables.
• Thicker than conventional fire system cable insulation
• A better performance dielectric material
• Flouropolymer Insulation for the FPLP CablesTWISTED CABLE CONSTRUCTION.
SHIELD-
(OPTIONAL) DEPENDANT ON SYSTEM REQUIREMENTS, AND ENVIRONMENTAL
CONDITIONS.
• To protect against interference created from other cables or other electronic/electrical/
Mechanical devices.
• The shield is a 100% Aluminium foiled wrap.JACKET
• PVC Jacket for the FPL cables• Flexible Plenum PVCjacket for the FPLP cables.
CABLE WITH CONFIDENCE WEST PENN WIRE
AQUASEAL WATER RESISTANT CABLE
Aquaseal Power-limited water-resistant cables are designed to be used for indoor/outdoor fire alarm sys-tem.The
Aquaseal products are manufactured using a premium grade jacket compound.These cablesare flame retardant, sunlight and water resistant, and employ an abrasion and crush resistant construction.This durability allows the Aquaseal power-limited water-resistant cables to be direct burial.
The internal cable construction employs a dry water blocking barrier instead of a messy gel.Unlikemany other outdoor cables which can not be placed indoors due to their inability to pass flame tests.Aquaseal water-resistant cables carry both indoor and outdoor ratings.
Aquaseal cable retains consistent electrical characteristics compared to standard cable when immersedin water.The
moisture blocking barrier used in this cable has proven itself in various tests where stan-dard outdoor cable has failed.This can be verified by monitoring the capacitance levels of both cables.Aquaseal water-resistant cables will consistently have lower capacitance values and remain stable overthe long haul enabling the lowest signal loss.
Aquaseal is UL listed NEC type FPL or PLTC rated and utilizing 18 AWG to 12 AWG makes this cableexcellent for low voltage Conventional and Addressable systems.
D
+ + -
+ - +
D
E
Aquaseal Water Resistant Cables
Power-Limited - Fire Alarm (FPL)
Pgs. 43-44 E
Aquaseal Water Resistant Cables
Communication Cables (CM)
Pgs. 38-42
D
Bulk Cable | FIRE ALARM
Unshielded | FPLR
Power-Limited
Features:
• Mid-Capacitance Performance
• Solid Conductors
• Riser Rated UL Listed - UL1666
• Meets 300V requirements specified by NEC
WEST PENN WIRE
Applications:
Indoor for:
• Initiating Devices
• Signal Line Circuits
• Notification Devices
• Control Circuts
• Audio Circuits
Catalog
No.
980
982
990
992
994
700
998
No. of
Conductors
Cond.
Type &
Nom. DCR
1
Pair
4
1
Pair
4
1
Pair
18 AWG
Solid
6.5Ω/Mft
18 AWG
Solid
6.5Ω/Mft
16 AWG
Solid
4.1Ω/Mft
16 AWG
Solid
4.1Ω/Mft
14 AWG
Solid
2.6Ω/Mft
Insulation
Type &
Thickness
Inches
PP*
.007
PP*
.007
PP*
.007
PP*
.007
PP*
.010
4
1
Pair
14 AWG
Solid
2.6Ω/Mft
12 AWG
Solid
1.8Ω/Mft
PP*
.010
PP*
.010
Shielding
None
None
None
None
None
None
None
Jacket
Type &
Thickness
Inches
PVC
.017
PVC
.017
Nom. O.D
Inches
.146
.170
PVC
.017
PVC
.017
PVC
.017
PVC
.017
PVC
.017
.168
.198
.210
.246
.244
Special Notes:
• Selected Plenum Versions see page
• Selected Indoor/Outdoor Versions see Aquaseal
• Select items are packaged in our Advantage Box.
• PP* - Polypropylene
• Rip Cord
• Spools Size - Standard 1000ft Put-ups
• Tracer markings available upon request
NEC
Type
Nom.
Capacitance
FPLR
FPLR
FPLR
FPLR
FPLR
FPLR
FPLR
20 pf/ft
20 pf/ft
23 pf/ft
23 pf/ft
22 pf/ft
22 pf/ft
23 pf/ft
Jacket
Colors
RD, BL,WH,YE
RD, BL,WH,YE
RD, BL,WH,YE
RD
RD, BL,WH,YE
RD
RD
2 www.westpenn-wpw.com | 800-245-4964 | Specifications subject to change | WEST PENN WIRE
Bulk Cable | F IRE ALARM
Power-Limited- PLENECON II WEST PENN WIRE
Unshielded | FPLP Features:
• Mid-Capacitance Performance
• Solid Conductors
• Riser Rated UL Listed - NFPA-262 Smoke/Flame
• Meets 300V requirements specified by NEC
Applications:
Indoor for:
• Initiating Devices
• Signal Line Circuits
• Notification Devices
• Control Circuts
• Audio Circuits
Catalog
No.
60980B
60982B
60991B
60164B
60993B
60700B
60995B
No. of
Conductors
Cond.
Type &
Nom. DCR
Insulation
Type &
Thickness
Inches
Shielding
1
Pair
4
1
Pair
4
1
Pair
4
1
Pair
18 AWG
Solid
6.5Ω/Mft
18 AWG
Solid
6.5Ω/Mft
16 AWG
Solid
4.1Ω/Mft
16 AWG
Solid
4.1Ω/Mft
14 AWG
Solid
2.6Ω/Mft
14 AWG
Solid
2.6Ω/Mft
12 AWG
Solid
1.8Ω/Mft
.008
.008
.008
.008
.010
.010
.010
None
None
None
None
None
None
None
Jacket
Type &
Thickness
Inches
Plenum PVC
.015
Plenum PVC
.015
Plenum PVC
.015
Plenum PVC
.015
Plenum PVC
.015
Plenum PVC
.015
Plenum PVC
.015
Nom. O.D
Inches
.144
.166
.164
.191
.198
.236
.239
NEC
Type
Nom.
Capacitance
FPLP
FPLP
FPLP
FPLP
FPLP
FPLP
FPLP
31 pf/ft
31 pf/ft
33 pf/ft
33 pf/ft
34 pf/ft
34 pf/ft
40 pf/ft
Jacket
Colors
RD
RD
RD, BL,
OR,WH,YE
RD
RD, BL,YE
RD
RD
Special Notes:
• Selected Plenum Versions see page
• Select items are packaged in our Advantage Box.
• PP* - Polypropylene
• Rip Cord
• Spools Size - Standard 1000ft Put-ups
• Tracer markings available upon request www.westpenn-wpw.com | 800-245-4964 | Specifications subject to change | WEST PENN WIRE
3
Bulk Cable | FIRE ALARM
Unshielded | FPLR
Stranded Conductors
Features:
• Mid-Capacitance Performance
• Stranded Conductors for Flex Installations
• Riser Rated UL Listed - UL1666
• Meets 300V requirements specified by NEC
WEST PENN WIRE
Applications:
Indoor for:
• Initiating Devices
• Signal Line Circuits
• Notification Devices
• Control Circuts
• Audio Circuits
Catalog
No.
990S
994S
998S
No. of
Conductors
Cond.
Type &
Nom. DCR
Insulation
Type &
Thickness
Inches
1 Pair
16 AWG
Strd
4.1Ω/Mft
PP*
.009
1 Pair
1 Pair
14 AWG
Strd
2.6Ω/Mft
12 AWG
Strd
1.8Ω/Mft
PP*
.010
PP*
.010
Shielding
None
None
None
Jacket
Type &
Thickness
Inches
PVC
.017
Nom. O.D
Inches
.182
PVC
.017
PVC
.017
.224
.260
NEC
Type
Nom.
Capacitance
FPLR
FPLR
FPLR
19 pf/ft
24 pf/ft
24 pf/ft
Jacket
Colors
RD
RD
RD
Unshielded | FPLP Features:
• Mid-Capacitance Performance
• Stranded Conductors for Flex Installations
• Plenum Rated - UL Listed NFPA262
• Meets 300V requirements specified by NEC
Applications:
Indoor within ducts, plenum and other spaces used for environmental air:
• Initiating Devices
• Signal Line Circuits
• Notification Devices
• Control Circuts
• Audio Circuits
Catalog
No.
60991S
No. of
Conductors
Cond.
Type &
Nom. DCR
Insulation
Type &
Thickness
Inches
1 Pair
16 AWG
Strd
4.1Ω/Mft
.008
60993S
60995S
1 Pair
1 Pair
14 AWG
Strd
2.6Ω/Mft
12 AWG
Strd
1.8Ω/Mft
.010
.010
Shielding
None
None
None
Jacket
Type &
Thickness
Inches
Nom. O.D
Inches
.015
.015
.015
.180
.210
.254
NEC
Type
Nom.
Capacitance
FPLP
FPLP
FPLP
33 pf/ft
34 pf/ft
40 pf/ft
Jacket
Colors
RD
RD
RD
4 www.westpenn-wpw.com | 800-245-4964 | Specifications subject to change | WEST PENN WIRE
Bulk Cable | Aquaseal® Direct Burial WEST PENN WIRE
Unshielded |
Catalog
No.
AQ224
AQ244
AQ225
AQ245
AQ226
AQ246
AQ227
FPL /CL3/PLTC Features:
• Mid-Capacitance Performance
• UL Listed and Direct Burial- UL1685
• Two-Ply waterblocking tapes
• Meets 300V requirements specified by NEC
No. of
Conductors
Cond.
Type &
Nom. DCR
1 Pair
4
1 Pair
4
1 Pair
4
18 AWG
Solid
6.5Ω/Mft
18 AWG
Solid
6.5Ω/Mft
16 AWG
Solid
4.1Ω/Mft
16 AWG
Solid
4.1Ω/Mft
14 AWG
Solid
2.6Ω/Mft
14 AWG
Solid
2.6Ω/Mft
Insulation
Type &
Thickness
Inches
PVC .015
Nylon .005
PVC .015
Nylon .005
PVC .015
Nylon .005
PVC .015
Nylon .005
PVC .015
Nylon .005
PVC .015
Nylon .005
1 Pair
12 AWG
Solid
1.8Ω/Mft
PVC .015
Nylon .005
Shielding
None
None
None
None
None
None
None
Jacket
Type &
Thickness
Inches
.035
.040
.040
.040
.040
.040
.040
Nom. O.D
Inches
.270
.327
.295
.355
.310
.395
.340
NEC
Type
CL3/FPL
PLTC
CL3/FPL
PLTC
CL3/FPL
PLTC
CL3/FPL
PLTC
CL3/FPL
PLTC
CL3/FPL
PLTC
CL3/FPL
PLTC
Applications:
Indoor / Outdoor Use: DIRECT BURIAL
• Signal Line Circuits
• Notification Devices
• Control Circuts
• Audio Circuits
Nom.
Capacitance
25 pf/ft
25 pf/ft
28 pf/ft
28 pf/ft
32 pf/ft
32 pf/ft
36 pf/ft
Jacket
Colors
BK
BK
BK
BK
BK
BK
BK
Bulk Cable | Aquaseal® In-Conduit
Unshielded | FPL /CL3/CM
Features:
• Mid-Capacitance Performance
• UL Listed CM/CL3 AND FPL
• Two-Ply waterblocking tapes
• Meets 300V requirements specified by NEC
WEST PENN WIRE
Applications:
Indoor / Outdoor Use: IN-CONDUIT
• Signal Line Circuits
• Notification Devices
• Control Circuts
• Audio Circuits
Catalog
No.
AQC224
No. of
Conductors
Cond.
Type &
Nom. DCR
Insulation
Type &
Thickness
Inches
1 Pair
18 AWG
7X26
6.2Ω/Mft
PVC
.010
AQC225
AQC226
1 Pair
1 Pair
16 AWG
19X29
4.2Ω/Mft
14 AWG
19X27
2.7Ω/Mft
PVC
.010
PVC
.010
Shielding
None
None
None
Jacket
Type &
Thickness
Inches
PVC
.025
PVC
.025
PVC
.025
Nom. O.D
Inches
.218
.242
.294
NEC
Type
CM/CL3
FPL
CM/CL3
FPL
CM/CL3
FPL
Nom.
Capacitance
29 pf/ft
32 pf/ft
34 pf/ft
Jacket
Colors
GY
GY
GY www.westpenn-wpw.com | 800-245-4964 | Specifications subject to change | WEST PENN WIRE
5
Bulk Cable | FIRE ALARM
Shielded | FPLR
WEST PENN WIRE
Features:
• Mid-Capacitance Performance
• Some Product Available in Multiple Jacket Colors
• Riser Rated UL Listed - UL1666
• Meets 300V requirements specified by NEC
Applications:
Indoor for:
• Initiating Devices
• Signal Line Circuits
• Notification Devices
• Control Circuts
• Audio Circuits
Catalog
No.
975
977
991
993
995
999
No. of
Conductors
Cond.
Type &
Nom. DCR
1 Pair
4
1 Pair
4
1 Pair
1 Pair
18 AWG
Solid
6.5Ω/Mft
18 AWG
Solid
6.5Ω/Mft
16 AWG
Solid
4.1Ω/Mft
16 AWG
Solid
4.1Ω/Mft
14 AWG
Solid
2.6Ω/Mft
12 AWG
Solid
1.8Ω/Mft
Insulation
Type &
Thickness
Inches
PP*
.008
Shielding
AL. Foil
100%
PP*
.008
PP*
.008
PP*
.008
PP*
.012
PP*
.012
AL. Foil
100%
AL. Foil
100%
AL. Foil
100%
AL. Foil
100%
AL. Foil
100%
Jacket
Type &
Thickness
Inches
PVC
.017
PVC
.017
Nom. O.D
Inches
.150
.180
PVC
.017
PVC
.017
PVC
.017
PVC
.017
.172
.200
.215
.248
NEC
Type
Nom.
Capacitance
FPLR
FPLR
FPLR
FPLR
FPLR
38 pf/ft*
69 pf/ft**
38 pf/ft*
69 pf/ft**
43 pf/ft*
78 pf/ft**
39 pf/ft*
70 pf/ft**
39 pf/ft*
70 pf/ft**
Jacket
Colors
RD, BL,WH,YE
RD
RD, BL, WH, YE
RD
RD
FPLR
44 pf/ft*
77 pf/ft**
RD
* Capacitance between conductors
** Capacitance between one conductor and
the other connected to the shield
Special Notes:
• Selected Plenum Versions see page
• Selected Indoor/Outdoor Versions see Aquaseal
• Select items are packaged in our Advantage Box.
• Rip cord under jacket
• PP* - Polypropylene
• Spools Size - Standard 1000ft Put-ups
• Tracer markings available upon request
6 www.westpenn-wpw.com | 800-245-4964 | Specifications subject to change | WEST PENN WIRE
Bulk Cable | FIRE ALARM Plenum WEST PENN WIRE
Shielded | FPLP Features:
• Mid-Capacitance Performance
• Some Product Available in Multiple Jacket Colors
• Plenum Rated - UL Listed NFPA262
• Meets 300V requirements specified by NEC
Applications:
Indoor within ducts, plenum and other spaces used for environmental air:
• Initiating Devices
• Signal Line Circuits
• Notification Devices
• Control Circuts
• Audio Circuits
Catalog
No.
60975B
60977B
60990B
603164B
60992B
No. of
Conductors
Cond.
Type &
Nom. DCR
1 Pair
4
1 Pair
4
1 Pair
18 AWG
Solid
6.5Ω/Mft
18 AWG
Solid
6.5Ω/Mft
16 AWG
Solid
4.1Ω/Mft
16 AWG
Solid
4.1Ω/Mft
14 AWG
Solid
2.6Ω/Mft
Insulation
Type &
Thickness
Inches
Polymer
Alloy
.008
Polymer
Alloy
.008
Polymer
Alloy
.008
Polymer
Alloy
.008
Polymer
Alloy
.008
Shielding
AL. Foil
100%
AL. Foil
100%
AL. Foil
100%
AL. Foil
100%
AL. Foil
100%
60994B 1 Pair
12 AWG
Solid
1.8Ω/Mft
Polymer
Alloy
.008
AL. Foil
100%
Special Notes:
• Plenum Installation precautions see Technical Reference Section
• Selected items are packaged in our Advantage Box
• Spools Size - Standard 1000ft Put-ups
• FR PVC* - Flame Retardant Flexible PVC
Jacket
Type &
Thickness
Inches
FR PVC*
.015
FR PVC*
.015
FR PVC*
.015
FR PVC*
.015
FR PVC*
.015
FR PVC*
.015
Nom. O.D
Inches
.148
.170
.168
.195
.202
.243
NEC
Type
FPLP
FPLP
FPLP
FPLP
FPLP
Nom.
Capacitance
66 pf/ft*
119 pf/ft**
66 pf/ft*
119 pf/ft**
77 pf/ft*
139 pf/ft**
77 pf/ft*
139 pf/ft**
84 pf/ft*
151 pf/ft**
Jacket
Colors
RD
RD
RD
RD
RD
FPLP
84 pf/ft*
151 pf/ft**
RD
* Capacitance between conductors
** Capacitance between one conductor and
the other connected to the shield www.westpenn-wpw.com | 800-245-4964 | Specifications subject to change | WEST PENN WIRE
7
Bulk Cable
Shielded | FPLR
| FIRE ALARM
Stranded Conductors
Features:
• Mid-Capacitance Performance
• Stranded Conductors for Flex Installations
• Riser Rated UL Listed - UL1666
• Meets 300V requirements specified by NEC
WEST PENN WIRE
Applications:
Indoor for:
• Initiating Devices
• Signal Line Circuits
• Notification Devices
• Control Circuts
• Audio Circuits
Catalog
No.
995S
999S
No. of
Conductors
Cond.
Type &
Nom. DCR
Insulation
Type &
Thickness
Inches
1 Pair
14 AWG
Stranded
2.6Ω/Mft
PP*
.012
1 Pair
12 AWG
Stranded
1.8Ω/Mft
PP*
.012
Shielding
AL. Foil
100%
AL. Foil
100%
Jacket
Type &
Thickness
Inches
PVC
.017
Nom. O.D
Inches
.232
PVC
.017
.264
NEC
Type
Nom.
Capacitance
FPLR
39 pf/ft*
70 pf/ft**
Jacket
Colors
RD
FPLR
44 pf/ft*
77 pf/ft**
RD
* Capacitance between conductors
** Capacitance between one conductor and
the other connected to the shield
Shielded | FPLP Features:
• Mid-Capacitance Performance
• Stranded Conductors for Flex Installations
• Plenum Rated - UL Listed NFPA262
• Meets 300V requirements specified by NEC
Applications:
Indoor within ducts, plenum and other spaces used for environmental air:
• Initiating Devices
• Signal Line Circuits
• Notification Devices
• Control Circuts
• Audio Circuits
Catalog
No.
60990BS
No. of
Conductors
Cond.
Type &
Nom. DCR
Insulation
Type &
Thickness
Inches
1 Pair
16 AWG
Stranded
4.1Ω/Mft
.008
60992BS
60994BS
1 Pair
1 Pair
14 AWG
Stranded
2.6Ω/Mft
12 AWG
Stranded
1.8Ω/Mft
.008
.008
Shielding
AL. Foil
100%
AL. Foil
100%
AL. Foil
100%
Jacket
Type &
Thickness
Inches
FR PVC*
.015
Nom. O.D
Inches
.174
FR PVC*
.015
FR PVC*
.015
.210
.249
NEC
Type
Nom.
Capacitance
FPLP
FPLP
77 pf/ft*
139 pf/ft**
84 pf/ft*
151 pf/ft**
Jacket
Colors
RD
RD
FPLP
84 pf/ft*
151 pf/ft**
RD
* Capacitance between conductors
** Capacitance between one conductor and
the other connected to the shield
Special Notes:
• Plenum Installation precautions see Technical Reference Section
• Selected items are packaged in our Advantage Box
• Spools Size - Standard 1000ft Put-ups
• FR PVC* - Flame Retardant Flexible PVC
8 www.westpenn-wpw.com | 800-245-4964 | Specifications subject to change | WEST PENN WIRE
Bulk Cable | Aquaseal® Direct Burial WEST PENN WIRE
Shielded | FPL /CL3/PLTC Features:
• Mid-Capacitance Performance
• UL Listed and Direct Burial- UL1685
• Two-Ply waterblocking tapes
• Meets 300V requirements specified by NEC
Catalog
No.
AQ293
AQ3244
AQ294
AQ3245
AQ295
No. of
Conductors
Cond.
Type &
Nom. DCR
1 Pair
4
1 Pair
4
1 Pair
18 AWG
Solid
6.5Ω/Mft
18 AWG
Solid
6.5Ω/Mft
16 AWG
Solid
4.1Ω/Mft
16 AWG
Solid
4.1Ω/Mft
14 AWG
Solid
2.6Ω/Mft
Insulation
Type &
Thickness
Inches
PVC .015
Nylon .005
PVC .015
Nylon .005
PVC .015
Nylon .005
PVC .015
Nylon .005
PVC .015
Nylon .005
AQ296 1 Pair
12 AWG
Solid
1.8Ω/Mft
PVC .015
Nylon .005
Shielding
AL. Foil
100%
AL. Foil
100%
AL. Foil
100%
AL. Foil
100%
AL. Foil
100%
AL. Foil
100%
Applications:
Indoor / Outdoor Use: DIRECT BURIAL
• Signal Line Circuits
• Notification Devices
• Control Circuts
• Audio Circuits
Jacket
Type &
Thickness
Inches
.040
Nom. O.D
Inches
.310
.040
.371
NEC
Type
CL3/FPL
PLTC
CL3/FPL
PLTC
Nom.
Capacitance
32 pf/ft*
58 pf/ft**
32 pf/ft*
58 pf/ft**
.040
.040
.040
.040
.328
.415
.350
.375
CL3/FPL
PLTC
CL3/FPL
PLTC
CL3/FPL
PLTC
37 pf/ft*
67 pf/ft**
37 pf/ft*
67 pf/ft**
46 pf/ft*
83 pf/ft**
Jacket
Colors
BK
BK
BK
BK
BK
CL3/FPL
PLTC
54 pf/ft*
97 pf/ft**
BK
* Capacitance between conductors
** Capacitance between one conductor and
the other connected to the shield
Bulk Cable | Aquaseal®
Shielded | FPL /CL3/CM
In-Conduit
Features:
• Mid-Capacitance Performance
• UL Listed CM/CL3 AND FPL
• Two-Ply waterblocking tapes
• Meets 300V requirements specified by NEC
WEST PENN WIRE
Applications:
Indoor / Outdoor Use: IN-CONDUIT
• Signal Line Circuits
• Notification Devices
• Control Circuts
• Audio Circuits
Catalog
No.
AQC293
No. of
Conductors
Cond.
Type &
Nom. DCR
Insulation
Type &
Thickness
Inches
1 Pair
18 AWG
7X26
6.2Ω/Mft
.010
AQC294
AQC295
1 Pair
1 Pair
16 AWG
19X29
4.2Ω/Mft
14 AWG
19X27
2.7Ω/Mft
.010
.010
Shielding
AL. Foil
100%
AL. Foil
100%
AL. Foil
100%
Jacket
Type &
Thickness
Inches
PVC
.025
PVC
.025
PVC
.025
Nom. O.D
Inches
.257
.281
.333
NEC
Type
CM/CL3
FPL
CM/CL3
FPL
Nom.
Capacitance
46 pf/ft*
83 pf/ft**
54 pf/ft*
97 pf/ft**
CM/CL3
FPL
59 pf/ft*
106 pf/ft**
Jacket
Colors
GY
GY
GY www.westpenn-wpw.com | 800-245-4964 | Specifications subject to change | WEST PENN WIRE
9
Bulk Cable | FIRE ALARM - Addressable
Unshielded | FPLR Features:
• Low-Capacitance Performance
• Digital Audio Impedance Performance
• Riser Rated UL Listed - UL1666
• Meets 300V requirements specified by NEC
WEST PENN WIRE
Applications:
Indoor for:
• Initiating Devices
• Signal Line Circuits
• Notification Devices
• Control Circuts
• Audio Circuits - Digital Audio Loops
Catalog
No.
D980
D990
No. of
Conductors
Cond.
Type &
Nom. DCR
1 Pair
1 Pair
18 AWG
Solid
6.5Ω/Mft
16 AWG
Solid
4.1Ω/Mft
Insulation
Type &
Thickness
Inches
Polyolefin
.015
Polyolefin
.015
Shielding
None
None
Jacket
Type &
Thickness
Inches
PVC
.030
Nom. O.D
Inches
.196
PVC
.030
.223
NEC
Type
FPLR
FPLR
Nom.
Capacitance
&
Impedance
15 pf/ft
105Ω
17 pf/ft
105Ω
Jacket
Colors
RD
RD
Bulk Cable
Shielded | FPLR
| FIRE ALARM - Addressable
Features:
• Lpw-Capacitance Performance
• Addressable - Data Link Systems
• Riser Rated UL Listed - UL1666
• Meets 300V requirements specified by NEC
WEST PENN WIRE
Applications:
Indoor for:
• Initiating Devices
• Signal Line Circuits
• Notification Devices
• Control Circuts
• Audio Circuits
Catalog
No.
D975
D991
D995
No. of
Conductors
Cond.
Type &
Nom. DCR
1 Pair
1 Pair
1 Pair
18 AWG
Solid
6.5Ω/Mft
16 AWG
Solid
4.1Ω/Mft
14 AWG
Solid
2.6Ω/Mft
Insulation
Type &
Thickness
Inches
Polyolefin
.015
Polyolefin
.015
Polyolefin
.020
Shielding
AL. Foil
100%
AL. Foil
100%
AL. Foil
100%
Jacket
Type &
Thickness
Inches
PVC
.035
Nom. O.D
Inches
.223
PVC
.035
PVC
.035
.245
.281
NEC
Type
Nom.
Capacitance
FPLR
FPLR
25 pf/ft*
45 pf/ft**
30 pf/ft*
54 pf/ft**
Jacket
Colors
RD
RD
FPLR
30 pf/ft*
54 pf/ft**
RD
* Capacitance between conductors
** Capacitance between one conductor and
the other connected to the shield
10 www.westpenn-wpw.com | 800-245-4964 | Specifications subject to change | WEST PENN WIRE
Bulk Cable | FIRE ALARM Plenum
Unshielded | FPLP Features:
• Low-Capacitance Performance
• Digital Audio Impedance Performance
• Plenum Rated - UL Listed NFPA262
• Meets 300V requirements specified by NEC
WEST PENN WIRE
Applications:
Indoor within ducts, plenum and other spaces used for environmental air:
• Initiating Devices
• Signal Line Circuits
• Notification Devices
• Control Circuts
• Audio Circuits
Catalog
No.
D60980
D60991
No. of
Conductors
Cond.
Type &
Nom. DCR
1 Pair
1 Pair
18 AWG
Solid
6.5Ω/Mft
16 AWG
Solid
4.1Ω/Mft
Insulation
Type &
Thickness
Inches
FEP
.012
Shielding
None
FEP
.012
None
Jacket
Type &
Thickness
Inches
.015
Nom. O.D
Inches
.144
.015
.164
NEC
Type
Nom.
Capacitance
FPLP
FPLP
15 pf/ft
16 pf/ft
Jacket
Colors
RD
RD
Bulk Cable | FIRE ALARM Plenum
Shielded | FPLP Features:
• Mid-Capacitance Performance
• Addressable - Data Link Systems
• Plenum Rated - UL Listed NFPA262
• Meets 300V requirements specified by NEC
WEST PENN WIRE
Applications:
Indoor within ducts, plenum and other spaces used for environmental air:
• Initiating Devices
• Signal Line Circuits
• Notification Devices
• Control Circuts
• Audio Circuits
Catalog
No.
60975B
60990B
No. of
Conductors
Cond.
Type &
Nom. DCR
1 Pair
1 Pair
18 AWG
Solid
6.5Ω/Mft
16 AWG
Solid
4.1Ω/Mft
Insulation
Type &
Thickness
Inches
FEP
.012
FEP
.012
Shielding
AL. Foil
100%
AL. Foil
100%
Jacket
Type &
Thickness
Inches
FR PVC*
.015
Nom. O.D
Inches
.165
FR PVC*
.015
.188
NEC
Type
Nom.
Capacitance
FPLP
25 pf/ft*
45 pf/ft**
Jacket
Colors
RD
FPLP
30 pf/ft*
54 pf/ft**
RD
* Capacitance between conductors
** Capacitance between one conductor and
the other connected to the shield
Special Notes:
• Plenum Installation precautions see Technical Reference Section
• Selected items are packaged in our Advantage Box
• Spools Size - Standard 1000ft Put-ups
• Tracer markings available upon request www.westpenn-wpw.com | 800-245-4964 | Specifications subject to change | WEST PENN WIRE
11
Bulk Cable | FIRE ALARM - Local Law 5 (LL5)
Unshielded | FPLP LL5 Features:
• Mid-Capacitance Performance
• 150˚ Performance
• New York City- Fire Alarm Cable LL5
• Plenum Rated - UL Listed NFPA262
• Meets 300V requirements specified by NEC
WEST PENN WIRE
Applications:
Indoor for:
• Initiating Devices
• Signal Line Circuits
• Notification Devices
• Control Circuts
Catalog
No.
LL5182
LL5184
LL5162
LL5164
LL5142
LL5144
No. of
Conductors
Cond.
Type &
Nom. DCR
Insulation
Type &
Thickness
Inches
1 Pair
4
1 Pair
4
1 Pair
4
18 AWG
Solid
6.5Ω/Mft
18 AWG
Solid
6.5Ω/Mft
16 AWG
Solid
4.1Ω/Mft
16 AWG
Solid
4.1Ω/Mft
14 AWG
Solid
2.6Ω/Mft
14 AWG
Solid
2.6Ω/Mft
.016
.016
.016
.016
.016
.016
LL5122 1 Pair
12 AWG
Solid
1.8Ω/Mft
.016
Special Notes:
• Insulation and Jacketing Compounds
(Fluoropolymers) are rated for 150˚ Performance.
Shielding
None
None
None
None
None
None
None
Jacket
Type &
Thickness
Inches
.026
Nom. O.D
Inches
.205
.026
.026
.026
.026
.026
.026
.238
.225
.265
.248
.302
.278
NEC
Type
Nom.
Capacitance
FPLP
FPLP
FPLP
FPLP
FPLP
FPLP
FPLP
29 pf/ft
29 pf/ft
32 pf/ft
32 pf/ft
35 pf/ft
35 pf/ft
45 pf/ft
Jacket
Colors
RD
RD
RD
RD
RD
RD
RD
12 www.westpenn-wpw.com | 800-245-4964 | Specifications subject to change | WEST PENN WIRE
Bulk Cable | FIRE ALARM - Local Law 5 (LL5) WEST PENN WIRE
Shielded | FPLP Features:
• Mid-Capacitance Performance
• Some Product Available in Multiple Jacket Colors
• Plenum Rated - UL Listed NFPA262
• Meets 300V requirements specified by NEC
Applications:
Indoor within ducts, plenum and other spaces used for environmental air:
• Initiating Devices
• Signal Line Circuits
• Notification Devices
• Control Circuts
• Audio Circuits
Catalog No.
No. of
Conductors
Cond.
Type &
Nom. DCR
Insulation
Type &
Thickness
Inches
LL5182SH
LL5184SH
LL5162SH
LL5164SH
LL5142SH
LL5122SH
1 Pair
4
1 Pair
4
1 Pair
1 Pair
18 AWG
Solid
6.5Ω/Mft
18 AWG
Solid
6.5Ω/Mft
16 AWG
Solid
4.1Ω/Mft
16 AWG
Solid
4.1Ω/Mft
14 AWG
Solid
2.6Ω/Mft
12 AWG
Solid
1.8Ω/Mft
.016
.016
.016
.016
.016
.016
Special Notes:
• Insulation and Jacketing Compounds
(Fluoropolymers) are rated for 150˚ Performance.
Shielding
AL. Foil
100%
AL. Foil
100%
AL. Foil
100%
AL. Foil
100%
AL. Foil
100%
AL. Foil
100%
Jacket
Type &
Thickness
Inches
.026
.026
.026
.026
.026
.026
Nom. O.D
Inches
.210
.245
.230
.272
.258
.285
NEC
Type
FPLP
FPLP
FPLP
FPLP
FPLP
Nom.
Capacitance
54 pf/ft*
97 pf/ft**
54 pf/ft*
97 pf/ft**
61 pf/ft*
110 pf/ft**
61 pf/ft*
110 pf/ft**
84 pf/ft*
151 pf/ft**
Jacket
Colors
RD
RD
RD
RD
RD
FPLP
84 pf/ft*
151 pf/ft**
RD
* Capacitance between conductors
** Capacitance between one conductor and
the other connected to the shield www.westpenn-wpw.com | 800-245-4964 | Specifications subject to change | WEST PENN WIRE
13
Bulk Cable | FIRE ALARM - Power Limited
Parallel
Unshielded | FPL Features:
•2 Conductor Parallel
• Hook-Up Constructed
WEST PENN WIRE
Applications:
Indoor for:
• Smoke Detectors
• Signal
• Detection/Monitor
Catalog
No.
970
971
972
No. of
Conductors
Cond.
Type &
Nom. DCR
2
2
2
18 AWG
Solid
6.5Ω/Mft
16 AWG
Solid
4.1Ω/Mft
14 AWG
Solid
2.6Ω/Mft
Insulation
Type &
Thickness
Inches
PVC
.032
PVC
.032
PVC
.032
Shielding
None
None
None
Jacket
Type &
Thickness
Inches
None
None
None
Nom. O.D
Inches
.104x.204
.115x.225
.128x.228
Bulk Cable | FIRE ALARM -
Non-Powered Limited
Shielded | FPLR Features:
• Non-Power Limited
NEC
Type
Nom.
Capacitance
FPL
FPL
FPL
--
--
--
Jacket
Colors
RD
RD
RD
WEST PENN WIRE
Applications:
Indoor for:
• Initiating Devices
• Signal Line Circuits
• Notification Devices
• Control Circuts
• Audio Circuits
Catalog
No.
1975
1991
No. of
Conductors
Cond.
Type &
Nom. DCR
1 Pair
1 Pair
18 AWG
Solid
6.5Ω/Mft
16 AWG
Solid
4.1Ω/Mft
Insulation
Type &
Thickness
Inches
PVC .016
Nylon .005
PVC .016
Nylon .005
Shielding
AL. Foil
100%
AL. Foil
100%
Jacket
Type &
Thickness
Inches
PVC
.037
PVC
.037
Nom. O.D
Inches
.244
.264
NEC
Type
NPLF
NPLF
Nom.
Capacitance
52 pf/ft*
94 pf/ft**
57 pf/ft*
103 pf/ft**
Jacket
Colors
RD
RD
1995 1 Pair
14 AWG
Solid
2.6Ω/Mft
PVC .016
Nylon .005
AL. Foil
100%
PVC
.037
.284
NPLF
64 pf/ft*
115 pf/ft**
RD
Power Limited vs. Non-Power Limited
* Capacitance between conductors
** Capacitance between one conductor and
the other connected to the shield
Power-Limited Fire Alarm (PLFA) Circuits. A power-limited fire alarm circuit is one that is inherently unable to exceed maximum voltages, or is equipped with a power-limiting source (transformer or battery) and a circuit breaker. Generally, these operate in the 24-volt direct current range, although they may employ higher voltages. 300V Rating - FPL,
FPLR, or FPLP
Nonpower-LimitedFireAlarm(NPLFA)Circuits. Nonpower-limitedfire alarm circuits cannot operate at more than 600 volts, and there is no other power or current limitation for these systems. Usually these are used in 120- volt alternating current (AC) systems which have been rendered generally obsolete by the advent of low-voltage, direct current
(DC) systems. 600V Rating - NPLF, NPLFP
14 www.westpenn-wpw.com | 800-245-4964 | Specifications subject to change | WEST PENN WIRE
Bulk Cable | Cable Finder
18 AWG UNSHIELDED
AWG # Cond.
SOL/STRD
RISER RATED - FPLR
18 2
18 4
PLENUM RATED - FPLP
18
18
2
4
SOL
SOL
SOL
SOL
DCR
Ohms
6.5
6.5
6.5
6.5
Nom.Cap
pf/ft.
19
19
31
31
Part No.
980
982
60980B
60982B
WEST PENN WIRE
18 AWG SHIELDED
AWG # Cond.
RISER RATED - FPLR
18 2
18 4
PLENUM RATED - FPLP
18
18
2
4
SOL/STRD
SOL
SOL
SOL
SOL
DCR
Ohms
6.5
6.5
6.5
6.5
Nom.Cap
pf/ft.
39
39
66
66
Part No.
975
977
60975B
60977B
16 AWG UNSHIELDED
AWG # Cond.
SOL/STRD
RISER RATED - FPLR
16 2
16
16
2
4
PLENUM RATED - FPLP
16 2
16
16
2
4
SOL
STRD
SOL
SOL
STRD
SOL
DCR
Ohms
4.1
4.1
4.1
4.1
4.1
4.1
Nom.Cap
pf/ft.
20
20
20
34
34
34
Part No.
990
990S
992
60991B
60991BS
60164B
16 AWG SHIELDED
AWG # Cond.
RISER RATED - FPLR
16 2
16 4
PLENUM RATED - FPLP
16
16
16
2
2
4
SOL/STRD
SOL
SOL
SOL
STRD
SOL
DCR
Ohms
4.1
4.1
4.1
4.1
4.1
Nom.Cap
pf/ft.
38
38
77
77
77
Part No.
975
977
60975B
90990BS
60977B
14 AWG UNSHIELDED
AWG # Cond.
RISER RATED - FPLR
14 2
14
14
2
4
PLENUM RATED - FPLP
14 2
14
14
2
4
SOL/STRD
SOL
STRD
SOL
SOL
STRD
SOL
DCR
Ohms
4.1
4.1
4.1
4.1
4.1
4.1
Nom.Cap
pf/ft.
22
22
22
33
33
33
Part No.
994
994S
700
60993B
60993BS
60700B
14 AWG SHIELDED
AWG # Cond.
RISER RATED - FPLR
14 2
14 2
PLENUM RATED - FPLP
14
14
2
2
SOL/STRD
SOL
STRD
SOL
STRD
DCR
Ohms
4.1
4.1
4.1
4.1
Nom.Cap
pf/ft.
43
43
84
84
Part No.
995
995S
60992B
60992BS
12 AWG UNSHIELDED
AWG # Cond.
RISER RATED - FPLR
12 2
12 2
PLENUM RATED - FPLP
12
12
2
2
SOL/STRD
SOL
STRD
SOL
STRD
DCR
Ohms
4.1
4.1
4.1
4.1
Nom.Cap
pf/ft.
22
22
40
40
Part No.
998
998S
60995B
60995BS
12 AWG SHIELDED
AWG # Cond.
SOL/STRD
RISER RATED - FPLR
12 2
12 2
PLENUM RATED - FPLP
12
12
2
2
SOL
STRD
SOL
STRD
DCR
Ohms
4.1
4.1
4.1
4.1
Nom.Cap
pf/ft.
44
44
96
96
Part No.
999
999S
60994B
60994BS www.westpenn-wpw.com | 800-245-4964 | Specifications subject to change | WEST PENN WIRE
15
Bulk Cable | FIRE ALARM - Local Law 5 (LL5) WEST PENN WIRE
MID CAPACITANCE UNSHIELDED CABLES
AWG # Cond.
SOL/STRD
DCR
Ohms
RISER RATED - FPLR
18 2
16 2
PLENUM RATED - FPLP
18
16
Impedance:
D980: 110Ω
D990: 103Ω
2
2
SOL
SOL
SOL
SOL
6.5
4.1
6.5
4.1
Nom.Cap
pf/ft.
15
17
15
17
Part No.
D980
D990
D60980
D60991
Fire Alarm Cables by
WEST PENN WIRE
INDOOR/OUTDOOR DIRECT BURIAL FIRE ALARM CABLES
MID CAPACITANCE SHIELDED CABLES
AWG # Cond.
SOL/STRD
DCR
Ohms
RISER RATED - FPLR
18 2
16
14
2
2
PLENUM RATED - FPLP
18 2
16 2
SOL
SOL
SOL
SOL
SOL
6.5
4.1
2.6
6.5
4.1
Nom.Cap
pf/ft.
24
29
29
24
29
Part No.
D975
D991
D995
D609975
D60990
UNSHIELDED - DIRECT BURIAL FPL RATED
AWG # Cond.
SOL/STRD
DCR
Ohms
2 CONDUCTOR FPL RATED
18 2
16
14
2
2
12 2
4 CONDUCTOR FPL RATED
18
16
14
4
4
4
STRD
STRD
STRD
STRD
STRD
STRD
STRD
6.5
4.1
2.7
6.5
4.1
2.7
1.7
Nom.Cap
pf/ft.
24
26
31
35
24
26
31
Part No.
AQ224
AQ225
AQ226
AQ227
AQ244
AQ245
AQ246
SHIELDED - DIRECT BURIAL FPL RATED
AWG # Cond.
SOL/STRD
DCR
Ohms
2 CONDUCTOR FPL RATED
18 2
16
14
2
2
12 2
4 CONDUCTOR FPL RATED
18
16
4
4
STRD
STRD
STRD
STRD
STRD
STRD
6.5
4.1
6.5
4.1
2.7
1.7
Nom.Cap
pf/ft.
31
36
45
52
31
36
Part No.
AQ293
AQ294
AQ295
AQ296
AQ3244
AQ3245
Fire Alarm Cables by
WEST PENN WIRE
INDOOR/OUTDOOR IN-CONDUIT FIRE ALARM CABLES
UNSHIELDED - IN-CONDUIT FPL RATED
AWG # Cond.
SOL/STRD
DCR
Ohms
2 CONDUCTOR FPL RATED
18 2
16
14
2
2
STRD
STRD
STRD
6.5
4.1
2.7
Nom.Cap
pf/ft.
29
31
33
Part No.
AQC224
AQC225
ACQ226
UNSHIELDED - IN-CONDUIT FPL RATED - Digital Audio Loops
AWG # Cond.
SOL/STRD
DCR Nom.Cap
Pending UL
2 CONDUCTOR FPL RATED
18 2 STRD 6.5
15
Impedance:
AQC182: 110Ω
Part No.
AQC182
SHIELDED - IN-CONDUIT FPL RATED
AWG # Cond.
SOL/STRD
DCR
Ohms
2 CONDUCTOR FPL RATED
18 2
16
14
2
2
STRD
STRD
STRD
6.5
4.1
2.7
Nom.Cap
pf/ft.
45
53
57
A. Color Code
Cond.
Conductor Colors
1
2
Red
Black
3
4
Brown
Blue
Jacket Colors: Standard Color: RD
Part No.
AQC293
AQC294
ACQ295
16 www.westpenn-wpw.com | 800-245-4964 | Specifications subject to change | WEST PENN WIRE
SYSTEM LAYOUTS:
The initiating circuits that connect detectors to a control panel should be supervised so that a fault (trouble) condition that could interfere with the proper operation of the circuit will be detected and annunciated.
Detectors are generally categorized as either 2-wire or 4-wire detectors.Two-wire detectors derive theirpower directly from the same fire alarm control panel alarm initiating device circuit over which they reportan alarm.Because of their dependency on the initiating circuit, 2-wire detectors must be tested and list-ed for compatibility with the control panel to be used, to ensure proper operation.
Four-wire detectors are powered from a separate pair of wires, and like the 2-wire detector, apply anelectrical short across the associated alarm initiating device to transmit an alarm.Because they do notderive their power from the alarm control panel circuit, compatibility is predicated upon the operatingparameters of the power supply to which the detectors are connected and not the initiating circuit.Supervision of the power to 4-wire detectors is mandated through the use of an end of line power super-vision relay (EOLR).When power is on, the relay contacts at the end of line relay are closed and con-nected in series with the end of line resistors beyond the last initiating device.Loss of power at anypoint in the power supply circuit will cause the relay to de-energize and a trouble condition to occur onthe initiating circuit.
CLASS B CIRCUITS : Class B circuits differentiate between short circuits across the loop ( alarm) and opens on the loop
(trouble).Supervision of this circuit is accomplished by passing a low current through the installationwiring and an
EOLR.Increases or decreases in this supervisory current are monitored by the fire alarmcontrol panel and will cause alarm or trouble conditions, respectively, to be indicated.A single onpen ina Class B circuit disables all devices electrically beyond open.
CLASS A CIRCUITS: Class A circuits also differentiate between short circuits across the loop and opens on the loop.Supervision is accomplished by monitoring the level of current passing through the installation wiringand the EOLR, which in a Class A circuit is an integral part of the fire alarm control panel.Class Awiring must return to and be terminated in the control panel.This technique requires a minimum of fourwires be terminated in the control panel, and further requires that the fire alarm control panel isdesigned to monitor Class A circuits.The additional circuitry neccessary for Class A supervisionenables the control panel to “condition”the initiating circuit to monitor the initiating circuit from both endswhen in a trouble mode due to an open fault on the loop.This “conditioning”ensures that all devices arecapable of responding and reporting an alarm despite a single open or non-simultaneous single groundfault on a circuit conductor.
WEST PENN WIRE CABLE WITH CONFIDENCE
FIRE ALARM SYSTEM MANUFACTURERS
Edwards System Technology ( EST) www.est.net
Faraday Fire
Fenwal Fire www.faradayllc.com
www.fenwalfire.com
Fike Fire Alarm
Fire Control Instruments
Fire-Lite Alarms
Gamewell
Harrington Signal www.fike.com
www.firecontrolinstruments.com
www.firelite.com
www.gamewell.com
www.harringtonfire.com
Hochiki
Notifier
Secutron
Sentrol
Siemens Cerberus
Silent Knight
Simplex Grinnell
System Sensor www.hochiki.com
www.notifier.com
www.secutron.com
www.sentrol.com
www.sbt.siemens.com www.silentknight.com
www.simplexgrinnell.com
www.systemsensor.com
CABLE WITH CONFIDENCE WEST PENN WIRE