1.0 General and Safety
• Do not install, operate or maintain this flow meter without reading, understanding and followingthe factory-supplied
instructions. Otherwise, injury or damage may result.
• Read these instructions carefully before beginning installation and save them for future reference.
• Observe all warnings and instructions marked on the product.
• Consider handling and lifting instructions to avoid damage.
• If the product does not operate normally, refer to the service instructions or to a qualified ARAD service engineer.
• There are no operator-serviceable parts inside this product.
2.0 Product Liability and Warranty
Arad’s standard products (the “Products”) are sold to Customer and are purchased by Customer under the terms of
warranty set forth herein below:
1. Arad warrants that the Products shall, under conditions of normal use and when properly installed, administered,
applied and maintained, be free from defects in material and workmanship (the “Warranty”), for a period of 12 months
following delivery thereof to Customer (the “Warranty Period”).
2. Arad’s sole obligation and liability under the Warranty shall be limited to the replacement, the repair or the refund of
the original purchase price, at Arad’s sole discretion, of any defective Products which are proven not to conform to the
Products’ specification and which are returned to the factory or service center designated by Arad during the Warranty
Period by the Customer after completing a failure report. All provided that written notice of such defect is given by the
Customer to Arad within 21 days after discovery thereof. Freight cost to such factory or service center will be paid by
the Customer and freight cost from such factory or service center to Customer will be paid by Arad.
3. Arad will not be responsible for and will have no obligation under the Warranty to any non-conformity of the Products,
caused, in whole or in part, as a result of misuse, abuse, tampering with or modification of any of the Products and/
or by accidents, fault or negligence, improper administration, application and/or use, installation, service, repair and/or
maintenance of the relevant Products, by act of vandalism or by any causes whatsoever (including but not limited to
environmental conditions) that are external thereto.
4. The foregoing warranty is a limited warranty and is exclusive and in lieu of all other warranties, express or implied,
including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose and shall
constitute the Customer’s sole and exclusive remedy with respect thereto. Replacement or repair in the manner
provided above will constitute fulfillment of all of Arad’s obligations with respect to the quality and performance
of the products. No dealer, distributor, agent or employee of either Arad or customer is authorized to modify these
warranties. Such modification shall be null and void and shall not bind Arad for any and all purposes.
5. Except and to the extent provided under the warranty, in no event shall Arad be liable, whether in contract, tort
or otherwise, for any damages, whether direct or indirect, consequential, incidental, special or punitive, resulting
from any defect in the products, including, without limitation, loss of profits, business, income, anticipated savings,
goodwill or other commercial loss, even if Arad had been advised of the possibility of such damages, except to the
extent that such liability may not lawfully be excluded.
Customer shall be solely responsible for the selection, use, efficiency and suitability of the Products.
3.0 Items Included With Order:
• One OCTAVE ultrasonic flow meter, size as indicated on the packaging box, pieced together into a complete compact
system (flow tube plus electronics).
• One OUTPUT module, either digital or analog (based on the customer’s order).
2
4.0 Supplied Documentation:
• Condensed installation and user manual.
• Report of factory meter settings.
• Certificate of calibration data.
5.0 Unpacking and Inspection
• This product has been thoroughly inspected and tested before shipment and is ready for operation.
• After carefully unpacking the meter, inspect for shipping damage before attempting to install. If any indication of
mechanical damage is found, immediately contact the responsible transportation service and your local ARAD LTD.
representative.
6.0 System Description and Measurement Method
• The OCTAVE’s measurement method is based on an ultrasonic, transit-time, dual-beam sensors which determines
the length of time it takes an ultrasonic sound wave to travel the distance between the two sensors located on the
meter’s body. The sensors function as both the sender and the receiver, each one alternating these functions so that
the ultrasonic wave travels both with and against the direction of the flow. Since the ultrasonic wave travels slower
against the flow than with the flow, the time difference of two waves traveling with and against the flow leads to
determining the velocity of the water.
• The OCTAVE ultrasonic flow meter is a battery-powered precision flow meter designed for linear, bidirectional flow
measurement of water.
• Flow measurement values can be transferred through the standard comminucation - digital or analog output.
• The OCTAVE can be set up for a wide range of applications.
7.0 Mechanical Data
Maximum Working Pressure
16 bar
Liquid Temperature
0.1 up to 50 º C
Precision Class
ISO 4064 rev.2005, Accuracy class 2
Configuration
Compact - The display is built in to the unit
Power Source
2 D size Li-battery: 10 years life time
Environmental Protection
IP 68, Ambient operation temp. -25°C up to +55°C
Display Units
Multi line 9 digit LCD display (Flow rate and volume units are programmable)
Volume Display Options
1. Net (Forward less reverse)
2. Forward only
3. Forward & reverse alternating
Outputs (optional)
4-20mA (powered loop)
Dual digital pulses process (open collector)
Dry Contact
Encoder output
Coupling Threads (only 11/2” and 2”)
BSP (See also instructions for installation of Octave with polymer body)
Connections
Flanges according to ISO, BS 10 and ANSI 150
Severity levels
Mechanical class M1
Electromagnetic environment class E1
Pressure Loss
ΔP 16
3
Dimensions
Model
Octave
Nominal size
(mm)
40 Threaded 50 Threaded
50
65
80
100
150
200
250
(inch)
1½ Threaded 2 Threaded
2
2.5
3
4
6
8
10
300
12
L – Length without couplings (mm)
300
300
200
200
225
250
300
350
449
499
W – Width (mm)
113
113
165
185
200
220
285
340
406
489
H – Height (mm)
155
155
194
210
210
223
282
332
383
456
h – Height (mm)
35
35
40
90
90
103
140
165
203
245
8
9
11.5
13
15
32
45
68
96
Weight (kg) - cast iron body
1.4
Weight (kg) - polymer body
1.45
H
h
L
B
8.0 Mechanical Installation
8.1 Handling the Flow Meter
Important handling information:
• Do not lift the Octave by the electronic housing.
• Do not carry the Octave by its lid.
• Do not place the Octave on the electronic housing.
• When handling the Octave, avoid hard blows, jolts or impacts.
8.2 Installation: Location and Position
Conditional installation
n
ctio
Dire
Flow
n
Flo
w
Di
re
cti
on
ctio
Dire
Flow
4
Wrong installation
Flow Direction
Recommended installation
Recommended: If this is not the highest point in the
system or a hydraulic jump has been installed to
keep the flow meter full.
Not recommended: If this is the highest point in a
system or if pipeline and/or flow meter is subject to
being emptied between uses avoid this installation.
The Following Examples are Arad’s Recommendations
For Achieving Top Performance
• When installing the Octave downstream of any hydraulic component (valve,
pump) the recommended installation requirements are no less than the
drawings recommendations.
For upstream & downstream straight pipes please use as much as installation site
will allow ( the longer the better)
• When installing Pressure Breaker after the meter - the pipe length should be at least 2 pipe
diameter (the longer the better).
2 DN
2 DN
2 DN
2 DN
tion
Flow
c
Dire
tion
c
Dire
Flow
Minimum of two (2) pipe
diameters before and after
2 pipe diameters before and
after elbows (90°)
2 DN
2 DN
N
10 D
tion
c
Dire
Flow
tion
c
Dire
Flow
Minimum of ten (10) pipe
diameters after pumps
Minimum of two (2) pipe
diameters before T connections
tion
c
Dire
Minimum of two (2) pipe
diameters after strainers
Flow Direction
Flow
2 DN
2 DN
2 DN
2 pipe diameters before and after elbows
(90°) in vertical installations
5
9.0 Polymeric Octave Installation – General Instructions
Please follow the general instructions for water meters (Check Valve, upstream & down stream and system flushing on
new installations).
Existing and new installations:
1. It is recommended that the meter will NOT be installed in the middle of the system,
so the meter will not suffer from the load of all the installed fixtures.
2. It is recommended that at least one side of meter will be connected to a PVC (or plastic) pipe. 3. Please make sure that the end connections are parallel and inline to each other.
4. When using standard tail piece, please use rubber gaskets only (not fiberglass)! After adding the gaskets the gap
between the end connection and the meter should not exceed 1mm.
Please unscrew the end connection in order to keep the recommended distance.
• Please do not use force in order to close the gap.
• Please don’t do any welding while the meter is connected to the pipe.
Rubber
gasket
1 mm max
6
5. If it is not possible to use plastic connections on one side of the
meter, please consider the use of our flexible couplings. These
couplings were especially developed for the polymeric Octave meters.
You will need to use this coupling only on one side of the meter - please
install the coupling on the outlet, if possible - as described in the below pictures.
5mm MAX
3mm MAX
6. Please start to tighten the end connections by hand. Final tightening will be with no more than 100Nm torque.
7. Please don’t do any welding while the meter is connected to the pipe.
8. In case it is not possible to use plastic end connections (at least on one side), please support the meter as shown in
the drawing below.
Support
Plastic end
connection
7
10.0 Notes
• For proper flow measurements, the OCTAVE’s measuring tube should be completely full at all times. Non-wetted
sensors show loss of signal. Though this will not cause damage to the meter, it will, however, not measure flow and
display zero.
• Flow direction: The OCTAVE is a bidirectional flow meter. Note the indicating arrow on the OCTAVE’s display for forward
and backward flows.
• In case of direct sunlight exposure, it is recommended to keep the lid closed, though no direct damage will occur with
the lid open.
• Do not expose the OCTAVE to excessive vibration. To avoid vibration, support the pipeline on both side of the meter
• Ambient working temperature: -25 to +55°C.
• Water working temperature: 0.1 to +50°C.
• To avoid measuring errors due to air in the flow tube, observe the following precautions:
• Since air collects at the highest point of the system, installation of the flowmeter should be at the lowest point.
• Always install control valves downstream of the meter in order to avoid cavitation.
• ever install the meter on a pump suction side in order to avoid cavitation.
11.0 Counter Flanges
• Refer to the standard dimensional drawings for flange spacing, accommodating for the thickness of gaskets.
• Install meter in line with the pipe axis. The flange faces must be parallel to each other.
• Permissible length deviation: Lmax - Lmin 0.5mm (0.02”).
12.0 Start-up
DDCheck that the meter has been installed correctly.
DDCheck that the flow rate and volume units are correctly preprogrammed on the display.
DDCheck that the output module is correctly attached.
13.0 Digital Display
m3
m3/h
Volume units
Flow rate units
Battery level
Flow direction
Alarm / No Water / Error
Output Mode
8
14.0 Electrical Outputs
The OCTAVE has several outputs options.
1. Dual pulse output for volumes.
2. Dry Contact output for volume.
3. Analog output (4-20mA) for flow.
14.1.1 Pulse Output Module Specification
Pulse types: 1. Open collector that allows current loading of 200mA, and up to 50volt.
2. Dry contact.
Outputs Diagram
Long
Cable
Octave Pulse
100ohm
EMI / RFI /
OverVoltage
PROTECTION
100ohm
RED
GREEN
BLACK
SHIELD
1
Pulse#1
1
Pulse#2
1
GND
Read-out
instrument
1
GROUND
Ground Cable
1
Short
Cable
Cables
Warning - Signal connection polarity is mandatory!
Wire
Long cable
Short cable
Red
Green
Black
Open
Ring Terminal
Function
Pulse Out#1
Pulse Out#2
GND
Ground / Shield
Ground
Output Characteristics
Outputs Type
Cable Length - supplied
Maximum Cable Length*
Maximum Applied Voltage
Open Drain
1.5/5 [meter]
500 [meter]
30 [Vdc]
* The maximum Cable length depends on:
Cable type, controler and electrical noise level
Cable Teldoor PN 8005003101 or similar
9
14.1.2 Dry Contact Module Specification
Outputs Diagram
Long
Cable
Out#1
Octave
Dry Contact
v1.0
Read-out
instrument
Out#2
24Vdc
GROUND
Short
Cable
Cables
Long cable
Short cable*
Wire
Red + Orange
Black + Brown
Red
Black
Yellow
Function
Out#1
Out#2
24V +
24V GROUND
* Signal connection polarity is mandatory!
Output Characteristics
Outputs Type
Cable Length - supplied
Maximum Cable Length*
Supply Voltage
Dry Contact
1.5/5 [meter]
500 [meter]
24 [Vdc]
* cable Teldoor PN 8005003101 or similar
10
1 4 . 1 . 3 4-20mA Module (Analog)
• The current output is a passive 4-20mA.
• 4mA is always “0” (zero) flow and the 20mA is factory programmable according to
the customer requirements.. (If the customer did not specify, the 20mA will be the
maximum flow rate).
Outputs Diagram
Long
Cable
(+)
(-)
Read-out
+
instrument
Octave
4/20mA
module
Shield
GROUND
GROUND
Short
Cable
Cables
Signal connection polarity is mandatory!
Wire
Long cable
Short cable
Red
Black
Open
Ring Terminal
Function
current loop +
current loop GROUND / SHIELD
GROUND
Output Characteristics
Outputs Type
Supplied Cable Length
Maximum Cable Length *
Loop supply voltage
Output Impedance
4-20mA
current output
1.5/5 [meter]
500 [meter]
12 - 24 [Vdc]
25 [M] typ
* cable Teldoor PN 8005003101 or similar
11
15.0 Module Replacement / Mounting Manual
1. Properly dry the area of the connector.
2.
3.
4.
5.
6.
Remove seal cover from the screw using tool with sharp edge.
Remove the screws using Allen key 3mm.
Remove the module/cover.
Properly dry again the area of the connector.
Make sure the module o-ring is in position.
If not, Insert new o-ring into the module. The o-ring must be lubricated (silicone grease).
7. Attach module to the connector.
8. Tight both screws by hand only, using Allen key 3 mm to achieve symmetric o-ring pressure,
then apply the torque 2 N*m with torque wrench.
9. Insert seal cover onto the screw.
12
16.0 GND Mounting Manual
1.
Insert M5 screw to ring terminal lug
2. Insert flat washer on top of ring terminal lug
3. Insert serrated washer on flat washer
4. Attach to the fork terminal lug and tight
5. Insert flat washer and serrated washer on the bolt. Use the correct washers according to bolt size
(M16 or M20 respectively) Insert the bolt to the hole on the pipe’s flange.
(Do not install on meter’s flange)
13
6. Slide the fork terminal lug between the flat washer and serrated washer
7. Add serrated washer on the other side of the bolt (On meter’s flange side)
8. Add flat washer on the serrated washer
9. Add nut and tight. Make sure fork terminal lug is in position.
14
16.1 Special Parts
Set for ring terminal lug
Fork terminal lug
Serrated washer
Flat washer
M5 screw
Set for connecting fork terminal lug to pipe
M16 or M20 bolt.
Not included in kit
Flat washer M16&M20
(2 units each size)
Included in kit
Serrated washer M16&M20
(2 units each size).
Included in kit
M16 or M20 nut
Not included in kit
15
Arad Ltd. 1923900 Dalia, ISRAEL
Tel: (972)4-9897911 Fax: (972)4-9897965 w w w . a r a d . c o . i l
March 2015
Innovation through precision,
quality and performance