APPLICATION TYPE DIAGRAM
SEE INSTALLATION MANUAL
FOR COMPLETE INSTRUCTIONS
INSTALL IN ACCORDANCE WITH LOCAL CODES.
ONE OR TWO TEMPERATURE
TWO HEATERS
WITH OR W/O MIXING VALVE
TWO PREHEATERS WITH BOOSTER
HEATER WITH OR W/O BUILDING
RECIRCULATTION
OIL FIRED TANK TYPE
COF-199 THRU 700
MUST BE IDENTICAL HEATERS
TWO HEATERS WITH OR WITHOUT MIXING VALVE
OUTLET
(BOOSTED
TEMPERATURE)
CAUTION:
IF BUILDING COLD WATER SUPPLY HAS A BACKFLOW
PREVENTER, CHECK VALVE OR WATER METER WITH
CHECK VALVE, PROVISIONS FOR THERMAL EXPAN-
SION OF WATER IN THE HOT WATER SYSTEM MUST BE
PROVIDED.
* PIPE RELIEF VALVE TO OPEN DRAIN.
** 120°F SHOULD BE MINIMUM AND 140°F TO 150°F
SHOULD BE MAXIMUM TEMPERATURE OF WATER
STORED IN PRE-HEATER.
SEE PAGE A305.0 FOR MANIFOLD KITS.
MUST BE IDENTICAL HEATERS
TWO PRE-HEATERS WITH BOOSTER HEATER
Revised March 1996 A 309.0
MEDIUM TEMPERATURE
ONE HEATER WITH
AUXILIARY STORAGE TANK
FORCED CIRCULATION WITH
OR W/O BUILDING RECIRCULATION
OIL FIRED TANK TYPE
COF-199 THRU 700
APPLICATION TYPE DIAGRAM
SEE INSTALLATION MANUAL
FOR COMPLETE INSTRUCTIONS
INSTALL IN ACCORDANCE WITH LOCAL CODES.
VERTICAL STOTRAGE TANK
CAUTION:
IF BUILDING COLD WATER SUPPLY HAS A BACKFLOW
PREVENTER, CHECK VALVE OR WATER METER WITH
CHECK VALVE, PROVISIONS FOR THERMAL EXPAN-
SION OF WATER IN THE HOT WATER SYSTEM MUST BE
PROVIDED.
* PIPE RELIEF VALVE TO OPEN DRAIN.
HEATER THERMOSTATS SHOULD BE SET AT LEAST 5°
HIGHER THAN TANK TEMPERATURE CONTROL.
A 310.0
© A. O. Smith Corp., 1996
HORIZANTAL STORAGE TANK
Printed in U.S.A.