Broadata LBH-H/O-EAD-R-ICP User manual
Add to My manuals47 Pages
Broadata LBH-H/O-EAD-R-ICP is a Link BridgeTM HBaseT/HDMI Receiver System with External Audio and Inline Control Processor. It provides in-line control I/O paths, supports video resolutions up to 1080p 60Hz and 1920 x 1200@60Hz, and 4K@30Hz.
Key Features:
- HDBT or HDMI receiver with multiple control I/O ports
- HDMI, audio, IR, and RS-232 up to 100 meters over 1 CAT-5e/6 cable
- Embedded audio extraction
- EDID pass-through support
- Control I/O ports with RS-232, Relay, Digital I/O, IR, and Ethernet
- Control and monitor AV devices using Ethernet or RS-232
Possible Use Cases:
advertisement
LBH-H/O-EAD-R-ICP
L
INK
B
RIDGE
TM
HB
ASE
T/HDMI
R
ECEIVER
S
YSTEM WITH
E
XTERNAL
A
UDIO
AND
I
NLINE
C
ONTROL
P
ROCESSOR
BCI reserves the right to make changes to the products described herein without prior notice or consent. No liability is assumed as a result of their use or application. All rights reserved.
©2015 Broadata Communications, Inc.
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
SAFETY INSTRUCTIONS AND
COMPLIANCE DECLARATIONS
PLEASE OBSERVE THE FOLLOWING SAFETY
PRECAUTIONS
SURGE PROTECTION DEVICE RECOMMENDED
This product contains sensitive electrical components that may be damaged by electrical spikes, surges, electric shock, lightning strikes, etc. Use of surge protection systems is highly recommended in order to protect and extend the life of your equipment.
Broadata Technical Support, [email protected]
3
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
TABLE OF CONTENTS
1.0 PRODUCT DESCRIPTION .............................................. 5
2.0 OPERATION CONTROL AND FUNCTIONS ................... 6
2.1 RECEIVER EXTENDER FRONT AND REAR PANEL ..... 6
2.2 ICP FRONT AND REAR PANEL ..................................... 7
3.0 CONNECTOR PINOUT ASSIGNMENT ........................... 8
3.1 EXTENDER ...................................................................... 8
3.1.1 SERIAL DATA INTERFACE ............................................ 8
3.1.2 STATUS LEDS ............................................................... 9
3.2 ICP ................................................................................. 10
3.3 LB-KP8 ........................................................................... 11
4.0 LB-ICP WEB SERVER DESCRIPTION ......................... 13
5.0 SPECIFICATIONS ........................................................... 39
6.0 SERVICE PROCEDURE ................................................ 42
6.1 REPLACEMENT POLICY .............................................. 42
6.2 RETURN AND REPAIR SERVICE ................................. 42
7.0 LIMITED WARRANTY .................................................... 43
4 Broadata Technical Support, (800) 214-0222
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
1.0 PRODUCT DESCRIPTION
Overall
•
A selectable HDBT or HDMI receiver with multiple control I/O ports
•
Provides in-line control I/O paths
Receiver
•
Receive HDMI, audio, IR, and RS-232 up to 100 meters over 1
CAT-5e/6 cable
•
Supports video resolutions up to 1080p 60Hz and
1920 x 1200@60Hz, as well as 4K@30Hz
•
Supports HDMI w/embedded audio extraction
•
EDID pass-through support, automatically detects the factory setting of the connected display
Control
•
Control I/O ports contain:
- two (2) RS-232
- two (2) Relay
- two (2) Digital I/O
- one (1) IR
- one (1) Ethernet
•
Control and monitor AV devices using a standard Ethernet network (Smart phone or PC) or RS-232 (keypad)
•
Front panel port status indicators
•
User friendly customizable control configurations via built-in web server
ORDERING INFORMATION
LBH-H/O-EAD-R-M-SC-ICP Link Bridge HDBT/HDMI Receiver w/Control I/O Ports
Broadata Technical Support, [email protected]
5
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
2.0
OPERATION CONTROLS AND FUNCTIONS
ICP
1
1 2
2
1 2
I / O
1
2
1
2
RS232
REM
IR
1
1
2
2
RELAY AUX
Extender
SPDIF L / R
PWR/ LINK
D A TA
Out
AUDIO
HDMI IN
HDMI OPT
AUTO
LBH-H/O-EAD-RX-ICP HDMI OUT
Front
Extender ICP
Rear
LINK
+24VDC
1.25 A
1
ON
SW
1
CONFIG LAN
RESET
6
2.1 Receiver Extender Front and Rear Panel
1
1 2
2
1 2
I / O
1
2
1
2
RS232
REM
IR
1
1
2
2
RELAY
1
4
8
9
2
3
5
6
AUX
SPDIF
AUDIO
L / R PWR/ LINK
HDMI IN
D A TA
Out
EDID
Loc
HDMI OPT
Rem
AUTO
LBH-H/O-EAD-RX-ICP
HDMI OUT
Front
10
12
13
7
11
Rear
LINK
+24VDC
1.25 A
1
ON
SW
1
CONFIG LAN
RESET
14
15
1.
Power/Link:
The red LED indicates the unit is powered up.
The green LED indicates that the unit has a good HDBT connection.
Broadata Technical Support, (800) 214-0222
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
2.
HDCP LED:
The blue LED is lighted when HDCP video is present. The blue LED blinks when non-HDCP video is present.
3.
SPDIF LED:
Lighted when corresponding SPDIF audio is active.
4.
DATA LEDs:
Lighted when corresponding input or output ports are active.
5.
L/R LED:
Lighted when corresponding audio is active.
6.
DATA:
RS-232 pass-through data connector.
7.
IR:
IR pass-through IR connector.
8.
SPDIF:
SPDIF audio output connector.
9.
L/R:
L/R audio output connector.
10. HDMI IN:
HDMI video input connector.
11. HDMI OUT:
HDMI video output connector.
12. EDID Selection:
Select Local or Remote EDID (for HDMI IN)
13. Input Video Selection:
Reserved.
14. HDBT:
HDBT CAT-5e/6/7 cable connector.
2.2 ICP Front and Rear Panel
1
2
5
6 8
1
1 2
2
1 2
I / O
1
2
1
2
RS232
REM
IR
1
1
2
2
RELAY
9
ICP Front
AUX
SPDIF
AUDIO
L / R
PWR/ LINK
HDMI IN
D A TA
Out
EDID
Loc
HDMI OPT
Rem
AUTO
LBH-H/O-EAD-RX-ICP HDMI OUT
3
4
7
13
ICP Rear
LINK
+24VDC
1.25 A
10
ON
1
SW
1
CONFIG
11
12
14
15
LAN
RESET
16
17
1.
Digital I/O:
Digital input/output ports.
2.
Digital I/O LEDs:
Light when the corresponding ports are active high.
Broadata Technical Support, [email protected]
7
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
3.
RS-232:
Serial port to control devices.
4.
RS-232 LEDs:
Light when the corresponding RS-232 ports are active.
5.
REM LED:
Light when the unit is set as a remote unit.
6.
IR LED:
Light when the IR out are active.
7.
RELAY LED:
Light when the corresponding, normally open pins, are closed.
8.
RELAY:
Normally open and normally closed relay ports.
9.
AUX-In and AUX-Out:
Reserved.
10. DC24V:
DC power input connector.
11. IR Out:
IR blaster port.
12. SW:
The unit configuration dip switch
13. IR Learner:
Built-in IR receiver for IR learning.
14. IR Learner LED:
Lighted when the unit is IR learning mode.
15. CONFIG:
Configuration/keypad port
16. LAN:
Ethernet connector.
17. RESET:
Press the button to reset the device back to factory default settings.
3.0 CONNECTOR PINOUT ASSIGNMENT
3.1 Extender
3.1.1 Serial Data Interface
Each LBH-H/O-EAD-R-ICP unit can be used for RS-232 and
IR interface.
RS-232/ IR Data
The LBH-H/O-EAD-R-ICP transmits two channels of data signals. Follow the procedures for installing data terminal devices.
1. Label and connect one serial data cable to the user’s
RS-232 or IR device.
8 Broadata Technical Support, (800) 214-0222
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
2. Connect the other end of this cable to the front panel data terminal block connector on the
LBH-H/O-EAD-R-ICP (see below).
RS-232/IR Terminal block pinout
3.1.2 Status LED’s
Additional status LED’s are provided for the user to indicate the presence of HDCP video, audio presence and data presence. These are to assist the user in identifying right from the front panel whether a given signal is present for transmission and aid in the troubleshooting process if a given signal is missing.
HDCP LED: Will be solid LED when video input has a HDCP. It will blink when video input does not have HDCP.
1
1 2
2
1 2
I / O
1
2
1
2
RS232
REM
IR
1
1
2
2
RELAY
Data in and Data out LED:
It will be on when the unit detects data signal.
AUX
SPDIF
AUDIO
L / R
PWR/ LINK
HDMI IN
D A TA
Out
EDID
Loc
HDMI OPT
Rem
AUTO
LBH-H/O-EAD-RX-ICP HDMI OUT
SPDIF & L/R detect LED.
It will be on when the unit detect the audio input signal.
Broadata Technical Support, [email protected]
9
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
3.2 LB-ICP
IR TX LED (On=IR TX
Front
GND
10 Broadata Technical Support, (800) 214-0222
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
IR OUT for external emitter
IR detector behind holes
Rear
DIP SW
Position 1: Local/Remote
(Local=OFF)
Position 2: Reserved
Position 3: Reserved
Position 4: Reserved
IR Learn LED
(ON in IR
Learn mode
CONFIG/Keypad
1. +12V keypad power
2. RS-232 IN
3. RS-232 OUT
4. GND
RJ-45
1 - TX+
2 - TX-
3 - RX+
4 - N/C
5 - N/C
6 - RX-
7 - N/C
8 - N/C
Reset button: push to reset to default settings
3.3 LB-KP8/LB-KP4
Rear
Control
RJ-45
Pin 1: RS-232 OUT
Pin 2: RS-232 IN
Pin 3: --no connect--
Pin 4: +12v
Pin 5: +12v
Pin 6: --no connect--
Pin 7: GND
Pin 8: GND
Broadata Technical Support, [email protected]
11
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
The cable connection between LB-KP8 and LB-ICP is shown below.
+12VDC
IR Out
IR
Learner
1
ON
SW
1
CONFIG LAN RESET
1. White/Orange
2. Orange
3. White/Green
4. Blue
5. White/Blue
6. Green
7. White/Brown
8. Brown
Standard RJ45
Termination T-568B
12 Broadata Technical Support, (800) 214-0222
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
4.0 LB-ICP WEB SERVER DESCRIPTION
Introduction
The ICP Web Server provides user friendly and intuitive web pages to configure the virtual keypad and automation functions within the ICP. It also provides web pages to manage the IR Learner and IR code import.
A standard web browser can be used to access the web pages.
Accessing Web Server
The IP address of the ICP must be obtained in order to access the Web
Server. There are 2 ways to obtain the IP address of an ICP.
1) Use the
IPCONFIG
command in the Configuration Port
Command Line Interface to display the unit’s IP address.
2) Use the
BCI PC Configuration Program
(see Appendix)
Type in the unit’s IP address in the web browser. The
ICP Virtual
Keypad
page will be displayed. All 8 keys of the Virtual Keypad are unprogrammed by default. The keys are configured in the
Configure
Key Action
page.
Broadata Technical Support, [email protected]
13
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
Before configuring the
Virtual Keypad
, the system first needs to be set up using the
Configure System
page. On the top menu bar, click
Configure
and then click
System.
This brings up the ICP Login page.
In the ICP Login type in
admin
for the Userid and
admin
for the Password and then click
Sign in
button. The
Configure System
page will appear.
See the following section for
Configure System
page details. Once logged in, the user is free to open any of the
Configure
or
Settings
pages. The default Password can be changed using the
BCI Product
Configuration
program.
14 Broadata Technical Support, (800) 214-0222
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
Configure System
The
Configure System
page is used to configure the network keypad, virtual keypad, RS-232 channels, Digital IO channels and remote unit types.
On the top menu bar, click
Configure
and then click
System.
The following page will be displayed.
Broadata Technical Support, [email protected]
15
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
Local Unit
The first two lines in this panel show the Local unit type and software version. Below that is the address setup and status for the Network
Keypad. The next two pull down menus are for selecting the virtual keypad size and enabling Auto Action Triggers. The last line shows the link status.
Network Keypad Address
: Enter the IP address of the network keypad
(LB-KP8E or LB-KP16E) if one is present in the system. Use the
BCI
Product Configuration
program to discover the network keypad’s IP address.
Network Keypad Status
: Shows type of network keypad connected to ICP.
Virtual Keypad Size
: Select
8 keys
or
16 keys
. 8 keys option: maximum of 10 actions per key. 16 keys option: maximum of 5 actions per key.
Auto Action Triggers
: Select
Enable
to enable the auto action triggers defined in the
Configure Auto Action
page. Select
Disable
to disable all auto action triggers.
Link Status
: Shows status of link with remote unit.
Local Unit RS-232 Options
This panel is used to configure the local RS-232 channels.
Channel:
Select channel 1, 2, 3 (Local Pass-through) or 3 (Remote
Pass-through).
Channel 1/2
: RS-232 control channels.
Channel 3 (Local Pass-through)
: RS-232 pass-through or control channel. This channel defaults as a control channel. See
Pass-through
Channel
below to change to pass-through channel.
16 Broadata Technical Support, (800) 214-0222
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
Channel 3 (Remote pass-through)
: RS-232 pass-through channel on the remote unit.
Note: This channel is not available if the remote unit is the
LBx-H/DP-EAD-T.
Baud Rate
: Select a baud rate from 9600 to 115200 baud.
Flow Control
: Select
On
to enable flow control and
Off
to disable flow control. Flow control is available only on Channel 1. If flow control is enabled, Channel 2 is no longer available.
End of Line Pattern
: Select CR, CR+LF or None for end of line termination.
Local Unit Digital IO Options
The 3 pull down menus in this panel are used to configure the Digital IO settings. Digital IOs are inputs by default and show up as triggers in the
Configure Auto Actions
page.
Digital IO Channel
: Select channel
1
or
2
.
Digital IO Direction:
Select channel as a digital
Input
or
Output
.
If the Digital IO Direction is set to
Input
, there is an option for
Pullup
Resistor
.
Pullup Resistor
: Select
Enable
or
Disable
pull-up resistor.
If the Digital IO Direction is set to
Output
, there is an option for
Digital
Output Mode
.
Digital Output Mode
: Select
TTL
for a 5V compatible TTL type output or
Open Collector
for an open collector type output. An open collector type output can be used to implement a contact closure type output.
For example, if a digital output is set to
Open Collector
, setting the
Digital Output State to
1 (High)
will emulate a switch closure to ground
.
Setting the Digital Output State to 0 (Low) will emulate a switch being open. The Open Collector output also has an option for a Pullup Resistor.
Broadata Technical Support, [email protected]
17
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
Remote Unit
This panel enables the connection with the remote unit and selects the remote unit type.
Pass-through Channel
: Select
ICP Mode
to enable ICP control of the local and remote pass-through channels. Select
Pass-through mode
to connect the local pass-through channel with the remote pass-through channel.
Remote Unit
: Select the remote unit type. The available remote unit types are
LBx without ICP
and
LBx-H/DP-EAD-T.
Configure Key Action
The
Configure Key Action
page is used to configure the keys virtual on the virtual keypad. On the 8-key keypad, each function key can be defined as a macro for up to 10 different actions. On the 16-key keypad, each function key can be defined as a macro for up to 5 actions. The available actions are Relay, Digital Output, RS-232, IR, Telnet, Video
Input Select and Keypad. Note: Digital Output actions are only available if Digital IOs are configured as outputs in the
Configure System
page..
On the top menu click
Configure
and then click
Key Action
. The following page will be displayed.
Function Key
: Select the function key F1 through F8 to be defined.
18 Broadata Technical Support, (800) 214-0222
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
Function Key Label
: Type in a label name for the selected function key.
Function Key Mode
: Select
Standard
for a “momentary” type key.
Only one action is assigned to a
Standard
key. Select
Toggle
for a
“toggle” type key. A Toggle key has two states:
Press
and
Release
.
One set of actions is assigned to the
Press
state and another set of actions is assigned to the
Release
state.
Command Action
: Select the action number to be defined. Action 1 through Action 10 can be defined.
Spacing
: Enter the delay desired before the command action.
Action Type
: Select the action type. Available types are
None
,
Relay
,
Digital Output
,
RS-232
,
IR, Telnet
,
Video Input Select and
Keypad
.
Relay Options
Relay Channel:
Select the relay channel
1
or
2
.
Relay State
: Select the relay channel state,
On
(energized) or
Off
(de-energized).
Broadata Technical Support, [email protected]
19
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
Digital Output Options
Digital Output Channel:
Select the digital output channel
1
or
2
.
Note: this option is not available if both Digital IO channels are set to
Inputs in Configure System page.
Digital Output State
: Select the digital output state:
1 (High)
or
0
(Low)
.
20 Broadata Technical Support, (800) 214-0222
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
RS-232 Options
RS-232 Channel:
Select channel 1, 2, or 3 (Remote).
Transmit String
: Type in the text string to be transmitted. Strings are terminated with CR, CR+LF or no termination, depending on the selection made in Configure System page. Characters enclosed by <> will be treated as hex. For example to transmit 00h enter <00>.
Broadata Technical Support, [email protected]
21
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
IR Options
IR Preset
: Select from list of IR commands stored in memory. IR commands must be learned via Configure IR Code page or imported via Configure IR Import page.
22 Broadata Technical Support, (800) 214-0222
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
Telnet Options
Telnet ID:
Select the telnet connection desired for telnet actions. The connections defined in Configure Telnet Connections page appear in this menu.
Commands
: Enter the command strings to be transmitted. Up to 4 different command strings can be defined.
Select the check box if the response to one of the commands is to be used as an auto trigger.
Broadata Technical Support, [email protected]
23
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
Video Input Select Options
Video Input Select
: Select Auto, HDMI (local), HDMI (remote) or
DisplayPort (remote).
Auto
: Select Auto input mode. Video input will be selected automatically based on input priority. The priority of the inputs in descending priority:
HDMI (remote), DisplayPort, HDMI (local). For example if sources are plugged into the remote HDMI input and local HDMI input, the remote
HDMI input will be selected. If the remote HDMI source is unplugged, the video output will switch to the local HDMI input.
HDMI (local)
: Select local HDMI video input. Auto mode is disabled.
HDMI (remote)
: Select remote HDMI video input. Auto mode is disabled.
DisplayPort (remote)
: Select remote DisplayPort video input. Auto mode is disabled.
24 Broadata Technical Support, (800) 214-0222
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
Keypad Action
Action:
Select Press, Release, Press (no actions), Release (No actions) or Release All Toggle Buttons
Press
: This action presses the key selected in Key Number menu. All associated actions for the key press state will be executed.
Release
: This action releases the key selected in Key Number menu.
All associated actions for the key release state will be executed.
Press (no actions will be triggered)
: This action presses the key selected in Key Number menu, but none of associated actions for the key press state will be executed.
Release (no actions will be triggered)
: This action releases the key selected in Key Number menu, but none of associated actions for the key release state will be executed.
Release All Toggle Buttons
: This action sets all toggle keys to the release state without executing any actions.
Key Number:
Select a key number for the selected keypad action.
Broadata Technical Support, [email protected]
25
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
Configure Auto Action
The
Configure Auto Action
page is used to configure a set of auto actions based on a selected trigger. Available triggers are Video Detects
(Local HDMI, Remote HDMI and DisplayPort), Digital Input 1, Digital
Input 2, RS-232 Channel 1, RS-232 Channel 2, Telnet Trigger 1 and
Telnet Trigger 2. The available actions are Relay, RS-232, IR, Telnet,
Video Input Select and Keypad. Digital Output actions are only available if Digital IOs are configured as outputs in the
Configure System
page.
All auto triggers work independently and can be triggered simultaneously.
On the top menu click
Configure
and then click
Auto Actions
.
The following page will be displayed:
Trigger
: Select the auto action trigger. Available triggers are Video
Detect (Local HDMI), Video Detect (Remote HDMI), Video Detect
(DisplayPort), Digital Input 1, Digital Input 2, RS-232 Channel 1, RS-
232 Channel 2, Telnet Trigger 1 and Telnet Trigger 2.
Trigger When
: For Digital Inputs, select
High
for the High signal trigger.
Select
Low
for the Low signal trigger. For the Video Detect lines, the trigger options are when Video Detect line is
Asserted
or
De-asserted
.
For RS-232 triggers, enter the trigger string. Up to 2 trigger strings can be defined for each RS-232 channel. For Telnet triggers, select the telnet trigger and enter the trigger string. Up to 2 trigger strings can be defined for each Telnet trigger.
Note: A telnet trigger needs to be associated with one or more telnet actions. The check box under the Commands box in Configure Key
Action, Telnet Options panel must be selected.
26 Broadata Technical Support, (800) 214-0222
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
Allow delayed actions checkbox: Select this box to allow a set of delayed actions to be overridden by the opposing trigger. For example: video detect asserted trigger overrides video detect de-asserted trigger actions.
Refer to the
Configure Key Action
sections for the rest of the pull down menu descriptions.
Configure IR Code
The
Configure IR Code
page is used to learn and manage IR codes in the ICP. To learn an IR code, type in the label of the IR code in
New
Label
and click the
Learn
button. Once IR Learn mode is initiated, the user needs to present an IR signal to the IR receiver port within 30 seconds. If a valid IR code is not presented within 30 seconds, the IR learn process will timeout and the process will need to be re-initiated.
After an IR code is learned successfully, it will be stored in memory and appear in the
IR Preset
drop down menu. To test a learned IR code, select the IR code from the IR Preset menu and click
Test
button.
Verify that the IR code works correctly on the target device. To delete an IR code from the IR Preset menu, select the desired IR code and click the
Delete
button.
On the top menu click
Configure
and then click
IR Code
.
The following page will be displayed:
Broadata Technical Support, [email protected]
27
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
Configure IR Code Import
The
Configure IR Code Impor
t page is used to import an IR pronto code. Once a code is imported, it will be stored in memory and is available as an IR Preset. It can be tested in the
Configure IR Code
page.
On the top menu click
Configure
and then click
IR Code Import
.
The following page will be displayed:
New Label:
Enter a label for the IR code.
Pronto Code
: Enter the pronto code to be imported.
28 Broadata Technical Support, (800) 214-0222
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
Configure Telnet Connections
The
Configure Telnet Connections
page is used to setup the telnet connections for telnet key actions and auto actions. There are 2 telnet connection types: Persistent and Action. The Persistent connection is a permanent telnet connection between the ICP and the remote device.
This type of connection is typically used for monitoring telnet status messages and triggering auto actions. Up to 2 Persistent connections can be defined. The Action connection is a temporary telnet connection.
This type of connection is typically used for normal telnet actions. Up to
8 Action connections can be defined.
On the top menu click
Configure
and then click
Telnet Connections
.
The following page will be displayed:
Connection Type
: Select Persistent or Action.
Telnet ID
: Select Telnet-1, 2 (Persistent type); Telnet-3, 4, 5, 6, 7, 8,
9, 10 (Action type).
Broadata Technical Support, [email protected]
29
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
Telnet Connection Label
: Enter a label for the telnet connection.
Connection Status
: This box shows the status of a persistent connection.
Telnet Options
IP Address
: Enter IP address of telnet server.
IP Port
: Enter port number of telnet server. The default port number is
23.
UserName Prompt
: Enter username prompt from telnet server. Leave blank if there is no username prompt.
UserName
: Enter user name required for log in. Leave blank if there is no username.
Password Prompt
: Enter password prompt from telnet server. Leave blank if there is no password prompt.
Password
: Enter password required for log in. Leave blank if there is no password.
Command Prompt
: Enter command prompt from telnet server. Only the last 9 characters of the command prompt are needed. Leave blank if there is no command prompt.
Note: Select check box below if string is used as a one-time only greeting.
Auto Trigger
: Select Telnet Trigger 1 or Telnet Trigger 2. This selection associates the telnet connection with Telnet Trigger 1 or Telnet Trigger
2 used in Auto Actions.
Tx Spacing
: Enter the delay (seconds) before command is transmitted in Telnet Actions. Enter 0 if no delay is desired.
30 Broadata Technical Support, (800) 214-0222
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
Configure Combination Triggers
The
Configure Combination Triggers
page is used to define up to 2 different combination triggers. Each combination trigger supports the logical OR or AND function of up to 3 digital input or video detect trigger events. A combination trigger only supports a single logical function,
OR or AND. A combination trigger is Asserted when the trigger statement evaluates to true. Once a combination trigger is defined, it will appear in the Configure Auto Action Trigger menu.
Combination Trigger ID
: Select Combination Trigger 1 or 2.
Trigger Label
: Enter name of combination trigger.
Trigger Event 1/2/3
: Select the desired trigger from pull-down menu.
Trigger When 1/2/3
: Select High or Low for digital input triggers.
Select Asserted or De-asserted for video detect triggers.
OR/AND
: Select the logical OR or AND function.
Broadata Technical Support, [email protected]
31
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
View and Manage Settings
The
View and Manage Settings
page shows the current settings of the
Key Action Definitions
,
Auto Action Definitions, IR Code
Definitions, Telnet Definitions
and
Combination Triggers
. Click the
Details
button next to the associated Definitions to display the settings details. ICP settings are saved to a file on the local PC using the
Save
Settings
button. ICP settings are restored from a file using the
Restore
Settings
button.
On the top menu click
Settings
and then click
View and Manage
Settings
. The following page will be displayed:
32 Broadata Technical Support, (800) 214-0222
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
Click the
Key Action Definitions Details
button and the following will be displayed:
Broadata Technical Support, [email protected]
33
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
Click the
Auto Action Definitions Details
button and the following will be displayed:
34 Broadata Technical Support, (800) 214-0222
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
Click the
IR Code Definitions Details
button and the following will be displayed:
Broadata Technical Support, [email protected]
35
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
Click the
Telnet Definitions Details
button and the following will be displayed:
36 Broadata Technical Support, (800) 214-0222
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
Click the
Combination Triggers Details
button and the following will be displayed:
Broadata Technical Support, [email protected]
37
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
Examples
Example #1: This example configures the F1 key on the virtual keypad as a toggle key to turn on/off Relay channel 1.
On the top menu click
Configure
and then
Key Action
.
Configure F1 Key toggle-press action, to turn Relay channel 1 On as follows:
Click
Submit Changes.
38 Broadata Technical Support, (800) 214-0222
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
Configure F1 Key toggle-release action, to turn Relay channel 1 Off as follows:
Click
Submit Changes.
On the top menu click
Keypad
. The following virtual keypad should be displayed:
Broadata Technical Support, [email protected]
39
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
5.0 SPECIFICATIONS
VIDEO (TRANSMISSION)
HDMI
Connector
Protocol
Up to 1080p @ 60Hz or
1920 x 1200 @ 60Hz or 4K@30Hz
HDMI Female Plug
DDC/EDID/HDCP Capable
AUDIO OUTPUT (TRANSMISSION)
Signal Format L/R Analog and SPDIF
Audio Output Connector 3.5mm Stereo
RS-232 (TRANSMISSION)
Data Rate
Connector
Up to 57.6kbaud
Terminal Block
IR (TRANSMISSION)
Data Rate
Connector
HDBT (TRANSMISSION)
Cable Type
Number of Cables
Connector/Distance
ETHERNET (CONTROL)
Channel Capacity
Connector
Data Rate
Protocols
30-60KHz
Terminal Block
CAT-5e/6 or higher
1
RJ-45/Up to 100m
1
Female RJ-45 (integrated Activity and
Link LEDs)
10/100Base-T, half/full duplex with autodetect
DHCP, HTTP, TCP/IP, UDP/IP,
AUTOIP, Telnet
40 Broadata Technical Support, (800) 214-0222
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
RS-232 (CONTROL)
Channel Capacity
Baud Rate
2 (no flow control) or 1 (with RTS/
CTS flow control)
2400 to 115200 baud (9600 baud=default), 8 data bits, 1 stop bit, no parity
Terminal block Connector
DIGITAL I/O (CONTROL)
Channel Capacity
Digital Input
Digital Output
2 digital input/output (configurable)
Input voltage range: 0 to 5 VDC
Programmable pullup: 2.2k ohms to
+5 VDC Threshold low to high: 2 VDC
Threshold high to low: 0.8 VDC
Output voltage high: 3 VDC min
Output voltage low: 0.55 VDC max
(64 mA sink max) Programmable open collector
Terminal block Connector
IR (CONTROL)
Channel Capacity
Connector
Carrier Frequency
IR Learning
RELAY (CONTROL)
Channel Capacity
Relay Contact Rating
Connector
1 in and 1 out
3.5 mm jack (for IR blaster)
30 kHz to 60 kHz (Output) 30 kHz to
60 kHz (IR learning)
2 inches captive distance from panel
2 normally open/normally closed relays
24 VDC, 1A
Terminal block
Broadata Technical Support, [email protected]
41
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
PHYSICAL
Dimensions
Power Consumption
Operating Temperature
Humidity
8.36” (W) x 4.23” (D) x 1.12” (H)
24 VDC @ 1.25A
0 to 40-deg C
0 to 95%, non-condensing
42 Broadata Technical Support, (800) 214-0222
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
6.0 SERVICE PROCEDURE
6.1 Replacement Policy
Standard products found defective on arrival (DOA) will be replaced, based on availability, within 24 to 48 hours anywhere in the U.S. Please call Customer Service at
800-214-0222
for information.
6.2 Return/Repair Service
The Link Bridge LBH-H/O-EAD-R-ICP System contains no user serviceable components. If you have a problem with your unit, please contact the Customer Service Department. To facilitate our return/repair processing please contact Broadata
Communications, Inc. to obtain a Return Material Authorization
(RMA). Please include the following information:
•
•
•
• Product model number
Serial Number
Complete description of problem
Hardware installation description
Broadata Communications, Inc.
2545 West 237th Street, Suite K
Torrance, CA 90505
1-800-214-0222
(310) 530-1416
(310) 530-5958 (Facsimile) e-mail: [email protected]
Website: www.broadatacom.com
Broadata Technical Support, [email protected]
43
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
7.0 LIMITED WARRANTY
Broadata Communications, Inc. (BCI) warrants, for a period of one year from date of shipment, each product sold shall be free from defects in material and workmanship. BCI will correct, either by repair, or at
BCI’s election, by replacement, any said products that in our sole discretion prove to be defective and are returned to the manufacturing location within 30 days after such defect is ascertained. All warranties are limited to defects arising under normal use and do not include malfunctions or failure resulting from misuse, abuse, neglect, alterations, electrical power problems, usage not in accordance with product instructions, improper installation, or damage determined by BCI to have been caused by the Buyer or repair made by a third party. Limited warranties granted on products are to the initial customer end-user and are not transferable. OUR LIABILITY UNDER THIS WARRANTY SHALL
IN ANY CASE BE LIMITED TO THE INVOICE VALUE OF THE
PRODUCT SOLD AND BCI SHALL NOT BE LIABLE TO ANYONE FOR
CONSEQUENTIAL OR INCIDENTAL DAMAGES ARISING FROM THE
USE OF ITS PRODUCTS OR THE SALE THEREOF. We make NO
WARRANTY AS TO THE MERCHANTABILITY OF ANY GOODS, OR
THAT THEY ARE FIT FOR ANY PARTICULAR PURPOSE OR END
APPLICATION NOR DO WE MAKE ANY WARRANTY, EXPRESSED
OR IMPLIED OTHER THAN AS STATED ABOVE.
44 Broadata Technical Support, (800) 214-0222
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
Broadata Technical Support, [email protected]
45
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
46 Broadata Technical Support, (800) 214-0222
LBH-H/O-EAD-R-ICP User Manual
Link Bridge
TM
HBaseT/HDMI Receiver System w/External Audio and Inline Control Processor
Broadata Technical Support, [email protected]
47
Broadata Communications, Inc.
2545 West 237th Street, Suite K
Torrance, CA 90505
1-800-214-0222
(310) 530-1416
(310) 530-5958 (Facsimile) e-mail: [email protected]
Website: www.broadatacom.com
60000-LBHHOEADRICPv2.20
advertisement
Related manuals
advertisement
Table of contents
- 4 1.0 PRODUCT DESCRIPTION
- 5 2.0 OPERATION CONTROL AND FUNCTIONS
- 5 2.1 RECEIVER EXTENDER FRONT AND REAR PANEL
- 6 2.2 ICP FRONT AND REAR PANEL
- 7 3.0 CONNECTOR PINOUT ASSIGNMENT
- 7 3.1 EXTENDER
- 7 3.1.1 SERIAL DATA INTERFACE
- 8 3.1.2 STATUS LEDS
- 9 3.2 ICP
- 10 3.3 LB-KP
- 12 4.0 LB-ICP WEB SERVER DESCRIPTION
- 38 5.0 SPECIFICATIONS
- 41 6.0 SERVICE PROCEDURE
- 41 6.1 REPLACEMENT POLICY
- 41 6.2 RETURN AND REPAIR SERVICE
- 42 7.0 LIMITED WARRANTY