Allied Telesis AT-RPS3204 Installation guide
Add to My manualsAllied Telesis AT-RPS3204 is a redundant power supply that provides backup power for Allied Telesis switches in case of a primary power supply failure. It can accommodate up to three additional AT-PWR3202 Power Supplies, providing redundant power for a total of four Allied Telesis switches. The AT-RPS3204 is designed for use in 19-inch racks and comes with two rack-mount brackets and 12 rack-mount bracket screws for easy installation. It also features two AC power connectors with retaining brackets and clips to secure the power cords.
advertisement
AT-RPS3204 Redundant Power Supply Installation Guide
Overview
The AT-RPS3204 powers an Allied Telesis switch if the switch’s main power supply fails. The AT-RPS3204 is shipped with one AT-PWR3202 Power Supply installed in slot A1, which can supply power for one switch. The AT-RPS3204 can accommodate up to three additional AT-PWR3202 Power Supplies, supplying redundant power for a total of four Allied Telesis switches.
Front
STATUS
AT-PWR3202
12VDC ,10A MAX
POWER
FAULT
187
A1 B2
B2
A2 B1
AT-PWR3202 Power Supply Slots
B1 A2 A1
ON
OFF
ON
OFF B2
AT-RPS3204
RPS OUTPUT B2
12VDC
AC INPUT B2/B1
100 - 240 VAC ~
RPS OUTPUT B1
12VDC
B1
ON
OFF A2
WARNING
This unit has more than one power input. To reduce the risk of electric shock, disconnect all power inputs before servicing unit.
RPS OUTPUT A2
12VDC
AC INPUT A2/A1
100 - 240 VAC ~
RPS OUTPUT A1
12VDC
A1
188
Back
Verifying Package Contents
Verify that the correct components are included in your package:
• AT-RPS3204 Redundant Power Supply
• Two rack-mount brackets
• 12 rack-mount bracket screws
• Two AC power cords
• Two power cord retaining clips
• One 21-pin D-combo connector cable
• This installation guide
If any item is missing or damaged, contact your Allied Telesis sales representative for assistance.
Warranty
The AT-RPS3204 Redundant Power Supply (RPS) has a Lifetime Year Warranty
(Five Years Power Supply and Fan). For detailed warranty information, see the www.alliedtelesis.com website.
Installing the AT-RPS3204 Redundant Power Supply
To install an AT-RPS3204 Redundant Power Supply (RPS), perform the following procedure:
1. Remove the RPS from its shipping package and store the package in a safe place. You must use the original shipping package if you need to return the
RPS to Allied Telesis.
*613-5061100 Rev C*
PN 613-50611-00 Rev. C 1
2. If you are installing the RPS in a rack, place the unit upside down on a level, secure surface. If you are not installing the RPS in a rack, go to step 5.
3. Use a flat-head screwdriver to remove the snap-on feet from the bottom of the power supply.
4. Turn the power supply over.
5. Locate the power cord retaining clips.
11. Install the second rack-mount bracket on the other side of the RPS, using the remaining rack-mount screws.
12. Mount the AT-RPS3204 in a 19-inch rack using standard screws (not provided).
193
131
6. Locate the retaining bracket on each side of the two AC power connectors on the back of the power supply.
PS OUTPUT
12VDC A2
AC INPUT A2/A1
100 - 240
VAC ~
RPS OUTPU
12VDC T A1 A1
Bracket
ON
OFF
7. With the “u” of the clip facing up, press the sides of the clip toward the center and insert the short ends into the holes in one of the retaining brackets.
PS OUTPUT
12VDC A2
AC INPUT A2/A1
100 - 240
VAC ~
RPS OUTPU
12VD
C
T A1
A1
ON
OFF
8. Repeat steps 6 and 7 to install the second retaining clip in the other retaining bracket.
9. Verify that the retaining clips are in the correct position.
PS OUTPUT
12V
DC A2
AC INPUT A2/A1
100 - 240
VAC
~
RPS OUTPU
12VDC T A1
A1
ON
OFF
10. Attach a rack-mount bracket to one side of the front of the RPS, using a # 1
Phillips screwdriver and six rack-mount screws provided in the package.
If you are not installing the unit in a rack, go to step 13.
192
Caution: Air vents must not be blocked and must have free access to room ambient air for cooling. E6
Warning: Operating Temperature. This product is designed for a maximum ambient temperature of 40° C. E7
All Countries: Install product in accordance with local and National
Electrical Codes. E8
Circuit Overloading: Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits might have on overcurrent protection and supply wiring.
Appropriate consideration of equipment nameplate ratings should be used when addressing this concern. E21
Warning: Mounting of the equipment in the rack should be such that a hazardous condition is not created due to uneven mechanical loading.
E25
If installed in a closed or multi-unit rack assembly, the ambient temperature of the rack environment may be greater than the room ambient temperature. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra). E35
Caution: Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. E36
Warning: Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuits (e.g., use of power strips). E37
Warning: High leakage current due to multiple power supplies.
Connection of each power cord to a separate branch circuit with proper earth connections is essential.
2 3
13. Verify that the On/Off switches for the power supplies marked A1 and A2 are in the Off (out) position.
RPS OUTPUT A1
12V
DC
A1
ON
OFF
194
14. Position the power cord retaining clip in the up position.
PS OUTPUT
12VDC A2
AC INPUT A2/A1
100 - 240
VAC ~
RPS OUTPU
12VDC
T A1 A1
ON
OFF
15. Plug the power cord into the AC power connector on the back of the power supply.
PS OUTPUT A2
12VDC
AC INPUT A2/A1
100 - 240
VAC ~
RPS OUTPU
12VDC
T A1
A1
ON
OFF
16. Secure the cord by lowering the power cord retaining clip.
PS OUTPU
12VDC T A2
AC INPUT A2/A1
100 - 240
VAC ~
RPS OUTPU
12VD
C
T A1
A1
ON
OFF
17. Plug the AC power cord into an AC wall outlet rated for at least 10 Amps.
18. Verify that the On/Off switches for the power supplies marked B1 and B2 are in the Off (out) position.
19. Repeat steps 13 through 17 to plug in the other power cord.
Note
DO NOT plug the second power cord into the outlet where the first power cord is plugged in unless the outlet is rated for at least 20 Amps.
4
20. Plug one end of the 21-pin D-combo connector cable into the connector labeled “RPS INPUT” on the rear panel of a switch.
RPS INPU
T
RPS INPU
T
400
For information about the pinouts for the 21-pin D-combo connector cable, see Appendix A of the switch’s installation guide.
21. Tighten the thumb screws on the connector.
401
22. Plug the other end of the cable into the connector labeled “RPS OUTPUT
A1” on the back of the RPS3204 unit.
ON
OFF
A2
RPS OUTPUT A2
12VDC
AC INPUT A2/A1
100 - 240
VAC ~
RPS OUTPUT A1
12VDC
A1
23. Tighten the thumb screws on the connector.
ON
OFF
A2
RPS OUTPU
12VDC T A2
AC INPUT A2/A1
100 - 240
VAC ~
RPS OUTPU
12VD
C
T A1 A1
ON
OFF
199
Note
An AT-PWR3202 Power Supply is NOT hot-swappable into and out of the
AT-RPS3204 Redundant Power Supply. To replace an AT-PWR3202 unit, first turn the power off using the appropriate On/Off switch and then remove and replace the power supply.
To remove the connector cable, turn the power off first using the appropriate On/Off switch.
5
24. Press the On/Off switch for the power supply marked A1 to move it to the On
(in) position.
ON
OFF
A2
RPS OUTPU
12VDC T A2
AC INPUT A2/A1
100 - 240
VAC
~
RPS OUTPU
12VDC T A1
A1
ON
OFF
The RPS LED on the front of the switch should be green. For more information about the RPS LED, refer to the switch’s installation guide.
To install and connect additional AT-PWR3202 Power Supplies, refer to the documentation that is shipped with that product.
Specifications
Item Specification
Dimensions (H x W x D) 43.7 x 440.5 x 360.6 mm (1.72 x 17.34 x 14.20 in.)
Operating Temperature 0° C to 40° C
Relative Humidity <85% noncondensing
Supply Voltage
RPS Input Voltage
RPS Output Voltage
12 V
100 - 240 V AC
12 V DC
Electrical, Safety, and Emissions Statements
This product meets the following standards:
U.S. Federal Communications Commission
Radiated Energy
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to operate this equipment.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing
Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
RFI Emissions
Immunity
EN 55022 Class A, EN61000-3-2, EN61000-3-3,
VCCI Class A
EN 55024
Warning: In a domestic environment this product may cause radio interference in which case the use may be required to take adequate measures.
Electrical Safety UL 60950 (
C
UL
US
), EN 60950 (TUV)
Copyright © 2008 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis, Inc. www.alliedtelesis.com.
6
advertisement