Overview

The PC1 (FG670) is a 10-Amp Power Controller for 110 VAC (FIG. 1).

AC1 (remote operation)

Pushbutton

Control Mode

DIP Switch

(front)

Installation Guide

PC1

Power Controller, 10 A (110 VAC only)

PCI Product Specifications (Cont.)

Enclosure: Metal with black matte finish.

Dimensions (HWD) 1.5" x 5.5" x 5.5" (3.81 cm x 13.97 cm x 13.97 cm)

Weight

Included

Accessories

Other AMX

Equipment

28 oz. (793.79 g)

Power Cord - 6 ft. (1.83 m), with 3-wire grounded plug.

AC-RK Rack Mount Kit (FG515)

WARNING: To reduce the risk of electric shock, equipment has a grounding type plug that has a third (grounding) pin. This plug will only fit into a grounding type outlet. If the plug does not fit into the outlet, contact a qualified electrician to install the proper outlet. Do not change the plug in any way.

Control Wiring

The 4-pin captive-wire connector on the rear panel (FIG. 2) provides wiring to

remote pushbuttons, switches, or relay contacts.

(rear)

4-pin captive-wire

Control Wiring connector

Switched Power Output socket AC Power Input

FIG. 1 PC1 Power Controller

The PC1 provides one switched power socket for up to 1200 watts of equipment power.

Note: The PC1 will work the NXC-I/O10 input/output control card.

Specifications

PCI (FG670) Product Specifications

Control Inputs

Power Outputs

Load Fuse

Power Input

Remote control contact and switch closure.

• 1 switched 3-wire socket.

• 110 VAC.

• 1200 watts total.

Internal 10A (load capacity).

• 105 to 125 VAC.

• 3 watts maximum.

Front Panel Components:

AC1 pushbutton • This latching on/off switch controls power to a switched socket.

• The LED in the pushbutton indicates that socket power is

ON.

DIP Switch Controls the AC1pushbutton operating mode.

Rear Panel Components:

Control

Switched Power

Output

• 4-pin captive-wire connector providing remote operation of the PC1.

• Terminals accept 24 - 12 AWG wire.

• Class 2 Circuit only.

• Socket for control of external equipment.

• Total max. power load = 1200 watts.

• An internal 10A load fuse is provided.

• 120 VAC, 1200W, 50/60 Hz.

AC Power Input • 3-conductor line cord providing 120 VAC power to the PS1 and switched power socket.

• 120 VAC, 10 Amp, 50/60Hz.

FIG. 2 4-Pin Captive Wire Control Wiring connector

The tables below list momentary/latching, and discrete on/off mode pinouts and functions.

Momentary/Latching Mode

Pin

1

2

3

4

Function

Unit Ground Input Contact Common

Channel 1 ON/OFF

N/C

N/C

Discrete On/Off Mode

Pin

1

2

3

4

Function

Unit Ground Input Contact Common

Channel 1 ON

N/C

Channel 1 OFF

DIP Switch Settings

The 4-position DIP Switch on the front panel is used to set the mode of

operation for the AC1 (remote operation) pushbutton (FIG. 3).

FIG. 3 DIP Switch and AC1 Remote Operation Pushbutton

The settings are shown below:

AC1 Momentary (Default)

Switch

1

2

3

4

Setting (Down = On)

ON

ON

ON

ON

1 2 3 4

AC1 Latching

Switch

1

2

3

4

Setting (Down = On)

OFF

OFF

ON

ON

Discrete ON/OFF

Switch

1

2

3

4

Setting (Down = On)

ON

OFF

OFF

ON

1 2 3 4

1 2 3 4

For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).

9/08

©2008 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX.

AMX reserves the right to alter specifications without notice at any time.

3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993 • www.amx.com

93-0670-01 REV: A

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement