SuperSerial™

ESP Multi-Interface Serial Hub

Product Installation Guide

PN 590-290-001A

August 2002

Part No.

210097

210098

210099

210100

210101

210102

210103

690252

690253

690254

790180

750133

Section 1 - Hardware

The Equinox SuperSerial Technology (ST) Ethernet Serial Provider 8-port

Multi-Interface (ESP-8 MI) Serial Hub can be installed in a local or remote

LAN to provide access for widely distributed RS-232, RS-422 or RS-485 serial devices. The ESP-8 MI is supported under Windows 2000, Windows

NT 4.0, Windows NT 3.51, OpenServer 5.0.5a or higher, UnixWare 7.0.1a or higher, Linux and AIX 4.3 and 5.1.

The ESP can be managed using EquiView Plus, the Equinox premier serial port management software, running on any Microsoft Windows host, or espdiag and espcfg for OpenServer, UnixWare, Linux or AIX.

The ESP-8 MI kit contains the items listed in Table 1.

Part No. Description

990407

590

750131

750130

650185

770379

8-port ESP-8 MI Unit

Installation Guide (this document)

RS-422 Loopback Connector

RS-232 Loopback Connector

Equinox SuperSerial Software CD

Two Wall-mount Brackets

Table 1. ESP-8 MI Kit Contents

Special-order accessories for the ESP-8 MI are available, as listed in Table 2.

Description

Modular Adaptors

RJ-45 to DB-25 RS-232 DTE Male Adaptor

RJ-45 to DB-25 RS-232 DTE Female Adaptor

RJ-45 to DB-25 RS-232 DCE Male Adaptor

RJ-45 to DB-25 RS-232 DCE Female Adaptor

RJ-45 to DB-9 RS-232 Male Adaptor

RJ-45 to DB-9 RS-232 Female Adaptor

RJ-45 to DB-25 RS-530 DTE Male Adaptor

Modular Cables

10-foot 10-wire Reversing Modular Cable

25-foot 10-wire Reversing Modular Cable

75-foot 10-wire Reversing Modular Cable

Rack Mount Shelf

Rack Mount Shelf

Wiring Starter Kit

Wiring Starter Kit includes seven adaptors (210097, 210098,

210099, 210100, 210101, 210102 and 210103) and a 10-foot

10-wire modular cable (690252)

Table 2. Special-Order Accessories

2

Equinox ESP Multi-Interface Serial Hub Product Installation Guide

Figure 1 shows the front of the ESP-8 MI. Table 3 describes the LEDs and buttons.

Figure 1. ESP Front View

Item Description

POWER The POWER LED is lit when the ESP is connected to a power source

ONLINE The ONLINE LED is lit (not blinking) when the ESP self-test and initialization procedures have completed successfully

LINK The LINK LED is lit when the ESP recognizes that is has a connection to the network

TRAFFIC The TRAFFIC LED blinks when there is network trafc

100MBps The 100MBps LED is lit when the ESP is connected to a

100 Mbps LAN

RESET

INIT

Pushing the RESET button reboots the ESP; for more information, see Section 1.4

Pushing the INIT button restores the ESP to factory defaults; for more information, see Section 1.4

Table 3. ESP LEDs and Buttons

Figure 2 shows the back of the ESP-8 MI and the port pin assignments.

Pin # RS-232

7

8

5

6

3

4

1

2

9

10

RTS

DTR

N/C

DCD

Rx

Tx

GND

N/C

N/C

CTS

RS-422

N/C

Tx-

Tx+

N/C

N/C

N/C

GND

Rx+

Rx-

N/C

RS-485

N/C

N/C

N/C

N/C

N/C

N/C

GND

Rx/Tx+

Rx/Tx-

N/C

MAC Address and

Serial Number

100-250 VAC, 50/60 Hz

0.5A

1 2 3 4 5 6 7 8

Warning - The power outlet should be installed

near the equipment and should be

easily accessible .

LAN

10/100 BaseT

Ethernet Connector

Figure 2. ESP Back View and Port Pin Assignments

NOTE: It is important that unused pins (labeled N/C) should not have wires attached to them. Floating wires could cause unbalanced noise, shorten overall distances and degrade performance.

3

Equinox ESP Multi-Interface Serial Hub Product Installation Guide

1.1 Hardware Installation

1. The MAC address is printed on a label afxed to the back of the unit above the LAN connector socket (see Figure 2). This address will be used as a Unit ID to distinguish different ESP units on the network.

Record the MAC address.

00 - 80 - 7D - _____ - _____ - _____

2. Attach a 10BaseT or 100BaseT LAN interface cable to the LAN connector on the back of the ESP. A CAT 5 cable is required for

100BaseT operation.

3. Power on the ESP by connecting the power cable to a power source.

WARNING: The power outlet should be installed near the equipment and should be easily accessible.

4. Install the ESP driver using the instructions in Section 2 for your target operating system.

5. Install or upgrade to EquiView Plus version 5.1 or higher from the

Equinox SuperSerial Software CD. EquiView Plus will help manage

ESP units on various networks.

If the ESP fails to boot ...

The ESP is very robust and there are few errors that can prevent the unit from correctly initializing and going online. However, if an error does occur, the ONLINE LED will blink a repeating pattern with discernible pauses. Count the number of blinks between pauses and make a note of this value. When you contact Technical Support, this information will help determine the cause of the initialization failure.

4

Equinox ESP Multi-Interface Serial Hub Product Installation Guide

1.2 RS-232 Device Cabling

Figures 3 through 5 show the pin assignments required for an RS-232 cable connection between the ESP RJ-45 ports and your devices.

To ESP RJ-45 Port

Clear to Send

N/C

N/C

Signal Ground

Transmit Data

Receive Data

Data Carrier Detect

N/C

DataTerminal Ready

Request to Send

..........

1

Pin #

10

9

8

5

4

3

2

1

7

6

.

Pin # To Terminal / Printer

4 Request to Send

1

2

20

7

3

8

6

5

Signal Ground

Receive Data

Transmit Data

Data Terminal Ready

Data Carrier Detect

Data Set Ready

Clear to Send

1 .....

o o o o o o o o

..

.

.

........

RJ-45 (Plug)

Cable End View

Figure 3. Cable Pin Assignments for ESP RJ-45 to Terminal/Printer

To ESP RJ-45 Port

Clear to Send

N/C

N/C

Signal Ground

Transmit Data

Receive Data

Data Carrier Detect

N/C

Data Terminal Ready

Request to Send

1

..........

Pin #

10

9

2

1

4

3

88

7

6

5 .

Pin #

7

3

4

6

1

8

5

2

To PC (DB-9)

Request to Send

Signal Ground

Receive Data

Transmit Data

Data Terminal Ready

Data Set Ready

Data Carrier Detect

Clear to Send

1

RJ-45 (Plug)

Cable End View

DB-9 (FEMALE)

Cable End View

Figure 4. Cable Pin Assignments for ESP RJ-45 to PC DB-9

To ESP RJ-45 Port

Clear To Send

N/C

N/C

Signal Ground

Transmit Data

Receive Data

Data Carrier Detect

N/C

Data Terminal Ready

Request to Send

1

..........

Pin #

10

9

8

7

6

5

2

1

4

3

Pin #

5

1

7

2

3

8

To Modem

Clear to Send

Signal Ground

Transmit Data

Receive Data

Data Carrier Detect

4

20

.

Data Terminal Ready

Request to Send ........ .

.....

DB-25 (MALE)

Cable End View

Figure 5. Cable Pin Assignments for ESP RJ-45 to Modem DB-25

5

Equinox ESP Multi-Interface Serial Hub Product Installation Guide

1.3 RS-232 Modular Adaptors and Cables

RS-232 modular adaptors are available from Equinox to convert RJ-45 modular jacks to DB-25 or DB-9 connectors. These modular adaptors, used with the 10-wire reversing modular cables, perform the same functions as shown in Figures 3 through 5. Figure 6 shows the RS-232 modular adaptors available from Equinox.

10

1

RJ-45 10-PIN

RTS

DTR

DCD

RD

TD

GND

CTS

5

4

1

10

9

7

6

DB-25 RS-232

2

7

5

4

20

8

3

RTS

DTR

DCD

RD

TD

GND

CTS

Connect to

Modems & Multiplexers:

210097 [DB-25 DTE Male]

210098 [DB-25 DTE Female]

10

1

RJ-45 10-PIN

RTS

DTR

DCD

RD

TD

GND

CTS

5

4

1

10

9

7

6

DB-25 RS-232

4

6

3

7

5

8

20

2

CTS

DCD

DTR

TD

RD

GND

RTS

DSR

Connect to

Terminals & Printers:

210099 [DB-25 DCE Male]

210100 [DB-25 DCE Female]

10

1

RJ-45 10-PIN

RTS

DTR

DCD

RD

TD

GND

CTS

5

4

1

10

9

7

6

DB-25 RS-232

3

5

8

1

2

7

4

RTS

DTR

DCD

RD

TD

GND

CTS

10

1

RJ-45 10-PIN

RTS

DTR

DCD

RD

TD

GND

CTS

5

4

1

10

9

7

6

DB-25 RS-232

7

6

2

5

4

3

8

1

CTS

DCD

DTR

TD

RD

GND

RTS

DSR

Connect to

Modems & Multiplexers:

210101 [DB-9 Male] 210102 [DB-9 Female]

Figure 6. RS-232 Modular Adaptors

Table 4 lists the modular cables that are available from Equinox to use with the modular adaptors shown in Figure 6.

Part No. Description

690252

690253

690254

10-foot 10-Wire Reversing Modular Cable

25-foot 10-Wire Reversing Modular Cable

75-foot 10-Wire Reversing Modular Cable

Table 4. Available Reversing Modular Cables

The adaptors and cables listed above may be used to attach devices to the

ESP RJ-45 ports.

If a customer-supplied modular cable is used, make sure the cable is

reversing. See Figure 7.

6

Equinox ESP Multi-Interface Serial Hub Product Installation Guide

1 0 - W I R E

RTS

DTR

DCD

RD

TD

GND

CTS

7

8

5

6

3

4

1

2

9

10

4

3

6

5

10

9

8

7

2

1 CTS

RTS

DTR

DCD

RD

TD

GND

E S P P o r t M o d u l a r A d a p t e r

Figure 7. 10-Wire RJ-45 Reversing Cable

1.4 RS-530 Modular Adaptors

An RS-530 modular adaptor is available from Equinox to convert an RJ-45 modualr jack to a male DB-25 connector. The RS-530 adaptor is designed to be used with standard CAT 5 cable.

Each port that uses the RS-530 adaptor should be configured as RS-422.

Figure 8 shows the RS-530 modular adaptor available from Equinox.

10

1

RJ-45 10-PIN

Tx -

Tx +

GND

Rx +

Rx -

7

8

2

3

9

DB-25 RS-530

14

2

7

3

16

TD - (B)

TD + (A)

GND

RD + (A)

RD - (B)

210103 [DB-25 Male]

Figure 8. RS-530 Modular Adaptor

7

Equinox ESP Multi-Interface Serial Hub Product Installation Guide

1.4 INIT and RESET Buttons

The INIT button can be used to remove configured information from an

ESP unit. The ESP stores nonvolatile data such as SNMP community name, system contact and IP address in FLASH. This information can be erased by pressing the INIT button.

NOTE: Pressing the INIT button will interrupt ESP operation and cause reinitialization to occur.

The FLASH erase is performed in two phases. The first phase erases the configuration database, which contains all nonvolatile data except the IP address. The second phase erases the IP address and effectively restores the ESP to factory default. This feature can be used to erase the FLASH when the ESP is being reinstalled elsewhere on your network.

When the INIT button is first pressed, the ONLINE LED will begin to blink to confirm that you have pressed the INIT button. Pressing and holding the button for five seconds erases the configuration database in the ESP FLASH. When the database has been erased, the ONLINE LED begins to flash rapidly. If you release the INIT button before the five second mark, no action is taken, and the ESP does not reinitialize.

If the button is pressed and held for an additional five seconds, the IP address is also erased.

If any portion of the FLASH is erased, the ESP will reboot itself when the INIT button is released.

The RESET button can be used to reset the ESP. Pushing this button will cause an immediate reboot.

8

Equinox ESP Multi-Interface Serial Hub Product Installation Guide

Section 2 - Driver Installation

This section contains instructions for installing the ESP driver from the

Equinox SuperSerial CD-ROM. The ESP is supported under Windows

2000, Windows NT 4.0, Windows NT 3.51, OpenServer 5.0.5a or higher,

UnixWare 7.0.1a or higher, Linux and AIX 4.3 and 5.1.

2.1 Windows 2000

To install the Windows 2000 ESP driver, you must first run SETUP.EXE from the Windows 2000 ESP driver diskette that is made using the

Equinox SuperSerial CD-ROM. SETUP.EXE will install the necessary

Device Manager files for the ESP. Insert the diskette into your A: drive, set your default drive to A: and run SETUP .

The Windows 2000 ESP driver is installed when you install the first ESP.

1. Navigate to Settings - Control Panel - Add/Remove New Hardware.

2. From the Add/Remove Hardware Wizard, select Add/troubleshoot a

device.

3. Windows 2000 will search for new Plug and Play hardware on your computer. ESP devices are network-attached and are not located by the

Add New Hardware Wizard. A list of devices that can be installed will be displayed. Select Add a new device.

4. From the Find New Hardware page, select No, I want to select the hardware from a list.

5. A list of hardware types will be displayed. Select Multi-port serial adapters.

6. Windows 2000 will ask you to select a device driver. Highlight

Equinox Systems Inc., select Equinox Ethernet Serial Provider / Have

Disk and point the Wizard to your A: drive.

7. From the Select a Device Driver page, again select Equinox Ethernet

Serial Provider.

8. The Wizard will locate an ESP on your server’s local subnet and display information about that ESP. If your ESP does not yet have an

IP address, you must enter the IP address, then click Next.

9. The Wizard will display the ESP conguration for nal verication. If the IP address you assigned is correct, click Next.

10. The Wizard will now copy les from the Windows 2000 ESP driver diskette. During this process, the Equinox ESP driver le is examined for a Microsoft digital signature. If the ESP driver is not signed, a warning message is displayed. To continue the installation, read the warning and then click Yes.

If you click No, the installation will terminate and the ESP will not be installed on your server.

9

Equinox ESP Multi-Interface Serial Hub Product Installation Guide

11. Once all les are copied, click Finish.

Your ESP is now installed. Windows 2000 will now install the ESP serial ports.

2.2 Windows NT 4.0

1. Navigate to Settings - Control Panel - Network to display the

Network Control Panel. Select the Services tab. Click Add to install the ESP driver for Windows NT 4.0.

2. The Control Panel will generate a list of standard Network Services.

The Equinox ESP Service is a new network service. Click the Have

Disk button.

3. The Control panel will ask you to enter the pathname for the disk that contains the ESP Service installation les.

a) If you are installing from diskette, enter the drive letter of the diskette drive.

b) If you are installing from the Equinox SuperSerial CD, enter the pathname D:\DRIVERS\ESP\NT , where D: is your CD-ROM drive letter.

c) If you have stored the driver on the NT system or on a network drive, enter the full pathname for the location of the Equinox

ESP Service.

4. The Control Panel will copy les from the specied path to the required NT system directories. Once the copy is complete and the driver is installed, the Control Panel will automatically start the

Equinox ESP Service. It will also start the ESP Installation Wizard and attempt to locate ESP units on all local subnets.

Using the Installation Wizard, you can:

• Discover and install ESP units on local or remote subnets

• Congure ESP units and assign COM port numbers

• Replace an ESP unit on a local or remote subnet

See the online help in the ESP Installation Wizard for more information about ESP Discovery and Installation.

2.3 Windows NT 3.51

1. From the Main Program Group, double-click Control Panel -

Network.

2. A list of currently installed services is displayed. At the end of the list is an entry named <Other>. Select this entry and click Continue.

3. Follow Steps 3 and 4 from Section 2.2.

10

Equinox ESP Multi-Interface Serial Hub Product Installation Guide

2.4 OpenServer

The following sections contain procedures for installing the ESP driver on an Open Server release 5.0.5a or higher system.

2.4.1 Installing Directly from CD-ROM

1. Mount the CD-ROM volume using the following command: mount -f ISO9660,filemode=444 <device> <mount_point>

For example, the following command mounts a CD-ROM on drive 1 to /mnt: mount -f ISO9660,filemode=444 /dev/cd1 /mnt

2. Install the driver using the “custom” utility with media image

VOL.000.000

.

3. When custom prompts for Media Device, select Media Images.

4. When custom prompts for Image Directory, specify:

/mnt/DRIVERS/ESP/SCO

5. Follow the instructions for custom contained in the le:

/mnt/DRIVERS/ESP/SCO/README.

2.4.2 Creating and Using OpenServer ESP Installation Diskettes on OpenServer

1. Be sure the mkdev cdrom command has been run.

2. Mount the CD-ROM volume using the following command: mount -f ISO9660,lower <device> <mount_point>

For example, the following command mounts a CD-ROM on drive 0 to /mnt: mount -f ISO9660,lower /dev/cd0 /mnt

3. Run the following commands: cd /mnt [or other mount point]

./makeunix.sh

4. Follow the on-screen instructions to build an installation diskette for

OpenServer ESP.

5. Once the OpenServer installation diskette is created, refer to the following le for detailed installation instructions:

/drivers/esp/sco/readme.txt

11

Equinox ESP Multi-Interface Serial Hub Product Installation Guide

2.4.3 Creating and Using OpenServer ESP Installation

Diskettes on DOS

1. Load the Equinox SuperSerial Software CD into your CD-ROM drive.

2. Set your default drive to the CD-ROM drive letter.

3. Run the command MAKEUNIX and select the appropriate Equinox product and operating system for which diskettes are needed.

4. Once the OpenServer installation diskette is created, refer to the following le for detailed installation instructions:

/drivers/esp/sco/readme.txt

2.4.4 Creating and Using OpenServer ESP Installation

Diskettes on Microsoft Windows

1. Load the Equinox SuperSerial Software CD into your CD-ROM drive.

• If you have autoplay enabled, the Equinox SuperSerial Software

Installation screen will appear.

• If you do not have autoplay enabled, set your default drive to

D: and run the command D:\SETUP, where D: is your CD-ROM drive letter.

2. Click UNIX on the Main Window.

3. Select the UNIX operating system for which you need drivers. Follow the on-screen instructions for creating an installation diskette.

4. Once the OpenServer installation diskette is created, refer to the following le for detailed installation instructions:

/drivers/esp/sco/readme.txt

12

Equinox ESP Multi-Interface Serial Hub Product Installation Guide

2.5 UnixWare

The following sections contain procedures for installing the ESP driver on a

UnixWare release 7.0.1a or higher system.

2.5.1 Creating and Using UnixWare ESP Installation Diskettes on UnixWare

1. Mount the CD-ROM volume using the following command: mount -f cdfs -0 fperm=0555,nmconv=c -r/dev/cdrom/ c0b0t110/mnt

2. Run the following commands: cd /mnt [or other mount point]

./makeunix.sh

3. Follow the on-screen instructions to build an installation diskette for

UnixWare ESP.

4. Once the UnixWare installation diskette is created, refer to the following

le for detailed installation instructions: /drivers/esp/unixware/readme.txt

2.5.2 Creating and Using UnixWare ESP Installation Diskettes on DOS

1. Load the Equinox SuperSerial Software CD into your CD-ROM drive.

2. Set your default drive to the CD-ROM drive letter.

3. Run the command MAKEUNIX and select the appropriate Equinox product and operating system for which diskettes are needed.

4. Once the UnixWare installation diskette is created, refer to the following

le for detailed installation instructions: /drivers/esp/unixware/readme.txt

2.5.3 Creating and Using UnixWare ESP Installation Diskettes on Microsoft Windows

1. Load the Equinox SuperSerial Software CD in your CD-ROM drive.

• If you have autoplay enabled, the Equinox SuperSerial Software

Installation screen will appear.

• If you do not have autoplay enabled, set your default drive to

D: and run the command D:\SETUP, where D: is your CD-ROM drive letter.

2. Click UNIX on the Main Window.

3. Select the UNIX operating system for which you need drivers. Follow the on-screen instructions for creating an installation diskette.

4. Once the UnixWare installation diskette is created, refer to the following

le for detailed installation instructions: /drivers/esp/unixware/readme.txt

13

Equinox ESP Multi-Interface Serial Hub Product Installation Guide

2.6 Linux

The following sections contain procedures for installing the ESP driver on a Linux system.

2.6.1 Creating and Using Linux ESP Installation Diskettes on

Linux

1. Mount the CD-ROM volume using the following command: mount -t iso9660<device> <mount_point>

For example, the following command mounts the rst CD-ROM in a typical environment: mount -t iso9660/dev/cdrom /mnt/cdrom

2. Run the following commands: cd /mnt/cdrom [or other mount point]

./makeunix.sh

3. Follow the on-screen instructions to build an installation diskette for

Linux ESP.

4. Once the Linux installation diskette is created, refer to the following

le for detailed instructions: /drivers/esp/linux/readme.txt

2.6.2 Creating and Using Linux ESP Installation Diskettes on

DOS

1. Load the Equinox SuperSerial Software CD into your CD-ROM drive.

2. Set your default drive to the CD-ROM drive letter.

3. Run the command MAKEUNIX and select the appropriate Equinox product and operating system for which diskettes are needed.

4. Once the Linux installation diskette is created, refer to the following

le for detailed instructions: /drivers/esp/linux/readme.txt

2.6.3 Creating and Using Linux ESP Installation Diskettes on

Microsoft Windows

1. Load the Equinox SuperSerial Software CD into your CD-ROM drive.

• If you have autoplay enabled, the Equinox SuperSerial Software

Installation screen will appear.

• If you do not have autoplay enabled, set your default drive to

D: and run the command D:\SETUP, where D: is your CD-ROM drive letter.

2. Click UNIX on the Main Window.

3. Select the UNIX operating system for which you need drivers. Follow the on-screen instructions for creating an installation diskette.

4. Once the Linux installation diskette is created, refer to the following

le for detailed instructions: /drivers/esp/linux/readme.txt

14

Equinox ESP Multi-Interface Serial Hub Product Installation Guide

2.7 AIX

The following sections contain procedures for installing the ESP driver on an AIX release 4.3 or 5.1 system.

2.7.1 Installing Directly from CD-ROM (AIX 5.1 only)

This procedure is valid only on AIX release 5.1 systems.

1. Mount the CD-ROM volume using the following command: mount -v cdrfs -o ro /dev/cd0/mnt

2. Change to the RPMS directory using the following command: cd /mnt/RPMS/AIX51

3. Install the RPM using the following command: rpm -ivh ./espx-3.06.aix.5.1.ppc.rpm

4. Discover and initialize the ESP units using the following command:

/etc/eqnx/espcfg

2.7.2 Creating and Using AIX ESP Installation Diskettes on AIX

1. Mount the CD-ROM volume using the following command: mount -v cdrfs -o ro /dev/cd0/mnt

2. Run the following commands: cd /mnt

./makeunix.sh

3. Once the AIX installation diskette is created, refer to the following les for detailed installation instructions:

/drivers/esp/aix43/readme.txt

/drivers/esp/aix51/readme.txt

2.7.3 Creating and Using AIX ESP Installation Diskettes on

DOS

1. Load the Equinox SuperSerial Software CD into your DOS CD-ROM drive.

2. Set your default drive to the DOS CD-ROM drive letter.

3. Run the command MAKEUNIX and select the appropriate Equinox product and operating system for which diskettes are needed.

4. Once the AIX installation diskette is created, refer to the following les for detailed installation instructions:

/drivers/esp/aix43/readme.txt

/drivers/esp/aix51/readme.txt

15

Equinox ESP Multi-Interface Serial Hub Product Installation Guide

2.7.4 Creating and Using AIX ESP Installation Diskettes on

Microsoft Windows

1. Load the Equinox SuperSerial Software CD.

• If you have autoplay enabled, the Equinox SuperSerial Software

Installation screen will appear.

• If you do not have autoplay enabled, set your default drive to

D: and run the command D:\SETUP, where D: is your CD-ROM drive letter.

2. Click UNIX on the Main Window.

3. Select the UNIX operating system for which you need drivers. Follow the on-screen instructions for creating an installation diskette.

4. Once the AIX installation diskette is created, refer to the following les for detailed installation instructions:

/drivers/esp/aix43/readme.txt

/drivers/esp/aix51/readme.txt

16

Equinox ESP Multi-Interface Serial Hub Product Installation Guide

Declaration of Conformity

Manufacturer’s Name: Equinox Systems Inc.

an Avocent Company

Manufacturer’s Address:

declares, that the products

Product Name:

Model Names:

Product Options:

One Equinox Way

Sunrise, Florida 33351-6709 USA

Ethernet Serial Provider

ESP-8 10/100, ESP-16 10/100, ESP-MI

All

Year of Manufacture: 2002-

conform to the following Product Specification:

Safety: IEC No. 60950 2nd Ed., A1, A2, A3, A4

UL 1950 3rd Ed., CAN/CSA-C22.2 No. 950

EMC:

Supplementary Information:

EN 55022 Class A

EN 610003-2, EN 610003-3

FCC Part 15 Class A

EN 55024: 1998

The products herewith comply with the requirements of the Low Voltage

Directive, 73/23/EEC and the EMC Directive 89/336/EEC, including amendments by the CE-marking Directive 93/68/EEC.

17

Equinox ESP Multi-Interface Serial Hub Product Installation Guide

© 2002 Equinox Systems Inc. All rights reserved. Reproduction without permission prohibited.

Equinox, SuperSerial and Avocent are registered trademarks or trademarks of Avocent Corporation. All other brands and product names are trademarks of their respective holders.

Equinox makes no representations or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Information is subject to change without notice and does not represent a commitment on the part of Equinox Systems

Inc.

Federal Communication Commission (FCC) Statement

WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void user’s authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.

These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.

This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in the residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Canada

This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference

Regulations of the Canadian Department of Communications.

Le présent appareil numérique n ´émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le

Ministère des Communications du Canada.

European Union

WARNING; This is a Class A product. In domestic environment, this product may cause radio interference in which case the user may be required to take adequate measures.

18

Equinox ESP Multi-Interface Serial Hub Product Installation Guide

Equinox Systems Inc.

One Equinox Way

Sunrise, Florida 33351-6709

(954) 746-9000

Fax: (954) 746-9101 ftp.equinox.com

www.equinox.com

[email protected]

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement