Bradley Smoker HN-400 Installation instructions

Add to my manuals
9 Pages

advertisement

Bradley Smoker HN-400 Installation instructions | Manualzz

Installation

Instructions

HN-400

Barrier-Free Column Shower

Table of Contents

Pre-Installation Information . . . . . . . . . . . . . . . .2

HN-200 Column Shower Components and Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . .2

Installation Instructions

Type A Column Shower . . . . . . . . . . . . . . . . . .3

Supplies from Below/Vent Off Line

Type B Column Shower Installation . . . . . . . .4

Supplies from Above/Vent Through Column

Type H Column Shower Installation . . . . . . . .5

Supplies from Below/Vent Through Column

Type O Column Shower Installation . . . . . . . .6

Supplies from Above/Vent Off Line

Optional Shroud Installation . . . . . . . . . . . . . . . .7

Cleaning Instructions . . . . . . . . . . . . . . . . . . . . .9

Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

IMPORTANT:

Before beginning installation, all supply, drain and waste piping to the shower must be completed according to the rough-ins received with the drain assembly.

Check the local codes and ordinances in your area for proper location and connection requirements. Conformity to local codes is the responsibility of the installer.

Read and save this installation manual, which contains maintenance and repair information, for future reference.

215-781; Rev. D; EN 03-310

© 2003 Bradley Corporation

Page 1 of 9 12-16-2003

P.O. Box 309, Menomonee Falls, WI 53052-0309

TEL: 1-800-BRADLEY FAX: (262) 251-5817 http://www.bradleycorp.com

2

Barrier-Free Column Shower

HN-400 Installation Instructions

Pre-Installation Information

Overview

The Bradley HN-400 Barrier-Free Column Shower features one station that is adapted for use by the handicapped. Valve and showerhead height for all wash stations, including the handicapped station, measures 42" (1067 mm).

Components

Material: Column showers are constructed of 16-gauge, type 304 stainless steel. The base flange is

14-gauge stainless steel. All exposed stainless steel parts are #4 finish. Exterior brass components are polished and chrome-plated.

Handicapped Station: The handicapped station includes a grab bar, diverter valve, hand-held shower with bracket, in-line backflow preventer, and quick disconnect (see shower components and dimensions shown below).

HN-400 Column Shower

Components and Dimensions

SUPPLY

ELBOW

169-941

GRAB BAR

S53-039

MOUNTING

POST

S70-078

SWIVEL

CONNECTOR

169-943

INLINE

BACKFLOW

PREVENTER

169-988

QUICK

DISCONNECT

169-937

HOSE

169-937

HOSE SPRAY

169-936

DIVERTER

S45-323

SOAP TRAY

126-005A

42"

(1067 mm)

TO FLOOR

48"

(1219 mm)

TO FLOOR

Supplies required for installation:

• Supply piping to column’s 3/4" type “L” copper tubing

• 2" NPT vent pipe (for type B and type H drains only)

• (5) 5/16" screws (for shroud slip ring installation)

12-16-2003 Bradley Corporation • 215-781 Rev. D; EN 03-310

Installation Instructions

Barrier-Free Column Shower

HN-400

Installation Instructions for Type A HN-400 Column Shower

Step 1: Install column shower components

NOTE: Flush supply lines before making connections.

1. Remove the five bolts that secure the disposable washer to the drain and lift the disposable washer off.

2. Bolt the column shower to the drain with the five bolts

(removed in procedure #1) and oval washers provided (see

Figure 1).

(5) 5/16"-18

HEX-HEAD

BOLTS

160-092

Step 2: Connect water supply

1. Remove the two 1/4"-20 screws from the access panel on the lower body of the column shower and lift the panel off.

2. Through the access opening, connect water supplies to the shower’s 3/4" copper tubing as shown in Figure 2 (piping supplied by installer).

3. Turn on water to the shower and test for leaks and adequate water flow.

Figure 1

4. Replace the access panel onto the shower with 1/4"-20 screws provided.

(5) WASHERS

142-034

NOTE: For column shower drains with a dome grate drain, install the two halves of the grate with the screws provided after the column installation is complete.

Figure 2

Supplies from Below/Vent Off Line

Bradley Corporation • 215-781 Rev. D; EN 03-310 12-16-2003 3

Barrier-Free Column Shower

HN-400 Installation Instructions

Installation Instructions for Type B HN-400 Column Shower

Step 1: Install column shower components

NOTE: Flush supply lines before making connections.

1. Remove the five bolts that secure the disposable washer to the drain and lift the washer off.

2. Loosen the screw(s) securing the shower cover and lift the cover off. DO NOT remove the screw(s)!

3. Insert a 2" NPT vent pipe (supplied by installer) into the shower.

NOTE: Make sure that vent pipe does not snag internal wiring or come in contact with electronic components.

4. Position the shower over the drain and screw the 2" NPT vent pipe into the vent connection (see Figure 4).

5. Bolt the shower to the drain with the five bolts (removed in procedure #1) and oval washers provided (see Figure 1).

(5) 5/16"-18

HEX-HEAD

BOLTS

160-092

(5) WASHERS

142-034

Step 2: Connect water supply

1. Drop the supplies to the top of the column shower.

2. Slide the column cover up the vent and supply piping.

Figure 3

NOTE: If you are installing a column shroud, slide the slip ring up the vent and supply piping first, and then slide the column cover up (see page 7 for shroud installation).

3. Make supply connections. Supply connection must be made inside the top of the shower so that there is no interference with the piping and the column cover.

4. Turn on water to the shower and test for leaks and adequate water flow.

5. Secure the column cover with the screws provided.

NOTE: For column shower drains with a dome grate drain, install the two halves of grate with the screws provided after column installation is complete.

4

Supplies from Above/Vent Through Column

12-16-2003

Figure 4

Bradley Corporation • 215-781 Rev. D; EN 03-310

Installation Instructions

Barrier-Free Column Shower

HN-400

Installation Instructions for Type H HN-400 Column Shower

Step 1: Install column shower components

NOTE: Flush supply lines before making connections.

1. Remove the five bolts that secure the disposable washer to the drain and lift the washer off.

2. Loosen the screw(s) securing the shower’s cover and lift the cover off. DO NOT remove the screw(s)!

3. Insert a 2" NPT vent pipe (supplied by installer) into the shower.

NOTE: Make sure that the vent pipe does not snag internal wiring or come in contact with the electronic components.

4. Position the shower over the drain and screw the 2" NPT vent pipe into the vent connection (see Figure 6).

5. Bolt the shower to the drain with the five bolts (removed in procedure #1) and oval washers provided (see Figure 5).

(5) 5/16"-18

HEX-HEAD

BOLTS

160-092

(5) WASHERS

142-034

Step 2: Connect water supply

1. Remove the two 1/4"-20 screws from access panel on lower body of column shower and lift panel off.

Figure 5

2. Through access opening, connect water supplies to the shower’s 3/4" copper tubing as shown in

Figure 6 (piping supplied by installer).

3. Slide column cover over vent.

NOTE: If you are installing a column shroud, slide the slip ring up the vent and supply piping first, and then slide column cover up (see page 7 for shroud installation).

4. Turn on water to the shower and test for leaks and adequate water flow.

5. Replace access panel onto shower with the 1/4"-20 screws provided.

NOTE: For column shower drains with a dome grate, install the two halves of grate with the screws provided after the column installation is complete.

Supplies from Below/Vent Through Column

Bradley Corporation • 215-781 Rev. D; EN 03-310 12-16-2003

Figure 6

5

Barrier-Free Column Shower

HN-400 Installation Instructions

Installation Instructions for Type O HN-400 Column Shower

Step 1: Install column shower components

NOTE: Flush supply lines before making connections.

1. Remove the five bolts that secure the disposable washer to the drain and lift the washer off.

2. Bolt the shower to the drain with the five bolts (removed in procedure #1) and oval washers provided (see Figure 7).

3. Loosen the screw(s) securing the shower’s cover and lift the cover off. DO NOT remove the screw(s)!

(5) 5/16"-18

HEX-HEAD

BOLTS

160-092

Step 2: Connect water supply

1. Drop the supplies to the top of the column shower.

2. Slide the column cover up the vent and supply piping.

NOTE: If you are installing a column shroud, slide the slip ring up the vent and supply piping first, and then slide the column cover up (see page 7 for shroud installation).

(5) WASHERS

142-034

Figure 7

3. Make the supply connections. The supply connection must be made inside the top of the shower so that there is no interference with the piping and the column cover.

4. Turn water to the shower on and test for leaks and adequate water flow.

5. Secure the column cover with the screws provided.

NOTE: For column shower drains with a dome grate, install the two halves of the grate with the screws provided after the column installation is complete.

6

Supplies from Above/Vent Off Line

12-16-2003

Figure 8

Bradley Corporation • 215-781 Rev. D; EN 03-310

Installation Instructions

Barrier-Free Column Shower

HN-400

Installation Instructions for Optional

Column Shower Shroud

NOTE: The column shower must be installed before the shroud. The shroud clips and knock-outs in the column cover must also be prepared. Before making the supply connections, slide the shroud slip ring up the vent and supply piping.

IMPORTANT: If the shroud is longer than 48"

(it has a welded seam rather than a snap together hem) it must also be slid up the vent and supply piping.

If the supply connections are completed prior to the shroud installation, the supplies will have to be disconnected in order to slide the slip ring (and shroud if over 48" long) over the vent and piping.

Step 3: Preparing the Column Cover

1. Remove the column cover from the top of the shower by loosening the screw(s) that secures the column cover retainer.

2. Carefully remove the necessary knock-outs from the cover (see Figure 11).

3. Insert the three shroud clips into the locations shown in Figure 11. Snap the clips in place using a flat blade screwdriver.

4. Reassemble the cover on shower and proceed with remainder of installation.

Step 4: Complete the Installation

1. Make sure the slip ring (and shroud if required) is in place over the vent and supply piping.

2. Fasten the slip ring to the ceiling with five 5/16" diameter screws (supplied by installer) (see

Figure 10 for screw location dimensions).

3. Bring the shroud seam around the vent and supply piping and slide the shroud together (0-48" long shrouds only). Fasten hem together using the supplied #6-32 screws.

4. With the column cover in place and the supply connections made, lower the shroud and fasten to the column cover with the #10-24 screws provided (see Figures 9 and 11).

SLIP RING

S57-020A (12" LONG)

S57-141 (7" LONG)

(SLIDES INSIDE SHROUD -

FASTEN TO CEILING WITH

5/16" SCREWS SUPPLIED

BY INSTALLER)

BOTTOM OF

SLIP RING

SHROUD

(0-48" LENGTHS

HAVE HEMMED EDGE)

(54"-72" LENGTHS

HAVE WELDED SEAM)

SCREW

160-400

Figure 9

Bradley Corporation • 215-781 Rev. D; EN 03-310 12-16-2003 7

Barrier-Free Column Shower

HN-400

Installation Instructions .....

continued

7-3/8" DIA

BOLT CIRCLE

Installation Instructions

(5) 3/8" DIA.

EQUALLY SPACED

HOLES

6-3/8" DIA

Figure 10

#10-24 x 1/2" SCREW

160-245 (QTY. 3)

Slip Ring Bolt Pattern

KNOCK-OUTS

SHROUD CLIP

159-413

(QTY. 3)

8

KNOCK-OUT

#10-24 x 3/4" SCREW

160-142

RETAINER-COLUMN COVER

132-049

Figure 11

COLUMN COVER

107-062A - 2-5 PERSON

107-074A - 6 PERSON

107-529 - 6 PERSON WITH THERMOBLENDER

107-530 - 2-5 PERSON WITH THERMOBLENDER

12-16-2003 Bradley Corporation • 215-781 Rev. D; EN 03-310

Installation Instructions

Barrier-Free Column Shower

HN-400

Cleaning Instructions

IMPORTANT: Cleanliness is of utmost importance. Do not permit salty solutions to evaporate and dry on stainless steel. Never use ordinary steel wool or steel brushes on stainless steel. Always use stainless steel wool or stainless steel brushes.

1. Remove ordinary deposits of dirt and grease with soap and water. Whenever possible, the metal should be thoroughly rinsed and dried after washing.

2. Use stainless steel polishing powder to get rid of tightly adhering deposits.

3. Look for the source of the rust in some iron or steel not actually a part of the stainless steel structure. Sometimes the appearance of rust streaks on stainless steel leads to the belief that the stainless steel is rusting. A steel nail or screw may be the cause of the trouble.

4. If the showerhead delivers an uneven spray, remove the showerhead from the unit, disassemble, and remove foreign matter.

5. Reassemble showerhead and reinstall into unit.

HN-400 Column Shower Warranty

Bradley Corporation warrants to commercial and institutional purchasers only each unit free from defects in material and workmanship under normal use and service upon the following terms and conditions:

1. This warranty is limited to replacing or repairing, at our option, transportation charges prepaid by the purchaser, any Bradley unit or part thereof which our inspection shall show to have been defective within the limitations of this warranty.

2. The period during which Column Shower components are warranted is one (1) year, measured from the date of our invoice.

3. This warranty does not cover installation or any other labor charges and does not apply to any units which have been damaged by accident, abuse, improper installation or improper maintenance.

4. The replacement or repair of defective units as stated in this warranty shall constitute the sole remedy of the purchaser and the sole liability of Bradley Corporation under this warranty. Bradley Corporation shall not otherwise be liable under any circumstances for incidental, consequential or indirect damages caused by defects in the repair or replacement thereof.

5. This warranty extends only to commercial and institutional purchasers and does not extend to any others, including consumer customers of commercial and institutional purchasers.

6. This warranty is in lieu of all other warranties, express or implied, including any implied warranty of merchantability or fitness for a particular purpose or otherwise.

Bradley Corporation • 215-781 Rev. D; EN 03-310 12-16-2003 9

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals