IMI CORNELIUS INC g

One Cornelius Place g

Anoka, MN 55303-6234

Telephone (800) 238-3600 Facsimile (612) 422-3246

INSTALLING REPLACEMENT AGITATOR MOTOR

KITS (P/N 569000207 AND P/N 569000208)

ON

VANTAGE DISPENSERS

IMPORTANT: Only qualified Personnel should install this kit.

Unpack and inspect the kit. Make sure all kit items are present and in good condition.

Table 1. Loose-Shipped Parts

Item

No.

Part No.

1 314072000

314150000

2 319828000

3 560001745

4 000268010

Agitator Motor Ass’y, 115 VAC (Kit P/N 569000207)

Agitator Motor Ass’y, 230 VAC (Kit P/N 569000208)

Screw, Thread Rolling, Phil Pn Hd; No. 10–24, .375 Long

Mounting Template

Drill Bit, 5/32

Name

REMOVING OLD AGITATOR MOTOR ASSEMBLY

WARNING: Disconnect electrical power from the Unit to prevent personal injury before attempting any internal maintenance. Only qualified personnel should service the internal components or electrical wiring.

Qty.

1

1

3

1

1

1. Disconnect electrical power from the Dispenser.

2. Remove hood from Dispenser, then remove cover from electrical control box (see Figure 1).

3. Disconnect old agitator motor assembly electrical wires from L

1

and L

2

terminals on the PC board (see

Figures 1 and 4) inside the electrical control box.

4. Remove old agitator motor assembly from refrigeration deck. Discard old motor and it’s mounting screws.

INSTALLING NEW AGITATOR MOTOR ASSEMBLY

1. Cut out “AGIT PORT CUT-OUT” area of the MOUNTING TEMPLATE (item 3) with a scissors as shown in

Figure 2. Remove adhesive covering from back side of the mounting template, then place template (align template holes with existing agitator motor mounting holes) over the existing agitator motor cut-out in the refrigeration deck.

2. Temporarily install the electrical control box cover to protect the PC boards from metal shavings while drilling. Center punch two hole locations indicated on the mounting template, then using DRILL BIT (item 4) drill indicated holes in the refrigeration deck.

E

IMI Cornelius Inc; 1997 May 20, 1997

560001744

3. Remove electrical control box cover. Remove mounting template from the refrigeration deck, then install new AGITATOR MOTOR ASSEMBLY (item 1) on the refrigeration deck (see Figure 3) and secure with two SCREWS (item 2).

4. Connect agitator motor assembly electrical wires to L

1

and L

2

terminals on the PC board inside the electrical control box as shown in Figure 4.

5. Install cover on the electrical control box. MAKE SURE AGITATOR MOTOR WIRES ENTERING

THE ELECTRICAL CONTROL BOX ARE NOT PINCHED.

6. Install hood on the Dispenser, then connect electrical power to the Dispenser. Check Dispenser for proper operation.

ELECTRICAL CONTROL

BOX COVER

OLD AGITATOR

MOTOR

P.C.

BOARDS

ITEM 3 o

AGIT. PORT

CUTOUT o

FRONT

AGITATOR MOTOR

MOUNTING TEMPLATE

MOUNTING TEMPLATE

(ITEM 3)

FIGURE 1.

APPLY TO

REFRIGERATION DECK

FIGURE 2.

ITEM 2

SLINGER

(DO NOT MOVE)

MOUNTING TEMPLATE

(ITEM 3)

AGIT. MTR.

LEADS

AGIT. MTR.

PUMP

B

JUMPER

RIBBED COMP

A

SERV CORD

COND. AREA

REFRIGERATION

DECK

FIGURE 3.

560001744 2

FIGURE 4.

advertisement