Calix E7-2 Installation manual

Add to My manuals
62 Pages

advertisement

Calix E7-2 Installation manual | Manualzz

Calix E7-2 Installation Guide

May 2013

#220-00320, Rev. 13

Contents

About This Guide...................................................................... 5

Chapter 1: Calix E7-2 Product Overview ............................... 7

Introducing the Calix E7-2 ........................................................................................ 8

Product Dimensions ................................................................................................ 10

Chapter 2: Installation Considerations ................................ 11

Installation Guidelines ............................................................................................ 12

Safety Recommendations and Notices.................................................................. 13

Required Items ......................................................................................................... 14

Preparations Before You Begin .............................................................................. 16

Chapter 3: Installing the Calix E7-2 ...................................... 17

Installing the E7-2 Chassis ..................................................................................... 18

Grounding the Chassis ........................................................................................... 21

Connecting DC Power ............................................................................................. 23

Installing the Fan Module........................................................................................ 24

Installing E7-2 Line Cards ....................................................................................... 26

Installing a Fiber Guide ........................................................................................... 28

Installing an Intake/Exhaust System ...................................................................... 31

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

4

Chapter 4: Wiring the E7-2 Network Interfaces ................... 33

Connecting the E7-2 Management Interfaces ....................................................... 34

Connecting to the Ethernet Management Ports .............................................. 34

Connecting to the RS-232 Serial Port ............................................................. 36

Wiring the External Alarm and Timing Interfaces ................................................. 37

Wiring External Alarms ................................................................................... 37

Wiring the BITS Timing Interface .................................................................... 39

Connecting the E7-2 Line Interfaces ...................................................................... 41

Installing Pluggable Transceiver Modules ....................................................... 42

Connecting Fibers ........................................................................................... 43

Connecting to the Copper Access Interfaces .................................................. 44

Chapter 5: Maintenance ........................................................ 47

Replacing Pluggable Transceiver Modules ........................................................... 48

Replacing an E7-2 Line Card .................................................................................. 49

Replacing the Fan Module ...................................................................................... 50

Fan Filter Maintenance ............................................................................................ 51

Chapter 6: Reference Information ........................................ 53

E7-2 Specifications .................................................................................................. 54

E7-2 LED Behavior .................................................................................................. 55

RS-232 Serial Port Pins ........................................................................................... 57

RJ-21 Pin Assignments ........................................................................................... 58

Fiber Handling Techniques ..................................................................................... 60

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

About This Guide

This document provides a general installation practice for the Calix E7-2 Ethernet service access platform. This document includes guidance for planning, power installation, cabling, and maintenance.

Intended Audience

This document is intended for use by network planning engineers, outside plant engineers,

CO technicians, and field support personnel, as well as craft personnel responsible for equipment installation, cabling, and maintenance. Familiarity with standard telecom and datacom terminology and practices, as well as standards-based Ethernet technologies and conventions, is recommended.

Related Documentation

You can access all Calix product documentation, including Calix E7-2 configuration practices, from the Calix Resource Center online at www.calix.com

( https://www.calix.com/portal/site/resourcecenter/).

Safety Notices

This document uses the following safety notice conventions.

DANGER! Danger indicates the presence of a hazard that will cause severe personal injury or death if not avoided.

WARNING! Warning indicates the presence of a hazard that can cause severe personal injury if not avoided.

CAUTION! Caution indicates the presence of a hazard that can cause minor to moderate personal injury if not avoided.

ALERT! Alert indicates the presence of a hazard that can cause damage to equipment or software, loss of data, or service interruption if not avoided.

5

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

6

DANGER! CLASS 1 LASER PRODUCT. INVISIBLE LASER RADIATION

MAY BE PRESENT. Fiber optic radiation can cause severe eye damage or blindness. Do not look into the open end of an optical fiber.

CE Marking Conformity

The Calix E7-2 product complies with the Council of European Communities

Directive 93/68/EEC. A copy of the

CE marking EC Declaration of

Conformity for the Calix E7-2 is available upon request. Contact your Calix

Sales Engineer for more information.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

Chapter 1

Calix E7-2 Product Overview

This chapter introduces the Calix E7-2 Ethernet service access platform and provides a general overview of the E7-2 small form factor chassis and components.

Topics Covered

This chapter covers the following topics:

Introducing the Calix E7-2

Product dimensions

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

8

Introducing the Calix E7-2

The Calix E7-2 Ethernet service access platform is a compact IP services networking system that provides high performance Ethernet-based transport, aggregation, and FTTP services delivery from an environmentally hardened, small form factor chassis.

Calix E7-2 system

The Calix E7-2 delivers a wide array of high performance applications, including 10GE

Ethernet transport, high-density residential triple play services over GPON and point-topoint Ethernet, Metro Ethernet Forum (MEF) compliant business services, mobile backhaul, and protected GE aggregation.

Calix E7-2 shelf views

The Calix E7-2 system consists of the 2-slot E7-2 chassis, a removable fan module, and up to two high capacity line cards in universal card slots.

Calix E7-2 (front)

The Calix E7-2 line cards and fan module install into the front of the E7-2 shelf. When equipped with line cards, the E7-2 front panel also terminates system line interfaces (fibers).

The E7-2 fan module is equipped with Craft Ethernet and serial ports for management and features several system status indicators.

Calix E7-2 (rear)

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

The E7-2 power inputs (A/B), ground, alarm I/O, Craft management, and BITS timing interfaces are located on the rear of the E7-2 shelf. The E7-2 rear panel also has four RJ-21 copper interface connectors.

9

Calix E7-2 cards

The Calix E7-2 is equipped with two universal line card slots, supporting a flexible array of high capacity line cards, including:

Fiber access service line cards: Calix E7-2 fiber cards provide optical ports for front access termination.

Copper access service line cards: Calix E7-2 copper cards (e.g., VDSL2) terminate on the E7-2 rear panel.

All E7-2 line cards use pluggable transceiver modules for optical and copper-based interfaces, including industry standard SFP, SFP+ and XFP modules. Each port on each card has an

LED to indicate an established link and data traffic activity. For detailed information on the

E7-2 line cards, see the Calix E7 User Guide.

An E7 'blank' card (equipped with no electronics) ships with every E7-2 shelf. The blank card plugs into either of the two universal slots and is used to maintain emissions and facilitate proper airflow in E7-2 systems with only one line card. Whenever an E7-2 shelf operates with only one line card, a blank card must be installed in the other slot.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

10

Product Dimensions

E7-2 chassis dimensions

The Calix E7-2 chassis exterior dimensions follow:

Height: 1.7 inches (4.3 cm)

Width: 17.5 inches (44.5 cm)

Depth: 11.45 inches (29.1 cm)

E7-2 fan module dimensions

The Calix E7-2 fan module exterior dimensions follow:

Height: 1.63 inches (4.1 cm)

Width: 2.67 inches (6.8 cm)

Depth: 10.82 inches (27.5 cm)

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

Chapter 2

Installation Considerations

This section discusses general installation considerations and guidelines. Review this information before starting the installation process.

Topics Covered

This section covers the following topics:

Installation guidelines

Safety recommendations and notices

Items required for installation (tools and materials)

Preparations before you begin

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

12

Installation Guidelines

Review the following guidelines before starting installation activities.

General guidelines

Follow these general guidelines and practices:

Read this document completely before starting any installation activities.

Only qualified, professional personnel should perform the procedures described in this document.

Follow standard safety precautions when performing installation and maintenance tasks.

Always wear standard safety gear when performing installation and maintenance tasks

(hardhats/safety headgear, reflective vest, eye protection, insulated gloves).

For safety, keep bystanders and other unauthorized personnel away from work operations at all times.

If the E7-2 is to be installed in an outdoor cabinet, do not perform installation activities during thunderstorms or when the threat of lightning is present.

The E7-2 installation kit includes power and ground cables that are 12 feet (3.66 m) in length. If you cannot locate the E7-2 within 12 feet (3.66 m) of the power/ground source, you must supply your own cables.

Calix offers a 3rd party DC distribution panel with dual power feed, 10+10 (A+B) GMT fuse positions (Calix part number 100-02234).

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

Safety Recommendations and Notices

13

WARNING! The intra-building port(s) of the equipment or subassembly is suitable for connection to intra-building or unexposed wiring or cabling only.

The intra-building port(s) of the equipment or subassembly MUST NOT be metallically connected to interfaces that connect to the Outside Plant (OSP) or its wiring. These interfaces are designed for use as intra-building interfaces only (Type 2 or Type 4 ports as described in GR-1089-CORE,

Issue 4) and require isolation from the exposed OSP cabling. The addition of Primary Protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring.

WARNING! This product should be protected by a surge protector that meets the applicable criteria of GR-974-CORE or GR-1361-CORE. Failure to utilize an appropriate surge protector could result in susceptibility to lightning surges or create a potential hazard due to power faults.

WARNING! Only qualified technical personnel should perform the procedures in this document. These procedures involve potentially hazardous activities that could cause injury to untrained personnel.

DANGER! Risk of high power current surge and electric shock. Read and understand all power procedures before performing tasks. Take necessary precautions and use appropriate insulated tools when working with power.

This equipment must be installed, operated, and serviced by qualified technical personnel only.

DANGER! CLASS 1 LASER PRODUCT. INVISIBLE LASER RADIATION

PRESENT. Fiber optic radiation can cause severe eye damage or blindness. Do not look into the open end of an optical fiber.

ESD ALERT! Beware of electrostatic discharge. Follow standard ESD precautions. Always wear a grounded ESD wristband to avoid damaging the electronic equipment.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

14

Required Items

Verify that the following items are on hand before you begin the installation.

Calix-supplied items

The Calix E7-2 installation package includes the following items:

Qty Description

1

1

1

4

8

4

1

1

1

4

4

Calix E7-2 two-slot chassis (1 RU)

Calix E7-2 fan module

Calix E7-2 blank line card

Rack mounting ears; 19-inches (48.26-cm) (2 ea.) and

23-inches (58.42-cm) (2 ea.)

Flathead Phillips screws, 4-40 x .1875 inches (.6 cm)

(for attaching mounting ears)

Self-tapping mounting screws, 12-24

(for rack mounting)

Power cable, A/B inputs;18 AWG, 12 ft (3.66 m)

Ground cable; 8 AWG, 12 ft (3.66 m), plus termination hardware (2 ea. washers, nuts)

Spare 2-hole ground lug (8 AWG)

Cable tie mounts

(for RJ-21 connector using a 90 degree exit)

Panhead Phillips screws, 4-40 x .25 inches (.6 cm)

(for securing cable tie mounts to RJ-21 connectors that use a 90 degree exit)

The following optional equipment is ordered and packaged separately, as required:

Pluggable transceiver modules (required for line termination)

Fiber guide suitable for all E7-2 deployments, including ETSI racks

Cool air intake and rear heat exhaust system to redirect airflow to the rear of the chassis

RS-232 console cable (DB-9F to RJ-11M) to connect to a PC for console management

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

User-supplied items

The following user-supplied tools and materials are required for installation.

Power drill with universal sockets and screwdriver bits

Socket wrench/nut driver set (standard)

Screwdriver set (standard)

Cable ties (tie-wraps)

Wire stripper

Compression crimping tool

Digital multi-meter

Fiber splicer

Fiber jumpers (LC for Ethernet interfaces; SC/UPC for GPON interfaces)

Fiber management system (distribution, ducts, raceways, etc.)

15

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

16

Preparations Before You Begin

Complete the following preparations before you begin the installation process.

Site requirements

Before starting the installation, verify that the following conditions are true:

All materials are onsite and inventoried.

An equipment rack and grounding system are available

Minimum clearances are met for each device.

Access to a -48 VDC power source with fuse-protected distribution is available.

The installation site has restricted access.

Cable lengths and wire gauges are adequate for the services provided.

Thermal budget is accounted for and approved.

Assignments for power, transport, services, alarms, timing, and other interfaces have been defined.

Determining an installation location

For indoor rack-mounted units, keep the following requirements in mind when choosing an installation location:

As an environmentally hardened system, the Calix E7-2 is suitable for installation in network telecommunication facilities including outside plant (OSP) locations.

The E7-2 requires one rack unit (1 RU) of mounting space on a standard 19- or 23-inch

(48.26- or 58.42-cm) equipment rack.

The E7-2 fan module is located on the right side of the unit. The system requires adequate airflow space on the right side (intake) and left side (exhaust) of the unit for proper cooling. For this reason, EIA or 23-inch (58.42-cm) racks are preferred over 19inch (48.26-cm) telco racks.

Note: Calix offers an optional cool air intake and rear heat exhaust system to assure adequate airflow. Refer to

Installing an Intake/Exhaust System (on page 31 ) for installation

instructions.

Locate the E7-2 near power supply and ground termination locations.

Note: The power and ground cables supplied with the E7-2 installation kit are 12 feet

(3.66 meters) long.

Power, ground, and alarm wiring at the rear of the E7-2 must be properly secured with strain relief.

Fibers attached to pluggable transceiver modules on the front of the E7-2 unit must be appropriately dressed and secured with strain relief to avoid exceeding the manufacturer's bend radius standards.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

17

Chapter 3

Installing the Calix E7-2

This section describes how to install the Calix E7-2 chassis and components onto a standard equipment rack.

Topics Covered

This section covers the following topics:

Installing the E7-2 chassis

Grounding the E7-2 chassis

Connecting DC power to the E7-2 chassis

Installing the E7-2 fan module

Installing E7-2 line cards

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

18

Installing the E7-2 Chassis

This topic describes how to install the E7-2 chassis into an equipment rack.

Calix offers the following rack mount options:

E7-2 vertical mounting kits for vertical chassis orientation in 19- or 23-inch racks

E7-2 ETSI rack mounting kit to provide a 75 mm forward offset limitation from the rack mounting rail

To install the E7-2 chassis

1.

Get a pair of mounting ears and (8) flat head screws from the installation kit.

Note: The kit includes two sets of mounting ears, one pair for 19-inch (48.26-cm) racks and another for 23-inch (58.42-cm) racks.

2.

Attach (2) mounting ears to the E7-2 chassis using supplied hardware. You can install the ears in a flush-mount or projection-mount position as required.

3.

Mount the E7-2 chassis onto the equipment rack: a. Identify the E7-2 mounting location on the rack. b. Position the E7-2 chassis against the rack at the identified location, aligning its ear holes with the counterpart holes on the rack. c. Install (4) mounting screws to secure the unit in place.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

To install an E7-2 vertical mounting frame

19

1.

Identify the exact mounting location on the equipment rack for the E7-2 mounting frame. The frame requires approximately 22 inches (55.88 cm) of vertical rack space.

2.

Install the mounting frame's top bracket as follows: a. Orient the bracket with its equipment-mounting flange on the top. b. Position the bracket against the rack at the identified location, aligning the bracket's mounting holes with counterpart holes on the rack. c. Attach the top bracket to the rack using (4) supplied mounting screws (2 per side).

3.

Install the mounting frame's bottom bracket as follows: a. Orient the bracket with its equipment-mounting flange on the bottom. b. Position the bottom bracket against the rack 19 inches (48.26 cm) below the top bracket, aligning the bracket's mounting holes with counterpart holes on the rack. c. Attach the bottom bracket to the rack using (4) supplied mounting screws (2 per side).

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

20

4.

Install the heat deflector above or below the mounting frame (typically above) as follows: a. Orient the deflector with the baffle directly above the mounting frame's top bracket. b. Position the deflector against the rack at the identified location, aligning the deflector's mounting holes with counterpart holes on the rack. c. Attach the deflector to the rack using (4) supplied mounting screws (2 per side).

After the vertical mounting frame is installed, you can install Calix E7-2 units onto the frame as required. Mount the E7-2 chassis with its right side (fan tray) on the bottom, to direct airflow upward.

To install an E7-2 with the ETSI rack mounting kit

1.

Get the pair of ETSI rack mounting ears from the installation kit.

2.

Attach each mounting ear to the E7-2 chassis as follows: a. Position the bracket against the side of the chassis, aligning the bracket's (4) equipment mounting holes with the counterpart holes on the chassis. b. Attach the mounting ear to the E7-2 chassis using (4) supplied flat head screws.

3.

Mount the E7-2 chassis onto the equipment rack: a. Identify the E7-2 mounting location on the rack. b. Position the E7-2 chassis against the rack at the identified location, aligning its ear holes with the counterpart holes on the rack. c. Install (4) mounting screws to secure the unit in place.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

Grounding the Chassis

21

The Calix E7-2 ground system can be connected to a Common Bonding Network (CBN) or

Isolated Bonding Network (IBN).

Note: For environments that employ an IBN scheme, the low voltage and frame grounds on the E7-2 shelf are isolated from the input power DC-return.

The installation kit includes a 12-foot (3.66-meter) ground cable, plus hardware to attach it to the E7-2 frame ground.

ESD ALERT! Beware of electrostatic discharge. Follow standard ESD precautions. Always wear a grounded ESD wristband to avoid damaging the electronic equipment.

To ground the E7-2 chassis

1.

Get the ground cable and supplied hardware (pair of 10-32 Keps nuts and washers) from the installation kit.

Note: The Calix-supplied ground cable uses UL-listed ground compression lugs (p/n

615-0001). If you use a ground cable other than the one supplied by Calix, be sure to coat the bare conductor with an appropriate antioxidant compound before making any crimp connections

2.

Connect the ground cable to the E7-2 chassis as follows: a. Install (2) star washers and then the ground cable's 2-hole lug onto the dual-post

Frame Ground terminal (located on the rear of the chassis). b. Install (2) 10-32 Keps nuts onto the Frame Ground posts to secure the lug in place.

Tighten to 27 in-lbs. of torque.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

22

3.

Connect the chassis ground cable to the main ground system (preferred) or to the rack frame as follows: a. Route the ground cable to the grounding termination location. If the cable is too long, cut the cable to length and crimp on an appropriate lug. (A spare lug is included in the installation kit.) b. Connect the ground cable to the main ground system or rack frame per PANI guidelines.

Note: Grounding surfaces must be brought to a bright finish and coated with antioxidant before being joined. When grounding to a rack frame, ensure that there is no paint or debris between the ground lug and the rack frame. To ensure a reliable ground bond, apply an anti-oxidant and use paint piercing star washers and thread forming screws to secure a metal-to-metal ground contact to the rack frame.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

Connecting DC Power

23

The Calix E7-2 requires -48 VDC input power. The installation kit includes a 12-foot (3.66meter) DC power cable with A and B leads.

Note: The E7-2 must be installed in an Isolated DC return (DC-I) configuration, where the

DC return is not connected to the grounding system.

DANGER! Risk of electric shock. Only a qualified technician should perform this procedure

To connect DC power to the E7-2

1.

Get the DC power cable from the installation kit.

2.

On E7-2 rear panel, loosen the captive thumbscrew securing the clear plastic power terminal cover to the chassis, and then remove the cover.

3.

Connect the DC power cable to the E7-2 chassis as follows: a. Connect to the A-side power input:

Connect the black (A) RTN wire to the (A) + RTN terminal.

Connect the red (A) BATT wire to the (A) - BATT terminal. b. Connect to the B-side power input:

Connect the black (B) RTN wire to the (B) + RTN terminal.

Connect the red (B) BATT wire to the (B) - BATT terminal. c. Tighten the power termination screws to 9 in-lbs.

4.

Replace the terminal cover and tighten the thumbscrew. Make sure all wires exit cleanly to the left.

5.

Route the power cable to the local DC power source and connect it per local practice.

Note: Use 7.5 Amp GMT fuses to protect the E7-2 DC distribution circuits.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

24

Installing the Fan Module

Install the E7-2 fan module into the E7-2 shelf as described below.

Calix offers two fan module types—FTA and FTA2 (as indicated on the fan module faceplate). FTA supports two fan speeds. FTA2 supports four fan speeds with E7 release 2.2 or higher; in releases prior to 2.2, FTA2 supports two fan speeds.

Note: The E7-2 fan module includes an air filter for use in indoor/office environments only.

Do not use the air filter for outdoor/cabinet deployments, to provide maximum airflow to the E7-2.

To install the E7-2 fan module

1.

Unpack the E7-2 fan module from its packaging.

2.

For indoor deployments only, insert the air filter into the fan module. (The filter resides on the right edge of FTA2 or on left edge of the FTA, against the fans.)

Note: FTA2 is shown below. For the FTA, proper orientation of the air filter requires the frame side to face the fans, and the rough side to face away from the fans.

ALERT! For the FTA model, improper orientation of the air filter will interfere with fan operation. Make sure the filter element’s rough side faces the left edge of the module, away from the fans.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

3.

Insert the fan module into the housing on the right side of the E7-2 chassis.

25

4.

Push the fan module all the way back into the slot. The unit seats once the latch clicks into place.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

26

Installing E7-2 Line Cards

The Calix E7-2 shelf is equipped with two universal line card slots. Install E7-2 line cards as described below.

Note: The E7-2 shelf ships with a 'Blank' card (no circuitry) installed in Slot 2. For applications using only one E7-2 line card, the Blank card must occupy the second slot.

Remove the Blank card for applications using two E7-2 line cards.

ESD ALERT! Beware of electrostatic discharge. Follow standard ESD precautions. Always wear a grounded ESD wristband to avoid damaging the electronic equipment.

Note: Some E7 line cards, such as the VDSL2 Overlay card, occupy two slots in the E7-2 shelf. Adjust the card installation procedure below as needed to install a "double wide" card into both E7-2 card slots simultaneously.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

27

To install an E7-2 line card

1.

Unpack the E7-2 line card from its packaging.

2.

Install the E7-2 line card into a vacant universal slot as follows: a. On the card faceplate, pull the ejector lever into the open (unlocked) position. b. Orient the card horizontally, with the ejector lever on the right side.

ALERT! To avoid damaging the card or shelf, align the card correctly with the guide rails in the slot before inserting the card. c. Insert the card into a vacant E7-2 card slot:

Slot 1 (bottom)

Slot 2 (top) d. Push the card ejector lever into the closed (locked) position to fully seat the card.

3.

Repeat the steps above to install a second line card into the E7-2 shelf, as required.

Otherwise, install the Blank card into the vacant slot.

Note: Due to airflow control considerations, the E7-2 shelf should not be operated with a vacant slot. If you are using only a single E7-2 line card at this time, install the Blank card into the other slot.

To install pluggable transceiver modules and to connect fibers, see

Connecting the E7-2 Line

Interfaces (on page 41 ).

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

28

Installing a Fiber Guide

The E7-2 chassis supports a field installed fiber guide option suitable for all E7-2 deployments, including:

Flush mounts, horizontal or vertical

Mid-mounts, horizontal or vertical

ETSI rack mount kit installations (See

Installing the E7-2 Chassis (on page 18 ) for

instructions on installing the ETSI rack mount kit.)

The fiber guide installation kit includes mounting brackets for flush and mid-mount deployments, and a 1RU fiber guide assembly.

After installing the E7-2 chassis, install the fiber guide as described below. Alternatively, for flush and mid-mounts you can install the fiber guide while installing the E7-2 chassis.

To install the fiber guide for E7-2 flush mounts (horizontal or vertical)

Note: This procedure applies to any 19- or 23-inch rack.

1.

Unpack the fiber guide kit, and locate the rack mounting bracket.

2.

Install the rack mounting bracket as follows: a. On the left rack rail or top vertical mounting frame, remove the (2) mounting screws securing the E7-2 chassis to the rack or frame and hold the chassis in place. b. Align the bracket's rack mounting holes with the same holes used to mount the E7-2 chassis. c. Secure the bracket and E7-2 to the rack or frame using the mounting screws removed in step 2a.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

3.

Attach the fiber guide assembly to the bracket using the bracket's two captive screws.

29

To install the fiber guide for E7-2 mid-mounts (horizontal or vertical)

Note: This procedure applies to any 19- or 23-inch rack.

1.

Unpack the fiber guide kit, and locate the mid-mounting bracket.

2.

On the left side of the E7-2 chassis (oriented horizontally or vertically), align one set of the bracket's captive screws with the forward mounting holes on chassis, and tighten the screws to secure the bracket to the chassis.

3.

Attach the fiber guide assembly to the bracket using the bracket's remaining set of captive screws.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

30

To install the fiber guide for an E7-2 mounted with an ETSI rack mount kit

1.

Unpack the fiber guide assembly from its packaging.

2.

Orient the fiber guide with the fiber management on the left outside.

3.

Position the fiber guide's flat mounting plate against the right side of the installed ETSI mounting ear, aligning:

 the threaded fasteners on the fiber guide with the clearance holes on the ETSI mounting ear,

and

 the equipment mounting holes on the fiber guide with the counterpart holes on the

ETSI mounting ear.

4.

Attach the fiber guide assembly to the ETSI mounting ear using the (2) supplied SEMS screws.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

Installing an Intake/Exhaust System

The E7-2 chassis supports an optional field installed front cool air intake and rear heat exhaust system. The intake/exhaust system assures adequate airflow by redirecting airflow from the front of the chassis to the rear. Prior to installing the E7-2 chassis, mount the intake/exhaust system on the unit as described below.

Note: The intake/exhaust system converts the E7-2 into a 23-inch shelf.

31

To install an intake/exhaust system

1.

Unpack the intake/exhaust kit from its packaging.

2.

Orient the left rear exhaust plenum on the left side of the E7-2 chassis with the vent in the back, aligning the plenum's inner mounting holes with the counterpart holes on the chassis.

Note: The right and left plenums are not interchangeable.

3.

Attach the plenum to the E7-2 chassis as follows: a. Route a phillips screw driver through the access hole, and then through the chamber to the captive screw, and tighten the screw. b. Repeat step 3a to tighten the (5) remaining captive screws, securing the plenum in place.

4.

Orient the right front intake plenum on the right side of the E7-2 chassis with the vent in the front, aligning the plenum's mounting holes with the counterpart holes on the chassis.

5.

Repeat steps 3a–3b to attach the right front intake plenum to the E7-2 chassis.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

32

6.

Install a rack mounting ear to each plenum as follows: a. Position a mounting ear against the plenum, aligning its mounting holes with the counterpart holes on the plenum. b. Attach the mounting ear to the plenum using (4) supplied flathead screws.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

Chapter 4

Wiring the E7-2 Network Interfaces

This section describes how to wire out the Calix E7-2 network interfaces, including management, alarms, and service line interfaces.

Topics Covered

This section covers the following topics:

Connecting the E7-2 management interfaces

Wiring the E7-2 alarm and timing interfaces

Connecting the E7-2 line interfaces

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

34

Connecting the E7-2 Management Interfaces

This section describes how to connect to the E7-2 management interface ports, including front and rear Ethernet management ports and RS-232 serial port.

Connecting to the Ethernet Management Ports

The Calix E7-2 is equipped with two out-of-band 10/100 Ethernet management ports (RJ-45 connectors). The front Ethernet management port is located on the E7-2 fan module

(labeled MGT-1). The rear Ethernet management port is located on the E7-2 rear panel

(labeled MGMT-3).

Use the front Ethernet port for (temporary) local Craft access to the E7-2. If you require a permanent out-of-band management connection to the E7-2, Calix recommends using the rear Ethernet management port to connect to the LAN.

Note: Use a standard 'straight-through' Ethernet patch cable to connect to the E7-2

Ethernet management ports.

Note: When you connect a disabled MGT port on the E7 to an Ethernet switch, the link status lights on the switch light up (yellow, and then green after 30 seconds). A link is established between the E7 and the switch, but the Management interface on the E7 is not enabled and no traffic will pass over the link.

To connect to the front Ethernet management port

1.

Get a 'straight-through' Ethernet patch cable with RJ-45 connectors on both ends.

2.

Connect the cable to the E7-2 front Ethernet management port (labeled MGT-1, located on the E7-2 fan module).

3.

Connect the cable's other end to the Ethernet port on your PC.

For instructions to log in to the E7-2 management interface, refer to the

Calix E7-2 User

Guide.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

Use the rear Ethernet management port to establish a fixed out-of-band management connection to the E7-2.

To connect to the rear Ethernet management port

1.

Get an Ethernet patch cable with RJ-45 connectors on both ends.

2.

Connect the cable to the E7-2 rear Ethernet management port (labeled MGMT-3, located on the E7-2 rear panel).

35

3.

Connect the cable's other end to a LAN Ethernet hub or switch.

For instructions to log in to the E7-2 management interface, refer to the Calix E7 User Guide.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

36

Connecting to the RS-232 Serial Port

The E7-2 has an RS-232 serial port that you can connect to a PC for console management connections. The serial port is located on the E7-2 fan module (RJ-11F connector).

Note: Calix provides an optional RS-232 console cable, or you may supply your own cable with an RJ-11 male connector on one end and a DB-9 female connector on the other end.

See

RS-232 Serial Port Pins (on page 57 ) for more information.

To connect to the RS-232 serial port

1.

Get an appropriate RS-232 console cable (DB-9F to RJ-11M) to connect to the E7-2.

2.

Connect the cable's RJ-11 end to the E7-2 serial port (labeled

MGT-4, located on the

E7-2 fan module).

3.

Connect the cable's DB-9 end to your PC.

Use the following settings to establish a console connection from the serial port:

Baud Rate - 38400

Parity - None

Stop Bits - 1

Data Bits - 8

Flow Control - None

For instructions to log in to the E7-2 management interface, refer to the Calix E7 User Guide.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

Wiring the External Alarm and Timing Interfaces

37

This section describes how to wire external alarms and external (BITS) timing interfaces to the Calix E7-2. The E7-2 terminates its alarm and timing interfaces via wire-wrap pins located on the E7-2 rear panel.

Wiring External Alarms

The E7-2 supports eight external alarm input/output (I/O) positions via wire wrap pins located on the E7-2 rear panel. The eight external alarm positions include seven inputs and one output position.

Output Input

OUT+ AL1+ AL2+ AL3+ AL4+ AL5+ AL6+ AL7+

OUT- AL1- AL2- AL3- AL4- AL5- AL6- AL7-

Alarm Inputs (AL1 to AL7): You can configure the E7-2 alarm input positions to interface with up to (7) external input sources, typically for environmental alarm conditions. The input alarm contacts are Normally Open (default), and close when an alarm condition occurs. You can configure the alarm type and severity for each input from the E7-2 user interfaces.

Alarm Output (OUT): You can configure the E7-2 alarm output position to interface with external office alarm systems such as lights or horns. The output alarm contacts are Normally

Open (default).

Wire the E7-2 external alarm input/output (I/O) positions as described below. Typically, alarm wiring consists of black and white wire pairs.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

38

To wire external alarms

1.

Get up to eight 24 AWG wire pairs of sufficient length to reach the far-end contacts from the E7-2.

2.

At the E7-2 end, strip approximately one inch (2.54 cm) of insulation from the alarm wire ends.

3.

Wire the E7-2 alarm inputs as follows: a. Connect a pair of alarm wires to the first input position ( AL1):

Wrap the first wire (typically black) to the AL1+ pin.

Wrap the second wire (typically white) to the AL1- pin. b. Repeat Step 3a for each additional alarm input to use ( AL2AL7), as required.

4.

Wire the E7-2 alarm output position (

OUT) as follows:

Wrap the first wire (typically black) to the

OUT+ pin.

Wrap the second wire (typically white) to the OUT- pin.

5.

Route and dress the alarm wires out to the appropriate far-end interfaces and connect per local practice.

Refer to the Calix E7 User Guide for supported environmental alarms and alarm provisioning information.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

Wiring the BITS Timing Interface

39

The E7-2 supports synchronization with an external clock source via timing inputs located on the E7-2 rear panel. The E7-2 accepts a standard DSX-level timing source (DS1/T1 format only, not 64 kbps composite clock format) and should be set to ESF/B8ZS. Wire the

E7-2 timing inputs to a Building Integrated Timing System (BITS) clock source using shielded cable.

Calix recommends providing traceable clock synchronization for E7-2 GPON applications.

IN (A) SHLD TIP+ RNG-

IN (B) SHLD TIP+ RNG-

TIP+ RNG- TIP+ RNG-

OUT (A) OUT (B)

You can link up to ten collocated E7-2 shelves to share a BITS timing input. Calix offers a connectorized daisy-chain BITS cable, or you can wire-wrap the individual daisy-chain links between shelves.

To wire the BITS timing input interface

1.

Get up to two 24 AWG shielded 2-wire cables of sufficient length to reach the local

BITS clock interface from the E7-2. Use one cable to provide a single timing input (A only), or two cables for a redundant input (A + B).

2.

Strip approximately one inch (2.54 cm) of insulation from the wire ends.

3.

Wire the E7-2 external timing input(s) as follows: a. Connect the timing wires to the E7-2 BITS

IN (A) input position:

Wrap the positive (tip) wire to the

TIP+ pin.

Wrap the negative (ring) wire to the

RNG- pin.

Wrap the cable shielding to the SHLD pin. b. To provide a redundant connection to the BITS clock source, repeat Step 3a to wire the E7-2 BITS IN (B) input position, as required.

4.

Route and dress the timing input cable to the local BITS clock interface and connect per local practice.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

40

To provide timing relays to one or more additional collocated E7-2 units, you can wire the

E7-2 external timing output interface as described below.

To wire the BITS timing output interface

1.

Get up to two 24 AWG shielded 2-wire cables of sufficient length to reach the next E7-2 shelf. Use one cable to provide a single link (A only), or two cables for a redundant link

(A + B).

Note: You can use the optional Calix-supplied BITS daisy-chain cable instead. See the note after Step 4 for installation instructions.

2.

Strip approximately one inch (2.54 cm) of insulation from the wire ends.

3.

Wire the E7-2 external timing output as follows: a. Connect the timing wires to the E7-2 BITS OUT (A) output position:

Wrap the positive (tip) wire to the TIP+ pin.

Wrap the negative (ring) wire to the RNG- pin. b. To provide a redundant timing link to the next E7-2, repeat Step 3a to wire the E7-2

BITS OUT (B) position, as required.

4.

Route and dress the timing output cable to next E7-2 and connect per the input wiring procedure above.

Note: If you are using the Calix-supplied BITS daisy-chain cable, connect the WW Pins

Out end to the BITS OUT pins on the upstream E7-2 unit, and connect the WW Pins

In end to the BITS IN pins on downstream unit. Repeat for each additional daisychained E7-2 unit.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

Connecting the E7-2 Line Interfaces

This section describes how to connect the Calix E7-2 line interfaces to the network.

41

Equipping the E7-2 interface ports

Calix E7-2 line cards use pluggable transceiver modules to provide interface connections, but the cards do not ship equipped with modules. You must install pluggable modules into the cards to equip the ports.

Calix offers a full suite of optical and copper pluggable modules to support a wide array of applications. The E7-2 10GE and GPON ports require only Calix-supplied modules, but E7-

2 GE ports can use SFP modules from Calix or other suppliers, with some restrictions. Refer to the Calix E7-2 Product Planning Guide for complete details.

Note: When using SFP modules not supplied by Calix, you must use modules that comply with the SFP Transceiver MultiSource Agreement (MSA). See the Small Form Factor (SFF) committee INF-8074i specification Rev 1.0 for details.

Pluggable modules are available to support different facility types and connectors:

Port

Type

Module

Type

Interface Options

10GE

GE

GPON

XFP

SFP+

SFP*

OIM

10GE (10 Gbps) optical

10GE (10 Gbps) optical

10GE (10 Gbps) copper

GE (1000 Mbps) dual-fiber and single-fiber modules

FE (100 Mbps) dual-fiber and single-fiber modules

1000/100BaseT copper modules

2.4/1.2 Gbps PON optical

*All SFPs must be Class 1 laser devices in accordance with FDA regulation 21CFR 1040.10, 1040.11, and IEC 60825-1.

Note: For E7-2 deployments in outdoor/remote environments, be sure to use Industrialrated (i-temp) modules.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

42

Installing Pluggable Transceiver Modules

Install pluggable transceiver modules into the E7-2 line cards to equip the ports for optical or copper interface connections.

To install pluggable transceiver modules

1.

Unpack the pluggable module. Remove the dust cover from the transceiver interface, if present.

2.

Orient the module with the exposed PCB side facing down. Insert the module into an appropriate socket on an E7-2 line card as follows:

To equip 10GE ports: a. Insert XFP modules into sockets labeled XFP 1 or XFP 2, as required. b. Insert SFP+ modules into sockets labeled

SFP+ 1 or SFP+ 2, as required.

To equip GE ports, insert SFP modules into sockets labeled SFP 1 to SFP 12, as required.

To equip GPON OLT ports, insert GPON OIM modules into sockets labeled

GPON 1 to GPON 4, as required.

3.

Press the module firmly into the socket until it clicks into place.

Once the module is installed, you can connect interface cables (fibers) to it. See

Connecting

Fibers (on page 43 ) for instructions.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

Connecting Fibers

43

Once the E7-2 line card sockets are equipped with pluggable transceiver modules, you can connect fibers/cables to the ports as described below. Be sure the fiber connector type matches the connector type of the module(s). Use LC connectors for Ethernet interfaces and

SC/UPC connectors for GPON interfaces.

If the laser at the far end of the fibers is enabled, you can use an optical power meter to test signal strength before connecting fibers to the equipment. Defer to local practice wherever applicable.

DANGER! CLASS 1 LASER PRODUCT. INVISIBLE LASER RADIATION

MAY BE PRESENT. Fiber optic radiation can cause severe eye damage or blindness. Do not look into the open end of an optical fiber.

To connect fibers to the E7-2

1.

Route fibers (or copper Ethernet cables) to the E7-2 shelf, approaching from left side.

Important: Route fibers to the left side of the E7-2 shelf to ensure visibility of system and card status LEDs located on the right side of the E7-2 shelf.

2.

Remove the caps or plugs from the fiber connector ends, if present.

3.

Connect fibers to transceiver modules on the E7-2 line card.

4.

Repeat the steps above to connect additional fiber links, as required.

5.

Neatly dress and secure all fibers/cables per local practice.

Note: To avoid pinching or interference with the equipment, neatly coil or bundle any slack fiber and dress it toward the left side of the E7-2 shelf.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

44

Connecting to the Copper Access Interfaces

To terminate subscriber line interfaces for copper access services (ex: VDSL2/POTS), connect 25-pair twisted pair cables with RJ-21 connectors to the Champ connectors on the rear of the E7-2 unit(s).

Cable assignments

The image below shows the RJ-21 connectors (Champ) identified on the rear of the E7-2.

The table below lists the cable assignments for a single-slot VDSL2 Combo card.

Interface Cable

Equipment 1

Equipment 1

Equipment 2

1

1

2

Card RJ-21 ID

P1

P2

P3

Service

DSL/POTS

DSL/POTS

DSL/POTS

Protection Block

Location

1 (ports 1-24)

2 (ports 25-48)

3 (ports 1-24)

Equipment 2 2 P4 DSL/POTS 4 (ports 25-48)

The table below lists the cable assignments for a double-slot VDSL2 Overlay card.

Interface Cable

Equipment 1

Equipment 1

Equipment 2

Equipment 2

RJ-21 ID

P1

P2

P3

P4

DSL

DSL

POTS

POTS

Service Protection Block

Location

1 (ports 1-24)

2 (ports 25-48)

3 (ports 1-24)

4 (ports 25-48)

Subscriber

Ports

1-24

25-48

1-24

25-48

Subscriber

Ports

1-24

25-48

1-24

25-48

Guidelines

Calix recommends using CAT5 cables to achieve optimal Signal to Noise (SNR) margins and performance.

Calix recommends using 110-degree right exit Avaya 525e RJ-21 connectors on the

CAT5 cables to avoid interference with the cables and adjacent connectors. Using an RJ-

21 connector with a 90-degree exit on the back of the E7-2 shelf requires special attention. Only one side of the RJ-21 male connector can be secured with a screw; the other side of the connector must be secured with a cable tie wrap and cable tie mount

(provided by Calix in the E7-2 field install kit). The head of the cable tie must align with the bottom edge of the connector to achieve a robust connection.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

To wire out the E7-2 subscriber line interfaces

45

1.

Route the 25-pair equipment interface cables (RJ-21 connectors) to the rear of the E7-2 shelf.

2.

On the rear of the E7-2, terminate the interface cable(s) for slot 1 to the RJ-21 connector labeled P1 or P2 and the interface cable(s) for slot 2 to the RJ-21 connector labeled P3 or

P4, as required for the installed line card(s). See Cable assignments above for more information.

For an RJ-21 male connector with a 110-degree exit, do the following: a. Insert the RJ-21 male connector into the female connector on the back of the

E7-2 shelf. b. Tighten the screws on each side to secure the connector.

For an RJ-21 male connector with a 90-degree exit, do the following: a. Using a 4-40 screw, attach a cable tie mount to the right side of the shelf RJ-21 female connector as shown. b. Insert the RJ-21 male connector into the female connector on the back of the

E7-2 shelf. c. Secure the connector by tightening the screw at the bottom of the connector and attaching a tie wrap at the top of the connector.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

46

Note: To provide a securely mated connection, be sure to align the head of the cable tie along the bottom edge of the connector as shown. Failure to install the cable tie correctly may result in an inadequate connection.

3.

Dress the cable and secure them to the equipment rack (and cable tie bars) every 6–8 inches (15.24–20.32 cm) with cable ties or lacing cord.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

Chapter 5

Maintenance

This chapter describes how to perform routine maintenance on worn or failed E7-2 equipment.

Topics Covered

This chapter covers the following topics:

Replacing pluggable transceiver modules on E7-2 line cards

Replacing an E7-2 line card

Replacing the fan module

Fan filter maintenance

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

48

Replacing Pluggable Transceiver Modules

Use the following procedure to replace a damaged or failed pluggable transceiver module.

DANGER! CLASS 1 LASER PRODUCT. INVISIBLE LASER RADIATION

MAY BE PRESENT. Fiber optic radiation can cause severe eye damage or blindness. Do not look into the open end of an optical fiber.

To replace a pluggable transceiver module

1.

Disconnect the fiber(s) from the module to replace, if present.

2.

Remove the pluggable module from the E7-2 line card as follows: a. Unlock the latch on the module, if so equipped (latch styles vary). b. Gently pull the latch to unseat the module. c. Carefully slide the module out of the socket and set it aside.

3.

Insert a replacement module into the vacant socket and re-connect fibers. See

Connecting

the E7-2 Line Interfaces (on page 41 ) for detailed instructions.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

Replacing an E7-2 Line Card

49

Use the following procedure to replace a damaged or failed E7-2 line card.

ESD ALERT! Beware of electrostatic discharge. Follow standard ESD precautions. Always wear a grounded ESD wristband to avoid damaging the electronic equipment.

To replace an E7-2 line card

1.

Disconnect all line interface cables (fibers) from the card to replace.

2.

If the replacement card will reuse optics modules from the replaced card, remove all pluggable modules from the card.

3.

Remove the line card from the E7-2 shelf as follows: a. On the card faceplate, pull the ejector lever open into the unlocked position to unseat the card. b. Carefully slide the card out of the slot, and place it in protective packaging. Return the faulty unit to Calix.

4.

Insert a replacement line card into the vacant slot. See Installing E7-2 Line Cards (on page

26 ) for detailed instructions.

Note: If you are not installing a replacement card, or no replacement card is available, install a Blank card into the vacant slot.

5.

Install pluggable transceiver modules into the card and connect fibers as required. See

Connecting the E7-2 Line Interfaces (on page 41 ) for detailed instructions.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

50

Replacing the Fan Module

Calix E7-2 fan modules are hot-swappable, so you can remove and install the fan module while the system remains powered.

Calix offers two fan module types—FTA and FTA2 (as indicated on the fan module faceplate). FTA supports two fan speeds. FTA2 supports four fan speeds with E7 release 2.2 or higher; in releases prior to 2.2, FTA2 supports two fan speeds.

Note: Do not leave a powered E7-2 operating for more than a few minutes without a fan module installed, to avoid overheating the system.

Use the following procedure to replace a damaged or failed fan module. Return the faulty unit to Calix.

To replace the fan module

1.

Remove the fan module from the E7-2 housing as follows: a. Firmly grasp the fan module latch and slide it to the left, and then pull forward to unseat the module. b. Pull the fan module forward to remove it from the E7-2 chassis.

2.

Insert a new fan module into the vacant slot.

3.

Push the fan module back into the slot until the latch clicks into place, completely seating the module.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

Fan Filter Maintenance

51

The E7-2 fan module includes an air filter for use in indoor/office environments. The filter resides on the left side of the FTA, and on the right side of the FTA2.

The air filter is made of closed-cell fiber composite material and can be washed and replaced.

Calix recommends conducting a visual inspection of the filter every three months. When the filter becomes visibly clogged with dust or dirt, the filter must be cleaned.

Note: Do not leave a powered E7-2 operating for more than a few minutes without a fan module installed, to avoid overheating the system.

To clean the air filter

1.

Remove the fan module from the E7-2 housing as follows: a. Firmly grasp the fan module latch and slide it to the left, and then pull forward to unseat the module. b. Pull the fan module forward to remove it from the E7-2 chassis.

2.

Remove the air filter from the fan module (located on the left side of the FTA or on the right side of the FTA2).

Note: FTA2 is shown below.

3.

Clean the filter as follows: a. Using compressed air, spray the filter to remove loose dust particles from the surface. b. Thoroughly wash the filter in soapy water, removing any trapped dust/dirt particles.

Rinse the filter with water.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

52 c. Pat dry the filter using an absorbent towel or cloth. d. Spray the filter with compressed air to remove any remaining moisture on the outside of the filter.

Note: If the filter is badly worn, replace it with a new filter (available from Calix).

4.

Reinstall the filter into the fan module, and then install the fan module into the E7-2 chassis.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

Appendix A

Reference Information

This appendix provides general reference information about the Calix E7-2 Ethernet service access platform.

Topics Covered

This appendix covers the following topics:

E7-2 specifications

E7-2 LED behavior

RS-232 serial port pin assignments

Fiber handling techniques

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

54

E7-2 Specifications

Specifications for the Calix E7-2 follow:

Dimensions

Chassis

Weight

E7-2 chassis only

E7-2 chassis with FTA

E7-2 chassis with FTA + 2 line cards

E7-2 chassis with FTA2

E7-2 chassis with FTA2 + 2 line cards

Mounting

Width

Depth

Orientation

Electrical

Power input

Fusing

Environmental

Operating range

Storage range

Heat dissipation (with 2 line cards)

Fan module cooling capacity

Alarming

Compliance

Compatibility, Electrical Safety, and Electromagnetic emissions criteria

1.7 (H) x 17.5 (W) x 11.45 (D) inches

4.3 (H) x 44.5 (W) x 29.1 (D) cm

5.9 lbs (2.7 kg)

7.4 lbs (3.4 kg)

11.5 lbs (5.2 kg)

7.0 lbs (3.2 kg)

11.1 lbs (5.0 kg)

19-inch (48.26-cm) and 23-inch (58.42-cm) racks

Front (flush) mounting

Center (projection) mounting, 5 depth options

Horizontal and vertical mounting supported

-48 VDC redundant battery feeds (A and B)

-42.5 VDC to -72 VDC input range

7.5 Amps maximum (A and B)

-40º C to +65º C (-40º F to +149º F)

Humidity: 10 to 95% (non-condensing)

Altitude: up to 10,000 feet (3049 m)

-40º C to +85º C (-40º F to +185º F)

Humidity: 5 to 95%

Up to 185 Watts maximum

FTA: 200 Watts, 108 CFM; (2) automatic variable fan speed operations

FTA2: 200 Watts, 115 CFM; (4) automatic variable fan speed operations

Note: FTA2 requires E7 release 2.2 or higher to support four fan speeds. In releases prior to 2.2, FTA2 supports two fan speeds.

8 user definable alarm inputs (7 inputs, 1 output)

UL/cUL 60950

European Union EN 60950 (CE Mark)

EIA-310D

FCC Part 15 Class A

Network Equipment-Building System (NEBS) Level 3: Telcordia

GR-63-CORE

Telcordia GR-1089-CORE

Telcordia GR-3028-CORE

ETSI EN 300 019, ETSI 300 386

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

E7-2 LED Behavior

System status indicators

The Calix E7-2 fan module has four LEDs to indicate system alarm and operational status.

LED Name Color Status Description

CR Critical Red On A critical alarm is present in the system

Off No critical alarms are present in the system

MJ Major Red On

Off

A major alarm is present in the system

No major alarms are present in the system

MN Minor Amber On

Off

A minor alarm is present in the system

No minor alarms are present in the system

MGT System

Control

Green On An active E7-2 shelf controller (card) is present

Off No active E7-2 shelf controller (card) is present

Note: The E7-2 fan module also features a 7-segment LCD display (for future use).

Card status indicators

Each Calix E7-2 line card has three LEDs to indicate the card's operational status.

LED Name Color Status Description

FAIL Failure Red On A fault has occurred that should be addressed

Off Normal card operation

CTRL Control Green

Amber

On

On

This card is the active E7-2 shelf controller

This card is the standby E7-2 shelf controller

SRVC

Service Green On One or more ports are enabled and may carry services

Off No ports on this card are enabled

Note: LED behaviors are shown for the card's primary operational states. The card LEDs exhibit additional behaviors associated with boot up cycles and other activities. Refer to the

Calix E7 User Guide for full details.

55

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

56

Port status indicators

Each interface port on an E7-2 line card has an LED located below its module socket to indicate port status. (E7-2 cards contain a mix of some or all port types listed below).

LED Port Color Status Description

XFP

(1, 2)

10GE Green

SFP+

(1, 2)

SFP

(1–12)

GPON

(1–4)

GE

GPON

Red

Green

Green

On Indicates that an Ethernet link has been established

Blinking After module insertion, blinks (3) times to indicate the inserted module is recognized and allowed to operate

Blinks at variable speeds to indicate the link is transmitting/receiving traffic

Off Socket is vacant or an invalid module is inserted

On Indicates a module has been inserted into a 10GE socket that is directed to the backplane for connectivity between two cards

(Applies to XFP 2 and SFP+ 2 only)

Indicates that an Ethernet link has been established On

Blinking After module insertion, blinks (3) times to indicate the inserted module is recognized and allowed to operate

Blinks at variable speeds to indicate the link is transmitting/receiving traffic

Off Socket is vacant or an invalid module is inserted

On Indicates that at least one ONT is in service on the PON

Blinking After module insertion, blinks (3) times to indicate the inserted module is recognized and allowed to operate

Blinks steadily while the first ONT on the port is ranging

Off Socket is vacant or an invalid module is inserted

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

RS-232 Serial Port Pins

The E7-2 RS-232 serial port enables console connections to the E7-2 CLI, accessible via an

RJ-11 connector located on the E7-2 fan module (labeled MGT-4).

E7-2 Serial Port

RS-232 Signal

(From E7-2)

Serial Port

RJ-11F

TX

RX

GND

Pin 3

Pin 4

Pin 5

57

RJ-11F Connector

Calix offers an RS-232 console cable (DB-9F to RJ-11M) to connect a PC to the E7-2 serial port. Alternatively, you may use the pin assignments below to make your own console cable, as required.

Console Cable

RS-232 Signal

(From PC)

PC End:

DB-9F

E7-2 End:

RJ-11M

RX

TX

GND

Pin 2

Pin 3

Pin 5

Pin 3

Pin 4

Pin 5

DB-9F Connector

RJ-11M Connector

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

58

RJ-21 Pin Assignments

This topic provides the RJ-21 connector pin assignments. To wire the Calix E7-2 for DSx services (e.g., VDSL2/POTS), use 25-pair cables with an RJ-21 male connector. Calix recommends that the RJ-21 connector on the 25-pair cables use a 110 degree exit or 90 degree exit (at pins 1 and 26).

110-degree exit 90-degree exit

For instructions on installing an RJ-21 connector, see

Connecting to the Subscriber Interfaces (on

page 44 ).

Pin assignments

The E7-2 standard RJ-21 pinout assignments follow:

Pin Color Tip/Ring Circuit

1 BL/WH Ring 1

Pin

26

2 OR/WH Ring 2 27

3

4

5

6

7

8

9

10

11

GN/WH

BR/WH

SL/WH

BL/RD

OR/RD

GN/RD

BR/RD

SL/RD

BL/BK

Ring

Ring

Ring

Ring

Ring

Ring

Ring

Ring

Ring

3

4

5

6

7

8

9

10

11

28

29

30

31

32

33

34

35

36

Color

WH/BL

WH/OR

WH/GN

WH/BR

WH/SL

RD/BL

RD/OR

RD/GN

RD/BR

RD/SL

BK/BL

Tip/Ring

Tip

Circuit

1

Tip

Tip

Tip

Tip

Tip

Tip

Tip

Tip

Tip

Tip

8

9

6

7

10

11

2

3

4

5

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

12

Pin

13

14

15

16

17

18

19

20

21

22

23

24

25

Color

OR/BK

GN/BK

BR/BK

SL/BK

BL/YL

OR/YL

GN/YL

BR/YL

SL/YL

BL/VI

OR/VI

GN/VI

BR/VI

SL/VI

Tip/Ring

Ring

Ring

Ring

Ring

Ring

Ring

Ring

Ring

Ring

Ring

Ring

Ring

Ring

Circuit

12

13

14

15

16

17

18

19

20

21

22

23

24

Not used

Pin

37

38

39

40

41

42

43

44

45

46

47

48

49

50

Color

BK/OR

BK/GN

BK/BR

BK/SL

YL/BL

YL/OR

YL/GN

YL/BR

YL/SL

VI/BL

VI/OR

VI/GN

VI/BR

VI/SL

Tip/Ring

Tip

Circuit

12

Tip

Tip

Tip

Tip

Tip

Tip

Tip

Tip

Tip

Tip

Tip

Tip

13

14

15

16

17

18

19

20

21

22

23

24

Not used

59

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

60

Fiber Handling Techniques

Fiber splices must be created with utmost care to minimize optical link budget losses. To ensure fiber splices are within optical link budget loss specifications, follow the suggestions below.

Important: Calix strongly recommends using the fusion splice method for all fiber splices.

Jacket preparation (OSP fiber)

Remove the jacket, buffer tubes and strength member using a wire stripper or cutting pliers.

The plastic buffer coating should be removed with a high-quality wire stripper.

Fiber preparation

Proper preparation of the fiber end face is critical to any fiber optic connection.

Perpendicularity and end finish must be within allowable tolerances in order to minimize signal loss at these connections. A divergence of as little as 2° from perpendicular should be considered unacceptable. The end finish should have a smooth, mirror-like finish free of blemishes, hackles, lips, and burrs.

Ends should be prepared using the scribe and break method. While holding the fiber under slight pressure, run the cutting tool across the stationary fiber at a perpendicular angle.

Properly done, the cleave produces a perpendicular, mirror-like finish without hackles or lips.

If major flaws are noticed, the process must be repeated. Inspect the fiber end under a microscope to ensure proper finish.

Small scratches on the face or small pits on the outside rim of the cladding are common and should be considered acceptable. Fusion splicer readings and experience more than anything determines the definition of “small.”

Prior to putting the fiber ends into the fusion splicer, clean each end with pure optical grade isopropyl alcohol and a lint free pad such as Texwipe™ Alco Pad or Texwipe™ Cloth.

Making the splice

In the field, a single fiber is spliced using an LC connector (for Ethernet interfaces) or an

SC/UPC connector (for GPON interfaces). This connector must be purchased separately.

Insert both ends of the fiber to be spliced into the fusion splicer and follow the instructions as recommended by the manufacturer. Inspect the connection in the built-in viewer. The connection should appear to be seamless. Ensure that the signal loss on the display is.05 db or less. Coil the successful splice inside the splice tray, taking care not to exceed the bend radius parameters of the cable.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

61

Cleaning fiber optic connectors

The process described here should not be applied routinely. This procedure should only be performed in cases where degraded performance of the assembly is noted or there is evidence of contamination. Excessive cleaning may actually increase the likelihood of fiber contamination.

Materials used for cleaning fiber-optic devices should be consistent with the function. Wiping cloths should be made of lint free, non-abrasive materials. Cotton swabs should have a tightly wrapped tip and be talcum-free. Pure optical grade isopropyl alcohol is the recommended solvent for cleaning connector tips. For removing dust from receptacles, a canned compressed gas is recommended.

Cleaning procedures

Remove any accumulated dust or debris from the connector by blowing off the cylindrical and end-face surfaces of the connector using the compressed gas.

Use a pad or a wipe saturated with optical-grade isopropyl alcohol to gently wipe the cylindrical and end-face surfaces.

Use compressed gas to blow dry the connector surfaces or allow them to air dry.

Avoid touching the connector surfaces after cleaning. If the connector is not going to be used, it should be covered with a dust cap to prevent contamination.

Handling of connectors

Although ruggedly constructed, fiber connectors should be handled with care during insertion. Follow these tips to make secure, long lasting connections:

After removing the protective cap, make sure the fiber end remains clean and moisture free.

Insert the connector into the fitting by grasping the rigid plastic fitting directly behind the fiber output shroud. The connection is fully seated when you hear it snap (click) into place.

Never attempt to insert the connector by gripping the white or green flexible shroud.

This may cause the fiber to kink in the jacket, introducing unwanted noise to the line.

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

62

Proprietary Information: Not for use or disclosure except by written agreement with Calix.

© Calix. All Rights Reserved.

advertisement

Related manuals